Home

USER MANUAL - Sensor Access

image

Contents

1. 1 TTL output DC5V 20mA Communication One RS 232 port 9600 Baud Rate N 8 1 Xon and Xoff Keypad 12 Numeric Keypad LED 3 LEDs red green and yellow Operating environment range 35 C to 65 C 10 to 90 Humidity Storage environment range 40 C to 70 C 10 to 90 Humidity Mounting Wall mounted and US or European gang box Weight 0 464lbs 210gm Dimensions 4 17 x 3 40 x 1 22 Color Dark pearl grey Material Polycarbonate Format 26 bit Wiegand Certification UL 294 indoor and outdoor compliance FCC Class A part 15 and CE SENSORPROX 100R PIN120 SINGLE DOOR CONTROLLER 5 5 FRONT PANEL DESCRIPTION SENSORPROX 100R PIN120 Main Unit 6 IDENTIFYING SUPPLIED PARTS Please unpack and check the contents of the box MainUnit Wall Mount O Ring Manual 1 EA 1 EA 5 EA 1 EA SENSORPROX 100R PIN120 SINGLE DOOR CONTROLLER 6 7 INSTALLATION OF THE PRODUCT 7 1 Tear off page 27 and use the provided template to drill two 6 32 holes and one 1 2 hole on the proper location of the wall to mount the Wall Mount bracket as shown below If the gang box is already installed on the wall then skip this step 7 2 Using 2 screws install wall mount to the wall CAUTIONS Before mounting the SENSORPROX 100R PIN120 unit to the Wall Mount bracket operational testing of the unit should be completed as the locking pins will lock the unit to the Wall Mount Removing the
2. If a normally closed Exit button is used then see section 12 67 to change the detection scheme from the defaulted setting 9 5 Door Contact Sensor Connection Connect Door Contact sensor COM wire to Door Contact Input Green wire Connect Door Contact sensor NO wire to Power GND wire If a normally closed Door Contact sensor is used then see section 12 69 to change the detection scheme from the defaulted setting 9 6 Auxiliary Input Device Connection Applied to AUX Input 1 2 3 Connect one wire of the Auxiliary Input Device to the AUX Input wire Input 1 Orange Input 2 Green White banded Input 3 Brown wire Connect the other wire of Auxiliary Input Device to Power GND wire If a normally closed input device is used then see section 12 61 63 amp 65 to change the detection schemes from the defaulted settings 9 7 Auto Dialer Connection Separate purchase required The Auto dialer function of this unit has not been evaluated by UL Connect the input wire of Auto Dialer to TTL output Orange White banded wire Connect wire of Auto Dialer to DC 12V be sure that the existing power supply has enough capacity to support this accessory or upgrade to a sufficient one Connect wire of Auto Dialer to Power GND wire Connect Telephone Line plug RJ 14 to Auto Dialer If an active High Auto Dialer is used then see section 12 71 to change the TTL output level from the defaulted setting SENSORP
3. Built in Proximity Reader with up to 10cm read range with IDC170 card 512 Users or Card IDs including the Configuration card 5 independent input ports 4 output ports including 2 Form C Relays to facilitate either Power Failed Safe or Secure mode of operation All I Os behaviors and associated Timers are user programmable either through the keypad or the application software Door Lock and Unlock functions Configurable for Normal Secure mode of operation Secure Mode requires using external sensor s and alarm siren Covert Duress sensing and responding activate a silent alarm through the external Auto Dialer Programmable On Off audio feedback turning off audio feedback for Silent mode of operation Programmable the maximum number of unsuccessful attempts allow before activating the Alarm when exhaustive break in method is employed RS 232 communication port for interfacing with the SENSORPROX 100R PIN120 application software 3 LEDs red green and yellow for system operation status Chime Bell function to operate an externally connected Doorbell 4 SPECIFICATION Memory Flash Non volatile 1 millions times read write Power DC 12V 200mA max Proximity reader Built in Proximity reader with up to 10cm read range with IDC170 card User capacity 512 Users including the Configuration card Input Output 5 Inputs max rating at DC12V 20mA 2 Relay outputs DC12V 24V 2A max 1 chime bell output DC5V 150mA max
