1. Backset A and CTC distance B can be taken from the designation of the lock It is based on the following schema Example 809 12 72 65 L8 backset A 2 CTC distance B 4 type number Attention The dimensions B C and D depend on the cylinder form the lock has been set up for European profile cylinder Locking bit position of profile cylinder max 30 below Maximum air gap to striking plate 4 5 mm 33 A 41 1 Ma zeichnung Modell 809 Dimensioned drawing model 809 D00086G0000100 34 57_ 62 Dornmass 60 65 mm EN AS Rese Ara os REEL ETC RK RR KO PSSS ISSIS IRSIY 0065060500 SSSR RRR ING SSSR RSCG ORR RRR LEERE LEEREN ae R K 29 RS 2 6 lt 0 xX lt lt SL 4 L gt 16 6 XXX RR RZ RR 8 RL Q LS lt lt gt gt X XS ZI 0 RX DS RR D x IX lt lt Q Xx RS 0202020202020220 gt SPO 55055 6 x SS x gt Xx x gt OR RR OR SR SR lt gt OL x OR gt x Xx x gt lt lt gt Q X RL x Q lt SS K Ze K X L LX maximal 4 5 mm Einbauzeichnung Metall Stulp aufgesc
2. In this way opening the door from the outside can be made possible or impossible by making contact Most simply this can be effected by a push button Of course this function can also be realized by an electronic access control system such as a magnetic card reader a door code unit or similar 21 The coil actuating the outside handle can also be energized continuously Thus a door equipped with this lock can be released permanently e g for certain hours of the day by means of a switch or a timer Monitoring Contacts The effeff electric lock 809 integrates four monitoring contacts which are potential free changeover contacts All connections are laid to terminals in the wiring space of the lock The switching moments of the contacts are exactly timed in order to offer the greatest possible variety of functions and reliable monitoring The bolt switch contact switches when the bolt is still extended by about 90 The outside handle contact switches when the outside door handle is operated The inside handle contact switches when the inside door handle is operated If the outside handle is operated while it is actuated electrically both handle contacts switch however the outside handle contact switches before the inside handle contact Both contacts switch clearly before the bolt switch contact reacts The profile cylinder contact switches only if the profile cylinder is operated after the bolt has been retracted Att
3. 24 The Electric Lock for Security in Fail Unlocked Version 2 7 einen 25 Special Versions ee eee cece ances 26 Mounting and Installation es as ae 27 Security Regulations ee eee eee 27 Information on Installation we ae eee 28 Installation of the Lock ue use 28 Cable Layout ee cee cee eee 28 Different Versions of The lock ae eee 29 PNS oe 30 Technical Dale o4 iii 31 Electrical Connection Le eee eee eee eee 31 Connection Diagramm _ ee eee ae eee 32 Dimensioned Drawings eses crre eis sehen iE ats teh 33 Dimensioned Drawing Model 809 ue 34 Installation Diagramm Wood ae ase 35 Installation Diagramm Metal ae eee 36 Striking Plates eee eee eee neces 37 wiring space cover and pull relief faceplate latch bolt follower two part control latch lock bolt cylinder holes for cutout furniture Screws Illustration non binding Subject to technical alterations without prior notice 20 Function and Operation General Function The effeff electric lock 809 represents a completely new combination of various lock functions It has the usual functions of a normal lock equipped with a lock bolt and a key operated latch bolt Furthermore it unites automatic locking and panic function and it offers the possibilities of electric e
4. der Ruhestromausf hrung in keinem Fall in T ren im Verlauf von Rettungswegen eingebaut werden Da hier beide Dr cker ber den starren Dr ckerstift fest verbunden sind gilt das weiter oben ber die Funktion des Au endr ckers gesagte hier sinngem f r beide Dr cker Montage und Installation Sicherheitshinweise Bei der Montage und Installation des Sicherheitsschlosses 809 sind unbedingt einige Sicherheitsregeln zu ber cksichtigen Diese m ssen eingehalten werden da anderenfalls das Ger t besch digt werden kann oder Gefahren f r den Benutzer entstehen Am Schlo d rfen keinerlei Ver nderungen vorgenommen werden Bis zum endg ltigen Einbau d rfen die Aufkleber welche die Zylinderaufnahme abdecken nicht entfernt werden Sie verhindern das Eindringen von Fremdk rpern und Schmutz in das Schlo Achtung W hrend der Montage mu sichergestellt werden da die T r nicht geschlossen werden kann und da sie sich auch nicht selbstt tig schlie en kann Vergessen Sie nicht da es sich um ein selbstverriegelndes Schlo handelt das von au en ohne elektrische Ansteuerung nur mit dem Schl ssel ge ffnet werden kann Bei der Auswahl und Montage des als Gegenst ck zum Schlo zu montierenden Schlie bleches mu darauf geachtet werden da bei geschlossener T r niemals die Steuerfalle des Schlosses aus ausschlie en darf Die T r k nnte in diesem Fall nicht mehr ge ffnet werden Der
