1. CP 21TC User Manual Please read the instructions carefully before use Innovation Quality Performance TABLE OF CONTENTS 1 Safety Instructions 2 Technical Specifications 3 How To Set The Fixture 4 How To Control The Fixture 5 DMX 512 Configuration 6 DMX 512 Connections 7 Troubleshooting 8 Fixture Cleaning 1 Safety Introductions A N Please read the instructions carefully which includes important information about the installation operation and maintenance WARNING Please keep this User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet All fixtures are intact from the manufacturer please operate follow up the user manual artificial fault are not under guarantee repair Unpack and check carefully that there is no transportation damage before using the unit The unit is for indoor use only Use only in a dry location Do install and operate by operator Use safety chain when fixes the unit Don t handle the unit by taking its head only but always by taking its base The unit must be installed in a location with adequate ventilation at least 50cm from adjacent surfaces Be sure that no ventilation slots are blocked otherwise the unit will be overheated Before operating ensure that the voltage and frequency of power supply match the power requirements of the unit It s important to ground the yellow green conducto
2. 1 or Gh el Show 2 o show 5 o color or fade if you select the color or fade en press ENTER button to confirm and use DOWN and UP button to select color 1 9 or fade speed speed 1 slow speed 2 middle speed 3 fast Once select press ENTER button to setup or automatically exit menu mode without any change after one minute To go back to the last function without any change press the MENU button 8 Press the MENU button up to when the is shown on the display Pressing ENTER button Use DOWN and UP button to select the Sound on or sound off Once select press ENTER button to setup or automatically exit menu mode without any change after one minute To go back to the functions without any change press the MENU button rr Blackout mode Press the MENU button up to when the bial is shown on the display Pressing ENTER button Use DOWN and UP button to select the blackout or Ino normal Once select press ENTER button to setup or automatically exit menu mode without any change after one minute To go back to the functions without any change press the MENU button Manual setting color Press the MENU button up to when the l is shown on the SS i ENTER button and use DOWN and UP button to select Fed strobe press ENTER button to confirm and use DOWN and UP button to adjust the value once select press ENTER button to setup or automatically exit menu mode without any change after one minu
3. 20 232 Color 29 248 255 Open 217 224 Color 28 210 216 Color 27 240 247 Random Strobe 202 209 Color 26 9 0 Mains output Connect to supply mains power for the next unit 194 201 Color 25 z 186 193 Color 24 232 239 Open 179 185 Color 23 191 2314 Slow Close Iri ae Sse 22 Fast Open 163 olor 21 155 162 Calor 20 182 190 Open olor 1 140 147 Color 18 140 1819 Slow Open 132 138 Color 17 124 1371 Color 16 a 117 123 Color 15 132 139 j Open Mains input Connect to mains AC Safety Ring Keep the installation safe 109 116 Color 14 l 101 108 Color 13 StF 093 100 Color 12 086 092 Color 11 078 085 Color 10 i i 070 077 Color 9 To select any functions press MENU button until the required one is shown on the display 062 069 Color 8 055 061 Color 7 Select the function by ENTER button and the display will blink Use DOWN and UP button to 047 054 Color amp 031 038 Color 4 change the mode Once the required mode has been selected press ENTER button to olor eee otor setup or it will automatically return to the main functions without any change after idling one 000 007 OFF minute Back to the functions without any change press MENU button The main functions kea creen Bue 8RR i 255 255m 100 255 255 gt jase eee ade 161 255 P 128 199 0 127 0 o 7 13 6 Mid DMA512 Addre Setti Addr ress Setting rec Oa g duto Auto DMX address se
4. a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be fixed by professionals And it must be fixed at a place where is out of the touch of people and has no one pass by or under it 2 Technical Specifications e Voltage 100 240V 50 60Hz at e LED 3W Tri Color x 21pcs T ma o 4 fim Ow e Fuse T 6 3A i ap g an e Power consumption 85W N 4 ry ek e Dimension 162 x 185 x 248mm 185 141 e Weight 4 1kgs u16 3 How To Set The Fixture 3 1 Control Panel Display To show the various menus and the selected functions 2 LED DMX On DMX input present MASTER On Master Mode Flashing Sound activation 6 DMX512 Connections The DMX512 is widely used in intelligent lighting control with a maximum of 512 channels DMX controller COMMON a kN i a i aj 1 jy 1s i DMX INPUT 3 a 3 DMX OUTPUT ae DMX en es EA TA kodikas signal errors and to avoid signal ae transmission problems and interference It is always i 38 a advisable to connect a DMX terminal AL AN Resistance 120 ohm 1 4W between pin2 DMxX and pin3 DMA of the last fixture 1 Connect the fixture together in a daisy chain by XLR plug cable from the output of the fixture to the input of the next fixture The cable cannot be branched or split to a Y cable Inadequate or damaged
