1. Hungarian 101 Key Japanese Windows IBM NCR Terminals Slovakia SD61 Base Station User s Guide Chapter 2 Connecting the SD61 to a Host Wand Emulation Cable Connection Connect the SD61 to a host using the wand emulation cable To connect a wand emulation cable 1 Make sure that you have the wand emulation cable P N 236 163 xxx 2 Turn off your host device 3 Connect the cable to your SD61 and host device A To host device G b Y i EM Lm 4 Turn on your host device The SD61 is successfully connected and power is on when it emits two beeps and two light flashes Wand Emulation Configuration Bar Codes Configure your SD61 wand emulation parameters if necessary This section contains bar codes for a basic setup To configure additional wand emulation parameters see EasySet 5 6 2 0 or later You must have at least one Intermec Bluetooth scanner connected to the SD61 Base Station to scan the configuration bar codes in this section See How to Connect an Intermec Scanner to the SD61 on page 2 for more info SD61 Base Station User s Guide 13 Chapter 2 Connecting the SD61 to a Host Default Logic Level During Transmission Logic level during transmission bar 0 space 1 Logic level during transmission bar 1 space 0 Removing a Cable Remove the cable by pressing the release button located on the SD61 Base Sta
2. Select your product 5 Select Communication gt Select Communication Interface The Communication Interface dialog box appears Select the communication interface that you are using for your SD61 and click OK EasySet connects to your SD61 and retrieves the current configuration of the base station and connected scanner These configurations are indicated with blue text Open the folders to find the configuration commands for the scanner Double click each command to send it to the scanner via che SD61 Base Station SD61 Base Station User s Guide Chapter 3 Configuring the SD61 and Connected Scanner s Offline Setup with EasySet It is not necessary for the scanner to be connected to the base station for offline setup To configure a scanner offline by scanning bar codes 1 Start EasySet The first time you start EasySet the Select product dialog box appears Ifthe Select product dialog box does not appear choose Product gt Select 2 Select your product 3 Open the folders to find the configuration commands needed Double click each command or click the green arrow to the right of the product icon to send each command to the setup sheet 4 Print out the setup sheet and scan the commands documentation for your specific product Note For full details on setting up your scanner refer to the SD61 Base Station User s Guide 19 Chapter 3 Configuring the SD61 and Connected Scanner s 20 SD61
3. Wand Emulation Temperature and Environmental Specifications Operating temperature Storage temperature Relative humidity 96 hrs Drop Shock Vibrations Bluetooth Radio Radio type Frequency Communication range Bluetooth connections 32 20 C 4 F to 60 C 140 F 40 C 40 F to 70 C 158 F 95 45 C 113 F non condensing 26 drops from 1 2 m 3 9 ft on concrete 8G from 10Hz to 500Hz 2hr axis 3 axis Bluetooth Class 1 version 2 0 2400 2483 5 MHz 100 meters 328 feet Maximum 7 scanner connections SD61 Base Station User s Guide Appendix A Specifications and Command Set SD61 Command Set The following tables list the commands supported by the SD61 Base Station and their default values where applicable For detailed command descriptions see the EasySet online help The latest version of EasySet is available at no charge from the Intermec website at www intermec come EasySet The commands are grouped by function and reflect the organization of EasySet Reset All Parameters Command Reset factory defaults RS 232 Parameters Command Baud rate RTS CTS hardware protocol Data bits Parity Stop bits ENO ENO character ACK ACK character NACK NACK character XON XOFF software protocol LRC Longitudinal Redundancy Check Hardware software protocols timeout ms SD61 Base Station User s Guide Default Value Default Value 19200 D