5. en durch elektrische Kontaktgabe freigegeben oder gesperrt werden Im einfachsten Fall geschieht dies durch einen simplen Taster Diese Tastfunktion kann selbstverst ndlich auch von einem elektronischen Zutrittskontrollsystem wie Magnetkartenleser T rcodeanlage oder hnlichem gegeben werden Die Spule ber die im Schlo die Aufkoppelung des u eren Dr ckers bewirkt wird ist so ausgelegt da sie auch dauernd angesteuert werden kann Eine mit diesem Schlo ausgestattete T r kann also auch ber einen Schalter oder eine Schaltuhr etwa zu bestimmten Tageszeiten dauernd freigegeben werden berwachungskontakte Im effeff Sicherheitsschlo 809 sind vier berwachungskontakte integriert die als potentialfreie Umschaltkontakte ausgelegt sind Alle Anschl sse sind im Anschlu raum des Schlosses auf Klemmen gef hrt Die Schaltzeitpunkte der einzelnen Kontakte im Laufe der Schlo bet tigung sind genauestens aufeinander abgestimmt um eine gr tm gliche Funktionsvielfalt und Uberwachungssicherheit zu erm glichen Der Riegelkontaktschaltet wenn der Riegel noch circa 90 ausgeschlossen ist Der Au endr cker Kontakt schaltet bei Bet tigung des u eren T rdr ckers Der Innendr cker Kontakt schaltet bei Bet tigung des inneren T rdr ckers Bei aufgekoppeltem Au endr cker schalten selbstverst ndlich beide Dr ckerkontakte der des u eren Dr ckers jedoch vor dem des inneren Beide Kontakte schalten deutlich v
6. Einbau des Schlosses mu spannunggsfrei erfolgen Es ist also auf Einhaltung aller Ma vorgaben und auf Winkelgenauigkeit zu achten Alle Montage und Anschlu arbeiten sind von einer Fachkraft des jeweils zugeh rigen Gewerks durchzuf hren ACHTUNG Beim Einbau des Schlosses auf die Einhaltung bauaufsichtlicher Vorschriften und eventuelle Vorgaben des T rherstellers achten Hinweise zur Montage Montage des Schlosses F r die rein mechanische Montage kann das Anschlu kabel vor bergehend vom Schlo abgenommen werden Entfernen Sie dazu die Kunststoffabdeckung des Anschlu raumes indem Sie die drei Befestigungsschrauben entfernen und die Kunststoffabdeckung nach oben abziehen Die Anschlu klemmen sind nun zug nglich so da das Kabel abgeklemmt werden kann Danach unbedingt die Abdeckung wieder einsetzen und festschrauben damit kein Schmutz in das Schlo eindringen kann Arbeiten am T rblatt wie Bohrungen Fr sungen oder hnliches d rfen niemals bei eingebautem oder eingestecktem Schlo durchgef hrt werden Der Ausfr sung f r die Schlo tasche sind die Ma skizzen zugrundezulegen Sie ist so zu dimensionieren da sich das Schlo ohne jeglichen Kraftaufwand in die Tasche einf hren l t und spannungsfrei mit dem T rblatt fest verbunden werden kann Die Tiefe der Ausfr sung f r die Schlo tasche ergibt sich aus der Summe aus Dornma A und Hinterdornma fest 33mm plus einem Zuschlag von ca 20mm f r ei
7. Elektro Sicherheitsschloss 809 Ausf hrung f r Vollt ren Dornma 60 mm und 65 mm D0008604 Sehr geehrter Kunde mit dem eff eff Sicherheitsschlo 809 haben Sie ein Ger t erstanden das h chste Sicherheitsanforderungen erf llt Dieser v llig neue Schlo typ wurde mit modernsten technischen Produktionsmethoden aus hochwertigsten Materialien und Komponenten gefertigt Seine Lebensdauer betr gt deshalb normalerweise ein vielfaches der von der Firma eff eff einger umten Gew hrleistungsfrist Voraussetzung ist jedoch da Sie einige grundlegende Regeln und Vorsichtsma nahmen beachten Nehmen Sie an dem Schlo keinerlei Ver nderungen vor Betreiben Sie das Scho nur in schlo typischer Einbaulage das hei t senkrecht eingebaut mit horizontal ausschlie endem Riegel berstreichen Sie niemals den Schlo stulp oder andere Teile des Schlosses mit Farbe oder Lack Bauen Sie das Schlo vor Malerar beiten aus K Bringen Sie keine Schmiermittel Fette oder Ole in das Schlo ein Das Ger t ist mit einer Dauerschmierung versehen die nicht erneu ert werden mu 5 Vermeiden Sie da Wasser in das Schlo eindringt oder sich im Schlo bereich Kondenswasser bildet Lassen Sie alle Montage und Anschlu arbeiten von einer Fach kraft des jeweils zust ndigen Gewerks ausf hren z B Schreiner oder Schlosser f r den Einbau Elektroinstallateur f r den elektri schen Anschl
8. SiiW 312 DIN LEFT DIN RIGHT mirror image DIN RIGHT mirror image D00086G0000500 D00086G0000600 39 effeff Fritz Fuss GmbH amp Co Kommanditgesellschaft auf Aktien Bildstockstra e 20 D 72458 Albstadt Telefon 49 74 31 1 23 0 Telefax 49 74 31 1 23 240 info effeff com www effeff com An ASSA ABLOY Group company ASSA ABLOY
9. altkontakt schaltet bei ca 90 ausgeschlossenem Riegel gezeichnet Riegel ausgeschlossen S 2 Endschalter T r Au endr cker schaltet nur bei Bet tigung des T r Au endr ckers S 3 Endschalter T r Innendr cker schaltet bei Bet tigung des T r Innendr ckers S4 Profilzylinderkontakt schaltet nur bei Bet tigung des Profilzylinders Der die Spule ansteuernde Kontakt ist bei der Arbeitsstromversion als Arbeitskontakt Schlie er bei der Ruhestromversion als Ruhekontakt Offner aufzuschalten Hinweis s mtliche Kontaktstellungen sind unbet tigt gezeichnet bei Bet tigung des aufgekoppelten Au endr ckers werden beide T rdr ckerkontakte geschaltet der Endschalter des Au endr ckers schaltet vor dem Enschalter des Innendr ckers D0008603A0000101 Ma und Einbauzeichnungen sind ab Seite 33 wiedergegeben 16 Electric Security Lock Model 809 Version for solid doors Backset 60 mm and 65 mm D0008604 Dear Customer The effeff electric lock for security 809 satisfies the highest security requirements This completely new type of lock is produced by the most modern technical production methods of high quality materials and components Its service life is usually much longer than the guarantee period granted by effeff provided that some fundamental rules and regulations are observed Do not modify the lock in any way The lock must be mounted in the c
