Home
User manual Toshiba heat pump control by mobile
Contents
1. Fig 4 On the wall opposite to the indoor unit Fig 5 Ona ledge opposite to the indoor unit Testing Combi Control j gt x lt To see if Combi Control can send commands to your heat pump turn off the pump and press the controller s TEST button When the connection is established Combi Control turns the pump on with its last settings and you can proceed using the controller Turning heat oump ON OFF SMS Command ON turns heat pump on SMS Command OFF turns heat pump off Commands shy _ Aep The range of heat pump temperature values Combi Control controls is 16 30 C default 20 C and the fan 6 speeds are MIN NORM MAX the default is NORM AUTO 16 MINH After selecting a mode AUTO DRY COOL HEAT T8 T10 heat pump is turned on with 20 C maximum temperature ORY ir NORM and normal fan speed if not assigned differently by the Owner or the Users see pages 24 and 29 for how to set 12 the Owner and Users j COOL MAY The pump can be assigned different temperature and fan H A T speed values with Combi Control For example the SMS COOL 19 MAX orders the pump T m 5 g to cool until 19 C and fan at maximum speed When you change a heat pump function Combi Control always Tid a0 responds with an SMS that reports its STATUS see page 39 for full STATUS report explanation Combine the pump mode room temperature and fan speed values fo
2. indicators and 2 buttons for easy setup It has also 2 infrared LEDs that transmit your commands to the heat pump LED 1 Power on switched on blinking no power working on battery off switched off LED 2 mobile phone LED on restart time SIM missing or SMS processing 1 blink 3 s interval normal status 3 blinks 3 s interval no signal from mobile phone or not connected to a mobile network blinking 500 ms interval data call session is active LED 3 IRLED blinking transmitting by IR LED 1 Power LED 2 mobile phone LED LED 3 IR LED Buttons Use a straightened paper clip or something similar to push the recessed buttons RESET button Short push turns the controller off when working on battery The controller has a battery that keeps it operational even if it s disconnected from a wall outlet To fully turn off the controller push the RESET button The 3 LED lights will blink for about a second and the controller switches off Use this button also to clear the most recent settings the Owner number will remain unchanged TEST button Short push turns the heat pump ON OFF Use the TEST button to confirm that the IR beam from the controller reaches the heat pump RESET button TEST button IR beam NB Pushing both buttons simultaneously for 3 seconds initiates the hard reset restores factory settings deletes Owner number and heat pump settings same function as with Power When
3. the power is out power OV the controller continues to work on the battery and turns off after the battery s voltage drops below 3 5V A fresh battery lasts for approximately 24 hours note that over time the battery s capacity decreases After the controller is turned off the run time will be saved To save battery life when the power is out the controller can be turned off with a short push on the RESET button SIM card NB Make sure you disable the PIN code of the SIM card you use in Combi Control NB Make sure the SIM card you use in Combi Control can access 2G network Combi Control is not compatible with SIM cards that use only 3G network A Make sure that you have previously disabled the SIM card PIN code Insert SIM card as shown into Combi Control B Plug the adapter into the socket under the Combi Control Installing Combi Control Combi Control should be mounted on the wall to the right of your heat pump s indoor unit see fig 1 with its IR transmitter pointing down This way the IR beam is reflected from the floor and reaches the heat pump s sensor most efficiently Other mounting configurations are possible too as long as IR transmission from the controller to the pump works NB Thick carpets and dark floors can distort the IR beam Make sure the IR beam reaches the pump s sensor by using the controller s Test function see page 19 Fig 3 Beneath the indoor unit
4. Combi Control Toshiba heat pump control by mobile phone User manual Combi Control Quick start guide Suitable for everybody Contents Quick start guide Suitable for everybody What Combi Control does Indicator lights Buttons Power SIM card Installing Combi Control Testing Combi Control Turning heat pump ON OFF Commands User levels Owner setup Owner number reset 10 12 12 14 19 20 22 24 26 27 Contents Advanced guide For the brave Setup reset User setup Multiple commands Heat pump model setup Alarm messages Error messages Report messages Combi Control command sheets Get in touch with us 30 31 32 34 36 39 40 44 46 What Combi Control does Combi Control is a heat pump controller you operate with a mobile phone It is compatible with most popular Toshiba heat pumps and all mobile phones see CombiControl eu for the complete list The easiest way to use Combi Control is with a Smartphone using the Combi Control app downloadable from the Android Market for Android phones or App Store for iPhone It can also be controlled with regular mobile phone text messages SMS Combi Control allows you to have long distance control over the mode of the pump room temperature and fan speed settings Combi Control can also inform you about low room temperature power failures and heat pump service intervals 6 Indicator lights The controller has 3 LED
