LX-SO-98A smoke alarm user's manual Thank you for
Contents
1. MULTIPLE FLOOR PLAN SINGLE FLOOR PLAN Lae O o o le o O INTCHEN BEDROOM Gaeta BEDROOM BEDROOM BEDROOM O o O O KITCHEN LIVING ROOM BEDROOM 5 SMOKE ALARM FOR MINIMUM PROTECTION SMOKE ALARM FOR ADDITIONAL PROTECTION meal Installation 1 Press the lock button on the underpan and turn the underpan counterclockwise to make it separated from the product s body place the underpan on the selected installation position and use pencil make hole mark along installation hole on the underpan use electric drill with 6 5mm drill bit to drill two installation holes 6 5 depth 35mm on the mark DIAGRAM 3 DIAGRAM 4 strike plastic dilatant into installation holes fix the underpan on installation hole with 3x30 screw with gasket and tighten the screws fix in 9v cascading battery before fixing it push the red thimble into www lexing com cn STAND ALONE SMOKE ALARMS LX SO 98A 6 make the gap on the alarm aim at the trigonal mark on the underpan press out the lock button and turn clockwise when buttoned in completely you will hear sound 7 when you need to unfix it to replace battery you only press the button and at the same time turn counterclockwise Test 1 test once a week at least Press the button continually the alarm will give the interval alarm sound like Bi Bi Bi After 8 seconds the alarm will cha
2. STAND ALONE SMOKE ALARMS LX SO 98A Thank you for selecting our product LX SO 98A LX SO 98A smoke alarm user S manual LX98 is a photoelectric smoke alarm it accords with ISO DIS 12239 standard it has much effect to detect smoke TU Importance please read the manual carefully and save it f The manual includes important information related to its LUNI operation to ensure your safety you should install one alarm in 3 every room at least dont open the alarm easily to avoid bad effect iS S r46 0 Specification Power source DC 9V Static current lt 10uA Alarm volume gt 85db 3m Low voltage alarm 6 5V 0 5V The place fit to install 1 inthe bedroom and corridor you should install one in every bedroom at least 2 onthe top of the stairway because where is the routeway for escape 3 you had better install alarm in every compartment on every floor including attic and basement 4 install one beside the electronic appliance 5 install it in the middle of the ceiling because smoke always spread upwardly 6 if you cant install it in the middle it should also be installed beyond 10cm away from the wall see diagram 1 if you install it on the wall it should be 10 30 5cm away from the ceiling at least see diagram 2 when your room 5 length is beyond 9m you should install more t
3. han one alarm 9 inthe room with oblique roof diagram 2 the alarm should be more than 0 9m away from the top 10 in movable house the alarm must be 10 30 5cm away from the ceiling because the kind of house has no isolation layer oN 100M 4 CEILING MINIMUM Z BEST HERE NEVERHERE X I ANYWGERE IN THIS AREA MINIMUM MAXIMUM 10CM 4 30 5CM 12 ACCEPTABLE HERE 0 9M 3ft 0 9M 3ft Z DIAGRAM 1 HORIZONTAL DISTANCE FROM PEAK SIDE WALL Y DIAGRAM 2 The place not fit to install 1 where there is burning for example the unventilated kitchen carbarn or fireplace etc 2 near the fanner 3 in damp place the alarm should be 3m at least away from jet head in the bathroom or washing dish machine 4 where the ambient temperature is low than 4 or high than 38 for example outdoor unfinished attic www lexing com cn Jem 9 STAND ALONE SMOKE ALARMS LX SO 98A in the disorderly and dirty place you should make sure that the washing clothes room is clean then you can install the alarm in the very ventilated place smoke will be spread completely where jam appear dont jam the detection window where is beyond 305mm away from incadescent lamp or fluorescence lamp the electronic appliance s noise will cause false alarm in air dead angle like the ceiling corner in the diagram1 10 in the smoking meeting room because smoke will cause alarm very easily
