1. DMX functions The RUSH Club Smoke Dual address setting must match the DMX address allocated to it on your controller To set the address see Setting the DMX base address on page 18 The RUSH Club Smoke Dual requires four DMX channels For example if the RUSH Club Smoke Dual is set to DMX address 100 channel 1 will be controlled by address 100 channel 2 will be controlled by address 101 channel 8 by address 102 and channel 4 by address 103 When the system is at running temperature and is under DMX control it displays TI MA v MA The functions of each DMX control channel are shown on the following page DMX control 23 Channel 1 Fog haze output 1 level Channel 2 Fog haze output 2 level Channel 3 Fog haze output 3 level Channel 4 Special functions 24 DMX value Function Macro description range 0 12 Idle range None 13 240 Output 0 100 241 255 Output 100 DMX value Function Macro description range 0 12 Idle range None 13 240 Output 0 100 241 255 Output 100 DMX value Function Macro description range 0 12 Idle range None 13 240 Output 0 100 241 255 Output 100 DMX value Function Macro description range 0 50 Idle range None 51 100 Prime base 5 seconds within station range to activate once 101 150 Not used 151 200 Heater off amp 5 seconds within shutdown range to activate once 201 255 Heater on None but heaters norma
2. Isolate the system from power and allow to cool completely before cleaning The fog haze output nozzles remain hot for a period after use e Remove dust from the air vents with a soft bRUSH cotton swab vacuum or compressed air e Clean fog fluid residues from the fog output of the system using a damp cloth e Clean the outer casing with a damp cloth only Fuse replacement The fuses for the system are located on the electronics board inside the units DANGER Disconnect the power supply before removing any covers Live parts inside To replace a fuse disconnect the power cord from the supply unscrew the screws holding the top cover of the unit and remove the cover The electronics board is located in the compartment under the display Remove the spent fuse and replace with one of exactly the same size and rating The fuse type is indicated below Contact Martin Service if the fuse blows repeatedly Fog head 120 V 10AT 230 V 6 3 AT Haze head 120 V 10AT 230 V 6 3 AT Pump unit 120 V 3 15 AT 230 V 3 15 AT Basic service Troubleshooting Problem System will not produce fog haze when control panel set to RUN or remote control Fog Haze switch turned on System can be fired from control panel or remote control but not by DMX controller Probable cause s System not at operating temperature Suggested remedy Wait until HE HT message no longer shown En E or HHZ E setto 0 Increase
3. aa 1150W 5 1A Fog head US modell 1000 W 8 6A Haze head EU model ii etd 900 W 4 0A Haze head US modell 900 W 7 6A Base pump unit EU model AA 180 W 0 9 A Base pump unit US model 180 W 1 7 A Measurements made at nominal voltage Allow for a deviation of 10 Thermal Maximum ambient temperature Ta max 40 C 104 F Exterior surface temperature steady state at 20 C ambient 30 C 86 F Max nozzle temperature 000000a aaa anna nennen nnne nnne nnne 290 C 554 F Approvals EU e EN 61000 6 3 2007 LE EE EN 60335 1 2002 A15 2011 Immunity itii en Fee RR Ce iR REDE Free X rer rere rer EN 61000 6 1 2007 met a ed sin Ue EN 62233 2008 Electromagnetic fields US safety pending itte ee dd enh aie UL998 Canadian safety pending essen CSA C22 2 No 104 Included items Fog head Fast in T connector Patch lead CAT 5E 10 m 32 8 ft Fluid line 10 m 32 8 ft Haze head Fast in T connector Patch lead CAT 5E 10 m 32 8 ft Fluid line 10 m 32 8 ft Pump unit Fluid container 10 I 2 64 US gal Power cable 1 5 m 4 9f t IEC to stripped ends 230 V Power cable 1 5 m 4 9 ft IEC to NEMA 5 15P plug 115 V Specifications Accessories Multifunction Digital Remote Control RUSH Club Smoke Dual DIN 92765043 External fluid kit option P N 92620030 Ordering information Pump unit RUSH Club Smoke Dual US model 120V PIN 92250140 Pump unit
4. change the option to Press the Enter button to start the priming function The pump unit will pump at full power for a short time to purge air from the pipes inside the unit To exit this menu if you decide not to activate the Prime function select N and press Enter Priming system with Quick access buttons The four quick access buttons below the display are used for priming the system output rate The three left hand buttons will prime the outputs to heads 1 2 and 3 independently This is used to expel air from the pipes between the pump unit and the heads after installation Priming continues while the buttons are held down and stops when the buttons are released The heads must be in Ready state for the output prime function to operate Keep the button held down until fog haze is produced from the head The right hand button runs a timed sequence to prime the base unit and is normally used when replacing fluid This will also reset the Fluid Out error The heads do not need to be in Ready state for the base prime function to work and no fog haze will be produced Resetting options to factory settings The factory settings configure a standard mode of operation for the system Use the Previous Next buttons to select the H 5 E T option Use the Up Down buttons to change the option to Press the Enter button to reset all options To exit this menu if you decide not to reset the options select N and press
