1. Prefix to add before phone numbers dialed in GSM mode Voice dialer support Emits signal between dial and connect e User phone numbers Two user phone numbers can be set to which the GSM Adapter sends SMS message with the text specified in SMS settings window when the Adapter receives from the alarm control panel a Contact ID event code that is also specified in the list in the row assigned to the relevant SMS text e SMS forward Nr forwarding incoming SMS messages It is possible to forward messages incoming to the Adapter s SIM card up to two owner or user phone numbers This makes the use of cheap non subscription cards safe If the incoming SMS has been successfully forwarded it will be deleted from the SIM card to make space for further incoming messages Attention Never enter here the phone number of the SIM card placed into the module because this would initiate an infinite loop of SMS sent to itself right after the first incoming SMS causing significant expense e Automatic dial number This function can be used in certain specific tasks e g emergency telephone calls The appropriately set module shall immediately initiate a call to the preset number through GSM network when the receiver is picked up e Setting a prefix number necessary to access external PSTN line in case of using a telephone subsystem If the module s PSTN line input is connected to a telephone subsystem where the dialing of a p
2. GSM Adapter Mini Installation and User Manual for module version 2 02 and higher Rev 1 2 01 06 2010 Application area e Connecting an alarm control panel to monitoring station with Contact ID communication through GSM network e Security reserve secondary signal for the already existing PSTN communicators e Wired telephone adapter for flats houses cottages e A simple emergency alarm for elderly sick people by picking up the receiver e Remote diagnostics of centres built to long distances Features e Analogue telephone line simulation to transfer Contact ID signals and voice e Handling of landline PSTN in case of its cessation altering to GSM line simulation e Generating SMS message from the Contact ID codes of monitoring station reports alarm arming disarming e Automatic dial of pre set telephone number as a result of picking up the receiver emergency call function e Bell 103 V 21 digital data communication The alarm control panel becomes programmable through GSM data call remote maintenance downloading event code etc Table of contents Main functions of the GSM Adapter cccccceccsccseeceeeeeeteeeeeeeeeeeeeeseeeeeeeeeeetseeeeeteeeaeeees 3 eb ACAMON Al TEALUTES sarono t EE 3 setting the parameters of the Adapte niri 3 251 Mod le State MONHONNO ceisir seed ababetien webs EE 4 21 1 COMmmuUnIGAUON detal Sa a a 5 2 2 Parameter settings iescecsescavecalngsiecaiuearatatnrawntak
3. from the GSM system to the alarm pane s TIP input G2 Simulated line output from the GSM system to the alarm panel s RING input T1 Landline PSTN input T2 Landline PSTN input IN Direct GSM to activate connect to V S3 Reserved S2 Reserved S5 Reserved Attention If the metal housing of the alarm control panel on which the antenna is mounted is connected to the protective ground then it is necessary to connect the protective ground to the GSM Adapter module s V terminal as well 3 5 Function of the IN DIRECT GSM input Short circuiting the IN input to V terminal the module switches over to GSM transmission i e irrespective of the existence of an analogue phone line the Adapter initiates the call through the GSM network Apart from this it blocks and rejects incoming calls to the Adapter This ensures the call transmission in case there is some fault in the telephone system or subsystem i e if the PSTN line seemingly works but the alarm system cannot connect to the monitoring station through the PSTN network Most alarm systems can be programmed activate a PGM output after a certain number of unsuccessful dialing attempts If this PGM signal arrives to the IN1 input of the Adapter i e the PSTN cannot be used the unit will initiate the next call through the GSM network 4 Setting the alarm control panel Check the following settings on the alarms system e The reporting format must be set to CONTACT ID
