Home

INSTALLATION AND OPERATING INSTRUCTIONS for VMS

image

Contents

1. Installation with Single level Regulator Installation with double level Regulator Installation avec 1 R gulateur de niveau Installation avec 2 R gulateurs de niveau Pump OFF Pump OFF t DE ls Level Level Hits ia Fixingpipe df rentiel diff rentiel A Tuyau de fxage i TS Pump Pump ON ON L black L black noir m a IMPORTANT blue bleu Installation systems N blue bleu valid only for models blue bleu VMS C Mi Syst mes d installation nn Pump OFF valides seulement pour Level drop Niveau diff rentiel mod les VMS C Y pymp ON N Fig 2 The wire that is not be used must be correctly insulated Le conducteur qui n est pas utilis doit tre correctement isol Installation of counterweight Installation contrepoids an e I a e 3 a VALCO FLOAT SWITCHES AND LEVEL REGULATORS NI L ZA INSTALLATION AND OPERATING INSTRUCTIONS for PCMF Level Regulators Mercury free to RoHS Directive for wastewater PCMF Level Regulators Mercury free to RoHS Directive for wastewater Submerged float switch Water resistant to 100 m depth insensitive to humid ity and condensation with new concept electric con tacts consisting of e Change over 10
2. PUMPS MOTORS and CONTROLS MANUFACTURING FABRICATION DE POMPES MOTEURS ET DISPOSITIFS DE CONTROLE ET DE NIVEAU water is the future VALCO Established in Marostica Italy since 1976 worldwide INSTALLATION AND OPERATING INSTRUCTIONS for VMS C and PCMF Level Regulators E M INSTRUCTIONS POUR L INSTALLATION ET L UTILISATION VALCO des R gulateurs de Niveau VMS C et PCMF Etablie Marostica ltalie depuis le 1976 et avec pr sence mondiale Counterweight provided on request Contrepoids fourni sur C demande Made in Italy VMS C PCMF Fabriqu en Italie Microswitch Level Level Regulators Mercury free to RoHS R gulateurs de Niveau Directive for wastewater microswitch Regulators Float Switches R gulateurs de Niveau sans ampoule mercure pour eaux charg es VALCO Works Pump amp Motor Test Laboratory Pumps and Electric Motors Research Centre Usine Laboratoire Essais Centre de Recherche Pompes et Moteurs NI L ZA INSTALLATION AND OPERATING INSTRUCTIONS for VMS C Microswitch Level Regulators VMS C Microswitch Level Regulators The appliance combined with a pump connected by a flexible cable permits the regulation of the level of the liquid in which it is immersed The regulator in fact features a float with a totally waterproof casing inside which there is a microswitch connected to the cable The float position depends on the liquid level
3. 250 V self cleaning switch by each operation with a high distance between contacts APPLICATIONS Regulation of particularly turbulent industrial waters containing residues of suspended agglomerates or of sewer waters for emptying and filling any type of tank with turbulent industrial liquids with sewage water with waters liquids with solids in suspension TECHNICAL CHARACTERISTICS e Mercury free to RoHS Directive for wastewater The submerged float switch model PCMF consists of e single outer piece in blowmoulded Polyethylene e Internal weight fixing the rotation centre gravity cen tre close to the cable connection e Self cleaning contacts 10 A 250 V a c electric control switch with high distance between the contacts The float switch is filled with closed cells nonhygroscopic expanded polyurethane eliminating all air sealing the unit and completely surrounding the electric control Switch MAX WORKING TEMPERATURE 55 C AVAILABLE CABLES PVC NEOPRENE and special cables on request ER INSTRUCTIONS POUR L INSTALLATION ET L UTILISATION des R gulateurs de Niveau PCMF Sans ampoule mercure pour eaux charg es PCMF R gulateurs de Niveau sans ampoule mer cure pour eaux charg es pour eaux usees d egouts R gulateur de niveau type PMCF Submerg tanche l immersion 100 m de profondeur insensible l humidit et la condensation muni de contacts lectriques de nou vel