5. in an OFF period the puki number counts down to show the off time FLU ERR Run out of fluid Refill the fluid tank and operate the base Gelee prime function bottom right hand button on control display CRL ERR The system has detected an error with its calibration settings poring Dany and will not operate Call Martin Service TEMP FAR The system has detected an error in the temperature sensor STI 7 and will not operate Call Martin Service Resetting the system after fluid out If the system runs out of fluid simply refill the fluid container and follow the priming instructions on page 18 28 Status messages Specifications Physical Fog head La th a PE ed ida 356 mm l or 259 mm Height mt 169mm 278mm including hanging bracket Diy Weight EE 7 6 kg Haze head ESA e ida kn SES niu Aoi eit 395 mm Wii ama td 259 mm Height nies 209mm 318mm including hanging bracket ID AVI E 8 9 kg Pump unit Depth die eii eee rit ne 257 mm WI ge AA AA 415 mm Height MC 431 mm Dry Weight 2 13 4 kg Performance Operating time ieget tete ote continuous Warm up time approx esses seien anna ennemis 7 minutes Haze maximum operating time at maximum output with 10L fluid 15 9 hours Fog maximum operating time at maximum output with 10L fluid 2 8 hours Control and programming Control options onboard control panel DMX optional digital remo
6. setting 1 HUN setto 0 Increase setting DMX signal present Disconnect or turn off DMX controller DMX address setting Change DMX address page incorrect 18 Poor connection in DMX line Check DMX cables and connections LINK menu is set to SEND Set LINK menu to RECV All fog haze outputs are weak Fog haze output is weak on one particular head Base pump unit requires priming Channel requires priming Prime base pump unit page 18 Prime the channel page 18 Wet greasy non uniform fog output fluid drips or spits from nozzle or very loud noise when firing system Incompatible fog fluid Use approved fluid System appears dead Mains fuse blown Replace fuse page 26 No power at AC cable inlet Check power cable and circuit breaker System causes DMX errors to occur on other units when connected to a DMX system LINK menu is set to SEND Set LINK menu to RECV Troubleshooting 27 Status messages message reason UF The heaters are Off the unit is shut down HEAT The unit is heating up to operating temperature RIY The heater is at operating temperature but Fog is not turned on RUN set to STBY or FOG set to 0 RE The heater is at operating temperature and the unit is under CE DMX control ra The system is in Timer mode and is in a RUN period the Ke moto number counts down to show the run time BETE The system is in Timer mode and is
7. the furthest fog head It must be the lowest point of the system and not more than 10m below the highest head Keep 150mm clearance around the unit and 300mm above the unit Before using the system ensure that a grounding type earthed power plug that fits the local power outlets is installed on the IEC cable provided and on the mains cable of each head DANGER Make sure the power plug is correctly rated For EU 230 V use fit a plug rated 6 amps minimum For US 120 V use fit a plug rated 10 amps minimum When installing the plug follow the plug manufacturer s instructions and connect pins as follows Yellow and green wire to ground earth blue wire to neutral and brown wire to live The table below shows some common pin identification schemes wire function marking screw colour brown live L yellow or brass blue neutral N silver greenlyellow earth e green Installation and setting up 13 14 Before connecting the system to power verify that the AC supply is adequately dimensioned for the current draw of the system Base unit 0 9 A 230 V EU model 1 7 AQ 120 V US model Fog Heads 5 1 A 230 V EU model 8 6 A Q 120 V US model Haze Heads 4 0 A 230 V EU model 7 6 A O 120 V US model Check that the local AC voltage is appropriate as indicated on the system s serial number label If your AC voltage is outside the appropriate range do not use the system Contact Martin Ser