10. be prepared in accordance with the dimensions below It must be possible to insert the lock into the lock pocket without expenditure of force and to fix it to the door leaf without strain by using the bore holes in the faceplate The depth of the recess for the lock pocket is calculated by adding backset A and rear backset always 33 mm plus an addition of about 20 mm for a cable loop check again Cable Layout The connecting cable of the effeff electric lock 809 must be laid in the door leaf from the lock side to the hinge side if possible in a conduit with an inner diameter of at least 7 mm Any loops should be as large as possible If a conduit cannot be fitted e g because the lock is mounted later in an existing door the cable must be laid particularly carefully Edges must be rounded off to prevent damage to the cable covering From the door leaf to the frame the cable must be laid in a flexible bridging cable which is firmly fixed to the door leaf and the frame Please observe the respective mounting instructions in this regard 28 Different Versions of the Lock handle with panic function electrically controlable handle The version of the lock has to be determined according to the opening direction of the door and to wether the inner performs the panic function and the outer handle is electrically controllable or vice versa The last 15 figure of the type number indicates the version of t
11. contact it can be controlled whether the lock has been operated in order to leave or to enter the room as the contacts switch at different moments This can be evaluated by appropriate monitoring systems e g in order to control the number of persons in a room 23 Operation in Connection with an Additional Escape Door Control System If unauthorized opening of the door from the inside has to be prevented or is to trigger an alarm the effeff electric lock 809 is particularly suitable to be used in connection with an escape door control system As usual the escape door control system is installed as an additional locking system Consequently the door can only be opened from the inside if the escape door control system has been released before The advantages of a combination of an escape door control system and an effeff electric lock 809 are It is not necessary to install a key switch on the outside of the door this function can be realized by means of the profile cylinder contact of the effeff electric lock 809 Seen from the outside the door is doubly secured as it is locked by the escape door control system and by the effeff electric lock 809 Authorized opening of the door from the outside by means of the key requires no additional devices and a normal operation like with any lock with key operated latch bolt is possible Seen from outside the door is still secured by the lock in the event of a power failure Combined t
12. d beim Sicherheitsschlo 809 der Riegelkontakt eingesetzt Er meldet an die Uberwachungselektronik T r geschlossen und verriegelt Soll die berwachung zus tzlich gegen bewu te Sabotage oder versehentliche Fehlausl sung gesichert werden so kann zu diesem Kontakt ein T rkontakt in Reihe geschaltet werden Bereichswechselkontrolle Mit Hilfe des Au en und des Innen dr ckerkontaktes kann unterschieden werden ob das Schlo zum Verlassen oder zum Betreten des Raumes bet tigt wurde da die Kontakte zu unterschiedlichen Zeitpunkten schalten Dies kann von entsprechend konzipierten Uberwachungssystemen ausgewertet werden um zum Beispiel die Anzahl der in einem Raum befindlichen Personen zu steuern Betrieb mit zus tzlicher Fluchtt rsicherung Soll die unbefugte Begehung der T r von der Innenseite verhindert bzw zwingend mit einer Alarmausl sung verbunden werden so l t sich das eff eff Sicherheitsschlo in idealer Weise mit einer Fluchtt rsicherung verbinden Die Fluchtt rsicherung wird dabei wie blich als zus tzliche Verriegelung angebracht Dies hat zur Folge da die T r auch von innen nur ge ffnet werden kann wenn zuvor die Fluchtt rsicherung freigeschaltet wurde Die besonderen Vorteile einer Kombination aus Fluchtt rsicherung und Sicherheitsschlo 809 bestehen darin da die Installation eines Schl sselschalters an der Au enseite der T r entfallen kann diese Funktion kann ber den Profilzylinderkontak
