SHORT USER MANUAL for operation of

image

Contents

1. burner s grate 3 8 Description of the attached liquid crystal thermosticker indicating the requirement for ash cleaning the hot water boiler s heat exchanger also the burner itself as well as the exhaust gases duct Detailed information of the reversible thermosticker as well as the irreversible thermosticker is given in the full version of the pellet burner user manual The liquid crystal thermosticker is utilized to measure the temperature of the burner in near vicinity of its application in characteristic points The thermosticker indication gives information for the requirement of cleaning the system elements As the indicated temperature rises the ash cleaning is recommended to be performed in the following way e Cleaning the ash residue off the burner s grate e If the indicated temperature is still higher than nominal range it is recommended to clean thoroughly the ash residue accumulated on the heat exchanger of the consumer internal surfaces e Ifthe indicated temperature is still higher than nominal operating range it is recommended to clean the ash residue off the exhaust gases duct as well as the chimney The chimney s draught should be checked as well p 11 12 Inreversible thermosticker Reversible liquid Ss Figure 3 11 Side view of crystal i the liquid crystal thermosticker thermostickers Figure 3 12 The reversible thermosticker is used to indicate the operating temperature in a specific
2. region of the pellet burner in near vicinity if its application The example figure shows operating condition of increased local temperature in the range of 80 85 C the thermosticker s nominal condition the local temperature has not been raised up above its activation temperature level of 104 C The indication of the reversible thermostricker should be checked on A regularly The detachment or any damages of the thermostickers violates the pellet burner s warranty conditions 3 9 Restarting the pellet burner s operation The pellet burner should be restarted when it is in alarm model The restarting 1s performed by sequential powering off and back powering on the automatic short circuit breaker of the heat consumer s power supply module It is recommended to clean the ash residue from the burner s grate prior restarting its operation p 12 12
3. supply plug Figure 2 3 Section view of the pellet burner s main module components G ATTENTION the flexible hose which connects the transport auger and the main module should be stretched in order to prevent any pellet particles blockage Transparent window for operating mode monitoring Wood pellets delivery pipe to the combustion chamber and back fire temperature sensor burner s main module A Combustion chamber s A grate Photosensor Figure 2 4 Side view of the burner s main module p 4 12 2 1 Interface panel of the automatic pellet burner of series GP POWER indicator lamp Thermal capacity control potentiometer START indicator lamp Figure 2 5 Interface panel with indicator lamps and control elements of the automatic pellet burner a Elements of the interface panel and their function e Indicator lamp POWER indicates the presence of power supply in the burner s main module e Indicator lamp START indicates the presence of START ON signal of the pellet burner e Potentiometer controls the thermal capacity of the pellet burner 2 2 Color scale for manual synchronization of the air flow rate and the thermal capacity of the burner Lever for manual positioning of the air flow rate control flap Figure 2 6 Color scale for K synchronization of the air flow rate for combustion according to the ther
4. system e Switch START of the heat consumer controlled module not part of the burner s installation kit Figure 3 8 Do NOT in any case switch off the burner by turning off its power supply p 9 12 3 7 Cleaning and maintaining the pellet burner At cleaning the pellet burner s grate it 1s required to take put the grate from the main module s combustion chamber as it is shown on the following figure Combustion chamber of the burner s main module Inclined grate of the burner s main module Burner s grate Figure 3 9 Side view of the pellet burner s main module and the grate is taken out of its combustion chamber NOTE the burner s grate should be taken out only after it is cooled down to safe temperature levels Use self protection and appropriate instruments for example working gloves and pliers in order to take out the grate At cleaning the burner s grate pay attention on the total cleaning of the grates air distributing holes The putting of the burner s grate is performed in two steps as shown on the following figure p 10 12 ray l 8 i e ojo y i mih 1 initial grate putting i fin i a step i KS i Vv 2 Sliding under the grate NR and its final positioning a p N a a a a geese a Se aanesaw aes X fe SS CC Specialized feets of the NL r burner s grate iim Figure 3 10 Cross section of the burner showing the steps of positioning the
5. SHORT USER MANUAL for operation of automatic pellet burner of series GP cs http www greenecotherm eu p cccceccccccecccecscsecscsesessssesersesesecsesssescesosesresesessesoscrcososcccococcsoceccosecccccscscssocoocococoodhccccccococcscococcosococcocococcocococcocococcococoosococsccococcocococcococcecosoccocosoccccosocoocococcocococcocococcocosrecocoscocococcosococccosoccosocoscososoccosoccososoccocosocososcecoseccesossssocosocoocococcecococcocococcocococcococcocococoscococcccococcosococcosocoococococcosocoocososoccococoococoocosocoocococoocococoocosoocosocogy Address Bulgaria Haskovo 6300 Saedinenie 67 blvd i Phone 4359 800 15145 0 j Fax 359 38 603070 l e mail greenecotherm erato bg tst B Thank You for buying our product automatic pellet burner of series GP NOTE in this manual is used the symbol GP for the entire range of pellet burner which includes the models GP25 cs and GP32 cs The automatic pellet burners of series GP cs are modification of the well known pellet burners of series GP but they are equipped with color synchronization scale used to synchronize the thermal capacity of the burner and the air flow rate in order to achieve optimal operating parameters in wide operating regimes of the burner In the manual however will be used a common symbol GP This manual contains only basic information for the operation of the pellet burner More detai
