1. 23 Decontamination and cleaning requirements 23 iii iv Contents Welch Allyn GS 777 Wall Transformer Symbol descriptions AC input power DC input power DC output power Separate Waste Electronic and Electrical Equipment WEEE from other disposables Prepare this product for reuse or separate collection as specified by the WEEE Directive 2002 96 EC or local law The product does not contain hazardous substances above threshold values defined in China Standard SJ T 11363 2006 The product is green and environmental and can be recycled after use Illuminated Power is present Not illuminated No power Type BF applied part 1 2 Symbol descriptions Welch Allyn GS 777 Wall Transformer Safety All users of the device must read and understand all safety information presented in this manual before using or repairing the device United States federal law restricts this device to sale distribution or use by or on the order of a licensed medical practitioner General warnings and cautions WARNING Read and understand the instructions before using this product Failure to understand the operating requirements for this product can result in injury to you or the patient and can damage the product WARNING Explosion hazard Do not operate this product in the presence of
2. 6 Returning products 6 Controls indicators and connectors 9 Troubleshooting 11 Symptoms and solutions 13 Disassembly and repair 15 Required tools and equipment 15 Remove rear housing handles circuit board cradle wire harnesses and cradles 15 Functional verification and calibration 19 Functional verification tests 19 Verify functionality 19 Field replaceable units 21 GS 777 Wall Transformer 21 Appendices
3. www welchallyn com Regulatory Affairs Representative Welch Allyn Limited Navan Business Park Dublin Road Navan County Meath Republic of Ireland Contents Symbol descriptions 1 Safety 3 General warnings and cautions 3 General safety considerations 4 Electrostatic discharge ESD 4 Overview 5 Purpose and scope 5 Technical support services 5 Service options 5 Repairs
4. A complete return shipping address A contact name and phone number Any special shipping instructions A purchase order number or credit card number if the product is not covered by a warranty A full description of the problem or service request 1 Contact Welch Allyn and request a Return Material Authorization number 2 Ship the device to Welch Allyn observing these packing guidelines a Put the system and a packing list into the original shipping carton with the original packing materials or into another appropriate shipping carton 6 Overview Welch Allyn GS 777 Wall Transformer b Write the Welch Allyn RMA number with the Welch Allyn address on the outside of the shipping carton Note To ensure safe receipt of your system by the service center and to expedite processing and return of the system to you thoroughly clean all residues from the device before you ship it to Welch Allyn For decontamination and cleaning requirements see Decontamination and cleaning in the appendices If a returned device is found to be contaminated with bodily fluids it will be returned at the owner s expense United States federal regulations prohibit the processing of any device contaminated with blood borne pathogens Welch Allyn thoroughly cleans all returned systems on receipt but any system that cannot be adequately cleaned cannot be repaired Service manual Overview 7 8 Overview Welch Allyn GS 77
5. 5W ADAPTER PLUG UK 713265 5W ADAPTER PLUG EURO 713266 5W ADAPTER PLUG AUS 715162 5W ADAPTER PLUG CHINA 715163 5W ADAPTER PLUG S AFRICA 22 Field replaceable units Welch Allyn GS 777 Wall Transformer Appendices Decontamination and cleaning requirements As a general safety precaution the device must undergo decontamination before being returned to Welch Allyn for service repair inspection or disposal Note Contaminated items must not be returned without prior written agreement Note Decontaminate the device according to your facility s procedures and local regulations Cleaning is an essential prerequisite for effective disinfection or decontamination Note The following guidelines apply to the device only For peripheral items follow the cleaning instructions in the directions for use that accompany these accessories WARNING Before you clean the GS 777 Wall Transformer unplug it from the wall socket WARNING Electric shock hazard DO NOT autoclave the GS 777 Wall Transformer or accessories WARNING Liquids can damage electronics inside the GS 777 Wall Transformer Prevent liquids from spilling on or dripping into the GS 777 Wall Transformer If liquids are spilled on or drip into the GS 777 Wall Transformer 1 Disconnect the power plug 2 Remove the GS 777 Wall Transformer from the wall 3 Dry off excess liquid from the GS 777 Wall Transformer 4 Mount the GS 777 Wall Transformer on the wa
6. can help you diagnose and fix a problem They do not replace basic troubleshooting skills You must still trace the source of the problem to the board or module level to decide the best course of action Welch Allyn does not support component level repair to the board or module For available replacement parts see Field Replaceable Units WARNING Do not perform troubleshooting on a device that is emitting smoke or exhibits other signs of excessive overheating Disconnect the device from AC power and call Welch Allyn Technical Support immediately 11 Caution Replace parts components or accessories only with parts supplied or approved by Welch Allyn The use of any other parts can lead to inferior performance and will void the product warranty 12 Troubleshooting Welch Allyn GS 777 Wall Transformer Symptoms and solutions Handles Symptom Possible cause Suggested action The lamp does not illuminate There is no lamp in the handle head Install a lamp in the handle head The lamp is burned out Install a new lamp The other handle is off the cradle Place the other handle in the cradle The system is not powered up Power up the system The PCBA is defective Replace the PCBA The handle assembly is defective Replace the handle assembly The lamp is too dim The rheostat setting is too low Increase the rheostat setting The PCBA is defective Replace the PCBA The handle assembly is defective Replace the h