13. eff Sicherheitsschlo 809 erfordert einen Panikbeschlag mit geteiltem Dr ckerstift und beidseitig fest drehbar in den Schilden gelagerten Dr ckern Es wird empfohlen Sicherheits Dr cker garnituren einzusetzen wie sie f r Brandschutz und einbruchhem mende T ren angeboten werden Die Firma effeff bietet geeignete Beschlagsgarnituren einschlie lich allen erforderlichen Zubeh rs an Bei der Montage der T rschilde und Dr cker ist darauf zu achten da alle Teile spielfrei und spannungslos auf dem T rblatt fixiert werden Bitte beachten Sie die Montageanweisungen des jeweiligen Herstellers und gegebenenfalls auch die bauaufsichtlichen Vorschriften L nge a AuBenstift g Bei der Montage mu darauf geachtet werden da beim a H Dr ckerstift zwischen u erem und innerem Stiftteil unterschieden wird Die beiden Stiftteile sind meist durch eingepr gte Buchstaben gekenn zeichnet HA Freilaufseite mm LIN Panikseite u Der Dr ckerstift mu so montiert werden da die Verbindungs schraube zur Panikseite zeigt Die L nge der Stifte ist abh ngig von der T rblattst rke der horizontalen Schlo position der St rke des ver wendeten Turschildes und der erforderlichen Eingreiftiefe in den L T rdr cker Technische Daten Riegelausschlu 20 mm Riegelh he 33 mm Riegelst rke 8mm Stulpma e 20 24 x 235 x 3 mm Material von Fa
14. ention The locking cylinder canot be turned around completely The lock bolt cannot be extended by means of the cylinder 22 Special Functions By means of some examples showing the operation of the lock in connection with overriding control and monitoring systems its functions and possibilites are explained Of course not all possibilites of use can be named here Access control and door open monitoring Access control by means of the effeff electric lock 809 is not considerably different from access control realized by means of an electric door release From the mechanical point of view the main advantage is that the closed door is secured by the latch bolt and the lock bolt whereas regarding other solutions usually only the latch bolt secures the door Corresponding to the triggering of the door release coil the lock coil actuating the outside handle as long as it is energized is triggered Most access control systems integrate a door monitoring function i e a monitoring contact closes if the door is still open after a certain period has expired For this purpose the bolt switch contact of the effeff electric lock 809 is used It signals to the electronic controller that the door is closed and locked The monitoring function can be protected against sabotage or erroneous activation by connecting a door contact and the bolt switch contact in series Area change control By means of the outside handle contact and the inside handle
15. h die Steuerfalle die sich zwischen Schlo falle und Schlo riegel befindet ist jedoch auch abh ngig von der Position der SchloBfalle Nur bei teilweise zur ckgedr ckter Schlo falle kann auch die Steuerfalle bet tigt werden Dadurch wird eine versehentliche Ausl sung der Verriegelung bei ge ffneter T r weitgehend ausgeschlossen Wird das Schlo ber Dr cker oder Schl ssel entriegelt die T r jedoch nicht ge ffnet so l st die Aufhebung der Bet tigung die automatische Wiederverriegelung aus Panikfunktion bietet ein Schlo das in jedem m glichen Zustand von innen ohne zus tzliche Hilfsmittel ge ffnet werden kann Das hei t da beim Sicherheitsschlo 809 die Bet tigung des inneren Dr ckers sowohl die Schlo falle als auch den Riegel zur ckschlie t so da die T r von innen in jedem Fall ge ffnet werden kann Zutrittskontrolle Beim effeff Sicherheitsschlo 809 wurde diese Funktion erstmalig in einem selbstverriegelnden Panikschlo integriert Seine Dr ckernu ist zweigeteilt und deren u erer Teil im Ruhezustand im Leerlauf Der zu verwendende Dr ckerstift mu ebenfalls zweigeteilt und seine beiden Teile frei gegeneinander drehbar sein Dies hat zur Folge da der auf der Au enseite der T r angebrachte Dr cker zun chst keine Funktion hat Er kann jedoch durch elektrische Ansteuerung aufgekoppelt werden und hat dann die gleiche Funktion wie der Innendr cker Dadurch kann die T r f r die Begehung von au
16. hat from the outside it can only be opened by means of the key if it is not energized When selecting and mounting the faceplate which is fitted as a mating part of the lock make sure that the control latch of the lock cannot be extended when the door is closed because then the door could not be opened any more The lock must be installed without strain All dimensions and angles indicated must be observed Mounting and electrical connection must be carried out by a qualified technician ATTENTION The lock must be installed in accordance with the Building Inspection Authority requirements or equivalent in the country of use and in accordance with the regulations of the door manufacturer 27 Information on the Installation of the Lock Mounting and electrical connection must be carried out by a qualified technician Installation of the Lock Before mounting the lock the connecting cable can be removed temporarily For this purpose take off the plastic cover of the wiring space by releasing the three fixing screws and pulling the plastic cover upwards The terminals are now accessible and the cable can be squeezed off To prevent dirt penetrating the lock the cover must be fitted again and fastened with the screws Preparation of the door leaf such as drilling milling or similar must never be carried out after the lock has been mounted or inserted into the lock pocket The recess for the lock pocket must
