Home
Flush 1 relay - User manual
Contents
1. seconds reporting enabled Power report is send with time interval set by entered value Technical Specifications Power supply 110 230 VAC 10 50 60Hz 24 30VDC Rated load current of AC output resistive load 1 X 10A 230VAC Rated load current of DC output resistive load 1 X 10A 30VDC Output circuit power of AC output resistive load 2300W 230VAC Output circuit power of DC output resistive load 240W 24VDC Power measurement accuracy P 5 50W 3W P gt 50W 3 Digital temperature sensor range sensor must be ordered separately 50 125 C Operation temperature 10 40 C Distance up to 30 m indoors depending on building materials Dimensions W x H x D 41 8 x 36 8 x 15 4mm Weight 28 Electricity consumption 0 4W For installation in boxes gt 60mm or 2M Switching Relay In case of load other than resistive pay attention to the value of cos and if necessary apply load lower than the rated load Max current for cos o 0 4 is 3A at 250VAC 3A at 24VDC L R 7ms UKA Z Wave Device Class BASIC_TYPE_ROUTING_SLAVE GENERIC_TYPE_SWITCH_BINARY SPECIFIC_TYPE_POWER_SWITCH_BINARY Z Wave Supported Command Classes COMMAND_CLASS_BASIC COMMAND_CLASS_SWITCH_BINARY COMMAND_CLASS_SWITCH_ALL COMMAND_CLASS_METER_V3 COMMAND_CLASS_SENSOR_MULTILEVEL_V3 COMMAND_CLASS_MULTI_CHANNEL_V2 COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_ MANUFACTURER_ SPECIFIC C
2. Flush 1 relay User manual Ordering codes e ZMNHAA2 Frequency range 868 4 MHz CEPT EU China Singapure South Africa UAE e ZMNHAAS Frequency range 921 4 MHz Australia Brazil New Zaeland e ZMNHAA4 Frequency range 908 4 MHz Chile Mexico USA Canada e ZMNHAAS Frequency range 869 0 Mhz Russia e ZMNHAAG Frequency range 916 0 Mhz Israel This Z Wave module is used for switching on or off the electrical device e g light fan etc The module can be controlled either through Z wave network or through the wall switch The module is designed to be mounted inside a flush mounting box hidden behind a traditional wall switch Module measures power consumption of electrical device and supports connection of digital temperature sensor It is designed to act as repeater in order to improve range and stability of Z wave network Supported switches Module supports mono stable switches push button and bi stable switches The module is factory set to operate with bi stable switches Installation e Before the installation disconnect power supply e Connect the module according to electrical diagram e Locate the antenna far from metal elements as far as possible e Do not shorten the antenna Danger of electrocution e Module installation requires a great degree of skill and may be performed only by a qualified and licensed electrician e Even when the module is turned off voltage may
3. OMMAND_CLASS_VERSION COMMAND_CLASS_MARK COMMAND_CLASS_BASIC Endpoint 1 12 Device Class GENERIC_TYPE_ SENSOR _ BINARY SPECIFIC_TYPE_ NOT_USED Command Classes COMMAND _ CLASS SENSOR BINARY COMMAND _CLASS_BASIC Endpoint 2 13 Device Class GENERIC_TYPE_ SENSOR _ BINARY SPECIFIC_TYPE_ NOT_USED Command Classes COMMAND CLASS _ SENSOR BINARY COMMAND _CLASS_BASIC This product can be included and operated in any Z Wave network with other Z Wave certified devices from any other manufacturers All constantly powered nodes in the same network will act as repeaters regardless of the vendor in order to increase reliability of the network Important disclaimer Z Wave wireless communication is inherently not always 100 reliable and as such this product should not be used in situations in which life and or valuables are solely dependent on its function UKA Warning Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new once the retailer is legally obligated to take back your old appliance for disposal at least for free of charge This user manual is subject to chan
4. ation parameters data type is 2 Byte DEC e Default value 0 e 0 Auto OFF disabled e 1 65535 0 01second 655 35 seconds Auto OFF enabled with define time step is 10mseconds Parameter no 30 Saving the state of the relay after a power failure Available configuration parameters data type is 1 Byte DEC e default value 0 e 0 Flush Irelay module saves its state before power failure it returns to the last position saved before a power failure e Flush Irelay module does not save the state after a power failure it returns to off position UKA Parameter no 40 Power reporting in Watts on power change Set value means percentage set value from 0 100 0 100 Available configuration parameters data type is 1 Byte DEC e default value 3 e 0 Reporting Disabled e 1 100 1 100 Reporting enabled Power report is send push only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts step is 1 NOTE if power changed is less than 1W the report is not send pushed independent of percentage set Parameter no 42 Power reporting in Watts by time interval Set value means time interval 0 65535 in seconds when power report is send Available configuration parameters data type is 2 Byte DEC e default value 300 power report in Watts is send each 300s e 0 Reporting Disabled e 1 65535 Isecond 65535
