Home

KT-400 Installation Manual DN2003.book

image

Contents

1. 5 Trouble and guia aS 5 Visual Status Indicators LEDS dod edad 5 SPI EXPANSION 5 SV SISIMTPANCHILCCIUNG TL 9 Heartbeat LED PANGS sut odio ot vues e vM 12 Technical ao 13 mese elerisque 14 KT 400 Ethernet Four Door Controller Models Expansion Modules Models Related Documentation and Miscellaneous Rte PS 14 Models IMfOFMalOM ERR REO 16 Installing the KT 400 Ethernet Four Door Controller 17 Preparing to Install the KT 400 Ethernet Four Door Controller 17 tert Lm M M 17 eco M EE ND TEN ET 17 DOOMEOCKING DEVICES T a 17 PIOOKING UO INPUTS 18 and KEV HOUSE ev isn Gel eee 18 Relay Controlled Outputs 19 nudae cU
2. EM 39 Bate tn PT 39 294 Compliance NOLDGG 39 UE T1076 NOCE YO Rao eode t Leda e eis 39 Heer opc c nme 40 DN2003 1201 v01 11 IPTE TT ten een ee Ree a TA Maa QA iv DN2003 1201 v01 11 TYCO INTERNATIONAL LTD END USER LICENSE AGREEMENT FOR KANTECH Software Provided With or Without Products or Components IMPORTANT READ CAREFULLY KANTECH Software purchased with or without Products and Components is copyrighted and is purchased under the following license terms This End User License Agreement EULA is a legal agreement between You the company individual or entity who acquired the Software and any related Hardware and KANTECH the manufacturer of the integrated security systems and the developer of the software and any related products or components HARDWARE which You acquired If the KANTECH software product SOFTWARE PRODUCT or SOFTWARE is intended to be accompanied by HARDWARE and is NOT accompanied by new HARDWARE You may not use copy or install the SOFTWARE PRODUCT The SOFTWARE PRODUCT includes computer software and may include associated media printed materials and online
3. NOLLO3NNOO m JNO 145 19 eure 1 9L dNI OONW L9 308 5 1VN 31X3 sduy Z QA 21 Q31V1093MWy 007 13 OL E T 25 DN2003 1202 v01 11 Figure 12 Expansion Modules Cabinets for North America and European Union KT MOD CABEU for European Union with Optional Expansion Modules 4 max and Optional Power Equipment KT MOD CAB for North America with Optional Expansion Modules 6 max SEALED RECHARGEABLE BATTERY 26 DN2003 1202 v01 11 KT 400 Ethernet Four Door Controller Installation Manual Troubleshooting Table 3 Reset Types and Descriptions Soft Reset When JP2 and JP3 are ON the controller will reset on a power up b pushbutton or c EntraPass software Manual operator soft reset e controller s memory definitions and parameters are verified and kept intact if still valid 465 With a corporate gateway the internal event buffer is maintained if still valid With a global gateway the internal event buffer is cleared IP address is kept if valid Controller generates the appropriate message Power ON Soft Reset b Manual Pushbutton Soft Reset c Operator Soft Reset Hard Reset When JP2 is OFF and JP3 is ON All controller s memory is settled to default values Internal event buffer is cleared 3 short pulses
4. 12V BATTERY 4 5 PART amp KT BATT 12 Note DO NOT CONNECT mum RECEPTACLE CONTROLLED ee BY SWITCH d PEM CABINET IF INTERNAL POWER USED 4 set to INT see Note 16 CONNECT 1 OHM RESISTOR CLASS 2 WIRE GROUND IF NOT USED 120 VAC 80 Hz IN DN2003 1202 v01 11 37 Figure 15 KT 400 EU Inner Door Sticker Diagram European Union Note regarding output voltage ratings Auxiliary Power 11 2 to 13 75 VDC 12 VDC Readers 11 2 to 13 75 VDC 5 VDC Readers 5 VDC LOW SPEED R 3 232 1200 115200 BAUD DEVICE amp PIN EXPANSION PORT FOR EXPANSION MODULES j E E 5 P325KP READER WITH TIRE INTEGRATED KEYPAD SEE NOTE BLUE RED S00 i dr ia RS 485 x m m vu FISH ISI 31 CONTROLLERS BLUE 59 THs 1094 indo WHITE m rise 8 230 100 16 5 OUT TRANSFORMER PART TRE100 240V NEUTRAL EARTHGROUND E 240 VAC av 50 200 o Oia LIVE 38 250VAC Time lag VDE approved Must meet ENB0127 1 2 3 DN2003 1202 v01 11 T m 5 m SO sm SWITCH ETHERNET 1 and 2 TO RX See TX
5. Router O Public IP Address 0 Domain name Port Forwarding Checklist Note f you are using more than one KT 400 at the same remote site you must use a unique port number for each KT 400 KT 400 Ports 18803 UDP and LJ 18810 UDP or Note No port forwarded to the KT 400 if used in TCP 34 DN2003 1202 v01 11 400 Ethernet Four Door Controller Installation Manual Installation Checklist To the Installer If you are familiar with the installation you can use the checklist with the L symbol Installing the KT 400 Ethernet Four Door Controller Preparing to install the KT 400 Ethernet Four Door Controller Required to install KT 400 Ethernet Four Door Controller Physical Installation Check for ideal indoor location 0 Stay away from electrical or communication devices Earth Grounding L AWG 18 grounding wire to EGND Door Locking Devices Connect the door locked device to and LK1 and LK2 and LK3 or and LK4 L When jumper JP4 is on INT internal the maximum current draw is 1 Amp at 11 2 to 13 75 VDC or When jumper JP4 is on EXT external the maximum current draw is 1 0 2 0 3 0 or 4 0 Amps at 12 to 28 VDC depending on power source used Check for local magnetic lock regulations Hooking Up Inputs Connect devices to inputs 1 to 16 0 Resistors for all inputs 5 6K ohm if necessary Connect readers and keypads Auxiliary Outputs Conn
6. Configuring 400 Ethernet Four Door Controller with KT Finder continued za KT Finder Wizard Language About KANTECH KT Finder Boot loader and firmware version MAC address EntraPass IP Address 1 Domain name Domain name resolution Obtain an IP address automatically IP address Subnet Mask Gateway Router Protocol Port 7 Put jumpers on JP2 and Version 5 01 09 KT 400 0 27 1 10 01 00 50 F9 50 06 014 EntraPass Gateway 10 38 192 99 Test DNS Ethernet configuration 10 38 192 158 255 255 202 0 10 38 195 254 10 50 58 5 UDP 18810 8 Verify your Network Configuration Information Sheet e Enter the EntraPass IP address or the Domain name of the EntraPass Gateway This information must be the same as entered in EntraPass workstation for Devices gt Site Select Obtain an IP address automatically or Use the following IP address This information must be the same as entered in EntraPass workstation for Devices Site 9 Select a Protocol UDP or TCP 10 Change the Port number if required not applicable in TCP Note The port number should only be changed when you have more than one KT 400 at the same remote site 11 Click OK 12 Repeat the procedure for each KT 400 at this site 32 DN2003 1202 v01 11 KT 400 Ethernet Four Door Controller Installation Manual KT 400 Ethernet Four Door Controller Network Configuration Information S
7. IP address is kept if valid Controller generates the message Controller Hard Reset Internal RTC Real Time Clock and clock are settled to the default time and date values January 1st 2005 00 00 00 Saturday Forced Default Static When JP2 is ON and is OFF 3 long pulses e Same as Soft condition except IP address is forced to the default static IP 192 168 1 2 Factory Default DHCP When JP2 and JP3 are OFF All controller s memory is settled to default values Internal event buffer is cleared Contingous Controller generates the message Controller long pulses Factory Default Reset The Ethernet port reverts to DHCP configuration and waits for an IP address from the local DHCP server Internal RTC and clock are settled to the default time and date values January 1st 2005 00 00 00 Saturday DN2003 1202 01 11 27 Table 4 AC and Power LED Status Indicators AC Power LED DC Power LED Status Indicators e The AC power is present The DC power level is sufficient for all DC operations such as the readers outputs and the 12V AUX e The AC power is below minimum requirements and e the 12V rechargeable backup battery is either not connected or e its voltage is below minimum requirements ON TA s running on the 12V rechargeable backup battery _ Default Initialization The KT 400 default initializa
8. 400 Cabinet Models for North America and European Union KT 400 Cabinet with Optional Expansion Modules 2 max and Optional Battery LCD SEALED RECHARGEABLE BATTERY c KT 400 EU Cabinet for European Union exe eere ec oo eae eee cee eee eee eee ees amp DN2003 1202 v01 11 KT 400 Ethernet Four Door Controller Installation Manual System Architecture The KT 400 Ethernet Four Door Controller can be used through various site applications with EntraPass Special Corporate and Global Editions Applications with EntraPass Special and Corporate Editions with Multi site Gateway e Over the internet See Figure 4 e Over RS 485 with a USB 485 See Figure 5 Application with EntraPass Global Edition and a Global Gateway e Over RS 485 with a VC 485 See Figure 6 Application with EntraPass Global Edition and a KT NCC e Over the Internet with KT NCC See Figure 7 Application with EntraPass Special Corporate and Global Editions e Over RS 232 straight from EntraPass RS 232 COM port See Figure 8 Figure 4 Over the Internet with EntraPass Special and Corporate Editions with Multi site Gateway KT 100 EntraPass Special Edition and upto 31 Multi site Gateway RS 485 KT 400 Master KT 400 Master Controller m Controller LAN WAN 10 100Base T 128 bit encrypted secure connection KT 400 Master Controller lt gt Router ADSL Cable Mod
9. DN1316 EntraPass Global Edition Reference Manual English version DN1474 EntraPass Special Edition Reference Manual French version DN1435 EntraPass Corporate Edition Reference Manual French version DN1289 EntraPass Global Edition Reference Manual French version DN1796 Networking Basics Application Note English version Dimensions Drawings DN1791 KT CAB3000LDR 71 cm 28 in Cabinet Dimensions Drawing DN1793 KT CAB4000LDR 107 cm 42 in Cabinet Dimensions Drawing DN1846 KT 400 PCB Dimensions Drawing DN1848 KT 400 CAB Dimensions Drawing UL Listed DN1850 KT 400 CABEU Dimensions Drawing CE Compliant DN1851 KT MP400 Mounting Plate Dimensions Drawing DN1852 KT MP500 Mounting Plate Dimensions Drawing Miscellaneous Items CBLK 10 Cable kit RS 232 cable 30 m 100 ft with RJ 12 connectors for PC to master KT 400 740 1023 DB9F to RJ 12 adaptor and 740 1041 DB9M to DB25F adaptor USB 485 USB 485 interface USB cable 0 9 3 ft and USB drivers on CD ROM VC 485 VC 485 interface RS 232 cable 3 m 10 ft with RJ 12 connectors 740 1012 DB25F to RJ 12 adaptor 740 1022 DB9F to RJ 12 adaptor and 740 1033 DB25M to RJ 12 adaptor KT 3LED PLATE Three color LED alarm indicator mounted on single plate KT ACPW LED AC power LED indicator DN2003 1202 v01 11 15 Models Information e 400 Cabinet with one KT 400 for North America up to two expansion modules be installed in the cabinet