5. Owner rights all numbers can assign themselves as owners and no alarm messages will be sent When the Owner has not set User numbers all numbers have User rights Should you suspect Combi Control could be controlled from unapproved numbers we recommend you set the Owner and User numbers Owner number reset Once set Owner number can be reset via mobile phone only by the Owner himself or by performing a hard reset by pushing both controller hidden buttons simultaneously for 3 seconds hard reset can also be used when a wrong Owner number is entered by mistake 27 Combi Control Advanced setup For the brave setup reset For setup reset send the SMS 90 to the controller Combi Control responds with SETUP report Owner All Users All Pump All Ring 2 2 2 Param 5 24 180 This means Owner is not specified all users can send commands the pump model is not specified call commands are set to default LOW TEMPERATURE message will be sent when room temperature drops below 5 C NO POWER message blackout is in 24 hours and the SERVICE alarm message interval is 180 days Setup SMS command you Response SMS Controller function you activate send Setup reset Owner deleted a SETUP and controller restart User setup To set User numbers start your command SMS with 91 followed by the mobile phone number of the User For example 91 495012345 or 915012345 to
6. V 4 20V Room xxC Room temperature in Celsius degrees GSM sq cell GSM signal strength 0 31 99 and GSM area info 1 local network 5 roaming Life mm dd Controller run time months days Owner number Owner mobile phone number SETUP report explanation SMS format Explanation Owner number All Owner number or All if not defined User1 and User2 number or All if not Users number1 number2 All detned Pump pump manufacturer s and Te en pump mogel model name lee ALL Ring x x1 x2 Ring codes Owner User1 User2 Parameters 971 low temperature Param x1 x2 x3 972 no power 973 service Heat pump ON OFF Heat pump model setup Setup command SMS Heat pump model and series T8 Command SMS Heat pump function you send ON Pump ON 950 All pump models T8 OFF Pump OFF 952 Toshiba T8 Restart and Owner number entry 9521 Toshiba Daiseikai 3 T8 Command SMS Controller function 9522 Toshiba Daiseikai 5 T8 d Setup reset Owner deleted 9523 Toshiba Daiseikai 6 T8 and controller restart Commands Command SMS Heat pump function AUTO AUTO 20 C fan NORM DRY DRY 20 C fan NORM COOL COOL 20 C fan NORM HEAT HEAT 20 C fan NORM T8 T8 mode Get in touch with us Combi Control
7. e of spaces between commands Error userrights text SMS will be sent if the user had no rights for that command Error pump command text SMS means the operation T8 is not available for the specified pump When Combi Control fails to send an SMS it will retry after 1 minute Report messages You can send report requests to Combi Control about your heat pump status controller status and the setup of the controller Report messages are sent only to the sender of the request SMS SMS command Response SMS example command function you send Pump status STATUS request Pump ON Mode HEAT Fan MAX Pump STATUS report explanation Pump STATUS report Response SMS example SMS Format Pump ON OFF NO POWER Pump ON OFF NO POWER Mode AUTO DRY COOL HEAT T8 T10 Pump mode Fan AUTO MIN NORM MAX Fan speed Temp xxC Pump temperature Room xxC Room temperature antrais Ver 1 01b05 Pump Toshiba ON Power ON VERSION orl jsueanee 4 37V Room 19C GSM 14 1 Life 00 05 mest Owner 49550111111 Owner 49550111111 Users All Pump Toshiba SETUP Setup request ON OFF NO POWER Ring 2 2 2 Param 5 24 180 Controller VERSION report explanation SMS format Explanation Ver version number Combi Control firmware version Pump type ON OFF Pump status type and ON OFF Power ON OFF x xxV Voltage 5V input and battery voltage 3 50
8. enter User1 number where 5012345 is the cell phone number of User1 and 49 is the country code User numbers Owner User1 User2 can be international with the symbol and country code or local The length of the number must be between 3 16 symbols counts as one symbol Multiple commands can be combined into one SMS When a User has been set Combi Control responds with a SETUP report message Setup SMS command you send Controller function you activate 91xx User1 number entry to delete 910 92xx User2 number entry to delete 920 93xx Owner number entry to delete 930 xx marks the place of mobile phone number Multiple commands If you want to set up several parameters with one SMS separate commands with one of the following space comma semicolon For example the SMS 91 49550111111 92 49550222222 9522 9720 sets the User1 and User2 numbers specifies the heat pump model as Toshiba Daiseikai 5 and determines that NO POWER message will not be sent in case of a power failure When a command in the multi setup is incorrect the Owner will receive an error message All the correct commands that precede the error command in the multi setup command will be activated Multi setup sender will always receive SETUP report SMS from Combi Control to confirm that all commands arrived to the controller There can be spaces before and after a command but not inside a command as th