4. or ADEMCO Express e The phone numbers of the monitoring station must be specified containing the area codes as well so that they can be called from the SIM card through the GSM network e Set the dialing to TONE mode 4 1 Further notes e The Adapter does not know in advance the length of the phone number to be dialled therefore do not wait too long before entering the next digit because if you do so the module might suppose that the dialling has already finished The Adapter expects at least 7 digits and does not start dialling until they are entered It starts calling a number of 7 and 10 digits after a 5 second pause In case of 11 or more digits the Adapter starts dialling after a 2 second pause This does not cause problems for alarm control panels due to fast and automatic dial but needs attention on manual dialling e Telephone numbers shorter than 7 digits can be dialled by entering after the number 5 Installation guide Before installation verify the future environment of the Adapter e Check the GSM signal strength using your mobile phone It may happen that the signal strength is not sufficient in the desired installation place In this case you have possibility to change the planned installation place before mounting e Do not mount the unit in places where it can be affected by strong electromagnetic disturbances e g near electric motors etc e Do not mount the unit in wet places or places with high degree
5. Adapter In the left side of the window divided part the bidirectional communication is displayed while in the right side the module s internal processes are shown Clear windows module s operation only on display Save to file Stop Start effect on the module s operation Close closes the communication details window clears the content of all windows does not have effect on the saves the whole content of all windows to text file stops and starts the data flow being displayed does not have 2 2 Parameter settings In this menu saved settings can be loaded from files saved to files or loaded to or from the module or compared using the corresponding icon buttons For the basic operation of the unit no setting is necessary So GSM line simulation and handling of PSTN line are automatic However if it is requested in order to reach the additional functions of the adapter as detailed in the following sections it is required to set certain parameters e g the owner s phone number the number to be dialed to access the external PSTN line the texts of SMS messages etc 2 2 1 Setting phone numbers Liz i a T eo GSM Adapter Mini 340 v2 02 2009 08 12 ae gt Module state Parameter settings Phone numbers SMS settings Call Filter BELL 103 User 2 AhEhEnAREEe eRe SMS forward Nr1d joo0326301111111 SMS mwad Nra I Ti yy ety 7 Automatic dial number Dial prefix number used for main phone line
6. SMS message centre is set correctly on the SIM card that is SMS can be sent from the phone e Disable PIN code request on the SIM card so that it shall not prompt for a PIN code on turning the unit on e Delete the unnecessary SMS messages from the card The SIM card necessary for the operation of the unit can be purchased from any GSM service provider The Adapter is independent of GSM providers 3 2 LED signals Indicates that the module is powered up but not connected to the GSM network If it lasts longer than 30 seconds check the SIM card and the antenna connection RED is continuously lit GREEN blinks slowly and The module is connected to the GSM network is ready to impulsely communicate GREEN is continuously lit network Indicates that a call is in progress through the GSM Indicates that the download process of parameters was unsuccessful e g download was interrupted Download has to be repeated RED and GREEN blink alternately 3 3 Antenna connection The antenna must be fixed to the module s FME pin connector The antenna in the package provides good transmission under normal reception circumstances In case of occasionally occurring GSM signal strength problems or and wave interference fading use another type of antenna or find a more suitable place for the Adapter 3 4 Module wiring ae LELEL V Supply voltage 9 24V DC V Supply voltage negative polarity GND G1 Simulated line output
7. T GSM input is not activated short circuited It is also possible to filter incoming voice calls by phone number which means the Adapter will accept incoming voice calls only from the specified phone numbers In this case voice calls initiated from other phone numbers will be rejected Attention In case of using telephone number filtering do not specify the inland area changing prefix before the telephone number only the area code and the phone number The telephone uses international format 3630 while displaying telephone numbers The module compares the received telephone number with the filtered telephone number by starting to compare them from the last digits The module handles the two numbers as identical even if 36 is left out There is also a possibility to limit the duration of incoming calls between O and 25 minutes call If value O is entered the duration of incoming calls is unlimited 2 2 4 Remote programming with BELL 103 V 21 format BL GSM Adapter Mini v1 15 GSM Adapter Mini 340 v2 02 2009 08 12 Module state Parameter settings SMS settings Call Filter BELL 103 GSM data call receiving Accept any incoming data call as BELL 103 call Accept data calls from the following phone numbers only Phone numbers Do not use prefix Enable BELL 103 callback The GSM Adapter Mini uses GSM voice channel which has 13 kbit s bandwidth for calls and monitoring station signals However the original s
