1. Online 2 The pairing process starts Hold the credential at the lock or engage the magnet for the sensor to pair the hardware with the communication hub Lock Show a card to the Aperio lock and wait for visual indication from the lock s LED When the LED have stopped blinking ynu may click Done to see the pairing result Sensor Open the doorto activate the sensor Click Done afterward to see the pairing result Show card Engage sensor Time remaining until timeout 27 seconds 3 When the lock has stopped blinking you can click Done to see the pairing result Result The result is displayed Pairing result The result of the pairing request is presented below Communication hub paired successfully to 0148ED 4 Repeat this pairing process for all communication hubs and locks sensors within reach of the USB Radio Dongle Aperio Online Quick Installation Guide Document No ST 001322 A Date 8 juli 2013 11 Aperio Online 12 Step 4 Configuring locks and communication hubs Wizard This procedure describes a configuration example of locks and communication hubs using Override credential card secure communication and DIP Switch addressing mode For other settings and addressing modes refer to Aperio Online Programming Application manual ref 1 Before configuration check that Update device time during door configuration is activated Enter the Settings Installation Settings window
2. MIFARE UID format Select how the MIFARE UID shall be formatted in Audit Trails and when configuring Override Credentials Hexadecimal format i e 25A78FA4 Decimal format i e 631738276 Hexadecimal format reverse byte order i e A4BFA725 Decimal format reverse byte order i e 2760877861 Configuration wizard settings Follow the steps below to perform a default configuration of locks sensors and communication hubs The changes you make during the update of the door configuration are not carried out until you perform the device update on the last page in the wizard 1 Select a lock in the scan result table right click and select Lock Configure or Lock sensor Configure if several locks are paired TEILWNG N Aperio Fri Ap o Progra g A _ baa File Scan Settings Help Lock sensor Communication Hub EAC Address UHF Link Communication Hub 024521 Unknown MAC Address 00 17 7a 01 02 02 45 21 Physical i aulin sical Location Office A Firmware Flavor RS485 Multiple Lock Aperio protocol Lock sensor 0148ED Firmware Version 6 0 22795 Communication Hub 024521 gt Bootloader Version 4 2 5 Upgrade Firmware Radio protocol version 23 Channel 25 2 475 GHz Radio channels 11 16 25 PAN ID 4521 EAC addressing mode Legacy address offset DIP switch value 1 EAC Address DIP Switch Number of paired locks and sensors 4 Device Status EAC offline Lock
3. 1 Secure area communication error 0x0200 12 Secure area memory corrupt 0x0400 13 Secure area sensor or motor error 0x0800 14 Radio modem communication error 0x1000 15 Radio modem memory corrupt 0x2000 16 Radio modem configuration error 0x4000 17 Radio modem RF circuit error 0x8000 o If the battery is not accepted as new after a power on reset no POST is performed instead the 10 guick red flashes used to indicate Error in lock is shown Aperio Online Quick Installation Guide Document No ST 001322 A Date 8 juli 2013 Aperio M Online 5 Troubleshooting The tables below shows possible problems when using the Aperio technology and how to solve them During door installation and update Problem indication You are using a credential Use a credential that is not on the override configured as an override credential credentials list The lock sensor and the hub areon Check the radio channel settings for the lock sensor different radio channels and the hub so that they match Not possible to pair communication hub and lock sensor No default override credentials are configured for the installation Not possible to use override credentials Add the credentials one by one in the door configuration wizard You have not shown the credential to Perform device update again and show the credential The device update fails the lock within 30 seconds to the lock within 30 seconds During scanning Problem indi
4. Aperio Online Quick Installation Aperio M Online Table of Contents Introduction GYFFREDIN FYFYR NF YR Y 3 PUDO Sates ce SF FRY FREE ANN TR DA RYD FYNU TN DFTN NWY aa 3 SCO 3 APPICAPIEPIOdI burn 3 AbDreviatons and Delio 3 RATE S e E A E E E A EE A eee 3 E RR RTRT RR 4 WRU FPP VO Stia 4 The Aperio Programming Application FFR Y RYN TEN Y 4 Regulatory and security NOMI 4 Communication hub versions and EAC interfaCe essssssseseessessssseseeessssssssssesreresssssseserereressssssestrrseressssssssrrrrees 4 Quick Installation of Aperio lock and Communication HUD iiiin 5 Atomatic II 5 Paring with the Aperio Programming Application cccecsesssessessesssssscssessessssssessessscssessessessscsseesesssessesseeseesseens 6 EL E E a A TE I 20 Communication dip bd 20 Lock LED indications FY ax FT WN FENNI ION NN TF 21 lo cesello 22 PIENE 23 During door installation and update ssesessssooosessssssssssceessssssssseseeessrsssssssseresersssssssesttteeesssssssrereresesssseserrreressssss 23 OE SC aiar 23 Durno cani cura OT aera E OO A E E I EE EE 24 Darme cc I uu Mo SA ON FFR _ w e Oe A A RH FN FN 24 Aperio Online Quick Installation Guide Document No ST 001322 A Date 8 juli 2013 Aperio M Online 1 Introduction Purpose The main purpose of this manual is to provide necessary information for a guickinstallation of Aperio Online based products using the Aperio Online Programm
