1. SJE Rhombus Installation and Operating Instructions SJE VERTICALMASTER PUMP SWITCH uss Patent No 5 155 311 amp Canadian Patent Pending SJE VERTICALMASTER Il PUMP SWITCH ss Patent No 6 140 925 amp Foreign Patents Pending SJE Rhombus pump switches provide automatic control of pumps in sump effluent and non potable water applications SPECIFICATIONS This equipment is suitable for Category II installations rated to 52 C and protected by double insulation Approved for use in non potable water SJE VERTICALMASTER PUMP SWITCH CABLE Flexible 16 gauge 2 conductor UL CSA SJOW water resistant CPE MOUNTING BRACKET amp HOSE CLAMP Stainless steel LIFT ROD Acetal LIFT ROD STOP PIN Nylon FLOAT STOP GROMMET Neoprene SWITCH AND FLOAT HOUSING high impact corrosion resistant PVC Switch and Float Overall 30 5 cm high x 12 7 cm x 7 6 cm wide Switch Housing 5 cm high x 7 1 cm wide has IPX7 protection Float Housing 6 4 cm high x 6 9 cm wide ELECTRICAL 120 VAC Rated Voltage Maximum Pump Running Current 13 amps Maximum Pump Starting Current 60 amps Frequency 50 60 Hz 230 VAC Rated Voltage Maximum Pump Running Current 13 amps Maximum Pump Starting Current 60 amps Frequency 50 60 Hz Switch must be used with pumps that provide integral thermal overload protection Switch is not recommended for controlling electric loads less than 2A 12 VAC or non arcing electric loads o CE S
2. SJE RHOMBUS SHALL NOT IN ANY MANNER BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AS A RESULT OF A BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY INEV TL ty ELECTRICALSHOCKHAZARD INV cy EXPLOSION ORFIRE HAZARD Disconnect power before installing or servicing this Do not use this product with flammable liquids product A qualified service person must install and eh 5 a Do not install in hazardous locations as defined by service this product according to applicable electrical tia National Electrical Code ANSI NFPA 70 and plumbing codes Failure to follow these precautions could result in serious injury or death Replace product immediately if switch cable becomes damaged or severed Keep these instructions with warranty after installation This product must be installed in accordance with National Electric Code ANSI NFPA 70 so as to prevent moisture from entering or accumulating within boxes conduit bodies fittings float housing or cable For detailed specifications on this product or for the complete line of SJE Rhombus panel alarm and switch products visit our web site at www sjerhombus com Figure B insert hose clamp through Warning Do not install switch in direct line of incoming liquid PRUNING Bracket sats 1 Determine desired activation level and pumping range as shown in Figure A Pumping range can be adjusted by moving the float stop up or down the rod 2 Insert hose clamp t
3. Box 1708 Mf Detroit Lakes Minnesota 56502 USA 1 888 DIAL SJE 1 888 342 5753 Mf Phone 218 847 1317 Mf Fax 218 847 4617 W E mail sje sjerhombus com Instl Instr PN 1012083C SJE Rhombus 04 08
4. JE VERTICALMASTER II PUMP SWITCH CABLE Flexible 18 gauge 2 conductor UL CSA SJOW water resistant CPE MOUNTING BRACKET amp HOSE CLAMP Stainless steel LIFT ROD Acetal LIFT ROD STOP PIN Nylon FLOAT STOP GROMMET Neoprene SWITCH AND FLOAT HOUSING high impact corrosion resistant PVC Switch and Float Overall 30 5 cm high x 12 7 cm x 7 6 cm wide Switch Housing 5 cm high x 7 1 cm wide has IPX7 protection Float Housing 6 4 cm high x 6 9 cm wide ELECTRICAL 125 VAC Rated Voltage Maximum Pump Running Current 10 amps Maximum Pump Starting Current 60 amps Frequency 50 60 Hz 250 VAC Rated Voltage Maximum Pump Running Current 10 amps Maximum Pump Starting Current 60 amps Frequency 50 60 Hz Switch must be used with pumps that provide integral thermal overload protection Switch is not recommended for controlling electric loads less than 100 miliamps 12 VAC or non arcing electric loads SJE RHOMBUS THREE YEAR LIMITED WARRANTY SJE RHOMBUS warrants to the original consumer that this product shall be free of manufacturing defects for three years after the date of consumer purchase During that time period and subject to the conditions set forth below SJE RHOMBUS will repair or replace for the original consumer any component which proves to be defective due to defective materials or workmanship of SJE RHOMBUS THIS EXPRESS WARRANTY DOES NOT APPLY TO THE MOTOR START KIT COMPONENT SJE RHOMBUS MA
5. KES NO WARRANTIES OF ANY TYPE WITH RESPECT TO THE MOTOR START KIT ELECTRICAL WIRING AND SERVICING OF THIS PRODUCT MUST BE PERFORMED BY ALICENSED ELECTRICIAN THIS WARRANTY DOES NOT APPLY A to damage due to lightning or conditions beyond the control of SJE RHOMBUSS B to defects or malfunctions resulting from failure to properly install operate or maintain the unit in accordance with printed instructions provided C to failures resulting from abuse misuse accident or negligence D to units which are not installed in accordance with applicable local codes ordinances or accepted trade practices and E to units repaired and or modified without prior authorization from SJE RHOMBUS Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state TO OBTAIN WARRANTY SERVICE The consumer shall assume all responsibility and expense for removal reinstallation and freight Any item to be repaired or replaced under this warranty must be returned to SJE RHOMBUSS or such place as designated by SJE RHOMBUS ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY
6. hrough slots in mounting bracket as shown in Figure B 3 Position hose clamp around discharge pipe with bracket gripping tabs against pipe Cable should remain outside of hose clamp ote aap 4 Tighten the hose clamp securely hose clamp 5 Secure pump cable and switch cable to discharge pipe as shown in Figure A with wire ties not supplied e 6 Wire switch as shown in Figure D Figure C 7 Check the installation Verify that the float is free to move and activate the switch Allow system to cycle to ensure proper mounting float bracket d operation guar hose Figure A clamp i lift rod stop pin lift Junction _float stop Figure D 125 250 VAC Normally Open Pump Down activation level L2 CONNECTIONS c L MADE IN DRY POWER pumping SOURCE SISS eae range SWITCH CABLE line of the circuit will always be HOT at the load This condition exists ifthe switch is on or off Install double pole disconnects on these circuits UF ALAS PREVENTATIVE MAINTENANCE e Periodically inspect the product Check that the cable has not become worn or that the housing has not been damaged so as to impair the protection of the product Replace the product immediately if any damage is found or suspected e Periodically check to see that the float and rod are free to move and operate the switch Use only SJE Rhombus replacement parts SJE Rhombus 22650 County Highway 6 Mf P O