Home

Installation manual

image

Contents

1. Co7 LN 0 gt C08 cD010308 001 A Colour display not included in delivery B Computer not included in delivery C Transceiver Unit D Transducer E Power supply Important If you wish to use more than one transceiver you must use an Ethernet switch between the computer and the transceivers 351719 A 25 Simrad EK15 List of cables Observe the list of cables for the Simrad EK15 The Cx numbers refer to the cable plan References are made to the individual cable drawings specifying each cable with its connectors C1 C2 C3 C4 C5 26 AC mains to colour display This cable is provided with the display It is a standard commercial mains cable The display end is normally terminated with an IEC C13 inline socket The other end is terminated in an AC connector suitable for the local conditions If this is not the case you must replace the AC connector The typical cable length is between 1 5 and 2 meters If this is too short you must use an extension cable not recommended mount a new power outlet within range or make your own power cable AC mains IEC 60320 on page 29 AC mains to computer This cable is provided with the computer It is a standard commercial mains cable The computer end is normally terminated with an IEC C13 inline socket The other end is terminated in an AC connector suitable for the local conditions If this is not the ca
2. Note This is a critical task You must ensure that the correct transducer is selected If you connect the transceiver to a transducer that can not handle the power rating it may be damaged beyond repair On the EK15 always choose transducer ES10 Observe that the status for the relevant frequency channels changes to nstalled Click OK to save the current settings and close the dialog Start normal operation This procedure explains how to set up the EK15 for normal operation a Observe the Main menu It is normally located on the right hand side of the EK15 presentation Click the Operation icon This icon is located under the Main menu It is used to open the Operation menu A Click the Operation button and select Normal 351719 A Installation Installing a frequency channel This procedure explains how to install a frequency channel Important You must have a valid software license on your EK15 computer to set up a frequency channel Each EK15 transceiver with its transducer and single frequency is referred to as a frequency channel The upper part of the Transceiver Installation dialog displays a list of frequency channels which either are or have been installed on the EK15 For each channel on the list a Status label is provided The following status values are available in the Transceiver Installation dialog e Busy The frequency channel is already in use probably by another echo
3. quality Ethernet cable RJ45 Ethernet straight on page 30 Interface to peripheral devices These interfaces include relevant sensors as well as a printer 351719 A 27 Simrad EK15 Cable drawings The drawings provided specify in detail each cable used by the Simrad EK15 Topics e AC mains IEC 60320 on page 29 e RJ45 Ethernet straight on page 30 e Transceiver Unit connections on page 32 28 351719 A Cable layout and interconnections AC mains IEC 60320 This is a commercial 230 Vac power cable for mains power One end is fitted with an IEC plug the other with a standard European mains plug This is a standard cable type supplied in different lengths Live Neutral normally Blue normally Brown IEC C13 Ground no line socket A 7 always Yellow or Yellow Green There are substantial differences between American and British nomenclature related to power plugs and sockets Commercial power cable for AC mains Cable specifications e Conductors 2 x 1 5 mm GND e Screen None e Voltage 750 V e Maximum diameter Set by the plugs More information e http en wikipedia org wiki IEC_320 351719 A 29 Simrad EK15 RJ45 Ethernet straight This cable is used to provide standard Ethernet connections Note that various categories exists Normally CAT 5E and CAT 6 cables are used in local area networks with bandwidth exceeding 100 Mbit Ethernet cables are available commercially in diffe
4. 02 3ab e Not applicable This is a commercial cable More information e http en wikipedia org wiki TIA EIA 568 B e http en wikipedia org wiki Category 5 cable 351719 A 31 Simrad EK15 Transceiver Unit connections These are the transducer and power cables that connect to the transceiver Both cables are provided in the package with the EK15 12 Vdc Transducer Ground Transducer Transceiver Unit connections 32 351719 A Technical specifications Technical specifications This chapter provides the technical specifications and requirements related to the Simrad EK15 In Simrad we are continuously working to improve the quality and performance of our products Technical specifications may therefore be changed without prior notice Topics Performance specifications on page 34 Weights and outline dimensions on page 35 Power specifications on page 35 Minimum computer requirements on page 36 Minimum display requirements on page 37 351719 A 34 Simrad EK15 Performance specifications This section provides the performance specifications for the Simrad EK15 Operational frequency e 200 kHz Typical range e 200 meters Transmission e Simultaneous or sequential e Ping rate Up to 40 Hz e Pulse durations 80 to 1240 us Transceiver Unit e Data rate 1 6 Mbps e Maximum number in use 15 e Output power 45 W e IP rating IP66 Calibration e Built in