8. D AND SAVE THESE INSTRUCTIONS RUSH CLUB SMOKE DUAL user manual Dimensions All dimensions are in millimeters Haze Head 259 395 318 WWW Sw w w Su Sur Su Su S I 209 Fog Head 259 356 278 EZ WAY 2 Dimensions Pump Unit 415 257 aa 431 2013 2015 Martin Professional ApS Information subject to change without notice Martin Professional and all affiliated companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual The Martin logo the RUSH by Martin logo the RUSH by Martin name the Martin name and all other trademarks in this document pertaining to services or products by Martin Professional or its affiliates and subsidiaries are trademarks owned or licensed by Martin Professional or its affiliates or subsidiaries Martin Professional Olof Palmes All 18 8200 Aarhus N Denmark www martin com Dimensions 3 Contents DIMENSION m 2 Contents x eme ee es Atte oi tte eade sudo tte ie oes s ee PJ 4 Safety information mener renerne renerne tn naeh nhanh kaaa sein nass tasse reen nen nn er 5 Product OVervieW d anu m Cap mda impia 8 ProductYescripliOr is ene ec etta e te te
9. Enter Control settings 19 20 The factory settings are option setting FOG UL HAZE UA TRUN D seconds TOFF ru seconds RUNF OFF RUNH OFF ADDR WE I DISP NORM LINK RELY PRME N Control settings Remote control Overview The digital remote control available separately may be used for remote control of the RUSH Club Smoke Dual Several systems may be controlled from one remote using the LINK function see page 18 XLR socket Display XLR socket on rear Haze button Fog button Functions The remote control provides the following functions e Fog button turns fog head output on and off Press once to start output from fog heads and again to stop e Haze button turns haze head output on and off Press once to start output from haze heads and again to stop e Fog level setting FOG 0 10096 e Haze level setting HAZE 0 100 e Timer run time off time settings TRUN 0 99 seconds TOFF 0 99 seconds e Hunt run mode for fog heads RUN OFF STBY TIME CONT e RunH run mode for haze heads RUN STBY TIME CONT The functions are the same as on the built in control panel and are described on page 13 The RUN menu duplicates the functions of the Fog and Timer buttons The buttons are simply a quick way to control this menu function Connection The remote control has two identical XLR connectors on the top and back for connection to the RU
10. MX system ensure the LINK menu is set to RECV the default setting to avoid causing DMX errors to other devices on the system Setting the master slave link mode It is possible to control several systems from one digital remote The system with the remote plugged into it becomes the Master The other systems are Slaves The systems are interconnected with DMX cabling Use the Previous Next buttons to select the L I NK option Use the Up Down buttons to select REL v slave unit or 5 E N Ii master unit Press the Enter button to store the link setting The system should be set to E N H only if it is running as a master If running as a slave stand alone or DMX controlled it should be set to EL Y Ifa system set to ENI is connected to an active DMX system the DMX will be corrupted causing flickering of lights and other strange symptoms Priming the system after fluid out If the system runs out of fluid it will automatically shut down and show FLL HLT onthe display to prevent damage to the pump To suck the new fluid back into the system and reset the FLU OUT error replace refill the fluid tank and use the prime function Control settings e To prime the pipework in between the pump units and the heads after installation use the 4 quick access buttons below the display to prime outputs 1 2 3 or the base independently See next section Use the Previous Next buttons to select the F HF M E option Use the Up Down buttons to
11. RUSH Club Smoke Dual EU model 230V DIN 92250130 Fog head RUSH Club Smoke Dual US model 120V P N 92250160 Fog head RUSH Club Smoke Dual EU model 230V P N 92250150 Haze head RUSH Club Smoke Dual US model 120V DIN 92250180 Haze head RUSH Club Smoke Dual EU model 230V DIN 92250170 Specifications subject to change without notice For the latest product specifications see www martin com uU Disposing of this product F Martin products are supplied in compliance with Directive 2002 96 EC of the European Parliament and of the Council of the European Union on WEEE Waste Electrical and Electronic Equipment as amended by Directive 2003 108 EC where applicable Help preserve the environment Ensure that this product is recycled at the end of its life Emmi Your supplier can give details of local arrangements for the disposal of Martin products Specifications 31 et Jan www martin com e Olof Palmes All 18 8200 Aarhus N e Denmark Tel 45 8740 0000 Fax 45 8740 0010