4. BeforeVou Begin tek dat tgs iden EE st eet ep Edi t viii Safety Informations scc 24 40h beh steeds EEEE BAe hhc V PER de ADAE EDS viii Global Services and SUPPONE oas orrira EIEE DECAAN EErEE viii Warranty Information aE a I AAEE ee viii Web Supports Le ese esee i WEE C TA GA bes dro ix Telephone S ppott chop cbe eyed encode d s po RUP deda bs ix Service Location SUPpOrt 0 cece eee ees 1X Who Should Read This Manual seeeeee n x Related Documents 344 5 soe dick Occ RM EID SERE ate des x Patent Information redisian eunes ccc ec cee en x 1 Learning About the SD61 cece 1 Introducing the SD61 Base SANON piere einan nanna IAIN EN EEE e 2 Howto TurmOnthesD6l izleeeniveet 6 dlane Gu k a Mea bbe enn Ae egae Ex 2 How to Connect an Intermec Scanner to the SD61 ccc ccc ee cee 2 Understanding the LERE o sar EET NE EEANN SR AR EERE ETEN EN 3 Understanding the Beeps 2 1 terere AS QM ee E EEA 4 2 Connecting the SD61 to a Host 5 RS 232 Cable Connection 3 05 2h kee ts Ged S ee DIS 6 RS 232 Configuration Bar Codes 44 4 4444 7 Baud Rate 55 meo etui M oh dole o Za aa aan te RAS ok IR Naa eeeh 7 Data Bits co u kv a Seek a oh e aka adobe a Oe es 8 Panty 2enier eue baln Sawa V PRI AEA x porna NODE Aura d ed as 8 Stop BItSx ri Gude rete A S eR RESQUE e epi eid tube 8 USB Keyboard Wedge Y Cable Connections 0 0 0 ccc cee cece eee eens 9 USB Cable
5. Reading the Reset Configuration Bar Code To reset the SD61 factory defaults by reading the configuration bar code you must have at least one scanner connected to the base station Reset Factory Defaults Using the Push Button to Reset the SD61 If you do not have at least one scanner connected to the SD61 you can reset the factory defaults by pressing the push button located inside the front cover of the SD61 RJ45 Connector Push Button M Push button location To reset factory defaults with the push button 1 Push the button and hold it down for 20 seconds The blue Intermec Ready to Work light flashes quickly then slowly and then stays on 2 Release the push button If there are scanners that are connected che SD61 disconnects the scanners resets the factory defaults and then restarts Scanners that were connected will try to reestablish a Bluetooth connection with the SD61 after it restarts Note You can also reset the SD61 factory defaults by using online leg setup with EasySet See the EasySet software for more information SD61 Base Station User s Guide 25 Chapter 4 Troubleshooting and Maintaining the SD61 Maintaining the SD61 To keep your SD61 in good working order you may need to upgrade the SD61 firmware Upgrading the SD61 When you upgrade your SD61 the current settings are erased and replaced with the default settings
6. To connect with an RS 232 cable 1 Make sure you have the powered RS 232 cable P N 236 161 xxx 2 Turn on your host device 3 Connect the cable to your SD61 and host device AC power supply To host device 4 Connect the power supply P N 851 089 105 to the RS 232 cable and an AC power outlet The SD61 is successfully connected and power is on when it emits two beeps and two light flashes 5 If necessary configure your SD61 serial parameters to match the host device The default serial parameters for the SD61 are Baud Rate 19200 Data Bits 8 Parity none Stop Bits 1 6 SD61 Base Station User s Guide Chapter 2 Connecting the SD61 to a Host RS 232 Configuration Bar Codes Configure your SD61 serial parameters to match the host if necessary This section contains bar codes for basic serial parameters To configure additional serial parameters see EasySet 5 6 2 0 or later You must have at least one Intermec Bluetooth scanner connected to the SD61 Base Station to scan the configuration bar codes in this section See How to Connect an Intermec Scanner to the SD61 on page 2 for more info Note By default RTS CTS hardware protocol is disabled To enable K this parameter use EasySet 5 6 2 0 or later RTS CTS hardware protocol operates only in one direction The SD61 requests permission from the host to transmit and monitors host transmissions Default Baud Rate 19200 38400 57600 11520
7. Connection c is ee A ee oe ee de Se elon bs GRR eee 9 Keyboard Wedge Y Cable Connection cece cece eee 9 USB Keyboard Wedge Y Cable Configuration Bar Codes 10 International Keyboard 4440000000006 11 Wand Emulation Cable Connection 4 lt 13 Wand Emulation Configuration Bar Codes 44 4 13 Logic Level During Transmission esses eee eee 14 SD61 Base Station User s Guide vi Contents Removing a Cable e ra ze zed tes ede pete Elo dy ome el lex E ege ehe es 14 3 Configuring the SD61 and Connected Scanner s 15 Using EasySet Configuration Software csse eee 16 How to Configur the SDG sic cerebro peru e EE HEY DRE eqq 16 Online Setup with Easy Sen oniyi breaka Ern EAA ENEE A kk 16 Otflin Setup with EasyS t c costo PE ps E OAA EA ou ob ae 17 How to Configure a Connected Scanner rerien etei ccc cece eee 18 Online Setup with EasySet vere ence teer E EU NR SP PR te Dad 18 Offline Setup with EasySet cece eee nee 19 4 Troubleshooting and Maintaining the SD61 21 Troubleshootine the SD6 hory ceret s Goes oven ts GEA EAE tege EO EUER Os 22 Calling Product Support ois cess SERRA DE RETIRER ee ER ES 22 Problems and Possible Solutions lesse 24 Resetting Factoty Defaults c scs ebcee AE EE Pa piace ed HARRI RES EENES 24 Reading the
