Home
USER'S MANUAL - Communications Specialties, Inc.
Contents
1. NOTE Use this manual in conjunction with the spiral bound manual also provided with this kit READ THIS MANUAL FIRST PURE DIGITAL N FIBERLINK ss fc eS 7S Fiber Optic Termination Kit P N 6202 USER S MANUAL DEd CSI semei WORLD HEADQUARTERS 55 Cabot Court Hauppauge N Y 11788 USA Tel 631 273 0404 Fax 631 273 1638 www commspecial com Email info commspecial com Communications Specialties Pte Ltd 100 Beach Road 22 09 Shaw Tower Singapore 189702 Tel 65 6391 8790 Fax 65 6396 0138 Email csiasia commspecial com 2002 Communications Specialties Inc P N 122003 Rev B INTRODUCTION This fiber optic installation kit enables the user to terminate both single mode and multimode fiber optic cable with either ST or FC type connectors The kit is assembled in two parts the Corning UniCam termination kit which is packed in a blue bag and the CSI supplementary materials kit which is packed in a clear bag This manual is intended to be used in conjunc tion with the spiral bound manual packed inside the blue bag Please note that this termination kit is intended to work only with Corning UniCam brand connectors These connectors are sold by Communications Specialties as part numbers 6210 ST type connector for use with 62 5 micron multimode fiber 6211 FC type connector for use with 62 5 micron multimode fiber 6221 ST type connector for use with 8 10 micron single mode fiber
2. 6220 FC type connector for use with 8 10 micron single mode fiber This Kit Contains 1 Corning UniCam termination kit refer to Page 4 Section 3 in the spiral bound manual for a complete listing of contents 1 CSI supplementary materials kit including ST ST adapter ST FC adapter ST ST multimode orange jumper cable 1 meter ST ST single mode yellow jumper cable 1 meter Visible Laser Light Source VLLS with power supply bi ee ee a Connectors are not included and must be purchased separately Theory of Operation This kit is designed to provide a reliable quick and easy method to termi nate fiber optic cable using Corning UniCam ST or FC type connectors These unique connectors have a pre polished tip with a small piece of fiber inside This eliminates the need for polishing the end of the connector or for using epoxy to secure the fiber cable in the connector When a prepared fiber cable is inserted into the connector it mates with the piece of fiber that is already inside A small amount of optical coupling gel is also inside the con nector to facilitate the transmission of light from one piece of fiber to the other The Visible Laser Light Source VLLS included in the supplementary mate rials kit is used in the termination process to shine a red beam of light into the tip of the connector When no fiber is inserted into the connector the red light visibly disperses around the body of the connector As f
3. Connectors 1 2 3 4 5 6 7 With the VLLS positioned in front of you with the crimp handle on the left as shown in the diagram on Page 14 insert the ST ST adapter between the slider and the crimp platform Position the adapter so that the word TOP is facing upwards Place one end of the ST ST jumper cable through the opening in the crimp handle and then connect it to the left side of the ST ST adapter It is very important that the jumper cable go through the crimp handle Connect the other end of the jumper cable to the VLLS Make sure the VLLS is turned OFF Go to Page 11 of the spiral bound manual Read all of Section 5 completely before proceeding Please note the procedure described does NOT assume that the ST ST adapter and the VLLS are being used The protective end cap on the connector must be removed and mated with the right side of the ST ST adapter in the slide top before being placed into the crimp platform Make sure the cam on the connector is properly positioned as indicated in Figure 5 7 on Page 15 The cam will face you when properly installed into the crimp platform Strip and prepare the fiber as indicated in Section 5 Once the fiber is prepared turn ON the VLLS The VLLS should be on before you place the fiber end into the connector When the fiber is properly mated into the connector the red light will be 3 8 extinguished around the outside of the connector There may still be
4. some light illuminating the rear of the connector Try to minimize this light as much as possible but it is normal to have a small amount remaining Continue the termination procedure as indicated on Page 27 Section 5 7 10 Steps for Terminating Fiber Using FC Connectors 1 2 3 4 5 6 7 8 With the VLLS positioned in front of you with the crimp handle on the left as shown in the diagram on Page 14 insert the ST FC adapter between the slider and the crimp platform Position the adapter so that the ST con nector is on the left the FC connector is on the right Place one end of the ST ST jumper cable through the opening in the crimp handle and then connect it to the left side of the ST ST adapter It is very important that the jumper cable go through the crimp handle Connect the other end of the jumper cable to the VLLS Make sure the VLLS is turned OFF Go to Page 11 of the spiral bound manual Read all of Section 5 completely before proceeding Please note the procedure described does NOT assume that the ST FC adapter and the VLLS are being used The protective end cap on the connector must be removed and mated with the right side of the ST FC adapter in the slide top before being placed into the crimp platform Make sure the cam on the connector is properly positioned as indicated in Figure 5 7 on Page 15 The cam will face you when properly installed into the crimp platform Strip and prepare the fiber as indic
5. ated in Section 5 Once the fiber is prepared turn ON the VLLS The VLLS should be on before you place the fiber end into the connector When the fiber is properly mated into the connector the red light will be extinguished around the outside of the connector There may still be some light illuminating the rear of the connector Try to minimize this light as much as possible but it is normal to have a small amount remaining Continue the termination procedure as indicated on Page 27 Section 5 7 10 4
6. iber is inserted into the con nector during the termination process the light becomes piped into the fiber cable and is no longer dispersed The extinguishing of all visible light indicates that the beam is being successfully channeled directly into the fiber cable and that the connector has therefore been properly aligned for termination TERMINATION INSTRUCTIONS Getting Started 1 First refer to the following pages in the spiral bound manual entitled Assembly Instructions for Corning Cable Systems UniCam Connectors SC ST compatible FC MT RJ Compatible and LC Connectors a Page 4 Review the list of contents that should be included in the blue bag and familiarize yourself with these items b Page 5 Read the description for Enhanced UniCam Tool Set Up and make sure that the WIDE slide top is installed as indicated This is used for both ST and FC type connectors when the VLLS is used c Page 10 Read the Laser Handling Precaution warning Section 4 5 2 2 3 d Page 14 Look at the picture in Figure 5 5 and position the UniCam tool as shown in the diagram such that the crimp handle is on your left Prepare the VLLS for use by installing a 9 volt battery in the unit or using the external AC adapter If you are terminating a single mode fiber use the yellow ST ST jumper cable If you are terminating a multimode fiber use the orange jumper cable Steps for Terminating Fiber Using ST
Download Pdf Manuals
Related Search
Related Contents
Spirotrac IV 4.32 - Vitalograph GmbH Replacement Cartridge Midwest Quiet Air or Plancha seca AXW-1000 PAR 36-PUNKTSTRAHLERGEHÄUSE Samsung GT-I8150 Uporabniški priročnik Manual del usuario de la Serie VS - Electro 1507/1503 Insulation Testers 476号 - 自由法曹団 東京支部 Samsung GT-P3100 Керівництво користувача(Jellybean) Copyright © All rights reserved.