5. cables soldered joints or corroded connectors can easily distort the signal and shut down the system 2 The DMX output and input connectors are pass through to maintain the DMX circuit when one of the units power is disconnected 3 At last fixture the DMX cable has to be terminated with a terminator to reduce signal errors Solder a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a 3 pin XLR plug and plug it in the DMX output of the last fixture 4 Each lighting fixture needs to have an address set to receive the data sent by the controller The address number is between 0 511 usually O amp 1 are equal to 1 5 3 pin XLR connectors are more popular than 5 pins XLR 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 5 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal Pin4 5 not used 7 Troubleshootino Following are a few common problems that may occur during operation Here are some suggestions for easy troubleshooting Mode 3 amp 48 amp 5 Microphone Receive music for the sound active DMX512 Configuration Only for remote control By connect to the 1 4 microphone jack to control the unit for Stand by Function and Mode function DMX output For DMX512 link use 3 pin XLR plug cable to link the next unit 248 255 Color 32 241 247 Color 31 sige aes sp Sta oi Cuan ne DMX input For DMX512 link use 3 5 pin XLR plug cable to input DMX signal 2
6. en the rhe is blinking on the display Pressing ENTER button and the display will show the number of working hours of the unit To go back to the functions press the MENU button Lil Software version Press the MENU button up to when the Ler is blinking on the display Pressing ENTER button and the display will show the version of software of the unit To go back to the functions press the MENU button again 4 How To Control The Unit You can operate the unit in three ways 1 By master slave built in preprogram function 2 By easy controller 3 By DMX controller No need to turn the unit off when you change the DMX address as new DMX address setting will be effected at once Every time you turn the unit on it will show CP21 on the display and move all the motors to their home position After that the unit will be ready to receive DMX signal or run the built in programs 10
7. hange after one minute Back to the previous functions without any change press MENU button g L Ic m Auto DMX address setting Press the MENU button up to when the duto is blinking on the display Pressing ENTER button and the DMX address of the fixture can be set automatically by built in program To go back to the functions press the MENU button again rer Limi Channel Mode Press the MENU button up to when the LANG is shown on the display har iii button and the pA ul blink Use DOWN and wad R to select the a channels mode or z 3 channels mode 4 channels mode or Te m 4 channels mode mode Once the mode has been selected press the ENTER button to setup or automatically exit menu mode without any change after one minute To go back to the functions without any change press the MENU button I W Press the MENU button up to when the l2 110 is showing on the display Pressing ENTER paced a the a will blink Use DOWN and UP button to select the normal 2 slave 2 or or Si 16 16 light show mode Once the mode has been or selected press the ENTER button to setup or automatically return to the main functions without any change after one minute To go back to the functions without any change press the MENU button again 5 nm i d Show Mode Press the MENU button up to when the SAd is shown on the display Pressing ENTER button Use DOWN and UP n to oe the Random show or ah show
8. heck DMX connectors cables to see if link properly N gt Wry Bb If the DMX LED is on and no response to the channel check the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on connectors or on PCB of the fixture or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C Some fixtures don t respond to the easy controller 1 You may have a break in the DMX cabling Check the LED for the response of the master slave mode signal Wrong DMX address in the fixture Set the proper address No response to the sound Make sure the fixture does not receive DMX signal 2 D 1 2 Check microphone to see if it is good by tapping the microphone E One of the channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition 8 Fixture Cleaning The cleaning of internal must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture s optics e Clean with soft cloth using normal glass cleaning fluid e Always dry the parts carefully e Clean the external
9. optics at least every 20 days Clean the internal optics at least every 30 60 days 15 e Do not allow children to operate the fixture e Do not touch any wire during operation as there might be a hazard of electric shock e Avoid power wires together arounding other cables e Disconnect mains power before fuse lamp replacement or servicing e Replace fuse only with the same type e Inthe event of serious operating problem stop using the unit immediately e Never turn on and off the unit time after time e The housing the lenses or the ultraviolet filter must be replaced if they are visibly damaged e Do not open the unit as there are no user serviceable parts inside e Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center e Disconnect the mains power if the fixture is not used for a long time e Do use original packing materials once transport it again e Do not look directly at the LED light beam while the fixture is on For power supply do not connect in series much more than 7 units use another mains supply for next 7 units Installation The unit should be mounted via its screw holes on the bracket Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating Always ensure that the structure to which you are attaching the unit is secure and is able to support
