1. o The duration of the program phase cleaning is increased with this option by approx 26 minutes This option doesn t influence the program cycle in the phases hot rinse and drying In the program Normal 65 C an additional 2nd intermediate rinse is run as already available in the Intensive program Option reduce increase temperature Chooseable to all programs except Prewash Quick Glass program and Energysaving Important Per device it is only possible either to increase or to decrease the temperature by an option button This has to be carefully watched when building variants This option exclusively influences the temperatures in Prewash and Cleaning The temperature in Hot Rinse remains unchanged The value for temperature in or decrease is stored in EEProm and therefore changeable for different variants Option tablet program Chooseable to all programs except Prewash Quick and Glass program To better dissolve the tabs and additional temperature step of 40 C is added in the cleaning phase Due to this the time of this phase is increased by approx 5 minutes TSE N 10 00 A B 34 599 508490 EN 27 Rinse resin wash regeneration and measure rinse Always when activating the circulation pump and or the interheater refilling of water is enabled o But the maximum refill time is limited to 60 seconds o Exceeding this limit causes a failure code di
2. Timeout for filling Failure recognised if What happens O LD9 Se e 1 after 2 min of static filling Progr LED blinking Program stopped Closed water ta LD10 y s y 2 after 4 min of total filling After removing the failure the program can be continued P blinking highlighted O LD11 9 HI 3 after 1 min of dynamic refilling during heating phase bei pressing button SO OFF ON the switch point of the pressure switch wasnt reached O LD9 ee s Progr LED blinking Program stopped Drain pump O LD10 y WW Pressure switch didn t reach the switch back after 2 drain cycles After removing the failure the program can be continued blinking highlighted bei ing button S0 OFF ON CH LD11 ei pressing button O LD9 Program interrupted i i for 1 i yes yes Floating switch detects water in the bottom tray Inlet valve closed and drain pump activated or 1 drain cycle Aqua Control O LD10 blinking highlighted Debounce time 2sec approx 1min O LD11 After removing the failure the program can be continued bei pressing button SO OFF ON LD9 eko P h f the h Heating CH LD10 m yes Target temperature not reached after a timeout of 45 min rogram is terminatga GE th obie heating e LDT highlighted Only possible in temperature controlled heating steps Al healing steps last 45min ingeniera LD9 ae NTC short circuit or interrupt Program is terminated without activation of the heati
3. issia ae visto deducts augectenten E EE ENARA 15 9 New pulse wash with random Functional 15 GA CUI ALON ME EE 16 Function of the new pulse wash with random functionality 0 eeee 15 10 Sequence draining with pressure switch level check 17 New drain with Sequence draining ccccccceeeeeeeeeeeceeeeeeeeeeeeeetnnnnteeeeeeeeeeetees 17 DEAIMING eenen cyecnosteeechergentt a E E A E E E nesbenestinnaeses EEEN e 18 11 Installation of the Drain Hose 0 0 0 0 ieee cccee eee eeeeetttteeeeeeeeeeeeenttntseeaeeeeeeeeenee 19 AZ Re enerati n NEE 19 RINSE OUL Aner TEGSMSCA ON EE 20 REGEN ALOR ee anette startet EE 20 13 In and Output element 00 ccc ceccceecceecce ec ee eects ceeeceeecaeecaeeaeeeaeeeaeeseeeeaeeeaees 21 Position of pushbuttons LEDs and lamps cece cece eeeeeeeeeeeeeeeeeeeeeeeeeeees 21 WA q en D ET 22 15 Input Philosophy Choose program and Options ccccccccccceeeeeeeeeeeeeeeeaees 23 16 Input Philosophy Programstart till end 0 2 ccc cee cece ccc eeceeeeeeeeeeeeeeeeeeeeaees 24 17 Input Philosphy delete change abort 2 e eee ee eect ee eeee sees eaaeeaes 25 18 Program phase display Status display ccc cee cece cee eeeeeeeeeeeeeeeeeeeeeeeeaes 26 TS PRAISE WATER ege 2 ences ahes neenon EaR wee se awit RER 27 20 Service functions for assembly line cece cece eeeeeceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 28 Assembly line test program 0 0
4. 0 0 ccc cece cece cece eee eeeeeeeeeeeeeeeeeeeeeeteneseneeeeeeeees 28 ST CUSTOMErSENMICE TUNCTIONS geet donna onruacsie sions E ele 29 Single actor activation missin nee a E a aa e EES 29 Indication of customer service failure stack 29 Delete the customer service failure stack and LED test ees 30 22 Misuse and program interrupt ccc cece eect eee te ee tee etre tenet eeeeeeeteneeeeeeeees 30 23 Overview of Service and After sales functions cece cece eceeeeeeeeeeeeeeeeeeeeees 31 24 Overview of failure displays cceceeeececeeeeeeeeeeceeeeeeeeeeeeeeseeeeeesteeeeeeetieeeeeeees 32 25 Programms and Options E 33 26 Description of the Options esi iana e e ea 34 27 Rinse resin wash regeneration and measure eee ec eeeeeeeeeeeeeeeeeeeeeeeeeees 35 TSE N 10 00 A B PAn 599 508490 EN 1 Dimensions Build in dimensions for Fully Integrated Build in dimensions for Integrated Dishwashers Dishwashers OKO FAVORIT OKO FAVORIT a k 820 870 S 110 100 40 X 175 Appliances with height adjustable feet N Plinth height for appliances 820 mm high 30 100 175 mm we Plinth height for appliances 870 mm high 150 230 mm 116 Build in dimensions for Built Under Dimensions for Freestanding Dishwasher Dishwashers Height 85 cm KO FAVORIT Width 60 cm Depth 60 cm Height with worktop removed 82 cm Feet adjustment 1 cm 4i Appliances