5. C addressing mode Legacy address offset Enable EAC Address via DIP Switch DIP Switch enabled 9 Click OK followed by Next in the wizard main window 10 Ifadvanced mode is activated the Advanced Settings and Advanced Lock Sensor Settings will appear Leave both pages without changes by clicking Next Aperio Online Quick Installation Guide Document No ST 001322 A Date 8 juli 2013 Aperio Online 11 On the Device Update page check that the summary of the configuration tasks that will be sent to the lock is correct Device Update The settings are now ready to be transmitted to Lock sensor You might need to Show card Engage sensor to Lock sensor Click Next The following updates will be transmitted to the Aperio Lock sensor Adding one override credentials Admin MIFARE Classic 25a78fa4 Security mode Customer Mode Time and date Current system time 12 Click Save configuration to facilitate further lock configurations for other hubs locks using the same communication hub Enter a configuration name and click OK Save configuration to local storage Selectthe configurations in the table below that you want to save Then choose a name for the setting and click OK to save Configuration name Standard lock configuration Include configurations Adding one override credentials Security mode Time and date 13 Click Next in the wizard main wi
6. Succeeded Adding one override credentials Time and date 5 Repeat the configuration for all locks paired to the communication hub 6 Finally activate customer mode for the communication on the right click menu Communication hub Switch to customer mode File Scan Settings Help Communication Hub EAC Address UHF Link Unknown Security mode conflict Communication Hub 024521 Manufacturer Mode Lock sensor 0148E8 Customer Mode ub 024521 Communication Hub 024521 gt Apply configuration 00 17 7a 01 02 02 45 21 Office A RS485 Multiple Lock Aperio protocol 6 0 22795 a Configure Upgrade Firmware Pair with lock or sensor Retrieve system information Change radio channels 1 2 5 Change EAC Address i 23 Change physical location name 25 2 475 GHz Switch to Customer Mode 11 16 25 PAN ID 4521 EAC addressing mode Legacy address offset DIP switch value 1 EAC Address DIP Switch Number of paired locks and sensors 2 Device Status EAC offline Lock sensor 0148E8 MAC Address 00 17 7a 01 02 01 48 e8 Assigned Address 0x1350 EAC Address 2 Radio protocol version Unknown USB Radio COM 7 July 2 2013 3 03 56 PM 18 Aperio Online Quick Installation Guide Document No ST 001322 A Date 8 juli 2013 Aperio M Online Step 6 Testing after configuration Follow these steps to test that the installation and first configuration of each communication hub
7. and lock has been performed correctly and that the hardware is working 1 Check that the communication hub LED has a steady green light if connected to EAC This indicates that the installation and configuration have been performed correctly Online Gi Green 2 Hold a credential configured in the EAC in front of the lock Result Access is denied and the lock LED flashes red once Access denied MARI One red flash EAC online A 1 second 3 Hold a credential configured in the EAC in front of the lock Result Access is granted and the lock LED flashes green once See next chapter for details on the LED indications for communication hub and lock Access granted di One green flash EAC offline or online aT 1 second Aperio Online Quick Installation Guide Document No ST 001322 A Date 8 juli 2013 19 Aperio Online 4 LED Indications Communication Hub LED indications The communication hub has a single LED It supports an optical scheme with red green and yellow The indication scheme is described by the two figures below 2 SEC Figure 2 Communica TO FF tion hub normal op eration LED indication Online GE Green Aperio lock ria Green one _ UN o G offline d red flash Green two b N ITN ae O EAC offline meo Green three red flashes Aperio lock and Co Ox 80 Oe gt gt EAC offline DOS d n ie UHF NWrboel
