AD2031 SWITCHER FOLLOWER Installation and Operating

image

Contents

1. ALARMS RELAY CODE CAMERAS E 1 5 7 9 11 13 15 17 19 21 23 25 27 29 31 MONITORS 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 a KEYBOARDS e e e OOOO OOOO OO E 9 9 9 ur Eat 2 3 4 5 RS232 PORTS 2150 BWS Berges MONITOR MONITOR MONITOR MONITOR 8 7 6 5 4 3 2 1 1 2 LT A 0 O A Oy A 0 0 Oj A 3 4 O B o B O B O B O B do B 9 o on 39 1650 1650A from 1600 1650A or 2150 Systems 0 0 0 9 9 9 7 10 8 13 11 ik na 48 709 E GROUP ebene NO a ABFA HF e s 18 2119 293 284 2027 30 28 ot 32 GROUP 2 BE ABCDEF GiIN G1 OUT G2 IN G2 OUT 99 9 9 9 0 9 0 0 0 0 0 99 9 9 9 0 9 0 0 0 0 0 DON BWS 2031 DATALINE OUT to additional 2031 s or 75 ohm terminator DECLARATION OF CONFORMITY According to ISO IEC Guide 22 and EN45014 Manufacturer s Name Sensormatic Electronics Corporation Manufacturer s Address 1
2. 0000050090000 ABLABLABJABL J ABIABIABI OFF i le 0000090 9999 NIA ANS BWS GROUP2 ABCDEF ON OFF ABCDEF ABCDEF ABLABL ABLABLABlABL aBlaBlaBlaBl aBlaBlaBlaBl PWR O ON orr 20 21 22 23 24 25 2 27 28 299 30 1 32 DATA O ABCDEF ooo 99 999 999 99 NADA UA NOUIS UIN UI SIN ABLABLABLABL 999 999 9996 999 I NAD 120V 60Hz Q G1 IN G1 OUT G2IN Lun lee NAD ABLABLABLABL AN Figure 2 Location of DIP Switches 2 SWITCHER FOLLOWER UNIT MONITOR AND CAMERA SELECT DIP Switches IT 1 amp 3 select the monitor to be followed TABLE 1 OFF 1 8 position DIP Switch Cnt wool Molo lolol AAA 200000000 A ss ld sd AA400 2 200 00 200 00 20C0 00 00 00 00 00 00 00 4 00
3. PRAT AAS CR AIS GROUP2 ee ae S DN HRY ABLABLABLABE ABZABLABLABL 120V 60Hz G1IN G1 OUT G2IN G2 OUT 914 22 4 9 0 LANDAY NOUIS UIN UU nn WY ABLABLABHLABH Figure 3 2031 Relay Groups 1 2 9 A B A B A B t b 0 b d b 0 ELA FLA G1 IN G1 OUT A B A B 9 Figure 4 2031 Relay Contacts Group 1 CONNECTIONS Relay Connections The 2031 Switcher Follower provides relay closures only they are not intended to supply power Two groups GROUP 1 and GROUP 2 of four 12 pin relay connectors are provided on the rear panel see Figure 3 Each group provides connections for double pole relays The two groups provide 32 pairs of relay closures Figure 4 llustrates the internal 2031 relay interconnections for Group 1 relays The relay connections to the unit must be made with shielded 2 wire twisted pair 22 AWG or heavier gauge wire or equivalent The shield wire is to be connected to the grounding terminal Each set of three pin connections is labeled with a relay number from 1 through 32 corresponding to one of the monitors of the monitor group s selected Each pin within one of the numbered sets 1s also labeled under the connector with an A a B and a ground symbol The A and B pins on each connection are the contacts for on
4. Figure 4 DIP Switch Location on PCB 2031 2031 2031 BWS BW BWS g a nd Ll OTHER CODE LINES CODE DISTRIBUTOR T 2120OHM TERMINATION Figure 8 Code Daisy Chain Configuration OPERATION After completing the Control Input connections plug in the power cord When the 2031 receives a valid code through the Control Line input the green Data Line LED illuminates The illumination of the Data Line LED is confirmation that the relays associated with a particular monitor or camera are opening and closing as each particular monitor or camera is called For 1650A operation there can be a maximum of four control lines The first control line 1s for monitors 1 8 and cameras 1 64 The second control line 1s for monitors 1 8 and cameras 65 128 The third control line is for monitors 9 16 and cameras 1 64 The fourth control line is for monitors 9 16 and cameras 65 128 When setting the DIP switches enter the actual monitor and camera group 1 e monitor 12 cameras 1 64 GROUP 1 contacts for cameras 1 16 If the DATA LINE LED does not illuminate check for proper operation of the 1995 1996 or 1024 CPU Check all your connections If all the connections are as they should be and the 2031 still does not operate properly unplug the 2031 and remove the top cover Check the DIP switch on the main printed circuit board All switches should be in the OFF position Refer to the illustration