4. Lors des connexions susdites ne pas oublier de v rifier si le courant maximum du moteur correspond aux valeurs indiqu es sur le r gulateur de niveau Le c ble d alimentation fait partie int grante du dispositif Dans le cas o le c ble serait abim le dispositif doit tre obligatoirement remplac le c ble en effet ne peut pas se r parer Le conducteur de terre de couleur jaune vert doit tre connect un bornier de terre adapt et doit avoir une section non inf rieure 1 mm Le bornier utilis doit tre efficacement prot g contre les des serrements accidentels MAXIMUM OPERATIONAL TEMPERATURE TEMPERATURE D UTILISATION MAX ME IP68 tested by IMQ at a depth of 1m for a period of 7 days at water PROTECTION GRADE temp of 50 C DEGRE DE PROTECTION IP68 test par IMQ la profondeur de 1 m pendant 7 jours temp de leau 50 C The appliances pass an immersion test at depth of 10 m at a tem FACTORY RELIABILITY TEST perature of 50 C for a period of 7 days ESSAI DE FIABILITE Les dispositifs ont franchi sans probl me l essai de plong e 10 m de profondeur la temp rature de 50 C pendant 7 jours POLLUTION GRADE NORMAL DEGRE DE POLLUTION NORMALE FEATURES OF AUTOMATIC ACTION TYPE D ACTION CARACTERISTIQUE 1B micro disconnections in operation 1B micro connexion en fonctionnement The regulators are homologated in compliance with CEI EN 60730 standards and thereby comp
5. OFF Pump OFF valides seulement pour _ aii TOS mod les PCMF Level drop Niveau diff rentiel Pump ON i DS N Fig 5 The wire that is not be used must be correctly insulated Le conducteur qui n est pas utilis doit tre correctement isol VALCO FLOAT SWITCHES AND LEVEL REGULATORS Exclusive High Tech Pumps for Water and other Fluids Motors and Controls in Standard or Custom Designs manufacturing of Electric Pumps Borehole Submersible Drainage and Sewage Surface Centrifugal Close Coupled Controls and Fittings for Pumps and Pumping Instal lations Electric Motors Compact AC Power in Standard or Custom Designs Exclusive High Tech Pumps for Water and other Fluids Motors and Controls We also manufacture and supply Nous fabriquons aussi Pompes exclusives de haute technologie pour eau et autres fluides moteurs et dispositifs de contr le et de ni veau en executions standards et sp ciales VALCO la gamme la plus vaste et compl te de pompes pour usages domestiques collectifs pour l agriculture l in dustrie forages puisement ass chement eaux us es et charg es surpression Une source et un service fable pour les pompes et le me teurs lectriques une solution unique globale innovative et comp titive pour le Pompage et le Moteurs Sold by VALCO distributor Authorized VALCO dealer Vendu par le Distributeur VALCO suivant If repairs are required conta
6. and de termines the commutation of the microswitch which in turn controls the pump operation INSTALLATION To ensure the efficient function of the appliance it is necessary to fix the electric cable inside the tank or well as illustrated in figures no 1 and no 2 The length of the cable section between the fixture point of the same and the regulator body determines the total extension of the float and the consequent distances between the pump stopping and starting level It is also neces sary to check that the float is not obstructed during its run During installation joints to the level regulator cable must not be made under any circumstances An eventual cable joint section must never be immersed in water COUNTERWEIGHT INSTALLATION IF PRESENT For correct counterweight installation refer to the fol lowing procedure as illustrated in figure no 3 Insert the cable into the counterweight from the conical side turning it This will result in the detach ment of the plastic ring inserted in the mouth if necessary aid detachment by using a screwdriver Place the ring at the point of the cable where the counterweight is to be fixed 2 Fix the counterweight on the ring using moderate pressure and turning it The counterweight is only provided on request ER INSTRUCTIONS POUR L INSTALLATION ET L UTILISATION des R gulateurs de Niveau microswitch VMS C VMS C R gulateur de Niveau microswitch Le disp
