1. 220VAC 48VDC E1 Port 75 1200hm Ethernet Port Power IN Power IN Selection Figure2 Back Panel of Standalone Note 220VAC amp 48VDC power input are alternative in one device there is only one kind of power input Z Fibridge F4 51 Converter User Manual V2 0 4 3 Front Panel of Module Figure3 Front Panel of Module Z Fibridge F4 51 Converter User Manual V2 0 4 4 LED Description Table 1 LED Description Indicator Color Status Description RXD Yellow Blink Receiving data TXD Yellow Blink Transmitting data LINK Green ON Ethernet port link OK Ethernet is working at Full FDX Green ON Duplex mode LOS Red ON E1 link signal loss LOF Red ON E1 synchronization loss COL Red ON Ethernet line collision LOOP Green ON Indicate Local Loop Status POWER Green ON Power supply OK 4 5 DIP Switch Description Refer to the following tables for the functions of the DIP switches located along the both of the front and back side of the F4 51 F4 51 provides a total of 5 DIP switches for timeslot selection see table 2 for detail But please NOTE when you select unframed mode set pin 7 of SWITCH1 ON the timeslot setting does no function Fractional E1 uses only a fraction of the total available timeslots For example if you wish to translate only 192K from a 2048K E1 line you only need to set two pins pin1 and pin2 8 Z Fibridge F4 51 Converter User M
2. Descriptions LP Mode JP5 Description Up ene Remote Loop only available on Fractional framed Mode Down 2 3 short Local Loop 10 Z Fibridge F4 51 Converter User Manual V2 0 Explanation 1 UP is corresponding to Down is corresponding to 2 Short is corresponding to Sel 1 2 3 1 2 3 1 2 short 2 3 short NOTE 1 Before you select remote loop or local loop you should set E1_LP down first 2 Local Loop Back is available both in framed mode and in unframed mode 3 Remote Loop Back is only available in framed mode In other words if you want to use remote loop you should set the bit7 of SWITCH on the front panel of the device ON see table 2 of the technical datasheet 4 f Unit A F4 51 is at internal clock Unit B F4 51 is at recovered clock and there is no other based clock in the whole network line you can t set Unit B F4 51 on remote loop 5 Unit A s local loop back OUT IN erme IN OUT Unit A s remote loop back OUT IN OMA erme unte IN OUT 11 Z Fibridge F4 51 Converter User Manual V2 0 4 6 Bandwidth Selection Table 6 Bandwidth Selections No Bw4 BW3 BW2 BW1 BWO Bandwidth 1 ON ON ON ON ON N A 2 ON ON ON ON OFF 64Kbps 3 ON ON ON OFF ON 128Kbps 4 ON ON ON OFF OFF 192Kbps 5 ON ON OFF ON ON 256Kbps 6 ON ON OFF ON OFF 320Kbps 7 ON ON OFF OFF ON
3. Z Fibridge E1 Framed unframed 75ohm 120ohm Compatible F5 4511 Series Ethernet to E1 Converter F4 51 User Manual Version 2 0 BEIJING FIBRIDGE CO LTD Z Fibridge F4 51 Converter User Manual V2 0 Table of Content ECL 3 2 Features 3 3 Specification eese 4 SA CIC T 4 3 2 Ethernet Interface mrararnornnrnnnvnnnnrnarennernnnennennrnnne 4 SEIEN 5 RI MEE 5 3 5 Environment 5 4 AppearaNCce serrunssvvnnnnnnvnennnnnnnvnnnnnnnenennnnnnennnnnnnenennunne 6 4 1 Front panel of standalone n 6 4 2 Back panel of standalone 6 4 3 Front Panel of Module sesers 7 44 JEED DeSCrptlOn iiiter tetuer e 8 4 5 DIP Switch Description eeeeeeeeeeee 8 4 6 Bandwidth Selection eneee 12 5 Typical Application eene 13 5 1 Point to Point ssssssssssseseeeemenn 13 5 2 Star Topology 14 6 Order Information eene 14 bl Model EE 14 02 PN ee 14 Z Fibridge F4 51 Converter User Manual V2 0 1 Overview F5 4511 Series F4 51 converter is a high performance remote self learning Ethernet bridge Its compact size and low cost make it ideal for cost sensitive bridging applications or as a LAN extender over bit stream type infrastructures Its E1 data interface also provides an economical digital access solution for E1 and Fractional E1 n
4. 384Kbps 8 ON ON OFF OFF OFF 448Kbps 9 ON OFF ON ON ON 512Kbps 10 ON OFF ON ON OFF 576Kbps 11 ON OFF ON OFF ON 640Kbps 12 ON OFF ON OFF OFF 704Kbps 13 ON OFF OFF ON ON 768Kbps 14 ON OFF OFF ON OFF 832Kbps 15 ON OFF OFF OFF ON 896Kbps 16 ON OFF OFF OFF OFF 960Kbps 17 OFF ON ON ON ON 1024Kbps 18 OFF ON ON ON OFF 1088Kbps 19 OFF ON ON OFF ON 1152Kbps 20 OFF ON ON OFF OFF 1216Kbps 21 OFF ON OFF ON ON 1280Kbps 22 OFF ON OFF ON OFF 1344Kbps 23 OFF ON OFF OFF ON 1408Kbps 24 OFF ON OFF OFF OFF 1472Kbps 12 Z Fibridge F4 51 Converter User Manual V2 0 25 OFF OFF ON ON ON 1536Kbps 26 OFF OFF ON ON OFF 1600Kbps 27 OFF OFF ON OFF ON 1664Kbps 28 OFF OFF ON OFF OFF 1728Kbps 29 OFF OFF OFF ON ON 1792Kbps 30 OFF OFF OFF ON OFF 1856Kbps 31 OFF OFF OFF OFF ON 1920Kbps 32 OFF OFF OFF OFF OFF 1984Kbps 5 Typical Application 5 1 Point to Point Et Line 0 In the above application it is recommended that user select one F4 51 device s timing signal as unique timing source and all the other equipment follow this timing source F4 51 should be used in pairs 13 Fibridge F4 51 Converter User Manual V2 0 5 2 Star Topology i Ethernet Switch Converter 16 slot E1 Channel is Data Center User End 6 Order Information 6 1 Model F5 4511 Ethernet to 1