17. he lock in accordance with the above drawings 29 Fittings The effeff high security lock 809 requires panic fittings with split handle pin and handles fixed with high quality bearings into the escutcheons It is recommended to use security handles suitable for fire rated and burglar resistant doors effeff offers appropriate fittings as well as any required accessories The escutcheons and handles must be fixed without any free play or bending stress onto the door leaf Please observe the installation instruktions of the manufacturer and if necessary the public building regulations as well length outer pin Please note that there is a difference between the inner and the outer part of the handle pin Normally both parts are marked with imressed letters The handle pin must be installed in such a way that the connecting screw points to the panic side The length of the pins depends on the thickness of the doorleaf the horizontal position of the lock the thickness of the escutcheon used and the required depth to engage the handle 30 freewheeling side panic side LO Technical Data lock bolt extension travel 20 mm lock bolt height 33 mm lock bolt thickness 8mm faceplate dimensions 20 24 x 235 x 3mm latch bolt material lock bolt material steel faceplate material stainless steel The effeff electric lock for security 809 satisfies the
18. hraubt Installation Diagram metal faceplate surface mounted D00086G0000300 36 Schlie bleche Striking plates Achtung Aufschlagkante f r Schlo falle und Steuerfalle m ssen fluchten Der Abstand zwischen Schlie blech und Schlo stulp darf 4 5 mm nicht berschreiten Attention The striking edge for latchbolt and auxiliary latch must align The gap between striking plate and faceplate of the lock must not exceed 4 5 mm 1012 hL C Standard Flachschlie blech 809HZ20 24 809HZ20 24 Standard flat striking plate D00086G0000400 37 Verstellbares Schlie blech 809 HZV DIN LINKS und DIN RECHTS verwendbar Details zur Montage siehe zugeh rige Montageanleitung Adjustable strike 809 HZV Mountable left or right handed See details of mounting in the mounting instructions belonging to it 38 38 5475 34 3 She 44 25 25 3 8 25 vci D0008603G0000701 190 H 44 J 40 74 N 152 Winkelschlie blech Sicherheitswinkelschlie blech 809iW066 DIN LINKS 809SiiW 312 DIN LINKS DIN RECHTS spiegelbildlich DIN RECHTS spiegelbildlich Rectangular striking plate Rectangular security striking plate 809iW066 DIN LEFT 809
19. lectronic access control and precise monitoring of the lock Automatic locking means that the lock bolt is automatically extended when the door is closed Thus the door is always locked when it is closed This function is activated by the control latch which is located between the latch bolt and the lock bolt but it also depends on the position of the latch bolt Only if the latch bolt is partly retracted the control latch can be operated So erroneous locking while the door is open is nearly impossible If the lock is unlocked by means of the handle or the key and the door is not opened automatic re locking is activated as soon as the operation is terminated Panic function means that the door can be opened from the inside at any moment without recourse to auxiliary means By operating the inside handle of the effeff electric lock 809 both the latch bolt and the lock bolt are retracted so the door can always be opened from the inside Access control The effeff electric lock 809 is the first automatically locking panic lock with access control function Its follower consists of two parts and the outer part of the follower runs at no load when it is in quiescent condition The handle pin must also consist of two parts and both parts must be rotatable against each other Consequently initially the handle on the outside of the door has no function However it can be actuated electrically and then has the same function as the inside door handle
20. lle und Riegel Stahl Stulpmaterial Edelstahl Das Elektro Sicherheitsschlo 809 entspricht den Festigkeits anforderungen der DIN 18251 Klasse 4 Nennspannung 12 V DC 100 ED 15 10 oder 24 V DC 100 ED 15 10 Stromaufnahme 12 V DC 220 mA 24 V DC 110 mA Schaltleistung der Mikroschalter Imax 1A U max 24 V L nge des Anschlu kabels 6m Schutzart eingebaut mit montiertem Zylinder IP 30 Gewicht ca 1 2 kg MaB und Einbauzeichnungen sind ab Seite 33 wieder gegeben Zum elektrischen AnschluB Der ElektroanschluB f r das Elektrosicherheitsschlo ist gem den Anschlu pl nen der ansteuernden Ger te durchzuf hren Hierbei bitte den nachfolgenden Anschlu plan zum Sicherheitsschlo 809 und die unten aufgef hrten technischen Daten beachten Insbesondere m ssen dabei folgende Daten verglichen werden Die Nennspannung der Spule im Schlo mit der Ausgangsspannung des ansteuernden Ger tes Die Leistungsaufnahme der Spule mit der Ausgangsleistung des Steuerger ts Die maximale Schaltleistung der berwachungskontakte mit der jeweils zu schaltenden Leistung Die einschl gigen VDE Bestimmungen und die Bestimmungen der rtlichen EVUs sind zu ber cksichtigen 15 Anschlu plan braun gr n grau rosa schwarz c gt 2 gt 2 2 Farbkennzeichnung Anschlu leitung rosa gelb gr n violett grau braun wei L1 Spule Polarit t und Nennspannung beachten 51 Riegelsch
