1. A Please read the instructions carefully which includes important information about the installation operation and maintenance Please keep this User Manual for future consultation If you sell the fixture to another user be sure that they also receive this instruction booklet Unpack and check carefully there is no transportation damage before using the fixture Before operating ensure that the voltage and frequency of power supply match the power requiremenis of the fixture Its important to ground the yellow green conductor to earth in order to avoid electric 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal shock 5 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal e Disconnect main power before servicing and maintenance e Use safety chain when fixes this fixture e Maximum ambient temperature is Ta 40 C Don t operate it where the temperature is 7 bl h ti higher than this TOLET ale e Inthe event of serious operating problem stop using the fixture immediately Never try Following are a few common problems that may occur during operation Here are some to repair the fixture by yourself Repairs carried out by unskilled people can lead to suggestions for easy troubleshooting damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts A The fixture does not work no light and the fan does not work e D
2. EC Declaration of Conformity We declare that our products lighting equipments comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 11 1994 amp Harmonized Standard EN60598 1 2000 ALL 2000 A12 2002 Safety of household and similar electrical appliances Part 1 General requirements Innovation Quality Performance 11B LED STROBE W LINKABLE SIT ast STAND ALONE LED 192 W User Manual Please read the instructions carefully before use TABLE OF CONTENTS 1 Safety Instructions 2 Technical Specifications 3 Main Function 4 How to control the fixture 5 DMX 512 Configuration 6 DMX 512 Connections 7 Troubleshooting 8 Fixture Cleaning C Some fixtures don t respond to the easy controller 1 You may have a break in the DMX cabling Check the LED for the response of the master slave mode signal 2 Wrong DMX address in the fixture Set the proper address D No response to the sound 1 Make sure the fixture does not receive DMX signal 2 Check microphone to see if it is good by tapping the microphone E One of the channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on
3. ack to the functions press the MENU button again l1 Ld l Software version Press the MENU button up to when the is blinking on the display Pressing ENTER button and the display will show the version of software of the unit To go back to the functions press the MENU button again 4 How to control the fixture Three ways to operation A Master Slave operation B Universal DMX controller C Easy controller CA 8 A Master Slave operation By linking the units in master slave connection the first unit will control the other units to give an automatic sound activated synchronized light show This function is good when you want an instant show You have to set the first unit in master mode Hasel Its DMX input jack will have nothing plugged into it and Its master LED will be constantly on and sound 6B
4. ing ENTER oe Use DOWN and UP buiton to select the Master Mode or or MENU button ri me Hon Sound Mode Press the MENU button until the is showing on the display Pressing ENTER button 4B and the display will blink Use DOWN and UP button to select the sound on or CL sound off mode Once the mode has been selected press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds To go back to the functions without any change press the MENU button again tri ALIU Blackout Mode Press the MENU button up to when the a oI ig showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select the 42S yes blackout or 1 no blackout mode Once the mode has been selected press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds To go back to the functions without any change press the MENU button again iri Ul Show Mode Press the MENU button up to when the Mich jg showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select the Muto Auto or W Menu mode Once the mode has been selected press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds To go back to the functions without any change pre
5. nked together as many as required in master slave mode and perform the great built in programmed lighting shows triggered by music e Please use a 3 pin XLR cable plug when connecting them together e It features different pre programmed chase patterns e Power supply Input Voltage AC 100V 240V 50 60Hz e Power consumption 18W e LED Total 192pcs White e Dimension 315mm x 181mm x 114mm e Weight 2 1KG egqscoeoeg oe o0e80 oo eooecdoeoe ocd oo ecooedcooeod0ds eooe ogo go oeo0ec9e o eooeo go 0000900 eoeoeodoeoeooed 6 eooeocgoeo oo ods eoogoe oc oo ego ee 9 eeoeo oeoece od eooeodoodooeccdso eo oe oc oceoec se oo eeoeo 920809008909 eeeoeeooeoeo0e 8 eooeoooo odo d eeogoeoeceoe 8S 8 Q o o o o Q o o o o o To select any functions press MENU button until the required one is shown on the display Select the function by ENTER button and the display will blink Use DOWN and UP button to change the mode Once the required mode has been selected press ENTER button to setup or it will automatically return to the main functions without any change after idling 10 seconds Back to the functions without any change press MENU button The main functions are shown below 3B 5 DMX512 Configuration Dimmer strobe 6 DMX512 Connections The DMX512 is widely used in intelligent lighting control with a maximum of 512 channels IN PUT OUT PUT COMMON INPUT Termination reduces
