Home
Operating Instructions
Contents
1. quick mounting and setup of a replacement component Please read this manual before you start setup 1 2 Target group This operating instructions manual is directed to trained personnel The contents of this manual should be made available to these personnel and put into practice by them 1 3 Symbolism used Information tip note This symbol indicates helpful additional information Caution warning danger This symbol informs you of a dangerous situation that could occur Ignoring this cautionary note can impair the person and or the instrument Ex applications This symbol indicates special instructions for Ex applications List The dot set in front indicates a list with no implied sequence Action This arrow indicates a single action Sequence Numbers set in front indicate successive steps in a procedure Electronics module VEGAFLEX series 60 3 For your safety VEBA 2 For your safety 2 1 Authorised personnel All operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the operator For safety and warranty reasons any internal work on the instruments must be carried out only by personnel authorised by the manufacturer 2 2 Appropriate use Oscillator emitting electronics housing or process compo nents are replacement components for existing sensors 2 3 Safety information for Ex areas Please not
2. CX CM CK GX acc to VEGA product list Electronics module FX E 60F suitable for VEGAFLEX 61 62 63 65 66 Foundation Fieldbus FF e FX E 60FX X without approvals e FX E 60KFC C approvals CX CK GX acc to VEGA product list 4 3 Mounting preparations VEGAFLEX 67 Electronics module FX E 67H suitable for VEGAFLEX 67 4 20 MA HART e FX E 67HX X without approvals e FX E 67HC C approvals XM CX CM CK Cl DX DM DI acc to VEGA product list Electronics module FX E 67P suitable for VEGAFLEX 67 Profibus PA e FX E 67PX X without approvals e FX E 67PC C approvals XM CX CM acc to VEGA product list Electronics module FX E 67F suitable for VEGAFLEX 67 Foundation Fieldbus FF e FX E 67FX X without approvals e FX E 67CFC C approval CX acc to VEGA product list Electronics module VEGAFLEX series 60 7 Mounting Mounting procedure VEBA 4 4 Mounting procedure The electronics module is located in the electronics compart ment The below illustrations show the respective position of the electronics compartment in a single or double chamber housing Fig 1 Single chamber housing 1 Position of the electronics module Fig 2 Double chamber housing 1 Position of the electronics module Proceed as follows 1 2 Switch off power supply Unscrew housing cover of the electronics compartment Disc
3. Operating Instructions Electronics module VEGAFLEX series 60 Vena Bin w e wr Contents VEBA Contents 1 About this document 1A FONCHOW 4 0 2 oa Re ERROR AS ee eee ae 4 1 2 Target group sus es ss EE DE Rd He RS EE 4 13 Symbolism used 0 0000 eee 4 2 For your safety 2 1 Authorised personnel 005 5 2 2 Appropriate use SESSE SE Se 5 2 3 Safety information for Ex areas 5 2 4 Environmental instructions 5 3 Product description 3 1 Configuration 0 0 0 0 eee 6 3 2 Principle of operation 2 6 3 3 Storage and transport 5 6 4 Mounting 4 1 General instructions 05 7 4 2 Mounting preparations VEGAFLEX 61 62 65 OO 24242244 Kenn ee AD OES LAERE RE 7 4 3 Mounting preparations VEGAFLEX 67 8 4 4 Mounting procedure 22222222220 9 5 Setup Sb Seis se ou een een ende 11 6 Maintenance 6 1 Instrument repair 000088 13 7 Dismounting 7 1 Dismounting procedure 14 7 2 Disposal cies sa nina 14 8 Supplement 8 1 Technical data 222222 15 Electronics module VEGAFLEX series 60 LO90SO NA LOGOE 30207 EN 050607 V Dm Vv About this document 1 About this document 1 1 Function This operating instructions manual has all the information you need for