8. Reset Configuration Bar Code 25 Using the Push Button to Reset the SD61 25 Maintaining the SD61 5i Le te du en XR RR E ete ai et ned Heda 26 Upgrading the SD61 22 oce ny db patn Y EE eU RES 26 A Specifications and Command Set 31 Specifications 34 abo epdeeset d ticked Voda p n o a Seley tee Mee eRe sys 32 SD61 Corimand Set 5 koa cae deck ass erac tv oa teu b es ek o o Ur 33 vii SD61 Base Station User s Guide Before You Begin Before You Begin This section provides you with safety information technical support information and sources for additional product information Safety Information Your safety is extremely important Read and follow all warnings and cautions in this document before handling and operating Intermec eguipment You can be seriously injured and eguipment and data can be damaged if you do not follow the safety warnings and cautions This section explains how to identify and understand dangers warnings cautions and notes that are in this document You may also see icons that tell you when to follow ESD procedures and when to take special precautions for handling optical parts condition or statement that must be strictly observed to avoid A warning alerts you of an operating procedure practice death or serious injury to the persons working on the equipment Warning A caution alerts you to an operating procedur
9. Turn off your host device 3 Connect the cable to your SD61 and host devices AC power supply To host devices 4 Connect the power supply if necessary to the keyboard wedge Y cable and an AC power outlet 5 Turn on your host device The SD61 is successfully connected and power is on when it emits two beeps and two light flashes 6 If necessary configure your SD61 for an International keyboard USB Keyboard Wedge Y Cable Configuration Bar Codes 10 Configure your USB Keyboard Wedge Y cable for an international keyboard if necessary This section contains bar codes for a basic setup To configure additional parameters see EasySet 5 6 2 0 or later You must have at least one Intermec Bluetooth scanner connected to the SD61 Base Station to scan the configuration bar codes in this section See How to Connect an Intermec Scanner to the SD61 on page 2 for more info SD61 Base Station User s Guide Default mn Keyboard North America French Canadian Windows 95 98 German Windows Italian Windows UK English Windows SD61 Base Station User s Guide Chapter 2 Connecting the SD61 to a Host French Windows French Canadian Windows XP 2000 Spanish Windows Swedish Windows 11 Chapter 2 Connecting the SD61 to a Host 12 Brazilian Portuguese Windows Czech Republic
10. see Connecting the SD61 to a Host on page 5 SD61 Base Station User s Guide Chapter 1 Learning About the SD61 2 Wich an Intermec Bluetooth scanner scan the association bar code on the top of the SD61 Base Station The scanner beeps once the green status light flashes once and the blue Intermec Ready to Work indicator starts blinking When the scanner connects to the base station it emits a series of beeps from low to high The blue Intermec Ready to Work indicator turns on and stays on for both the scanner and base station 3 To add more scanners repeat steps 1 and 2 Note Ifyou cannot read the association bar code located on the top log of the SD61 Base Station see Problems and Possible Solutions on page 24 If the Bluetooth connection is lost out of range scanner battery too low etc the scanner and base station will automatically try to reconnect once the problem is resolved back in to range recharge scanner battery etc Understanding the Light The SD61 has a blue Intermec Ready to Work light located on top of the base station This light is used to indicate the status of the Bluetooth connection Blue Intermec Ready to Work Indicator Description Light State What It Means Two flashes then off Power up SD61 Base Station User s Guide 3 Chapter 1 Learning About the SD61 Blue Intermec Ready to Work Indicator Description Light State On One blink Off What It Means A Blue