4. 42 Close door unconditionally 43 Enable QUICK ACCESS MODE 44 Disable QUICK ACCESS MODE 51 Disable Melody sound turning off both the melody amp keypress audio feedback 52 Enable Melody sound 60 Change keypad lock out time when Try Out error detected 61 Set Aux Input 1 Detection from L to H 62 Set Aux Input 1 Detection from H to L 63 Set Aux Input 2 Detection from L to H 64 Set Aux Input 2 Detection from H to L 65 Set Aux Input 3 Detection from L to H 66 Set Aux Input 3 Detection from H to L 67 Set Exit Button Input Detection from L to H 68 Set Exit Button Input Detection from H to L 69 Set Door Contact sensor Input Detection from L to H 70 Set Door Contact sensor Input Detection from H to L 71 Activate TTL output to H 72 Activate TTL output to L 77 Enable Chime Bell Output 78 Disable Chime Bell Output 80 Set delay time to activate SECURE MODE 81 Set Door Open time out for Door Contact sensor 82 Set number of times of Try Out 83 Set input keypress time out time SENSORPROX 100R PIN120 SINGLE DOOR CONTROLLER 16 84 Set Tamper Alarm output port 88 Enable Tamper Alarm 89 Disable Tamper Alarm 99 Re Initialize and erase all setup data 12 11 Add User Access Cards RF CARD ONLY MODE Configuration Card Command Cards to be registered Configuration Card 12 12 Add
5. Configuration PIN 12 44 Disable QUICK ACCESS MODE Configuration Card Configuration PIN Defaulted setting Disable 12 51 Disable Melody Sound Configuration Card Configuration PIN 12 52 Enable Melody Sound Configuration Card Configuration PIN Defaulted setting Enable 12 60 Change Keypad Lock out Time When Try Out Error Detected mm 00 99 min Defaulted Keypad Lock out time 01 min Configuration Card Command Keypad Lock out time Configuration PIN SENSORPROX 100R PIN120 SINGLE DOOR CONTROLLER 21 12 61 Set AUX Input 1 Detection from L to H AUX 1 input is detected on the raising edge of AUX 1 input Configuration Card Configuration PIN 12 62 Set AUX Input 1 Detection from H to L AUX 1 input is detected on the falling edge of AUX 1 input Defaulted setting Configuration Card Configuration PIN 12 63 Set AUX 2 Input Detection from L to H AUX 2 input is detected on the raising edge of AUX 2 input Configuration Card Configuration PIN 12 64 Set AUX 2 Input Detection from H to L AUX 2 input is detected on the falling edge of AUX 2 input Defaulted setting Configuration Card Configuration PIN 12 65 Set AUX 3 Input Detection from L to H AUX 3 input is detected on the raising edge of AUX 3 input Configuration Card Configuration PIN 12 66 Set AUX 3 Input Detection from H to L AUX 3 input is detected on the falling edge of AUX 3 input
6. Defaulted setting Configuration Card Configuration PIN 12 67 Set Exit Button Input Detection from L to H Exit Button input is detected on the raising edge of Exit Button input Configuration Card Configuration PIN 12 68 Set Exit Button Input Detection from H to L Exit Button input is detected on the falling edge of Exit Button input Defaulted setting Configuration Card Configuration PIN 12 69 Set Door Contact Sensor Input Detection from L to H Door Contact input is detected on the raising edge of Door Contact input Configuration Card Configuration PIN SENSORPROX 100R PIN120 SINGLE DOOR CONTROLLER 22 12 70 Set Door Contact Sensor Input Detection from H to L Door Contact input is detected on the falling edge of Door Contact input Defaulted setting Configuration Card Configuration PIN 12 71 Activate TTL Output to H TTL output changes the state from logic 0 to logic 1 when it activates Configuration Card Configuration PIN 12 72 Activate TTL Output to L TTL output changes the state from logic 1 to logic 0 when it activates Defaulted setting Configuration Card Configuration PIN 12 77 Enable Chime Bell Output Configuration Card Configuration PIN Defaulted setting Enable 12 78 Disable Chime Bell Output Configuration Card Configuration PIN 12 80 Set Delay Time to Activate SECURE MODE mm 00 99 min Defaulted Delay time 00 min Config
