Home

YL— 8 Series Intelligent Temperature Controller (ITC) ITC User

image

Contents

1. 3 D Basic function 6 Kinds of 5 External interval alarm External alarm Lower Limit 12 A With alarm removal function 2 3 5 12 13 15 Alarms Settings Standby alarm Factory Initial setting A Absolute value 13 D With alarm removal function 12 D Offset value Standby alarm 15 External alarm With alarm removal function Standby alarm Preset minimum value based on transmitters Factory Initial setting Preset max value based on transmitters K1 0 999 9 C 1 Rly Output contacts signals drive AC contactor coil or DC12V pulse voltage drive SSR Output Control l l 2 1 5V Output 0 5 V continuous voltage drive Depends on the 18 OUT Signals voltage regulating module control mode 3 0 5V Output 4 20 mA continuous current driver voltage regulating module 1999 epee ae Applicable when input linear signals current or ma nee Input Full Value voltage etc Factory Initial setting 0 5000 0 3 Decimal Points Only for linear signal Factory Initial setting 4 Wire Connection Map 1 Special Notes 1 Thermal couples input use compensating wire with corresponding codes 2 Thermal resistor input use three identical compensating wires with low resistant 3 Signal input wires should avoid magnetic interference from power lines electronic applicants 2 Wire Connection Layout 1 YL 8A 2 YL 8B 3 YL 8D 4 YL 8E E y i E t gt r pry A atah gt r ary o LP a
2. S N N 17 1 1 B R Wer 2 7 AAR Cu50 P 100 3 ttt S 0 10MA 4 20mA 0 5V 1 5V EH BAR R 2h Ph A250V 3A Hh E Tt fe BS S BkyY amp He12VDC 40mA WH He H AHS I 325 HYWi4 20mA 0 10mAT HH HB SHSHBHWRRE U 32242 A HRO 5VDC 1 5VDCHT EH IRA 7H Fh Ae 1 Ambiance requirements for this ITC pressure 86 105KPa temperature 0 50 C Relative humidity 45 85 RH 2 Do not operate ITCs right after dramatic ambiance temperature changes such as moving from cold outdoor to warm indoor 3 Do not operate ITC in humid salty and dusty surroundings or near combustible and corrosive materials such as gasoline chemicals metal powders 4 Do not operate ITC on a tremble and unstable structure 5 When placing multiple ITCs in the same location keep a distance of 25mm horizontally and 30mm vertically between ITCs Page 5
3. i fo rO OUT i gt 4 l 336 gt 1K Imn t 610 6 6 93 I Fag Kia Page 4 5 ITC Series Number Descriptions STYILONG WH Please verify the products you received with your orders series number model specs as follows ITC product series number has 10 digits such as YL O7AR 12 Each digit shows the following information Digit Possible Values Descriptions Ist 2nd YL ITC Model a4 Separator 4th Sth 08 ITC Series 6th Ato F Product dimension and specs See the table below for its W wide H height L length M N a b for each values of A to F R Relay output 250V 3A S Impulse voltage output for SSR 12VCD 40mA I Current output 4 20mA 0 10mA U Voltage output 0 SVDC 1 5 VDC 1 Thermal Couples K K1 J J1 E EI S N N1 T T1 B R Wer 2 Thermal Resistor Cu50 PT100 3 Linear signals 0 10mA 0 20mA 4 20mA 0 5V 1 5V Ss R S I U gm i Separator gth 1 2 3 Input signals 10 1 2 Secondary Controls 1 A1 One channel alarm control 2 A1 A2 two independent alarm channels any configuration combinations YL 8 0 0 00 KENS IM Fe FH Fil W H L Ais C BED CMD 4ED 0 8 0 8 A 92 92 0 6 0 8 48 91 45 92 0 7 0 7 T2 72 68 68 0 6 0 6 48 48 45 45 45 45 A ITC Operation Notes 4A ReMi i 1 Al R HIRE MH 2 Al A2 Bete MISH WA kaz JEAX MARS CREAS MA Bs Ts 7A FSB Ky K I JR Jl E E l
4. CHEE HA 4 STYILONG TAME YL 80 Series Intelligent Temperature Controller ITC ITC User Guide Please read carefully this entire User Guide before operating ITC Keep this guide for future references 1 Product Descriptions The YL 8 Series is designed and manufactured strictly based on European CE standards and has gone through five rigorous tests including testing in extreme temperatures 20 C to 75 C testing in various work loads and conditions and testing using specialized instruments These tests are designed to ensure the ITC is accurate reliable and durable in various applications under normal and special working conditions YL 8 Series employs advanced expert fuzzy technology and Dual Control Logics Its built in auto calibration intelligence ensures that ITC s performance is accurate reliable and durable and can track lock revise and react quickly to temperature changes The built in auto calibration intelligence is particularly useful for special temperature control applications e g operating multiple equipments with different temperature requirements each and the resulted heat interference or having specific requirements on temperature control related to factors such as heating and cooling capacity and ambiance temperatures In these special applications users can easily and quickly obtain a custom set of P I D values for their special applications As a result YL 8 Series ITC can be used in a wide range of ap
5. ad Resistance Max 500Q Voltage Load 12 kinds of upper lower limit alarm on deviation and absolute level are free combination Relay 250VAC 3A Resistive 250VAC 1A Sensing Cos 0 4 80 260VAC 50 60Hz lt 5W gt 10MQ Testing Condition 500VDC Outputting current or non contactor voltage no test Insulation Resistant for I O ports and the resistance of CT input Ambiance Temperature Temperature 20 75 c Humidity 35 85 RH Page 2 STYILONG WA Ranges Descriptions Initial limit 9999 C a value Alarm Lower 199 Set alarm lower limit and deviation of this limit under preset Limit 9999 C temperature value 5000 C Revision compensating thermal couple resistor Scaling setting 0 0 999 9 C Set interval control P 20 C in general or 50 C for Heating powerful heater Set P 0 for point control Integral Time Mostly 60 240S Increase I if temperature fluctuates 0 3600s o Repetitive regularly decrease I for persistent deviations Mostly 1 3 1 5 Increasing D lessens system s over heat but weaken the anti interference capabilit Set temperature control cycles 0 is unallowed Control Cycle Relay output 20 seconds Heating Logic level output drive SSR 2s 0 5V 4 20mA phase shifting voltage regulating output 1s Auto Calibration 0 Off 1 On See Control Panel User Input Lock 0 free to input 1 input 2 locked 4 Advanced Parameter Settings This intelligent series has advanced sett