11. 0 SD61 Base Station User s Guide 7 Chapter 2 Connecting the SD61 to a Host Data Bits 7 dedi None Even xd Bits 8 SD61 Base Station User s Guide Chapter 2 Connecting the SD61 to a Host USB Keyboard Wedge Y Cable Connections This section provides information on cable connections for both USB cables and Keyboard Wedge Y cables Each cable connection is explained separately however the configuration bar codes provided at the end of this section apply to both types of cables USB Cable Connection Connect the SD61 to a host using a USB cable To connect with a USB cable 1 Make sure that you have the USB cable P N 236 164 xxx 2 Turn on your host device 3 Connect the cable to your SD61 and host device To host device k rd e The SD61 is successfully connected and power is on when it emits two beeps and two light flashes 4 If necessary configure your SD61 for an International keyboard see USB Keyboard Wedge Y Cable Configuration Bar Codes on page 10 Keyboard Wedge Y Cable Connection Connect the SD61 to a host using the keyboard wedge Y cable Depending on your host this cable may need an external Intermec power supply SD61 Base Station User s Guide g Chapter 2 Connecting the SD61 to a Host To connect with a keyboard wedge Y cable 1 Make sure that you have the keyboard wedge cable Y cable P N 236 204 xxx and optional power supply P N 851 089 105 2
12. After upgrading you will have to reestablish Bluetooth communications between the scanner s and the SD61 Base Station To upgrade the SD61 firmware you need these items e a powered RS 232 cable and external power supply see RS 232 Cable Connection on page 6 e aPC running Microsoft Windows XP with SP2 or Microsoft Windows 2000 e EasySet version 5 6 2 0 or later thefirmware upgrade file bin To upgrade the SD61 firmware 1 Download the latest SD61 firmware file bin from the Intermec web site at www intermec com a Goto Support gt Downloads b Inthe drop down lists used to locate a product choose Bar Code Scanners Rugged SD61 Base Station c Click the link to download the firmware upgrade file and save it to your PC 2 Connect your SD61 toa host PC with the RS 232 cable see RS 232 Cable Connection on page 6 3 Start EasySet version 5 6 2 0 or later 26 SD61 Base Station User s Guide Chapter 4 Troubleshooting and Maintaining the SD61 4 Initialize firmware download mode by doing one of the following e scanning the firmware upgrade bar code with a connected Firmware upgrade with an RS 232 cable scanner Using the push button Disconnect the power supply SD61 is off hold the push button down while reconnecting the power supply to turn the SD61 on Release the push button RJ45 C
13. Base Station User s Guide Troubleshooting and Maintaining the SD61 Use this chapter to solve problems you may have while using the SD61 This chapter contains these topics Troubleshooting the SD61 Maintaining the SD61 21 Chapter 4 Troubleshooting and Maintaining the SD61 Troubleshooting the SD61 If you have problems using the SD61 use this chapter to find a possible solution Calling Product Support To talk to an Intermec Product Support representative Inthe U S A and Canada call 1 800 755 5505 Outside the U S A and Canada contact your local Intermec representative For help go to www intermec com gt About Us gt Contact Us Before you call Intermec Product Support make sure you have the following information e SD61 firmware version e SD61 Bluetooth address To get the firmware version and Bluetooth address 1 You must have at least one Intermec Bluetooth scanner connected to the SD61 Base Station 2 Runan application that can accept bar code information from the SD61 Base Station Ifyou are using a USB or Keyboard wedge cable use Microsoft Notepad Ifyou are using an RS 232 cable use the EasySet ISCP Terminal Window For help see the EasySet software 3 Scan one of these bar codes Get Firmware Version 22 SD61 Base Station User s Guide Chapter 4 Troubleshooting and Maintaining the SD61 Get Bluetooth address When you scan the Get Firmware Ve