7. use accessories according to your facility s standards and according to the manufacturer s recommendations and instructions Always follow the manufacturer s directions for use Welch Allyn recommends that only Welch Allyn service personnel or an authorized repair center perform warranty service Performing unauthorized service on a device that is within warranty may void the warranty Electrostatic discharge ESD Caution Electrostatic discharge ESD can damage or destroy electronic components Handle static sensitive components only at static safe workstation Caution Assume that all electrical and electronic components of the device are static sensitive Electrostatic discharge is a sudden current flowing from a charged object to another object or to ground Electrostatic charges can accumulate on common items such as foam drinking cups cellophane tape synthetic clothing untreated foam packaging material and untreated plastic bags and work folders to name only a few Electronic components and assemblies if not properly protected against ESD can be permanently damaged or destroyed when near or in contact with electrostatically charged objects When you handle components or assemblies that are not in protective bags and you are not sure whether they are static sensitive assume that they are static sensitive and handle them accordingly Perform all service procedures in a static protected environment Always use tech
8. 7 Wall Transformer Controls indicators and connectors Front view No Feature Description 1 Physical assessment instruments Handles and handle cradles Handles will accept any 3 5V Welch Allyn instrument head The handle cradles support using one handle at a time A handle turns on automatically when you remove it from a cradle and turns off when you return it 2 Rheostat Located on each handle Turn clockwise to increase light output turn counterclockwise to decrease light output 3 LED indicator Indicates power is present 4 USB power cable Twin USB power cable 5 5W power supply with LED indicator 5W platform power supply Indicates power is present 6 5W adapter plug Region specific 5W adapter plug 9 Back view No Feature Description 1 Host USB mini power in 5V USB type mini Provides power to the GS 777 Wall Transformer 2 Host USB power out 5V USB type A Provides power to other supported Welch Allyn devices 10 Controls indicators and connectors Welch Allyn GS 777 Wall Transformer Troubleshooting This section provides a process diagram to help you troubleshoot the device Follow it first and then refer to the accompanying tables This section provides the following tables to help you troubleshoot the device Symptoms and solutions These tables list symptoms you might observe list possible causes and suggest actions that might eliminate the problem These tables
9. Welch Allyn GS 777 Wall Transformer Service manual 2012 Welch Allyn All rights are reserved To support the intended use of the product described in this publication the purchaser of the product is permitted to copy this publication for internal distribution only from the media provided by Welch Allyn No other use reproduction or distribution of this publication or any part of it is permitted without written permission from Welch Allyn Welch Allyn assumes no responsibility for any injury to anyone or for any illegal or improper use of the product that may result from failure to use this product in accordance with the instructions cautions warnings or statement of intended use published in this manual Welch Allyn is a registered trademark of Welch Allyn For information about any Welch Allyn product call Welch Allyn Technical Support USA Canada European Call Center Germany Japan Malaysia Singapore Spain United Kingdom 1 800 535 6663 1 315 685 4560 1 800 561 8797 353 46 90 67790 49 695 098 5132 81 42 703 6084 603 7875 3341 65 6419 8100 34 917 499 357 44 207 365 6780 Australia China France Italy Latin America Netherlands South Africa Sweden 61 2 9638 3000 86 21 6327 9631 33 155 69 58 49 39 026 968 2425 1 305 669 9003 31 202 061 360 27 11 777 7555 46 85 853 6551 Material Number 718860 Ver A Welch Allyn Inc 4341 State Street Road Skaneateles Falls NY 13153 0220 USA
10. andle assembly The lamp is too bright The rheostat setting is too high Decrease the rheostat setting The PCBA is defective Replace the PCBA The handle assembly is defective Replace the handle assembly The lamp brightness does not adjust The PCBA is defective Replace the PCBA The handle assembly is defective Replace the handle assembly The handle becomes very hot to the touch The lamp has been on for an extended period of time Return the handle to the cradle Note The GS 777 Wall Transformer will accommodate instrument heads of the Welch Allyn approved Halogen and LED type bulbs without any manual adjustment For information about instrument heads follow the instructions provided in their directions for use Service manual Troubleshooting 13 14 Troubleshooting Welch Allyn GS 777 Wall Transformer Disassembly and repair These procedures provide instructions for system disassembly and board removal Except where otherwise noted the assembly procedure is the reverse of the disassembly procedure Each procedure may include the following Reassembly notes This contains information specific to reassembly not addressed in the disassembly instructions WARNING Electrical shock hazard Disconnect power before opening the device Caution Before disassembling the device disconnect the USB power cord and any attached accessories Caution Perform all repair procedures at a static protected station C
