User Manual - CARDIFF Air Conditioning
Contents
1. x oM D Evaprotator fan A RE 4 ENC Condenser N8 NH Evaporator 6 1 COMPRESSOR 7 SINGLE WAY VALVE 2 HIGH PRESSURE SWITCH 8 EXPANSION VALVE 3 REVERSING VALVE 9 SINGLE WAY VALVE 4 LOW PRESSURE SWITCH 10 EXPANSION VALVE 5 PIN VALVE II DRY FILTER 6 OIL SEPARATOR 4 BODY DIMENSION 9Z 10Z 12Z 5 6 16Z 18Z 23Z 25Z 28Z 32Z 36Z Notes Unit fixed hole 4x 12 5 Unit sling hole 4x q 35 Unit electric control panel Unit power cable pass through 25 Unit signal wire holeg 16 Unit condensing water discharge pipe 1 10 Notas 1 Unit fixed hola 4x sp 12 5 2 Unit sling hola 4x 35 3 Unit electric control panel 4 Unit power cable pass through 25 5 Unit signal wire hole 16 6 Unit condensing water discharge pipe 1 42Z 48Z 55Z 62Z 72Z 88Z Notes vo 2750 2350 1800 1542 1195 5755 462 2100 307 5 615 13315 750 1 Unit fxed hole 4x p 12 5 2 Unit sling hole 4x q 60 1 Unit fxod hdo 4x q 125 2 Unit sing hola 4x 9 40 Model WII varian varea A 4700 4700 5200 B 650 650 800 C 3400 3400 3600 D 950 50 1009 E 2800 2800 3150 F 1640 1640 1640 G 2800 2750 2750 H 1700 1800 2100 M 33425 32885
2. I Peace of Mind The manufacturer operates a quality management system that conforms to international standard ISO 9001 Cardiff products have been chosen against worldwide competition for use in some of the most exclusive projects chosen because of their proven efficiency durability performance reliability and value G Easy service Quick release fasteners are provided on electrical and compressor panel H Quiet design Apartments are provided on electrical and compressor section low noise L1 Components or assembly descriptions A Quiet operation The package Rooftop series are basic constructed and engineered with noise reduction as a first consideration low noise mounted fans are used 15mm wave type acoustic Insulation for compressor section and compressors are mounted on vibration isolators B Low Cost Installation Units are factory assembled and pre charged with a single point electrical connection On arrival to the job site they are ready to be lifted to their operating position through the lifting supports available on the units C Capacities to Fit There is a large production line of packaged units with capacities ranging from 3 0 to 53 0 for 50 Hz refrigeration tons at nominal conditions D Casing Heavy grade steel casing with polyester epoxy powder electrostatic oven baked paint of coating finish designed for outdoor Installation with 10mm Insulation for evaporator section only All units are
3. 3 Check that all fan motors are free running 4 Check that the thermostat is correctly wired to the unit and is set at the desired temperature 5 Check that the air filters have been correctly installed if fitted 6 Check air diffuser dampers are open if appropriate START UP PROCEDURE Use the supplied Commissioning Sheet to help you complete the following procedure 1 After the four hour delay period has expired switch on the unit System 1 s compressor will start straight away System 2 s compressor will start six minutes later due to the built in delay timer 2 Check the supply voltage between each phase and neutral 3 Compressors fitted are directional Check for correct rotation If rotation is incorrect the compressor will not pump be noisy and will draw minimal current To correct motor rotation change the phasing at the main power terminal 4 Measure the current draw on each phase to the compressor motors and measure the current draw of each fan motor Check all readings against the specified values in the wiring diagram 5 Fit gauges and measure the suction and discharge pressures of both refrigeration circuits 6 Check that the outdoor air fan motors are running smoothly 7 Test the operation of the reversing valve by running the unit in both the heating and cooling mode 8 Check the indoor unit s fan belt tension after 20 mins of operation and adjust if necessary refer Commissioning Sheet 9 Check the supply
4. 34385 L 615 723 723 J 609 773 773 N 462 400 400 5 INSTALLATION CONTROL OPERATION AND AINTENANCE Read all instructions before proceeding with the installation and start up PREFACE 1 UNPACKING Retain packing materials until the unit is operated and found to be in good condition If the unit shows external or internal damage or does not operate properly contact the transportation company and file a damage claim 2 AFTER SALES SUPPORT CARDIFF is committed to customer service both during and after the sale If you have questions concerning the operation of your unit or the information of this booklet contact our Sales Department If your units fail to operate properly or if you have questions concerning spare parts or Service Contact contact our Sales Department SECTION I SAFETY These instructions are primarily intended to assist qualified individuals experienced in the proper installation of heating and or air conditioning appliances Some local codes require licensed installation service personnel for this type equipment All installations must be in accordance with these instructions and with all applicable national and local codes and standards We recommend that you read this instruction manual carefully before use to gain full advantage of the functions of the unit and to avoid malfunction due to mishandling Read these instructions thoroughly before starting the installation F