6. iation can be corrected The amplifier of the cold side can return to zero by itself the precision is 2 FS Main outputs R Relay controlling AC contactor S Impulse zero triggering SSR Current output 4 20 mA impulse triggering Voltage regulator U Voltage output 0 5 VDC impulse triggering Voltage regulator Two kinds of independent output for alarming and twelve ways of alarming for upper lower limit are free to combine Page CHE HA 4 STYILONG FMM 2 ITC Technical Specifications 1 ITC Panel Layout TEMPERATURE CONTROLLER PV window in red shows the actual temperature and various functions symbols 2 SV window in green displays user s preset desired temperature factory initial settings and auto calibrated parameters as well as user s preset parameters 3 ON green light on indicates the output ports are open OFF green light go out am amz indicates the output port is closed OO OOOO O 4 AT light yellow flashes during ITC s auto calibration process ALM1 ALM2 Signal lights of two alarm channels red operating independently MD Mode selection key for presetting reviewing or confirming settings and AT D parameters DA Activating auto calibration move the cursor left when setting calibration parameters 8 Q Decrease or increase the values to the desired parameters 2 ITC Panel Display 1 Normal display After connecting to power the PV wi
7. ings Third level special parameters menu for engineers or senior experienced users Ordinary users had better not regulate the original parameters in order to avoid confusing procedures Method of operation to enter third level menu is as follow Press and hold both the MD and age keys at the same time until PASS is shown in the SV window and 0000 is shown in the PV window Then release ag KY after release MD key Input 01000 in the SV window to enter the menu code as follow thus you can reset or modify relevant parameters Press MD key to confirm after set or modify parameters in order then return to PASS and exit the menu Please refer to the table below password and operate in order Codes Symbol Definition Descriptions Values Ranges 1 behind model Precision 0 1 C 0 999 9 C E E1 K K1 N N1 J J1 5 Transmitter Eg K 1 C 1 1300 C K 0 1 C 0 999 9 C T T1 S R B Wer Cu50 Models Make changes over lines Pt100 0 5V 1 5V 0 10 Factory setting Model K1 mA 0 20mA 4 2mA 0 A Basic function 1 D Basic function 6 Kinds of 4 External interval alarm External alarm Upper Limit 10 A With alarm removal function 0 1 4 10 11 14 14 AL1P Alarms Settings Standby alarm Factory Initial setting A Absolute value 11 D With alarm removal function 1 D Offset value Standby alarm 14 External alarm With alarm removal function Standby alarm Page 3 CHE HA 4 STYILONG FEM 2 A Basic function
8. ndow will show transmitter types such as K and then current temperature SV window shows PID and then preset desired temperature 2 Normally the PV window may flash the following values HHHH input values are too high or incorrect settings on transmitter or input disconnect etc LLLL input values are too low or incorrect settings on transmitter connection error or input short circuit etc Erro Exchange parameter out of ranges incorrect settings on transmitter connection errors short circuit in input source or disconnect etc Values displayed in the PV window are correct despite the HHHH and LLLL errors but the PV values are incorrect under the error message Erro 3 ITC Technical Specifications 1 Technical Specifications specs tectnicat Parameter l Standard inputs all configurations Input Signals E E1 K K1 N N1 J J1 T T1 S R B Wer Cu50 Pt100 0 5V 1 5V 0 10mA 0 20mA 4 2mA Intelligent setting factory Initial setting P I D Temperature Control 1 Time proportional control modify I 0 D 0 2 Reach stop control modify P 0 Switch Control R Relay Contact S SSR zero triggering Output Control Modeling Control I 0 10mA 4 20mA continuous U 0 5V DC 1 5VDC continuous Relay Contact Load 250VAC 3A Resistance 250VAC 1A Conductive Cosp 0 4 Impulse Voltage Load 12VDC Max 40mA To drive SSR to protect short circuit Model C t EE Standard 0 5VDC 4 20mA Lo
9. plications YL 8 Series is an excellent controller for machineries in food processing glass making plastic forming publishing packaging and metal processing YL 8 Series is also the preferred temperature controller for processes such as temperature sensitive drying metal heat treatment and chemical and mechanic treatments This series of products has got the European CE certificate Product Features If the value displayed on the temperature controller is below 1000 c according to the types of sense transferring line 0 1 c or 1 c can be chosen The software has optimized and the precision is below 1 c The circuit of wide width switching power AC80 260V is widely suitable to many kinds of voltage good at resisting the interference of harmonic and in good stability In one word it can meet all the requirements from different working environments The producing technology of electronic chips SMC is adopted by the electronic components which generate less heat in good stability while working and has a long service life Without entering the menu the self tuning function will be activated by keeping pressing the AT button for a while Self tuning AT is fast stable and excellent Multiple kinds of standard signal thermocouple TC thermal resistance RTD analog quantity 4 20mA 0 5VDC and so on are free to input so as the measuring range The cold side of sense transferring line can test the temperature alone and the dev