8. cation The communication hub All channels are busy Repeat the scanning process by selecting and lock sensor are not found when scanning no connection between the Programming Application laptop and the communication hub None or not all of the communication hubs are found when scanning n a is shown for the installation in the communication hub field and in the Lock sensor field of the scan result table Unstable communication between communication hub and lock sensor even though the MAC address is displayed at scan The communication hub is not working The communication hub is not powered The communication hub s are out of range The communication hub s are not powered Too many communication hubs are using the same channel i The communication hub and or communication hub paired with a lock sensor belongs to another installation and has another encryption key The lock sensor is not paired with the communication hub A probable cause is bad radio conditions or limited radio range Scan Scan all Change the radio channel See the Programming Application manual ref 1 Repeat the scanning process by selecting Scan Scan all Change the radio channel See the Programming Application manual ref 1 Temporary reduce the number of powered up Hubs within radio range during configuration Switch installation or create a new installation with the corre
9. cation hubs within reach of the USB Radio device of your computer are displayed in the scan result table Select the Communication Hub to retrieve detailed information from Checkthe boxes for each Communication Hub and press Show details to retrieve detailed information To select all click in the checkbox in the title row or press Ctrl A or Ctrl Communication Hub Radio channels UHF Link 12 16 24 wv Ss 15 20 13 18 23 14 19 25 lit 16 25 11 16 25 lit 16 26 12 25 lis 20 lis 20 13 23 s T lo o EB 2 Locate a communication hub by the last four characters of the communication hub MAC address ex 01CF in the scan result table The same characters should be on a label on the cover of the communication hub Click Rescan if the communication hubs that you want to configure are not shown in the list Aperio Online Quick Installation Guide Document No ST 001322 A Date 8 juli 2013 9 Aperio Online 10 3 Select the communication hub s that you want to include in your installation Click Show details to view detailed information in the installation view gwa File Scan Settings Help Lock sensor Communication Hub EAC Address UHF Link 0216F1 Unknown IL Not paired with any device a8 a 024521 Unknown 000 A Communication Hub 0216F1 not paired with any device Communicat
10. ct encryption key Pair the lock sensor and communication hub in the Configure door wizard of the Programming Application Try moving the USB radio closer to the communication hub or moving the USB radio to a higher location Either by moving the laptop or by using an A A USB extension cable to distance the USB radio from the PC 1 Aperio Hubs are default configured to select the best channel out of three possible if the selected channel is disturbed a new channel selection will be done automatically Communication hubs in an Aperio system normally distribute themselves on different channels but a synchronized power up of all Hubs may cause them to initially choose the same channel Note that this problem does not affect performance of already installed and paired lock cylinders sensors and Hubs only Programming Application scan functionality is affected Aperio Online Quick Installation Guide Document No ST 001322 A Date 8 juli 2013 23 Aperio M Online 24 During configuration Problem indication The program application reports an update failure The device does not support the desired configuration The firmware on the device is outdated During normal operation Problem indication The communication hub LED is flashing red once no connection between the lock sensor and the communication hub The communication hub LED is flashing red twice no connection between the EAC system and the communica
11. dentials wirelessly to the Communication Hub and the Communication Hub wired through RS 485 or Wiegand then communicates with an EAC Electronic Access Control system The EAC system then makes the access decision The decision is sent via the Communication Hub to the lock and access is granted or denied The Aperio Programming Application The Programming Application is used for the configuration of a door installation It is installed on a laptop The laptop has an Aperio USB radio device connected to one of its USB ports The USB radio device enables the application to connect via a Communication Hub to the door lock The lock communicates via the Communication Hub either with the EAC or with the Programming Application Read more in the Aperio Online Programming Application Manual RS 485 RNA or Wiegand EAC system Electronic Access Control Regulatory and security information Refer to the Programming Application manual for regulatory and security information Communication hub versions and EAC interface There are four communication hub types according to the table below Maximum number of Version Interface locks units AH15 Wiegand RS 485 1 AH20 Wiegand 1 8 1 AH30 RS 485 EAC address EAC address 1 15 15 63 The firmware type loaded into the communication hub controls what interface is enabled Aperio Online Quick Installation Guide Document No ST 001322 A Date 8 juli 2013 Ap