5. VALID CODE LED POWER INDICATOR DIP SWITCH SELECTION FOR CAMERA GROUPAND MONITOR COMPATIBLE WITH EITHER DATA LINE OR CONTROL CODE UNIVERSAL MOUNT CABINET IF YOU ENCOUNTER ANY PROBLEMS OPERATING THIS UNIT OR NEED TECHNICAL ASSISTANCE CALL OUR SERVICE CENTER AT within the United States 1 800 442 2225 outside the United States 845 624 7600 INSTALLATION INSTALLATION This installation should be made by qualified service personnel and should conform to all local codes Safeguards must be taken to avoid unintentional operation by employees and maintenance personnel working about the premises by falling objects by customers by building vibration and by s milar causes The cabinet of a 2031 Switcher Follower may be surface or rack mounted in any convenient location with adequate ventilation For proper ventilation allow at least three feet 1m from the rear of the racks to any wall and one EIA rack height 1 3 4 inches between units Mounting The 2031 1s shipped with mounting ears flush with the front panel and can be mounted to the front of a standard 19 inch rack The mounting ears of the 2031 can also be placed such that they are flush with the rear panel This allows the 2031 to be mounted in a rack equipped with mounting channels The unit can also be surface mounted Mount the ears so that they are either flush with athe top or bottom covers of the unit or offset from the covers Opti
6. 00 00O0m 0 0 0 0 0 0 0 0 20 20 0 0 0 0 20 0 0 0 0 0 0 0 0 0 0 0 20 0 0 0 0 0O0 TC CAM 1 16 17 32 33 48 49 64 65 80 81 96 97 112 113 128 129 144 145 160 161 176 177 192 193 208 209 224 225 240 241 256 257 272 273 288 289 304 305 320 321 336 337 352 353 368 369 384 385 400 401 416 417 432 433 448 449 464 465 480 431 496 497 512 513 528 529 544 545 560 561 576 577 592 593 608 609 624 625 640 641 656 657 672 673 688 689 704 705 720 721 736 737 752 753 768 769 784 785 800 801 816 817 832 833 848 849 864 865 880 881 896 897 912 913 928 929 944 945 960 961 976 977 992 993 1008 1009 1024 4 INSTALLATION DIP Switches 2 amp 4 select the camera block CONNECTIONS SELECT DATA LINE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 GROUP le ABCDEF aBlaplaplapl ABLABLABlABL ABLABLABLABL PWR ON OFF 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 OUT DATA Y ABCDEF lo e eee ecc o le eee e e SCA AI CAAA IAA INA ADR
7. Amps at 30 VDC resistive load Power through the relays is not supplied by the 2031 HOLD DOWN SCREWS Figure 5 Typical 12 Pin Connector Data Line Connections A DATA LINE is connected from the DATA LINE OUT BNC on a Matrix Bay to the DATA LINE IN BNC on the rear panel of the Switcher Follower Older 1995 systems used the term LAN IN OUT Use a good grade RG 59 video cable Belden 8241 or equivalent The DATA LINE OUT BNC on the Switcher Follower must be fitted with a 75 ohm BNC terminator or if used to loop to other DATA LINE controlled equipment 1t must be terminated at the end of the run The LED labeled DATA LINE on 2031 will illuminate when valid code 1s received on the Data Line DATA LINE Input After completing the Data Line connections plug in the power cord When the 2031 receives a valid code through the Data Line inputs the green Data Line LED illuminates The illumination of the Data Line LED is confirmation that the relays associated with a particular monitor or camera are opening and closing as each particular monitor or camera 1s called If the DATA LINE LED does not illuminate check for proper operation of the 1995 1996 or 1024 CPU Check all your connections If all the connections are as they should be and the 2031 still does not operate properly unplug the 2031 and remove the top cover Check the DIP switch on the main printed circuit board All switches should be in the OFF position Refer to th
8. Blue Hill Plaza 25 Floor Pearl River New York 10965 USA Declares that the product listed below Name Type Switcher Follower Model Number AD2031 1 complies with all applicable directives as demonstrated by conformance to the following Product Specifications Safety EN 60950 1992 50130 4 1995 EN 55022 1994 Class B EN 61000 3 2 1995 EN 61000 3 3 1995 EN 61000 4 2 1995 EN 61000 4 3 1996 EN 61000 4 4 1995 EN 61000 4 5 1995 EN 61000 4 6 1996 EN 61000 4 11 1994 Supplementary Information The products herewith comply with the requirements of the Low Voltage Directive 73 23 EEC as amended by 93 68 EEC and the EMC Directive 89 339 EEC as amended by 93 68 EEC Pearl River NY USA 15 December 2000 YE pen Harold D Johnson Ph D Director of Engineering European Contact Sensormatic France S A 7 rue Alexis de Tocqueville Parc de Haute Technologie 92183 ANTONY CEDEX SPECIFICATIONS Electrical Ratings AD2031 120 VAC 50 60Hz 15 W AD2031 1 230 VAC 50 60Hz 125 mA Relay Contact Ratings 0 6 A at 24 VAC 2 0A at 30 VDC Mounting Free Standing or Rack Mount Weight 7 lbs 1 4 kg Dimensions 3 5 Hx 17 W x 8 D 89 x 432 x 203 mm Sensormatic Video Systems Divsion One Blue Hill Plaza Pearl River New York 10965 845 624 7600 Technical Support Center 800 442 2225 FAX 845 624 7685 8000 1823 01 Revision A December 2000 Printed in USA
