Home
LTX2 User Manual
Contents
1. LRSet SampleMode LRSetUserDir RStop LRTruncate RWrite XLRWriteData L L L LRSetWriteProtect L L Bd The LTX2 system does not currently support event capture or bank switching See the StreamStor SDK user manual for more information SDK and Network Operation Most API commands will work in an identical fashion in either Network or PCI Star Fabric modes The main exception is the open command XLROpen is used when the L TX2 is connected to the host over Star Fabric XLRNetOpen is required when the LTX2 is connected to the host PC over Ethernet TCP IP More details on each command can be found in the function reference section of the StreamStor SDK Users Manual 22 LTX2 USER MANUAL Daughter Boards The LTX2 StreamStor controller includes the capability to add a daughter board mezzanine with its own connectors and electronics to provide an alternate method of transferring data into and out of StreamStor These additional paths offer several advantages including freedom from interaction with other devices on an arbitrated bus such as PCI the reduction or elimination of bus FIFOs that may otherwise be required to interface with an arbitrated bus full isolation of the data path from operating system and computer hardware facilitates predictable and repeatable behavior better or additional control over timing and other
2. Big River LTX2 Real time Disk System Installation and User Manual Copyright and Trademarks The information in this document is subject to change without notice This document contains proprietary information that is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated to another language without the prior written consent of Conduant Corporation Printed in the United States 2008 Conduant Corporation All rights reserved StreamStor is a trademark of Conduant Corporation All other trademarks are the property of their respective owners Version 8 2 Publication date April 10 2008 LTX2 USER MANUAL TABLE OF CONTENTS ABOUT THIS MANUAL cscssssssssssssssrsessesssserscssssessessssessessssensesersesscssssessesesssscsensessesensensesensessesenenseeses 7 ABOUT THE LTX2 REAL TIME STORAGE 8 64 bit x 100 DDR 1 6 SSDB2 LVDS Mezzanine interface 800MB s DMA Engine Local Bus 32 x 66Mhz PCI Bus 16x SATA 10 100 Ethernet Command Control star Fabric PCI Bridge Interface 4x Cat5 M 9 SPECIFICATICNS eetcseseceatece cesi ce ei ee rase subeosebuanseedesaceusctascecsen abet Fee UH a Ta 10 COMPO
3. 249 92 8 Exit without save 9 Save and exit Your choice 1 Baudrate lt 19200 gt I F Mode Flow Port No 188001 718088 iConnectMode CB Remote IP Address lt 000 gt 000 gt 000 gt Remote Port lt DisConnMode gt F lus hMode ag DisConnTime lt 00 00 sendChar 1 gt SendChar 2 gt Change Setup O Server configuration Channel 1 configuration E mail settings Expert settings Security Factory defaults Exit without save Save and exit Your choice Installing the Software Your system was shipped with the Software Development Kit on CD ROM Install the software prior to installing the hardware if possible On Windows systems when ready run the setup exe program on the CD ROM to start the installation process Plug and play operating systems such as Windows will detect the installation of the StreamStor board if the LTX2 is connected via Star Fabric and attempt to configure the system using the hardware plug and play wizard program The required installation information file for plug and play installation is included on the CD ROM Make sure the plug and play wizard includes the CD ROM drive in its search so that the StreamStor drivers will be properly installed You should not cancel the plug and play wizard since this can create hardware conflicts in the system when using the StreamStor controller Note that the setup exe program m
4. RErase Ba Ba D By eAppend eFind ata seAddr seRange Info RGet LRGel LRGel LRGel RGet De De Di Dr Dr Er E En p viceInfo viceStatus rectory iveInfo iveTemp rorMessage bel stError ngth RGet Le ngthPages RGet Le RGe RGe RGe tMo tOp tPa EPI ngthLowHigh de tion rtitionInfo iRGetP 1 ayBufferStatus ayLength RGe LRGe RGe tSa tsy tUs KOO OOKO acm ade die ie dU e nal mple stemAddr erDir 21 LTX2 USER MANUAL RGetUserDirLength RGetVersion LRGetWindowAddr LRNetOpen Ethernet only LROpen RPartitionCreate LRPartitionSelect LRP layback LRP laybackLoop LRPlayTrigger RRead XLRReadData iRReadiImmed RReadSmartThresholds ReadSmartValues ReadStatus RRecord HR R R LR R R RRecoverData R Reset LRSelectChannel LRSelfTest RSet DBMode RSet Label LRSetMode LRSetOption LRSetPlaybackLength LRSetPortClock not available for Serial FPDP daughter oards LRSetReadLimit e be sede