8. adansdatindaiadehaceyadahrcaesdakteakadeaadabsfakedaxecay 6 221 DEUN PNONE TN MM eS sen a E E 6 2 2 2 SMS settings sending SMS messages in case of alarms or other events 7 2 2 3 Call filter receiving calls through the GSM network s nannannannennnnnennnnnnnnnnn 9 2 2 4 Remote programming with BELL 103 V 21 format cc eecceece sees eeee es 10 External elements and functions of GSM Adapter Mini cccecceeeseeseeeeeeseeeeeeaees 11 Ie MCE Lo a O ET I EAE OTAS 11 2e LEDS AS aa E adres cos A A AAP E A AN eneeeeaen 11 29 PANTSKa CONNECCION rren A 11 IA NOEN IEN Gc ace cece a E E E E E 12 3 5 Function of the IN DIRECT GSM NDUl eccriene n 12 setting the alarm Control panel xcsicecscacnodencacsioncmonsecnivendegudnemdscndncndondiandegudremdsgedeaedsnedsandebas 13 Ao AP UNINC NOLE Sanoa nina N 13 HStalauom GUC scree ipu en nSP EPRE SEER R 13 FE MOUN ae E O E OO EE reeree ree 13 52 PULLING INO OPETI se evetccsicvateentdvatarekaualaeebinetqvetdusterstecelavebdestquotdustevetdealavobtieteles 14 MT CCMIMIGA CLANS aroen canaan sacutaamaasaaaeu pastes sacananuroun 14 6r MECHIGAal SD SCINC AMON serres AAA AE 14 6 2 Generated telephone line SPECIFICATION cc cceccecceeeceeeeeeseeteeeeeeeeeseeeeeeteeaeees 14 G3 GOMIENT OM ING DACKAGC acain TT 14 64 Themanalacturers CONTAC erroen en EOR ETLER 14 Example ire cere U1 8 en A ANAN 15 1 Main functions of the GSM Adapter T
9. age The update procedure requires internet connection It can be also set here if the program should search for updates automatically on each opening or this is performed manually by clicking on the search link Setting parameters through USB connection Start GSM Adapter_Remoter_vxxx exe software Power up the module Connect the module to the PC using the enclosed USB cable When connection is established a green tick icon appears in the upper right corner of the program window and module version is displayed in the program header After this downloading uploading and monitoring functions become available e When programming is finished disconnect the USB cable from the module 2 1 BL GSM Adapter Mini v1 15 r Module state monitoring E E EE x GSM Adapter Mini 340 v2 02 2009 08 12 as Module state Parameter settings PstWtine ft SM ine state No Line Open Normal state GSM signal strength 0 31 21 TEER RRRRRRRRR ER Module state messages Phone Hw ON 10 08 50 lt GSM Adapter Mini start gt 10 08 50 BOOT GSM TYPE S300 10 09 03 Connection restored Communication details gt gt gt Clear message window Search for program updates USS When connected the module s current state can be monitored in the Module state window The following information are displayed the availability of landline phone state of the input the GSM line state the GSM signal strength and the modu
10. ent codes maximum 10 it will send an assigned SMS message to one or two telephone numbers that has been set by the user The text of the message to be sent can be set by the user X a E PEE BE i GSM Adapter Mini 340 v2 02 2009 08 12 lt n Module state Parameter settings 1 oe Phone numbers SMS settings Call Filter BELL 103 Event Code SHS message texts Inea The character in the SM5 text will be replaced with evwentcode parition zone USS The event codes can be found in the alarm control panel s installers manual The event codes in the list must consist of 4 hexadecimal digits each where the first digit makes the difference between new event 1 and restoration event 3 When entering event codes in the list code groups can be specified as well with the use of X character within the codes This means it is indifferent what character is received from the alarm control panel in the place substituted with character but the rest of the code corresponds to the one in the list the relevant event will be transmitted Note the module does not perceive signals sent through the PSTN line Note in case of entering OAADEMCO Express event codes in the GSM_Adapter_Remoter_vxxx exe software double 0O shall be inserted before the code E g 31 in case of alarm you shall enter 0031 in the list e Sending SMS messages on event without being connected to a monitoring station If reporting to a monito
11. he main function of the GSM Adapter Mini is to interface to GSM network an alarm system that can report to security monitoring station through PSTN telephone line The GSM Adapter makes possible the installation of alarm systems in places where landline PSTN is not available but it is necessary to send report to security monitoring station By means of GSM transmission the adapter improves the reliability of alarm reporting in cases when the PSTN alarm transmission does not work or fails e g when the phone lines are tampered or the telephone service is suspended due to technical reasons 1 1 Additional features Receiving incoming telephone calls possibility of restricting incoming calls Setting installations to sub stationary networks Synchronizing PSTN and GSM telephone calls with different prefix numbers Forwarding information of GSM account balance of prepay SIM card Converting alarm codes into SMS messages Emergency call function Interfacing voice diallers Remote programming of alarm systems 2 Setting the parameters of the Adapter Setting the parameters of the module is possible via USB connection using the GSM_Adapter_Remoter_vxxx exe software The language of the program can be selected by clicking on the language icons in the bottom right corner of the program window If necessary the version of the programming software can be updated by clicking on the Search for program updates link on the Connection p