12. e MIFARE Classic UID The UID is entered using hexadecimal format For example 25A78FA4 2SA78FA4 Aperio Online Quick Installation Guide Document No ST 001322 A Date 8 juli 2013 13 Aperio M Online 14 5 Click OK followed by Next in the Wizard main window 6 On the Security mode Setting page click Change to switch to Customer mode in both the lock and communication hub to obtain secure communication using the Encryption key Configure Lock sensor 0148ED Es Security Mode Setting Set the security mode that will be used for encrypted radio communication Click Next to continue Security Mode Setting Security mode will not be changed 4 Back gt Next Cancel Proper handling of Encryption keys is essential to lock sensor security o If the installation and first configuration is not performed correctly by setting all locks in customer mode the radio communication will not be secure and the locks will therefore be vulnerable to intrusion attempts 7 To enable secure communication using the encryption key select Switch to customer mode in device click OK and then Nextin the wizard main window 8 On the Electronic Access Controller Setting page in the Enable EAC Address via Dip Switch field click Change and select Enable Dip Switch 4 Configure Lock sensor 0148ED Electronic Access Controller Settings Change settings if needed Click Next to continue EA
13. e Programming Application SA Aperio Programming Application File Scan Settings Help New Ctrl N Open Ctrl O Export Import Configurations Exit Ctrl F4 2 Entera name for the installation and click the button in the Key file field to add the Encryption key Installation Enter installation name and key file ep new installation Key file File i 3 Select the key file and click Select The xml file key file containing the encryption keys should be delivered via encrypted e mail or on a USB memory stick 4 Click Create new Installation Enter installation name and key file Installation name new_ installation rKey file File Socuments My Dropbox Assa Abloy Aperio Mjukvarallicence file xml Cancel Aperio Online Quick Installation Guide Document No ST 001322 A Date 8 juli 2013 Aperio Online 5 Enter a password of at least 8 characters for the door installation and confirm it Click OK Password Please enter a password for the new installation The password must contain at least 8 Password eoeoeee Confirm password eeccccece Step 2 Scanning for Communication hubs Follow these steps to scan for doors 1 Select Scan Quick scan to find communication hubs Or open a earlier created installation Result All communi
14. erio M Online 3 Quick Installation of Aperio lock and Communication Hub A guick installation of Aperio lockand Automatic pairing The communication hub communication hub starts with pairing the automatically pairs with nearby Aperio lock hardware In some cases lock communication sensor hub are pre paired from the factory If not Pairing with the Aperio Programming pairing can be done in two ways Application The pairing is manually performed which gives access to detailed settings and encrypted communication Automatic pairing Automatic pairing is obtained by setting the DIP Switch in Pairing mode refer to the Mechanical installation manual communication hub manual Automatic pairing will only be made with unpaired locks Communication hub and locks are often sold pre paired from factory If this is the case the following pairing procedure is not necessary However configuration using the Aperio Pro gramming Application is still needed To perform pairing with communication hubs set in Pairing mode do the following 1 Power cycle the communication hub if necessary and check that the LED is constant yellow Pairing active Ge Yellow 2 Hold the credential in front of the lock to activate it or engage the magnet for the sensor Result Communication hub pairs with lock and indicates with one green flash P NE Yellow SSS SSS Pairing succeded one green flash 3 After successful paring power of