5. SEVERABILITY This Agreement constitutes the complete and exclusive agreement between you and Conduant Corporation with respect to the subject matter hereof and supersedes all prior written or oral agreements understandings or communications If any provision of this Agreement is deemed invalid under any applicable law it shall be deemed modified or omitted to the extent necessary to comply with such law and the remainder of this Agreement shall remain in full force and effect GOVERNING LAW This Agreement is governed by the laws of the State of Colorado without giving effect to the choice of law provisions therein By accepting this Agreement you hereby consent to the exclusive jurisdiction of the state and federal courts sitting in the State of Colorado LTX2 USER MANUAL About This Manual This manual is intended to serve the following purposes to provide an overview of the StreamStor LTX2 Real Time Storage Controller act as a guide for hardware installation to act as a reference for the operator to provide guidance on software capabilities and choices It is suggested that you periodically check the Conduant web site for the most recent software updates application notes and technical bulletins If you are unable to locate the information you need please feel free to contact us by e mail or phone LTX2 USER MANUAL About the LTX2 Real Time Storage System Thank you for purchasing the Conduant LTX2 Real Ti
6. develop custom daughter boards for unique or proprietary interface requirements LTX2 USER MANUAL The StreamStor SDK includes the device drivers and API Application Programming Interface to provide a smooth integration of the LTX2 with the data acquisition device and or analysis software Many examples are provided with the SDK and mote are available upon request The LTX2 system is a flexible and powerful platform for high performance recording applications The system also has the capability to provide a web based interface to allow command control from nearly any networked computer Many custom and unique capabilities are available that are beyond the scope of this documentation so please contact Conduant with your questions and special requirements 64 bit x 100 DDR 1 6 SSDB2 LVDS Mezzanine interface 800MB s DMA Engine Local Bus 32 x 66Mhz PCI Bus 16x SATA 10 100 Ethernet C d Control Commeand Contro Star Fabric Bridge Interface 4x Cat5 Figure 1 LTX2 Block Diagram LTX2 USER MANUAL Specifications Note that environ mental specifications will vary with disk drive selection Weight 12 lbs Drive weight Typically 0 25 lbs per drive Size H 1 7 43mm x W 15 5 394 x D 15 25 387mm Power 10A 212 VDC 10 Environmental Operating Temperature 5C to 50C operating Shock half sine wave 300G 2 ms 160G 1
7. ms Non Operating Temperature 40C to 65C Shock half sine wave 1000G 1 ms Altitude 10 000 feet with magnetic disk Capacity Varies with disk model up to 16 internal 2 5 SATA disk drives magnetic or solid state Interfaces Stat Fabric 10 100 Ethernet Various data interfaces including FPDP FPDP2 Serial FPDP optical LVDS Camera Link Components The LTX2 real time storage system generally consists of the following components LTX2 System Chassis Star Fabric interface board optional e External AC DC Power supply optional e Star Fabric CAT5 Interface cables Qty 4 optional StreamStor Software Development Kit User Manual s 10 LTX2 USER MANUAL CAUTION Phase read the entire installation section before starting to install the LTX2 hardware This manual assumes that the user is Rnowledgeable and comfortable with basic computer work including installation and safety considerations If you are unsure as to how to proceed please contact Conduant support 11 LTX2 USER MANUAL Unpacking Handling Carefully inspect all shipping packages for any sign of damage In particular look for wrinkled or bent corners holes or other signs of bad handling or abuse If you notice any damage to the packaging immediately open the boxes and inspect the contents for damage Pay close attention to the components near the area where the packing material was damaged Report an
8. the following steps prior to calling us This way you can provide us with the most meaningful information possible that will help us solve the problem ls the problem one that obviously requires replacement parts due to physical damage to the system If yes then please gather the information described below and report the problem to tech support by phone or through the Conduant web site Have you confirmed that no cabling has been inadvertently disconnected or damaged while working around the equipment Do all the systems have good power connections and voltages Does the confidence test ssofg exe run Has the software installation been corrupted Try re installing software Have you checked the Conduant web site for technical bulletins Have you recently installed a new compiler or a new Windows Service Pack If the above steps did not resolve the problem then please initiate a trouble ticket on the support section of the Conduant website at www conduant com Please provide as much information about your system and the problem as possible We will do all that we can to resolve the problem as quickly as possible 24 LTX2 USER MANUAL Contacting Technical Support E mail support conduant com Web www conduant com Mail Conduant Corporation Technical Support 1501 South Sunset Street Suite C Longmont CO 80501 25