12. le state messages The module message window can be cleared by pressing Clear message window button PSTN Line if there is a PSTN phone line connected to the correspondent module terminals then it is displayed whether it is available or not IN1 shows the state of the IN contact input GSM line state displays the state of the GSM line whether it is in use or not GSM signal strength displays the current GSM signal strength on a 31 point graphical scale Module version the version of the connected module is displayed in the header of the program window The example in the picture above shows the following information GSM Adapter Mini module type v2 02 firmware version 2009 08 12 firmware issue date 12 08 2009 2 1 1 Communication details By pressing the Communication details button a new window appears where the tasks and processes running in the module can be traced Communication details Phone Hw ON 10 21 45 GSM Adapter Mini start 10 21 45 BOOT GSM TYFE S300 Operations performed by the Adapter Connection restored Summary of recognized Contact ID reports DTMF communication passing through the Adapter Clear window Save to file 050 22 1 OF AT CREG CREG 0 1 OK A4T4 C50 050 22 1 OF AT CREG CAEL Uk AT CAREG CREG 0 1 Ok AT CREG C REG 0 1 LE AT4 C50 050 22 1 Ok AT CAREG CREQG 0 1 OF Internal processes of the
13. of humidity 5 1 Mounting Suggested installation method the GSM Adapter should be placed into the same metal housing as the alarm control panel Drill a hole on the metal housing for the FME connector Choose the drill size appropriate for the FME base part Fix the FME base with the enclosed screw nuts into the housing Ensure that the FME base and the metal housing has galvanic connection In case of plastic housing or weak GSM signal strength it may be necessary to use another directed type of antenna Attention If the metal housing of the alarm control panel on which the antenna is mounted is connected to the protective ground then it is necessary to connect the protective ground to the GSM Adapter module s V terminal as well 5 2 Putting into operation Make sure the SIM card is placed into the module properly Enable the caller identification service on the SIM card at the GSM service provider a few types of SIM cards do not have this function enabled by default Make sure the antenna is fixed properly in the Adapter Make sure the wiring is done as earlier instructed The device can be powered up 9 24 VDC Make sure that power supply is sufficient at the load of both the alarm control panel and the Adapter The quiescent current of the Adapter is 200mA however it can reach up to 500mA during communication 6 Technical details 6 1 Technical specification Supply voltage 9 24 VDC Maximum current consumption 500mA O
14. ound source is 64 kbit s which has been composed to the mentioned value so as to be able to make use of radio channel capacity Due to this procedure it is impossible to transmit periodic and constant amplitude signals like the FSK modulation of Bell 103 coding in a secure way For this reason the panel s data communication goes through GSM data channel Naturally remote diagnostics operates with call back function too at the expense of the Adapter s SIM card If this function is necessary then enable Enable BELL 103 callback option It is also possible to filter incoming data calls by phone number which means the Adapter will accept incoming data calls only from the specified phone numbers In this case data calls initiated from other phone numbers will be rejected To be able to program remotely alarm control panels with connected GSM Adapters a GSM modem is necessary T E L L GT64 recommended on the caller side The SIM cards placed in the modem and Adapter must support both way send and receive data GSM data call service CSD 3 External elements and functions of GSM Adapter Mini 3 1 SIM card case The cover can be opened by pulling horizontally towards the LED display on its marked end Insert the SIM card here and replace the cover after doing the following preparations Before starting to setup the Adapter insert the SIM card into a mobile phone and perform the following settings e Make sure that the number of the