21. ne Kabelschlaufe Revision Zur Kabelf hrung Das Anschlu kabel des effeff Sicherheitsschlosses mu im T rblatt von der Schlo seite zur Bandseite gef hrt werden Dies sollte wo immer m glich in einem separaten Leerrohr geschehen das einen Innendurchmesser von mindestens 7mm aufweist Etwa erforderliche B gen sollten so gro wie m glich ausgef hrt werden Sollte das Einbringen eines Leerrohres nicht mehr m glich sein wie dies z B beim nachtr glichen Einbau des Schlosses in eine bestehende T r denkbar ist mu beim Einbringen des Kabels besonders sorgf ltig gearbeitet werden Ecken und Kanten um die das Kabel gef hrt werden mu m ssen abgerundet werden damit der Kabelmantel nicht besch digt werden kann Beim bergang vom T rblatt zum Rahmen mu das Kabel durch einen flexiblen Kabel bergang gef hrt werden der beidseitig fest mit T rblatt bzw Rahmen verbunden wird Bitte beachten Sie hierzu die jeweilige Montageanleitung Schlo ausf hrungen HEE EE z d S i HER Degen 7 5 Dr cker mit Panikfunktion A Elektrisch steuerbarer Dr cker Die Ausf hrung des Schlosses bestimmt sich nach der Aufschlagrichtung der T r und nach der elektrisch zu steuernden Dr ckerseite beziehungsweise der Panikseite Alle Schl sser sind auf dem Typenschild gekennzeichnet Die letzte 15te Stelle der Typennummer bezeichnet die Ausf hrung entsprechend obiger Skizzen Beschl ge Das eff
22. nn zum Beispiel dann erw nscht sein wenn eine T r im Notfall also auch bei Stromausfall auch von au en frei begehbar sein mu was unter anderem bei Zug ngen f r Feuerwehr und Rettungskr fte erforderlich sein kann Achtung Bitte beachten Sie da das Schlo auch in Ruhestromausf hrung an einer Fluchtt re nicht so angebracht werden darf da der elektrisch angesteuerte Dr cker oben Au endr cker genannt auf der Innenseite in Fluchtrichtung montiert wird Das Schlo m te dann als elektrische Verriegelung einer Rettungswegt r eingestuft werden und unterl ge damit speziellen bauaufsichtlichen Bestimmungen In der Typenbezeichnung ist die Ruhestromausf hrung daran zu erkennen da im zweiten Teil der Typennummer immer eine 3 an erster Stelle steht Also zum Beispiel Modell 809 32 xx Alle auf den nachfolgenden Seiten angegebenen technischen Daten gelten sowohl f r die Arbeitsstrom als auch f r die Ruhestromausf hrung des Sicherheitsschlosses 809 Sonderausf hrungen F r besondere Anwendungsf lle wird vom Sicherheitsschlo 809 eine Spezialausf hrung f r durchgehenden nicht geteilten Dr cker stift gefertigt Bei dieser Sonderausf hrung ist sowohl der Innen als auch der Au endr cker im Leerlauf wenn das Schlo nicht elektrisch angesteuert ist Es wird sowohl eine Ruhestrom als auch eine Arbeitsstromausf hrung angeboten Diese Sonderausf hrung hat keine Panikfunktion darf also auch in
23. or dem Ansprechen des Riegelkontaktes Der Profilzylinderkontakt schaltet nur bei Bet tigung des Profil zylinders nach dem Zur ckschlie en des Riegels Achtung Der Schlie zylinder kann nicht vollst ndig durchgedreht werden Es kann nicht ber den Schlie zylinder verschlossen werden Sonderfunktionen Anhand einiger beispielhafter Beschreibungen des Zusammenspiels des Schlosses mit bergeordneten Steuer oder berwachungs anlagen wollen wir Ihnen die Funktionen und M glichkeiten des Schlosses noch etwas verdeutlichen Diese Aufstellung kann selbstverst ndlich nicht alle denkbaren Einsatzm glichkeiten auf f hren Zutrittskontrolle mit T r offen berwachung Eine Zutrittskontrolle mit dem Sicherheitschlo 809 unterscheidet sich im wesentlichen nicht von der bisher bekannten Art wie sie meist mit einem Elektrot r ffner realisiert wurde Der Hauptvorteil aus mechanischer Sicht ist da die geschlossene T r durch Schlo falle und Riegel gesichert ist w hrend bei bisherigen L sungen im allgemeinen nur die Schlo falle die T r sicherte Entsprechend der Ansteuerung der T r ffnerspule wird nunmehr die Koppelspule im Schlo angesteuert die den Au endr cker solange sie bestromt wird aufkoppelt Die Mehrzahl aller Zutrittskontrollsysteme enth lt auch eine T r berwachungsfunktion in der Form da ein Meldekontakt schlie t wenn eine T r ber einen bestimmten Zeitraum hinaus offen bleibt Zu diesem Zweck wir