9. to the Software including but not limited to all copyrights trademarks trade secrets know how and other proprietary information included or embodied in the Software The Software is protected by national copyright laws and international copyright treaties TERM This Agreement is effective from the date of receipt of the StreamStor Product and the Software This Agreement will terminate automatically at any time without prior notice to you if you fail to comply with any of the provisions hereunder Upon termination of this Agreement for any reason you must return the StreamStor Product and Software in your possession or control to Conduant Corporation LIMITED WARRANTY This Limited Warranty is void if failure of the StreamStor Product or the Software is due to accident abuse or misuse Hardware Conduant s terms of warranty on all manufactured products is one year from the date of shipment from our offices After the warranty period product support and repairs are available on a fee paid basis Warranty on all third party materials sold through Conduant such as chassis disk drives PCs bus extenders and drive carriers is passed through with the original manufacturer s warranty Conduant will provide no charge service for 90 days to replace or handle repair returns on third party materials Any charges imposed by the original manufacturer will be passed through to the customer After 90 days Conduant will handle returns on third party ma
10. MS AND CONDITIONS OF THIS AGREEMENT BEFORE USING THE PRODUCT By installing or otherwise using the StreamStor Product you agree to be bound by the terms of this Agreement If you do not agree to the terms of this Agreement do not install or use the StreamStor Product and return it to Conduant Corporation GRANT OF LICENSE In consideration for your purchase of the StreamStor Product Conduant Corporation hereby grants you a limited non exclusive revocable license to use the software and firmware which controls StreamStor Product hereinafter the Software solely as part of and in connection with your use of the StreamStor Product If you are authorized to resell the StreamStor Product Conduant Corporation hereby grants you a limited non exclusive license to transfer the Software only in conjunction with a sale or transfer by you of the StreamStor Product controlled by the Software provided you retain no copies of the Software and the recipient agrees to be bound by the terms of this Agreement and you comply with the RESALE provision herein NO REVERSE ENGINEERING You may not cause or permit and must take all appropriate and reasonable steps necessary to prevent the reverse engineering decompilation reverse assembly modification reconfiguration or creation of derivative works of the Software in whole or in part OWNERSHIP The Software is a proprietary product of Conduant Corporation which retains all title rights and interest in and
11. NENTS S 10 UNPACKING HANDLING eher seko CaN aero SE a ra ek ao n 12 TDIR A DI 12 STAR FABRIC BOARD OPTIONAL c cccceceesssscecececsesseaececececseneaeeecececeeseneeeseeccseseneaeseeeeeceesesaeeeeececeensaaeea 12 PLANNING YOUR INSTALLATION ccsssscsssssccssssscccsssccscesssccsessscessssssccesscsccssssceccessecsecesseccscssseesees 13 BASIC OPERATION 14 Ny ag guo 14 CONNECTIONS M 15 15 NETWORK CONNECTIVITY tetto eot rho reo toco eorr ehe e rea ehe coe E DER AR ee 15 CONFIGURATION RR 16 LTX2 USER MANUAL INSTALLING THE 19 SOFTWARE FUNCTIONALITY sssssssssssssssssssscssereresssssssssssessesssesssessssssnsnsnssssssssesesesesesesssssessesesens 21 SDK AND NETWORK OPERATION sortin i a E E E E T E E a 22 DAUGHTER BOARDS sos esses esseere osooso 23 TECHNICAL SUPPORT esissaicccsssacssssssesuccassisessiasescescevadecsspsassacescscoasassessceassoceseaasoseasadcssesbesseadgeacsadsssscsesace 24 CONTACTING TECHNICAL SUPPORT aereoa n eerie hee E spe ane eei e fne eite edge 25 LTX2 USER MANUAL License Agreement and Limited Warranty IMPORTANT CAREFULLY READ THE TER