5. Inlet valve 13 2 Air break 14 3 Regeneration water dosage 15 4 Overflow safety level 16 5 Safety overflow 17 6 Inlet to sump from regeneration dosage 18 chamber 19 7 Regeneration dosage chamber 20 8 Softener 21 9 Salt container 22 10 Non return valve salt container 23 11 Regeneration valve 24 12 Safety inlet hose TSE N 10 00 A B 20 Base tray Float switch Pressure switch Filter Circulation pump Flow heater Drain pump Non return valve Spray arms Roof mounted shower Tub vent Sump assembly 599 508490 EN 13 In and Output elements Position of pushbuttons LEDs and lamps for appliances with vertical position of buttons left side of the panel right side of the panel LDO for appliances with horizontal position of buttons left side of the panel right side of the panel LDO TSE N 10 00 A B 21 599508490 EN 14 General Panel equipment Separate On Off switch SO 6 pushbuttons S1 S6 for choice of programs and options All pushbutton functions can be adjusted free without limitations by personalisation at PNC Level The pushbuttons S1 S3 and the LEDs LD1 LD3 are mandatory Necessary for the control of the service functions 3 step Program Phase Display PPD with LED s LD9 LD11 Actually planned indication of the LED s Clean Dry End Optional equipment for variant handling 3 step start time delay STD displayed with the LED s LD6 LD8 The delay ste
6. Si iC i A By pressing button S1 JO 10 i La IO 10 the value is changed e n Hitklng en SS E The valus is increased scrolling LOE On Wi p Seet highlighted e 1O 10 g wO 10 d g B For acknowledge the LED LD1 Seet eee e e i is switched ON for Ke E approx 5 seconds repeat blinking c eXHLx blinking d water hardness display until wii 10 poo H c The new value is then shown EE 1O 10 3 by the coded blinking of LED LD1 1O 10 a 1O Ont SEENEN 10 10 1 Each additional button S1 activation 1O 10 H increases the value scrolling E aa ee ny dai WH1 WH5 OFF after 60sek automatically EH cr Store adjusted water hardness E i i 1 The updated value is stored immediately after each successful input H 1 j Ga 10 10 1 J zo OFF by manuell activation On Off Terminate this function Automatically 60 sec after the last activation of button S1 or by switching the device OFF by the ON OFF button SO this special program is terminated TSE N 10 00 A B erage 599 508490 EN 20 Service functions for assembly line Assembly line test program Press program buttons S1 and S3 simultaneous and keep them pressed until the device is switched ON by the ON OFF switch SO For acknowledge that the function assembly line test program is active LED LD3 is blinking This LED keeps on blinking during the whole program cycle The program starts automatically after 3 sec This specific assembly
7. and keep them pressed until switching the machine on with the ON OFF button SO For acknowledge that the function is active the LEDs LD1 LD2 and LD3 are blinking By pressing the program button S1 the function is started During the whole cycle LED LD1 is blinking The failure code is displayed by PPD LEDs LD to LD11 see chapter Overview of failure displays The failures can be displayed scrolling by repeatedly pressing button S1 In maximum the last 3 occured failures can be shown The function can only be terminated by switching the machine OFF with the ON OFF button S0 TSE N 10 00 A B 29 599 508490 EN 22 Delete the customer service failure stack and LED test Press program button S2 and S3 simultaneous and keep them pressed until switching the machine on with the ON OFF button SO For acknowledge that the function is active the LEDs LD1 LD2 and LD3 are blinking By pressing the program button S3 the function is started Attention By starting the function the failure memory is cleared automatically All LEDs on the panel max LD1 to LD14 are switched ON simultaneous for approx 1 se cond The activation of the LEDs is repeated twice with a pause of 2 sec inbetween Afterwards the function is terminated The function can only be terminated before by switching the machine OFF with the ON OFF button SO Misuse and program interrupt Parallel activation of 2 or more buttons I
8. figure 3 take off base carefully and release circulation pump electronic and heater relay 4 disconnect the float switch With base removed the circulation pump 1 is accessible TSE N 10 00 A B 9 599 508490 EN 5 Water Course Scheme Inlet valve Air break Regeneration water dosage Overflow safety level Safety overflow Inlet to sump from regeneration dosage chamber Regeneration dosage chamber Softener Salt container 10 Non return valve salt container 11 Regeneration valve 12 Safety inlet hose OO P ob OO OO TSE N 10 00 A B 10 Base tray Float switch Pressure switch Filter Circulation pump Flow heater Drain pump Non return valve Spray arms Roof mounted shower Tub vent Sump assembly 599 508490 EN 6 All Around Water Protection Aqua Control Inlet Hose The inlet hose has a double wall construction The inner hose is equipped with a flow restrictor built into the tap connection and has a flow rate of 4 litres per minute The inlet valve 1 is located in the base of the dishwasher The safety outer hose 12 is connected to the regeneration chamber If the inner hose should burst the water passes into the tub The safety pressure switch activates the drain pump and decreases the waterlevel down to normal level An additional overflow protection is a defined overflow through the regeneration chamber The water flows into the bottom tray and activates the float switch which