5. air conditioner applications e g offices shops motels fast food outlets restaurants petrol stations open plan office and work spaces supermarkets shopping malls and auditoriums Units are suited to high static pressure applications where large volume spaces are to be air conditioned Long pipe and duct runs are possible enabling greater installation flexibility This range of units has been developed to meet the needs of typical applications Should you have special requirements such as higher air flows or greater sensible duty units contact your nearest Cardiff representative Cardiff engineers have extensive experience in designing air conditioning equipment for specific applications Typical installation 4 Main Descriptions L1 Unit description A Efficient These reverse cycle heat pump air conditioners provide one of the most efficient forms of heating you can invest in For every 1 kW of power consumed up to 3 kW of heat is generated Each outdoor unit incorporates high efficiency scroll compressors Heat exchange coils use inner grooved tube for better heat transfer B Performance These systems have been designed and tested to perform in ambient conditions as low as 5 C and as high as 45 C Belt drive fan motors are used to match the supply air requirements The smaller units have 3 speed direct drive fans for adjusting air flows C Durable Our packaged systems are built tough to withstand all weathers The
6. air flow at each outlet 10 Check the tightness of all electrical connections and sign the check label 11 Touch up any outdoor unit paintwork damage to prevent corrosion N CAUTION THE UNIT IS EQUIPPED WITH CRANKCASE HEATERS ALLOW 24 HOURS PRIOR TO CONTINUING START UP PROCEDURES TO ALLOW FOR HEATING OF THE REFRIGERANT COMPRESSOR CRANKCASE FAILURE TO COMPLY MAY RESULT IN DAMAGE AND COULD CASUE PREMATURE OF THE SYSTEM THIS WARNING SHOULD BE FOLLOWED AT INITIAL START UP AND ANY TIME THE POWER HAS BEEN REMOVED FOR 12 HOURS OR LONGER 17 START UP CHECKLIST amp COMMISSI ON IN GDATA Remove and hand to AC unit owner PRELIMINARY INFORMATION MODEL No SERIAL No DATE TECHNICIAN PRE START UP Insert checkmark in box as each item is completed 1 VERIFY THAT ALL PACKING MATERIALS HAVE BEEN REMOVED FROM UNIT 2 REMOVE ALL SHIPPING HOLDDOWN BOLTS AND BRACKETS AS PER INSTALLATION INSTRUCTIONS 3 CHECK ALL ELECTRICAL CONNECTIONS AND TERMINALS FOR TIGHTNESS 4 CHECK THAT CONDENSATE CONNECTION IS INSTALLED AS PER 3 INSTALLATION INSTRUCTIONS 5 CHECK THAT INDOOR AIR FILTER IS CLEAN AND IN PLACE 6 VERIFY THAT UNIT INSTALLATION IS LEVEL 7 CHECK FANS FOR ALIGNMENT AND NOISE Record the following data after at least 20 minutes running time COMPRESSORS No 1 No 2
7. BR PR 0622 EN Cardiff 2 B wi M Air Conditioning C bud non RoorropP PACKAGED UNITS User Manual C Note For your reference only CARDIFF reserves the rights to change the COMPANY WITH QUALITY SYSTEM ata without previous notice Please kindly contact Cardiff in time if you ISO 9001 2000 have special requirements BRIEF INTRODUCTION AND FEATURES 1 General Introduction 1 CARDIFF WRFZ series and WFZ series units are single packaged units which are factory assembled tested and shipped complete with compressor evaporator and condenser coils fans and controls and these packages are designed for outdoor installation mainly and indoor installation as optional And they may be used for cooling only or heat pump and efficient both when heating and cooling The units are ideal for residential commercial and industrial applications and are available in nominal tonnage from 3 0 to 53 0 tons for 50HZ Quality design and construction make bright air cooled rooftop package units with hermetic scroll compressors the preferred applications and easy installation and maintenance Operation range of outdoor temp is from 10 C to 43 C 2 Cardiff rooftop units APPLICATIONS Rooftop packaged systems are unobtrusive quiet and designed to provide year round comfort warming in Winter and cooling in Summer Cardiff wide product range offers a unit of performance capacity to suit small to large packaged