12. NT PERMITTED BY APPLICABLE LAW IN NO EVENT SHALL CONDUANT CORPORATION BE LIABLE FOR ANY SPECIAL INCIDENTAL INDIRECT OR CONSEQUENTIAL DAMAGES WHATSOEVER INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION LOSS OF BUSINESS INFORMATION OR ANY OTHER PECUNIARY LOSS ARISING OUT OF THE USE OF OR INABILITY TO USE THE STREAMSTOR PRODUCT AND THE SOFTWARE IN ANY CASE CONDUANT CORPORATION S ENTIRE LIABILITY UNDER ANY PROVISION OF THIS AGREEMENT SHALL BE LIMITED TO THE AMOUNT ACTUALLY PAID BY YOU FOR THE STREAMSTOR PRODUCT AND THE SOFTWARE BECAUSE SOME STATES AND JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY THE ABOVE LIMITATION MAY NOT APPLY TO YOU RESALE If you are authorized to resell the StreamStor Product you must distribute the StreamStor Product only in conjunction with and as part of your product that is designed developed and tested to operate with and add significant functionality to the StreamStor Product you may not permit further distribution or transfer of the StreamStor Product by your end user customer you must agree to indemnify hold harmless and defend Conduant Corporation from and against any claims or lawsuits including attorneys fees that arise or result from the use or distribution of your product and you may not use Conduant Corporation s name logos or trademarks to market your product without the prior written consent of Conduant Corporation ENTIRE AGREEMENT
13. board 12 LTX2 USER MANUAL Planning Your Installation 2 NOTE The LTX2 is designed to allow rack mounting or table top operation There are optional mounting brackets available to adapt the unit to a standard EIA equipment rack Please contact your Conduant sales representative for more information All electrical connections are designed to come off the front or rear panels The rear panel utilizes a Molex 39 01 2061 6 pin power connector for 12V and ground connections The mating connector is Molex 39 01 2060 customer drawing is available with detailed dimensions mounting holes and wiring schematic Please contact your Conduant sales representative for more information There is an optional AC power supply available from Conduant part 020030204 The front panel connections include 4 RJ45 connectors for the Star Fabric interface and an additional RJ45 connector for the Ethernet interface The data interface connector will vary depending on the installed interface mezzanine board The LTX2 is not designed to have other systems stacked on top Doing so may cause damage to the internal components Please suppott these components separately 13 LTX2 USER MANUAL Basic Operation When the LTX2 is connected to a 12V power supply an optional AC supply is available the yellow standby LED will be illuminated Pressing and holding the power switch for 3 seconds will toggle the power on or off During device i
14. data to system memory are compatible with the LTX2 Only minor software modifications are generally required to redirect data to the LTX2 PCI Star Fabric interface This capability is often in the software provided by the manufacturers of such data acquisition devices The StreamStor technology used in the LTX2 was specifically designed to record sequential data without interruption at very high data rates This is in contrast to traditional storage systems that are designed for data processing purposes and cannot sustain these high data rates Unlike typical computer disk storage solutions that are designed for optimum performance during random data reads and writes StreamStor has been designed for optimum performance in sequential read and write operations The StreamStor system has also been designed to operate without host computer intervention This eliminates any bottlenecks or interruptions in the data stream due to heavy computer loads or delays The LTX2 system includes the capability of adding daughter mezzanine boards to provide different types of external interfaces such as the FPDP FPDPII interface Available interface include FPDP FPDPII Camera Link LVDS 32 ot 16 bit and Serial FPDP optical These daughter boards move data to from the LTX2 system at very high data rates with very little overhead This provides a seamless method of interfacing to nearly any external data interface for high performance recording Conduant can also
15. k 255 255 255 0 Gateway 10 1 249 254 The serial port settings must be e Baud rate 19200 e Data bits 8 Parity N none Stop bits 2 There are 2 alternatives for configuring the LTX2 Ethernet port For Windows Operating systems it is suggested that you use the Lantronix installation configuration tool For other operating systems you must use telnet as described below to configure the network settings The installation CD includes a sub directory named L TX2 which contains the Lantronix Windows configuration tool and a user manual for this tool To install this tools simply execute the program DI_Web exe This will install the tool onto your system and allow configuration of the LTX2 network interface See the Lantronix manual Xport_userguide pdf for further instructions on using this tool to configure the LTX2 For either installation method the LTX2 must be connected to the network with a standard Cat5 cable A direct connection to a host with a loopback cable is also possible for configuration purposes Note that the LTX2 must be on the same network segment no router to perform this configuration Perform the following steps to modify the LTX2 s default IP address and configuration using a telnet connection 1 Connect the LTX2 s Ethernet port via CAT5e to a standard 10 100 Ethernet hub switch or to a host PC via a loopback cable Note that this configuration must be performed with the two devices on the sa