5. NS cccccccccccccccccccccccccccccsensees 33 Performance specifications 5 055 vszcsncesvecsnnasbeuscpsatdocesinaadstanseasieccresusdolscossadietdssbaniaedvasere 34 Weights and outline dimensions s5as5sincaseesdiucosan Naxsaaesiexosann narnia actaanelinceraelacweens 35 Power specification Senideei e i i net EE e 35 Minimum computer requirements 2sscsssscconassccsssesacsadssosessadeessdsoeseesavencdessasnacdeasens 36 Minimum display TSG UALEMIGINS SES nes uen ent 37 DRAWING FILE issssssc snsssssasdusvessses ssseseseensaess 38 Transducer outline dimensions issues 39 Transceiver outline dimensions ui iii 40 351719 A 3 Simrad EK15 4 351719 A About this manual About this manual Purpose The purpose of this manual is to provide the information and basic drawings required for installation of the Simrad EK15 For more detailed information about the practical use of the product refer to the Simrad EK15 Operator manual or the Simrad EK15 Reference manual Target audience The manual is intended for technical personnel qualified maintenance engineers and technicians It is assumed that the personnel is conversant with the general principles of maritime electronic equipment in particular sonar echo sounder and catch monitoring systems The personnel must also be familiar with computer hardware signal processing interface technology and traditional troubleshooting on electronic and mechanical products We assume that you ar
6. Simrad EK15 Multi purpose scientific echo sounder Echogram TVG School Beam Direction Upwards ctor Calibration R 06 05 2010 10 39 14 www simrad com TECHNOLOGY FOR SUSTAINABLE FISHERIES KONGSBERG Simrad EK15 Installation manual This manual provides you with the basic information required to install the Simrad EK15 For more detailed information about the practical use of the product refer to the Simrad EK15 Operator manual or the Simrad EK15 Reference manual All user documentation is included on the software media provided with the Simrad EK15 The manuals can also be downloaded from http www simrad com ek15 The Simrad EK15 transducer is not designed for hull mounting 351719 A 24 02 2010 Kongsberg Maritime AS Revision status Document no 351719 ISBN 13 978 82 8066 147 0 Revision A Rev A 24 02 2012 First version License information When you have obtained the necessary licenses to operate the EK15 we strongly advice that you write down the hardware ID and the license codes on this page License code License code License code Copyright 2012 Kongsberg Maritime AS The information contained in this document remains the sole property of Kongsberg Maritime AS No part of this document may be copied or reproduced in any form or by any means and the information contained within it is not to be communicated to a third party
7. apters are available and Simrad has not tested all of them Even adapters that meet the minimum specifications may fail with the EK15 software We welcome any feedback with comments or experiences with graphic adapters e Interfaces The computer must offer minimum one Ethernet interface Two are required if the computer shall also be connected to a local area network LAN One or more serial line interfaces are also required The number of serial lines depend on the interface requirements If you have connected a USB to serial adapter to the computer do not remove it while the EK15 is running Also do not move the adapter to a different USB socket on the computer e Operating system The EK15 software has been designed for 32 bit Windows 7 For all new EK15 installations we recommend that Windows 7 is used 36 351719 A Technical specifications Minimum display requirements Unless specifically ordered from Simrad the EK15 is not provided with a colour display This item must be purchased locally You can use one or two displays one your EK15 computer depending on personal and operational preferences It is important to make sure that the chosen display model meets the technical system requirements Make sure that the display design and construction allow for marine use easy access to cables and a safe installation The minimum requirements are e Resolution Minimum 1280 x 1024 pixels e Interfaces Must match the v
8. box providing all necessary transmitter and receiver electronics The receiver is designed for low noise and it can handle input signals spanning a very large instantaneous dynamic amplitude range All targets are correctly measured and displayed A high quality Ethernet cable connects the EK15 Transceiver Unit to the computer The distance between the computer and the transceiver can be extended up to maximum 70 meters If a longer cable is required cut it in half and insert an Ethernet switch half way to provide buffer amplification If more than one transceiver is used a high speed Ethernet switch is required to connect the transceivers to the Processor Unit The EK15 Transceiver Unit requires an external power supply offering 12 Vdc A suitable power supply is provided with the delivery EK15 Transducer The Simrad EK15 is provided with a suitable single beam transducer A 20 m cable is connected to the transducer and the cable is terminated in a plug that fits the socket on the transceiver The Simrad EK15 transducer is not designed for hull mounting Ethernet switch If you use more than one transceiver you will need an Ethernet switch Most commercial types can be used Note that the Ethernet switch is not a standard part of the EK15 delivery 351719 A 11 Simrad EK15 Scope of supply Please observe the standard and optional parts provided with the Simrad EK15 delivery Standard parts Part unit name and d