12. SH Club Smoke Dual system The back connector allows the remote to be mounted into a panel or console Plug the cable provided with the remote control into either of these sockets and into the 3 pin XLR plug nearest the mains switch on the top panel of the base pump unit not the 3 pin DMX plug Remote control 21 22 The remote control is powered through its cable by the RUSH Club Smoke Dual no batteries are required The cable may be extended to up to 25 m 82 ft with a 3 pin XLR DMX cable available from your Martin dealer Remote control DMX control Overview DMX is a digital control system widely used in entertainment and architectural lighting Any controller meeting the DMX 512 standard may be used to control and program the fog output of the RUSH Club Smoke Dual When a DMX signal is present the RUSH Club Smoke Dual stand alone functions do not work To fire the unit from the control panel or remote control the DMX controller must be powered off or disconnected Connection The RUSH Club Smoke Dual system provides 3 pin and 5 pin XLR connectors on the top of the base pump unit for DMX connection You can use either the 3 pin or 5 pin connectors for in or link through but you should not use the unit as a splitter by connecting both the 3 pin and 5 pin outputs For best results use cable designed for high speed digital data transmission Suitable DMX cable is available from your Martin dealer
13. afely and servicing instructions in the remainder of this manual Locate the head s in a suitably large area with nothing in front of the fog output Connect the fluid pipes from the head units to the base unit A maximum of 2 heads of the same type fog or haze can be connected to each output on the base unit If you are connecting 2 heads use a T connector to link the pipes Connect the heads to the base unit with RJ45 cables If you are connecting 2 heads to an output the second head is linked from the first Fill the fluid tank in the base unit with RUSH Club Smoke Dual Fluid only Use of other fluid will void the warranty Connect a suitably rated power supply to the heads and to the base unit using the supplied IEC cable The power requirements are Base unit 0 9 A 230 V EU model 1 7 AQ 120 V US model Fog Heads 5 1 A 230 V EU model 8 6 A Q 120 V US model Haze Heads 4 0 A 230 V EU model 7 6 A O 120 V US model Now set the mains switches on the rear of each head and on the top of the base unit to the ON position The display will show HEAT If the display shows OFF use the menu panel to set the RUNF option to CONT After about 6 8 minutes the display should show CONT and the system will begin producing fog If the display shows RDY use the menu panel to set the RUNF option to CONT to start fog Once the system has heated the first time you will need to prime the pipework using the 4 prime buttons
14. at the bottom of the control panel Making fog and haze If you want to adjust the fog density manually press the Menu lt gt buttons until the display shows FOG then press the Enter button and use the Value up down buttons to select a value above 0 The Haze density can be adjusted using the HAZE menu the same way You can also adjust the fan speed using the FAN menu If no fog is produced it may be necessary to prime the system press the Menu lt gt buttons until the display shows PRME then press the Value Up button so the display shows Y then press the Enter button Quick Start Installation and setting up DANGER DO NOT operate the system until you have read and observed all the precautions listed under Safety information on page 5 The RUSH Club Smoke Dual heads are designed to be located on the floor or may be suspended using the fitted flying bracket The heads can operate in any orientation from vertically down to vertically up They must not be used upside down If the heads are to be suspended ensure the mounting surface can support the weight of the head Do not suspend the heads over areas where people will be underneath Use only the fitted flying bracket to suspend the head Ensure that there is at least 100mm clearance all round the head and at least 60cm in front of the fog output The base pump unit can be located in any convenient location but must be within 10m of the furthest haze head or 50m of