7. User Access Cards RF CARD PIN MODE Configuration Card Command Cards to be registered Configuration Card 12 13 Add User Access PIN PIN ONLY MODE Configuration PIN Command PINs to be registered Configuration PIN 12 14 1 Delete User Access Cards RF CARD ONLY MODE amp RF CARD PIN MODE Configuration Card Command Cards to be deleted Configuration Card 12 14 2 Delete User Access PIN PIN ONLY MODE Configuration PIN Command PINs to be deleted Configuration PIN SENSORPROX 100R PIN120 SINGLE DOOR CONTROLLER 17 lt TABLE 1 gt SETTINGS FOR COMMAND Symbol Setting Values Examples Remarks Output Mode OM You must add value and Setting value for activating time Activate Mode Value Activate only in Secure Mode 00 Activate in Safe amp Secure Mode 50 Setting Value for activating Output Port Activate Output Port Value Activate only Door Relay 01 Activate only Alarm Relay 02 Activate only TTL Output 04 Activate Door Relay amp TTL 05 Activate Alarm Relay amp TTL 06 EX1 Activate Door Relay In Safe amp Secure Mode Safe amp Secure Mode 50 Door Relay 01 OM 51 EX2 Activate Alarm Relay amp TTL only in Secure mode Secure Mode 00 Alarm Relay amp TTL 06 OM 06 tt tt is the activating time value seconds from 01sec to 99sec tt value 00sec means no operation PW PW is the 2 dig
8. a registered Card or PIN is read the Door will open for 3 seconds along with the do mi sol do melody Registered Card or PIN 11 3 Exit Open the Door To request for exit from the inside an Exit Button can be used to open the door for the same duration as in 11 2 11 4 Action And Alarm Caused by Unregistered Card or PIN When an unregistered Card or PIN is read thus access is denied and the Alarm can be activated for 2 seconds along with sol do sol do melody Unregistered Card or PIN If you do not want to activate the Alarm in case of unregistered access attempt then you can change this setting as shown in section 12 SENSORPROX 100R PIN120 SINGLE DOOR CONTROLLER 14 11 5 Secure Mode The last person to exit can change the operation of the unit from Normal Mode to Secure Mode by entering the Secure Code of onto the keypad Change to Secure Mode The Secure Mode will revert back to the normal mode when a registered card or PIN is presented entered 11 6 DURESS Alarm In case of Duress enter the 2 digit Duress Password and the door will open as usual however the Duress Alarm TTL Output will activate an external Auto Dialer to notify the appropriate personnel See section 9 7 and 12 29 for more instructions on this feature 11 7 Chime Bell Operation The key can be used to activate an external Chime Bell for 5 seconds the defaulted value 12 SETTING CHANGES Configuration Card PIN is required to change ex
9. cabinet slots as they may touch voltage points or short out parts that could result in fire or electric shock Never spill liquid of any kind on the product 7 To reduce the risk of electric shock do not disassemble this product by yourself but take it to qualified service whenever service or repair is required Opening or removing the covers may expose you to dangerous voltages or other risks Also incorrect reassembly can cause electric shock when the unit is subsequently used 8 Unplug this product from the Direct Current DC power source and refer to qualified service personnel under these conditions a When the power supply cord or plug is damaged or frayed b If liquid has been spilled on the product c If the product does not operate normally after following the operating instructions in this manual Adjust only those controls that are covered by the operating instructions in this manual Improper adjustment of other controls that are not covered by this manual may damage the unit and will often require extensive work by a qualified technician to restore normal operation d If the product exhibits a distinct change in performance 2 GENERAL A properly configured SENSORPROX 100R PIN120 is an intelligent single door controller that combines the convenience of wireless entry with the security of an alarm system Also the SENSORPROX 100R PIN120 system will give you field proven reliability and cost effective solution anywhere access controls a
10. Cards 4 6 digit Personal Identification Number PIN for each User Access Card Configuration Card User Access Cards PINs Configuration Card again to end task 4 The first card read becomes the Configuration Card and the following RF Cards PINs are registered as User Access Cards with assigned PINs Once all User Access Cards and PINs have been registered present the Configuration Card again to complete the registration Please keep the Configuration Card in a secure location for future changes SENSORPROX 100R PIN120 SINGLE DOOR CONTROLLER 12 5 Now the Main Unit is entered into the normal operation mode with factory defaulted settings 10 3 Registration of PIN ONLY MODE 1 Apply 12VDC