8. Suction Pressure KPa KPa Suction Line Temperature C C Discharge Pressure KPa KPa Liquid Line Temperature C C Superheat K K Subcooling K K Compressor Amps L1 A A Compressor Amps L2 for 3 phase A A Compressor Amps L3 for 3 phase A A Indoor fan Amps L1 A Indoor fan Amps L2 A Indoor fan Amps L3 A FANS No 1 No 2 Outdoor fan Amps L1 A A Outdoor fan Amps L2 A A Outdoor fan Amps L3 A A Indoor coil Return Temperature C DB C WB Indoor coil Supply Temperature C DB C WB Outdoor air Temperature C DB C WB Length of liquid line m m Length of suction line m m Oil level 1 l Refrigerant quantity charged kg kg Supply voltage V V Actual voltage V V 18 MAINTENANCE SECTION IV MAINTAINENCE To ensure continuing high performance and to minimize the possibility of premature equipment failure periodic maintenance must be performed on the air conditioning equipment The units should be inspected at least once each year by a qualified service person The minimum maintenance requirements for this equipment are as follows MAINTENANCE TIME SCHEDULE Monthly 4 Check for excessive noise and vibration and correct as necessary 1 Check air filters Replace throwaway type filters when they become clogged with dust and lint or clean cleanable type filters monthly 3 Check suction and discharge operating pressures 5 Check fan and motor bearings and lubricate or replace as n
9. class B electrical insulation D Belt Drive Evaporator Fan Fans are of the forward curved centrifugal double inlet double width DIDW type that are designed for maximum efficiency for uniform air distribution V belt driven with variable pitch pulley as optional All fans are statically and dynamically balanced to ensure quiet operation and smooth performance J Evaporator Fan Motors Motors are of the totally enclosed induction type with fan motor assembly placed on a floating base with a flexible connection at the fan casing interface The base itself is mounted on rubber in sheer vibration isolators to eliminate noise and vibration transmission to buildings All fan motors of direct driven are of the 3 speed type 4 highly efficient induction type motors totally enclosed air cooled squirrel cage type internal thermal current protected and with class B insulation Fan motors with V belt driven type are of 1 speed type K Filters All Models are provided with 8mm thickness aluminum frame filter as standard features Other filters are available upon request L Drain Pan All units are provided with a drain pan having drain connection from one side The drain pan is insulated on the underside to prevent condensation M Insulation All units are internally lined with 10mm thermal insulation for coil and fan section evaporator side only N Easy Installation The package Rooftop has a c
10. e handled with a fork truck Exercise care when moving the unit Rig the unit by attaching chain or cable slings to the holes provided in lifting lugs Spreaders MUST be used across the top of the unit Ensure the lifting equipment is adequate for the load Keep the unit in an upright position at all times The rigging must be located outside the units center of gravity Lifting plates may be removed after installation Typical lifting arrangement 15 N CAUTION ALL ACCESS PANELS MUST BE SECURELY IN PLACE WHEN RIGGING AND HOISTING MOUNTING The unit should be fastened to a firm flat horizontal base plinth using the holes supplied in the mounting rails When the unit is being installed on a roof it is recommended that the unit is installed on a substantial structure with vibration isolating springs beneath the unit These springs are not supplied with the unit Three channels are provided under the base for spring mounts or bolting down Flexible duct connections are recommended between the supply and return ducts and the unit SECTION IH OPERATION CHECK TESTS 1 Leave the on off switch in the off position and close the mains isolating switch A four hour delay period is required to allow the crankcase heaters to drive any liquid refrigerant out of the compressor oil 2 Check that the shipping blocks beneath each compressor have been removed and that each compressor is secure on its mounts
11. ecessary 2 Check condensate drain for free drainage 4 Replace indoor air filters if fitted 6 Check for insulation and duct damage and repair as necessary 3 Check compressor compartment for oil stains indicating refrigerant leaks 5 Check condensate drain for free drainage 7 Remove lint and dust accumulation from outdoor coil fins Three Monthly or every 1200 hrs of operation 8 Touch up any paintwork damage to prevent corrosion Check the indoor unit s fan belt tension and adjust if necessary Yearly Inspect outdoor coil Clean when necessary Six Monthly 1 Check all refrigerant piping for chafing and vibration Ensure that fan blades are clean and adequately balanced 1 Check the tightness of electrical connections 2 Check the operation of electric heaters if fitted Check refrigerant charge by measurement of superheat and sub cooling where necessary adjust charge and TX valve to achieve optimum performance 2 Check the tightness of all fans motor mountings pulleys and belt tension 3 Check air supply at all diffusers Check the tightness of electrical connections 19