9. led to the circulation pump Function of the new pulse wash with random functionality After the filling steps the circulation pump is running at two rotational speeds Pulse Wash Pulse time 2800 1 min Pause 1600 1 min Use with Wash Cycles Definitive Time Random Time Definitive Time Random Time 0 0 3 sec 0 1 5 sec prewash intensive wash intensive 0 0 3 sec 0 1 5 sec wash and intermediate wash prewash normal The ratio of pulse time and pause is always 1 5 TSE N 10 00 A B 16 599 508490 EN 10 Sequence draining with pressure switch level check S MI 1 draining sequence with variable timing level check GE on off T1 variable T2 variable T3 variable Drain Cycle T1 T2 T3 First draining before every wash cycle 45 sec 15 sec 20 sec New draining with sequence draining The draining step contains of 3 time sequences In the middle sequence during time T2 the drain pump is stopped At the end of the drain step the water level is checked If the switch back is reached the drain step is terminated If the switch back isn t reached the drain step is repeated A failure code is displayed if after 2 drain steps the switch back couldn t be reached In this case the program is stopped and PPD LED LD10 is blinking O LD9 LD10 O LD11 TSE N 10 00 A B 17 599508490 EN Draining During the wash cycle the water
10. line program simulats a normal wash cycle and run analogus The program phase is displayed by PPD LEDs LD9 to LD11 At least 3 seconds after power failure the full function is restarted The test program can be interrupted by opening the door During door open fe program LED LD3 is blinking and the related PPD LED is ON The test program can only be terminated by an additional activation of button S3 See also description Delete program At the end of the test program the LED LD3 is blinking and the PPD LED End is ON In the assembly test program the regeneration is run in any case not only depending on water consumption Adjust and recognise heating power The heating power is considered in the machine personalisation All machines equiped with EDW1000 will be build up with 10A heating element The assembly line test program takes approximately 16 minutes and proceeds as follows Program Run Display Stop Function Time up to Tevel enmetis filling pauses up to level circulation pump with dynamic filling increasing speed up to 1900 1 min circulation pulse 2 AN up to 50 C detergent dispenser dispenser Sane pause draining 10 sec regeneration 120 sec drain 30 sec DEE E E 7 TSE N 10 00 A B 28 599 508490 EN 21 Customer service functions Single actor activation Press program button S2 and S3 simultaneous and keep them pressed until switching the
11. non return valve 10 and enters the softener 8 where the resins are regenerated The softener has 5 settings and can be adjusted to suit the degree of water hardness The adjustment of the water hardness is described in the short list of service functions Table for water hardness adjustment Adjustment Water number of Opening hour for regeneration hardness water loads valve WH 1 4 dH 60 180 Sek WH 2 180 Sek WH3 180 Sek WH 4 180 Sek WH 5 50 dH 0 180 Sek This table is stored in EEProm Therefore the values are changeable by variant configuration The values on the left specify the actual status and shall only be seen as an example for this documentation Column Number water loads contains the value when the regeneration will be run o With each dynamic filling step during the cycle the counter is increased by 1 A possible refilling is not taken into consideration o If the value in the table linked to the adjusted water hardness is reached the regeneration is activated At the water hardness WH5 regeneration is done each cycle o In all DGN and ZM45 machines at the end of the program a 30 seconds draining of regeneration water is run TSE N 10 00 A B BER 599508490 EN Rinse out after regeneration After a regeneration at the end of the program the directly ensuing next wash cycle performs a rinse out This rinse out replaces the first pumping step of the wash program Regeneration 1
12. shown by the 3 LED s LD6 LD8 Only the LED of the choosen delay time is highlighted The choice is a scrolling function 3h 6h 9h OFF 3h 6 seconds after pressing the last pushbutton the timer for the delay time is started Within this 6 seconds besides LEDs for the selected program is highlighted Besides this PPD LEDs LD9 LD10 or LD11 are blinking During this phase PPD LEDs LD9 LD10 or LD11 are blinking During the run of the delay timer the program and delaytime LEDs are highlighted the PPD LEDs are switched off A change or cancelling all STD LED s off of the delay time is during the whole delay phase at any time possible TSE N 10 00 A B i 23 599 508490 EN Countdown of StartTime The StartTime is counted backwards beginning with the adjusted value until Oh Afterwards the program starts automatically see description on page B 4 subject Programstart The display is updated accordingly Sia Display of StartTime 9h O17 9h to 6h eu 6h to 3h O ips 3h to Oh 6h Om Oh Start Other values possible due to variant programming Si n O LD6 Each activation of a pushbutton with in the 6 seconds of the program selection time resets the timer for the program start where the pushbuttons are deactivated again back to 6 seconds 16 Input Philosophy Programstart till end Program start After the end of the selected StartTimeDelay time or