16. me Storage System Your StreamStor based system is a disk based real time recording system for external data sources which can operate standalone or connected to a host computer The system consists of a 1U chassis housing a StreamStor Amazon controller and high performance disk drives Included with your system are the device drivers softwate development tools and additional utility software required to adapt the system to your specific application The LTX2 system will usually include an optional mezzanine board to provide external data interfaces for data recording and playback The PCI bus is a high performance I O bus designed for attaching peripheral devices to computer systems It is found in computing systems from many different manufacturers and is supported by most major operating systems The LTXZ system includes a Star Fabric interface that provides a cabled bridge to the computer PCI bus By utilizing the PCI bus instead of a proprietary bus interface the LTX2 provides an open platform recording system accessible from softwate applications running Windows or Linux operating system on the host computer The LTX2 provides a large capacity and cost effective alternative to system memoty or other storage solutions for these applications The LTX2 System is able to receive data over the PCI bus directly from the data acquisition device at very high average sustained data rates Virtually all of the available PCI cards that can record
17. me network segment 2 Open a command prompt Start gt Run cmd and type telnet 10 1 249 101 0999 9999 is the special LTX2 port number for telnet configuration This 15 NOT the port described above 16 LTX2 USER MANUAL 3 Press Enter when prompted and the main menu will appear 4 Press 0 to enter Server Configuration and follow the prompts to enter a new static IP address If DHCP configuration is desired enter Os for the IP address and follow the prompts 5 When finished press 9 to save and exit The following screen shot shows the IP address configuration being changed from the default static IP assignment to a DHCP configuration elnet 10 1 249 92 Server configuration Channel 1 configuration E mail settings Expert settings Security Factory defaults Exit without save Save and exit Your choice IP Address lt 010 gt lt 001 0 lt 249 gt 092 A Set Gateway IP Address ND N Netmask Number of Bits for Host Part default gt lt 0 A Change telnet config password ND N Change DHCP device name not set N N Change Setup O Server configuration Channel 1 configuration E mail settings Expert settings Security Factory defaults Exit without save Save and exit Your choice The following screen shot shows the static IP address being changed from the default to 10 1 249 90 17 LTX2 USER MANUAL cx Telnet 10 1 249 92 m Change Setup O Server configura
18. nitialization performed via an XLROpen command when connected via Star Fabric and an XLRNetOpen command when using the remote interface the power LED may briefly extinguish until the disk drives are powered on Upon completion of device initialization the power and ready LEDs should be Drive Activity LED s Mezzanine Interface Status LED s Ethernet 10 100 Star Fabric Connectors illuminated although it may take an additional 30 seconds before the system will respond to commands The LTX2 can be connected to a host system with Ethernet or a Star Fabric PCI bridge connection When using the Star Fabric interface the LTX2 will operate identically to having a StreamStor Amazon board installed in the system Either interface can be used to provide command conttrol to the system but data access can only be performed using the Star Fabric interface Star Fabric The Star Fabric interface on the LTX2 is used to create a PCI expansion connection back to a host PC It creates a bridged PCI segment that is recognized by neatly all operating systems without any additional software or special drivers Once connected successfully the Big River LTX2 appears as an ordinary StreamStor device on the host PC as if it was a card plugged directly into the computer PCI bus A Star Fabric interface card must be installed in the host PC and is usually a 64 bit add in PCI catd Star Fabric can operate in either 32 33 32 bits 33 MHz