5. be present on its terminals Any works on configuration changes related to connection mode or load must be always performed by disconnected power supply disable the fuse Note Do not connect the module to loads exceeding recommended values Connect the module only in accordance to the below diagrams Improper connections may be dangerous Package contents e Flush 1 relay UKA Electrical diagram 230VAC L Qi L N a a n 4 B Notes for the diagram N Neutral lead L Live lead Q Output for electrical device 13 Input for switch push button or sensor 12 Input for switch push button or sensor I1 Input for switch push button TS Terminal for digital temperature sensor only for Flush 1 relay module compatible digital temperature sensor which must be ordered separately Electrical diagram 24VDC Notes for the diagram N 24VDC L 24VDC Q Output for electrical device 13 Input for switch push button or sensor 12 Input for switch push button or sensor I1 Input for switch push button TS Terminal for digital temperature sensor only for Flush 1 relay module compatible digital temperature sensor which must be ordered separately UKA S Service button used to add or remove module from the Z Wave network Durability of the module depends on applied load For resistive load light bulbs etc and 10A current consumption of each individual electrical device the durabili
6. ge and improvement without notice Qubino Goap d o o Nova Gorica Ulica Klementa Juga 007 5250 Solkan Slovenia E mail info qubino com Tel 386 5 335 95 00 Web www qubino com Date 08 12 2014 Document Qubino_Flush 1 relay user manual_V6 3_eng UKA
7. nodes Group 2 basic on off triggered at change of the input I2 state and reflecting its state up to 16 nodes Group 3 basic on off triggered at change of the input I3 state and reflecting its state up to 16 nodes Group 4 default reporting group reserved for the main controller UKA Configuration parameters Parameter no 1 Input 1 switch type Available configuration parameters data type is 1 Byte DEC e default value 1 e 0 mono stable switch type push button e bi stable switch type Parameter no 2 Input 2 contact type Available configuration parameters data type is 1 Byte DEC e default value 0 e 0 NO normally open input type e 1 NC normally close input type Parameter no 3 Input 3 contact type Available configuration parameters data type is 1 Byte DEC e default value 0 e 0 NO normally open input type e 1 NC normally close input type Parameter no 10 Activate deactivate functions ALL ON ALL OFF Available configuration parameters data type is 1 Byte DEC e default value 255 e 255 ALL ON active ALL OFF active e 0 ALL ON is not active ALL OFF is not active e 1 ALL ON is not active ALL OFF active e 2 ALL ON active ALL OFF is not active Flush 1 relay module responds to commands ALL ON ALL OFF that may be sent by the main controller or by other controller belonging to the system Parameter no 11 Automatic turning off relay after set time Available configur
8. ty exceeds 100 000 switches of each individual electrical device Module Inclusion Adding to Z wave network e Connect module to power supply with temperature sensor connected if purchased e bring module within maximum 1 meter 3 feet of the main controller e enable add remove mode on main controller e auto inclusion 30 minutes after connected to power supply or e press service button S for more than 2 second or e press push button I1 three times within 3s 3 times change switch state within 3 seconds Module Exclusion Reset Removing from Z Wave network e Connect module to power supply e bring module within maximum 1 meter 3 feet of the main controller e enable add remove mode on main controller e press service button S for more than 6 second or e press push button I1 five times within 3s 5 times change switch state within 3 seconds in the first 60 seconds after the module is connected to the power supply By this function all parameters of the module are set to default values and own ID is deleted If service button S is pressed more than 2 and less than 6 second module is excluded but configuration parameters are not set to default values Association Association enables Flush 1 relay module to transfer commands inside Z Wave network directly without main controller to other Z Wave modules Associated Groups Group 1 basic on off triggered at change of the output Q state and reflecting its state up to 16