14. S D 61 Base Station Intermec Intermec Technologies Corporation Worldwide Headguarters 6001 36th Ave W Everett WA 98203 U S A www intermec com The information contained herein is provided solely for the purpose of allowing customers to operate and service Intermec manufactured equipment and is not to be released reproduced or used for any other purpose without written permission of Intermec Technologies Corporation Information and specifications contained in this document are subject to change without prior notice and do not represent a commitment on the part of Intermec Technologies Corporation 2009 by Intermec Technologies Corporation All rights reserved The word Intermec the Intermec logo Norand ArciTech Beverage Routebook CrossBar dcBrowser Duratherm EasyADC EasyCoder EasySet Fingerprint i gistics INCA under license Intellitag Intellitag Gen2 JANUS LabelShop MobileLAN Picolink Ready to Work RoutePower Sabre ScanPlus ShopScan Smart Mobile Computing SmartSystems TE 2000 Trakker Antares and Vista Powered are either trademarks or registered trademarks of Intermec Technologies Corporation There are U S and foreign patents as well as U S and foreign patents pending Bluetooth is a trademark of Bluetooth SIG Inc U S A ii SD61 Base Station User s Guide iii SD61 Base Station User s Guide SD61 Base Station User s Guide SD61 Base Station User s Guide Contents Contents
15. act your local Intermec representative To search for your local representative from the Intermec web site click About Us gt Contact Us Service Location Support For the most current listing of service locations go to www intermec com and click Support gt Returns and Repairs gt Repair Locations For technical support in South Korea use the after service locations listed below AWOO Systems 102 1304 SK Ventium 522 Dangjung dong Gunpo si Gyeonggi do Korea South 435 776 Contact Mr Sinbum Kang Telephone 82 31 436 1191 E mail mjyun awoo co kr SD61 Base Station User s Guide Before You Begin IN Information System PTD LTD 6th Floor Daegu Venture Center Bldg 95 Shinchun 3 Dong Donggu Daegu City Korea E mail jmyou idif co kr or korlim gw idif co kr Who Should Read This Manual This guide is for the person who is responsible for installing configuring and maintaining the SD61 Base Station This document provides you with information about the features of the SD61 and how to install configure operate maintain and troubleshoot it Related Documents The Intermec web site at www intermec com contains our documents as PDF files that you can download for free To download documents 1 Visit the Intermec web site at www intermec com 2 Click Support gt Manuals 3 In the Select a Product field choose the product whose documentation you want to download To order printed versions of the In
16. ceiving power Make sure you are using the correct cable and power supply if necessary When the SD61 is powered up it emits two beeps and two light flashes Restart the SD61 by disconnecting and reconnecting the power supply You can also reset the factory defaults of both the SD61 and your scanner to reset your scanner see your scanner s documentation Make sure the cables are connected between the SD61 and the host Make sure the SD61 is configured correctly for the interface you are using For help see Connecting the SD61 to a Host on page 5 The data may still be in the process of being sent to the host Data transmission may be slow if there is interference with Bluetooth communications or if the scanner is too far from the SD61 Base Station Check the blue Ready to Work light to be sure that the scanner is connected to the SD61 Use the EasySet software to create a new association bar code see EasySet for help You need the SD61 Bluetooth address to create this bar code see To get the firmware version and Bluetooth address on page 22 If your SD61 does not transmit data or connect to a scanner you can reset the factory defaults There are two ways to reset the factory defaults of your SD61 Base Station e By reading the reset factory defaults configuration bar code e By using the push button on the SD61 24 SD61 Base Station User s Guide Chapter 4 Troubleshooting and Maintaining the SD61
17. e practice condition or statement that must be strictly observed to prevent equipment damage or destruction or corruption or loss of data aution special instructions for handling a particular condition or set of Note Notes either provide extra information about a topic or contain circumstances Global Services and Support Warranty Information To understand the warranty for your Intermec product visit the Intermec web site at www intermec com and click Support gt Returns and Repairs gt Warranty SD61 Base Station User s Guide viii Before You Begin Disclaimer of warranties The sample code included in this document is presented for reference only The code does not necessarily represent complete