10. INPUT DOOR 3 1 4 r READER 3 READER 0008 4 34 DOOR REX 21 SPI oooooo TELL DOOR gu er 1 Zone Imputs 212 REX 215 216 5 DO 11 GND OUTI OJT LED Buz tewv zwv 10 Di OUTi OUTS LED BUZ egeret m m m m m m mm m u mmm mmm mmm mmm mm m mm mm mm ojooojoopojjoojeoojpojoooj oojjj 01 0 010 01 01010 0100 EEIEDEDODBDBOEDOBDOREJSERSEBEBEBEEBIJIEBBBBEREBD REX 23 4 DOOR C z 78 DO Dl GHD OJTI DUTE LED WWE 12 D GAD OUTS LED RUZ READER 1 l L_______ READER poor En Reader Interfaces P w 2 4B5 85 485 FREE 3 RELAY 4 3 4 54 5 4 NC Mi HC HO NC AO Relays 4 NI H3MOd I ABL MOO T1X4 t SLAG M901 HOLS H3MOd Xv OY DN2003 1202 v01 11 KT 400 Ethernet Four Door Controller Installation Manual Figure 2 KT 400 Ethernet Four Door Controller Inputs and Outputs View ATH 20 SLET RT ILA ASL Geo qunm NAJOT rs S IE SER CAR E FI DN2003 1202 v01 11 Figure 3
11. KT 400 Ethernet Four Door Controller Installation Manual Configuring the KT 400 Ethernet Four Door Controller with the KT Finder The KT Finder is an application used to configure the KT 400 over the local area network LAN or the wide area network WAN It doesn t require any installation Important The KT Finder application is e located in C Program Files Kantech Server_xE Bin onthe EntraPass DVD ROM e available as a free download from http www kantech com 1 Quit all EntraPass applications 2 Make sure the KT 400 is in Factory Default DHCP mode See Table 3 on page 28 3 Start the KT Finder Note f you try to run the KT Finder while running EntraPass you will get an error message similar to this or Use another computer to perform the task 59 Please quit EntraPass before running the KT Finder OK 4 Select KT 400 from the Device menu 5 Enter the MAC address of the KT 400 then click on Connect za KT Finder Wizard Language About The KT Finder will assist you in the confiquration steps involved to operate the IP device To locate the IP device within the LAN enter the address then click Connect the IP device is at a remote location like a you must also provide the public IP address Device 400 address 00 50 F3 50 0B 0A Connect Public IP address 6 When the KT 400 is found the configuration page displays DN2003 1202 v01 11 31
12. gt 566 494 cem ra Em CNW Cem CEN Tee SPI QUT CONNECTION TO OUTPUT MODULES ONLY KT MOD RELB and KT MOD OUT18 0601 REV A0 KT MOD OUT16 KT 400 Expansion Module 16 Output with SPI Cable BLUE SE gE 16 SPI IN CONNECTIOM FROM KT 400 or PREVIOUS OUTPUT MODULE or SPI EXPANSION PORT FROM 1st KT MOD INP16 REGULATED POWER SUPPLT 12 VDC 2 Amps OUTPUT DEVICE OPTIONAL EXTERNAL POS 5to 24 VDC HIGH POWER SOURCE 12 VDC up to 750 mA up to 750 5 to 24 VDC ABSOLUTE TOTAL OUTPUTS INTERNAL OR EXTERNAL SUPPLY 24 DN2003 1202 v01 11 KT 400 Ethernet Four Door Controller Installation Manual Figure 11 Example of KT 400 Ethernet Four Door Controller Interconnection with Expansion Modules TWNUALNI 2 S 064 dn oe 32218 3910 N3MOd 2Q 015 TVNN31X3 1 1 Pe rs 391A30 HONOIDION 3 Andino OL NOLL23NNOO ___________ 1X3 NI 195 Ldr 1 813u COW LY 91 1NO GOW LY son JIBNOS WNYALXS 50193139 NOLLOW SOA ZL sdwyZ OGA Zi O31v 11934 1NI Saf Jedunr non 6500
13. BROWN BROWN a Io LA Relay Controlled Outputs The KT 400 provides four relay outputs RELAY1 to RELAY4 3 Amps 30 VAC VDC The KT 400 can be expanded up to 256 controlled outputs when using expansion modules e The KT MOD OUT16 module provides 16 outputs at a maximum of 750 mA per output he KT MOD REL8 module provides 8 relay outputs at a maximum of 3 Amps per relay G8p Note Since the KT 400 maximum output current draw on the SPI expansion port is 500 mA when the 12V AUX terminals are not used an external power supply of 12 VDC 2 Amps is required when adding expansion modules to the same KT 400 See SPI Expansion Port on page 23 for additional details concerning the external power supply requirement for expansion modules 134 6 C Auxiliary Outputs Connect auxiliary outputs to readers and local warning devices Auxiliary outputs are used for visual and audible signal They can be activated according to input conditions or events and local alarms Auxiliary outputs READER DOOR 1 to 4 LED provide visual feedback of access operation and auxiliary outputs READER DOOR 1 to 4 BUZ can activate audible warning devices such as T REX or reader buzzer to signal door alarms L4 rev Tamper Protection install tamper switch on cabinet A tamper switch must be installed on the unit to detect unauthorized cabinet opening
14. card RESET UP E up ate PWR 12V BATTERY 7 Ah KANTECH PART KT BATT 12 DOOR LOCKING DEVICE Imm 12 750 mA FER OR 2 0 AMPS TOTAL JP4 MUST BE SET TO INT CONNECT 1K OHM RESISTOR IF NOT USED 400 Ethernet Four Door Controller Installation Manual Appendix A Compliance Specifications UL To comply with UL listings the following requirements must be met Use of a UL listed computer Use of UL listed readers Wiegand 26 and 34 bits mag stripe 26 and 34 bits XSF 39 bits have been tested and found to comply Use of a UL recognized tamper switch on every housing cabinet for the KT 400 Ethernet Four Door Controller Do not use the SmartLink option Do not use a 230 VAC transformer not UL listed Use only UL listed cables Use only UL listed adaptors Use only a UL listed transformer Hammond BF2F or BF2G such as Kantech part number TR1675 or TR 2475 available through Kantech distributors or dealers please refer to the Technical Support contact information on page 2 to obtain the specific transformer The KT 400 EU has not been validated as a UL Listed system The KT CAB3000LDR and KT CAB4000LDR have been evaluated by UL as alternate enclosures Note All circuits are power limited UL 294 Compliance Notice IP Connectivity Only for supplementary use when planning to install the KT 400 Ethernet Four Door Controller with a UL 294 access control system Us
15. e 400 KT 400 with parts e 400 Accessory kit e 400 Cabinet only for North America e KT 400 EU Cabinet with KT 400 transformer power supply and fuse terminal block for European Union e KT 400 CABEU Cabinet only for European Union Table 2 Bills of Material Models Item Description KT 400 PCB KT 400 ACC KT 400 CAB KT 400 EU KT 400 Note 2 Notes 1 amp 4 Notes 1 2 CABEU 3 4 amp 5 Notes 1 amp 4 mew TT 7 dI T 4 JE Fn cts 5 ___ ___ _ gt _ mew Fuse terminal block terminal block 230 100 16 5 VAC OUT Transformer Inner door sticker for North 1 1 America DN2023 Figure 14 Inner door sticker for European Union DN2024 1 1 Figure 15 Installation Manual DN2022 1 1 1 French Installation Manual DN2003 1 1 1 English Note 1 The KT 400 400 KT 400 EU and KT 400 CABEU models also include the KT LOCK Note 2 The KT 400 400 and KT 400 EU models also include screws and locknuts Note 3 The KT 400 EU model also includes additional screws and cables Note 4 Cabinet wall mounting requires four 4 screws We recommend stainless steel Phillips tapping screws M4 2 x 32mm 8 x 1 25 Spaenaur ST 631P or equivalent Drywall mounting must also use four 4 plastic
16. or electronic documentation Any software provided along with the SOFTWARE PRODUCT that is associated with a separate end user license agreement is licensed to You under the terms of that license agreement By installing copying downloading storing accessing or otherwise using the SOFTWARE PRODUCT You agree unconditionally to be bound by the terms of this EULA even if this EULA is deemed to be a modification of any previous arrangement or contract If You do not agree to the terms of this EULA KANTECH is unwilling to license the SOFTWARE PRODUCT to You and You have no right to use it SOFTWARE PRODUCT LICENSE a as 2 The SOFTWARE PRODUCT protected by copyright laws and international copyright treaties as well as other intellectual property laws and treaties The SOFTWARE PRODUCT is licensed not sold GRANT OF LICENSE This EULA grants You the following rights Software Installation and Use For each license You acquire You may have only one copy of the SOFTWARE PRODUCT installed Storage Network Use The SOFTWARE PRODUCT may not be installed accessed displayed run shared or used concurrently on or from different computers including a workstation terminal or other digital electronic device Device In other words if You have sev eral workstations You will have to acquire a license for each workstation where the SOFTWARE will be used Backup Copy You may make back up copies of the SOFTWARE PRODUCT b
17. x 13 97 5 5in x 4 06cm 1 6in Reader types Wiegand proximity ABA Clock and Data bar code magnetic integrated keypad smartcard and others Reader power output 12 VDC and 5 VDC 1A max each protected and supervised Monitored points 16 monitored points Z1 to Z16 NO NC without EOL DRY single EOL double EOL and zone inputs 1 fixed function tamper switch input Points maximum wiring AWG 22 600 m 2 000 ft Door strike power supervised 500 mA each or 2 0 Amps total for the KT 400 model JP4 on INT e 1 A each 4 0 Amps total for the KT 400 model JP4 on EXT e 750 mA each 3 0 Amps total for the KT 400 EU model JP4 on INT Auxiliary reader outputs LEDs LED OUT1 and OUT2 and buzzer BUZ for each individual door 25mA max each open collector outputs Relay controlled output 4 onboard Form C Relay controlled outputs 30 VDC 3 Amps max each Communication ports 1 x RS 232 with RJ 12 2 x RS 485 2 x Ethernet 10 100 Base T with RJ 45 Expansion port 1 x SPI 6 pin connector bidirectional data exchange supported Supplies 12 VDC 500 mA max shared with 12 VDC Auxiliary port Auxiliary power 1 x Auxiliary 12 VDC 500 mA maximum shared with SPI expansion port Communication speed 1200 to 115200 Bauds automatic detection over RS 232 and RS 485 10 100 Mb s BaseT over Ethernet Flash memory 256 MB NAND flash for application storage and stand alone event buffer holding 20 000 events RAM memory 128 MB D
18. 30 e IK Rating 04 The KT 400 Ethernet Four Door Controller is capable to meet the EN50131 1 requirements after programming the right parameters as follows e Fora system using memorised information the applicable parameters Invalid attempts before keypad disabled and Keypad disabled duration shall be set to 5 sequential entries of incorrect information along with an access blocking period of minimum 5 minutes afterwards applicable to recognition class 1 e Fora system using a combination of tokens or biometric and memorized information the applicable parameters Invalid attempts before keypad disabled shall be set to maximum 5 sequential entries of incorrect information before an alert is generated at the monitoring console applicable to recognition class 3 The applicable parameter Relock on access shall be set so that the access interface control output is reset when the preset release time has expired or when the APAS is opened e The applicable parameter Input response time for maximum delay time between the occurrence of an event and the annunciation of this event shall be set so that the alert is received at the monitoing console in less than 10 seconds for the worst case configuration of the access control system Please refer to the appropriate section in the EntraPass reference manual e Alerts annunciation at the monitoring console EntraPass shall be programmed to occur when a tamper condition is gene