6. o not connect the device to any dimmer pack 1 Check the connection of power and main fuse e Do not touch any wire during operation and there might be a hazard of electric shock 2 Measure the mains voltage on the main connector e To prevent or reduce the risk of electrical shock or fire do not expose the fixture to rain B Not responding to DMX controller or moisture 1 DMX LED should be on If not check DMX connectors cables to see if link properly e The housing must be replaced if they are visibly damaged 2 If the DMX LED is on and no response to the channel check the address settings and e Do not look directly at the LED light beam while the fixture is on DMX polarity e There are no user serviceable parts inside the fixture Do not open the housing or 3 If you have intermittent DMX signal problems check the pins on connectors or on PCB attempt any repairs by yourself In the unlikely event your fixture may require service of the fixture or the previous one please contact your nearest dealer 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may For power supply do not connect in series much more than 33 units use cause damage or interference to DMX interface circuit another mains supply for next 33 units 9B 2B 2 Technical Specifications e t can be operated by DMX512 control or can be used as an individual unit without controller e It can be li
7. ontrol is used only in master slave mode There is a terminator for connect the easy controller inside the fixture By connecting the cable into DMX IN waterproof cable entry gland to the CA 8 terminator of the first fixture you will find that the remote control on the first fixture will control all the other fixtures for Stand by Function and Mode functions Blackout Blackout the unit Function 1 Synchronous Strobe Dimmer 2 Sound Strobe 3 Two light Strobe S Mode Sound Strobe LED ON e lt gt LED OFF NE itn My 7B oH EEF MASE Master Mode SUAIdH SL 1 Slave Mode 1 Ci E Slave Mode 2 cir Chol Sound On DMX512 Address Setting MIS Sound Off LEA Iniol_ Blackout Mode No Blackout MENU e eS Blackout Mode Yes Blackout em AEA LL abid EERE Lc Show Mode ii Led on Led off ep Display Normal LSA hoe dse Display Inversion FLI S Fixture Hours Ufl Ho ii Software Version DMX 512 Address Setting Press the MENU button up to when the cir is shown on the display Pressing ENTER button and the display will blink Use DOWN and UP button to change the DMX 512 address Once the address has been selected press ENTER button to setup or automatically return to the main functions without any change after 8 seconds Back to the previous functions without any change press MENU button Slave Mode Press the MENU button up to when the is shown on the display Press
8. signal errors and to avoid signal transmission problems and interference Itis always advisable to connect a DMX terminal Resistance 120 ohm 1 4W between pin2 DM and pin3 OMX of the last fixture 8B LED will flash to the music The other units will have to set in slave mode 2 c and select normal or 2 light show mode Their DMX cables plugged into the DMX input jacks daisy chain and the slave led lights will constantly on 2 light show mimo ut i In ttio slave mode means the unit works normally and means 2 light show In order to create a great light show you can set on the second unit to get contrast movement to each other even if you have two units only B Universal DMX controller If you use an universal DMX controller to control the units you have to set DMX address from 1 to 512 channel so that the units can i TECRIVE DMX signal Press the MENU button up to when the AAT ig shown on the display Pressing ENTER button and the display will blink Use DOWN and UP button to change the DMX512 address Once the address has been selected press and keep ENTER button pressed up to when the display stops blinking or storing automatically 8 seconds later To go back to the functions without any change press the MENU button again Please refer to the following diagram to address your DMX512 channel for the first 4 units FLITE AU AL S C Easy Controller by CA 8 The easy remote c
9. ss the MENU button again Menu Mode Press the MENU button up to when the IMG jg showing on the display Then Use DOWN and UP button to select dau Pressing ENTER button and the display will blink Use DOWN and UP button to select the or mode Once the mode has been selected press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds To go back to the functions without any change press the MENU button twice LED Press the MENU button up to when the is shown on the display Pressing ENTER i an button and the display will blink Use DOWN and UP button to select the 20 or arr mode Once the mode has been selected press ENTER button to setup or automatically return to the main functions without any change after 8 seconds Back to the functions without any change press MENU button again 5B 1 JIG Display Inverse It is good for you to install the unit on the floor or under ceiling Press the MENU button up to when the 23r is blinking on the display Use the ENTER button to change to the mode the MENU button ICIS Display normal mode for the fixture putting on the floor Display inversion mode for the fixture fixing under ceiling rit Fixture Hours Press the MENU button up to when the Fife 5 is blinking on the display Pressing ENTER button and the display will show the number of working hours of the unit To go b
10. the PCB might be out of condition 8 Fixture Cleaning The cleaning of internal must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture s optics e Clean with soft cloth using normal glass cleaning fluid e Always dry the parts carefully e Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days 10B Connect the fixture together in a daisy chain by XLR plug cable from the output of the fixture to the input of the next fixture The cable cannot be branched or split to a Y cable Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system The DMX output and input connectors are pass through to maintain the DMX circuit when no power is connected to the fixture At last fixture the DMX cable has to be terminated with a terminator to reduce signal errors Solder a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a 3 pin XLR plug and plug it in the DMX output of the last fixture Each lighting fixture needs to have an address set to receive the data sent by the controller The address number is between 0 511 usually O amp 1 are equal to 1 3 pin XLR connectors are more popular than 5 pins XLR WARNING Introductions