15. perating temperature 20 C 70 C Transmission frequency GSM 900 1800 MHz 850 1900 MHz GSM phone type Simcom SIM340 Dimensions 84x72x32 mm Net weight 200g Gross weight packed 300g 6 2 Generated telephone line specification Line voltage 48 V Line current 25 mA Line impedance 600 Ohm Ringing voltage 72V 25 Hz Dial tone 400 Hz 6 3 Content of the package GSM Adapter Mini terminal connector GSM 900 MHz 1800 MHz antenna User manual warranty card CD USB A B cable 6 4 The manufacturer s contact T E L L Software Hungaria Kft 4034 Debrecen Vagohid u 2 Hungary Tel 36 52 530 130 Fax 36 52 530 131 Web www tell hu 7 Example of application Demand e Connecting the alarm control panel to monitoring station e Information on balance to the owner about the prepay card Tel 36 30 123 4567 e SMS to the owner about burglar alarm Tel 36 30 123 4567 Phone numbers SM5 settings Call Filter BELL 103 User 1 QOSb301T2 3456 User SMS forward Nr 2 Automatic dial number Dial prefix number used for main phone line Prefix to add before phone numbers dialed in GSM mode C Voice dialer support Emits signal between dial and connect Phone numbers SM5 settings Call Filter BELL 103 Event Code SHS message texts 111 310 ALARM The character in the SMS text will be replaced with eventcode partition zone USS Start the GSM _ Adapter_Remoter_vxxx exe a
16. pplication main steps 1 Connect the module to the PC through USB When connection is established a green tick icon appears in the upper right corner of the program window and module version is displayed in the program header 2 Select Parameter settings menu 3 Set the demanded parameters on Phone numbers page gt User 1 0036301234567 SMS forward Nr 1 0036301234567 on SMS settings page gt event code 1130 SMS message ALARM 4 Press Write parameters to module button 5 Disconnect from USB 15
17. refix number e g 9 is necessary to access the external PSTN main line this number must be entered on the adapter So the module omits the prefix number e g 9 in case of telephone calls through GSM network however it naturally initiates the call starting with the prefix number e g 9 in case the call is directed through a PSTN line e Cases when the prefix number necessary to access GSM and PSTN is different Another prefix number can be set for the module to insert in front of the dialed number in all those cases when the call is directed through GSM network e g if the panel calls the PSTN local number without the area code a prefix can be assigned that is necessary to initiate calls through GSM network This function came to be important because of some special characteristics of foreign PSTN networks e Voice dialler support One main characteristic of speech diallers is that they start playing the message in a certain time if no ringtone can be heard in the line By setting this function you will hear a simulated tone signal until the real ringtone can be heard This way can be avoided that the speech dialler starts to play the message before the call is received 2 2 2 SMS settings sending SMS messages in case of alarms or other events The GSM Adapter continuously watches the calls initiated through the GSM network and notices the reports of CONTACT ID or ADEMCO Express formats If it observes any of the specified ev
18. ring station is not requested it is still possible to send SMS messages in case of some events To do this enter 123456789 instead of the telephone number of the monitoring station into the alarm control panel In case of alarm the alarm control panel will dial this number and the GSM Adapter module will not initiate a real phone call but will simulate the operation of the monitoring station gives out handshake signals and acknowledges CONTACT ID and ADEMCO Express event codes This way it is possible to send SMS messages from the received signals as described in the previous section 2 2 3 Call filter receiving calls through the GSM network Ba GSM Adapter Mini v1 15 JE j 7 aie mal Le z GSM Adapter Mini 340 v2 02 2009 08 12 i S hi Module state Parameter settings h a e B SMS settings Call Filter BELL 103 Filter incoming calls Accept any incoming call Accept calls from the following phone numbers only Ho prefix numbers required use area code and phone number only Incoming call time limitation 0 25 minutes 0 riot limited The GSM Adapter Mini is able to manage calls coming in through the GSM network and to ring up devices telephone alarm system connected to it With this it can receive incoming GSM calls in places where there is no PSTN line extension by means of a simple analogue telephone This function works only if there is no PSTN line connected to the module and the IN DIREC
Download Pdf Manuals
Related Search
Related Contents
ProWebRabbit 取扱説明書~操作編~ Ver.7.0 SMC (SMC6924MTNMM) Network Management Device Datamax Pro Plus 2 Bedienungsanleitung.CDR Mode d`emploi WAT 7355 LabelLogic® KDC-PSW9521 KDC-M9021 KDC-8021 Brodit 512383 holder Hontech HT-A01 flat panel wall mount bizhub 40P User Manual - Braden Business Systems, Inc Copyright © All rights reserved.