19. Figure 1 This information is particularly useful when connecting the controller to the rest of the EntraPass system The following table lists all conditions along with a brief description Refer to Table 3 if you must reset or change the communication mode of the KT 400 Ethernet Four Door Controller Table 1 Heartbeat LED Patterns Factory Default DHCP Continuous LONG Pulses Receive Broadcast Single 2 5 Sec Burst Single 0 5 sec burst resume previous flash Card Read or Swipe Firmware Update 5 pulses sec 50 duty cycle Rebooting 10 pulses sec 50 duty cycle 12 DN2003 1202 v01 11 KT 400 Ethernet Four Door Controller Installation Manual Technical Specifications Type Description AC Power input KT 400 Transformer class 2 120 VAC 75VA IN 16 or 24 VAC OUT AC Power input KT 400 EU Transformer 230 50 Hz 100 IN 16 5 VAC OUT Battery back up KT BATT 12 12 VDC 12 Ah battery is recommended when using electromagnet door lock Operating Temperatures For UL listed installations 0 C to 49 C 32 F to 120 F indoor use only For EN50133 compliant installations 5 C to 40 C 41 F to 104 F indoor Group Humidity Level 93 max relative humidity non condensing Cabinet Dimensions 37 59 cm 14 8 in x 30 48 cm 12 0 in x 12 57 cm 4 95 in High Wide Deep Cabinet Weight KT 400 4 0 kg 8 82 Ib Cabinet Weight KT 400 EU 7 0 kg 15 48 Ib PCB dimension 23 11cm 9 1in
20. INCIDEN TAL DAMAGES THE ABOVE LIMITATION MAY NOT APPLY TO YOU d DISCLAIMER OF WARRANTIES THIS WARRANTY CONTAINS THE ENTIRE WARRANTY AND SHALL BE IN LIEU OF ANY AND ALL OTHER WARRANTIES WHETHER EXPRESSED OR IMPLIED INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND OF ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF KANTECH KANTECH MAKES NO OTHER WARRANTIES KANTECH NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON PURPORTING TO ACT ON ITS BEHALF TO MODIFY OR TO CHANGE THIS WARRANTY NOR TO ASSUME FOR IT ANY OTHER WARRANTY OR LIABIL ITY CONCERNING THIS SOFTWARE PRODUCT e EXCLUSIVE REMEDY AND LIMITATION OF WARRANTY UNDER NO CIRCUMSTANCES SHALL KANTECH BE LIABLE FOR ANY SPECIAL INCIDENTAL CONSEQUENTIAL OR INDIRECT DAMAGES BASED UPON BREACH OF WARRANTY BREACH OF CONTRACT NEGLIGENCE STRICT LIABILITY OR ANY OTHER LEGAL THEORY SUCH DAMAGES INCLUDE BUT ARE NOT LIMITED TO LOSS OF PROFITS LOSS OF THE SOFT WARE PRODUCT OR ANY ASSOCIATED EQUIPMENT COST OF CAPITAL COST OF SUBSTITUTE OR REPLACEMENT EQUIP MENT FACILITIES OR SERVICES DOWN TIME PURCHASERS TIME THE CLAIMS OF THIRD PARTIES INCLUDING CUSTOMERS AND INJURY TO PROPERTY WARNING KANTECH recommends that the entire system be completely tested on a regular basis However despite frequent testing vi and due to but not limited to criminal tampering or electrical disruption it is possible for this SOFTWARE PRODUCT t
21. Loosening of terminal connections Damage of conductor insulation Reducing the clearance between SELV Safety Extra Low Voltage circuits and NON POWER Limited Circuits Battery wires Route the battery wires away from the rest of the SELV circuits 7 It is the end user and or installer s responsibility to ensure that the disposal of the used batteries is made according to the waste recovery and recycling regulations applicable to the intended market 8 There are no serviceable parts within the equipment For any issues regarding the equipment please contact your installer 9 Before leaving the premises the Ethernet communication lines must first be connected to an approved acceptable to local authorities type Network Interface Device NID UL installations UL 60950 listed NID for ULC installations CAN CSA C22 2 No 60950 1 Certified NID All wiring shall be performed according to the local electrical codes 10 DISCONNECT POWER BEFORE SERVICING DN2003 1202 v01 11 1 Technical Support For technical assistance with the KT 400 Ethernet Four Door Controller and other Kantech products contact technical support Monday to Friday See the following table for the technical support phone numbers ours North America Toll Free 888 222 1560 GMT 05 00 Direct 450 444 2030 US and Canada Fax 450 444 2029 8 00 to 20 00 kantechsupport tycoint com Latin America GMT 03 00 Direct 5411 4711
22. The normally closed tamper switch must be connected to the dedicated tamper input next to the EGND Note The tamper switch is required for a UL listed installation DN2003 1202 v01 11 19 Connecting 400 Ethernet Four Door Controller Connecting the VC 485 or the USB 485 to the RS 485 Bus O Connect the RS 485 cable to COM1 485 and the RS 485 signal ground to the 12 VDC AUX negative Controllers are linked together through their RS 485 terminals The maximum communication loop length is 1 2 km 4 000 ft using appropriate cabling The RS 485 communication loop should be wired with Ethernet Category 3 double twisted pair network cable or better The RS 485 loop can operate from 1200 to 115200 Bauds under normal conditions Intermittent communication problems or erratic operation may require network speed drops to 9600 or 19200 Bauds Varying the network speed does not perceptibly change the operation speed of the system Note 1 Most installations should be set to 38400 Bauds Note 2 Connecting several KT 400 at a single point is not recommended neither are splitters or spider web star networks Note 3 If the AUX 12 VDC is already used the RS 485 signal ground can be connected to the other GND terminals on the KT 400 The EGND earth ground terminal cannot be used for signal ground only use the GND and AUX 12 VDC negative terminals for signal ground Note 4 There is no end of line resistor to i
23. a secure location providing normal temperature and humidity leaving 23 cm 8 in clear space around all sides and a minimum of 33 cm 13 in clear space in front of the cabinet The location should be easily accessible for servicing the equipment and it is recommended that controllers be located close to the controlled doors Controllers must be located at a minimum distance of 2 m 6 ft from any high voltage equipment or wiring and from electrical equipment susceptible of generating electrical interference at a minimum distance of 1 m 3 ft from telephone equipment or lines and at a minimum of 8 m 25 ft from any transmitting equipment Physical access using keys on controlled doors must be provided so that the KT 400 Ethernet Four Door Controller can easily be accessed for servicing in case of malfunction Earth Grounding AWG 18 grounding wire to EGND The KT 400 Ethernet Four Door Controller uses high performance communication proper grounding must be provided to ensure proper operation Make an earth ground connection to the cabinet of the KT 400 Ethernet Four Door Controller as per the requirements of your local electrical code Wire the E GND terminal on the KT 400 Ethernet Four Door Controller printed circuit board directly to that connection point m X om Door Locking Devices C Connect the door lock device to and LK1 and LK2 and LK3 or and LK4 Note f you
24. chaining which can add up to 15 KT MOD INP16 for a total of 240 external inputs per KT 400 Ethernet Four Door Controller The KT 400 Ethernet Four Door Controller has 16 onboard inputs which gives a total of 256 inputs per controller KT MOD OUT16 The KT MOD OUT16 is a 16 output expansion module Each output is capable of 750 mA It gives the opportunity to address the need for external LED lock relay piezo and buzzer control The module supports daisy chaining which can add up to 16 KT MOD OUT16 modules for a total of 256 external open drain outputs per KT 400 Ethernet Four Door Controller Note The expansion modules support daisy chaining which can add up to 32 KT MOD REL8 modules for a total of 256 external relays per KT 400 Ethernet Four Door Controller Combining input and output expansion modules gives the flexibility to connect up to 256 inputs and 256 outputs DN2003 1202 v01 11 5 Figure 1 KT 400 Ethernet Four Door Controller PCB View THIS solddddy 6 1 1 5 252 54 ENOS 148 ES ES wu 1 Hz SPI PF UZE s O 5 54 TX 50 00 14 1 2 2 OMI Wa coro O gt gt IT I LL
25. condition of normal use shall not be used When the token is marked with an identity number it shall not be a direct representation of the entire coding borne by the token DN2003 1202 v01 11 41 42 KT MPD INP16 and KT MOD OUT16 modules when used in conjunction with KT 400 Access Control Unit shall be installed in the same enclosure with the KT 400 Ethernet Four Door Controller or in separate additional KT enclosure When installed in separarate KT enclosures these enclosures shall be provided each with a tamper detection switch Connect tamper wiring to one available input on the KT MOD INP16 module and program the corresponding input using the EntraPass software Devices Input as a label Tamper input that is programmed in Event parameters to act as an alert when activated Please refer to page 110 of the EntraPass Reference Manual for programming instructions The output on the KT 400 Ethernet Four Door Controller that is intended to be used with a door lock shall be used in conjunction with a separately energized relay in order to provide 30VA galvanic isolation The output shall be programmed using the EntraPass software to activate when an authorized access has been granted to the respective access point All access granted events shall be annunciated at the monitoring console using the EntraPass software Access granted in conjunction with the access granted annunciation at the monitoring console the follo