12. ed on minimizing the length of the supply ducts Consideration should also be given to availability service access noise and shade The unit installation shall avoid areas where condensate drainage may cause problems CLEARANCES The units require certain clearances for proper operation and service Installer must make provisions for adequate ventilation air normally 2000mm s spaces all around the units It s required to place a anti wind rain hood 2000mm above the unit A CAUTION DO NOT PERMIT OVERHANGING STRUCTURES OR SHRUBS TO OBSTRUCT CONDENSER AIR DISCHARGE OUTLET AIR INLET OR VENT OUTLETS AIR FILTER REQUIREMENT A suitable air filter must be installed in the unit This unit is supplied with air filters Air filter s must be installed ahead of the evaporator coil of this unit A CAUTION NEVER OPERATE UNIT WITHOUT A FILTER A FAILURE TO FOLLOW THIS WARNING COULD RESULT IN A PERSONAL INJURY OR DEATH 2 UNIT INSTALLATION GROUND LEVEL If installing the unit at ground level provide a concrete mounting pad separate from the building foundation The pad must be level to ensure proper condensate disposal and strong enough to support the unit s weight UNCONDITIONED SPACES All ductwork passing through unconditioned spaces must be properly insulated to minimize duct losses and prevent condensation Refer to local codes for any insulation material requirements RIGGING AND HOISTING This unit is not designed to b
13. ir durable construction ensures a long life and excellent return on your investment The outdoor air coils aluminum fins are epoxy coated for extra protection in corrosive environments e g salt laden sea air Cabinets are constructed from high grade steel polyester powder coated for all weather protection External fasteners are stainless steel Corrosion resistant drain trays are also included D Insulation Indoor air sections are generously insulated to reduce condensation and contain noise E Safety The refrigeration systems includes a number of protection facilities including HP and LP switches anti rapid cycle timers circuit breaker control circuits electronic de ice switch and 24 V control F Economy Some models feature the flexibility and economy of two stage operation Compressors are progressively switched on only as they are needed This has the added advantage of lowering start up current G Economizer Option If the outdoor air heat content or temperature is below that of the return air a fresh air damper opens and the return air damper closes to provide the first stage of cooling Operating costs are reduced as the compressor s will only operate to provide more cooling if it is required H Fresh Air Introduction An optional fresh air damper is available for most models For applications using high proportions of fresh air 50 a hot gas bypass and HP fan speed controller are recommended and are available as options
14. lay for each motor Power factor correction capacitor Auto or manual provision for pump down operation of each compressor stop Building automation system interface Interfacing With other building management systems can be Achieved by an optional card which can communicate with other devices using the serial communication port Voltage monitor controller phase failure relay for monitoring the main incoming power supply for the unit which provides protection from single phasing under voltage phase voltage imbalance and phase nonsequence C Refrigeration options Heat pump package unit with 4 way reversing valve suction accumulator is a standard feature in heat pump option Pressure gauges for each refrigeration circuit high low pressure gauges New refrigerant application R410a and R407c Hot gas bypass where low local situation occurs and where it is necessary avoid low suction pressure and compressor cycling Extra refrigerant accessories such as suction accumulators for cooling units only refrigerant liquid receivers oilseparators etc Solenoid valve for heat pump mode High and low pressure controller for model 9Z and up to model 190Z 2 REFRIGERANT PIPING DIAGRAM Condensing fan ae t
