Home
PD-LED2004 User manual-p1
Contents
1. Ensure that mains power is switched off during installation of the wiring Note tools required 4 0 Pencil Electric drill Hammer Screwdriver www energenie4u co uk ENERGEN iE amp Microwave Sensor Lamp ENER215 instruction your switch is my command e Step1 Unscrew the plastic cover to gain access to the adjustment controls Fig 1 e Step2 Turn the controls for the required settings Fig 2 S S Oi SENS TIME LUX Fig 2 Detection range setting sensitivity a Adjust the Reach control to set the radius of operation of the microwave detection zone D An ideal ceiling mount heght is 2 5m turn the Reach control fully anti clockwise to select the minimum reach approx 1metre and fully clockwise to select maximum reach approx al 10metres SENS NOTE The sensitivity assumes a person to be between between 1 6m 1 7m tall moving at a speed of 1 0 1 5m sec Adjust the sensitivity to suit the local conditions Avoid setting to the maximum value as it may react to curtain movement and small animals Also be aware of power grid and electrical equipment that may interfere with the correct operation of the sensor Lowering the sensitivity may improve the operation in situations where there may be electrical interference Time setting fully anticlockwise and a maximum of 12min turned fully clockwise Any movement detected before this time has elapsed will re start the timer
2. It is recommended to select the shortest time when adjusting the detection sensitivity O The light can be set to stay ON for any period of time between approx 6sec turned TIME www energenie4u co uk ENERGEN E amp Microwave Sensor Lamp ENER215 instruction your switch is my command NOTE There will be a delay of approximately 1 second after the light switches OFF before movement can be detected again Light level control nD The chosen light threshold can be set from approx 10 2000lux Turn Ss it fully anti clockwise to select dusk operation at about 10 lux Turn it fully clockwise to select daylight operation at about 2000lux Turn the control ee fully clockwise when adjusting the motion detector sensitivity LUX Note To avoid damaging the controls please do not attempt to adjust past the limit stops The range of adjustment is limited to 270 e Step 3 Ensure that there are no pipes or cables of any sort behind the panel where the light is to be located Hold the base to the ceiling and mark the locations of the fixing holes with a pointed instrument such as a screwdriver e Step 4 Drill holes at the locations marked previously and fit rawl plugs as necessary Before drilling please ensure there are no pipes or electrical wires in the way that can be accidentally damaged by drilling Wear suitable Fig 3 Fig 4 protective glasses and dust masks e Step 5 Feed the power cable
3. from the lighting circuit through the opening in the housing and connect to the terminal points ensuring correct polarity etc Pw EO Nec SA Fe CAD A soot 40mm 10mm Fig o Fig 6 www energenie4u co uk ENERGEN E amp Microwave Sensor Lamp ENER215 instruction your switch is my command e Step 6 Fix the base with the screws supplied Concrete ceiling Fig e Step 7 Attach the cover to the base with the screws supplied l ETA ELE A L A Fig 8 TROUBLESHOOTING o Fault Failure cause Solution Lux and or detection range set incorrectly Adjust settings Light does not come on The power is off Turn the power on Faulty unit unit Repair or replace Light always on Bit e is a continuous motion in the detection area Check for any disturbance Lamp not mounted securely Check mounting www energenie4u co uk ENERGENjE amp Microwave Sensor Lamp ENER215 instruction your switch is my command NOTE the high frequency output of this sensor is lt O0 2mW This is just one 5000 of the transmission power of a mobile phone or a microwave oven Detection of human movement NN Warning 1 Always remove ALL power when working on the unit 2 Ensure installation and adjustment is carried out by suitably qualified personnel 3 Improper installation or use may invalidate product warranty www energenie4u co uk ENERGENiE E
4. C diffuser resistant to fracture and j to ultraviolet light to limit discolouring i ses cccococoo oocoococoo oecsoeoo Lamp cover l fixing hole Threading hole SPECIFICATIONS Rating 220 240V AC Line frequency 50Hz HF system 5 8GHz CW ISM wave band Rated load 15W Max Transmission power lt 0 2mW Luminous flux 1000Im Time setting 6sec to 12min adjustable Detection angle 360 www energenie4u co uk a gt xf d SFS ARNG f gt ane J o Lamp cover fixing hole o Microwave sensor OE Lamp cover Lamp cover Y fixing hole fixing hole ee Lamp cover Knob fixing hole PC cover Detection range 1 10m radii adjustable Light control 10 2000LUX adjustable Standby power lt 0 9W Installation height 2 5m 3 5m ceiling mount Net weight 1 03 kg Lamp part LED quantity 96PCS LED T5050 LED lamps are 80 more efficient than incandescent bulbs and 50 more efficient than fluorescent bulbs ENERGEN jE amp Microwave Sensor Lamp ENER215 instruction your switch is my command OPERATING RANGE Installation height 2 5 3 5M Detection distance adjustment range Detection angle adjustment range SPECTROGRAM S00 4027 425 446 471 494 517 540 563 556 609 632 655 678 701 P24 747 r0 MT INSTALLATION 1 Please keep away from the children A N Warning 2 Please avoid fire high temperature damp places for installation 3
5. ENERGEN E your switch is my command Packing list in Quantity Ceiling Mount Lamp LEDS 96PCS 3 Sealing ring 4x12 Y type Stainless Screw p aL A m i T E 7 E Microwave Sensor Lamp ENER215 instruction 98 5mm PRODUCT INFORMATION Ideal for energy saving this a low power LED bulkhead lamp with built in microwave sensor control High level output with 96 high brightness LED lamps Rated load is 15 Watt which is equivalent to a 150 Watt incandecent light source The low power microwave radar detection uses only 0 2mW power which is harmless to humans It has a range from 1 to 10M and is immune to temperature humidity noise and pollution It is ideal for ceiling installation and is simple to install Suitable for halls corridors stairwells bathrooms and similar locations The sensor will detect human presence and switch the light on for a period which can be pre selected via the internal timing control from 6 seconds to 12 minutes It can also be adjusted to work for a range of up to 1 10 metres which can also be pre selected using the dedicated internal control There is a third internal adjustment that allows the unit to operate in variable lighting levels from 10 to 2000Lux night day The sensor will operate through glass plastic and wood and should be adjusted at installation to achieve the required sensitivity ditt gA Uses tough high quality P
6. Microwave Sensor Lamp ENER215 instruction your switch is my command FEATURE OVERVIEW Low Power LED bulkhead lamp wtih built in microwave motion sensing 50 energy savings compared with traditional fluorescent lamps Long Life 30000hrs 3 times longer than fluorescent lamps Instant start Not dimmable Negligible UV and IR radiation output High sensitivity microwave sensor that detects human movement and switches the light on and off automatically Built in day light sensor Adjustable time delay and sensor sensitivity www energenie4u co uR Energenie is a trading name of Sandal plc Claremont House Deans Court Bicester Oxon OX26 6BW www energenie4u co uk
Download Pdf Manuals
Related Search
Related Contents
- eQ-3 LG 42LM5800 42" Full HD 3D compatibility Black LED TV XYLOCAINE 2 % GEL (en seringue), gel urétral Copyright © All rights reserved.
Failed to retrieve file