13. with height adjustable feet TSE N 10 00 A B 3 599 508490 EN 2 Typical features for use AEG INTENSIVE TIME o 70 SELECTION MN enn NORMAL l SCH 9h 65 50 NORMAL l PREJ BIO 50 WASH OKO FAVORIT EXxcLUsiV B CLEAN B DRY B END B SALT 0 DETERGENT OKO FAVORIT 50719 sensorlogic Wash programs Power consumption Heating Water consumption Energy Normal Bio 50 C Energy Normal 65 C Noise 3 Components Interference Filter The interference filter is connected in the terminal board parallel to the mains feed TSE N 10 00 A B Intensive 70 Normal 65 Normal Bio 50 Quick 50 Prewash Extra 10A flow heater 16 1 05 kWh 1 35 kWh 47 dB A 599 508490 EN Pressure Switch The pressure switch controls the water level Without water contact 11 12 is closed fN Switch point with level 65 mm Ws Reset point with level 45 mm Ws fS Switch point with safety level 114 mm Ws Reset point 90 mm Ws The pressure switch is not adjustable S ALAT 1S oi cam iN ad 12 Flow Heater The flow heater heats the water to the required temperature During the wash cycle water is contantly passing through the flow heater Power output 2100 W Resistor 25 Q Protector 98 C 5K Thermal fuse 260 C Circulation Pump The circulation pump is driven by an asynchronous motor with an auxiliary winding The auxiliary winding ist in circuit with a 4 mF capa
14. 490 EN 26 Description of the options Option half load Chooseable to all programs except Prewash If the choosen program has a phase prewash this phase is skipped The speed of the circulation pump is reduced in the filling step Reduction of average time are 28 minutes by intensiv programmes 18 minutes by programmes The water consumption is reduced about 5 liters Option rinse Chooseable to all programs except Prewash Quick Glass program and Energysaving An additional prewash phase is added to the program cycle Option superwash Chooseable to all programs except Prewash Quick Glass program and Energysaving Changes in the prewash phase not available in Eco 65 and Eco Bio 50 o hot prewash with higher temperature Temperature is increased from 40 C to 55 C o Two soaking phases of 5 minutes duration are added to the cycle Inbetween these phases the circulation pump is activated for a short time In this soaking phases the soil is softened and comes off o Additional prewash time of total 7 minutes is added During this time the temperature is kept on 55 C by enableing re heating o The duration of the program phase prewash is increased with this option by 18 20 minutes Changes in the cleaning phase o Additional 6 minutes of cleaning with heating to max 55 C o Additional 20 minutes cleaning with a controlled temperature of 70 C resp 65
15. 6 seconds after the last program or optionbutton activation the choosen program is automatically started From this time on a delay time or program option can no longer be choosen To select a delay time a restart of the machine is necessary Program run During the program run the following LED displays are highlighted o Pushbutton LED of the choosen program and options o Depending on the program phase the related PPD LED LD9 LD11 The program cycle is described separetely in chapter Program cycles Program end The End of program is displayed by PPD LED End The acknowledge LED of the program and if choosen of the option button s remain ON After reaching the program end the actual program can be deleted by either opening the door or switching OFF the machine by the ON OFF button SOQ If the program was deleted by opening the door the maschine is automatically in pre start mode if the door is closed again this means that immediately a new program could be choosen TSE N 10 00 A B 24 599 508490 EN 17 Input Philosphy delete change abort Delete program A selected and started program can be deleted at any time Therefore the pushbutton of the selected program has to be pressed as long 3 Sek until the related LED is switched off o During this time the program and possible option LEDs are blinking The program is aborted and deleted o Besides this the LEDs of all program and op
16. ED s LDO9 LD11 also different failures are displayed Status resp Indication displays Displays are available depending on the device variant The display is done mainly by the_LEDs LD13 and LD14 If necessary due to design reasons also other positions for the display are possible The display is realised by a permanent activation of the relevant LED The LEDs are ON beginning with the machine switched ON by the ON OFF switch SO till the start of the program this means also during a possible StartTimeDelay phase Besides this also from program end PPD LED End till switching OFF the device The display LEDs are switched OFF during the complete program cycle LED display SALT o ON if salt level is low o Switched off after adding salt Due to salt dissolution it can take some hours for switch OFF Comment LED Display Salt is switched OFF if waterhardness WH1 is adjusted no regeneration necessary LED display RINSE AID o ON if rinse aid level is low o Switched off after adding rinse aid TSE N 10 00 A B DG 599 508490 EN 19 Adjust water hardness General information The adjustment and change of the water hardness area is valid for all designs and button configurations For this function always the buttons SO 1 and S2 are relevant independent of their varying program functionality given by variant programming General In production line the pre adjustment is WH3 On WH1 no
17. GU Electrolux Technical Support Europe SERVICE MANUAL DISHWASHER 210 ri SICH O O 219 410 eI IO AEG INTENSIVE TIME ze SELECTION NORMAL J O 65 NORMAL J O PREY O BIO 50 WASH MADE IN GERMANY AEG Hausger te GmbH Muggenhofer Stra e 135 D 90429 Nurnberg Germany Fax 49 0 911 323 1420 TSE N Edition 10 00 OKO_FAVORIT Exclusiv C B DETERGENT Dishwasher EDW 1000 Mini Tronic Publ Nr 599 50 84 90 685 EN Index 1 Dimensions ee 3 2 Typical features for USC 2 0 0 0 ceeeceeeeeeeeeeeeeeeeeeeeeeeeeeeceeecsasaaeseaeaaaeaaaeaaaaaaaeaaaeaaes 4 3 e leen En CEET A Interference GE 4 PreSSUre Switch a E A ETT T 5 Fow Heat niesiona ae a e EAE E E E he ger 5 Circ lation PUMP ee A e E 5 Drain PUMP EE 5 NTC Temperature Sensor 0 cc ci rrrrrerrererrrrtrrrerrrttrrtrererrrr terrre ett 6 Detergent Rinse Aid Combination Dispenser Un 6 Ee OO nee AE ot Mal seid Lots dies a AN 6 Water Sonen ing EE 7 4 Position of Components 32 oneal eie eae eee aide ale aS as 7 5 Water Course Scheme mimin a EE ane EAR EAR die 10 6 All Around Water Protection 0 c ccc tc i ii iiieeeeeeeeeeeeeeees 11 Aqua Conttrol Inlet Hose erne A E r E S 11 e EE 11 Leakage Protectio isise a avn e E E A E A E inden g dues Er Eei 11 7 Water lets 22 egen Der ee e a a a 13 8 Water lOad SLEDS issiciscseuleieudegestvnete A E E Ree Re 14 SEMIS TING ee E E E T A 14 Dynamic TUNG