9. cial wireless systems 351719 A 9 Simrad EK15 System units The Simrad EK15 comprises the following units Topics e Colour display on page 10 e Computer on page 10 e Transceiver Unit on page 11 e EKIS Transducer on page 11 e Ethernet switch on page 11 Colour display Any commercial colour display can be used with the Simrad EK15 system The chosen display must be designed for maritime use and it must meet the minimum performance specifications If you use a large number of transceiver you will find it useful to use a large display with high resolution The EK15 software supports all display sizes The fidelity of your echogram presentation depends on the quality of your graphic adapter and display Note that the colour display is not a standard part of the EK15 delivery Related topics e Minimum display requirements on page 37 Computer The Simrad EK15 system is designed to be controlled by a commercial maritime computer This computer must be based on the Microsoft Windows 7 operating system It must be designed for rugged use and must be able to withstand the vibrations and movements of a vessel Note that the computer is not a standard part of the EK15 delivery Simrad may provide a suitable maritime computer Consult your dealer for more information Related topics e Minimum computer requirements on page 36 10 351719 A Simrad EK15 Transceiver Unit The EK15 Transceiver Unit comprises a small rugged
10. close the dialog Changing the IP addresses when more than one transceiver is used This procedure explains how to modify this IP address The transceivers are provided by Simrad readily set up with a fixed Ethernet address and an IP address If your EK15 uses two or more transceivers these will by default have different Ethernet addresses but identical IP addresses In order for your system to work all transceivers must have unique IP addresses If you have bought complete EK15 system that includes a computer and the required number of transceivers this configuration was done at the factory However if you have purchased your own computer and adds additional transceivers to an existing system you must do this yourself or leave it to your dealer 1 Click the Setup icon This icon is located under the Main menu It is used to open the Setup menu A 2 Click the Installation button to open the Installation menu Installation On the menu click Transceiver Installation to open the Transceiver Installation dialog lt lt Transceiver Installation The purpose of the Transceiver Installation dialog is to set up the necessary parameters to connect the EK15 computer to the transceiver s and the transducer s 3 Observe that the current frequency channels are listed in the dialog Click once on the frequency channel you wish to modify Observe that the relevant transceiver parameters are shown in the Transce
11. cy channel The upper part of the Transceiver Installation dialog displays a list of frequency channels which either are or have been installed on the EK15 For each channel on the list a Status label is provided The following status values are available in the Transceiver Installation dialog Busy The frequency channel is already in use probably by another echo sounder on the same network You can not connect to this channel e Installed This frequency channel is connected to your EK15 system e Lost This frequency channel can not be used e Available This frequency channel is vacant and ready for use 351719 A 19 Simrad EK15 20 Procedure a f S Click the Setup icon This icon is located under the Main menu It is used to open the Setup menu Click the Installation button to open the Installation menu Installation On the menu click Transceiver Installation to open the Transceiver Installation dialog lt lt Transceiver Installation The purpose of the Transceiver Installation dialog is to set up the necessary parameters to connect the EK15 computer to the transceiver s and the transducer s In the Transceiver Installation dialog click Browse The EK15 will automatically search the network for transceivers Observe that all the frequency channels are listed in the dialog Select a frequency channel that is available and choose the correct transducer in the spin box
12. dress 22 IP address 22 outline dimensions drawing 40 42 351719 A Simrad EK15 43 351719 A ISBN 13 978 82 8066 147 0 2012 Kongsberg Maritime AS
13. e familiar with the Windows 7 operating system and conversant with network addressing and communication principles Installation instructions The instructions provided in this manual must be followed carefully to ensure optimal performance As a guide installation procedures are presented in the order they are to be performed The equipment described in this manual includes the complete system with relevant cabinets but not system units provided locally by the customer installation shipyard or local representative The manual also defines the equipment responsibility and provides applicable instructions for unpacking and storage Note The installation instructions given in this document must be adhered to Failure to do so may render the guarantee void Kongsberg Maritime AS will accept no responsibility for any damage or injury to the system vessel or personnel caused by equipment that has been incorrectly installed or maintained or by drawings instructions or procedures that have not been prepared by us 351719 A 5 Simrad EK15 Installation drawings Detailed vessel specific mechanical drawings for the installation must be provided by the customer or any shipyard contracted to perform the installation Kongsberg Maritime AS may on special order provide assistance to these drawings Drawings must be approved by the appropriate vessel certification authority prior to installation of the system Applicable outli