tested programs The code is provided as is with all faults All warranties are expressly disclaimed including the implied warranties of merchantability and fitness for a particular purpose Web Support Visit the Intermec web site at www intermec com to download our current manuals in PDF To order printed versions of the Intermec manuals contact your local Intermec representative or distributor Visit the Intermec technical knowledge base Knowledge Central at www intermec com and click Support gt Knowledge Central to review technical information or to request technical support for your Intermec product Telephone Support In the U S A and Canada call 1 800 755 5505 Outside the U S A and Canada cont
18. he firmware download is complete the Operation successful message appears Zz Download progress In xl Driver Product detection done 59ax Driver selection C Program Files Intermec Winflash 44 dra Driver download 5984 Flash Driver Version 1 06 Product identification EV12 AM2SLV400B Product firmware version A41P115_ Flash read Flash erase done Flash write done New firmware version A41P115 Driver remove done Download cable reset Operation successful 100 Start download 11 Click Finish You have successfully upgraded your SD61 firmware firmware download procedure and use the push button only step 4 Note If the firmware download is not successful you must restart the to initialize download mode The push button is the only way to recover the base station SD61 Base Station User s Guide 29 Chapter 4 Troubleshooting and Maintaining the SD61 30 SD61 Base Station User s Guide Specifications and Command Set This appendix contains the technical specification and the supported command set with the default values 31 Appendix A Specifications and Command Set Specifications Physical Dimensions Height Width Depth Weight Electrical Specifications Operating voltage Operating current Interface 36 mm 1 4 in 102 mm 4 0 in 115 mm 4 5 in 150g nominal 5V 10 75mA RS 232 USB generic HID and Keyboard HID Keyboard Wedge
19. isabled 8 bits None 1 Disabled lt ENQ gt 0x05 Disabled lt ACK gt 0x06 Disabled lt NAK gt 0x15 Disabled Disabled 1000 33 Appendix A Specifications and Command Set USB Parameters Command USB cable mode International Keyboard Parameters Command International keyboard Wand Emulation Parameters Command Logical level during transmission Logical level outside transmission Pulse duration ISCP Parameters Command ISCP protocol Data format Start up event Bar code data format Data Transmission Parameters Command DBP transmission format Inter character delay ms Inter message delay ms Default Value Generic HID Default Value North America Default Value Bar 0 Space 1 Ouiet zone 1 30 Default Value Disabled Raw data Disabled BCD BCDEX2 Default Value Code 128 0 0 SD61 Base Station User s Guide Appendix A Specifications and Command Set Data Transmission Parameters continued Command Default Value Preamble None Postamble lt CR gt lt LF gt Beeps LED Indicator Command Default Value Power up beeps Enabled Good read beep number 1 beep Good read events timing Before transmission Error beep Enabled Setup beep Enabled Beep volume Medium Beep frequency 2090 Hz Good read beep duration ms 80 ms Green LED duration ms 80 ms Configuration Modes and Utilities Command Default Value Get firmware version Flash memory upg
20. m EasySet 1 Connect the SD61 to a host PC using an RS 232 or USB generic HID connection and set connection parameters Start EasySet The first time you start EasySet the Select product dialog box appears If the Select product dialog box does not appear choose Product gt Select 3 Select your product Select Communication gt Select Communication Interface The Communication Interface dialog box appears Select the communication interface that you are using for your SD61 and click OK EasySet connects to your SD61 and retrieves the current configuration These configurations are indicated with a blue check mark or blue text SD61 Base Station User s Guide Chapter 3 Configuring the SD61 and Connected Scanner s 6 Open the folders to find the configuration commands needed Double click each command to send it to the SD61 Note The SD61 does not beep when you send configuration O commands online from EasySet Offline Setup with EasySet To perform offline setup you must have at least one Intermec Bluetooth scanner connected to the SD61 Base Station see How to Connect an Intermec Scanner to the SD61 on page 2 The scanner reads the configuration bar code and sends it to the base station to be processed To configure the SD61 offline by scanning bar codes 1 Start EasySet The first time you start EasySet the Select product dialog box appears If the Select product dialog box does not appear choo