26. controller is used in a LAN enabled corporate setting use the RJ 45 Ethernet port to connect the controller to the corporate network This method uses existing wiring for data exchange between EntraPass and the controllers Powering the KT 400 Ethernet Four Door Controller Install transformer if applicable Place battery in cabinet Power up the KT 400 Ethernet Four Door Controller The KT 400 must be powered by a wire in or plug in transformer After you have completed all the necessary steps you can power up the KT 400 Connect AC power and connect the battery Once powered check the Heartbeat LED status indicator to determine the communication status and other vital parameters Consult Table 1 for Heartbeat LED behavior identifications If the AC supply is removed the 12 VDC 7 Ah backup battery will support normal operation for up to 12 hours if fully charged Internal battery verification will cutoff battery power if the battery voltage level falls below 9 5 Volts Note The KT 400 will not start on battery power alone Power shall only be applied to the unit when all connections are completed and 7 tested and unit is to be mounted and fixed wall NOTE DO NOT CONNECT TO RECEPTACLE CONTROLLED BY SWITCH SEALED RECHARGKABLE BATTERY 12 VOLT 7 AMP HR 12 BATTERY 7 Ah Part KT BATT 12 For AC Power Wiring LOCKNUT Refer to the Inner Door Sticker Diagrams at the End
27. need external power for ALL the external locks you can use external power supply Connect the power supply to the VIN and GND terminals and put jumper JP4 on EXT When jumper JP4 is on INT the total maximum current draw is 2 3 4 Amp depending on the transformer main power 75 VA 100 VA or When jumper JP4 is on EXT the total maximum current draw is 12 to 28 VDC 4 0 Amps for all configurations with external power supply Check for local magnetic lock regulations LK1 LK2 LK3 and LK4 and terminals are located near the battery BATT terminals The locking device outputs are controlled according to the end user programmed parameters for allowing access to or unlocking doors according to schedules and access levels These doors locking device outputs can operate DC powered locking devices such as electromechanical strikes and can be configured to operate fail safe or fail secure normal or reverse action Note f required the 400 can provide galvanically isolated output s by programming any of the relays DN2003 1202 01 11 17 Note Use 1 K ohm EOL End of Line resistor between and LK terminals if not used Warning Controlled door locks may be governed by regulatory bodies and should always be installed according to local regulations In most instances there are strict limitations to installing fail secure devices and fail safe locking devices such as magne
28. used batteries is made according to the waste recovery and recycling regulations applicable to the intended market Use the recommended battery type ONLY It is strongly advised to have the following tests performed by service persons ONLY 1 Biannual test for battery Remove AC power from the controller and let it work on battery backup power for 30 minutes This test will ensure that in the event of a power failure the battery will be able to support normal operations This test should be performed twice a year Once the test has been performed successfully reconnect AC power to the controller 2 Annual test for emergency lithium battery Measure voltage of lithium battery when power is totally removed from the controller AC DC and backup battery power To ensure maximum operation and to prevent loss of the database contact your KT 400 distributor to return the controller for maintenance if the lithium battery voltage measures below 2 75 VDC DN2003 1202 v01 11 29 Configuring KT 400 Ethernet Four Door Controller with Web Configuration Page This procedure is useful if you want to configure the KT 400 in advance prior to going on site Note The KT 400 Ethernet connection must be done on port 1 Optional Documentation Application Note Networking Basics DN1796 Before you start The detachable Network Configuration Information Sheet is fully completed Determine your connection to the KT 400
29. 3 35 C 55 95 F HVAC system Twenty four hours on standby power shall be provided for the HVAC system The standby power system for the HVAC system may be supplied by an engine driven generator alone A standby battery is not required to be used Amarking to identify the application and signaling function of the product is located on the inside of the unit inner door sticker For certified commercial proprietary control unit accessory applications the requirements of UL 1076 Commercial Proprietary Control Unit Accessory also apply e Use part number KT 3LED PLATE 3 color LED indicators mounted on single plate when the KT 400 is configured with the APOU ALVY KT NCC in an EntraPass Global Edition system for remote alarm monitoring Refer to the KT NCC Installation Manual DN1611 for additional details e he reader s that is are designated to arm or disarm the alarm system must be within the secured side of the customer premises e following Kantech readers have been validated by UL for the UL 1076 Standard P225W26 P225KPW26 P225XSF P225KPXSF P325W26 P325KPW26 P325XSF P325KPXSF and P600 Note All readers can be ordered with or without the following suffixes BEI BEI SE GRY or GRY SE e KT 400 Ethernet Four Door Controller is UL 1076 listed when used with the APOU ALVY KT NCC Network Communications Controller e alarms shall be reported and acknowledged in the following priori
30. 8711 ee Fax 45411 4711 8201 9 00 10 18 00 ingenieria tycoint com Asia GMT 08 00 TSP_SouthEastAsia tycoint com TSP_China tycoint com Asia Pacific 8 30 to 18 00 TSP_India tycoint com TSP_NorthAsia tycoint com TSP_ANZ tycoint com Europe Toll Free 800 CALL TYCO 800 2255 8926 GMT 01 00 8 00 to 18 00 emea support tycoint com United Arab 800 0 31 0 7123 Emirates 44 08701 ADT SUP 44 08701 238 787 United Kingdom Direct 31 475 352 722 Fax 31 475 352 725 2 DN2003 1202 v01 11 400 Ethernet Four Door Controller Installation Manual Overview The KT 400 Ethernet Four Door Controller is designed to meet the highest standards of access control and point monitoring applications Here are the features of the KT 400 Ethernet Four Door Controller Compatible with all EntraPass Special Corporate and Global Editions The KT 400 Ethernet Four Door Controller is compatible with all EntraPass Editions v5 00 and higher EntraPass Special Edition EntraPass Corporate Edition with a Multi site Gateway EntraPass Global Edition with a Multi site Gateway EntraPass Global Edition with a Global Gateway EntraPass Global Edition with a KT NCC Network Communications Controller IP Devices EntraPass The KT 400 Ethernet Four Door Controller can be configured with all EntraPass Editions v5 01 and higher Note AKT 400 Ethernet Four Door Controller firmware download is possible with EntraPas
31. AL WARNING Connecting the red wire lead or power lead of a 5 VDC reader to the 12 VDC terminal may damage the reader See your reader installation procedure for proper power connection Up to 4 readers can be connected to a KT 400 They can be installed on one door to control both entry and exit or on four separate doors operating independently to control one way access The distance between the readers and the KT 400 varies by reader type please consult the installation manual for details Auxiliary outputs provide visual and or audible access operation feedback at the controlled door Outputs READER DOOR 1 OUT1 OUT2 LED amp BUZ are used for the first door READER DOOR 2 OUT1 OUT2 LED amp BUZ are used for the second door READER DOOR 3 OUT1 OUT2 LED amp BUZ are used for the third door and READER DOOR 4 OUT1 OUT2 LED amp BUZ are used for the fourth door DN2003 1202 v01 11 400 Ethernet Four Door Controller Installation Manual READER DOOR 3 READER DOOR 4 5 DO D1 GNDOUT1OUT2LED BUZ 12V 5V DO D1 GNDOUT1OUT2 EAN BUZ 12 p Pr 01 GNDOUT 1OUT2 LED 12V D UT DO D1 GNDOUT 1OUT2 LED a 12 1 1 READER DOOR 2 IMPORTANT This diagram is an example of readers can be connected to a KT 400 You cannot connect ABA and Proximity readers on the same KT 400 LIO ee READER ABA READER GREEN
32. CONNECTED TO 400 BEFORE STARTING A GROUP OF OUTPUT MODULES KT MOD REL8 and KT MOD OUT16 THROUGH THE SPI EXPANSION CONNECTOR SPI EXP SPI OUT KT MOD INP16 KT 400 Expansion Module 16 Zone ee with SPI Cable KANTECH M ZONES INPUT MODULES KT MOD INP16 ONLY RED YELLOW JP1 2 JP4 Fast NO tO ied t DRY Siow NC REGULATED POWER SELI SUPPLY 12 VDC 2 Amps CONNECTION FROM KT 400 or PREVIOUS INPUT MODLILE NC DRY CONTACT HO DRY CONTACT DRY CONTACT No DRY CONTACT INPLIT DEFINED INFUT DEFINED INPUT DEFINED INFUT DEFINED WITHOUT EOL RESISTOR WITHOUT EOL RESISTOR WITH EOL RESISTOR WITH EOL RESISTOR See ee ee Se ee SS SSS SSS SSS ee LLL S SS CONFIGURATIONS FOR THE SIXT EEN ZONE INPUTS DEFINED THROUGH JUMPERS ta KT MOD REL8 KT 400 Expansion Module 8 Relay with SPI Cable SPI OUT CONNECTION TO OUTPUT tyco 2007 08 8 RELAYS num SPI MODULES ONLY KT MOD REL8 Ej 0801 1 and KT MOD OUT16 niu ni RED wx O 000000 WHITE YELLOW BLUE GREEN YELLOW WHITE RED 134 Ma REGULATED POWER CONNECTION FROM 400 SUPPLY 12 VDC 2 or PREVIOUS OUTPUT MODULE or SPI EXPANSION PORT FROM 1st KT MOD INP16 T
33. DRe for application loading and running Network autonomy Distributed data and processing Certifications Listing EN50133 1 EN55022 EN60950 1 EN61000 6 1 EN61000 6 2 FCC Part15 ICES Class A UL 294 UL 1076 C Tick Note The KT 400 is capable of restarting automatically after total power loss and will keep the programming for more than 120 hours of power interruption The design is using flash memory for saving access rules This is certified by Telefication under the requirements of EN50133 1 Recognition Class 0 3 Access Class A B Environmental Class II DN2003 1202 01 11 13 Electrical Specifications AUXILIARY READER OUTPUTS MAXIMUM CURRENT COMBINED MAXIMUM Typical CURRENT LEDs LED OUT1 and OUT2 for each door reader 25 mA each Buzzer BUZ for each door reader 25 mA each OUTPUTS MAXIMUM CURRENT gt 500 3 Amps for KT 400 P P P 4 0 Amps for KT 400EU 4 for Controlled Readers 11 2 to 13 75 VDC 5 0 Amps with optional 4 for Controlled Readers 5 VDC 4 for Locks 11 2 to 13 75 VDC when jumper JP4 is on INT 2 0 Amps for KT 400 internal 3 0 Amps for KT 400EU 4 0 Amps with optional 4 for Locks 12 to 28 VDC when jumper JP4 is on EXT 4 0 Amps for both models external KT 400 Ethernet Four Door Controller Models Expansion Modules Models Related Documentation and Miscellaneous Items KT 400 Ethernet Four Door Controller Models KT 400 KT 400 Ethernet Four Do