4. e the Ex specific safety information for installation and operation in Ex areas These safety instructions are part of the operating instructions manual and come with the Ex approved instruments 2 4 Environmental instructions Protection of the environment is one of our most important duties That is why we have introduced an environment management system with the goal of continuously improving company environmental protection The environment ma nagement system is certified acc to DIN EN ISO 14001 Please help us fulfil this obligation by observing the environ mental instructions in this manual e Chapter Storage and transport e Chapter Disposal Electronics module VEGAFLEX series 60 LO90SO NA LOGOE 30207 EN 050607 VEBA Scope of delivery Area of application Packaging Storage and transport tempe rature Product description 3 Product description 3 1 Configuration The scope of delivery encompasses e Electronics module VEGAFLEX series 60 e Documentation this operating instructions manual 3 2 Principle of operation The electronics module VEGAFLEX series 60 is suitable for exchange with sensors acc to the guided microwave principle VEGAFLEX series 60 3 3 Storage and transport Your instrument was protected by packaging during transport Its capacity to handle normal loads during transport is assured by atest acc to DIN EN 24180 The packaging of standard instru
5. ments consists of environ ment friendly recyclable cardboard For special versions PE foam or PE foil is also used Dispose of the packaging material via specialised recycling companies e Storage and transport temperature see Supplement Technical data Ambient conditions e Relative humidity 20 85 Electronics module VEGAFLEX series 60 5 Mounting Sensor serial number Assignment 4 20 mA HART 2 ie VEBA 4 Mounting 4 1 General instructions If the electronics module is defective it can be replaced by the user In Ex applications only one instrument and one oscillator with appropriate Ex approval must be used If there is no electronics module available on site it can be ordered from the responsible VEGA agency The order data and company data of the sensor must be loaded in the new oscillator These are the options e atthe factory by VEGA personnel e oron site by the user Information When loading on site first of all the order data must be downloaded from the Internet see Setup In both cases the sensor serial number is necessary The serial numbers are stated on the type label of the instrument inside the housing or on the delivery note Caution The order data and company data contain important preset tings for the sensor A reliable operation and a correction of the measurement is not possible without these data Electronics modules are ada
6. onnect the connection cables acc to the operating instructions manual of the respective sensor Loosen the two screws with a Phillips screwdriver size 1 Electronics module VEGAFLEX series 60 LO90SO NA LOGOE 30207 EN 050607 VEBA Mounting Fig 3 Loosen the screws 1 2 5 9 Electronics module Screws 2 pcs Pull the previous electronics out by holding the opening levers Insert the new oscillator carefully Screw in and tighten the two screws with a Phillips screwdriver Connect the connection cables acc to the operating instructions manual of the respective sensor Screw the housing cover back on The electronics exchange is finished As a rule the exchange of the electronics must be Ex documented internally when used in Ex applications Electronics module VEGAFLEX series 60 9 Setup With sensor serial number Without sensor serial number Load sensor data 10 5 Setup 5 1 Setup If you have ordered the electronics module by stating the sensor serial number it is ready for operation after installation and connection to power supply If you have ordered the electronics module without stating the sensor serial number or you are using a suitable electronics module from stock you first have to load the sensor data after installation Move via www vega com to the item serial number search The order data of the
7. pted to the respective sensor They differ e g in the signal output the power supply or approval First of all check by means of the overview in section Mounting preparations if you are using the suitable electronics module Compare the new electronics module with the existing one The specifications on the type label must correspond This applies mainly to instruments with approvals 4 2 Mounting preparations VEGAFLEX 61 62 65 66 Electronics module FX E 60H suitable for VEGAFLEX 61 62 65 66 4 20MA HART Electronics module VEGAFLEX series 60 LO90SO NA LOGOE 30207 EN 050607 VEBA 4 20 mA HART four wire Profibus PA Foundation Fieldbus 4 20 mA HART Profibus PA Foundation Fieldbus Mounting e FX E 60HX X without approvals e FX E 60HA A approvals CA DA acc to VEGA product list e FX E 60HC C approvals XM CX CM CK Cl DX DM DI GX UX UF acc to VEGA product list Electronics module FX E 60V suitable for VEGAPULS 61 62 63 65 66 4 20 mA HART four wire e FX E 60VX X without approvals e FX E 60VA A approval DA 4 20 mA HART Vierleiter e FX E 60VC C approvals DX EX GX acc to VEGA product list Electronics module FX E 60P suitable for VEGAFLEX 61 62 63 65 66 Profibus PA e FX E 60PX X without approvals e FX E 60PA A approvals CA DA acc to VEGA product list e FX E 60PC C approvals XM