10. r to earth in order to avoid electric shock Maximum ambient temperature TA 40 C Don t operate it where the temperature is higher than this Don t connect the device to any dimmer pack First run there will be smoke or smells and all disappearing a few minutes later Make sure there are no flammable materials close to the unit while operating as it is fire hazard Look over power wires carefully replace immediately if there is any damage Never run on for a long time lest shortening lifespan Avoid any inflammable liquids water or metal objects entering the unit Once it happen cut off the mains power immediately Do not operate in dirty and dusty environment also cleaning fixtures regularly 3 EC Declaration of Conformity We declare that our products lighting equipments comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 11 1994 amp Harmonized Standard EN60598 1 2000 ALL 2000 A12 2002 Safety of household and similar electrical appliances Part 1 General requirements The fixture does not work no light Check the connection of power and main fuse Measure the mains voltage on the main connector Not responding to DMX controller DMX LED should be on If not c
11. te To go back to the last function without any change press the MENU button White Balance Press the MENU button up to when the 2 Ol is shown on the pa A ENTER button and use DOWN and UP button to select Fed button to confirm and use DOWN and UP button to adjust the value between 125 and 255 mi once select press ENTER button to setup or automatically exit menu mode without any change after one minute To go back to the last function without any change press the MENU button LED display Press the MENU button up to when the Led is shown on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select display 9 always on or oF Eldisplay off 20 seconds after exit menu mode Once select press ENTER button to setup or exit menu mode without any change after one minute Back to the functions without any change press MENU button again it I Display Inverse Press MENU button until ct SF is on the display Use DOWN and UP button to select na display normal or display inverse press ENTER button to setup Back to the functions without any change press MENU button Lond I l Temperature Test Press the MENU button up to when the t ene is blinking on the display Pressing ENTER button and the display will show the temperature of the unit To go back to the functions press the MENU button again Cut F M 5 Fixture Hours Press the MENU button up to wh
12. tting D Channel mode a cool m Slave mode ala sf Si to Random Show Ea i i 5 Show 1 5 Color 1 9 FASD HHSP A Fade dr m coin Sound Mode on 4 FFE Sound Mode off rid HUG Blackout Mode Yes Blackout ae Uo Blackout Mode No Blackout ced Manu Manual mode btro botoctouere White balance Lue on LED on Led LED off mo Normal E di aP uoc Inversion Piel Temperature hr S Fixture Hours We Software Version DMX 512 Address Setting Press the MENU button up to when the is shown on the display Pressing ENTER button and the display will blink Use DOWN and UP button to change the DMX 512 address 7 the display stops blinking or storing automatically one minute later To go back to the functions without any change press the MENU button again If you use please refer to the following diagram to address your DMX512 channel for the first 4 units Mode 1 amp 2 DMX512 Configuration 255r 100 255r 100 g 0 i E 0 4 1 Master Slave Built In Preprogrammed Function The fixture will allow you to link 16 fixtures together and operate without a controller In Master Slave mode the first fixture whose DMX input jack has with nothing connect will be master automatically set other units to slave 1 or slave2 or slave 16 via menu then the first unit will control the others to give an automatic sound activated synchronized light show This function is good when
13. you want an instant show Any fixture can act as a Master or as a Slave 16 light show In slave mode slave 1 means the unit works as master slave 2 means 2 light show slave 3 means 3 light show and so on In order to create a great light show you can set the second unit to slave 2 to get contrast movement to each other even if you have two units only 4 2 Easy Controller by CA 8 _ s The easy remote control is used only in master slave mode By connecting to the 1 4 microphone jack of the first unit you will find that the remote controller f on the first unit will control all the other units for Stand by Function and Mode selection Blackout Blackout the unit Fade Speed 1 Slow 2 Middle 3 Fast 1 Strobe in white Select Function 2 Strobe in color color 1 9 3 Sound Strobe Sound Strobe Chase eee e LED OFF LED ON LED slow blinking LED fast blinking 4 3 DMX Controller Use universal DMX controller to control the units you have to set DMX address from 1 to 512 channel so that the units can receive DMX signal Press the MENU button up to when the Moor jg showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to change the DMX512 address Once the address has been selected press and keep ENTER button pressed up to when 11 Once the address has been selected press ENTER button to setup or automatically exit menu mode without any c