1. YAZE 0001 3 Preparation Install the unit in a 19 system or bench case this is essential to ensure protection against contact with internal parts Have the safety checked by a qualified electrical technician Make the connection from the thermostat to the remote control FBT Section 1 2 1 3 YAZE 0001 30 05 06 Unpacking Preparation 9 LRUDR Remote Control FBT 4 Starting up 4 1 Connection to the supply Compare the information on the equipment label with the supply voltage Connect the equipment only to a socket with a protective earth PE connection No warranty when the equipment is connected to the wrong supply 4 2 Switching on Switch on thermostat and remote control FBT at the O mains switch The green LED on the FBT lights up Display on the FBT shows No Unit On the thermostat activate remote control in the Parameter menu PARA gt Thermostat Operating Instructions under Serial Interface Parameters Remote Control CC Dsm REM DEE A To activate the remote control switch the parameter REM on the thermostat to ONT The same information is now shown on the thermostat and on the remote control The keys on both units are activated 10 Starting up YAZE 0001 30 05 2006 Remote Control FBT LAUDA 4 3 Error If there has already been communication between remote control and thermostat check both units to ensure that there is st
2. the remote control FBT and also provides space for additional 19 panels of 1 6 width Equipment description YAZE 0001 30 05 2006 Remote Control FBT Remote control FBT Cat No LWZ 028 LWZ 428 223 5 4x 3 6 LAUDA 156 172 9 167 Bench case for FBT Cat No LWZ 027 235 240 5 50 E HA e m M K K LJ ll L YAZE 0001 30 05 06 Equipment description LRUDR 1 3 Equipment arrangement Remote Control FBT The remote control FBT can be used with all E 300 und RE 300 variants starting from Serial No Z04 001 and also all Integral process thermostats It requires software version 1 4 or above E 300 RE 300 and Integral Process thermostat Remote control FBT RS 2321485 Thermostat 65S 6fs ge RS 2321485 n aces 655 PCISPS etc When using the remote control FBT the function of RS 232 RS 485 is transferred to the socket 65 S on the FBT Equipment description YAZE 0001 30 05 2006 Remote Control FBT LAUDA 2 Unpacking After unpacking check first the equipment and accessories for possible transport damage If unexpectedly any damage can be noticed on the equipment it is essential to notify the forwarding agent or the postal authorities so that an inspection can take place Standard accessories Mains supply cable Cat No EKN 006 Operating Instructions Cat No
3. 36 We shall always be happy to deal with queries and to receive suggestions and criticism LAUDA DR R WOBSER GMBH amp CO KG P O Box 1251 97912 Lauda Koenigshofen Germany Phone 49 0 9343 503 0 Fax 49 0 9343 503 222 E mail info lauda de Internet http www lauda de YAZE 0001 30 05 06 Maintenance 13 LRUDR Remote Control FBT 6 Technical data F Module FBT Ambient temperature range Dimensions FBT WxHxD E Si 141 x 172 9 x 223 5 Module dimensions FBT Cl width 1 3 19 height 4U Weight Pig fot Mains supply 230 50 60 115 60 Protection Class 1 to DIN VDE 106 1 Power consumption W 12 Cat No 230V 50 60Hz LWZ 028 115V 60Hz LWZ 428 Units to EU Directives 89 336 EWG EMC and 73 23 EWG low voltage with CE mark Bench case for FBT Optional accessory Dimensions WxHxD ea 235 x 191 x 240 5 Weight tg Cat No LWZ 027 We reserve the right to make technical alterations 14 Technical data YAZE 0001 30 05 2006 BESTATIGUNG CONFIRMATION CONFIRMATION LAUDA An To A LAUDA Dr R Wobser LAUDA Service Center Fax 49 0 9343 503 222 Von From De Firma Company Entreprise StraBe Street Rue Ort City Ville Tel Fax Betreiber Responsible person Personne responsable Hiermit best tigen wir daB nachfolgend aufgef hrtes LAUDA Gerat Daten vom Typenschild We herewith confirm that the following LAUDA equipment see label Par la pr sente no
4. LRUDR Operating Instructions Remote Control FBT LAUDA DR R WOBSER GMBH amp CO KG P O Box 1251 97912 Lauda Koenigshofen GERMANY From Series Z 01 Phone 49 0 9343 503 0 05 06 T Fax 49 0 9343 503 222 From software version 0 1 E mail info lauda de YAZE 0001 Internet http www lauda de Remote Control FBT LAUDA Safety notes Before you operate this equipment please read carefully all the instructions and safety notes If you have any questions please phone us Follow the instructions on setting up operation etc This is the only way to exclude incorrect operation of the equipment and to ensure full warranty protection e Transport the equipment with care e Equipment and its internal parts can be damaged by dropping by shock e Equipment must only be operated by properly instructed personnel e Do not start up the equipment if itis damaged the supply cable is damaged e Have the equipment serviced or repaired only by properly qualified personnel e Switch off the equipment and pull out the mains plug for servicing and repair The Operating Instructions include additional safety notes which are identified by a triangle with an exclamation mark Carefully read the instructions and follow them accurately Disregarding the instructions can have serious consequences such as damage to the equipment damage to property or injury to personnel We reserve the right to make technical alterations YA