8. sensor will be displayed after entering the serial number Serial number 13796996 __Search Art cle na FASZ RA AGDLHEMAS Deliwery date 17 02 2004 Device VEGAFLEX 62 F llstandsensor nach dem Messprinzip der gef hrten Mikrowelle TOR Zulassung ohne Ausf hrung Werkstoff Basisausf hrung 1 Ad435 316L Proressanschluss Werkstoff Gewinde GIYA PNAD Ad35 316L Cuchtung Prozesstemperatur Vetony 30 150 C Elektronik 4 20m4 HARTE Gehause Schuteart Kumstetoff IPAE IPA7 Kabeleinfihrung Steckersnschluss M20x1 5 ohne Anzeige Bedienmodul PLICSCOM eingebaut Sprache des Men s DE Messstellenkennzeichnungsschld aus Edelstahllaser beschriftet Betriebsanleitung in DE Anzahl Betriebsanleitungen 1 000 Markierung PDI0AO01 CO2YLO1 LT1 Document Language File type File size Operating mstructon DE PDF 1018 KB sensor data for service DTM KHIL h 71 KB Right click on the image Choose Save target a5 to download the file to your hard drive Fig 4 Example for the order data of a sensor Below the order data you will find as an XML file Sensor data for Service DTM Load these data with Save target as to your PC and finally export them via PACTware and the Service DTM to the sensor Electronics module VEGAFLEX series 60 LO90SO NA LOGOE 30207 EN 050607 Ve Setup Adjustment As a rule settings already carried out on site with the previo
9. ules to be easily separable Mark the instrument as scrap and dispose of it according to government regulations electronic scrap ordi nance Materials see Technical data If you cannot dispose of the instrument properly please contact us about disposal methods or return Electronics module VEGAFLEX series 60 13 en MEER 8 Supplement 8 1 Technical data Technical data are stated in the operating instructions manual of the appropriate sensor 4 Electronics module VEGAFLEX series 60 LO90SO NA LOGOE 30207 EN 050607 VEBA Electronics module VEGAFLEX series 60 15 VEBA VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Phone 49 7836 50 0 Fax 49 7836 50 201 E mail info de vega com www vega com O CE amp All statements concerning scope of delivery application practical use and operating conditions of the sensors and processing systems correspond to the information avail able at the time of printing Technical data subject to alterations 30207 EN 050607
10. us electronics module such as min max adjustment gating out of false echoes etc however must be repeated Tip Simply use the copy function of the adjustment module PLICSCOM or the adjustment software PACTware Electronics module VEGAFLEX series 60 11 Maintenance 12 VEBA 6 Maintenance 6 1 Instrument repair If it is necessary to repair the replacement component please proceed as follows You can download a return form 23 KB from our homepage www vega com under Services Downloads Forms and Certificates Repair form By doing this you help us carry out the repair quickly and without having to call back for needed information e Print and fill out one form per instrument e Clean the instrument and pack it damage proof e Attach the completed form and possibly also a safety data sheet to the instrument e Send the instrument to the respective address of your agency In Germany to the VEGA headquarters in Schiltach Electronics module VEGAFLEX series 60 LO90SO NA LOGOE 30207 EN 050607 V Dismounting 7 Dismounting 7 1 Dismounting procedure Take note of chapters Mounting and Connecting to power Supply and carry out the listed steps in reverse order 7 2 Disposal The replacement component consists of materials which can be recycled by specialised recycling companies We have purposely designed the electronic mod
Download Pdf Manuals
Related Search
Related Contents
Model JEMUS Jägermeister Tap Machine® Owner Guide 超強力シール剥がし液(はがしキング)取扱説明書 Samsung 2043BW Manual de utilizare instrucciones para el uso - Ersatzteil 1DINセンターユニット Acer X243Hbmid Intel 8I845PE-RZ-C Computer Hardware User Manual Operating instructions Geberit AquaClean 5000plus Olympia PK 80 Ewent EW2675 Copyright © All rights reserved.
Failed to retrieve file