9. 2031 SWITCHER FOLLOWER Installation and Operating Instructions The 2031 Switcher Follower can be used with all American Dynamics Matrix Switching Systems employing control codes from 1650 2150 a 1995 1996 2050 or 1024 Systems The 2031 Switcher Follower 15 used to provide simultaneous audio callup of a camera site when the video from that site 15 called to a monitor Other uses include the operation of panel displays showing called or alarmed camera sites The software firmware furnished with this equipment is confidential to and is copyrighted by SENSORMATIC ELECTRONICS CORPORATION It 15 not to be copied or disclosed in any manner without the express written consent of SENSORMATIC The software firmware is furnished to the purchaser under a license for use on a single system Information furnished by SENSORMATIC is believed to be accurate and reliable However no responsibility is assumed by SENSORMATIC for its use nor for any infringements of other rights of third parties which may result from its use No license s granted by implications or otherwise under any patent or patent rights of SENSORMATIC Copyright 2000 by Sensormatic All rights reserved AMERICAN The installation of this product should be made by qualified service personnel and should conform to all local codes RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVERS OR BACK NO USER SERV
10. IABL ABCDEF ON mmm OFF 9999 BWS DATA LINE n OUT 9 10 11 12 0000000000090 AAW VW ABLABlLaABlaBL 26 28 0000000009090 13 14 15 16 0000000009090 ABLABLABLABL 25 27 29 30 31 32 999 o o o o o o o o DAAD NS INS IN NS NAD ABLABLABLABdI NANNI NIS IN AN IN ABLABLABLABL 120V 60Hz C2 G1IN G1 OUT G21N G2 OUT OOOO ABLABLABLABL Figure 1 2031 Switcher Follower DESCRIPTION The 2031 Switcher Follower is used to provide simultaneous relay closures corresponding to a camera when it 15 called to a monitor Uses incluse the audio callup or operation of panel displays showing called or alarmed camera sites etc The 2031 receives data from either a LAN output of a 1995 a DATA LINE output of a 1996 or the Control Code output of either a 1600 1650 or 2150 System If the 2031 operates via control code a dip switch located on the main printed circit board is used to select the Control Code mode The 2031 then filters the incoming codes for either camera group or Monitor The unit contains 32 addressable normally open relays The 32 relays can be grouped in series or in two alike groups of 16 Each of the two groups can control 16 relays following one monitor and 16 cameras FEATURES The 2031 Switcher Follower has the following features SCREW TERMINAL WIRE CONNECTORS LED INDICATOR FOR
11. ICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the product WARNING To reduce the risk of fire or shock hazard do not expose this product to rain or moisture This equipment has been tested and found to comply with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation UNPACKING AND INSPECTION Unpack carefully This is an electronic product and should be handled as such Compare the items received with the packing list with your order Be sure to save 1 The shipping cartons and insert pieces They are the safest material in which to make future shipments of the product The IMPORTANT SAFEGUARDS sheet 3 These Installation and Operating Instructions y MAINTENANCE User maintenance of this unit is limited to externa