15. e indicated on the system s serial label matches your local AC power voltage If your AC power voltage does not match do not use the system Contact Martin Service for assistance Before using the system check that all power distribution equipment and cables are in perfect condition and rated for the current requirements of all connected devices If the system or any cables connected to it are in any way damaged defective wet or show signs of overheating stop using the system and contact Martin Service for assistance If the supply cord is damaged it must be replaced by a special cord or assembly available from the manufacturer or its service agent Disconnect the system from AC power before servicing and when not in use Safety information 5 This system is not waterproof and should not be exposed to wet outdoor conditions Do not immerse in water or any other liquid Do not expose to high pressure water jets Do not spill fluid over or inside the system If fluid is spilled disconnect AC power and clean with a damp cloth If fluid is spilled onto electronic parts take the system out of service and contact Martin for advice Do not remove the covers or attempt to repair a faulty system Refer any service not described in this manual to Martin Do not operate the system if any parts are damaged defective or missing Moisture and electricity do not mix Do not aim fog output at electrical connections or devices Preventing bu
16. eight of all the devices they support If suspending from a rigging structure fasten the system to a rigging clamp Do not use safety cables as the primary means of support If the system is installed in a location where it may cause injury or damage if it falls install as directed in this manual a secondary attachment such as a safety cable that will hold the system if a primary attachment fails The secondary attachment must be approved by an official body such as T V as a safety attachment for the weight that it secures must comply with EN 60598 2 17 Section 17 6 6 and must be capable of bearing a Safety information static suspended load that is ten times the weight of the system and all installed accessories e Check that all external covers and rigging hardware are securely fastened e Block access below the work area and work from a stable platform whenever installing servicing or moving the system e Do not operate the system with missing or damaged covers or shields e Inthe event of an operating problem stop using the system immediately and disconnect it from power Do not attempt to use a system that is obviously damaged e Do not modify the system in any way not described in this manual or install other than genuine RUSH by Martin parts e Refer any service operation not described in this manual to a qualified technician e Fog output can cause condensation Do not point the output at smooth floors Floors and
17. id ied etas e etie eege iki BEL awl ae aired 26 Fuse replacement ide ondak a 26 Troubleshooting ee ap ERA pU 27 Te EE 28 Resetting the system after fluid out 28 Specification de 29 4 Contents Safety information Read the safety precautions in this manual befor installing operating or servicing this product The following symbols are used to identify important safety information AA A A Caution Safety Caution Burn Danger Caution Fire hazard Risk of hazard Hot Hazardous hazard severe injury or surface Do not voltage Contact death touch will cause electric shock Warning This product is not for household use It presents risks of injury due to electric shock burns falls and respiratory problems Read this manual before operating the system follow the safety precautions listed below and observe all warnings in this manual and printed on the system Use the system only as described in this manual and in accordance with local laws and regulations If you have questions about how to operate the system safely or if you have followed the instructions in this manual and the system is malfunctioning please contact Martin Service Preventing electric shocks Always ground earth the system electrically Use only a source of AC power that complies with local building and electrical codes and that has both overload and ground fault protection Before connecting the system to power check that the voltag
18. isit the Martin website at http www martin com If you have any questions about how to install operate or service the fixture safely please contact your Martin distributor see www martin com distributors for details or call the Martin 24 hour service hotline on 45 8740 0000 or in the USA on 1 888 tech 180 Safety information 7 Product overview The RUSH Club Smoke Dual is a top of the range atmosphere system from Martin Professional featuring multiple remote fog or haze heads with a base pump fluid unit Its remote heads allow the base unit to be conveniently located for fluid refill while the heads can be positioned in the ideal location for even fogging or hazing of the venue Designed using the latest fog system technology the RUSH Club Smoke Dual is capable of generating a variable level of fog or haze from up to 6 heads controlled in pairs which are connected using a simple push together fluid line and a single control cable Congratulations on your purchase of the RUSH Club Smoke Dual from Martin Details of the full range of Martin products are available on our website at www martin com Features at a glance 1 6 Fog or Haze heads per system Flying hanging brackets as standard Continuous output Water based fluid with long hang time Low noise Lightweight Variable output control for each head pair using DMX 10 liter 2 64 US gal fluid capacity Out of Fluid sensing using pressure sensor Valved out
