Home

USER MANUAL - Rais

image

Contents

1. is alight IMPORTANT Safety advice When using the stove in situations where children aged and or infirm persons are pres ent a fireguard must be used to prevent accidental contact with the stove The fireguard should be manufactured in accordance with BS 8423 2002 Replaces BS 6539 21 ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 Lighting and fuelling To light the stove use alcohol briquettes or similar as well as approx 2 kg of firewood split into kindling sticks Set the air damper to the fully open position TIPS before firing up Open a door or window close to the wood burning stove If there is a storm in the stove coming from the chimney it is advisable to place a screwed up piece of newspaper between the upper baffle plate and the chimney set the paper on fire and wait until you hear a rumbling noise in the chimney This means that there definitely is a draught in the chimney and you avoid smoke in the room Light the fire and shut the door leaving the door ajar approx 10 15 mm ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 When the flames are clear after approx 5 10 min close the door Damper see adjustment of air damper After approx 10 20 min when you have a good bed of glowing embers add 2 3 pieces of wood Leave the door ajar until the fire has caught on properly close the door Damper see adjustment of air damper After appro
2. production number We therefore recommend that you note down the number in the table below The pro duction number is located on the back of the stove at the bottom Warranty Your RAIS wood burning stove comes with a 5 year warranty The warranty however does not cover heat insulating materials glass and seals Any alterations made to the stove will void the warranty RAIS A S Industrivej 20 Vangen 9900 Frederikshavn O Prod nr Distributor Date 4 ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 Specifications RAIS Rondo 92 RAIS Rondo 120 Nominel output kW 5 5 Min Max output kW 3 8 3 8 Heating areal m ca 100 E ca 100 Stove s width depth height mm 490 490 920 490 490 1200 Combustion chamber s width depth height mm 350 290 355 350 290 355 Recommended amount of wood when fuelling kg 1 5 1 5 Distributed on 2 3 logs of wood of approx 25 cm Min uptake Min draught Pascal 12 12 Weight kg 115 140 Smoke gas mass flow 9 5 4 7 4 7 Smoke gas temperature C 246 246 Intermitterent operation Fueling should be undertaken within 3 hours ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 Convection RAIS stoves are convection stoves This means that the stove s back and side panels are not over heated Convection means that there is a circulation of air which en
3. 120 Remove the casing knock out Remove protective cover and seal and place over the hole on the top make sure that the seal is positioned properly Tighten the assembly using the 3 M6 nuts The flue outlet spigot which you will find in a pouch in the stove and the holder for the upper flue diverter are assembled with 3 M6x20 head cap screws and M6 nuts The upper flue diverter baffle plate and top plate are assembled in reverse order ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 Installation distance in case of combustible wall To find out whether the wall next to where the stove is going to be installed is flammable you should contact your building contractor or the local building authorities The hearth should be able to accommodate the weight of the stove The chimney must be independently supported by wall brackets or a ceiling support plate The weight of the stove is indicated in the brochure The stove should always be installed on a non combustible hearth of a size and construction that is in accordance with the provisions of the current UK Building Regulations Approved Document J If the stove is to be installed on a wooden floor it must be covered with a noncombustible material at least 12mm thick in accordance with UK Building Regulations Approved Docu ment J to a distance of 300 mm in front of the stove and 150 mm to each side measuring from the door of the combustion chamber The clearance dis