5. 8 E1 Protocol Converter Series 6 2 P N F4 51A 10Base T to E1 Converter Standalone Device 220VAC Power input F4 51D 10Base T to E1 Converter Standalone Device 48VDC Power input F4 51M 10Base T to E1 Converter Module Card FC 416 16 Slots Chassis Supply two Powers 14
6. anual V2 0 of SWITCH1 OFF and set three pins pin3 5 of SWITCH1 ON Table 2 Function Description of Switch SW5 BIT Status ITEM Switch SW5 ON OFF 1 8 BWo BWO BWA are used as Binary Code and can provide 32 different kinds of 2 7 BW1 Bandwidth BWA is the MSB BWO is the LSB When 3 6 BW2 is ON it means 0 when is OFF it means 1 4 5 BING See Table 6 to get more details These settings will be ignored when 5 4 BW4 Bit7 Full Fabr is set OFF 6 3 NA Not Available Not Available Framed Fractional Unframed Full 7 2 E1 FULL mode mode 8 1 TIM MOD Recovered Clock Internal Oscillator Note Switch is for standalone and SW5 is for module Z Fibridge Table 3 75 1200hm selection or SW6 Setting F4 51 Converter User Manual V2 0 BIT For 75 ohm Selection For 120 ohm 1 OFF ON 2 ON OFF 3 ON TRIP connected to ground OFF OFF TRIP is opened 4 ON RRIP is connected to ground OFF OFF RRIP is opened Default Bit 1 4 OFF ON ON ON Note 75 1200hm Selection is for standalone and SWe is for F4 51 module Card Table 4 E1 LP Button or JP4 Jumper Descriptions E1 LP JP4 Description Up 2 3 short None loop work as normal Loop mode usually used to check the fault of the network line To Down 1 2 short configure either Local loop or Remote loop please see table 5 Table 5 LP MODE Button or JP5
7. etwork Services which can work at data rates of 64Kbps to 2048Kbps User data is placed into the E1 frame using only the required number of timeslots Timeslot assignment is accomplished according to the Data Port speed and manual setting of DIP switches The main E1 link may be clocked from the recovered receive clock or from an internal oscillator For easy to check the fault of network line the device provides loop selection both local loop and remote loop 2 Features e High performance bridge for 10Base T Ethernet extension Fully compatible with IEEE 802 3 and Ethernet Standards E1 channel framed and unframed optional 75 1200hm optional e Ethernet Port 10Mbps Full Half Duplex Mode compatible e 10Base T LAN Interface on RJ 45 connector and 3 Z Fibridge F4 51 Converter User Manual V2 0 oO 999999 o MDI MDI X optional Allow transmitting and receiving VLAN data packet 15000 frames per second filtering and forwarding rate 1000 MAC address LAN table and automatic LAN table learning and aging Standalone and 16 slots chassis optional Power of Chassis 2 Slots for slide in power supplier module AC or DC power supplier module Redundant Power supported Specification 1 E1 interface Data rate N 64Kbps N 1 32 Code type HDB3 Compliant with G 703 G 704 Line impedance 75 2 Unbalanced 120 9 Balanced Connector BNC 75 9 RJ45 120 9 Jitter Compliant with ITU T G 742 and G 823 Framed unframed o
8. ptional Definition of RJ45 connector 1209 E1 balanced PIN 1 2 4 5 3 6 Others Function TX TX RX RX GND Reserved 3 2 Ethernet Interface Compatible with IEEE802 3 Speed 10Mbps 4 Z Fibridge F4 51 Converter User Manual V2 0 Full Half duplex auto negotiate Connectors RJ 45 Connector e Transfer distance 150m 3 3 Size e Standalone 252 W xX 136 D 40 H mm Module 220 L x 176 W X25 3 H mm 16 slot chassis 19 inch W x 340mm D X 4U H 3 4 Power Power supply AC Power 100V 240V 0 4 0 2A 50 60 Hz DC Power 48V 0 4A Power consumption 3W 3 5 Environment Operation Temperature 0 C 50 C Humidity 90 non condensed Air pressure 86kPa 106 kPa Transport and store Temperature 20 C 60 C Humidity 95 non condensed Air pressure 86kPa 106 kPa Z Fibridge F4 51 Converter User Manual V2 0 4 Appearance 4 1 Front panel of standalone oven EKLP LPANOD RESET PXO TXO LINK FOX LOS LOF COL LOOP POWER B on ribridge HATER 000000000 7 OOo on E1 Ethemet Converter DIP Switch LOOP Button LED Power Switch Figure1 Front Panel of Standalone 4 2 Back panel of standalone AC 120000 ESN DC IN meran OUT awi ETHERNET X II PES dici E DE L3 PER m Oo o mo E1 CHANNEL
Download Pdf Manuals
Related Search
Related Contents
Philips myGarden Pedestal/post 17809/93/16 Service Manual - ELECTRO LAGUNE Séance du 27 mai 2014 Le Conseil communautaire, légalement Dokument_1. IA-400 - Micromega Mod. 1092 - DOMUSWIRE Manuel d`installation SBC DUO 10 SBC DUO 20 Description des Manual Mini Scorpio Head Controles Video Pole Camera - Research Electronics International Copyright © All rights reserved.