to the unit All 3 LEDs will be flashing along with a powered up melody do mi sol me do do mi sol do 2 Press from the keypad PIN ONLY MODE 3 Enter to register Configuration PIN then to register for each subsequent User Access PIN at a time and then enter the Configuration PIN to complete the registration Configuration PIN User Access PIN Configuration PIN again to complete the registration 4 The first 4 6 digit PIN becomes the Configuration PIN and the subsequent 4 6 digit PINs are registered as User Access PINs Once all User Access PINs have been registered enter the Configuration PIN again to complete the registration Please store the Configuration PIN for future changes 5 Now the Main Unit is e
11. ROX 100R PIN120 SINGLE DOOR CONTROLLER 10 9 8 Wiegand Input Connection From Another Compatible Wiegand Reader Separate purchase required Connect wire of Reader to DC 12V be sure that the existing power supply has enough capacity to support this accessory or upgrade to a sufficient one Connect wire of Reader to Power GND wire Connect Wiegand output DATA0 wire of the additional Reader to DATA0 Pink wire Connect Wiegand output DATA1 wire of the additional Reader to DATA1 Cyan wire 9 9 RS 232 Communication Port Connection 9 pin connector COM Port female is required to connect serial communication RS 232 between Main Unit and Personal Computer Connect RS 232 TX Grey wire of Main Unit to pin number 2 of 9 pin connector Connect RS 232 RX Blue wire of Main Unit to pin number 3 of 9 pin connector Connect RS 232 GND Yellow wire of Main Unit to pin number 5 of 9 pin connector Plug in 9 pin connector to COM1 or COM2 Port of Personal Computer Install and run SENSORPROX 100R PIN120 Application Software 9 10 Chime Bell Connection Separate purchase required Connect wire of Chime Bell unit to Bell Output Brown White wire of Main Unit Connect wire of Chime Bell unit to Power GND wire SENSORPROX 100R PIN120 SINGLE DOOR CONTROLLER 11 10 INITIAL SETUP The Flash memory of each shipped STAR 100R PIN120 contains a minimum set of defaulted values but it does not have any other pr
12. ROX 100R PIN120 SINGLE DOOR CONTROLLER 19 12 28 Change Alarm Time When Magnet Detected Refer to Table 1 for OM tt 00 99 sec Configuration Card Command Output Mode Door time Alarm Time TTL time Configuration PIN 12 29 Register 2 Digit Duress Alarm Password PW 00 99 Defaulted PW 00 Do not use Configuration Card Command Password Configuration PIN Note 00 is registered as defaulted Password 12 30 Change Alarm Time When Duress Alarm Detected tt 00 99 sec Defaulted TTL time 03 sec Configuration Card Command TTL time Configuration PIN 12 31 Test Door Open Time Set By Command 21 12 32 Test Alarm Time Set By Command 22 12 33 Test Alarm Time Set By Command 23 12 34 Test Alarm Time Set By Command 24 12 35 Test Alarm Time Set By Command 25 12 36 Test Alarm Time Set By Command 26 12 37 Test Alarm Time Set By Command 27 Outputs set by command will be tested Configuration Card Command Configuration PIN SENSORPROX 100R PIN120 SINGLE DOOR CONTROLLER 20 12 39 Change Chime Bell Activating Time tt 00 99 sec Defaulted Chime Bell time 05 sec Configuration Card Command Chime Bell time Configuration PIN 12 41 Open Door Unconditional Configuration Card Configuration PIN 12 42 Close Door Unconditional Configuration Card Configuration PIN 12 43 Enable QUICK ACCESS MODE When QUICK ACCESS MODE is enabled Door will open simply by press key Configuration Card
13. SENSORPROX 100R PIN120 SINGLE DOOR CONTROLLER 1 USER MANUAL SENSORPROX 100R PIN120 SINGLE DOOR CONTROLLER 2 TABLE OF CONTENTS 1 Important Safety Instructions 3 2 General 3 3 Features 4 4 Specification 4 5 Front Panel Description 5 6 Identifying Supplied Parts 5 7 Installation of the Product 6 8 Color Coded amp Wiring Table 7 9 System Wiring for Typical Application 8 10 Initial Setup 11 11 Operation 13 12 Setting Changes 14 13 FCC Registration Information 25 15 Template 26 SENSORPROX 100R PIN120 SINGLE DOOR CONTROLLER 3 1 IMPORTANT SAFETY INSTRUCTIONS When using your Single Door Controller basic safety precautions should always be followed to reduce the risk of fire electrical shock and injury to persons In addition the following should also be followed 1 Read and understand all instructions 2 Follow all warnings and instructions marked on the product 3 Do not use liquid cleaners or aerosol cleaners Use a damp cloth for cleaning If necessary use mild soap 4 Do not use this product near water such as bath tub wash bowl kitchen sink laundry tub in a wet basement or swimming pool 5 This product should be operated only from the type of power source indicated on the marking label If you are not sure of the type of power supplied to your installation site consult your dealer or local power company 6 Never push objects of any kind into this product or through the