4. nge to the rapid sound like Bi Bi Bi which shows the alarm is normal 2 if it doesnt work like above condition when you repeat to test it take down it and dont dismantle it by yourself you should take it back to the franchiser to deal 3 dont test it with fire 4 after its operation is normal when the battery reach the using time limit it will give low alarm sound to tell you replace the battery 5 Little smoke wont cause alarm the indicator lamp probably will quicken to flash but the product wont alarm so it can prevent false alarm Only when continual smoke reach the alarm value about 10 15 seconds later after smoke enter the alarm slowly it will alarm Dont forget to ventilate the kitchen when cooking 6 when it is inducted by cigarette smoke passing by accidentally the smoke alarm will stop alarming after smoke leave Please set your heart at rest if you want to stop the buzzer sound you can blow air into the smoke alarm to make the smoke in alarm out with air current and stop alarming Regular maintenance test it once a week at least clean it once a month at least use the vacuum cleaner to aspirate dust dont clean it with water or cleanser that will destroy the smoke alarm replace battery if the smoke alarm regularly give a sound at several minutes intervals that indicate the battery energy is shortage and should replace it Fix the battery according to the mark on the battery box the battery type can be as foll
5. ow Carbon and zinc type EVERY DAY 216 OR 2122 GOLDPEAK 1604P OR 1604S Alkaline battery EVERY DAY 522 DURACELL MN1604 MX1604 GOLDPEAK 1604A Lithium battery ULTRALIFE U9VL 5 when regularly checking you should save energy as possible as you can because the alarm energy consumption is very much special attention 1 you can not install the smoke alarm when the battery is not fixed in dont install it forcedly otherwise the red thimble will be destroyed 2 choose durable battery as possible as you can that will make battery s using time longer 3 notice whether the indicator lamp flash once 10 30sec normally or not There is two probability that the indicator lamp dont flash One is that the battery s energy is shortage the other is that the battery is not fixed fitly The simple way is to replace the battery or refix the battery PON gt www lexing com cn ec EEA DE EE STAND ALONE SMOKE ALARMS LX SO 98A 6 after installation you must notice whether the key indicator flash once 10 15sec or not and press the key for several seconds to see whether the buzzer can give sound or not if do that shows normal Above is required to do otherwise the smoke alarm you installed probably dont work Limitation 1 it can only tell us that fire will occur so that you can deal with the fire in time and have more time avoiding great loss 2 itis not safe absolutely because it can not ala
6. rm absolutely when smoke appear if there is obstruction to obstruct smoke or smoke is taken off by air current smoke can not reach the smoke alarm 3 it is not fire extinguisher and also can not induct fire you should have the fire fighting devices to help What to do when fire occur 1 dial telephone to the fire control office 2 dont feel panic keep calm Go through the routeway planned in advanced and leave as quickly as possible dont waste much time to take things 3 feel whether the door is hot or not If hot dont open the door if not you also should prevent the flame in and you can choose other routeway to flee 4 with wet towel cover your mouth and nose dont inbreathe smoke 5 after fleeing out gather in the indicated place and ensure person is not injured or dead ISO9S001 NINGBO LEXING INDUCTOR ELECTRONIC CO LTD Add No 35 Zhuquan Road Science amp Technology Area E mail lexing lexing com cn Ninghai Ningbo Zhejiang China E mail lexing globalmarket com S O 1 400 1 Tel 86 574 65335088 www lexing com cn Fax 86 574 65335000 65335333 www lexing com www lexing com cn
Download Pdf Manuals
Related Search
Related Contents
AMBAR - guica, s.a. Marsh Electra Taper Owner`s Manual Manuel d`utilisation du Pioneer AVIC-F90BT User's Manual Manual Icom IC-2100H Esp - Radio Club Los Libertadores Reliable MSK-8400BL-18 User's Manual Sony HDC-F950 User's Manual 取扱説明書の表示 Computer Gear 27-0007 power cable tendances - Lefranc & Bourgeois Chess Challenger scan Copyright © All rights reserved.