14. e provided with two Ethernet boards to interface with a local area network LAN You must then use one Ethernet board to communicate with the EK15 transceiver s and one to communicate with the LAN These two boards can and must be set up separately The Ethernet board used to communicate with the transceivers s must be set up with manual IP addresses The board used to communicate with the LAN must be set up to obtain an IP address automatically unless otherwise decided by your network administrator 18 351719 A Installation Procedure 1 On the computer define the network adapter settings Windows 7 a Click Start Control Panel Network Connections b Click Change adapter settings on the left menu c Click once on the network adapter to select it and click Properties on the short cut menu d Onthe list of connections click Internet Protocol 4 TCP IPv4 and then Properties e Click Use the following IP address and enter the IP address and network mask IP Address 157 237 14 60 Subnet mask 255 255 255 0 f Click OK to save the settings g Exit all dialogs On the computer start the EK15 program Set up the transceiver s and transducer s This procedure explains how to install a frequency channel Important You must have a valid software license on your EK15 computer to set up a frequency channel Each EK15 transceiver with its transducer and single frequency is referred to as a frequen
15. em description PS vaca neseenenetiarenn ir cunresvsan incansan Sac aeann eee ata canst beretetulmenanetene 8 System dia pt sss ccvasspusdcovssnsnessoansvddcswadietecpnaddutecenadisievemadiaedesnsdcedesspasekiessaniaedabsaawee 9 SyStEM MINIS ere nn E E E E E 10 Colour display ss nn adetnncesadt snctet ocbdweescbeddonte seed Voce saed coties sathenads atbends 10 CoOMp t T asia es sente sante tete dant e tan etes dde dan ete taie nee 10 Transceiyer Unit eere oE EE EA E aE iE 11 EK15 TransQucer iiini e E E A R EN ANER 11 Ethernet SMIC ee a E ETO EEE EEEE 11 COIS OF S PPly ssl EEE REE 12 Network SCC a een EEEE E ATES 12 Support HOTMAIL emmener nee 13 INSTALLATION ssssssnssssmasnmssnnsnmsnmenmnmisnicnminiasnces 15 Installation of the system VOIS mi masses liens 16 Installation of the EK15 SOIN ARS RE SN audi 16 Obtaining the software H nin etes 17 Setting up the EK15 transceiver s for the first time 18 Installing a frequency chafn lsssssssssss enssnsinnnnnnnnssntieennssises 21 Changing the IP addresses when more than one transceiver is used 22 CABLE LAYOUT AND INTERCONNECTIONS mmnnn 24 Cable planene en ire intenses 25 LAS CO PCA mn nl et enin 26 Cable RSS a a a a biais 28 AC mains IEC G09 20 PE IT 29 RJ45 Ethernet straight cccceseseseseeesenencansnecececeaeaeeceeeceeeeeeeeeeeeeeeeneeeees 30 Transceiver Unit connections 32 TECHNICAL SPECIFICATIO
16. erational frequency is 200 kHz which offers a very high resolution and high accuracy You can use the Simrad EK15 with up to 15 Transceiver Units These will operate in parallel with either simultaneous or sequential pinging Using multiple transceivers you can monitor large areas with only a single echo sounder system 8 351719 A Simrad EK15 System diagram A typical EK15 system diagram with four transceivers is provided Interface capabilities power supplies and power cables are not shown Figure 1 Typical system diagram with a number of transceivers CD010300 001 a a ee a a a ee ee Display Unit Processor Unit personal computer Ethernet switch Transceiver Unit SO gt Transducer To control the EK15 operation you can use a standard commercial computer even a laptop The EK15 application supports Windows 7 operating system On a larger system with multiple transceivers we recommend using a large display in order to the view all echograms simultaneously You can connect up to 15 transceivers to the computer by means of a commercial Ethernet switch If you only need one transceiver the switch is not required Each transceiver is provided with a dedicated power supply for AC operation The only communication between the transceivers and the Ethernet switch or computer is the Ethernet cable Due to the amount of information only high quality Ethernet cables can be used The cables may be easily replaced by commer
17. escription 351603 EK15 Echo sounder module Pompe SSCS EF isy SSCSCSCSSCC C r EE EE O ETES Network security Equipment manufactured by Kongsberg Maritime are frequently connected to the ship s local area network Connecting any personal computer to a network will always expose the data on that computer to all other computers connected to the network Several threats may immediately occur e Remote computers can read the data e Remote computers can change the data e Remote computers can change the behaviour of the computer for example by installing unwanted software Usually two parameters are used to define the threat level e The likelihood that any remote connection will do any of the above e The damage done if a remote connection succeeds doing this Because Kongsberg Maritime has no information regarding the complete system installation on any vessel we can not estimate the threat level and the need for network security For this reason we can not accept responsibility for network security Systems 12 351719 A Simrad EK15 provided by Kongsberg Maritime are regarded as stand alone systems even though they may be connected to a network for sensor interfaces and or data distribution For this reason no safety applications are installed on any computers to protect these against viruses malware or unintentional access by external users Securing the EK15 itself has no meaning unless there is a policy in place that
18. he computer is not a part of the Simrad EK15 scope of supply Refer to the documentation provided by the manufacturer Transceiver Unit e Supply voltage 12 Vdc e Power consumption 1 2 W e AC power supply Included with delivery 351719 A 35 Simrad EK15 Minimum computer requirements Observe the minimum technical requirements for the Simrad EK15 Processor Unit computer Unless specifically ordered from Simrad the EK15 is not provided with a colour display or computer These items must be purchased locally If more than one Transceiver Unit is used a high speed Ethernet switch is also required It is important to make sure that the chosen computer model meets the technical system requirements It must fulfill the various interface requirements made by the EK15 system and you may need to add extra Ethernet and serial adapters Make sure that the computer design and construction allow for marine use easy access to parts and cables and a safe installation A laptop computer may be used as long as it meets the technical requirements The minimum requirements are e Processor 2 GHz Dual core e Memory capacity 2 Gb e Hard disk capacity Minimum 30 Gb free If you wish to record raw data you must either install a large hard disk or relay on peripheral storage devices e Graphic adapter The graphic adapter must support DirectX9 0c and must be compatible with Direct3d and OpenGL A large number of commercial graphic ad