11. aution When the system case is opened regard all parts as extremely fragile Execute all procedure steps with care and precision Caution Observe screw torque specifications especially with screws that secure directly into plastic standoffs Caution To avoid mismatching screws and holes keep the screws for each piece with that piece as you remove modules and circuit assemblies Required tools and equipment 2 Phillips bit Screw driver calibrated for 6 0 in lb 1 0 in lb 10 Torx bit Torque driver calibrated for 7 5 in lb 0 5 in lb Needle nose pliers Remove rear housing handles circuit board cradle wire harnesses and cradles Remove the rear housing Disconnect the USB power cord and any attached accessories a Remove the device from the wall 15 b Disconnect the USB cable c Remove the rear housing by removing the four large Phillips screws d Lift and remove the rear housing Remove the handles e Disconnect the handle connector wires from the PCBA 16 Disassembly and repair Welch Allyn GS 777 Wall Transformer f Lift and remove the handle cables from the front handle housing Reassembly note When reconnecting the handle connection wires to the handle PCBA the connecting wires must be facing up and away from the PCBA Remove the circuit board g Disconnect the two IR wire connectors from the Circuit board h Remove the three torx screws i Lift an
12. d remove the Circuit board Reassembly note When reconnecting the IR wire connectors to the handle PCBA the connecting wires must be facing down and toward the cradle assemblies Service manual Disassembly and repair 17 Remove the handle cradle and optical assemblies j On the rear of the assembly disconnect both IR wires from the optical sensors k Push in the snap tabs and then remove the cradle assembly by pushing outward Reassembly note For ease of assembly connect the IR wire assemblies to the optical sensors before attaching the handle cradle to the handle assembly housing Attach the connector with the black and white wires to the optical detector indicated by the letter B molded into the cradle plastic Attach the connector with the red and white wires to the optical emitter The wires should face inward once the handle cradle is assembled l Snap the handle cradle assembly into the front housing Make sure that the cradle assembly tab and the beveled edge are at the top of the housing 18 Disassembly and repair Welch Allyn GS 777 Wall Transformer Functional verification and calibration Functional verification tests The functional verification tests help to confirm the proper operation of the device and its options These tests support the requirements of routine preventive maintenance It is not necessary to disassemble the device to perform these tests The tests may also be useful as a diagnostic to
13. flammable anesthetics or other flammable substances in combination with air oxygen enriched environments or nitrous oxide WARNING Electric shock hazard Do not simultaneously touch the patient and the center metal contact of the handle WARNING Do not modify this equipment Any modification of this equipment can lead to patient injury Any modification of this equipment voids the product warranty WARNING Welch Allyn is not responsible for the integrity of any mounting installation Welch Allyn recommends that customers contact their Biomedical Engineering Department or maintenance service to ensure professional installation for safety and reliability of any mounting accessory Caution As a precaution avoid using this product in close proximity to other equipment The product complies with current required standards for electromagnetic interference and should not present problems to other equipment or be affected by other devices Caution Only authorized Welch Allyn Service Centers can perform service on this product Caution To make sure that the transformer can be unplugged from the AC power source never block access to the wall socket Caution Rx only for professional use 3 Caution Do not autoclave the system Autoclave accessories only if the manufacturer s instructions clearly approve it General safety considerations To ensure patient safety use only accessories recommended or supplied by Welch Allyn Always
14. ll 5 Verify that the GS 777 Wall Transformer functions normally before using it Clean the GS 777 Wall Transformer on a routine basis according to your facilities protocols and standards or local regulations To clean the GS 777 Wall Transformer excluding the instrument heads use any of the following A clean cloth slightly dampened with 70 percent isopropyl alcohol or 10 percent chlorine bleach solution Wipe dry with a clean cloth Sani Cloth Plus CaviWipes see caution below 23 Caution Do not use CaviWipes to clean the blue handle cradles This cleaning agent produces bubbles and liquid during the cleaning process that can enter openings in the cradles and limit handle performance for as long as 30 minutes after cleaning To clean the instrument heads follow the instructions provided in their directions for use 24 Appendices Welch Allyn GS 777 Wall Transformer
