Home

DistoX2 User Manual - Paperless Cave Surveying

image

Contents

1. appears on the screen together with one of the following error codes 252 Temperature too high 253 Temperature too low 255 Received signal too weak 256 Received signal too high 257 Too much background light 260 Laser beam interrupted If the 2nd symbol is shown at the top of the display one of the two acceleration sensors does not work correctly The device still works with only one sensor but precision is compromised and the calibration is no longer valid if it was made with both sensors Technical Data Range Distance Azimuth Inclination Roll angle Precision Distance Angles Features Selectable Units Memory capacity Laser Type Mechanical Size Weight Protection Electrical Battery voltage 0 05 gt 100m 0 360 90 90 no steepness limit 180 180 fully tilt compensated 2mm 0 05 10m 0 5 RMS after proper calibration m ft inch grad 1000 measurements 635nm ImW class II 55 x 31 x 122mm 150g IP65 1 5 5 5V LiPo charger input 4 5 6V Power consumption Bat 4V Bat 3V original X310 Bat 3V Idle incl Bluetooth 4mA 5mA 36mA Illumination on Laser on 9mA 1lmA 43mA 88mA 110mA 120mA
2. the pairwise comparison results in a distance difference lt 5cm and a directional difference lt 3 1 7 PocketTopo uses the same measure to distinguish survey shots from splay shots A small triangle is shown a in the lower left corner of the display if the check is switched on Factory Reset Press CLR FUNC and MEM for 5 seconds to reset the device to the original state The memory is erased completely the user options are set to default values and the calibration coefficients are reset to a neutral calibration To preserve the calibration read the calibration coefficients from the device reset the device and write the coefficients back to the device Extended Measurement Information The SMART key can be used to show extended information about a measurement Repeated key presses cycle through the following parts After the last part the display returns to the standard contents Normal Measurements 1 Azimuth horizontal distance vertical distance total distance 2 Roll angle and dip angle inclination of the magnetic field 3 Magnitude of the magnetic field and the acceleration gravity 4 Raw sensor values x y z of the on board acceleration sensor 5 Raw sensor values x y z of the separate acceleration sensor 6 Raw sensor values x y z of the magnetic field sensor Calibration Measurements 1 Combined acceleration sensor values x y z 2 Magnetic field sensor values x y z 3 On bo
3. DistoX2 User Manual Leica Disto X310 based DistoX Firmware Version 2 4 2015 02 22 Introduction DistoX is an electronic surveying device for cavers It consists of a Leica Disto X310 or E7400x US version of the X310 distance meter with a built in replacement board The board extends the functionality of the Disto by a three axis electronic compass clinometer and a Bluetooth connection to enable wireless readout of the results The three axis compass allows measurements of arbitrary directions with arbitrary orientations of the device without degradation of the precision Disto Functions The Disto behaves similarly to the original X310 The display shows the Azimuth in the first the inclination in the second and the distance in the bottom line It stores up to 1000 measurements to be inspected later or transferred over the Bluetooth connection Main Functions DIST power on start Laser measure distance CLR cancel current operation switch Laser off REF il change distance reference TIMER start timer automatic measurement MEM B show memory entries SMART lt show extended measurement information see below FUNC show device information see below Restrictions The following X310 functions are not available Min Max Add Subtract Area Volume Triangle Stake out Smart horizontal Caution There is no automatic recognition of the position of the endpiece Press the REF and FUNC keys to switch b
4. ard acceleration sensor values x y z 4 Separate acceleration sensor values x y z These parts are not available when reading from memory Bluetooth Connection When Bluetooth is switched on the device is discoverable and connectable at any time It appears as DistoX nnnn where nnnn is the serial number of the device It provides a serial connection SPP named serial The device needs no pairing key If the connecting device request one it is 0000 four zeroes To read the results from the device a special program is needed PocketTopo This runs either on a PC or on a PDA To Allow the program to connect to the Disto the Bluetooth port must be selected under Menu Options Port The port is listed in the Bluetooth manager as the outgoing serial port for the device When Bluetooth is switched on a Bluetooth symbol appears at the top of the display The symbol flashes whenever another device is connected Except when a memory entry is shown the display shows the number of unsent measurements in the top right corner It is possible to switch the Laser on or off over Bluetooth and to remotely trigger a measurement The corresponding commands are in the Bluetooth menu The Disto does not automatically switch off as long as there is an active Bluetooth connection Silent Mode In Silent mode the device does not transfer measured data even if a PDA is connected The data is still saved to memory but i