15. num coils only 4 25mm 1 or SOmm 2 thick flat filter 5 Economizer option with fresh return and exhaust air dampers with cowl If this option is installed in the unit the unit has the ability to work with free cooling or free heating mode allowing it to exploit the external environmental condition as much as possible since it avoids turning on the heaters and the compressors This function can be achieved by controlling the opening closing of the external air damper With reference to the difference between the outdoor air temperature std enthalpy and the indoor air temperature std enthalpy 6 High Static condenser fan option will also required a sealed drain condensing section 7 Upgraded Evaporator Fan Motor Drives B Electrical options 1 Power circuit breaker for each motor 2 Main power molded case circuit breaker for the whole unit can also be available with an external handle as an option 3 Low ambient control The refrigeration systems in all unit are inherently designed to operate efficiently without extra controls or modifications To permit the unit to operate In low ambient condition a head pressure control can be Installed either by 10 ON OFF Condenser fans sequencing for models with 2 condenser fans 2 specd of the condenser fan motor Earth leakage relay for each compressor Earth leakage relay for the whole unit External overload re
16. ollow all precautions and warnings contained within these instructions and on the unit 1 SAFETY CONSIDERATIONS The unit is designed to provide safe and reliable service when operating within design specifications To avoid injury to personnel and damage to equipment or property when operating the equipment the following safe practices should be observed as a minimum Check the unit weight to be sure the lifting equipment is adequate Disconnect power to the unit before working on it Do not remove access panels or doors until fans have completely stopped Do not enter an enclosed fan cabinet or into the unit while the fan is running Protect materials when welding or flame cutting Use suitable cloth to contain sparks Have a fire extinguisher at hand and ready for immediate use 2 WARNING and CAUTION The precautions described below are WARNING and CAUTION These are very important precautions concerning safety Be sure to observe all of them without fail A WARNING The matters with possibilities leading to serious consequences such as death or serious injury due to erroneous handling A CAUTION These are the matters with possibilities leading to injury or material damage due to erroneous handling including probabilities leading to serious consequences in some cases Installation and servicing of air conditioning equipment can be hazardous due to system pressure and electrical components Only trained and qualified service per
17. ompact design It is supplied as a complete package ready for operation with no extra controls or other items to be installed The units have a single power point entry with simple connections All units are designed to ensure maximum compliance with international standards Quick start up is assured once installation is complete as each rooftop unit is manufactured in an ISO9001 listed facility to guarantee quality All units are tested at the factory to provide reliable start up 5 Standard Features A Standard features 1 Easily accessible system components 2 Ample space for easy access to power and control panels 3 Heavy duty mounting chassis for the whole unit with lifting holes 4 Anti vibration mounting compressor rubber type 5 Weather proof polyester epoxy powder electrostatic paint oven baked finish for sheet metal and base frame 6 Allunits are shipped out from factory tested and protecting devices seated against client requirement 7 S8mm Nylon filer as standard for Returning air inlet 8 Single skin evaporator side with 10mm thermal installation 9 Condenser coil with treated blue fins 10 Quick release fasteners to be provided on electrical and compressor apartment cabinet 5 B Electrical features 1 Control and power panels include the direct on line starting contactors for the compressors and condenser fan motor Internal thermal motor protector for condenser and evapora
18. provided with a 8mm thickness aluminum frame filter that slides out or easy cleaning or replacement E Compressor The compressor used is hermetic refrigerant gas cooled with Internal thermal protection In each phase scroll type The terminal boxes are rain tight starting is direct on line With high efficiency low sound so as to match all other Cardiff products reliability and efficiency F Evaporator and Condenser Coils The evaporator and condenser coils are designed to deliver their respective duties at optimum performance at all design conditions Coils are manufactured from seamless copper tubes mechanically expanded into aluminum fins All coils are tested at 30kg cm 450 Psi air pressure under water to avoid leakage They also undergo dry chemical cleaning after manufacturing for optimum system cleanness G Direct Driven Condenser Axial Fans All condenser fans are of the Axial type which are directly mounted on the motor shaft All fans are selected for optimum efficiency and for maximum sound power reduction Fan blades are made for maximum corrosion resistance and are statically and dynamically balanced before Installation Cardiff try its bests to ensure the low noise operation with high efficiency All condenser fans are equipped with wire guards H Condenser Fan Motor All fans motors are of totally enclosed air cooled squirrel cage type Internal thermal current overload protected with
