1. mera the luminaire is switched on Each repeated long key button press causes a toggle between increased brightness and decreased brightness Specifying set value for brightness control Specifying the set value activates the brightness control a stented yy i Set the desired brightness coe Oe cml 2x Double click lt 30s 2 8 Confirmation luminaire flashes VI 2010 TouchDIM LS LI_ba1006en_we1 02 indd OSRAM GmbH Kunden Service Center Customer Service Center CSC e r OFO Deactivating brightness control sa ea I O Switch off if necessary r Double click Tel 49 0 1803 677 200 o gt gt V a a PATEA EN kostenpflichtig charges apply onfirmation maximum brightness Fax 49 0 1803 677 202 www osram com www osram de 4008321023025 Page 1 of 2 Operation cont Troubleshooting If you cannot remedy the fault please contact the Customer Service department of the luminaire manufacturer Luminaire does not function No mains voltage gt Use a voltage tester to check for mains voltage Illuminant is faulty gt Replace the illuminant The luminaire was switched off via the pushbutton gt Switch on the luminaire The sensor is exposed to excessive amounts of ambient light gt Hold the sensor closed and observe the behaviour of the luminaire Brightness is not adjusted to the selected set value The pushbutton was not pressed within 30 seco
2. OSRAM Description Purpose and application The TOUCH DIM LS LI sensor regulates the brightness at the workplace and in office areas to increase the working comfort TOUCH DIM LS LI and to save energy The sensor can be installed in luminaires e g floor standing luminaires or in false ceilings Function The sensor measures the brightness in the area to be regulated and keeps this to an adjustable set value by introducing artificial light according to the amount of daylight available As the amount of daylight increases artificial lighting is reduced Design The sensor is made up of the following components e Light sensor A e Housing B e Connections C for signal line neutral conductor and phase Light sensor Operating instructions Operation Symbols i Pushbutton on Q SA Luminaire on the luminaire Oo Switch on Luminaire off f y Luminaire I gt O Switch on a flashes Short press Brightness with gt lt 0 5 s automat control ed Long press Confirmation of eee 0 5 4s v4 the setting 0 gt Double click Manual dimming Switching luminaire on and off o O Via short press Note The luminaire is first switched on with minimum bright gt gt ness If a setpoint is predefined for brightness control the brightness is controlled automatically Changing the brightness manually Via long press Note The brightness control is deactivated until the next time ener
3. nds after the setpoint was adjusted gt Double click within 30 seconds after dimming manually Brightness control was not started until 5 seconds after the setpoint was adjusted gt Wait for the delay period to elapse Brightness control was deactivated by a manual operation gt Switch the luminaire off and on again No setpoint was saved gt Save a new setpoint Luminaire does not react as expected to the press of a button The pushbutton was pressed too long or too short gt See Changing the brightness manually Appendix The EMC requirements to EN 61547 are fulfilled Conformity with the relevant EU directives is confirmed by the CE symbol Page 2 of 2

Download Pdf Manuals

image

Related Search

Related Contents

Asrock H61M-DG3/USB3  Arrow BW54 Instructions / Assembly  5.障害者・高齢者のヒュー マンインターフェイス  honeywell destiny user manual  TDM-E400 TDM-C400 Quick Installation Guide  

Copyright © All rights reserved.
Failed to retrieve file