15. low the instructions exactly as presented in this manual Failure to do so could damage the device invalidate the product warranty and lead to serious personal injury Caution No component level repair of circuit boards and subassemblies is supported Use only the repair procedures described in this manual This manual applies only to this device For servicing of any other device see the service manual for the specific device Service work not described in this manual must be performed by qualified service personnel at the factory or at an authorized Welch Allyn service center Technical support services Welch Allyn offers the following technical support services Telephone support Replacement service parts Product service For information on any of these services call the Welch Allyn Service Center nearest you Service options Warranty service All repairs on products under warranty must be performed or approved by Welch Allyn Refer all warranty service to Welch Allyn Product Service or another authorized Welch Allyn Service Center Obtain a Return Material Authorization RMA number for all returns to Welch Allyn Product Service 5 Caution Unauthorized repairs will void the product warranty Non warranty service Welch Allyn product service and authorized service centers support non warranty repairs Contact any Welch Allyn regional service center for pricing and service options Welch Allyn offer
16. niques and equipment designed to protect personnel and equipment from electrostatic discharge Remove static sensitive components and assemblies from their static shielding bags only at static safe workstations a properly grounded table and grounded floor mat and only when you are wearing a grounded wrist strap with a resistor of at least 1 megohm in series or other grounding device Use only grounded tools when inserting adjusting or removing static sensitive components and assemblies Remove or insert static sensitive components and assemblies only with device power turned off Insert and seal static sensitive components and assemblies into their original static shielding bags before removing them from static protected areas Always test your ground strap bench mat conductive work surface and ground cord before removing components and assemblies from their protective bags and before beginning any disassembly or assembly procedures 4 Safety Welch Allyn GS 777 Wall Transformer Overview Purpose and scope This service manual is a reference for corrective service procedures for the Welch Allyn GS 777 Wall Transformer It is intended for use only by trained and qualified service personnel Corrective service is supported to the level of field replaceable units These include circuit board assemblies and some subassemblies case parts and other parts WARNING When performing a service procedure fol
17. ol to help isolate a malfunction Verify functionality To verify functionality 1 Connect power to the device and ensure the power LED indicator is illuminated 2 Attach a working instrument head to each handle assembly 3 Remove a handle from the cradle and verify illumination 4 Test the handle rheostat to ensure illumination adjusts from minimum to maximum output 5 Return the handle to the cradle 6 Repeat for the remaining handle The instrument heads should automatically turn off when returned to the cradle 19 20 Functional verification and calibration Welch Allyn GS 777 Wall Transformer Field replaceable units This listing includes only field replaceable service parts Product accessories including 3 5V instrument heads and other consumable items are listed separately in the accessories list in the device s directions for use which is available from Welch Allyn Customer Service GS 777 Wall Transformer Kit part numbers No part numbers Item 1 104299 SK KIT HANDLE ASSEMBLY 2 408514 PCBA 777 WALL TRANSFORMER 3 105062 SK ASSY CRADLE 2PC BLUE 4 104992 SK 777 FRONT W LIGHT PIPE 5 104993 SK 777 TWIN REAR HSG Not Illustrated 408781 777 WALL MOUNTING KIT Not Illustrated 104281 SK IR CONNECTOR amp WIRE ASSY 21 No part numbers Item 1 104713 TWIN USB POWER CABLE 2 104996 SK 5W PLATFORM POWER SUPPLY 3 713263 5W ADAPTER PLUG US 713264
18. s modular repair parts for sale to support non warranty service This service must be performed only by qualified end user biomedical clinical engineers using this service manual Repairs A Welch Allyn Service Center must perform all repairs on products under warranty Caution Unauthorized repairs will void the product warranty Qualified service personnel or a Welch Allyn Service Center should repair products out of warranty If you are advised to return a product to Welch Allyn for repair or routine maintenance schedule the repair with the service center nearest you Welch Allyn Technical Support If you have a problem with the device that you cannot resolve call the Welch Allyn Technical Support Center nearest you for assistance A representative will assist you in troubleshooting the problem and will make every effort to solve the problem over the phone avoiding a potential unnecessary return If your product requires warranty or non warranty repair service a Welch Allyn Technical Support representative will record all necessary information to issue an RMA number The support representative will provide you with the address of the Welch Allyn Service Center to send your device to Technical support is available during local business hours Returning products Note Welch Allyn does not accept returned products without an RMA When returning a product to Welch Allyn for service please include the following information
Download Pdf Manuals
Related Search
Related Contents
「安心安全メール」「校区情報」配信登録方法 - NGX Technologies Playseats Evolution Alcantara Guía del usuario de la pantalla con rotulador interactivo SMART Whynter RPD-621EW Use and Care Manual 1 - TS Industrie Therma-Stor Products Group TS-261B User's Manual Peros USB-HUB96 DMR132 Manual(¿µ).QUX Copyright © All rights reserved.