12. e illustration at right CONNECTIONS Control Code Line Connections The 12 pin terminal connector located at the lower left side of the rear panel 15 used for Control Code connections The connector 1s labeled B W and S The B is for the BLACK code wire the W is for the WHITE code wire and the S is for the SHIELD wire CAUTION Due to the presence of non insulated components with hazardous voltages the following internal adjustments should be performed by qualified service personnel only If the 2031 Switcher Follower is used with Control Code remove the top cover of the unit and locate the DIP switch on the printed circuit board see Figure 6 below Set the eighth switch position of this DIP switch to the ON position This setting enables the use of Control Code in the 2031 Note As shipped the 2031 1s set to operate in the Data Line mode this switch is set to the OFF position Control Code lines must be terminated in 120 ohms Check the last unit on each line to ensure that 120 ohm termination 1s present Intermediate units on a Control Code line must not have 120 ohm termination To remove the termination of the 2031 code line jumper J32 must be removed from the main PCB See Figure 6 for the location of this jumper Note As shipped the 2031 15 set for 120 ohm termination this jumper is inserted 81 120 ohm Termination Jumper J32 12345678 gt Dip Switch Power Cord F
13. e side of each double pole relay The contacts for the other side of each relay are connected to the common Group connectors next paragraph The ground pin is provided for shielding One 12 pin connector on the lower right of the 2031 rear panel contains the common connections for each relay group Each set of pins is labeled with the group number G1 IN Gl OUT G2 IN and G2 OUT and each pin is labeled with an A B and ground The A and B pins are common contacts for the other side of the double pole relays Gl IN and OUT are connected to relays 1 16 see Figure 4 and G2 IN and OUT are connected to relays 17 32 The Group IN connections are used for determining the function of the associated relays such as providing a user supplied voltage a short to ground or a unique signal on relay activation The Group IN pins can also be used as inputs from cascading 2031 units The Group OUT connections are used to connect the associated relays to a single responding device such as a speaker or an indicator light or for cascading to additional 2031 s For ease of attaching to external equipment each connector is supplied with a mating screw terminal connector shown in Figure 5 Insert the signal and shield wires into the slots of the mating connector and tighten the hold down screws When all lines have been connected insert the 12 pin connectors into the rear panel mating terminals The relay contact ratings are 0 6 Amps at 24 VAC or 2
14. igure 6 DIP Swich Location on PCB CONNECTIONS AND OPERATION Control Code Line Connections In switching systems using Contol Code the Switcher Follower must be connected to the code line that contains the cameras and monitor to be followed Each code line contains data for 64 cameras and eight monitors for 1650 systems and a maiximum of 32 cameras and five monitors for 2150 systems The Control Code line connections to the Switcher Follower must be shielded 2 wire twisted pair Belden 8760 for plenum use Belden 88760 or equivalent Code Lines are NEC Class 2 low voltage circuits Where local codes permit installation in conduit is not required Avoid installation near high voltage or other potential interference sources Multiple 2031s can be connected in a Star configuration to a Control Code distribution unit 1691 or 2091 See Figure 7 For this connections each 2031 must have a 120 ohm termination A maximum of three Control Code devices can be Daisy Chained on a single code line When devices are daisy chained do not terminate the control line with intermediate devices In addition make sure the intermediate equipment does not contain a 120 ohm terminating resistor If it does remove it see page 5 See Figure 8 for a daisy chained configuration 2031 2031 2031 BWS BWS BWS T T OTHER CODE LINES CODE DISTRIBUTOR T 120 OHM TERMINATION Figure 7 Code Star Configuration
15. l cleaning and inspection For specific recommendations refer to the IMPORTANT SAFEGUARDS sheet packaged with this product INSTALLATION AND SERVICE If you require information during installation of this product or if service seems necessary contact the Sensormatic Repair and Service Department at 800 442 2225 You must obtain a Return Authorization Number and shipping instructions before returning any product for service Do not attempt to service this product yourself Opening or removing covers may expose you to dangerous voltages or other hazards Refer all servicing to qualified personnel QA301D Table of Contents Des EP One eee 1 all l Installation eese nnns 2 MOUNDO 2 Monitor Camera 1 1 2 DIP ee 2 Connections Relay 4 Data Line 5 Data Eine Input 5 Control Code Line Connections 5 OBER ON UT T T POW CL o QUITO 7 Op raune usa 1 Typical System Connections Appendix PSC CA ONS oot hart back page DESCRIPTION o 1 2 3 4 5 6 7 8 GROUP 1 ABCDEF ABlaABlABlABL aBlaBlaBlasBl PWR O ON or 7 8 19 20 22 B 24 ABCDEF 99 000000009090 0000000090090 NAS ANNA NANI NANSA A DIO ANN NAD NAD GROUP2 a ABLABLABLABL ABLABLAB