19. or 64 66 64 bits 66 MHz PCI modes The main difference is that in 32 33 mode maximum PCI bus speeds ate around 100 MB s whereas 64 66 mode can achieve 200 MB s For 32 33 operation the Star Fabric host board can be in neatly any available PCI slot and at least Link 1 2 cables TX and RX must be connected For maximum performance the interface card should be in a 64 66 PCI or faster slot and both Link 1 and Link 2 4 cables are connected 14 LTX2 USER MANUAL The TX and RX ports that are labeled as Link 1 on the LTX2 are equivalent to LO or Link 0 on the Star Fabric host card And the TX and RX ports that are labeled as Link 2 on the LTX2 are equivalent to L1 or Link 1 on the Star Fabric host catd Connections 8 CAUTION NOTE Operation Over flexing the circuit board will damage the host adapter Ensure that both the host PC and the LTX2 are powered oft Locate the dip switches or configuration jumpers on the Star Fabric host card Ensure that the card is configured as a root device and that it is configured to operate in bridge mode Carefully insert the host card into the PC Following the diagram on the upper portion of the host bracket connect the first RX port of the host board into the TX port of the LTXZ s Link 1 connectors Next connect the first TX port ie 0 of the host board into the RX port of the LTX2 s Link 1 connectors Complete the same seq
20. parameters higher bus utilization efficiency due to a non arbitrated nature access to interface signals without risk of crashing host computer higher data rates than the most common PCI buses support and potential for dual port operation simultaneous transfers on both PCI bus and external ports while recording or playing back If an optional daughter board is ordered with your LTX2 board it will come completely installed and ready to use The XLRSet DBMode function in the API is used to program the behavior of the daughter boards and the modes and options are unique to the specific type of daughter board installed Please refer to the programming manual provided for your specific daughter board These documents use the naming convention 4 where xxxxx is the interface type implemented by the daughter board e g FPDPZ pdf and are also available on the CD delivered with your system 23 LTX2 USER MANUAL Technical Support Conduant wants to be sure that your LTX2 StreamStor system works correctly and stays working correctly In the event however that you are unable to get yout new system to work properly or if a working system ceases to function we will do all that we can to get your system back online Solving the problem is largely a matter of data collection and steps that must be taken one at a time In order for us to better serve you we ask that you take the time to perform
21. terial on a time and materials basis LTX2 USER MANUAL Software The warranty on all software products is 90 days from the date of shipment from Conduant s offices After 90 days Conduant will provide product support and upgrades on a fee paid basis Warranties on all third party software are passed through with the original manufacturer s warranty Conduant will provide no charge service for 90 days to replace or handle repair returns on third party software Any charges imposed by the manufacturer will be passed through to the customer DISCLAIMER OF WARRANTIES TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW CONDUANT CORPORATION DISCLAIMS ALL OTHER WARRANTIES AND CONDITIONS EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE TITLE AND NONINFRINGEMENT WITH REGARD TO THE STREAMSTOR PRODUCT AND THE SOFTWARE SOLE REMEDIES If the StreamStor Product or the Software do not meet Conduant Corporation s Limited Warranty and you return the StreamStor Product and the Software to Conduant Corporation Conduant Corporation s entire liability and your exclusive remedy shall be at Conduant Corporation s option either a return of the price paid if any or b repair or replacement of the StreamStor Product or the Software Any replacement Product or Software will be warranted for the remainder of the original warranty period LIMITATION OF LIABILITIES TO THE MAXIMUM EXTE
22. tion Channel 1 configuration E mail settings Expert settings Security Factory defaults Exit without save Save and exit Your choice IP Address 8185 10 408015 1 4249 249 0925 96 Set Gateway IP Address ND Netmask Number of Bits for Host Part default gt Change telnet config password ND N Change Setup Server configuration Channel 1 configuration E mail settings Expert settings Security Factory defaults Exit without save Save and exit Your choice Perform the following steps to change the default IP port number 1 Connect the LTX2 s Ethernet port via CAT5e to a standard 10 100 Ethernet hub switch or to a host PC via a loopback cable 2 Open command prompt Start gt Run and type telnet x x x x 9999 where x x x x is the default IP address listed above 9999 is the special LTX2 port number for telnet configuration This is NOT the port described above 3 Press Enter when prompted and the main menu will appear 4 Press 1 to enter Channel 1 configuration At each prompt press enter to leave it blank except for the Port No prompt Enter a new port number at this prompt and press enter The following screen shot shows the port number being changed from the default 10001 to 10000 5 When finished press 9 to save and exit The following screen shot shows the TCP IP port number being changed from the default to 10000 18 LTX2 USER MANUAL cs Telnet 10 1