18. The machine is in Prestart mode o All program and option buttons are active and can be choosen Now choose of StartTimeDelay possible The selection of the STD can be done with the predefined pushbutton This button hasn t an acknowledge LED The activated delaytime is shown by the 3 LED s LD6 LD8 Only the LED of the choosen delay time is highlighted The choice is a scrolling function 3h 6h 9h OFF 3h A change or cancelling all STD LED s off of the delay time is during thecwhole delay phase at any time possible As there s not yet a program choosen the selected STD value remains unchanged till a valid program is choosen and the LEDs are blinking Programs Options selection The user selects a program by pressing the defined pushbutton The LED of the choosen program is highlighted as a acknowledge Within 6 seconds the user can change the program or choose one or more possible options During this phase PPD LEDs LD9 LD10 or LD11 are blinking Activation from options or StartTimeDelay STD is only possible before programm start Select options possible Press related option button Only predefined permissible combinations are accepted If the selected option is accepted the LEDs of program and option button are highlighted Within 6 seconds additional options are selectable Select StartTimeDelay possible The selection of the STD is done with the related pushbutton The activated delaytime is
19. citor A tacho generator is used for speed control There are three speeds for rinsing 2800 1 min 2200 1 min 1900 1 min 1700 1 min 1600 1 min Power output 50 W Drain Pump The drain pump is driven by a synchronous motor Power output 26 W Pump rate 15 I min TSE N 10 00 A B 5 599 508490 EN NTC Temperature Sensor NTC Temperaturfuhler Temperature sensor NTC resistor Temperatur Widerstand temperature resistor nur bei vollelektron Geschirrsp ler only for fully electronic dishw asher Q Q Q Q Q Q Q Q Q Detergent Rinse Aid Combination Dispenser Unit Detergent dosage 20 ml 30 ml Rinse Aid capacity 150 ml Dosage settings 1 6 Quantity 1 cm 6 cm The detergent dispenser is activated by a release coil The first operation adds the detergent and the second the rinse aid If the door is opened the latching bar is reset to the detergent dosage position Electronic On electronic models a micro processor controls all components this is done using triacs The electronic also memorizes all programme data The heating is switched by a relay on the electronic board TSE N 10 00 A B 599 508490 EN Water Softening The components required for water softening 1 softener unit 2 regeneration dosage chamber The incoming water flows through the softener which works according to the ion exchange principle The ion exchanger is filled with small epoxy resin balls The resins exchan
20. energises the drain pump This drains the dishwasher preventing water damage Safety level If the safety level is reached by over fillling the safety pressure switch starts the drain pump The water is only drained until it has reached the normal level because the reset point of the safety pressure switch is above the switchpoint of the normal pressure switch Leakage Protection The anti flood switch in the base tray will activate the drain pump and drain the water from the tub in the event of an internal leakage If the float switch is activated all electric components are switched off except the electronic and the drain pump TSE N 10 00 A B 11 599508490 EN All Around Water Protection Inlet valve Air break Regeneration water dosage Overflow safety level Safety overflow Inlet to sump from regeneration dosage chamber 7 Regeneration dosage chamber 8 Softener 9 Salt container 10 Non return valve salt container 11 Regeneration valve 12 Safety inlet hose OO P ob A TSE N 10 00 A B BER Base tray Float switch Pressure switch with safety level Filter Circulation pump Flow heater Drain pump Non return valve Spray arms Roof mounted shower Tub vent Sump assembly 599 508490 EN 7 Water Inlet The water flows into the regeneration dosage chamber 7 via inlet valve 1 over air break 2 into regeneration dosage chambers 3 into softener 8 At this point the water divides 1 4 of the wate
21. ge the hardness constituents calcium and magnesium for sodium ions When all the sodium ions are used up it is necessary to regenerate the softener This is done by flushing a brine solution through the softener Afterwards the softener is washed out with fresh water and is now fully effective Depending on the water hardness regeneration is only necessary after several wash cycles The softening system is designed for a water hardness of up to 50 dH 4 Position of Components Detergent dispenser 1 Drying fan intake vent 2 Spray arms 3 Detergent dispenser 1 2 Electronic 2 TSE N 10 00 A B 599 508490 EN Thermal sensor 1 Drain pump 2 Pressure switch 3 Flow heater 1 Terminal board 2 Inlet valve 3 To remove side panel 1 Remove fixing screws 2 Pull the panel away from the rear and gently out of the front trim Removing the regeneration dosage chamber 1 disengage locking tabs 1 2 disconnect hoses 2 3 holding the top of the chamber pull upwards disengaging it from the softener TSE N 10 00 A B Oe 599 508490 EN Removing the softener unit 1 remove the securing nut located under the salt cap 2 press softener 1 down and remove it through the front from the base area 3 CAUTION if accessible release reed switch Removing the base 1 remove side panels rear panel and plinth panel 2 gently release base fixing clips with a screwdriver