14. aged to try to correct interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on another circuit 4 Consult the dealer or an experienced radio TV technician for help SENSORPROX 100R PIN120 SINGLE DOOR CONTROLLER 26 15 TEMPLATE
15. enabled to enter the ID numbers through keypads Configuration Card Configuration PIN 12 74 Disable Keypad Input To Enter ID Number Keypad input is disabled to enter the ID numbers through keypads Defaulted setting Configuration Card Configuration PIN SENSORPROX 100R PIN120 SINGLE DOOR CONTROLLER 25 13 FCC REGISTRATION INFORMATION FCC REQUIREMENTS PART 15 Caution Any changes or modifications in construction of this device which are not expressly approved by the manufacturer for compliance could void the user s authority to operate the equipment NOTE This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interface and 2 This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to this equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the radio or television off and on the user is encour
16. eprogrammed values or user s data in it therefore Initial Setup is required upon the first time the unit is powered up in order to operate the unit properly 10 1 Registration of RF Cards for RF CARD ONLY MODE 1 Apply 12VDC to the unit All 3 LEDs will be flashing along with a powered up melody do mi sol me do do mi sol do 2 Press from the keypad RF CARD ONLY MODE 3 Present RF Cards as follow to register Configuration Card and User Access Cards Configuration Card User Access Cards Configuration Card again to end task NOTE The user may choose to register the 8 digit card numbers via the keypad instead of presenting the cards to the unit this implies that the user must know the 8 digit representation of each card 4 The first card read becomes the Configuration Card and the following RF Cards are registered as User Access Cards Once all User Access Cards have been registered present the Configuration Card again to complete the registration Please keep the Configuration Card in a secure location for future changes 5 Now the Main Unit is entered into the normal operation mode with factory defaulted settings 10 2 Registration of RF Cards with PINs for RF CARD PIN MODE 1 Apply 12VDC to the unit All 3 LEDs will be flashing along with a powered up melody do mi sol me do do mi sol do 2 Press from the keypad RF CARD PIN MODE 3 Present RF Cards as follow to register Configuration Card and User Access
17. isting or defaulted setting values or to manage user s access First present the Configuration Card or enter the Configuration PIN and enter the 2 digit command code RF Only Mode or RF PIN Mode PIN Only Mode or Configuration Card Command Code Configuration PIN Command Code Summary Table of Commands Command Action Change setting values 11 Add User Access Cards RF CARD ONLY MODE 12 Add User Access Cards and PIN RF CARD PIN MODE 13 Add User Access PIN numbers PIN ONLY MODE 14 Delete User Access Cards or PIN 21 Change Door open time when User Access Card or PIN is granted 22 Change Alarm time when User Access Card or PIN is denied 23 Change Alarm time when Try Out error detected SENSORPROX 100R PIN120 SINGLE DOOR CONTROLLER 15 24 Change Alarm time when Door Contact error detected 25 Change Alarm time when Aux Input 1 detected 26 Change Alarm time when Aux Input 2 detected 27 Change Alarm time when Aux Input 3 detected 28 Change Alarm time when magnet detected 29 Register 2 digits Duress Alarm password 30 Change Alarm time when Duress Alarm detected 31 Test Door open time set by command 21 32 Test Alarm time set by command 22 33 Test Alarm time set by command 23 34 Test Alarm time set by command 24 35 Test Alarm time set by command 25 36 Test Alarm time set by command 26 37 Test Alarm time set by command 27 39 Change Chime Bell activating time 41 Open door unconditionally