19. l will stay on if operation channel 4 returns to Zero DMX control Default value 0 Default value 0 Default value 0 Default value 0 Fog fluid types AN The RUSH Club Smoke Dual must only be used with RUSH Club Smoke Dual Fluid Martin supplies high quality fog fluids that are based on ultra pure deionized water No other fluid is suitable for use To find your local dealer visit www martin com DANGER The RUSH Club Smoke Dual can run safely only on the specific fog fluid it is designed for Use ONLY the Martin fog fluid designated in this manual NEVER use any other type of fluid or toxic gas may be produced You will probably also cause damage to the system that will invalidate the product warranty Do not dilute fog fluid with water or any other liquid Discard fog fluid if it becomes contaminated Fog fluid types 25 Basic service 26 Before servicing the RUSH Club Smoke Dual read and observe all the precautions listed in Safety information on page 5 Any service not described in this section must be carried out by a Martin service technician To find your local Martin service centre visit www martin com Excessive dust fog fluid and dirt build up will degrade performance and cause overheating and damage to the system that is not covered by the product warranty To maintain adequate cooling dust must be cleaned from the outer casing and air vents of the system periodically
20. mply with the requirements for safe operation listed on page 5 e the fluid is one of the genuine Martin fluids listed under Fluid options on page 25 e the system is electrically grounded earthed e the AC power distribution circuits and lines are adequately rated for the current load Turning on the power Ensure the power switch on each head is turned on Turn on the main power switch on the base unit located next to the power inlet The display will show HEAT If the display shows OFF go to the RUNF menu on the digital control panel and set the option to CONT The system will remember its state from when it was turned off last time so it will only power up in OFF mode if you have previously disabled the heaters After about 6 8 minutes if no DMX is connected the display should show CONT and the system will begin producing fog If the display shows RDY go to the RUNF menu and set the option to CONT to start fog If DMX is connected the display will show DMX when the system is ready Each head has a red and green light on the side to indicate heating status RED Heating GREEN Ready Once the Ready light has come on the head will continue to heat for a time and the heater will cycle on and off to maintain the temperature will need to prime the system See section Priming system with The first time you run the system after connecting fluid pipes you Quick access buttons on page 19 Installation and setting up Con
21. o ut tet 8 Features ata glance Ai 8 Prodtct delails uet te eet o eed t e o ettet ce e tret 9 QUICK StA usine e eaa a e RU E RERUM DRE A da 12 Seting UD sei E 12 Making fog and hare A 12 Installation and sating UP asinan edna tetuer ii 13 lA A A 13 Lee 13 Setting dp iioc eto e d oto baee P DA e Et Ee mk E 14 Fna ene 16 Turning onthe POWA erioa dok eid e TH HER i sa eo dS dau ee RE de 16 Control sellings o e od Rt P EU Rte D det Pete dealer 17 EE 17 Setting Fog RUN modes e PIER ERE E e LEER dd ERE TERRE eine 17 Setting output density for Fog heads aanaaaaaa kaan kaaa kaan sienne einen innen nennt nnns 17 Setting Haze Run mocdes AAA 17 Setting output density for Haze heads kana kaan sss esistente ente enn nn 18 Setting the TIM ii 18 Setting the DMX base adress 18 Setting the master slave link mode vanka kaan kann annkkaaak aa einn nen ener renen ennt enn ener 18 Priming the system after fluid out 18 Priming system with Quick access buttons sessi esistente 19 Resetting options to factory settings A 19 Remote control iiec dag ee eie aen 21 OVE EW i 21 FUNCIONS ELM 21 TE E 21 DMX Control oec Dre t o e ean Doe e cte e p eb ie hi 23 o A M 23 Connection EE 23 DMX TUNCHONS E 23 FOO gile give Kate mmm mamom vaj e ee e ees e e Eee e ei 25 Lee 26 Cleaning n