16. ll illuminate and glow steadily If it flickers there may be a problem with the Control Input line POWER SOURCES APPENDIX 2031 SWITCHER FOLLOWER CHANNELB CHANNELA CAMERA 1 1 2 3 4 BLA BA DATALINE LAN FROM CPU SELECTS MONITOR AND CAMERA GROUP TO FOLLOW ELECT DATA LINE ABCDEF 5 6 9 7 10 8 13 11 14 12 15 16 y GROUP 1 OFF MM 9 9 9 9 9 4 4 4 4 4 4 44 ooo IN ascoer A BRAB AB ABHE ABRABRABRABR ABRABRABRABR ABRABRABRA BA 1 d N 17 18 2119 22 20 283 284 29 27 30 28 081 32 DATA ABCDEF 9999999990990 9999999909090 9999999990909 9999999990909 GROUP 2 etr ABRFABRABRABR ABRABRABRABR ABRABRABRABR ABRABRABRA BR ABGDEE G1 IN G1 OUT G2IN G2 OUT Ninnnnnnnn AN CONTROL CODE INPUT G1 OUT G2IN G2 OUT 1 High Speed DATA OUT to Additional 2031s or Bays CHANNELB CHANNELA TYPICAL SYSTEM CONNECTIONS 2031 SWITCHER FOLLOWER
17. mally the 2031 should be located near the Switching Systems 1995 1996 2050 1024 or near the Control Code Line of a 1600 1650 or 2150 Switching System Avoid heat sources or poorly ventilated racks DIP Switch 1 DIP Switch 2 DIP Switch 3 DIP Switch 4 Monitor Camera Select The DIP switches are also used in the 2031 to determine monitor and camera group selections DIP Switches The four 8 position DIP switches located on the rear of the 2031 under the label SELECT are used to determine monitor and camera group selections The top two DIP switches 1 amp 2 set the parameters of the GROUP 1 relays The lower two DIP switches 3 amp 4 set the parameters of the GROUP 2 Relays The configuration of the paur of 8 positions DIP switches 1 amp 2 or 3 4 determines the monitor to be followed 1 64 and the camera group to be followed in groups of 16 All the switches are programmed in binary The first and third switches are programmed to correspond to the desired monitor The second and fourth switches are programmed to correspond to the desired camera block in groups of 16 TABLE 1 shows the complete correspondence of DIP switch settings to the monitor and camera numbers Note The two groups can be set to two different monitor and camera numbers if desired LECT 4 5 6 7 8 DATALINE 9 10 11 12 13 14 15 16 ON OFF GROUP1 IN 1 OUT
18. on page 5 for this DIP switch location If the green code LED is flickering the code lines may be backwards Try reversing the black and white code lines In operation with 1650A 1995 1996 and 1024 systems the 2031 senses jumps between groups of 64 cameras When going from one group to another the 2031 will place one group in the OFF state open all relays when going to the next group of 64 cameras Power Sources DO NOT CONNECT THE EQUIPMENT TO A POWER SOURCE UNTIL READY TO POWER UP Make all connections to the 2031 data line or code input and relay connections and set the DIP switches prior to power up The 2031 Switcher Follower does not contain an On Off Switch The socket outlet shall be located near the equipment and shall be readily accessible The 120V units are supplied with a pendant 3 wire cord and plug for mating to the primary source outlet The 230V units are supplied with a Euro style IEC 320 type inlet A suitable detachable cord should be connected between the IEC 320 inlet and the power source The cord should conform to all national and local use code requirements Switcher Followers are available in two models depending on the power source to be used AD2031 120 V 50 60Hz AD2031 1 230 V 50 60Hz Operating Indicators A green POWER LED power indicator located on the rear panel illuminates when power is applied When the unit is receiving valid code the green DATA LINE LED on the rear panel wi

Download Pdf Manuals

image

Related Search

Related Contents

Extrait et revue de presse - Co-bay  図面(PDF:1759KB)  Mode d`emploi de la Boîte de Couplage LDG AT  Video Recording Kit User Guide  Samsung RF265 Refrigerator User Manual  Eton FRX3  Belkin iPod classic Leather Folio  MODE D`EMPLOI pour voter de manière électronique pour    Polycom VVX300 / VVX310 / VVX400 / VVX410  