22. is pumped out at various stages First the draining water cleans the filters 16 The filters are open at the bottom which allows any soilage to be rinsed off sufficiently There is a non return valve 20 at the inlet connection to the drain pump 19 This valve prevents the water 1 Inlet valve 2 Air break 3 Regeneration water dosage 4 Overflow safety level 5 Safety overflow 6 Inlet to sump from regeneration dosage chamber 7 Regeneration dosage chamber 8 Softener 9 Salt container 10 Non return valve salt container 11 Regeneration valve 12 Safety inlet hose TSE N 10 00 A B 13 14 15 17 18 19 21 22 23 18 Base tray Float switch Pressure switch Filter Circulation pump Flow heater Drain pump Non return valve Spray arms Roof mounted shower Tub vent Sump assembly 599 508490 EN 11 Installation of the Drain Hose Drain hose connection Max permissible height 1 metre Min height required 30 cm above floor level The drain hose can be extended horizontally to a maximum length of 3 metres at a height of 85 cm 12 Regeneration The water chamber for regeneration 3 contains 350 ml water During regeneration the regeneration valve 11 is energized The 350 ml water runs into the salt container 9 and mixes with the salt to form a brine solution In the top of the salt container there is an opening with a small filter from here the brine solution passes through a
23. machine on with the ON OFF button SO For acknowledge that the function is active the LEDs LD1 LD2 and LD3 are blinking By pressing the program button S2 the function is started During the whole cycle LED LD2 is blinking The first component to be activated automatically is the inlet valve All additional actors can be started in the below mentioned sequence by pressing button S2 repeatedly Each of the single actors is switched ON for the below given time Afterwards he s automatically switched OFF In the following the machine remains in a PAUSE mode until the next actor is started by pressing button S2 or until the function is terminated The actual component is displayed by a code of the PPD LEDs The sequence of activation is fixed and scrolling It can t be changed The time of activation can be shorted by pressing button S2 already before the timeout of below given value Sequence of activation ON time and PPD code valve dispenser SESCH bimp neaund reset valve rEgEnNET SS SEH pump all OFF 20sek 60sek 20sek 60sek 60sek k LD9 O LD9 De LD9 O LD9 LD9 O LD9 LD9 O LD9 O LD10 OC ow DY LD10 O LD10 O LD10 LD10 LD10 O LD10 O LD11 O LD11 O LD11 LD11 LD11 LD11 LD11 O LD11 continue per hand activation Ge The function remains active until terminated by pressing the ON OFF button SO Indication of customer service failure stack Press program button S2 and S3 simultaneous
24. n of single _ e LD1 LD2 LD3 LD2 See DX S ipi Soe 5 ge b Ge Ces e gt gt ib D gt then afterwards a my r O LD11 O LD11 O LD11 D11 D11 L011 p11 O LD11 actuators blinking blinking continue per hand activation tate We Display Serice failure memory Delete Service failure memory Display test Stop the function S0 On Off S2 S3 then afterwards SO On Off S2 S3 then afterwards SO On Off LD1 LD2 LD3 blinking LD1 LD2 LD3 blinking LD1 blinking 3 times short activation of all gt available LEDs with 2 sec Pause inbetween chapter Single actor aktivation The failure is displayed coded by the PPD LEDs The stored failures can be scrolled through by pressing button S1 see description Indication of customer service failure stack and Overview of failure displays The customer service failure stack was delete chapter Delete the customer All service and after sales functions can only be stopped by switching the machine of with the On Off switch S0 Except Water hardness adjust Function is also terminated by a 60sec timeout after the last activation of button S1 Clear failure mem SUOI OUNJ S jesS JOY PUL BDIAIBS JO MOIAIBAC SE gt 9 vO00LN 2SL N43 06 78 0S 66S Failure Display PPD LED s Failure display visible for customer Visible in failure memory After sales Short description
25. n terms of electronic control an exactly parallel activation of 2 or more buttons is not possible in the practical use Button pressed too long with already running program If a program button is pressed for more than 3 seconds this can cause the running program to be deleted or changed see description Delete program change program If an option button is activated this causes no influence on the program run These buttons are deactivated after program start Failure during program run The failure is displayed by a blinking program LED and the blinking PPD LEDs according to the defined code see table LEDs of probably choosen options remain ON Removeable failure Water tap closed Drain pump blocked If the recognised failure is removeable by the user the machine automatically changes in a PAUSE mode As soon as the failure e g water tap closed is recognised the program is stopped in the actual step The control is waiting until the failure was removed if possible To continue the program the ON OFF button SO has to be switched OFF and ON The program cycle continues from the actual program step No program information is lost It s not necessary to delete the program Other failures All additional failures which are partly also visible for the customer by the PPD LEDs are listed in the table on page B12 in more detail Power fail If a power fail occures the machine sh
