Home

VelociCheck Air Velocity Meter Model 9515

image

Contents

1. 1 Carrying case 2 Instrument Chapter 2 Setting up Supplying Power to the Model 9515 VELOCICALC Air Velocity Meter The Model 9515 is powered with four size AA batteries Installing the Batteries Insert four AA batteries as indicated by the diagram located on the inside of the battery compartment The Model 9515 is designed to operate with either alkaline or NiMH rechargeable batteries although it will not recharge NiMH batteries Battery life will be shorter f NIMH batteries are used Carbon zinc batteries are not recommended because of the danger of battery acid leakage Using the Telescoping Probe The telescoping probe contains the velocity and temperature sensors When using the probe make sure the sensor window is fully exposed and the orientation dimple is facing upstream NOTE For temperature measurements make sure that at least 3 inches 7 5 cm of the probe is in the flow to allow the temperature sensor to be in the air stream Extending the Probe To extend the probe hold the handle in one hand while pulling on the probe tip with the other hand Do not hold the cable while extending the probe as this prevents the probe from extending Retracting the Probe To retract the probe hold the handle in one hand while gently pushing on the probe tip with the other hand If you feel the probe antenna binding pull gently on the probe cable until the smallest antenna section is retracted Collapse the rest of the an
2. ENERGY AND COMFORT Ventilation Testing VELOCICALC Air Velocity Meter Model 9515 Operation and Service Manual q gt TRUST SCIENCE INNOVATION Copyrighto TSI Incorporated September 2007 All rights reserved LIMITATION OF WARRANTY AND LIABILITY effective July 2000 Seller warrants the goods sold hereunder under normal use and service as described in the operator s manual shall be free from defects in workmanship and material for twenty four 24 months or the length of time specified in the operator s manual from the date of shipment to the customer This warranty period is inclusive of any statutory warranty This limited warranty is subject to the following exclusions a Hot wire or hot film sensors used with research anemometers and certain other components when indicated in specifications are warranted for 90 days from the date of shipment b Parts repaired or replaced as a result of repair services are warranted to be free from defects in workmanship and material under normal use for 90 days from the date of shipment c Seller does not provide any warranty on finished goods manufactured by others or on any fuses batteries or other consumable materials Only the original manufacturer s warranty applies d Unless specifically authorized in a separate writing by Seller Seller makes no warranty with respect to and shall have no liability in connection with goods which are incorporated into othe
3. battery leakage Chapter 5 Troubleshooting Table 5 1 lists the symptoms possible causes and recommended solutions for common problems encountered with the Model 9515 If your symptom 1s not listed or if none of the solutions solves your problem please contact TSI Table 5 1 Troubleshooting the VELOCICALC Model 9515 Possible Causes Corrective Action No Display Dirty battery contacts Clean the battery contacts Velocity reading Fluctuating flow Reposition probe in fluctuates unstable less turbulent flow Instrument Error Fault in instrument Factory service required message appears on instrument WARNING Remove the probe from excessive temperature immediately excessive heat can damage the sensor Operating temperature limits can be found in Appendix A Specifications Appendix A Specifications Specifications are subject to change without notice Velocity Range 0 to 4000 ft min 0 to 20 m s Accuracy 5 of reading or 5 ft min 0 025 m s whichever is greater Resolution 1 ft min 0 01 m s Temperature Range 0 to 200 F 18 to 93 C Accuracy 0 5 F 0 3 C Resolution 0 1 F 0 1 C Instrument Temperature Range Operating Electronics 40 to 113 F 5 to 45 C Operating Probe 0 to 200 F 18 to 93 C Storage 4 to 140 F 20 to 60 C Instrument Operating Conditions Altitude up to 4000 meters Relative humidity up to 80 RH non condensing Pollutio
4. inoperative or defective instruments are as detrimental to TSI as they are to our customers our service policy is designed to give prompt attention to any problems If any malfunction is discovered please contact your nearest sales office or representative CONTENTS CHAPTER 1 UNPACKING AND PARTS IDENTIFICATION 1 CHAPTER 2 SETTING UP en dr 3 Supplying Power to the Model 9515 VELOCICALC Air Velocity MIG IOT tape cet e UE oi O PA 3 Installing the Batterles ocooccccccnccocnnccconnncnononononccnannnnnnns 3 Using The Telescoping Probe u 44400nenn nenne nnenne nenne nennen 3 Extending The Probe ccccccsscccssseeeseseceeseeseeeeseueeeneseeesages 3 Retracting The Probe 02220002000000000 000000 nnnnnn nennen nennen 3 CHAPTER 3 OPERATION ic 0000000 5 Keypad UC HONS einander 5 CHAPTER 4 MAINTENANCE cooccccococccconcoconnnnnnconnnaronnnnanennnnnnronnananenos 7 e A o no det en Erle T CASOS N TET TT EE EE E T E T O ea E A boicac cantas T CHAPTER 5 TROUBLESHOOTING cccccssseeeseeseeeseeneeeseeeeenees 9 APPENDIX A SPECIFICATIONG ccccccsseeeeseeseeeseeeeeeseeeneeseeees 11 ISO 9001 2000 111 Chapter 1 Unpacking and Parts Identification Carefully unpack the instrument and accessories from the shipping container Check the individual parts against the list of components below If anything 1s missing or damaged notify TSI immediately