5. ZE 0001 30 05 2006 Safety Notes LRUDR Remote Control FBT Table of contents 1 EQUIPMENT DESCRIPTION uu ua issuu assaak ENEE dreet 6 Lt aseene ee Nee 6 12 Equipment combination and components uu 6 1 3 Equipment arrang mennt aiiissisisiassces is cadisstevccasvedsveaisse isensddcudacvesdsepavcssvdessveeisvadiverdieassaerstvecais 8 2 UNPACKING uuu eege dee ee eege EE erh 9 3 PREPARATION EE 9 r WW NC TER EE T TT 10 4 1 Connection tothe supply uu uuu anorni iiep ine iisip iaie au rrin arra arand siasa as 10 4 2 nat E EE 10 4 3 EMM OM TET E soceetecevsesavsaecs soveseusseavednavesssouandsveed E E T 11 4 4 Switch on and switch off u 11 45 elt BE 11 5 MAINTENANCE geed EE ee 12 5 1 e Ee D 12 5 2 Maintenance and repair u u u u u u uu uu EEN a a EEN usss awaspa ee akaqa aa aaa Eaa 12 Dade O Ko Ee EEN 13 6 RECHNEN 14 4 Table of contents YAZE 0001 30 05 2006 Remote Control FBT LAUDA Special Symbols Danger This symbol is used where there may be injury to personnel through incorrect handling Note Here special attention is drawn to some aspect May fe include reference to danger Reference Refers to additional information in other sections YAZE 0001 30 05 2006 Special Symbols 5 1 1 1 2 LRUDR Remote Control FBT Equipment description Basic principle The remote control FBT can be operated in conjunction with all Type E RE 300 and I
6. ill some communication If the connection is interrupted both units show an error message and there is a beep If one unit is switched off the other unit again shows an error message and there is a beep Message on the thermostat CC REM FAILA Message on the remote control No Unik lt The Error message can be acknowledged with the key When the connection has been restored acknowledgment is required only on the thermostat 4 4 Switch on and switch off Switching off It is useful to switch off the equipment combination in the following sequence in order to avoid unnecessary error messages which have to be acknowledged reset Thermostat OFF There is an error message No Unit on the remote control FBT Remote control FBT OFF Switching on The order is immaterial 4 5 Key inhibit KEY gt Only the keys on the thermostat can be inhibited Inhibiting and de inhibiting can be operated either from the thermostat or from the remote control See Thermostat Operating Instructions YAZE 0001 30 05 06 Starting up 11 LRUDR Remote Control FBT 5 Maintenance 5 1 Cleaning Before cleaning the equipment pull out the mains plug The equipment can be cleaned with water with the addition of a few drops of detergent washing up liquid using a moist cloth Water must not enter the equipment Carry out appropriate de contamination if dangerous material has been sp
7. illed on s gt or inside the unit Method of cleaning and de contamination are decided by the special knowledge of the user In case of doubt contact the manufacturer 5 2 Maintenance and repair Before any maintenance and repair work pull out the mains plug Repair on the equipment must only be carried out by properly qualified personnel If a fuse has blown gt mains supply indicator no longer alight fit only fuses as IS specified 2 x T 2 5 A size 5 x 20 gt fuses are located on the equipment UL 499 C F3 T2 5A F2 T2 5A 12 Maintenance YAZE 0001 30 05 2006 Remote Control FBT LAUDA Before you return the equipment it is advisable to contact our Technical Service department LAUDA Service Center a Phone 49 0 9343 503 236 Ifthe equipment has to be returned to the factory please ensure that it is packed Ee carefully and properly LAUDA accepts no responsibility for damage due to unsatisfactory packing 5 3 Ordering spares When ordering spares please quote type and serial number from the equipment label This avoids queries and supply of incorrect items Responsible for all service problems LAUDA Service Center Phone 49 0 9343 503 2
8. ntegral thermostats Except for the adjustment of the overtemperature switch off point the unit contains the same operating and indicating functions which can be performed on the thermostat panel Display and keys correspond to those of the basic thermostat The indication takes place in parallel with the basic thermostat Inputs can be made both on the basic thermostat and also on the remote control Communication is via the serial interface of the basic thermostat The interface RS 232 RS 485 for an external computer e g PC is transferred to the remote control FBT when this is installed Equipment combination and components The remote control FBT consists of a 19 panel of 1 3 width and 4 height units Cat No LWZ 028 It incorporates its own built in power supply A mains supply cable is included A cable with 9 pin SUB D plug and socket is required for communication Such a cable can be provided in different ways 1 LAUDA offers a cable 5 m long Cat No EKS 057 or a cable with length to customer specification 50 m max Cat No UK 258 2 Purchase of a commercially available RS 232 cable without twisted cores do not use a null modem cable 3 Manufacture by the user to the drawing below Use screened cable The screens should be connected to the connector case Pins not in use must not be connected s 1 Maximum length 50 m IS In addition a 19 case can be supplied Cat No LWZ 027 This takes
9. us confirmons que l appareil LAUDA voir plaque signal tique Typ Type Type mit folgendem Medium betrieben wurde was used with the below mentioned media a t utilis avec le liquide suivant Dar ber hinaus best tigen wir da das oben aufgef hrte Ger t sorgf ltig gereinigt wurde die Anschl sse verschlossen sind und sich weder giftige aggressive radioaktive noch andere gef hrliche Medien in dem Ger t befinden Additionally we confirm that the above mentioned equipment has been cleaned that all connectors are closed and that there are no poisonous aggressive radioactive or other dangerous media inside the equipment D autre part nous confirmons que l appareil mentionn ci dessus a t nettoy correctement que les tubulures sont ferm es et qu il n y a aucun produit toxique agressif radioactif ou autre produit nocif ou dangeureux dans la cuve Stempel Datum Betreiber Seal Cachet Date Date Responsible person Personne responsable Formblatt Form Formulaire Unbedenk doc LAUDA DR R WOBSER GmbH amp Co KG Erstellt published tabli LSC PfarrstraBe 41 43 Tel 49 0 9343 503 0 And Stand config level Version 0 1 D 97922 Lauda K6nigshofen Fax 49 0 9343 503 222 Datum date 30 10 1998 Internet http www lauda de E mail info lauda de UNBEDENK DOG