19. ht on page 30 Important If you for any reason wish to use your own Ethernet cable it is very important that a high quality cable is used You must use CAT 5E quality or better Cables with lower bandwidth capacity will reduce the EK15 performance Transducer cable This cable is provided with the transducer The length is 25 meters and it is terminated with a plug that fits the socket on the Transceiver Unit Transceiver Unit connections on page 32 Power cable This cable is provided with the power supply It is terminated with a plug that fits the socket on the Transceiver Unit Transceiver Unit connections on page 32 AC mains to power supply This cable is provided with the power supply It is a standard commercial mains cable The power supply end is permanently fixed to the supply The other end is terminated in an AC connector suitable for the local conditions If this is not the case you must replace the AC connector The typical cable length is between 1 5 and 2 meters If this is too short you must use an extension cable not recommended mount a new power outlet within range or make your own power cable AC mains IEC 60320 on page 29 This cable is provided with the power supply It is terminated with a standard mains plug Not used Ethernet cable from computer to external network If your computer is fitted with two Ethernet adapters you can connect it to an external network This is a high
20. ideo output formats provided by the computer e Physical size Depends on personal and operational preferences The EK15 software supports 9 16 displays Tip If you use the EK15 with many transceivers you may find it useful with a large high resolution display 351719 A 37 Simrad EK15 Drawing file This chapter contains relevant drawings related to the installation and maintenance of the Simrad EK15 The mechanical drawings are for information and guidance only They are not in scale All dimensions are in mm unless otherwise is noted The original installation drawings are available on PDF and or AutoCad s DWG format Visit www simrad com to download Topics e Transducer outline dimensions on page 39 e Transceiver outline dimensions on page 40 38 351719 A Drawing file Transducer outline dimensions This transducer is not designed for hull mounting R1 1 8 237 89 Recommended cutout 240 0 1 0 05 All measurements in mm 367914 Rev A The drawing is not in scale CD010301 001 351719 A 39 Simrad EK15 Transceiver outline dimensions SUUIRYA D All measurements in mm 358598 Rev A The drawing is not in scale CD010302 001 40 351719 A 1000Base T 30 A AC mains cable 230 Vac 29 C Cable 230 Vac 29 ethernet straight 30 power 32 transduce
21. iver Information field 6 Set the transducer s to None and click Apply 22 351719 A Installation 7 Click Change IP Address to open the IP Address dialog Note If you have two Ethernet cables connected to your computer you may need to disconnect the Ethernet cable to the ship s network before the Change IP Address is available 8 Enter a new IP address Tip Change only the last digit in the IP address Tip If you do not have a computer keyboard connected to your EK15 system click the Keyboard button to open an on screen keyboard 9 Click OK to save the current settings and close the dialog 10 In the Transceiver Installation dialog observe that the IP address for the chosen transceiver has changed 11 Install the transducers for the channel with the new IP address Note Make sure that you choose the correct transducer s 12 Click OK to save the current settings and close the dialog 351719 A 23 Simrad EK15 Cable layout and interconnections This chapter provides the cable plan and cable installation requirements for the Simrad EK15 Topics e Cable plan on page 25 e List of cables on page 26 e Cable drawings on page 28 24 351719 A Cable layout and interconnections Cable plan Observe the cable plan for the Simrad EK15 Cables identified with an asterix are provided by Simrad fo O C06
22. les 24 Introduction Simrad EK 15 7 IP address change 22 IP Address Ethernet board in computer 19 IP address transceiver 22 L License obtain 17 List cables 26 M Main units 10 Mains cable 230 Vac 29 Mechanical drawings 38 Minimum requirements computer 36 display 37 Mode choose Normal 20 N Normal operational mode choose 20 O Operational mode choose Normal 20 Options functionality 12 system units 12 Outline dimensions drawings 38 P Parts delivered 12 Procedure basic system installation 16 change IP address 22 channel installation 19 21 41 Simrad EK15 choose Normal Transceiver Unit operational mode description 11 20 Transducer echogram channel outline dimensions installation 19 21 drawing 39 EK15 software installation 16 frequency channel U one ee Units initial start up in 1 obtain EK15 software ii license 17 R Registered trademarks 6 Requirements computer 36 display 37 RJ45 plug 30 S Scope of supply 12 Simrad EK15 familiarization 7 introduction 7 main units 10 Software installation 16 Software license obtain 17 Start up procedure initial 18 Start up procedures 15 Subnet mask Ethernet board in computer 19 System description 8 diagram 9 System installation basic 16 System units 10 T T 568B 30 Technical requirements computer 36 display 37 Trademarks 6 Transceiver Ethernet ad