15. f the Communication hub 4 Set the DIP switch 1 5 to desired RS 485 address 1 15 for communication hubs with one or several locks paired 1 31 for communication hubs with one lock paired This will also deactivate pairing mode For devices operating in Wiegand mode set the DIP switch 5 to OFF to turn off Pairing mode 5 Powerthe communication hub to start up for normal operation i Locks sensors and communication hubs that are paired with pairing mode will communi cate in Manufacturer mode It is required to activate Customer mode by using the Program ming Application when finalizing according to next section to obtain encrypted communi cation Aperio Online Quick Installation Guide Document No ST 001322 A Date 8 juli 2013 5 Aperio M Online Paring with the Aperio Programming Application The Programming Application is used to access detailed settings and encrypted communication Customer mode during the pairing process of locks sensors and communication hubs Using the Programming Application also allows you to establish encrypted communication between locks sensors and communication hubs This is achieved with a customer key obtained from your ASSA ABLOY supplier This chapter describes a complete installation applicable for most EAC system using a standard configuration To communicate with communication hubs and locks sensors through the Programming Application you also need an USB Radio dongle For ins
16. ing Application The manual is intended for installation personnel project managers and people with similar responsibilities Scope This quick installation guide covers a standard installation of a complete Aperio online system including communication hubs and locks Sensors For a complete description of all functionality and possible settings in an Aperio online installation refer to the Aperio Online Programming Application Manual ref 1 This manual is applicable to version 2 6 4 of the Aperio Online Programming Application Abbreviations and Definitions Applicable Products This manual can be used for all versions of communication hubs Abbreviation Definition EAC Electronic Access Control The system controlling access decisions DIP Dual in line Package A manual electric switch used for settings on the communication hub RFID Radio Frequency Identification The credential technology used References 1 ST 001323 Aperio Online Mechanical Installation Manual 2 ST 001321 Aperio Online Programming Application Manual Aperio Online Quick Installation Guide Document No ST 001322 A Date 8 juli 2013 Aperio M Online Figure 1 Aperio technology overview 2 System Overview Programming application ZA IEEE802 15 4 2 4GHz ff Communication Hub The Aperio system The Aperio system is used in the following way The user holds an RFID card in front of the lock The lock sends card cre
17. ion Hub 0216F1 MAC Address Firmware Flavor Firmware Version Bootloader Version Radio protocol version Channel Radio channels PAN ID EAC addressing mode DIP switch value EAC Address Device Status USB Radio COM 10 Step 3 Pairing locks sensors with communication hub AH30 version of the communication hub can be paired with a combination of up to 8 locks sensors AH15 AH20 can manage one lock sensor 00 17 7a 01 02 02 16 f1 RS485 Aperio protocol 6 0 22795 1 2 5 23 19 2 445 GHz 14 19 25 16F1 Hormal address offset 1 DIP Switch EAC offline May 28 2013 4 32 18 PM 1 Right click and select Communication hub Pair with lock or sensor ee File Scan Settings Help I Lock sensor Communication Hub EAC Address UHF Link Unknown o a Not paired with any device Fi bebe mie Communication Configure r Hub 024521 Communication Hub 024521 gt Pair with lock or sensor Upgrade Firmware Retrieve system information Office A Change radio channels Change EAC Address Change physical location name Switch to Customer Mode TT channel 25 2 475 GHz 11 16 25 4521 1 DIP Switch EAC offline 00 17 7a 01 02 02 45 21 Hub 024521 not paired with any device Legacy address offset Aperio Online Quick Installation Guide Document No ST 001322 USB Radio COM 10 May 28 2013 4 44 30 PM A Date 8 juli 2013 Aperio
18. munication hubs Step 3 pairing with locks sensors Step 4 configuring locks and communication hubs setting security mode addressing mode override credentials etc Step 5 Apply saved configuration on several locks Step 6 testing after configuration For some configurations a number of additional advanced settings can be necessary such as configuration of status and alarm messages configuration of the radio communication These and a number of other advanced settings are described in the Aperio Online Programming Application manual ref 1 The quick installation process does NOT i require that the EAC is connected to the Aperio hardware Quick installation can be performed on hardware not yet mechanically installed Aperio Online Quick Installation Guide Document No ST 001322 A Date 8 juli 2013 Aperio Online Preparation before guick installation Install the Programming Application and USB Radio dongle drivers on your laptop Refer to ref 2 Aperio Online Programming Application manual for instructions Make sure the communication hub is powered 8 24V and that batteries are installed in the lock Step 1 Making a new door installation The first step is to create a new door installation which will handle all the communication hubs and Aperio locks sensors in the access control system Insert the USB Radio dongle and start the Aperio Programming Application 1 Select File New in th