5. n degree 1 in accordance with IEC 664 Transient over voltage category II External Meter Dimensions 3 3 in x 7 0 in X 1 8 in 8 4 cm x 17 8 cm x 4 4 cm Meter Weight Weight with batteries 0 6 lbs 0 27 kg Power Requirements Four AA size batteries included Temperature compensated over an air temperature range of 40 to 150 F 5 to 65 C The accuracy statement of 5 0 of reading or 5 ft min 0 025 m s whichever is greater begins at 30 ft min through 4000 ft min 0 15 m s through 20 m s Accuracy with instrument case at 77 F 25 C add uncertainty of 0 05 F F 0 03 C C for change in instrument temperature 11 Thank you for reading this data sheet For pricing or for further information please contact us at our UK Office using the details below sl La le UK Office Keison Products P O Box 2124 Chelmsford Essex CM1 3UP England Tel 44 0 1245 600560 Fax 44 0 1245 808399 Email sales keison co uk Please note Product designs and specifications are subject to change without notice The user is responsible for determining the suitability of this product
6. r products or equipment or which are modified by any person other than Seller The foregoing is IN LIEU OF all other warranties and is subject to the LIMITATIONS stated herein NO OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE OR MERCHANTABILITY IS MADE TO THE EXTENT PERMITTED BY LAW THE EXCLUSIVE REMEDY OF THE USER OR BUYER AND THE LIMIT OF SELLER S LIABILITY FOR ANY AND ALL LOSSES INJURIES OR DAMAGES CONCERNING THE GOODS INCLUDING CLAIMS BASED ON CONTRACT NEGLIGENCE TORT STRICT LIABILITY OR OTHERWISE SHALL BE THE RETURN OF GOODS TO SELLER AND THE REFUND OF THE PURCHASE PRICE OR AT THE OPTION OF SELLER THE REPAIR OR REPLACEMENT OF THE GOODS IN NO EVENT SHALL SELLER BE LIABLE FOR ANY SPECIAL CONSEQUENTIAL OR INCIDENTAL DAMAGES SELLER SHALL NOT BE RESPONSIBLE FOR INSTALLATION DISMANTLING OR REINSTALLATION COSTS OR CHARGES No Action regardless of form may be brought against Seller more than 12 months after a cause of action has accrued The goods returned under warranty to Seller s factory shall be at Buyer s risk of loss and will be returned if at all at Seller s risk of loss Buyer and all users are deemed to have accepted this LIMITATION OF WARRANTY AND LIABILITY which contains the complete and exclusive limited warranty of Seller This LIMITATION OF WARRANTY AND LIABILITY may not be amended modified or its terms waived except by writing signed by an Officer of Seller Service Policy Knowing that
7. tenna by pressing the probe tip Chapter 3 Operation Keypad Functions ON OFF Key Press to turn the Model 9515 on and off During the power up sequence the display will show the following Model Number Serial Number Software Revision and Last Date Calibrated ft min m s Key Pressing this key changes the display to read air velocity C F Key Pressing this key changes the display to read temperature Changing Units To change units first put the desired measurement air velocity or temperature on the display Then press and hold the left unlabelled key for five seconds Finally use the AW and ENTER key to select the units Chapter 4 Maintenance The Model 9515 requires very little maintenance to keep 1t performing well Recalibration To maintain a high degree of accuracy in your measurements we recommend that you return your Model 9515 to TSI for annual recalibration Please contact one of TSI s offices or your local distributor to make service arrangements and to receive a Return Material Authorization RMA number Cases If the instrument case or storage case needs cleaning wipe it off with a soft cloth and isopropyl alcohol or a mild detergent Never immerse the Model 9515 If the enclosure of the Model 9515 becomes broken it must be replaced immediately to prevent access to hazardous voltage Storage Remove the batteries when storing the unit for more than one month to prevent damage due to

Download Pdf Manuals

image

Related Search

Related Contents

  Model : BC-558  Haier 34F5D TV Receiver User Manual  VA 7036-HP3 - Equipment Services and Calibrations  ATSAMD10 Xplained Mini User Guide (USER  Xerox WorkCentre 7525V_FL multifunctional  Manual do utilizador - Instructions Manuals  ICs for Communications - Digi-Key  BISM-II Multipoint Firmware  Doc accu-chek safe-T  