19. rge Adjustment As stated previously the system is pre charged If further charge is required to be added this can be done by CAREFULLY drawing LIQUID refrigerant only through the compressor suction pipe valve ELECTRICAL All electrical work must be carried out by a qualified and licensed electrician The installation must comply with the current relevant standards wiring rules and local authority requirements Wire sizing is the responsibility of the installer as it depends on the conditions and regulations applicable to each installation site Refer to the electrical drawing and specification of the unit for the electrical data The electrical installation requirements are generally as follows The air conditioning unit shall be supplied directly from a distribution board through a mains lockable isolating switch Pre punched holes have been provided in the unit casing for the isolating switch Do not drill into the cabinet as pipes may be located behind REQUIREMENTS AND CODES The unit should be installed in accordance with all national and local codes and regulations which govern the installation of this type of equipment In lieu of local codes the equipment should be installed in accordance with National Electric Code and in accordance with the recommendations made by the National Board of Fire Underwriters UNIT LOCATION The electric unit is designed only for outdoor installations Choosing the location of the unit should be bas
20. sonnel should install repair or service air conditioning equipment Untrained personnel can perform basic maintenance functions of cleaning coils and filters and replacing filters All other operations should be performed by trained service personnel When working on air conditioning equipment observe precautions in the literature tags and labels attached to the unit and other safety precautions that may apply 3 ADDITIONAL WARNINGS In addition to the specific warnings listed on the previous page the following general warnings apply to your unit 13 Performance of installation operation or maintenance procedures other than those described in this manual may result in a hazardous situation and may void the manufacturer s warranty Transport the unit with care Sudden jolts or drops can damage the refrigeration lines Observe all warning labels Never remove warning labels Never operate damaged or leaking equipment Always turn off the unit and disconnect the power cord from the power source before performing any service or maintenance procedures or before moving the unit Never operate equipment with damaged power cords Refer service and repairs to a qualified technician Do not overcharge with refrigerant SECTION II INSTALLATION 1 INSTALLATION REQUIREMENTS EQUIPMENT APPLICATION Before beginning the installation verify that the unit model is correct for the job The unit model number is printed on the data label Cha
21. tor fan motor Compressor internal thermal protection Anti recycling protection for compressors time delay through microprocessor Crank case heater for each compressor Control circuit breaker 24Volt as control voltage Microprocessor controller for model 120Z and above with the following main functions a Compressor lead lag operation to ensure longer life for the compressors and equal running hours between compressors b External remote ON OFF button for remote operation of the unit using external ON OFF switch or connection to building management system c Volt free terminals available for general alarm indication signal to remote monitoring station One power supply input 10 High and low pressure safety switches capsule type factory Pre set from all models C Refrigeration features Hermetic scroll suction gas cooled compressor motor Filter drier disposable type Charging points pin valve Service valve on liquid line Thermostatic expansion valve 6 Fully charged unit with Freon R22 7 Solenoid Valve 8 Oil equalizing lines installed between parallel installed compressors 6 Optional Features A Construction options 1 Metal mesh on condenser section 2 Optional Supply Return Air Configurations optional bottom supply and return type 3 Evaporator with treated Anti corrosion protection for coils Blue fins for copper alumi