22. put connectors on pump unit On board DMX 3 pin and 5 pin User friendly on board control panel Optional external fluid connection and Digital Remote Control Use only Martin RUSH Club Smoke Dual Fluid Use of other fluid o will void warranty Product overview Product details Fog Head Control input from pump unit Control link output to next head ains power switch Mains inlet cable Heat red and Fluid pipe Ready green connection indicators Fog output nozzle WARNING High temperature vapour and surfaces Product overview 9 Haze Head Control input from pump unit Control link output to next head ains power switch Mains inlet cable Heat red and Ready green indicators Fluid pipe Haze fan inlet connection D tw Qu S Haze output A port WARNING High temperature vapour and surfaces Product overview Base pump unit AVR program Fluid upload socket CODO and status LEDS connections to outputs to Bx ee heads heads Power inlet connector 3 pin DMX Main power input and switch link Digital remote plug Hinged door to fluid tank compartment 5 pin DMX input and link Digital control panel Product overview 11 Quick Start 12 You are no doubt eager to switch on the system and try it out by making a lot of fog This section tells you how to do that However please also make the time to read the s
23. rns and fire The fog produced by the system is hot enough to cause burns when it leaves the nozzle and very hot droplets of fluid escape occasionally Keep people and objects at least 60cm 24 inches away from the fog output nozzle Do not touch the fog output nozzle during or after use it becomes extremely hot and remains hot for several hours after the system has been shut down Fog output contains glycol a flammable alcohol that burns with an almost invisible blue flame Do not point fog output at sources of ignition such as open flames or pyrotechnic effects Do not attempt to bypass thermostatic switches fluid sensors or fuses Replace fuses only with ones of the type and rating specified in this manual for the system Provide a minimum free space of 100mm 4 inches around the system Provide a minimum free space of 500mm 20 inches around fans and air vents and ensure free and unobstructed air flow to and around the system Keep the system at least 60cm 24 inches away from combustible and heat sensitive materials Do not operate the system if the ambient temperature Ta is below 5 C 41 F or above 40 C 104 F Do not operate the system if the relative air humidity exceeds 80 Preventing injuries Fasten the system securely to a fixed surface or structure when in use The system is not portable when installed Ensure that any supporting structure and or hardware used can hold at least 10 times the w
24. surfaces may become slippery Check these frequently and wipe dry as necessary to avoid any danger of slipping e Ensure at least 2 m visibility in areas where fog is being produced e Fog fluid contains food grade glycols in solution but may present health risks if swallowed Do not drink it Store it securely If eye contact occurs rinse with water If fluid is swallowed give water and obtain medical advice e This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Preventing breathing problems e Asystem can operate safely only with the fog fluid it is designed for Use the system only with fluids specified under Fog fluid options on page 25 or you may cause the release of toxic gases presenting a severe health hazard You will also probably damage the system e Do not create dense fog in confined or poorly ventilated areas e Do not expose people with health problems including allergic and or respiratory conditions such as asthma to fog output e Do not point fog output directly at a person s face or at face height For the latest user documentation and other information for this and all Martin products please v
25. tandby Timer mode or Continuous mode Use the Menu Previous Next buttons to select the KLIN H option Control settings 17 18 uv Y Use the Up Down buttons to select 5 THY 1 Press the Enter button to store the setting The display shows 5 E T ME OUNT me Lerma Setting output density for Haze heads Use the Menu Previous Next buttons to select the HH ZE option Use the Up Down buttons to select the density from 4 Wm X Press the Enter button to store the haze setting The display shows E T Setting the Timer Select the TIME option from the RUN menu Then set the TRUN and TOFF values from the menu The TRUN and TOFF values are set in seconds and are in the range 0 99 The Fog and Haze values are taken from the menu settings for Fog and Haze The timer will cycle continuously until the run menu is changed Use this mode for maintaining a low level of fog in smaller venues When the timer is running and the display is not showing a menu the display shows TRUN or TOFF as the timer cycles between run and off modes Setting the DMX base address Use the Previous Next buttons to select the H I I F option Use the Up Down buttons to set the DMX base address from Vi 1 to 5 you hold down the button the address will count up or down Press the Enter button to store the address setting The system will automatically respond to a DMX controller whenever it is connected Eu La When using in a D