34. EntraPass as well as the communication port which can be IP ETHERNET 1 RS 485 COM1 or RS 232 COM3 4 DN2003 1202 v01 11 400 Ethernet Four Door Controller Installation Manual Downloadable Firmware The firmware program can be downloaded from any EntraPass workstation to the KT 400 Ethernet Four Door Controller The firmware program stored in the controller s flash memory is upgraded without having to change any parts Trouble and Reporting The KT 400 Ethernet Four Door Controller constantly supervises ac power and battery condition and reports AC Lost Normal Battery Low Battery Battery Critical or No Battery status to the EntraPass system Power outputs are Supervised and electronically protected against short circuits and surges Locking devices are also supervised for short and open circuits Visual Status Indicators LEDs The KT 400 Ethernet Four Door Controller has multiple status indicators such as for troubleshooting network activity power status and outputs activity See Figure 1 for their locations Heartbeat BLUE The Heartbeat blue LED indicates the communication status with EntraPass or the IP mode of the controller Refer to Table 1 for a descriptions of the heartbeat patterns Diagnostic RED The DIAG red LED is for factory diagnostics and should never be seen on otherwise Active YELLOW This LED signals activity on the SPI expansion port COM1 RX COM1 T
35. KT 400 Ethernet Four Door Controller Installation Manual DN2003 1202 V01 11 400 Door Controller Installation Manual Table of contents DO LOTO 1 eoe aim nike 1 InstrHollOFls a a 1 Technical um d hee ae o eA cC tee ee 2 Gu 3 Compatible with all EntraPass Special Corporate and Global Editions 3 OOS ae 3 Fouronboard doors RAT 3 COmMU UNICANON POLIS toin ee 3 IP srei LEES 3 Me cA EMILE 4 Noe Sen qv EE 4 e M 4 Reader SUNRISE 4 sad ee EP E team EL ee 4 Elevator IM RIO vce man 4 Alarm Panel LCM ganic Sunes A cM cM ue I D et ca 4 AUTOIMAUG POM pesto sut Date ood Pause a E 4 Downloadable Firmware
36. Software Product Transfer You may transfer all of Your rights under this EULA only as part of a permanent sale or transfer of the HARDWARE provided You retain no copies You transfer all of the SOFTWARE PRODUCT including all component parts the media and printed materials any upgrades and this EULA and provided the recipient agrees to the terms of this EULA If the SOFTWARE V KT 400 Ethernet Four Door Controller Installation Manual PRODUCT is an upgrade any transfer must also include all prior versions of the SOFTWARE PRODUCT f Termination Without prejudice to any other rights KANTECH may terminate this EULA if You fail to comply with the terms and condi tions of this EULA In such event You must destroy all copies of the SOFTWARE PRODUCT and all of its component parts 9 Trademarks This EULA does not grant You any rights in connection with any trademarks or service marks of KANTECH or its suppli ers COPYRIGHT All title and intellectual property rights in and to the SOFTWARE PRODUCT including but not limited to any images photographs and text incorporated into the SOFTWARE PRODUCT the accompanying printed materials and any copies of the SOFTWARE PRODUCT are owned by KANTECH or its suppliers You may not copy the printed materials accompanying the SOFTWARE PRODUCT All title and intellectual property rights in and to the content which may be accessed through use of the SOFTWARE PRODUCT are the property of the respective
37. X COM2 RX COM2 TX RS232 RX and RS232 TX YELLOW The six serial port LEDs transmit receive activity indicators LOCK1 LOCK2 LOCK3 LOCKA RED Each lock output Open Drain has an indicator which turns on each time the corresponding output is activated RELAY1 RELAY2 RELAY3 and RELAY4 RED Each relay output has an indicator which turns on each time the corresponding relay is activated AC PWR and DC PWR GREEN The AC PWR LED is ON when AC power is present The DC PWR is ON when the DC level is sufficient for all DC terminals such as the 12V AUX For further details see Troubleshooting on page 28 section ETH1 ETH2 LINK GREEN The LED is OFF when there is no Ethernet network or the cable is disconnected and ON when there is an Ethernet cable and network connection ETH1 ETH2 TXRX YELLOW The LED indicates network activity Built in SPI Expansion The KT 400 Ethernet Four Door Controller allows connection of expansion modules in order to add outputs like relays and open drain outputs and inputs See Figure 10 and Figure 11 for an example with expansion modules KT MOD REL8 The KT MOD REL8 is an 8 relay expansion module Each relay is 3 Amps 30 VDC Form C The module supports daisy chaining which add to 32 KT MOD REL8 modules for a total of 256 relay outputs per KT 400 Ethernet Four Door Controller KT MOD INP16 The KT MOD INP16 is a 16 zone input expansion module The module supports daisy
38. a network WAN DN2003 1202 v01 11 3 Inputs There are 16 onboard inputs on the KT 400 Ethernet Four Door Controller Up to 240 more can be added through the addition of expansion modules such as the KT MOD INP16 for a total of 256 inputs If using the KT MOD INP16 input module as double end of line resistor there is a128 inputs limitiation Each input can be individually configured for one of the following application Door contact 4 onboard e T Rex Request to Exit Detector 4 onboard e Interlock 4 onboard e Floor Selection for Elevator Application Elevator Action e External Alarm System Status Armed e External Alarm System Alarm Alarm Secure e External Alarm System Zones Relays to trigger on each input in alarm event e Zone shunt Single or group of zones can be permanently or temporarily shunted to a secure state on the same controller Shunt method includes Zone Shunt by another Zone When a zone in alarm is programmed to shunt another zone group of zones Zone Shunt on Unlock When a zone is temporarily frozen to its actual state alarm or secured after an access granted Manual Shunt Operator can manually Shunt a zone to a secure state Disarmed Door Shunt When alarm system is disarmed some zones may be Shunted to a secure state Entry Exit Delay Shunt When a user is in the process of disarming arming the alarm system and entry exit delay
39. anchors Spaenaur EX 5 or equivalent not included Note 5 A time lag fuse of 630 is included with the fuse block terminal If replacement is needed only use recommended type 250VA 630mA Time lag approved must meet EN60127 1 2 3 16 DN2003 1202 v01 11 KT 400 Ethernet Four Door Controller Installation Manual Installing the KT 400 Ethernet Four Door Controller Preparing to Install the KT 400 Ethernet Four Door Controller O Required to install KT 400 Ethernet Four Door Controller e For North America AC transformer 120 VAC 60 Hz IN 16 24 VAC 75 VA OUT class 2 not included 75 VA transformer e For EMEA Europe Middle East and Asia AC transformer 230 50 Hz IN 100 VA OUT included in KT 400 EU e One battery 12 VDC 7 Ah not included A visual inspection should be made when unpacking the KT 400 Ethernet Four Door Controller Any missing item part or damaged component should be reported immediately Physical Installation Check for ideal indoor location Stay away from electrical or communication devices The KT 400 cabinet has been designed to be mounted on a wall without any additional enclosures The cabinet is large enough to accommodate the battery backup supply and the necessary wiring connections for most applications EMT Electrical Metallic Tubing conduit Knockouts are provided in 1 9 cm 0 75 in on all sides of the cabinet The cabinet should be mounted indoors in
40. and choose the appropriate network cable that you need Make sure the KT 400 is in Forced Default Static mode before starting the configuration Verify the heartbeat patterns to determine the status See Table 3 on page 28 for details Start your web browser and enter the following IP 192 168 1 2 and press Enter pod 6 Configuration page d v ib Page Tools Firmware 1 11 01 Hardware Revoi Web Configuration EntraPass Gateway IP Address 0 0 0 0 Domain name Domain name resolution Ethernet 1 MAC Address 00 50 F9 50 0A F0 DHCP Local IP Address 0 0 0 0 Subnet Mask 0 0 0 0 Gateway address 0 0 0 0 DNS Address 0 0 0 0 Protocol UDP Port 18810 Save configuration to KT 400 Tyco International All Rights Reserved tyco Home About Tyco Contact Us Note Even though the KT 400 is in Forced Default Static mode the DHCP status displays Enable Make sure to change it ON OO A 30 accordingly when entering the parameters from the Network Configuration Information Sheet Put a jumper on JP3 Both jumpers should now be on JP2 and JP3 Enter the IP addresses as per the Network Configuration Information Sheet Select a Protocol TCP or UDP Enter a Port UDP only Click on Save configuration to KT 400 When you will go to the site with the configured KT 400 you will have to enter the same details into the EntraPass workstation DN2003 1202 v01 11
41. content owner and may be protected by applicable copyright or other intellectual property laws and treaties This EULA grants You no rights to use such content All rights not expressly granted under this EULA are reserved by KANTECH and its suppliers 4 EXPORT RESTRICTIONS You agree that You will not export or re export the SOFTWARE PRODUCT to any country person or entity subject to US export restric tions 5 CHOICE OF LAW This Software License Agreement is governed by the laws of the State of New York 6 LIMITED WARRANTY a NO WARRANTY KANTECH PROVIDES THE SOFTWARE AS IS WITHOUT WARRANTY KANTECH DOES NOT WARRANT THAT THE SOFTWARE WILL MEET YOUR REQUIREMENTS OR THAT OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED OR ERROR FREE b CHANGES IN OPERATING ENVIRONMENT KANTECH shall not be responsible for problems caused by changes in the operating characteristics of the HARDWARE or for prob lems in the interaction of the SOFTWARE PRODUCT with non KANTECH SOFTWARE or HARDWARE PRODUCTS LIMITATION OF LIABILITY WARRANTY REFLECTS ALLOCATION OF RISK IN ANY EVENT IF ANY STATUTE IMPLIES WARRANTIES OR CONDITIONS NOT D IN THIS LICENSE AGREEMENT KANTECH S ENTIRE LIABILITY UNDER ANY PROVISION OF THIS LICENSE AGREEMENT SHALL BE LIMITED TO THE GREATER OF THE AMOUNT ACTUALLY PAID BY YOU TO LICENSE THE SOFTWARE PRODUCT AND FIVE US DOLLARS USD 5 00 BECAUSE SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR
42. e only UL 294 or UL 1076 listed power supply Connect Kantech part number KT ACPW LED status indicator to the AC terminals of the KT 400 Use Kantech part number KT BATT 12 battery see Note Note Using a 12V 7Ah battery backup battery provides a minimum of 4 hours as per Section 33 of UL 294 fifth edition UL 1076 Compliance Notice The KT 400 is UL 1076 Listed as a Commercial Proprietary Control Unit Accessory and Proprietary Burglar Alarm Unit Section 83 2 with EntraPass and Redundant Server alarm system features KT 300 Controllers ioProx Proximity readers and TRex request to exit devices other sensor devices temperature water level etc may be used as long as they are also UL 1076 Listed The EntraPass and Redundant Server shall be running at all time and manned 24 hours a day 365 days a year The EntraPass and Redundant Server will each have their own operator workstation Data processing equipment and office appliance and business equipment used as central supervisory equipment Station shall be listed to Information Technology Equipment UL 60950 1 Should the EntraPass and or Redundant Server be replaced a UL 60950 1 listed computer must be used The following recommended system requirements apply to the EntraPass Server Redundant Server Video Vault Card Gateway SmartLink and Workstation e Operating Systems Windows 2000 XP 2003 2008 Windows 7 Standard and Enterprise Server Editions Vista e Processor Dua
43. ect auxiliary outputs to readers and local warning devices Tamper Protection install tamper switch on cabinet Connecting the KT 400 Ethernet Four Door Controller Connecting the VC 485 or the USB 485 to the RS 485 Bus Connect the RS 485 cable to 1 485 and the RS 485 signal ground to the 12 VDC AUX negative Connecting the Master Controller to the Host PC 0 Connect the RS 232 flat cable from the KT 400 to the PC Connecting Expansion Modules to the KT 400 SPI Expansion Port Make sure input and output expansion modules are not in the same SPI group Calculate maximum current draw and connect external power supply ies to expansion module s if required Make sure the power jumper on the modules is in the correct position when using external power supply ies Powering the KT 400 Ethernet Four Door Controller Install the transformer or DC power supply if applicable Place battery in cabinet Power up the KT 400 Ethernet Four Door Controller DN2003 1202 v01 11 35 eme n EN EE mma 0 D mE DOOR Z5 NO or NC EOL DRY or DEOL re wenn _ sas re 6888 Marne HEEL EOL ORF DEOL Relay Outputs i _ ren l1 1 4 36 0 2003 1202 v01 11 KT 400 Ethern
44. em Internet Firewall KT 300 up to 31 up to 31 DN2003 1202 v01 11 Figure 5 USB 485 with EntraPass Special and Corporate Editions with Multi site Gateway EntraPass Special Edition and Multi site Gateway USB 485 up to 32 Figure 6 VC 485 with EntraPass Global Edition and Global or Multi site Gateway EntraPass Global Edition with Global or Multi site Gateway DB9 RS 232 VC 485 AS 232 RG 485 CONVERTER f 2 UD 7 vu KT 400 up to 32 Use the DB9F to RJ 12 adaptor 740 1022 included in the VC 485 kit 10 DN2003 1202 v01 11 KT 400 Ethernet Four Door Controller Installation Manual Figure 7 Over the Internet with a KT NCC and EntraPass Global Edition EntraPass Global Edition 52 8 b SS KT 400 up to 32 Figure 8 Over RS 232 straight from the EntraPass RS 232 COM port EntraPass Special Corporate and Global Edition 089 RS 232 CYAN B 400 Master Controller KT 400 up to 31 Use the DB9F to RJ 12 adaptor 740 1023 included in the CBLK 10 kit The maximum length for the RS 232 cable is 30 m 100 ft DN2003 1202 v01 11 11 Heartbeat LED Patterns Communication status and other vital controller parameters can be obtained from heartbeat LED patterns It is located near the center of the board see
45. en each modules cannot exceed 1 m 3 ft Shielded wire should only be used in areas with excessive RF noise of electromagnetic interference Keep in mind that the expansion modules must be defined in the EntraPass system when they are installed Rule 3 There is already 4 relays available on the KT 400 Ethernet Four Door Controller Don t forget to check the relays number assignments to prevent redundancy unless it has been planned on purpose For more details concerning the expansion modules refer to the following documents DN1775 KT MOD INP16 Install Sheet French version DN1776 KT MOD INP16 Install Sheet English version DN1780 KT MOD OUT 16 Install Sheet French version DN1781 KT MOD OUT 16 Install Sheet English version DN1785 KT MOD REL8 Install Sheet French version DN1786 KT MOD REL8 Install Sheet English version DN1805 KT MOD CAB Install Sheet French version DN1806 KT MOD CAB Install Sheet English version DN1833 KT MOD CABEU Install Sheet French version DN1834 KT MOD CABEU Install Sheet English version DN1790 KT MOD INP16 OUT16 and REL8 Expansion Modules Dimensions Drawing DN1792 KT MOD CAB Dimensions Drawing DN1794 KT MOD CABEU Dimensions Drawing DN1795 KT MP200 Mounting Plate for KT MOD INP16 OUT16 and REL8 Expansion Modules Dimensions Drawing DN2003 1202 v01 11 23 Figure 10 PCB View of Expansion Modules SPI EXPANSION IMPORTANT THE KT MOD INP18 SPI IN TB 1 MUST BE
46. et Four Door Controller Installation Manual Figure 14 KT 400 Cabinet Inner Door Sticker Diagram North America Note regarding output voltage reongs Auxiliary Power 11 2 13 75 12 VDC Readers 11 2 to 13 75 5 VDC Readers 5 Locks with internal power JP4 on INT 11 2 to 13 75 VDC ETHERNET 1 and 2 TO Locks with extemal power on EXT 11 2 to 28 VDC ETHERNET NETWORK LOW SPEED RS 232 1200 113200 BAUD DEVICE FIN EXPANSION PORT FOR EXPANSION MODULES IF Jez Ps RESET JP2 HARD JP3 RESET DOOR 1 REQUEST JP2 EXIT DEVICE JEFAULT e STATIC FACTORY DEFAULT DHCP Cx 1 2 s I TL LEX TRD IOPROX P325KP READER WITH E INTEGRATED KEYPAD SEE NOTE bed TIT DEI LIT II te T EE ara Fo 1 S AO dro 5 mmm m mmm m m m m mm TIME CET m meme mmm mmm mm mm mmm jm mm mmm mmm mm mmm oleae Nu VOLTAGE mu m m m a m e e KT ACPW LED
47. heet Please complete one sheet per KT 400 Ethernet Four Door Controller Company Name Site Name L LAN or WAN see other side Configuration in a Local Area Network LAN EntraPass Workstation EntraPass Multi site Gateway Router For more details please refer to the EntraPass Reference Manual MAC Address 00 50 F9 Protocol Port 18810 by Default or UDP only IP Address Type 0 DHCP Static IP Address Subnet Mask Default Gateway Router EntraPass Special Edition Multi site Gateway IP Address DN2003 1202 v01 11 33 Configuration a Wide Area Network WAN EntraPass Special Edition Multi site Gateway WAN Internet Router with Router with public IP address public IP address Note Ethernet connections are not to be used for off premise communication in UL installations EntraPass Site For more details please refer to the EntraPass Reference Manual EntraPass Special Edition Multi site Gateway IP Address Router Public IP Address Domain name Port Forwarding Checklist For more details please refer to the EntraPass Reference Manual EntraPass Gateway Ports L 18001 UDP and LJ 18801 UDP or 18802 TCP KT 400 Ethernet Four Door Controller Site MAC Address 00 50 F9 IP Address Static Reserved DHCP IP Address Subnet Mask Default Gateway Router DNS Server IP Address
48. l Core e 2 GB e Minimum hard disk space 20 GB e Color depth 24 bit 16 million colors required for Video Integration only e Screen resolution 1024 x 768 e AGP or PCI Express 8X graphics card with 64 MB memory and DirectX 9 0 support e Network Interface card 10 100 Base T network adaptor Note Actual requirements may vary based on your operating system and configuration DN2003 1202 v01 11 39 40 e Central Supervisory Equipment shall employ supply line transient protection complying with the Standard for Transient Voltage Surge Suppressors UL 1449 with a maximum marked rating of 330 V e Central Supervisory Equipment shall employ signal line Transient protection complying with the Standard for Protectors for Data Communications and Fire Alarm Circuits UL 497B with a maximum marked rating of 50 V e The Central Supervisory Equipment shall employ that communication circuits and network components connected to the telecommunications network shall be protected by secondary protectors for communication circuits These protectors shall comply with the Standard for Secondary Protectors for Communications Circuits UL 497A These protectors shall be used only in the protected site of the telecommunications network e The Central Supervisory Equipment shall be installed in a temperature controlled environment A temperature controlled environment is defined as one that can be maintained between 1
49. m 19 er __ _ 19 Connecting the KT 400 Ethernet Four Door Controller 20 Connecting 485 or the USB 485 to the RS 485 Bus 20 Connecting over Corporate Network LAN 21 Powering the KT 400 Ethernet Four Door Controller 21 SPI Expahsion POL aside Cr eee 23 Important Installation Rules about Expansion Modules 24 SIO OTN Mem 28 29 How to reset the KT 400 Ethernet Four Door Controller for Factory Default DHCP mode 29 KT 400 Ethernet Four Door Controller Maintenance Recommendations 30 Configuring the KT 400 Ethernet Four Door Controller with the Web Configuration Page 31 Optional Documentation seeeeesssssssseeeeeeeeennen nennen nnne 31 Configuring the KT 400 Ethernet Four Door Controller with the KT Finder 32 Installation Checklist 36 Inputs and Outputs Assignments 2 ei o 37 dr H 39
50. n port without an additional external power supply can vary depending how much current is drawn from all the modules in the SPI chain Check the following table to calculate the SPI chain current draw Expansion Module Qty of modules x Maximum current draw Current REL8 X mA KT MOD OUT16 x 750 mA Maximum current draw from KT 400 SPI expansion port when the 12 VDC AUX terminals are not used 500 mA If the total current is between 0 mA and 1850 mA 1 85 Amps 1 external power supply is required If the total current is between 1851 mA and 3700 mA 3 70 Amps 2 external power supplies are required Example of current draw calculation 1 15 modules KT MOD OUT16 x 750 mA 11250 mA 11250 mA 500 mA or 0 mA if the 12 VDC AUX of the KT 400 is used 10750 mA 10750 mA divided by 1850 mA 5 8 which means in fact 6 external power supplies 12 VDC 2 Amps are required Connect an external power supply at every expansion module where the current draw has reached 1 85 Amps Make sure the power jumper on the modules is in the correct position when using external power supply ies Qr mw 19 22 DN2003 1202 v01 11 KT 400 Ethernet Four Door Controller Installation Manual Important Installation Rules about Expansion Modules Note 1 The maximum current draw must be calculate each time there 15 a new module added to the SPI chain Rule 2 The SPI cable between the KT 400 and the 1st module or betwe