18. its Password for Duress Alarm Do not use 77 for PW as it is used for Secure Mode mm mm is activating time value minutes from 01min to 99min mm value 00min means no operation SENSORPROX 100R PIN120 SINGLE DOOR CONTROLLER 18 12 21 Change Door Open Time When User Access Card or PIN Is Granted tt 00 99 sec Defaulted Door Open time 03 sec Configuration Card Command Door open time TTL time Configuration PIN 12 22 Change Alarm Time When User Access Card or PIN Is Denied Refer to Table 1 for OM tt 00 99 sec Defaulted Alarm time 02 sec Configuration Card Command Output Mode Door time Alarm Time TTL time Configuration PIN 12 23 Change Alarm Time When Try Out Error Detected Refer to Table 1 for OM tt 00 99 sec Defaulted Alarm time 10 sec Configuration Card Command Output Mode Door time Alarm Time TTL time Configuration PIN 12 24 Change Alarm Time When Door Contact Error Detected Refer to Table 1 for OM tt 00 99 sec Door Open Time out setting is required for activating refer to 12 81 Configuration Card Command Output Mode Door time Alarm Time TTL time Configuration PIN 12 25 Change Alarm Time When AUX Input 1 Detected 12 26 Change Alarm Time When AUX Input 2 Detected 12 27 Change Alarm Time When AUX Input 3 Detected Refer to Table 1 for OM tt 00 99 sec Configuration Card Command Output Mode Door time Alarm Time TTL time Configuration PIN SENSORP
19. nd high security are required Each standard unit can store up to 512 users or card Ids The task of assigning cards and managing a user s database is so simple user friendly and can be accomplished in many ways it could be as simple as presenting each card to the unit or as descriptive as a user s database with an easy to use Graphical User Interface The SENSORPROX 100R PIN120 can interface and operate with these accessories Request for EXIT button Door Contact sensor PIR sensor Fire sensor and other sensors via 5 independent input ports Also output ports which include 2 Relays and 2 TTL outputs can be used to control the operation of other accessories such as Electric Magnetic Door Lock Alarm Chime Bell and Auto Dialer Moreover the status or behaviors of these input and output accessories are configurable to provide the system administrator with complete customized control of the system Besides the above configurable I O interfaced behaviors many of the SENSORPROX 100R PIN120 internal behaviors are programmable as well The internal operating parameters include the number of incorrect access attempts before alarm condition is triggered tampering protection from mounting removal and timers Furthermore every event or transaction can be captured and time stamped by the SENSORPROX 100R PIN120 application software via the provided RS 232 wires SENSORPROX 100R PIN120 SINGLE DOOR CONTROLLER 4 3 FEATURES Single Door Controller
20. ntered into the normal operation mode with factory defaulted settings 10 4 Factory Defaulted Setting Values After the Initial Setup the Main Unit uses the factory defaulted setting values below to execute the normal operation mode You may want to change these factory setting values or modify your User Access list refer to section 12 for instructions on how to customize the operation of your unit 1 When User Access Card or PIN is granted Door RELAY activates for 3sec Green LED lights on for 3sec 2 When User Access Card or PIN is not recognized Alarm RELAY activates for 2sec Red LED lights on for 2sec 3 Duress Password 00 Duress Alarm to TTL output port for 03 sec 4 QUICK ACCESS MODE Disable 5 Chime Bell output Enable Chime Bell activation time 05 sec 6 Melody sound Enable 7 Keypad lock out time when Try Out error detected 01 min 8 Detect all inputs from H to L SENSORPROX 100R PIN120 SINGLE DOOR CONTROLLER 13 9 Activate TTL output to L 10 Delay time to activate SECURE MODE 00 min 11 Door Open time out for Door Contact sensor 00 sec 12 Number of times of Try out 05 times 13 Input keypress time out time 20 sec 14 Tamper Alarm Disable Tamper Alarm output port 02 Alarm Relay 11 OPERATION 11 1 Normal Operation Mode Safe Mode When the Main Unit operates in normal mode the yellow LED is flashing every second 11 2 Open the Door When