21. onnector Push Button ne TM n 00000000 5 5 From the Tools menu select Upgrade product firmware If WinFlash is not already installed you will be asked to install it Click Yes and following the installation instructions After installing Winflash start WinFlash from the Tools menu select Upgrade product firmware SD61 Base Station User s Guide 27 Chapter 4 Troubleshooting and Maintaining the SD61 6 Use Browse to browse to the location of the firmware upgrade file bin select the file and click Open zmz Product EV12 amp Cable type Demo board Standard R5232 cable 3 414032 00 Select or enter the filename of the firmware to download into the product Browse Get Firmware Version Only 7 Click Next The Com port selection window appears Com port selection m In xi Product EV12 Cable type Demo board Standard RS232 cable 3 414032 00 a Filename C Temp 441P115_ bin Select the communication port you are connected to Select the speed comi v C 9600 19200 C 38400 57600 C 115200 Display help lt Back Cancel Help 8 Select the COM port the SD61 is connected to select a baud rate and deselect the Display help check box 28 SD61 Base Station User s Guide Chapter 4 Troubleshooting and Maintaining the SD61 9 Click Next The Download progress window appears 10 Click Start download When t
22. rade Get Bluetooth device address Get sub system version SD61 Base Station User s Guide 35 Appendix A Specifications and Command Set 36 SD61 Base Station User s Guide Intermec Worldwide Headquarters 6001 36th Avenue West Everett Washington 98203 U S A tel 425 348 2600 fax 425 355 9551 www intermec com 2009 Intermec Technologies Corporation All rights reserved SD61 Base Station User s Guide P N 3 231049 11
23. rsion configuration bar code in addtion to displaying the firmware version on the screen the SD61 Base Station emits a series of beeps The beeps indicate the 3 digit firmware version The beeps are counted as follows e series of beeps a number 1 beep 0 2 beeps 1 etc one long beep space between digits Example Firmware version 104 1 Space 0 Space 4 2 beeps 1 long beep 1 beep 1 long beep 5 beeps Note If you do not have at least one Intermec Bluetooth scanner O connected to the SD61 you can get the firmware version and Bluetooth address by using EasySet online setup only available with an RS 232 and USB generic HID connections For more information see the EasySet software SD61 Base Station User s Guide 23 Chapter 4 Troubleshooting and Maintaining the SD61 Problems and Possible Solutions Use this section to find possible solutions to problems you may have Problem The SD61 does not turn on You cannot establish a Bluetooth connection the blue Intermec Ready to Work indicator is not on The SD61 cannot communicate with the host You scan a data bar code but the SD61 does not beep and the light does not flash The association bar code located on the SD61 is damaged or missing and cannot be read by the scanner Resetting Factory Defaults Possible Solution The SD61 is not re
24. se Product gt Select 2 Select your product 3 Open the folders to find the configuration commands needed Double click each command or click the green arrow to the right of the product icon to send each command to the setup sheet 4 Print out the setup sheet and scan the commands SD61 Base Station User s Guide 17 Chapter 3 Configuring the SD61 and Connected Scanner s How to Configure a Connected Scanner You can also configure your Intermec Bluetooth scanner online via the SD61 Base Station or offline with EasySet Online Setup with EasySet Send configuration commands directly to your scanner via the SD61 Base Station Online setup via the base station is only available if your scanner has established a Bluetooth connection with the base station 18 Note If you have several scanners connected the configuration commands sent online via the base station are sent to the last scanner chat communicated with the base station To configure a scanner online by sending commands from EasySet 1 Connect the SD61 to a host PC using an RS 232 or USB generic HID connection and set connection parameters Establish a Bluetooth connection between the scanner and the SD61 Base Station see How to Connect an Intermec Scanner to the SD61 on page 2 Start EasySet The first time you start EasySet the Select product dialog box appears If the Select product dialog box does not appear choose Product gt Select