51. nstall on the RS 485 COM1 terminals on the last KT 400 controller of a loop To RS 232 Port 9 Preferred for Global Edition Up to 1 2 Km 4000 ft to the last controller ORANGE _ BLUE S8t BHsr To USB Port WHITE USB 485 Prefered for special Edition and 2 2 Corporate Edition mma xm im Note 5 f you must make up your own RS 232 cable with a RJ 12 connector refer to the following diagram for the RJ 12 pin out 6 CTS WHITE 7 5 GND BLACK 4 RX RED gt gt 3 TX GREEN 2 GND YELLOW 1 RTS BLUE 20 DN2003 1202 v01 11 KT 400 Ethernet Four Door Controller Installation Manual Connecting the Master Controller to the Host PC via RS 232 L Connect RS 232 cable from KT 400 to the PC maximum length 30 m 100 ft If the local master controller is located more than 30 m 100 ft from the host computer you must use a VC 485 or USB 485 interface Note 1 The CBLK 10 kit includes 30 m 100 ft of RS 232 cable with RJ 12 connectors and the 740 1023 DB9F to RJ 12 adaptor Note 2 you must make up your own 5 232 cable with RJ 12 connectors refer to the following diagram for the RJ 12 pin out RJ 12 RJ 12 clip down clip down 6 CTS WHITE 6 CTS WHITE 5 GND BLACK RS 232 Cable 5 GND BLACK 4 RED 4 RED 3 TX GREEN 2 GND YELLOW 2 GND YELLOW 1 RTS BLUE 1 RTS BLUE Connecting over Corporate Network LAN If the master
52. o fail to perform as expected KT 400 Ethernet Four Door Controller Installation Manual Pre Installation Information To the Installer If you are familiar with the installation you can use the installation checklist on page 36 with the symbol Copyright Information Copyright 2012 Tyco International Ltd and its Respective Companies All Rights Reserved All specifications were current as of publication date and are subject to change without prior notice EntraPass Kantech and the Kantech logo are trademarks of Tyco International Ltd and its Respective Companies Safety Instructions Important NEVER INSTALL THE EQUIPMENT DURING A LIGHTNING STORM This equipment KT 400 Ethernet Four Door Controller Model KT 400 EU shall be used installed and used within an environment that provides the pollution degree max 2 and over voltages category NON HAZARDOUS LOCATIONS INDOOR only The equipment is FIXED and PERMANENTLY CONNECTED and is designed to be installed by Service Persons only service person is defined as a person having the appropriate technical training and experience necessary to be aware of hazards to which that person may be exposed in performing a task and of measures to minimize the risks to that person or other persons The equipment is installed in a metallic cabinet that meets the applicable requirements for a FIRE ENCLOSURE Note When installed on the North American Market powered via the UL cUL Listed 75VA Transfo
53. of the Document EARTH GROUND DN2003 1202 v01 11 21 SPI Expansion Port The SPI Serial Peripheral Interface expansion port on the KT 400 is used to connect expansion modules in order to add more inputs and outputs such as relays The maximum current draw for the SPI expansion port is 500 mA when the 12V AUX terminals are not used The 6 pin SPI cable must be connected to the SPI IN of the first module See Figure 9 and Figure 11 for examples of interconnection between the KT 400 and expansion modules Figure 9 KT 400 Interconnection Examples with Expansion Modules KT 400 Controller with 4 Relays and 16 Zone Inputs C KT MOD INP16 KT MOD INP16 ue KT MOD INP16 1 Use path when combining input KT MOD INP16 and output KT MOD REL8 and KT MOD OUT 16 modules You must use the SPI expansion port SPI EXP of the 1st input module to add a group of output modules 2 Use path B when connecting ONLY OUTPUT modules KT MOD REL8 and KT MOD OUT 16 3 Use path C when connecting ONLY INPUT modules KT MOD INP 16 4 The maximum number of inputs is 256 16 x KT MOD INP 16 5 The maximum number of outputs is 256 16 x 0 16 32 x KT MOD REL8 or any combination giving 256 outputs 6 Maximum current draw must be planned use external 12 VDC 2 Amps power supply ies when required The number of expansion modules that can be connected to the KT 400 SPI expansio
54. or Controller IP Ready with Accessory Kit in Metal Cabinet see Table 2 KT 400 EU KT 400 Ethernet Four Door Controller IP Ready with Accessory Kit in Metal Cabinet European Union Model see Table 2 400 KT 400 Ethernet Four Door Controller PCB only IP Ready with Accessory Kit see Table 2 KT 400 CAB KT 400 Black Metal Cabinet with Lock and Keys see Table 2 KT 400 CABEU KT 400 Black Metal Cabinet with Lock and Keys European Union Model see Table 2 Expansion Modules Models KT MOD INP16 KT 400 Expansion Module 16 Zone Inputs with SPI Cable 41 cm 16 in KT MOD REL8 KT 400 Expansion Module 8 Relay with SPI Cable 41 cm 16 in KT MOD OUT16 KT 400 Expansion Module 16 Output with SPI Cable 41 cm 16 in KT MOD CAB KT 400 Expansion Module Cabinet Black with SPI Cable 91 cm 36 in Lock and Two Keys KT MOD CABEU KT 400 Expansion Module Cabinet Black with Electrical Parts SPI Cable 91 cm 36 in Lock and Two Keys European Union Model KT MOD SPI 16 KT 400 SPI Cable 41 cm 16 in for SPI Interconnection within the Cabinet KT MOD SPI 36 KT 400 SPI Cable 91 cm 36 in for SPI Interconnection between Cabinets Related Documentation DN1420 EntraPass Special Edition Reference Manual English version 14 DN2003 1202 v01 11 400 Ethernet Four Door Controller Installation Manual Part number Description DN1415 EntraPass Corporate Edition Reference Manual English version Related Documentation continued
55. or Controller Maintenance Recommendations Important Only a service person shall perform the following maintenance recommendations The KT 400 includes a lithium CR2032 primary battery see the KT 400 Ethernet Four Door Controller PCB View on page 6 This battery must be replaced by a service person ONLY to avoid any risk of explosion If the lithium battery stops working please contact the service person for maintenance if the lithium battery voltage measures below 2 75 VDC Do not crush puncture open disassemble or otherwise mechanically interfere with the battery Do not try to recharge the battery If you need to dispose of the PCB and or the lithium battery wrap the KT 400 in non conductive tape Check with your local authorities for battery disposal regulations Warning Do not store the batteries in such a way that they come into contact with each other or with any piece of metal Explosion or fire may occur Should fire occur use only dry chemical fire extinguishers Do not use water to put out the fire Do not heat the batteries Do not dispose of the batteries or PCB in a fire Do not disassemble the batteries Do not apply pressure to or deform the batteries Ensure that the above precautions are strictly observed by related departments including but not limited to production sales and outside contractors Regarding the recommended backup battery 12 VDC 7 Ah It is the service person s responsibility to assure that the disposal of
56. prevails some zones may be Shunted to a secure state e Arming Disarming Request e Postpone Arming Request Tamper switch input The tamper switch is a non programmable Fixed Function input It is used to identify tampering of the KT 400 cabinet Lock Outputs There are 4 onboard lock outputs and they are supervised The locking function can also be performed by any onboard relay configured for this functionality Relay Outputs There are 4 onboard relay outputs Up to 256 relay outputs can be supported through the addition of expansion modules such as the KT MOD REL8 Reader Outputs There are 4 different possible outputs for each of the 4 onboard reader interfaces for a total of 16 programmable outputs Reader outputs are used to give user visual and or audible feedback on the ongoing access events Reader Interfaces There are 4 onboard reader interfaces They can be programmed for Wiegand or ABA Clock and Data readers Elevator Interface The KT 400 Ethernet Four Door Controller supports elevator interfacing with the addition of expansion modules such as the KT MOD REL8 KT MOD INP16 and KT MOD OUT16 Alarm Panel Interface The KT 400 Ethernet Four Door Controller supports alarm panel interfacing with the appropriate connections made between zone inputs relay outputs and the alarm system panel Automatic Port Detection The KT 400 Ethernet Four Door Controller automatically detects the site communication speed set by
57. rated an access point is opened without granted access or if the access point remains open longer than the allowed period of time e The KT 400 Ethernet Four Door Controller shall be used in conjunction with EntraPass in order to be able to annunciate these events for all recognition classes All these events are displayed immediately in the Global Edition of EntraPass software within less than 10 seconds from the time the event is received e When the KT 400 Ethernet Four Door Controller is using a combination of tokens or biometric and memorized information recognition class 3 it shall be programmed so that it will give an alert after a maximum of 5 sequential entries of invalid memorized information with the same token or biometric The alert shall be received at the monitoring console in less than 10 seconds e Recognition class 2 and shall use only access point readers for which the false acceptance rate is less than 0 01 and the false rejection rate is less than 1 e The memorized information PIN used in conjunction with the token or biometric recognition class 2 and 3 shall have a minimum number of differs of 10 000 The KT 400 Ethernet Four Door Controller is using 5 or 6 digit codes as PIN numbers Please refer to page 232 of the EntraPass Reference Manual For recognition class 3 only 6 digits PIN numbers shall be used e Tokens with coding systems visible to the unaided human eye and therefore usually easy to duplicate under
58. rmer the KT 400 Ethernet Four Door Controller shall be connected to the mains by a LICENSED ELECTRICIAN in accordance with the applicable rules of the National Electrical Code or Canadian Electrical Code regarding this type of connection 1 The connection to the mains supply must be made as per the local authorities rules and regulations In the UK as per BS6701 An appropriate disconnect device must be provided as part of the building installation Where it is not possible to rely on the identification of the NEUTRAL in the AC MAINS SUPPLY the disconnecting device must disconnect both poles simultaneously LINE and NEUTRAL 2 AVOID setting up the equipment near heaters air conditioners ventilators and or refrigerators DO NOT select a place that exposes your controller to direct sunlight excessive heat moisture vapors chemicals or dust 3 If during the installation a knockout on the cabinet is removed it is the installer s responsibility to ensure that the same degree of protection for the cabinet is provided by the use of bushings fittings adequate sealant etc 4 The metallic cabinet must be secured to the building structure before operation Use four 4 stainless steel tapping screws 8 32 mm 1 25 in to mount the cabinet 5 he ground connection must be as shown within the included diagram or equivalent 6 Internal wiring must be routed in a manner that prevents Excessive strain on wire and on terminal connections