6. apacity adjustment The adjustment of the pellet burner thermal capacity is performed by the adjustment of the position of the thermal capacity control potentiometer parameter P2 see the burner s manual NOTE e Jn the color scale blue region the burner operates at minimal thermal capacity e Jn the color scale green and the yellow region the pellet burner operates in the region of nominal thermal capacity e Jn the color scale red region the pellet burner operates at maximal thermal capacity p 8 12 A criteria for efficient operation of the pellet burner is the color of the flame it should be straw yellow and transparent to some extend 3 5 Variation of the pellet burner thermal capacity Ma Figure 3 6 Changing the thermal capacity potentiometer position OUTPUT POWER Turning the potentiometer clockwise increases the pellet burner thermal capacity Turning the potentiometer anti clockwise decreases the pellet burner thermal capacity Manually adjust the air flow rate control flap into thermal capacity potentiometer corresponding position Figure 3 7 Adjustment of the air flow rate in correspondence with the position of the thermal capacity potentiometer 3 6 Stopping the pellet burner operation The stopping of the burner s operation should be made by switching OFF the following e The operating thermostat of the heat consumer unit e The room thermostat if attached to the
7. led information for the installation and operation of the unit is given in its complete user manual which could be found on the producer s web site as well SHORT USER MANUAL for operation of the automatic pellet burner of series GP cs Edition 03 05 2012 10 40 1 Description of the automatic pellet burner GP is automatic pellet burner which utilizes wood pellets The burner is designed to be installed on already operating heating boilers or other equipment The installed burner operates on wood pellets and other biomass fuel The color synchronized flap allows easy adjustment of the thermal capacity and the required air flow rate by the end user The pellet burner of series GP could utilize the following fuels e Wood pellet with diameter 6 and 8 class ENplus Al according to standard ENplus or category A AB B according to methodology developed and applied by the unit producer company e Pre dried pits from cherries for example e Fuel mixture pellets and pits for example mixture ratio could be 50 50 2 Description of the burner Pellet hopper BP Figure 2 1 Correct position of the fuel transport auger inclination of 45 Figure 2 2 Incorrect position of the fuel transport auger the inclination angle is not 45 The fuel hopper of the figures is used for illustrative purposes only it s not a module of the pellet burner s kit p 3 12 Fuel transport power
8. mal capacity of the pellet burner The position of the lever should correspond with the position of the A thermal capacity potentiometer in order to achieve efficient combustion process and optimal operation of the unit p 5 12 3 Pellet burner operation and maintenance In the following text are given only the basic requirements for reliable and A efficient operation of the pellet burner 3 1 Basic requirements for operation of the automatic pellet burner e At operation the pellet burner should be checked on regular basis by the end user or the system maintenance staff e It is not recommended to increase the thermal capacity of the burner above its nominal one e The combustion process ash residue should be collected in fireproof containers with lids and after cooling the mineral mass should be deposited at appropriate sites 3 2 Switching ON the burner The power supply of the burner is provided by the power supply module of the heat consumer appliance having attached the burner In case the burner has been in operating mode and the power supply has been interrupted at power supply renewal the burner start or continues its operation automatically Switching ON the control module in most of the cases this is the hot water boiler s operating thermostat Figure 3 1 Switching ON the hot water boiler s operating thermostat The showed control elements are used for illustrative purposes only and do not belo
9. ng to the pellet burner s installation kit The room thermostat should be switched ON as well if such module is connected to the system verify that the burner has the start signal NOTE At the initial start up process of the pellet burner the fuel transport auger should be filled with pellets This empty auger s filling up process has duration of approximately 15 20 minutes In order to fill up the auger one should plug the auger power supply into common power supplied electrical plug and wait until the pellets start to fall out of the exit pipe of the auger After the p 6 12 auger has been filled up its power supply plug should be connected into the burner s main module socket in order to be operated Figure 3 2 Manual power supply of the auger to common power supply socket ATTENTION in case the transport as auger power supply is not connected in the main module s power socket the burner s m control module goes into alarm mode which is indicated with permanent lighting of the yellow and the green LEDs After the auger s power supply has been plugged into burner s socket Figure 3 3 Manual plugging of the transport auger power supply into the burner s socket ATTENTION Jt is not A recommended to position the thermal capacity potentiometer into the color scale red region it is possible to operate the burner at thermal capacity exceeding the nominal one of the burner The pellet burne
10. r operation in the thermal capacity potentiometer red region is allowed for short period of time when the heat consumer requires increased thermal capacity or when the available fuel has calorific value less than the nominal fuel Figure 3 4 Not recommended adjustment of the pellet burner thermal capacity A If the photosensor does not sense the presence of the combustion process the ignition algorithm process is activated again In case of ignition failure the reasons could be e Absence of fuel in the transport auger p 7 12 e Presence of ash residue also some slagging on the burner s grate e Dirty photosensor clean the photosensor from the deposited tar and ash particles When the burner operates and there is stable combustion the red LED 1s light permanently while the green and the yellow LEDs are blinking serially Combustion process active indication the red LED is lit up Figure 3 5 Stable combustion process and its indication the red light emitting diode LED is lighted 3 3 Description of the LEDs installed on the pellet burner control board The green and the yellow LEDs are blinking one after another and indicate certain operating modes and messages which are used to estimate the pellet burner status The number of the blinking of the green and the yellow LEDs indicate the adjustment of the burner For mode information refer to burner s user manual 3 4 Pellet burner thermal c