23. uence for the second set of ports if 64 66 PCI operation is desired Power on the LTX2 and make sure that both the standby and power LEDs are illuminated green Power on host PC Green LEDs should be illuminated on the LTX2 s Star Fabric connectors and on the Star Fabric host board itself Solidly illuminated LEDs indicate the connection is ok Blinking LEDs indicate either the cable connections are incorrect or that the LTX2 was not powered before the host PC The LTX2 must be powered on BEFORE the host PC Otherwise the host PC will NOT recognize the LTX2 StreamStor Upon completion of the host PC s boot install the SDK if it is not already installed Windows users may be required to install a driver via the driver wizard If so point the driver wizard to the SDK CD and follow the prompts Upon completion of the installation routine run the StreamStor Config Test utility Network Connectivity The Big River LTX2 is equipped with a 10 100 Ethernet port which allows command and control of the LTX2 over a standard TCP IP network Note that this port is not intended or designed for data movement to from the unit The 15 LTX2 USER MANUAL LTX2 can be assigned a static IP address can be configured via DHCP This interface is not required if a Star Fabric interface is available Configuration The LTX2 is configured at the factory with a static IP configuration of P address 10 1 249 101 e 10001 Netmas
24. ust still be executed to install the StreamStor SDK onto your system The software installation procedure will install the device drivers library files example programs and all other components of the SDK onto your system The StreamStor SDK does not include software interfaces or drivers used for the control of data acquisition cards made by other manufacturers However it does include some sample programs to help in your software development efforts Other drivers and examples may be available depending on your choice of data acquisition hardware Contact Conduant support for more information 19 LTX2 USER MANUAL Always review the readme html file included with the SDK for the latest information not included in this manual Also check the Conduant web site periodically for additional information 20 LTX2 USER MANUAL Software Functionality The LTX2 StreamStor controller supports recording and playback or read from the PCI bus or a daughter b oard interface The following API commands ate supported by the LTX2 controller Note Only those functions marked with an asterisk are available when using the Ethernet interface RApiVe RAppen 1 RBindO Li Li E 4 RC RC ear ear ear RCardReset rsion a npu utp tChannel ut Channel Channels Option WriteProtect iRClose RDelet HR RDevic REdit R R REditD
25. y damage to the carrier and Conduant immediately Disk Drives Hard disk drives such as those that have been included within your system are susceptible to damage from excess shock and careless handling Please observe the following handling precautions Allow the disk drives to reach room temperature BEFORE applying power to the system This may take several hours depending on shipping conditions Disk drive damage can occur if the system is powered while the drives are at temperature extremes Do not drop jar or bump the system Even setting the chassis on a hard surface too roughly can damage the recording surfaces heads or other mechanical components inside the disk drives Star Fabric Board optional The LTX2 system is shipped with an optional Star Fabric board in a specially designed box or bag to prevent electrostatic damage to the board There should be separate installation instructions included with that board To avoid damage in handling the board take the following precautions Ground yourself with a grounding strap or grasp a conductive grounded object to dissipate any static charge while handling the board Always store the board in its antistatic package when not installed in a computer system Inspect the board carefully before installing in the computer Do not install a damaged board into your computer Never touch any exposed connector pins or component leads Avoid bending or twisting the
Download Pdf Manuals
Related Search
Related Contents
Wireless Rain Gauge with Indoor / Outdoor Thermometer Model Cisco AIR-CT5508-500-2PK How to Make Custom Chopper Saddles Linn CD Playback System User's Manual Tektronix Cordless Sander 2205 User's Manual Personal Care, Hygiene, and Grooming warning - P.C. Richard & Son CONTROLE DE L`EAU POUR HEMODIALYSE Copyright © All rights reserved.
Failed to retrieve file