5. etween rear case and endpiece reference Options and Configuration The following keys and key combinations can be used to change various options when pressed for 2 seconds MEM change distance unit REF switch to permanent front reference CLR power off MEM and SMART angle unit degrees grad MEM and FUNC silent mode on off MEM and MINUS backsight mode on off REF and MINUS beep on off REF and PLUS display illumination on off REF and FUNC back reference case endpiece CLR and SMART calibration mode on off CLR and MEM clear unsent memory CLR and FUNC Bluetooth on off CLR and MINUS locked power off SMART and MINUS triple shot check on off The distance and angle units are used for the numbers in the display only they have no influence on the stored and transmitted values Backsight Mode If the backsight mode is turned on the measurements are reported as if they were measured in the opposite direction The sign of the inclination is reversed and 180 is added to the azimuth On the display a down arrow is shown near the Laser symbol when the option is turned on and whenever a backsight measured memory value is shown Triple Shot Check If the triple shot check option is turned on the device checks for three nearly identical measurements in a row If a triple is detected the device beeps twice and shows an identical sign to the right of the measured values Three shots are considered nearly identical if
6. mmediately marked as sent The display shows three dashes in the top right corner when in Silent Mode Press MEM and FUNC for 2 seconds to switch silent mode on and off Pressing CLR and MEM for 2 seconds marks all measured data as sent without entering Silent mode Charging the Battery To charge the battery a 5V source must be connected to the charging connector in the battery compartment Any phone charger with a micro USB connector will do the job The battery indicator in the display shows the actual battery level It flashes when a charger is connected and stops flashing when the battery is fully charged Device Information The FUNC key can be used to show a sequence of information screens FUNC key in idle mode shows the first screen FUNC again navigates from one screen to the next Use the SMART key to return to the previous screen Screen Battery Shows the actual battery voltage and the battery chemistry used for the battery level indicator LP for LiPo or AL for Alkaline Press the FUNC and SMART keys for 5 seconds to change the battery chemistry Be sure to use the correct setting LI default for a built in rechargeable battery or AL for AAA primary cells Screen 2 Versions Shows the hardware and firmware version numbers and the serial number of the device Screen 3 Display Illumination Shows the display illumination level 1 10 To change the level first press the PLUS and MINUS keys for 2
7. seconds to allow editing Then press the PLUS or MINUS key to change the value To switch the illumination off completely use REF PLUS option mentioned above Screen 4 Endpiece Offset Shows the actual endpiece offset in mm 128 127 To change the level first press the PLUS and MINUS keys for 2 seconds to allow editing Then press the PLUS or MINUS key to change the value Changing the offset is useful for self made endpieces or other cases where a non standard reference is used Hints Hold the device with both hands and support them against the wall if possible To complete a measurement the DIST button may be held pressed until the measurement is done and the Laser switches off This helps making measurements without shaking the device Take care with metal objects Each kind of ferromagnetic metal near the device leads to wrong measurements This no longer only holds for the helmet but also for other objects carried at the body like SRT gear steal karabiners carbide container belts or tools which all can get to near to the device For precise measurements it is recommended to mark the rear exit point of the Laser beam picture Place this point as near as possible to the survey point Switching the display illumination off completely saves a lot of power For best performance the device should be calibrated in regular intervals Error Codes If an error occurs during a measurement the text Info

Download Pdf Manuals

image

Related Search

Related Contents

Philips PET944  Lenovo IdeaPad G780      取扱説明書~=  Akai ME80P - Midi Programmable Patch Bay  obs. - A Teleinfo  299870_BA_ Wühlmausschreck_420x297  取扱管兄日月害 保証書付き マイファン“ポータブル  Bruksanvisning User manual Bedienungsanleitung Manuel d  

Copyright © All rights reserved.