4. 240 2001 2 2004 EC nr 407 Anordning til trae RONDO 92 Afstand til br ndbart bagv g 150mm Afstand til br ndbart sidev g 350mm Afstand til br ndbart m blering 1050 mm CO emission 0 1796 Reggas temperatur 246 C Nominel effekt E 5kW Virkningsgrad 80 Br ndsel Brug kun anbefalede br ndsler tr F lg instrukserne i brugermanualen Anordningen er egnet til r ggassamleledning og intervalfyring SINTEF Produktdokumentation 043 168 C Producent RAIS A S Industrivej 20 9900 Frederikshavn Danmark 07 EN 13240 2001 2 2004 EC nr 607 Anordning til trae RONDO 120 Afstand til braendbart 150mm Afstand til br ndbart sidev g 350mm Afstand til br ndbart drejefod 3609 1050 mm CO emission 0 17 Reggas temperatur 246 C Nominel effekt 5kW Virkningsgrad 80 96 Br ndsel Brug kun anbefalede br ndsler tr F lg instrukserne i brugermanualen Anordningen er egnet til r ggassamleledning og intervalfyring SINTEF Produktdokumentation 043 168 10 ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 Installation It is prohibited to carry out unauthorised alterations to the stove There must be plenty of fresh air in the room where the stove is being installed in order to ensure proper combustion Note that any mechanical exhaust ventilation e g an extraction hood may reduce the air supply Any air grates must be placed in s
5. 70 9896 Maple 540 9396 Birch 510 8896 Mountain pine 480 8396 Fir 390 6790 Poplar 380 6596 1 kg of wood fields the same heat energy irrespective of wood type 1 kg beech merely takes up less space than 1 kg of fir 18 ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 Drying and storage Drying wood takes time proper air drying takes approx 2 years Here are some tips Store the wood sawn split and stacked in an airy sunny place which is protected against rain the south side of the house is particularly suitable Store the firewood stacks at a hand s breadth apart as this ensures that the air flowing through takes the moisture with it Avoid covering the firewood stacks with plastic as this prevents the moisture from escaping It is a good idea to bring the firewood into the house 2 3 days before you need it Regulating the combustion air All RAIS stoves are equipped with a one handed operating lever for regulating the damp er The stove specific regulating mechanisms can be seen on the diagrams Primary air is the combustion air added to the primary combustion zone i e the bed of glowing embers This air which is cold is only used in the lighting stage Secondary air is the air which is added in the gas combustion zone i e air which contrib utes to the combustion of the pyrolysis gases preheated air which is used for the cleaner glass system and combustion This air is sucked through the damper under the com
6. ART FE OF FIRE USER MANUAL RAIS Rondo 92 8 Rondo 120 sjuudsiui Aue JO 9 qisuodsai aq M ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 Rais Rondo 92 Rais Rondo 120 Modified 2 Date December 2009 INTRODUCTION L cic e ta e a a o e e e E D a ae ce 4 WARRANTY c eI RE MEE oie LU c ga eei A 4 SPEGIFIGATIONS core E ERR ERR EE CO RET e ERE FREE Aer Ep 5 CONVECTION o E e d OS E RE e eee P cus 6 INSTALLATION INSTRUCTION ciedad rien eee 1 CHIMNEY e RR E RERO bed RE ER E ete defe sca 8 9 INSTALLA MON reete te E EE Rev ao DDR MS e 11 OPERATION OF SWIVEL BASE RAIS RONDO 120 11 ADJUSTMENT OF CHIMNEY CONNECTION 5 riti Arcs 12 13 INSTALLATION DISTANCE IN CASE OF COMBUSTIBLE WALL seem 14 GENERAL INSTALLATION RIGHT ANGLE SECURE BASE sss eee 15 CORNER INSTALLATION 45 15 360 SWIVEL BASE incio to rt EH EE 16 INSTALLATION DISTANCE IN CASE OF NON COMBUSTIBLE 16 FORTHE INSTALLER ree ete e RR NOR e Pr Ode eive qu had ERRORI set d te eed ee 17 OPERATING INSTRUCTION ER ERR ERROREM ERR Meta cit dep aS oe aa ER eR da 18 au edad c Moa cds una ear im 18 19 DRYING AND STORAQGE criss fick nere da 19 REGULATION OF COMBUSTION Alb eot zv re Er teet Re Hoi Hr ERR ES ER 19 R
7. IS Manual for RONDO 92 amp RONDO 120 Using the wood burning stove Adjustment of air damper The damper has 3 settings Position 1 Cue The air damper is closed which means no air supply Position 2 Push the lever to the right until it stops This position gives full secondary air During normal stoking the lever is set between posi tions 1 and 2 2 6 amp When the flames are clear and yellow the damper is set correctly i e resulting in a slow optimal burning Position 3 Lift the lever upwards and push to the right The air damper is completely open and gives full primary and secondary air The position is for the lighting stage and is not used under normal operation Control If the ash is white and the walls in the combustion chamber soot free after the stove has been used the air regulation was set correctly and the wood was sufficiently dry 20 ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 First usage A careful start pays off Start with a small fire so that the wood burning stove can get accus tomed to the high temperature This gives the best start and any damage is avoided Be aware that a strange but harmless odour and smoke concoction may emanate from the surface of the stove the first time you fire up This is because the paint and materials need to harden The odour disappears quickly but you should check the ventilation and draught if possible See also the IMPORTAN