7. facilit avec un tourne vis l anneau sera plac dans la partie du c ble devant accueillir le contrepoids 2 Forcer en douceur le contrepoids sur l anneau en le tour nant Le contrepoids n est fourni que sur demande VALCO FLOAT SWITCHES AND LEVEL REGULATORS ELECTRICAL CONNECTIONS The regulator may be used for filling or emptying ac cording to the connections made between the termi nals of the microswitch and the cable For correct product installation refer to wiring diagrams in figures no 1 2 NOTE When making the connections described above en sure that the maximim motor power does not exceed the values indicated on the level regulator The power supply cable is an integral part of the appli ance Should the cable be found to be damaged the appliance is to be replaced Repairs to the cable itself are not possible The earth wire of yellow green colour must be con nected to a suitable earth terminal and the section dimension must not be less than 1 mm The even tual terminal used must be effectively protected against accidental slackening ELECTRICAL FEATURES CARACTERISTIQUES ELECTRIQUES BRANCHEMENTS ELECTRIQUES Le r gulateur peut tre utilis tout aussi bien pour le rem plissage que pour le vidage en fonction des branchements effectu s entre les terminaux du microcontact et le c blage Pour une installation correcte il faut se reporter aux sch mas lectriques des figures 1 2 NOTES
8. ct an authorized VALCO dealer Pour Entretien veuillez contacter notre Distribu teur VALCO VALCO International trademark water is the future Pumps Motors and Controls Manufacturing VALCO srl Via dell Industria 27 29 l 36063 MAROSTICA Vicenza Veneto Venice Region EU Italy Ph 39 0424 77847 Fax 39 0424 475806 HEAD OFFICE WORKS PUMP amp MOTOR TEST LABORATORY PUMP amp MOTOR RESEARCH CENTRE PUMPS amp WATER HANDLING UNIVERSITY E Mail valco valco costenaro com Http www valco eu Manufacturer of Useful and Valuable Products for Progress Prosperity and Peace All rights reserved Reproduction even partial not permitted Features subject to change not contractually valid unless specifically authorized by VALCO Caract ristiques techniques passibles de changement_photos et descriptifs ne sont pas contractuels au moins que ils ne soient express ment confirm s et authoriz s par crit par Valco srl VALCO is a registered trademark of Valco srl Text by Valco srl Copyright 1976 2010 by VALCO srl ref 1 MAINT VMS C PCME EN FR 11 2010rev 0
9. eurs de niveau Pump Pump ON ON Level Level drop drop Niveau Niveau diff rentiel diff rentiel Pump Pump OFF OFF L brown IMPORTANT L brown marron black noir marron Installation systems valid only for models 7 N black noir HE black noir Syst mes d installation valides seulement pour nn om ON mod les PCMF Level drop Niveau diff rentiel nt Pump OFF N Fig 4 The wire that is not be used must be correctly insulated Le conducteur qui n est pas utilis doit tre correctement isol Installation and wiring diagram for filling pump Installation et sch ma de branchement pour pompe de remplissage Installation with Single level Regulator Installation with double level Regulator Installation avec 1 R gulateur de niveau Installation avec 2 R gulateurs de niveau Pump or Pump OFF t t Level es Level drop LT drop Niveau Counterweight Niveau Fixing pipe diff rentiel Contrepoids diff rentiel M Tuyau de fxage Pump ON L M brown IMPORTANT k aron blue bleu marron Installation systems TET valid only for models f J PCMF blue bleu l Syst mes d installation p