19. ndow to download the configuration to the lock Aperio Online Quick Installation Guide Document No ST 001322 A Date 8 juli 2013 15 Aperio Online 14 If necessary hold the credential in front of the lock to activate the radio Device update result The result ofthe device update will be presented below Waiting for user to Show card Engage sensor Show card Engage sensor Time remaining until timeout 14 seconds a a 4 Back amp Close Cancel 15 After successful update click Close Device update result The result ofthe device update will be presented below Successful 2 Adding one override credentials 2 security mode 2 Time and date EN Using the wizard for a communication hub with only one lock paired customer mode is set both for the lock and communication hub For communication hubs with several locks paired a security conflict will appear 16 Aperio Online Quick Installation Guide Document No ST 001322 A Date 8 juli 2013 Aperio Online Step 5 Apply saved configuration on several locks If you have more than one lock that will use the same configuration you can apply the recently saved configuration on any lock in your installation 1 Right click on a lock and select Lock sensor Apply configuration your configuration x Poni Ges File Scan Settings Help EAC Address Unknown Lock sensor Communication Hub Lock sens
20. or 0148E8 UHF Link Communication Hub 024521 Apply configuration 00 17 7a 01 02 02 45 24 Office A Standard lock configuration Communication Hub 024521 Upgrade Firmware USB Radio COM 7 The following settings will be transmitted to Lockjsensor You might need to Show card Engage sensor to Lockfsensor Click Confirm to proceed Adding one override credentials Admin MIFARE Classic 25a78fa4 Security mode Customer Mode Time and date Current system time Configure Retrieve system information Get Event Log Get Audit Trail Change radio channels Switch to Customer Mode Change physical location name Unpair lock sensor from communication hub Tumber of paired locks and sensors Device Status Lock sensor 0148E8 MAC Address Assigned Address EAC Address Radio protocol version 2 Confirm the update by clicking Confirm 6 0 22795 1 2 5 23 25 2 475 GHz 11 16 25 4521 Legacy address offset 1 DIP Switch 2 EAC offline 00 17 7a 01 02 01 48 e8 0x1350 2 Unknown July 2 2013 2 53 34 PM 3 Hold the credential in front of the lock sensor to download the configuration Show card Engage sensor Time remaining until timeout 14 seconds a a Aperio Online Quick Installation Guide Document No ST 001322 A Date 8 juli 2013 17 Aperio Online 4 After successful update click Close
21. r in lock indication is also shown instead of the POST flashes if the battery is not accepted as new after a power on reset Some special LED indication schemes are used during lock maintenance actions Figure 5 Lock hub Enter configuration setta Five yellow flashes e e ai sia mode 7 7 gt 7 7 gt 7 gt 125 second each Aperio Online Quick Installation Guide Document No ST 001322 A Date 8 juli 2013 21 Aperio M Online Figure 6 Lock POST LED indication 22 Lock self test LED indication After replacing the battery a Power on Self Test POST is performed The result is indicated using a series of red and green LED flashes as is described by the figure below Sire MIL One red one green flash POST Successful 7 gt 1 second i alii _ One red flash followed by 16 Failure during POST cin AN AN AN AN ne AN red or green flashes 5 second The first flash is always red If the POST fail the color of the 16 trailing flashes indicate the status of each individual test as described by the following table Blink Meaning if red Code in event log 2 Main board firmware corrupt 0x0001 3 Override list corrupt Ox0002 4 Production data corrupt _ 0x0004 5 Security data corrupt 0x0008 6 Configuration data corrupt 0x0010 7 Load Circuit Error 0x0020 8 Configuration data corrupt2 0x0040 9 Secure Area Encryption Key error 0x0080 10 Secure Area Motor error 0x0100 1
22. sb 90 0007 Yellow off communication A iSM V 1 VYV 1 v 1 v 1 gt fast flash Some special LED indication schemes are used during lock maintenance actions 2 Sec Figure 3 Communica r I Pairing active Y a Yellow green tion Hub maintenance LED indication 20 Aperio Online Quick Installation Guide Document No ST 001322 A Date 8 juli 2013 Aperio M Online Lock LED indications The lock has three LEDs They support an optical scheme with red yellow and green The indication scheme is described by the figures below Figure 4 Lock normal Card read up One yellow flash operation LED indica configurable 29 25 second tion Access granted its One green flash EAC offline or online aR ite 1 second Force closed in remote _ il i il 4 Five yellow flashes and openfoffice mode _ ___0___0___0___ e one red flash 25 second Busy blink com hub i12 i it Continuous yellow flashes __ e o eo busy with other locks gt 75 ai 71 25 seconds every second Access denied ait One red flash EAC online a 1 second Access denied wii alia ddl Three red flashes EAC offline ____ 5 second each Lock mechanismis Ii Qi 1 IL ts Continuous red flashes blocked when closing _0________o____ 125 seconds every 1 sec o 1 When the lock mechanism is blocked lock jammed the knob must be turned to release it o 2 The Erro