59. s v4 01 and higher Web Configuration Page The Web Configuration Page is accessible through any browser It can be used to verify and configure the IP settings of the following Kantech devices the KT 400 Ethernet Four Door Controller the KT NCC and the Kantech IP Link Refer to the procedure Configuring the KT 400 Ethernet Four Door Controller with the Web Configuration Page on page 31 for further details KT Finder The KT Finder is a stand alone application that can be used to verify and configure the IP settings of the following Kantech devices the KT 400 Ethernet Four Door Controller the KT NCC KTES and the Kantech IP Link The Kantech device can be located within the same LAN or in a remote location over the internet Refer to the procedure Configuring the KT 400 Ethernet Four Door Controller with the KT Finder on page 32 for further details Four Onboard doors The KT 400 Ethernet Four Door Controller is a full 4 onboard doors access controller See Figure 1 for a description of the PCB and Figure 2 for all the connection possibilities offered by the KT 400 Ethernet Four Door Controller Communication Ports 110 100Base T ETH1 Ethernet for network connection with the EntraPass Gateway e 110 100Base T ETH2 Ethernet for network connection with intelligent IP peripherals e 1 RS 232 for communication with EntraPass e 1 RS 485 COM1 for communication with EntraPass or loop of controllers e 1 RS 485 COMO for RS 485 comm
60. tic locks or other similar locking devices on doors used as emergency exits Hooking Up Inputs Connect devices to inputs 1 to 16 0 Resistors for all inputs 5 6K ohm if selected The KT 400 has an on board capability of monitoring 16 input points expandable to 256 with expansion modules Each onboard input is supervised with or without end of line resistors 5 6K ohm The maximum distance of one line is 600 m 2 000 ft with AWG 22 in a single or double EOL configuration Note Onboard Inputs can be defined with none single or double EOL End of Line resistor s according to your EntraPass software settings Inputs 1 2 are automatically reserved for the first controlled door The contact is assigned input 1 and the associated request to exit detector as input 2 Inputs 5 and 6 are automatically reserved for the second controlled door The contact is assigned input 5 and the associated request to exit detector as input 6 Inputs 9 and 10 are automatically reserved for the third controlled door Inputs 13 and 14 are automatically reserved for the fourth controlled door There is no obligation to follow these rules but this standard convention facilitates servicing DOOR 1 CONTACT 22 XdH 5 HOOO 1 0 17 2 aood mar a BUZZER REQUEST TO EXIT DEVICE Connect readers and keypads 18 READER CONNECTION TERMIN
61. tion or Factory Default DHCP is done at Kantech The following steps should be followed only if a You want to configure the KT 400 with the KT Finder see page 32 b The KT 400 was communicating via the RS 232 port and you have installed VC 485 or USB 485 to communicate the RS 485 port c The KT 400 was communicating 485 or a USB 485 interface and you want to communicate directly with the serial RS 232 port d You are using a KT 400 from another site and there is no communication How to reset the KT 400 Ethernet Four Door Controller for Factory Default DHCP mode Before you start e Locate the reset button the two jumpers JP2 and the blue Heartbeat LED Ethernet cable must be connected to the corporate network The green LINK LED should lit and the yellow TXRX LED should be flashing blue Heartbeat LED should be flashing Remove JP2 and JP3 jumpers as described in Table 3 for Factory Default DHCP mode Press the reset button Check the blue Heartbeat LED heartbeat pattern Verify the IP address with the KT Finder see page 32 Put back JP2 and JP3 jumpers Configure the KT 400 with the KT Finder see page 32 Figure 13 KT 400 Factory Default Steps p ME uer ey 3 000 J I 001 28 DN2003 1202 v01 11 KT 400 Ethernet Four Door Controller Installation Manual KT 400 Ethernet Four Do
62. ty Note To set these priorities please adjust the Event Parameters found in EntraPass System Fire alarm and industrial supervision where risk of injury to persons or damage or destruction of property may be involved e Hold up or panic alarm e Burglar alarm e Watchman tour Guard tour Fire alarm supervision e Burglar alarm supervision e Industrial supervision where a risk of injury to persons or damage or destruction of property will not be involved If multiplex system signals are transmitted directly from the protected systems to the central supervising station and the loss of the channel prevents the receipt of signals from protective circuits beyond the fault the number of separate signals on a single channel shall be limited to 1000 Ethernet connections on the KT 400 are not to be used for off premise communication in UL 1076 installations For remote alarm monitoring use KT 400 in conjunction with KT NCC FCC amp IC Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations CE amp C Tick e EN50133 1 Alarm systems Access control systems for use in security applications system requirements e EN55022 Information technolog
63. unication between the KT 400 and RS 485 modules e 1 SPI for communication with SPI modules e 1 USB 2 0 Host Note You can connect a loop of KT 200 controllers on the RS 485 of the KT 400 if not mixed with other controllers Kantech KT 100 KT 300 and KT 400 Note The 10 100Base T ETH2 RS 485 COM2 and USB 2 0 Host communication ports are to be used ONLY on upcoming versions of the KT 400 controller IP Connectivity The KT 400 Ethernet Four Door Controller when used with EntraPass Special Edition or a Multi Site Gateway can report events gather its configuration through an IP connection over the LAN Local Area Network and over the Internet for a WAN Wide Area Network In this mode the 1st or local controller becomes a Master Controller and can poll up to 31 Kantech controller s The KT 400 Ethernet Four Door Controller is compatible with all the controllers Unlike the other controllers the KT 400 Ethernet Four Door Controller asynchronously polls the controllers KT 100 KT 200 KT 300 and communicates with the EntraPass Gateway only when necessary This significantly reduces the amount of bandwidth required to operate your security system on the network AES Encryption 128 Bit The 400 Ethernet Four Door Controller is extremely secure It uses 128 bit AES encryption to communicate with the Gateway which prevents any hacking from the internet and ensures secure communications when used over the internet on a wide are
64. ut You may only have one copy per license installed at any given time You may use the back up copy solely for archival purposes Except as expressly provided in this EULA You may not otherwise make copies of the SOFTWARE PRODUCT including the printed materials accompanying the SOFTWARE DESCRIPTION OF OTHER RIGHTS AND LIMITATIONS Limitations on Reverse Engineering Decompilation and Disassembly You may not reverse engineer decompile or disassemble the SOFTWARE PRODUCT except and only to the extent that such activity is expressly permitted by applicable law notwithstanding this limitation You may not make any changes or modifications to the Software without the written permission of an officer of KANTECH You may not remove any proprietary notices marks or labels from the Software Product You shall institute reasonable measures to ensure compliance with the terms and conditions of this EULA Separation of Components The SOFTWARE PRODUCT is licensed as a single product component parts may not be separated for use on more than one HARDWARE unit Single INTEGRATED PRODUCT If You acquired this SOFTWARE with HARDWARE then the SOFTWARE PRODUCT is licensed with the HARDWARE as a single integrated product In this case the SOFTWARE PRODUCT may only be used with the HARDWARE as set forth in this EULA Rental You may not rent lease or lend the SOFTWARE PRODUCT You may not make it available to others or post it on a server or web site
65. wing conditions shall also be programmed to be annunciated by the EntraPass software e access point is opened and closed Door closed normal condition permitted APAS release time has expired without the access point being opened Time out on access granted e the access point has remained open and the allowed APAS open time period has expired Door open too long DN2003 1202 v01 11 KT 400 Ethernet Four Door Controller Installation Manual DN2003 1202 01 11 43 44 0 2003 1202 v01 11 0290029124003 2012 Tyco International Ltd and its Respective Companies All Rights Reserved www kantech com DN2003 1202
66. y equipment radio disturbance characteristics 60950 1 Information technology equipment safety DN2003 1202 v01 11 400 Ethernet Four Door Controller Installation Manual e 61000 6 1 Electromagnetic Compatibility EMC Generic Standards Immunity for residential commercial and light industrial environments e 61000 6 2 Electromagnetic Compatibility EMC Generic Standards Immunity for industrial environments The KT 400 Ethernet Four Door Controller is also compliant with EN55022 2006 A1 2007 Class B EN50133 Compliance Notes and Requirements The KT 400 Ethernet Four Door Controller provides the following functions as per EN50133 1 Fig 1 and Section 4 1 e processing 1 power supply 2 e Self protection 3 e programmability 4 when using the EntraPass Version 4 01 and higher e access point control 5 e recognition 6 when used in conjunction with the compatible recognition modules access point interfaces e annunciation 8 when used in conjunction with the EntraPass Ver 4 01 and higher e communication with other systems 9 only when used in conjunction with the EntraPass Ver 4 01 and higher The KT 400 Ethernet Four Door Controller can be used in conjunction with user interfaces that support recognition classes 0 1 2 and 3 and it supports access class A or B depending on the desired installation of the access control System Environmental Class 2 Equipment Class Fixed IP Class