26. te control opeke ertet brian instant or timer controlled output 0 10096 adjustable output level DMX channels EE 4 DMX compllance gece ote nies bana a a did dia USITT DMX512 A Construction HOUSING EE Steel amp aluminium Heat exchangers fog heaa 1150 W EU 1000 W US direct thermal protection Heat exchangers haze head 900 W direct thermal protection Fluid system EII PUMA ta een ef meon Oscillating piston high pressure Onboard fluid capacily essen 10 litres 2 64 US gal Compatible fluids A RUSH Club Smoke Dual fluid Installation Orientation EE Floor or flying kit Max distance from pump unit to fog Heads AAA 50m Max distance from pump unit to haze heads sene 10m Max height difference between pump units and heads ssss 10m Connections Power connection base IEC Power connection heads AA Hardwired Specifications 29 DMX Calas a te ees 3 pin and 5 pin XLR sockets Remota control t peti a e es 3 pin locking XLR Electrical AC power EU MOAEIS ooooococonccinocicionccconccoconcccnnanann 220 240 V nominal 50 60 Hz AC power US modelsl 115 125 V nominal 50 60 Hz Main fuse in heads 220 240V power seen 6 3A T 250 V Main fuse in heads 110 120V power seen 10 AT 125 V Main fuse in base pump UN It aaa vana akan eene 3 15 AT 250 V Typical Power and Current Fog head EU model ie e eue aa dE
27. trol settings Overview The digital display on the side of the base unit allows you to configure the system using option menus Digital display Enter store button Menu previous next Value down up buttons buttons Quick access buttons PRIME1 PRIME2 PRIME3 PRIME BASE The brightness of the display can be changed to LOW NORM or HIGH using the DISP menu option Setting Fog Run modes The RUNF menu sets the operational mode of the Fog heads in the system and can also be used to shut down the heaters in the heads Settings are Off shutdown heaters off Standby heaters remain on Timer mode or Continuous mode n I L Use the Menu Previous Next buttons to select the RUNE opti Use the Up Down buttons to select E FF STEHY TIME Press the Enter button to store the setting The display shows 5 E rio hk T moa FA Selecting OFF will disable the heaters on the unit Setting output density for Fog heads nn Use the Menu Previous Next buttons to select the F Dt option Use the Up Down buttons to select the density from 4 A i Press the Enter button to store the fog setting The display shows SET Enter The fog setting will go back to its stored value next time the If you want to temporarily change the fog density do not press system is powered up This applies to all options Setting Haze Run modes The RUNH menu sets the operational mode of the Haze heads in the system either S
28. vice for assistance Setting up Fill the fluid tank only with Martin RUSH Club Smoke Dual Fluid see page 25 Up to two heads of the same type fog or haze may be connected to each fluid output of the pump unit Push the fluid tubing into the connections on the head and the pump unit and secure on the heads using the locking screw If two heads are being connected to an output a T connector must be fitted in the fluid tubing connect them to channel 1 o It is recommended that if you are using Haze heads you should Connect the RJ45 control connection on the heads to the pump unit If two heads are being connected to a channel use the RJ45 link output on the first head to connect the second head The RJ45 connectors are linked together internally and either can be used as input or link Connection of single head Installation and setting up Connection of two heads on one channel T connector Connection of fully loaded system Haze heads on channel 1 T connector Installation and setting up 15 If DMX control is being used connect the base unit to the DMX line see page 18 If the Digital Remote is being used optional accessory connect the remote to the Remote socket see page 9 Final checks Before applying power to the system verify the following e the system is safely located or installed and meets the location requirements stated on page 13 e the operator is familiar with and able to co
Download Pdf Manuals
Related Search
Related Contents
- All IT eBooks Additional Warnings 06 ver1_German.pub Integrated portable electronics tester 取扱説明書 1 USER GUIDE LFS TWO-QUARTER AND FIVE JVC LVT0911-001A User's Manual Sony S2 User's Manual Mobile Panel 277F IWLAN V2, Mobile Panel 277F IWLAN Informe de Progreso Técnico y Financiero Donaciones para la Copyright © All rights reserved.