23. sensor 0148ED MAC Address 00 17 7a 01 02 01 48 ed Assigned Address 0x1307 EAC Address 1 Radio protocol version 23 USB Radio COM 7 July 2 2013 2 29 03 PM Aperio Online Quick Installation Guide Document No ST 001322 A Date 8 juli 2013 Aperio Online 2 On the RFID Configuration page click Next without any changes RFID Configuration Note that current RFID configurations in the Aperio lock are not displayed Selectthe RFID type you want to configure from the tabs below MIFARE Plus DESFire Low frequency Chanaes to be sent Remove changes 3 If advanced mode is activated the Keypad configuration page will appear Leave without changes by clicking Next 4 On the Override Credential page it is recommended to add a credential Select the credential type in the drop down list and click Add and enter credential information in this case MIFARE Classic UID This credential can for example be used to gain access through all doors during installation and when the EAC is offline Add and replace override credentials fno changes are made the credentials in the lock will be let unchanged Note that the list below does not show credentials currently loaded into the lock Ifyou load new cards into the lock the old cards are replaced Click Nex to continue Enter new override credential Enter UID for the credential You may also enter a description of the credential Card Type Card Typ
24. tallation of the Programming Application and the USB Radio dongle refer to the Aperio Online Programming Application manual ref 1 Information of encryption key To obtain secure communication between communication hubs and locks sensors an Encryption key is used This Encryption Key should be handled with the same care as the Master Key in a traditional Master Key System A person with access to the Encryption key can gain unauthorized access to any Aperio door in the system Once loaded into the Programming Application it will be stored encrypted in a local database and should be erased from the hard drive A copy should be stored safely Proper handling of encryption keys is essential to lock sensor security It is absolutely necessary to use the customer encryption key by setting all communication hubs and locks sensors in Customer mode to ensure a secure and encrypted communication with the lock sensor Aperio Online Quick Installation Guide Document No ST 001322 A Date 8 juli 2013 Aperio M Online Checklist for pairing and configuration of locks sensors and communication hubs Figure 1 Eguipment needed Communication hub Programming application SS Tritech TriBee lid GP USB dongle lt gt RFID card A complete configuration includes the following steps Preparation Installation of software and powering the Aperio hardware Step 1 making a door installation Step 2 scanning for com
25. tion hub Unstable radio communication between lock sensor and communication hub The lock sensor and communication hub are not paired The lock sensor and the communication hub have different channel masks The battery of the lock sensor has run out The EAC address is not properly configured in the communication hub The EAC system is not properly configured Poor radio link quality The lock sensor and the communication hub have different channel masks Check the current firmware on the device and perform an upgrade if needed Also check the intended new configuration Repeat the scanning process by selecting Scan Scan all Pair the lock sensor and communication hub in the Configure door wizard of the Programming Application Change the radio channel See the Programming Application manual ref 1 Change the battery of the lock sensor See the Programming Application manual ref 1 Configure the EAC address Refer to the Aperio mechanical installation manual Change the radio channel See the Programming Application manual ref 1 Aperio Online Quick Installation Guide Document No ST 001322 A Date 8 juli 2013 Aperio M Online Aperio Online Quick Installation Guide Document No ST 001322 A Date 8 juli 2013 295 ASSA ABLOY is the global leader in door opening solutions dedicated to satisfying end user needs for security safet
26. y and convenience assaabloy com aperio Contact Sweden Finland Wireless a lock aper lO technology N ASSA ABLOY AB Box 70340 107 23 Stockholm Visiting address Klarabergsviadukten 90 Phone 46 8 506 485 00 ABLOY OY Wahlforssinkatu 20 80100 JOENSUU Phone 358 20 599 2501