23. nd threat levels the end user has defined for the complete installation For some products the network consists of only processor units or work stations transceivers and a few sensors On other vessels larger computer systems can be installed to include numerous products and data systems As the DNV OS D203 suggests there must be one responsible person for the security of a system large or small Support information If you need technical support for your Simrad EK15 you must contact your local dealer or one of our support departments A list of all our dealers is provided on http www simrad com 351719 A 13 Simrad EK15 Norway Main office Company name Kongsberg Maritime AS Simrad Address Strandpromenaden 50 3190 Horten Norway Telephone 47 33 03 40 00 Telefax 47 33 04 29 87 E mail address simrad support simrad com Website http www simrad no Spain Company name Simrad Spain Address Poligono Partida Torres 38 03570 Villajoyosa Spain Telephone 34 966 810 149 Telefax 34 966 852 304 E mail address simrad spain simrad com Website http www simrad es USA Company name Kongsberg Underwater Technology Inc Simrad Fisheries Address 19210 33rd Ave W Lynnwood WA 98036 USA Telephone 1 425 712 1136 Telefax 1 425 712 1193 E mail address simrad usa simrad com Website http www simrad com Malaysia 14 Company name Kongsberg Maritime Malaysia Sdn Bhd Address U
24. ne dimension and productions drawings are provided in the Drawing file chapter Drawings may also be downloaded in PDF and or DWG formats from http www simrad com Registered trademarks Windows Windows XP and Windows 7 are either registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries Simrad SIMRAD and the Simrad logo are either registered trademarks or trademarks of Kongsberg Maritime AS in Norway and other countries 6 351719 A Simrad Study this chapter to familiarize yourself with the Simrad EK15 Topics System description on page 8 System diagram on page 9 System units on page 10 Scope of supply on page 12 Network security on page 12 Support information on page 13 351719 A Simrad EK15 EK15 Simrad EK15 System description The Simrad EK15 is designed for a variety of applications and for both mobile surveys and fixed locations You can put it to use in a wide variety of environments lakes fjords harbours shallow marine rivers and even in aquaculture fish cages The unique functionality offered using numerous transceivers raw data logging and interfaces to secondary systems allow you to use the EK15 for fish stock assessment studies of fish behavior and fish plankton interactions habitat mapping and ecosystem monitoring The Simrad EK15 is based on a small and ruggedized single beam Transceiver Unit and a dedicated transducer The op
25. nit 27 5 Signature Offices The Boulevard Mid Valley City Lingkaran Syed Putra 59200 Kuala Lumpur Malaysia Telephone 65 6411 7488 Telefax 60 3 2201 3359 E mail address simrad asia simrad com Website http www simrad com 351719 A Installation Installation These are the specific procedures required to get you started with the Simrad EK15 Normally you will only need to do these procedures once We recommend that you allow your dealer with the assistance from a shipyard to do the physical installation install the software obtain a valid license and get you started Topics Installation of the system units on page 16 Installation of the EK15 software on page 16 Obtaining the software license on page 17 Setting up the EK15 transceiver s for the first time on page 18 Installing a frequency channel on page 21 Changing the IP addresses when more than one transceiver is used on page 22 351719 A 15 Simrad EK15 Installation of the system units This procedure explains the basic principles of EK15 installation It does not provide any details related to physical installation of the various units location and installation of the transducer s and the various interface parameters All documentation for the Simrad EK15 is located on the media device provided with the delivery The documents can also be downloaded from http www simrad com WARNING The Simrad EK15 transducer is not designed for hull moun
26. on 2 Observe the Main menu It is normally located on the right hand side of the EK15 presentation 351719 A 17 Simrad EK15 3 Click the Setup icon This icon is located under the Main menu It is used to open the Setup menu A 4 Click Installation to open the Installation sub menu Installation On the sub menu click Software License to open the Software License dialog lt lt Software License The purpose of the Software License dialog is to allow you to enter a license code text string to unlock the EK15 functionality In order to obtain the license code s required contact your dealer 5 Write down the Hardware ID provided by the Software License dialog 6 Contact your dealer to order the software license Your dealer will need the following information from you to place the order e Vessel name and call sign e Vessel type trawler purse seiner etc e Vessel owner s name address and contact information e Serial number on all transceivers e Hardware ID 7 When the software license is returned to you start the EK15 open the Software License dialog and click Enter Licence String 8 Write down the code and click Ok 9 Click OK to save the current settings and close the dialog Setting up the EK15 transceiver s for the first time This procedure explains how to set up you computer to communicate with the transceiver You only need to do this once Important Your computer may b