24. orrect position i e vertically bolt must be extended horizontally Do not paint or varnish the lock faceplate or other parts of the lock Remove the lock before painting Do not use lubricants grease or oil The lock is lubricated for life Avoid water and condensation penetrating the lock Mounting and electrical connection must be carried out by a qualified technician mounting e g by a joiner or a locksmith electrical connection by an electrician Failure to observe these instructions or our general terms of warranty will invalidate the guarantee Please read the following instructions on the function and handling of the lock carefully Only if you understand how it operates and which possibilities it offers you will be able to use it to your satisfaction The electric high security lock has been approved for installation in fire rated doors Test DO 9 11 Test certificate no P 12 0090 2 97 With the exception of special types with controlled handels on both sides through square hole the lock offers panic function for the direction of exit Contents Function and Operation ae eee eee eee 21 General Function ee snnnnnnnnnnn anne 21 Monitoring Contacts a ees ees 22 Special Functions ee ee eee eee 23 Operation in Connection with an Additional Escape Door Control System eee eee eee
25. riggering of an effeff electric lock 809 and an escape door control system is possible without problems and can be realized in different ways if effeff escape door control systems are used 24 The effeff Electric Lock for Security 809 in Fail Unlocked Version The effeff electric lock 809 can also be delivered in fail unlocked version Its function concerning electrical control is exactly contrary to the function of the standard version Function of the outside handle of the fail unlocked lock Coil not energized outside handle actuated Coil energized outside handle not actuated The functional descriptions on the previous pages regarding electrical control of the lock have to be interpreted vice versa In the ground state the lock coil is continuously energized In order to open the door from the outside the circuit is interrupted This function may be required if it is necessary that a door can be opened from the outside without recourse to auxiliary means in the event of an emergency thus also in the event of a power failure e g by fire brigades or for rescue purposes Attention Please note that the lock must never be installed in an escape door in a way that the handle which is controlled electrically here named outside handle is mounted on the inside The fail unlocked version can be recognized by the type designation as the first number of the second part of the type designation of a fail unlocked lock is always
26. strength requirements of DIN 18251 class 4 nominal voltage 12 V DC 100 ED 15 10 or 24 V DC 100 ED 15 10 current consumption 12 V DC 220 mA 24 V DC 110 mA switching power of the microswitches I max 1A U max 24 V length of the connecting cable 6m type of protection installed cylinder mounted IP 30 weight approx 1 2 kg Electrical Connection The electrical connection of the effeff electric lock for security 809 must be carried out in accordance with the connection diagrams of the units which trigger the lock Please observe the following connection diagram of the effeff electric lock 809 and the technical data Furthermore the following specifications must be compared The nominal voltage of the lock coil must be compared with the output voltage of the unit which triggers the lock The current consumption of the coil must be compared with the output of the control unit The maximum switching power of the monitoring contacts must be compared with the power which has to be switched The installation of the system must comply with the electrical and electricity company regulations applicable in the country of use 31 Connection Diagram 2 oO x o FSF gt Dir Ae TE ce 2 3 c o a o 2 x on gt 23 gt 5 GD 5 38 2 0 G amp G Fe DO F o OO 09 FE D D oO 5 x oa 2 2 Q gt 53232 O Q O A 3 colours of the cable markers L1 coil pay attention
27. t des Sicherheitsschlosses realisiert werden die T r von au en gesehen doppelt gesichert ist da sie sowohl durch die Fluchtt rsicherung als auch durch das Sicherheitsschlo versperrt wird die berechtigte Begehung von au en mit Schl ssel keine zu s tzlichen Ger te erfordert und ein normaler Ablauf wie bei jedem Schlo mit Wechsel gegeben ist Die Sicherung der T r von au en durch das Schlo bleibt bei Energieausfall selbstverst ndlich erhalten Die kombinierte Ansteuerung von Elektro Sicherheitsschlo und Fluchtt rsicherung ist bei Verwendung von effeff Fluchtt rsicherungs systemen problemlos m glich und kann auf unterschiedliche Weise realisiert werden Das Sicherheitsschlo 809 in Ruhestromausf hrung Das effeff Sicherheitsschlo 809 wird auf besondere Anforderung auch in Ruhestromausf hrung hergestellt Dies bedeutet da seine Funktionsweise in bezug auf die elektrische Ansteuerung dann genau entgegengesetzt derjenigen der Standardausf hrung ist Funktion des Au endr ckers bei Ruhestromausf hrung Spule stromlos Au endr cker aufgekoppelt Spule bestromt Au endr cker nicht aufgekoppelt Die auf den vorhergehenden Seiten gegebenen Funktions beschreibungen zur Ansteuerung des Schlosses sind also sinngem jeweils in ihr Gegenteil umzukehren Die Spule des Schlosses ist im Grundzustand st ndig bestromt F r die Begehung der T r von au en wird der Stromkreis unterbrochen Diese Funktion ka