26. ng NTC Sensor O LD10 no hi e hted The NTC is controlled between the 1st filling and the start of the element gng drying cycle All heating steps last 45min in general LD11 O LD9 The program is interrupted Tach LD10 yes yes After activating the circulation pump within 30 sec no signal from By pressing the button SO OFF ON the program can be inkin ighlighte the tachometer is recognised restarted SC blinking highlighted he tach i ised tarted O LD11 Failure repeatedly occuring gt Service call LD9 The program is interrupted and water filled till the switch e F j d 3 oint of the pressure switch Circulation pump O LD10 yes l yes Signal from tachometer is recognised although the circulation By pressing the button S0 OFF ON the program can be Triac short circuit LD1 blinking highlighted pump isn t activated restarted Failure repeatedly occuring 6 Service call Wrong variant no no Checksum in EEProm not correct No program selection possible programming display no not possible Only recognised after switching ON On Off lamp LD0 on sKe dsip ainjiey JO MAIAIBAC PZ 25 Programms and Options Programs Flexible program_1 Flexible program_2 Intensiv 70 Intensiv 65 Normal 65 Normal Bio 50 55 Energysaving Superwash reduce increase temperature foe lefele i i Eat load Run Ooo Quick 50 Quick 40 Pre wash Line program TSE N 10 00 A B 33 599 508
27. opened during program run o By opening the door the program can be interrupted for any time without loosing information This is equal to a Pause function o After opening the door all displays remain ON except the PPD LED s LDOQ bis LD11 as long as the device isn t switched OFF by the ON OFF switch SO The actual PPD LED s are blinking as long as the door remains open o After closing the door the cycle continues immediately The door is opend after reaching the end of the program o If the program end is reached and the door opend the device is again in Prestart mode TSE N 10 00 A B 25 599 508490 EN 18 Program phase display Status display Program Phase Display PPD PPD has always 3 steps The PPD is realised by 3 LED s LDOQ LD11 The program phases are actually defined Clean Dry End The displayed phases are related to the program cycle During the program selection but before the real program start all relevant program phases are shown in parallel by blinking LEDs E g in the Quick program or in the Prewash program only PPD LED LDO9 is blinking in all other programs LED s LDOY and LD10 After program start only the LED for the actual program phase is ON The switch from one program phase to the following in done at the step change The display End PPD LED LD11 is not shown before the real program end when the timer has reached the end status With the PPD L
28. ows the same behaviour as if switched OFF with the ON OFF button On power return the machine shows the same behaviour as if switched ON with the ON OFF button The program continues from the last valid step No program information is lost The program continues after power fail without additional button activation TSE N 10 00 A B 30 599508490 EN aj po ee m Set eech e reg gen A e mee L ees ee L ee e Ze E Wa m LD1 LD2 LD3 LD4 LD5 LD8 Q LD9 z DS l geld ER O o O O O OrprOrnr0 E pel tong l O L6 Ou g 7I 1 OOOOQOO L sf t Us P LD3 l LD12 l s6 Le O LD14 D Vertical position of buttons Horizontal position of buttons E Ng _06 78 0S 66S Function Choose water hardness Activation of base function with button s S1 S2 then afterwards S0 On Off S1 S3 LED display LDI highlighted 5sek Afterw ards display of actual adjusted hardness by blinking Choose resp Start of function with button s LED display LD1 highlighted 5sek Afterw ards display of new adjusted hardness by blinking Code Start Short description Comment chapter Adjust water hardness The assembly line test program works automatically Assembly line LD3 LD3 test E ihenafteriards blinking gg ater 3 Sek gt blinking S0 On Off Automatically Assembly line test program TS yae eispenser areugonpumo heating resgtyalve regener dos arain pump alj OFF 2 Activatio
29. ps can be defined free depending on the variants on PNC level in production Every start time delay must has to be between 1 and 15 hours LED display for salt LED display for rinse aid Possible program options Superwash Start time delay Half load kleine Menge Temperature increase and or decrease Tablets program Additional rinse phase Extra rinse Other points Regeneration depending on water consumption Adjustment and display of water hardness via user interface Assembly line test program Different after sales functions Failure memory Single actuator mode LED Test Device specification for max Energylabel ABC No active drying with fan possible Water safety system with different variants and safety levels Also depending from external components Type of pushbuttons The On Off pushbutton SO is a separat power switch with toggle function All other possible pushbuttons S1 S6 are of push release type and directly on the electronic board Acknowledges and Displays All pushbutton acknowledges and all other displays are realised by LEDs The On Off button is the only one connected to a glow lamp instead of a LED with separat function directly indicate On Off TSE N 10 00 A B 22 599 508490 EN 15 Input Philosophy Choose program and options Switch ON the device Press On Off button SO to switch the machine ON Display LDO at the On Off button is highlighted o