27. r 32 Cable drawings 28 Cable layout 24 Cable list 26 Cable plan 25 Cables 24 Cabling cable list 26 cable plan 25 drawings 28 CAT SE 27 Colour display description 10 minimum requirements 37 minimum specifications 10 Computer minimum requirements 36 Computer Ethernet board IP Address 19 Subnet mask 19 D Description system 8 Diagram system 9 Display minimum requirements 37 Drawing Cable plan 25 system 9 Transceiver 40 Transducer 39 Drawings 38 cables 28 installation 6 E Echogram channel how to install 19 21 EK15 351719 A Index cable layout 24 familiarization 7 introduction 7 main units 10 EK15 installation basic 16 EK15 Transceiver outline dimensions drawing 40 EK15 Transducer outline dimensions drawing 39 Ethernet straight cable 30 Ethernet board computer IP Address 19 Subnet mask 19 Ethernet cable 27 Ethernet address transceiver 22 F Familiarization Simrad EK 15 7 Frequency channel installation 19 21 H How to basic system installation 16 change IP address 22 choose Normal operational mode 20 initial start up 18 install channel 19 21 install EK15 software 16 install frequency channel 19 21 obtain EK15 software license 17 I IEC plug 29 IEEE 802 3ab 30 Initial start up procedure 18 Installation basic 16 drawings 38 procedures 15 software 16 Installation drawings 6 Index Interconnection cab
28. rent lengths colours and categories 10Base T Low speed Ethernet connections HUB White Orange a Rx Data Rx Data Tx Data Tx Data Tx Data Rx Data Orange Green White a a Blue White Blue p i Green ON ol oO eA w N Rx Data Tx Data White Brown i Brown W403 o 7 Ethernet Straight Through T 568B Cable specifications l Nl lo lal S oo N a e Not applicable This is a commercial cable 30 351719 A 1000Base T High speed Ethernet connections CATSE and faster PC Cable layout and interconnections HUB Bi directional A White Orange SE Bi directional A Bi directional A Orange Bi directional A Bi directional B Green White Bi directional B Blue Bi directional C Bi directional C Bi directional C White Blue a EE _ Bi directional C Bi directional B Green Bi directional B Bi directional D White Brown a rr Bi directional D CO IN 19 O1 BR IN CO IN OO O1 BR IN Brown Bi directional D Bi directional D W403 Rev C Cable specifications Ethernet Straight Through 1000Base T IEEE 8
29. ructions provided Note In the last dialog you are permitted to remove old settings If you click to do this the installation wizard will delete all settings related to the physical installation These include all interface parameters and all transceiver settings Only software licenses are kept 6 Once the installation has been completed double click the program icon on the desktop to start the application 7 Ifyou use Windows 7 operating system a Observe that Windows 7 Firewall will open a dialog requesting information about the network Select Public and click Allow access b The operating system may also open other dialogs to verify that the EK15 software can run on the computer You must permit this 8 Observe the relevant start up procedure Related topics e Setting up the EK15 transceiver s for the first time on page 18 Obtaining the software license The EK15 requires a valid license to operate This procedure explains how to obtain a license and how to install it on your EK15 computer Without a license you will not be able to communicate with the EK15 Transceiver Unit s Note If you replace your computer or if you replace major components inside your computer you will need a new license code We strongly advice you to record the license code for safe keeping You may for example write it down in the beginning of this manual 1 Double click the EK15 icon on the desktop to start the applicati
30. se you must replace the AC connector The typical cable length is between 1 5 and 2 meters If this is too short you must use an extension cable not recommended mount a new power outlet within range or make your own power cable AC mains IEC 60320 on page 29 Display video cable This video cable is normally provided with the display and it is often physically attached to the rear side of the display It is a standard commercial cable The most common video formats and connectors are SVGA and DVI Some computers also support the HDMI output format Make sure that the computer s graphic adapter is fitted with a connector that matches the video cable provided with the display Computer keyboard This is a standard keyboard cable It is usually fixed to the keyboard The connection normally depends on the make and model of the computer Most recent computers use a USB plug older types use PS 2 Wireless keyboards are also available Note that the keyboard is an optional item It is not a part of the EK15 delivery Computer mouse This is a standard computer mouse or other pointing device cable It is physically attached to the mouse The cable is normally terminated in a USB plug Wireless pointing devices are also available 351719 A C6 C7 C8 C9 C10 C11 C12 Cable layout and interconnections Ethernet cable from computer to Transceiver Unit This is a high quality Ethernet cable RJ45 Ethernet straig
31. secures all computers in the network including physical access by trained and trusted users This must always be a task for the end user to implement The EK15 system has been verified to run under rather strict security setup so it should be possible to implement a good security regime If you wish to connect the EK15 to the ship s network you must implement the same security mechanisms on the EK15 computer s as for the rest of the network In the tentative standard from Det Norske Veritas DNV Integrated Software Dependent System DNV OS D203 this is described as a task for the network responsible person in charge of the overall behaviour of the network system Some key elements here must be e The same anti virus protection on all computers including routines for updating this protection e The same settings for the firewall on all computers e Controlled physical access to computers on the network e Trusted operators e Log in access mechanisms e Same policy for attaching peripheral equipment to the computers USB devices hard drives etc e Installation of programs on any computer in the network verification that each program is authentic e Definition of which programs are allowed to run on each computer e Logging mechanism of computer activity and inspection of these logs How to define and implement these rules depends on each end user s network system configuration which again must be a result of the policies a