10. le conception constitu par Commutateur 10A 250 Vc a contacts autonettoyants chaque manoeuvre et une grande distance d ouverture UTILISATION R gulation d eaux industrielles particuli rement turbu lentes contenants des r sidus d agglomer s en suspension ou pour des eaux d gouts CARACTERISTIQUES TECHNIQUES Sans ampoule mercure pour eaux charg es Le r gulateur de niveau submerg type PCMF se compose de e Corps ext rieur en poly thyl ne souffl sous pression en une seule pi ce Poids int rieur pour d terminer le point de rotation bary centre proximit de l entr e du c ble Commutateur de commande lectrique 10 A 250 V c a contacts autonettoyants et une grande distance dou verture l int rieur du r gulateur seffectue une injection de polyur thanne expans cellules ferm es non hygros copiques qui limine toutes les particules d air ferme le tout et rend le commutateur de commande lectrique tanche Tmax 55 C CABLES DISPONIBLES PVC NEOPRENE et autres sur demande EH VALCO FLOAT SWITCHES AND LEVEL REGULATORS Installation and wiring diagram for emptying pump Installation et sch ma de branchement pour pompe de vidange Installation with Single level Regulator Installation with double level Regulator Installation avec 1 R gulateur de niveau Installation avec 2 R gulat
11. ly with the fundamental requisites of Directive 93 68 EEC Les r gulateurs sont homologu s selon les normes CEI EN 60730 et de ce fait sont conformes aux principales r gle mentations de la directive 93 68 CEE VALCO FLOAT SWITCHES AND LEVEL REGULATORS Installation and wiring diagram for emptying pump Installation et sch ma de branchement pour pompe de vidange Installation with Single level Regulator Installation with double level Regulator Installation avec 1 R gulateur de niveau Installation avec 2 R gulateurs de niveau Pump Pump ON ON Level eve la Z _ Counterweight dro cA S y meu I A 7 diff rentiel diff rentiel i Pump Pump OFF OFF black L black noir m a IMPORTANT brown marron Installation systems N brown marron valid only for models br own Marron VMS C E Syst mes d installation Pump ON valides seulement pour z a A S ET mod les VMS C lt rop Ivea u ditrerentie TV pump OFF N Fig 1 The wire that is not be used must be correctly insulated Le conducteur qui n est pas utilis doit tre correctement isol ES VALCO FLOAT SWITCHES AND LEVEL REGULATORS Installation and wiring diagram for filling pump Installation et sch ma de branchement pour pompe de remplissage
12. ositif accoupl une pompe par un c ble flexible permet de r gler le niveau du liquide dans lequel il est plac Chaque r gulateur se compose en effet d un carter flottant enti rement tanche l int rieur duquel se trouve un microcontact reli au c ble flexible La position prise par le flotteur en fonction du niveau du liquide d termine la commutation du microcontact en commandant l ac tionnement de la pompe INSTALLATION Pour un fonctionnement correct du dispositif il faut fixer le c ble lectrique l int rieur de la cuve ou du puits comme indiqu sur les figures 1 et 2 La longueur de la partie de c ble comprise entre le point de fixation et le corps du r gulateur d termine lexcursion totale du flotteur et par cons quent la distance entre le niveau d arr t et de d mar rage de la pompe il faut galement contr ler que rien ne puisse g ner le flotteur durant sa course Pendant l instal lation il faudra absolument viter deftectuer des joints du c ble du r gulateur de niveau En cas de joint ventuel du c ble celui ci ne devra pas toucher l eau INSTALLATION DU CONTREPOIDS SI PRESENT Pour que l installation du contrepoids soit correcte il faut suivre la proc dure illustr e sur la figure 3 1 Introduire le c ble dans le contrepoids du c t conique en le tournant Ceci provoquera le d tachement de l anneau en plastique plac l embouchure en cas de besoin le d tachement peut tre

Download Pdf Manuals

image

Related Search

Related Contents

Owners Manual - Powered by StratumSites  Operating Manual - SUNNY ISLAND 3.0M / 4.4M / 6.0H / 8.0H  Mac Viewer Manual  Bedienungs- und Wartungsanleitung  取扱説明書 取付・設置説明書  3/8 in. Right Angle Air Drill  ThinApp-Benutzerhandbuch  KUDA 238020 holder  Uniden GMR855-2CK Portable Radio User Manual  Yamaha 6JM User's Manual  