30. r enters the tub through the vent 23 3 4 of the water enters the sump 24 through hose 6 The level control chamber built into the sump operates the pressure switch 15 Inlet valve Air break Regeneration water dosage Overflow safety level Safety overflow Inlet to sump from regeneration dosage chamber 7 Regeneration dosage chamber 8 Softener 9 Salt container 10 Non return valve salt container 11 Regeneration valve 12 Safety inlet hose OO P ob A TSE N 10 00 A B 13 14 16 17 18 20 21 22 24 BEER Base tray Float switch Pressure switch with safety level Filter Circulation pump Flow heater Drain pump Non return valve Spray arms Roof mounted shower Tub vent Sump assembly 599 508490 EN 8 water load steps static water dynamic water load a lad S to level with level control max 4 repetitions Timeout 2 10 Sek gt lt 5Sek D Sek lt aa Bee water levelcheck re displayed ot reached level check water d ca L Static filling Static filling until pressure switch point failure code If this point isnt reached after max 2 minutes Timeout 1 a failure code is displayed and the program is stopped The program phase display PPD LED LD is blinking LD9 O LD10 O LD11 TSE N 10 00 A B 14 599508490 EN Dynamic filling 10 seconds filling at reduced circulation p
31. regeneration is carried out No salt is necessary A possible Salt LED will not be activated Table for hardness areas Show with water hardness LED LD1 adjustment 41 50 dH 30 40 dH 19 29 dH 4 18 dH under 4 dH 5x blinking 4x blinking 3x blinking 2x blinking 1x blinking Button configurations vertically Lafe 1O o ww2I sz 10 9 3 DO 10 R i as oo o 9 3 LDO 0000 8 O i Si S2 o so Button configurations horizontally Call Change Store the value for water hardness LI ALO a a d go a l ens O Call function Water hardness adjustment IO 10 see E 1 Press at the same time button S1 and S2 and SE 2 Keep them pressed as long as the device is switched ON by SO e Steg on For acknowledge the LED LD1 Is switched ON miega l 3 for about 5 seconds O 10 GE 4 The actual value of water hardness is shown by the blinking of LED 3 p5sek highlighted LD1 ac 1g 3 In the example on the left by 3 times blinking the pre adjustment as x e i g done in production is shown oe el T 5 6 Then the LED is switched OFF for 5 seconds p3x blinking a i i i 4 recht O 2 3 ve After that this procedure is repeated continuously up to 60 seconds io Sr 3x blinking 5sec Pause 3x blinking 5sec Pause aso f SE 5 i per activation Change of adjusted water hardness Ri H H ON Ne E eg E a 0 dE a AL WO IO 4 f ef
32. splay and the program cycle is stopped PPD LED LD is blinking measure to cleaner and rinse aid The activation times of the dispenser were optimised with the EDW1000 o In program phase cleaning 30 seconds ON o In program phase hot rinse 30 seconds ON 30 seconds OFF 30 seconds ON The dosage of rinse aid is temperature controlled at a minimum of 50 C TSE N 10 00 A B ST 599508490 EN
33. tion buttons and the PPD LED s LDO9 LD11 are switched off o Only the Power lamp LDO at the On Off switch remains highlighted The machine is again in Prestart mode Change program after program start A change of the program during a running cycle can only be realised by using the function Delete program see above Program interrupt Pause Function With the help of the ON OFF button SO the program can be interrupted as long as one likes This is equal to a Pause function The same is valid for an interrupt by opening the door There is no delete function integrated in the ON OFF button SO If the program is interrupted by the ON OFF button all displays are switched OFF The program cycle is continued immediately after switching the machine ON again with the ON OFF switch respectively after closing the door No additional button activation necessary Special remark for steps with activate circulation pump The cycle continues with a reduced speed off the circulation pump for about 20 seconds All displays and acknowledges are shown in the same status as before the interrupt What happens on Opening and Closing the door see description Power fail Device is switched on and timer is in Prestart mode o After opening the door all displays on the user interface remain as they are The power supply of the timer is guaranteed as long as the device remains switched ON by the On Off switch SO The door is
34. ump speed 5 seconds pause 10 seconds filling at reduced circulation pump speed filling with increasing circulation pump speed As soon as the target speed has been reached it is filled up to the pressure switchpoint Failure code If this dynamic switchpoint isn t reached within total 4 minutes Timeout 2 the dynamic filling can be repeated 3 times Only after non successful repeating 3 times a failure code is displayed and the program is stopped The PPD LED LD is blinking D LD9 O LD10 O LD11 The target speed is dependent on the subsequent pulse wash pulse wash pulse 2800 1 min Pause 1600 1 min target speed in dynamic filling 1 0 9 sec 4 5 sec 2200 1 min 2 0 6 sec 3 sec 1900 1 min 3 0 3 sec 1 5 sec 1700 1 min 9 New pulse wash with random functionality Thigh r lt vandom function Jee time high speed random time J pressure switch point water level The variable speed is 1600 1 min at the moment and equal to all appliances TSE N 10 00 A B 15 599 508490 EN Random function time for high speed calculated with random funktion Ti hr a time for high speed cycle definition T random time Tisy time for low speed Ratio factor for low speed eeprom definition Circulation The circulation pump 17 pumps the water simultaneously into the ceiling shower 22 and into both spray arms 21 The water is filtered in the sieves 16 and