1. MAN 1000010164 EN Version L Status RL released freigegeben printed 18 05 2015 EN EN_00893619 Operating Instructions 1411 11 burkert Operating Instructions Type 6014 Design 3 way solenoid valve direct acting normally closed Circuit function C normally open Circuit function D or universal function Circuit function T Seal Materials and Fluids handled See Table 1 Fluid and Ambient Temperature For Hazardous Locations Div 1 T4 rated Max Ambient Temperature 104 F 40 C Max Fluid Temperature 194 F 90 C The FM Approved valve for Hazardous Locations is suitable for the fluids air inert gas water and gasoline For Hazardous Locations Div 1 T6 rated Max Ambient Temperature 104 F 40 C Max Fluid Temperature 140 F 60 C For Intrinsically Safe Apparatus for use in Class I Il and III Division 1 Hazardous Locations T6 rated Max Ambient Temperature 140 F 60 C Max Fluid Temperature 140 F 60 C For Hazardous Locations Div 2 and Ordinary Locations See Table 1 Pressure Range Maximum inlet pressure see label on valve Installation Before installing valve ensure that piping etc is free of foreign matter metal shavings pipe sealing materials welding scale etc Installation as required but preferable with coil uppermost Installation in this position tends to prevent foreign matter remaining in core tube increased life Do not put any loads on c
2. and 2 Operating Temperature T 4 UL listed for General Purpose CSA approved for General Purpose See label on the valve Material type Seat O ring Temperature Buna N NBR Fluid type Ethylene Propylene EPDM Fluid Air Ambient Fluid Ambient Light oil Fluid Ambient Fluid Ambient 14 to 194 F 10 to 90 C 14 to 130 F 10 to 55 C 32 to 194 F 0 to 90 C 32 to 130 F 0 to 55 C 14 to 194 F 10 to 90 C 14 to 130 F 10 to 55 C 14 to 194 F 10 to 90 C 14 to 130 F 10 to 55 C 14 to 266 F 10 to 130 C 14 to 130 F 10 to 55 C 32 to 212 F 0 to 100 C 32 to 130 F O to 55 C 14 to 266 F 10 to 130 C 14 to 130 F 10 to 55 C 14 to 266 F 10 to 130 C 14 to 130 F 10 to 55 C 32 to 212 F 0 to 100 C 32 to 130 F 0 to 55 C 14 to 266 F 10 to 130 C 14 to 130 F 10 to 55 C 14 to 266 F 10 to 130 C 14 to 130 F 10 to 55 C MAN 1000010164 EN Version L Status RL released freigegeben printed 18 05 2015 burkert Operating Instructions Wiring Diagram Electrical Connection Type 2509 Power Ground green dot Power Orientation is not important Electrical Connection Ensure supply voltage frequency corresponds with that on label Voltage tolerance is 10 Available Electrical Connections see Marking Wiring
3. diagram see above For this product to be considered UL listed and CSA approved for General Purpose and FM approved for Hazardous Locations Division 2 it must be in conjunction with the type 2509 cable plug connector Electrically Operated Valves Parts YSYI2 The connector and gasket must be assembled to the valve with the screw provided after the connection of the wire leads This valve and connector assembly is delivered together and is to be used as one unit For valves to be used in Intrinsically Safe Applications the positive pole is identified by a on the pin or wire No 1 has to be con nected to the See Control Drawing for the Rules of Interconnection Warning All valves to be used in Intrinsically Safe Applications must be clearly marked as Intrinsically Safe Apparatus Trouble Shooting Check port connections minimum operating pressure differential if required and supply voltage Ensure pilot hole in piston is clear and pilot bore in the valve outlet is not abstracted If core does not pull in check for short circuit coil burn out or foreign matter im peding core movement A jammed or missing core causes the coil to overheat in the case of AC supply Warning These products are designed to operate in a wide variety of ap plications it is the user s responsibility to select a model that is appropriate for the application This product is designed to be installed only by suitably qualified and trai
4. ned personnel Specifications should not be exceeded under any circumstances The torque for the terminal screw on type 2509 is 0 5 Nm 4 4 Ibf in Changes made to this product will render any applicable warranty null and avoid Specifications subject to change without notice Any questions Please call Biirkert Contromatic Technical Service at 949 223 31 00 burkert Germany Contact address Birkert Fluid Control Systems Sales Center Chr Burkert Str 13 17 D 74653 Ingelfingen Tel 49 0 7940 1091 111 Fax 49 0 7940 1091 448 E mail info de buerkert com International Contact addresses can be found on the Internet at www burkert com gt Burkert gt Company Locations
5. oil unit PTFE tape is recommended for sealing ports Mounting is accomplished by means of four M4 x 8 mm tapped holes located on the valve underside Letters on valve body indicate pressure port exhaust and outlet of the valve All listed valves type 6014 satisfied coil insulation H Epoxy material designated EP TABLE 1 Marking example Body Material BR Brass Ss Stainless Steel Seal Material EPDM EPDM NBR NBR FKM FKM Circuit function C Normally Closed D Normally Open T Universal Function 6014 C 5 64 NBR BR NPT1 4 PMAX 140PSI 24V 60Hz 8W 450000 gt Zz oO W Oo zZ MADE Item No Voltage Frequency Power Consumption Maximum Pressure Approvals The valve is either approved as General Purpose valve for Hazardous Locations Class I Division 1 Group A B C D Class II Division 1 Group E F G Class Ill Division 1 and 2 Operating Temperature T 4 or General Purpose valve for Hazardous Locations Class I Division 1 Group A B C D Class II Division 1 Group E F G Class Ill Division 1 and 2 Operating Temperature T 6 or Intrinsically Safe Apparatus for Hazardous Locations Class I Division 1 Group A B C D Class II Division 1 Group E F G Class Ill Division 1 Operating Temperature T 6 or FM approved a Nonincendive for Hazardous Locations Class I Division 2 Group A B C D Class II Division 2 Group F G Class Ill Division 1