25. termec manuals contact your local Intermec representative or distributor Patent Information This product is covered by one or more patents There may be other U S and foreign patents pending SD61 Base Station User s Guide x Before You Begin xi SD61 Base Station User s Guide Learning About the SD61 Use this chapter to familiarize yourself with the SD61 Base Station This chapter covers these topics Introducing the SD61 Base Station How to Turn On the SD61 How to Connect an Intermec Scanner to the SD61 Understanding the Light Understanding the Beeps Chapter 1 Learning About the SD61 Introducing the SD61 Base Station The SD61 Base Station is used to connect up to seven Intermec cordless Bluetooth scanners to a non Bluetooth host device Data is transmitted from the scanner to the host via the SD61 Base Station Intermec Ready to Work light RJ45 Connector SD61 Base Station How to Turn On the SD61 The SD61 is powered through the cable connected to a host device Depending on which cable you are using power comes from either the host device or the external power supply See Connecting the SD61 to a Host on page 5 for details on Connections How to Connect an Intermec Scanner to the SD61 You can connect up to seven Intermec Bluetooth scanners to the SD61 Base Station To connect up to 7 scanners 1 Connect the SD61 base station to a host device using the correct cable for your interface
26. tion under the RJ45 Connector Press the button firmly When the button is pushed correctly the cable is easily removed Release button Removing a Cable Press the release button firmly and gently pull out the cable 14 SD61 Base Station User s Guide Configuring the SD61 and Connected Scanner s This chapter provides information on how to configure the SD61 Base Station and the connected scanner s using the EasySet configuration application The chapter includes Using EasySet Configuration Software How to Configure the SD61 How to Configure a Connected Scanner 15 Chapter 3 Configuring the SD61 and Connected Scanner s Using EasySet Configuration Software EasySet is an Intermec configuration application that provides you with two ways to configure the SD61 Base Station and scanner s Using online setup to send configuration commands from EasySet directly to the product Using offline setup to send configuration commands to a bar code setup sheet print the setup sheet and use a connected scanner to scan the bar codes EasySet is available on the Intermec website at www intermec com EasySet Simply download and install How to Configure the SD61 Use this section to configure the SD61 Base Station parameters Online Setup with EasySet Online setup with EasySet is only available if you are using an RS 232 or USB generic HID connection 16 To configure the SD61 online by sending commands fro
27. tooth connection has been established wich one or more scanners The SD61 is ready to receive data from the scanner s Data has been successfully transmitted to the host A Bluetooth connection has not been established Understanding the Beeps The SD61 beeps to give you audio feedback when performing some functions For example you hear a beep each time a connected scanner scans a valid bar code Beep Seguence Two beeps Single high beep Series of beeps What It Means Power up Data has been successfully transmitted to the host Indicates firmware version See To get the firmware version and Bluetooth address on page 22 necessary See EasySet version 5 6 2 0 or later for beeper configuration Note You can change the beep volume tone or turn it off if options SD61 Base Station User s Guide Connecting the SD61 to a Host The SD61 Base Station is connected to a host device using a different cable depending on the interface for your application Use this chapter to understand how to connect each type of cable and configure the SD61 to communicate with your application if necessary This chapter includes e RS 232 Cable Connection e USB Keyboard Wedge Y Cable Connections Wand Emulation Cable Connection Removing a Cable Chapter 2 Connecting the SD61 to a Host RS 232 Cable Connection Connect the SD61 to the host using the powered RS 232 cable which reguires an exernal Intermec power supply