21. ower Connection Connect wire of DC 12V power to Red wire and Red White banded wire Connect Power GND wire of DC 12V to Black wire and Black White banded wire 9 2 Door Lock Connection 9 2 1 Connection of POWER FAIL SAFE Door Lock Connect Door RELAY NC Blue White banded wire to DC 12V be sure that the existing power supply has enough capacity to support this accessory or upgrade to a sufficient one Connect wire of Door Lock to Door RELAY COM Grey Red banded wire Connect wire of Door Lock to Power GND wire 9 2 2 Connection of POWER FAIL SECURE Door Lock Connect Door RELAY COM Grey Red banded wire to DC 12V be sure that the existing power supply has enough capacity to support this accessory or upgrade to a sufficient one Connect wire of Door Lock to Door RELAY NO White Red banded wire Connect wire of Door Lock to Power GND wire SENSORPROX 100R PIN120 SINGLE DOOR CONTROLLER 9 9 3 Alarm Device Connection Connect Alarm RELAY COM White wire to DC 12V be sure that the existing power supply has enough capacity to support this accessory or upgrade to a sufficient one Connect wire of Alarm Device to Alarm RELAY NO Purple wire Connect wire of Alarm Device to Power GND wire 9 4 Exit Button Connection Connect one of the wires of Exit Button to Exit Button Input Yellow Red banded wire Connect the other wire of Exit Button to Power GND wire
22. unit from the Wall Mount bracket after they have been installed together may cause damages to the bracket and render its effectiveness 7 3 Insert 5 O rings to the wall mount as indicated then route the cable of the main unit through the center hole and push the main unit to wall mount to lock the main unit and make sure that the main unit is locked with wall mount SENSORPROX 100R PIN120 SINGLE DOOR CONTROLLER 7 8 COLOR CODED amp WIRING TABLE I O PORT NAME SIGNAL NAME COLOR CODED POWER Main Power V 12V Red wire amp Red with White band Power Ground 0V Black wire amp Black with White band OUTPUT Door RELAY 2A COM Grey wire with Red band Door RELAY 2A NC Blue wire with White band Door RELAY 2A NO White wire with Red band Alarm RELAY 2A COM White wire Alarm RELAY 2A NC Purple wire with White band Alarm RELAY 2A NO Purple wire TTL Output TTL Orange wire with White band CHIME BELL Output BELL Brown wire with White band INPUT Exit Button EXIT Yellow wire with Red band Door Sensor CONTACT Green wire Aux Input 1 IN 1 Orange wire Aux Input 2 IN 2 Green wire with White band Aux Input 3 IN 3 Brown wire WIEGAND INPUT OUTPUT Wiegand Data 0 DATA0 Pink wire Wiegand Data 1 DATA1 Cyan wire RS232 INTERFACE RS232 TX TXD Grey wire RS232 RX RXD Blue wire RS232 GND GND Yellow wire SENSORPROX 100R PIN120 SINGLE DOOR CONTROLLER 8 9 SYSTEM WIRING FOR TYPICAL APPLICATION 9 1 P
23. uration Card Command Delay time Configuration PIN 12 81 Set Door Open Time out for Door Contact Sensor tt 00 99 sec Defaulted value 00 sec means no detect Door Contact Sensor refer to 12 24 for Alarm time settings Configuration Card Command Door Open time out Configuration PIN SENSORPROX 100R PIN120 SINGLE DOOR CONTROLLER 23 12 82 Set Number of Times of Try Out NN 00 99 times Defaulted Try out numbers 05 times Configuration Card Command Try out numbers Configuration PIN 12 83 Set Input Keypress Time out Time tt 10 99 sec Defaulted Keypress time out 20 sec Minimum tt 10 sec Configuration Card Command Keypress time out time Configuration PIN 12 84 Set Tamper Alarm Output Port Refer to Table 1 for OM Defaulted Output port 02 Alarm Relay Configuration Card Command Alarm Output Port Configuration PIN 12 88 Enable Tamper Alarm To comply with UL 294 the Standard for Access Control System Units the Tamper Alarm must be enabled Configuration Card Configuration PIN 12 89 Disable Tamper Alarm Configuration Card Configuration PIN Defaulted setting 12 99 Re Initialize and Erase All Setup Data Please use this command when you really want to erase all data and start the unit from the beginning Configuration Card Configuration PIN SENSORPROX 100R PIN120 SINGLE DOOR CONTROLLER 24 Additional Function 12 73 Enable Keypad Input To Enter ID Number Keypad input is

Download Pdf Manuals

image

Related Search

Related Contents

APart MA200R AV receiver  Mode d`emploi du préservatif masculin (lingala)  Appuyez sur le bouton  Manual, Slide & Remote Control Installation and User  取扱説明書 DYNASERV DR5H00,UR5HG3,UR5HP3  第5 不活性ガス消火設備(全域放出方式の二酸化炭素消火  

Copyright © All rights reserved.
Failed to retrieve file