28. the number 3 e g model 809 32 xx The technical data on the following pages apply to the fail locked and to the fail unlocked versions of the effeff electric lock 809 25 Special Versions For particular applications a special version of the effeff electric lock 809 set up for a through handle pin which is not split is offered While the lock is not triggered electrically both the inside door handle and the outside door handle run at no load This version is also available with fail unlocked function This special lock has no panic function therefore it must never be installed in doors in escape routes not even the fail unlocked version As both door handles of this special lock are firmly connected by means of the rigid handle pin the explanations on the function of the outside door handle on the previous pages apply to both door handles of the special version 26 Mounting and Installation Security Regulations When installing an effeff electric lock 809 it is absolutely necessary that the following security regulations are observed in order to avoid damages to the lock or dangers for the user Do not modify the lock in any way Do not remove the foils covering the cylinder cutout before the cylinder is mounted as they prevent dirt penetrating the lock Attention While installing the lock take care that the door cannot be closed nor closes by itself Do not forget that this lock is locked automatically and t
29. to the correct polarity and to the nominal voltage S 1 bolt switch contact switches when the bolt is extended by about 90 shown bolt extended S 2 outside door handle limit switch switches only if the outside door handle is operated S 3 inside door handle limit switch switches if the inside door handle is operated S 4 profile cylinder contact switches only if the profile cylinder is operated The contact triggering the coil has to be connected as a normally open contact in the fail locked version and as a normally closed contact in the fail unlocked version Information all contact positions are shown in quiescent condition both handle contacts switch if the outside door handle is operated while it is actuated the outside door handle limit switch reacts before the inside door handle limit switch D0008603A0000201 32 Ma und Einbauzeichnungen Dimensioned Drawings Dornma A sowie Entfernung B k nnen der Typenbezeichnung des Schlosses entnommen werden Sie ist nach folgendem Schema aufgebaut Beispiel 809 12 72 65 L Dornma A 2 Entfernung B 1 Typennummer Achtung Die Ma e B C und D sind abh ngig von der Zylinderform f r die das Schlo vorgerichtet ist B C D Euro PZ 72 30 8 mm Kaba PZ 74 28 6 mm Schlie bartstellung des Profilzylinders max 30 unten links oder rechts Maximal zul ssige Falzluft Stulp Schlie blech 4 5 mm
30. u F r Sch den die durch Nichtbeachtung einer dieser Regeln entstehen m ssen wir ebenso wie bei Verletzung unserer allgemeinen Garantiebedingungen jegliche Gew hrleistung ablehnen Wir bitten um Ihr Verst ndnis Bitte lesen Sie die nachfolgenden Informationen zur Funktion und Hand habung des Schlosses aufmerksam durch Nur wenn Sie genau verstehen wie das Ger t funktioniert und welche M glichkeiten es bietet werden Sie seine Funktionen zu Ihrer Zufriedenheit nutzen k nnen Das Elektro Sicherheitsschlo 809 ist zugelassen zur Verwendung an Feuerschutzt ren Pr fkennzeichen DO 9 11 Pr fzeugnis Nummer P 12 0090 2 97 Mit Ausnahme der Sonderausf hrungen mit beidseitig steuerbarem Dr cker durchgehender Vierkant bietet das Schlo f r eine Begehungsrichtung Antipanik funktion INHALT Funktion und Bedienung ae eae nennen 5 Zur Funkliam stagnated age 5 berwachungskontakte ae ees 6 Sonderfunktionen ee eee cee eee 7 Betrieb mit zus tzlicher Fluchttursicherung 8 Das Sicherheitsschlo 809 in Ruhestromausf hrung 9 Sonderausf hrungen eee eee 10 Montage und Installation as ss as ae 11 Sicherheitshinweise ee eee eee 11 Hinweise zur Montage as ces oe 12 Montage des Schlosses uu ue 12 Zur Kabelf hrung ae nennen 12 Schlo ausf hr
31. ungen 2 cee eee 13 Beschl ge un nennen 14 Technische Daten 8 8 anes ees 15 Zum elektrischen Anschlu ae eae eee 15 Anschlu plan Dens e Arr HEAL ernennen naar 16 Ma und Einbauzeichnungen aes ss nennen 33 MaBzeichnung Modell 809 nennen 34 Einbauzeichnung HolZ er aA REELS LEE 35 Einbauzeichnung Metall eee 36 SchlieBbleche u a 4 enden sn 37 Anschlu raum Abdeckung und Zugentlastung Dr ckernu geteilt Steuerfalle Zylinder Durchbr che f r aussparung Beschlagschrauben Abbildung unverbindlich Technische nderungen vorbehalten Funktion und Bedienung Zur Funktion Das effeff Sicherheitsscho 809 ist eine v llig neuartige Kombination verschiedener Schlo funktionen Es bietet zun chst die blichen Funktionen eines normalen Riegel Fallen Schlosses mit Wechsel Dar ber hinaus vereinigt es in sich die Funktion der Selbstverriege lung mit der Panikfunktion und bietet zudem die M glichkeit einer elektrischen elektronischen Zutrittskontrolle und eine sehr differen zierte berwachung des Schlosses Selbstverriegelung bedeutet da das Schlo bei jedem Schlie en der T r automatisch den Riegel vorschlie t Die geschlossene T r ist also immer verriegelt Diese Funktion wird ausgel st durc