9. is will interfere with the code Heat pump model setup The pump can be chosen on 3 levels of precision 1 The precise name of the pump the manufacturer and the model This is recommended for the most efficient operation 2 Pump manufacturer If you only choose the pump manufacturer functions T8 will not be checked and the command will be sent even if the pump does not have T8 mode If the exact pump model is not listed on our webpage or in this manual Combi Control may or may not work with the heat pump for which the Combi Control manufacturer will not be held responsible 3 All pump models If you choose All pump models SMS 950 then all supported brands IR commands will be sent to the pump and Combi Control can be used without choosing the pump more precisely Setup SMS command Heat pump model and series T8 you send 950 All pump models T8 952 Toshiba T8 9521 Toshiba Daiseikai 3 T8 9522 Toshiba Daiseikai 5 T8 9523 Toshiba Daiseikai 6 T8 T8 is a heat pump function that keeps the room temperature from dropping below 8 C respectively Alarm messages setup The Owner can change the default values of the conditions on which alarm messages are sent For example SMS 9713 lowers the room temperature value at which LOW TEMPERATURE SMS is sent from the default 5 C to 3 C Setup SMS Response Combi Control function you activate Default command you SMS format values send tempe
10. r a home atmosphere you like the best 22 User levels The amount of control Combi Control users have over the device and the amount of information they receive from the device can be set on a 3 level scale 1 The Owner can send commands report queries setup commands and receive Combi Control report messages and alarm messages 2 The Users can send commands and report queries to Combi Control but cannot send Setup commands 3 The Alll level users can make report queries about the status of the controller 24 Owner setup Setup can only be performed by the Owner When no Owner has been previously set Owner number can be sent from any mobile phone number There are 2 ways to do this The to be Owner sends the SMS 93 to the controller The SMS containing 93 followed by the mobile number of the to be Owner e g 935012345 is sent from any mobile phone The Owner number can be international with the symbol and country code or local The length of the number must be between 3 16 symbols counts as 1 symbol Successful Owner number entry Owner number change is confirmed by VERSION report SMS sent to the new Owner see page 40 for full VERSION report explanation After Owner number has been set up setup can be done from this Owner number All other numbers attempting 26 to change setup will be ignored When no Owner number has been entered all numbers have
11. rature treshold for sia eae LOW TEMPERATURE message c 92xx SETUP i NO POWER message blackout 24h in hours 93xx SETUP SERVICE message interval 180 days in days xx marks the place of the numeric value The LOW TEMPERATURE parameters 971 can be between 0 16 The NO POWER parameters 972 can be between 0 48 The SERVICE parameters 973 can be between 0 360 When you set parameter 971 to 0 e g you send a text message 9710 then the controller will not send you a LOW TEMPERATURE message When you set parameter 972 to 0 then NO POWER message will not be sent When you set parameter 973 to 0 then SERVICE message will not be sent Alarm messages Alarm messages are only sent to the Owner Combi Control alarm SMS Alarm message meaning Message blackout alarm treshold e g LOW TEMPERATURE 6 C when the limit is 7 C Room temperature is low 24h 5 C NO POWER 220V power failure Default 24h e g SERVICE 1 days Service date Default 180 days After setting a new VERSION New Owner Owner or changing Owner Error messages Error command text SMS will be sent if there was an error in your command For example an SMS cool19max receives the response Error command cool19max Note that Combi Control will only return your incorrect command without suggesting a correct one the error in the example is the absenc
Download Pdf Manuals
Related Search
Related Contents
PWM 正弦波コンバータ Dell 230S Personal Computer User Manual Philips 14PV330/07 VCR User Manual アイオンヘッドランプ取扱説明書 1- CR réunion 070303.cwk Manual de Usuario Amacén オールマイティーGO!! GM-180 Télécharger Devezeaud-Note-de-jurisprudence-1 (H23年11月号) [PDFファイル/1.32MB] Copyright © All rights reserved.
Failed to retrieve file