32. single beam calibration Data output formats e Raw data EK60 format e Processed data e Raw data storage capacity only limited by disk size Data subscriptions Ethernet datagram based system for remote subscription Third party post processing e EchoView e Sonar5 Transducer e Type Single beam e Maximum installation depth 600 meters e Beamwidth 26 degrees 34 351719 A Technical specifications Weights and outline dimensions This section provides the technical specifications and requirements related to weight and outline dimensions For more detailed information about the dimensions refer to chapter Drawing file e Drawing file on page 38 Colour display e The colour display is not a part of the Simrad EK15 scope of supply Refer to the documentation provided by the manufacturer Computer e The computer is not a part of the Simrad EK15 scope of supply Refer to the documentation provided by the manufacturer Transceiver Unit e Width 10 cm e Height 15 cm e Depth 6 cm Transducer e Diameter 40 mm e Height 55 mm e Cable length 25 mm e Limitations The transducer is not designed for hull mounting Power specifications This section provides the technical specifications and requirements related to the AC and or DC mains supply Colour display e The colour display is not a part of the Simrad EK15 scope of supply Refer to the documentation provided by the manufacturer Computer e T
33. sounder on the same network You can not connect to this channel e Installed This frequency channel is connected to your EK15 system e Lost This frequency channel can not be used e Available This frequency channel is vacant and ready for use Procedure 1 Click the Setup icon This icon is located under the Main menu It is used to open the Setup menu A 2 Click the Installation button to open the Installation menu Installation On the menu click Transceiver Installation to open the Transceiver Installation dialog lt lt Transceiver Installation The purpose of the Transceiver Installation dialog is to set up the necessary parameters to connect the EK15 computer to the transceiver s and the transducer s 3 Inthe Transceiver Installation dialog click Browse The EK15 will automatically search the network for transceivers 4 Observe that all the frequency channels are listed in the dialog 351719 A 21 Simrad EK15 5 Select a frequency channel that is available and choose the correct transducer in the spin box Note This is a critical task You must ensure that the correct transducer is selected If you connect the transceiver to a transducer that can not handle the power rating it may be damaged beyond repair On the EK15 always choose transducer ES10 6 Observe that the status for the relevant frequency channels changes to nstalled 7 Click OK to save the current settings and
34. ting Procedure 1 Install the various hardware units transceiver s computer s and transducer s 2 Connect all necessary cables between the hardware units a Connect the transducer s to the transceiver s b Connect power to the transceiver s c Connect the Ethernet cable from each transceiver to the Ethernet switch and one Ethernet cable from the switch to the computer d Connect the necessary cables to the display power and video 3 Do a close visual inspection of the installation Check each cable and connection to ensure that all wiring is correct 4 Power up the EK15 and proceed with the next procedure software installation Related topics e Installation of the EK15 software on page 16 e Cable layout and interconnections on page 24 e Drawing file on page 38 Installation of the EK15 software Use this procedure when you wish to install the EK15 software on a computer Note Note that minimum hardware and software requirements must be met by the computer Procedure 1 Power up the computer 2 Insert the EK15 software media If the EK15 software is provided on a CD or DVD and your computer is not fitted with a suitable drive copy the files from the CD DVD to a USB memory stick 3 Use a file manager application on the computer to access the software 4 Double click on the Setup exe file to start the installation 16 351719 A Installation 5 Allow the installation program to run Follow the inst
35. without the prior written consent of Kongsberg Maritime AS The document or any part of it may not be translated to any other language without the written approval from Kongsberg Maritime AS Disclaimer Kongsberg Maritime AS endeavours to ensure that all information in this document is correct and fairly stated but does not accept liability for any errors or omissions Warning The equipment to which this manual applies must only be used for the purpose for which it was designed Improper use or maintenance may cause damage to the equipment and or injury to personnel All users must be familiar with the contents of the appropriate manuals before attempting to install operate maintain or in any other way work on the equipment Kongsberg Maritime AS disclaims any responsibility for damage or injury caused by improper installation use or maintenance of the equipment Support information If you require maintenance or repair contact your local dealer You can also contact us using the following address simrad support simrad com If you need information about our other products visit http www simrad com On this website you will also find a list of our dealers and distributors See also Support information on page 13 Kongsberg Maritime AS www kongsberg com Installation manual Table of contents ABOUT THIS MANUAL ccccccccccccccccccccccccccccccccccceeeeneneeeeenens 5 SIMRAD EK15 sisssissmiomenmaonmmmmmammionmomiosnt 7 Syst