8. OOM VENTILATION AND STOVES nice t rnt t e teer DR ter tre net d 19 USING THEWOOD BURNING STOVE A d o ree er oo 19 ADJUSTMENT OFAR PAMPER ete ei eer Cc ree i T e a eee e perc AER 20 CONTROL 5 RE DERE RERO ed e RE ELE ede 20 FIRST USAGE rc he o e i e e oe abb ee v tede nde dede e a te 21 LIGHTING AND FUELLING z s acte e rte cre te eee OR Dx e EO EO ce ed 22 23 CEEANINGAND CARE it ett EN Eat tet EOI oe MESE LUE 24 CLEANING OFTHE FLUE WAYS itr tr Rt ttr er t D De HR ter 25 INTERRUPTION OF OPERATION e coi rhe eee u ERE re enero 26 AGCESSORIES AND SPARE PARTS clic tnr cad eee rh REIR o Er EE De a ERE RR Rec AER ERES 27 SPARE PART DIAGRAMS RONDO 92 ge pained el ees edie dade oles 28 29 SPARE PART DIAGRAMS RONDO T20 rapere i ei t en tte OE Ee UE OCEAN ee ep 30 31 ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 Introduction Thank you for purchasing a RAIS wood burning stove These appliances have been ap proved by HETAS Ltd as intermittent operating appliances for burning wood logs only A RAIS wood burning stove is more than just a heat source it also shows that you care about design and quality in your home To make the most of your wood burning stove it is important that you read the manual thoroughly before installing and using it In the case of warranty coverage and for general queries regarding your wood burning stove it is important that you know the stove s
9. T warning notice below about persistent fumes During this process you must be careful not to touch the painted surfaces and it is recom mended that you regularly open and close the door to prevent the door seal from sticking The stove may also produce clicking noises during heating and cooling caused by the large temperature differences which the material is subjected to Never use any type of liquid fuel for kindling or maintaining the fire You could be at risk of explosion The stove gets very hot when in use always wear protective gloves when tending the stove If the stove has not been used for a while follow the steps as if you were using it for the first time IMPORTANT Warning Note Properly installed operated and maintained this appliance will not emit fumes into the dwelling Occasional fumes from de ashing and re fuelling may occur However persistent fume emission is potentially dangerous and must not be tolerated If fume emission does persist the following immediate actions should be taken a Open doors and windows to ventilate room b Let the fire out or eject and safely dispose of fuel from the appliance C Check for flue or chimney blockage and clean if required d Do not attempt to relight the fire until the cause of the fume emission has been iden tified and corrected If necessary seek expert advice IMPORTANT Warning Note Do not use an aerosol spray on or near the stove when it
10. bus tion chamber and is pre heated through the side channels and then emitted as hot scav enging air onto the glass The hot air rinses the glass and keeps it soot free The tertiary channel which can be seen at the the top of the combustion chamber to wards the back serves to combust the final gas residues By setting the interval between position 1 and 2 the energy content in the firewood is used optimally as there is oxygen for combustion and for the burning of the pyrolysis gases When the flames are a clear yellow the damper has been set correctly Finding the correct position comes with time after you have used for stove for a while It is not recommended that you turn it down completely A mistake commonly made is shutting the damper too early because it feels too hot This results in dark smoke ema nating from the chimney and in the calorific value of the firewood not being used to its fullest Room ventilation and stoves There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit smoke and fumes into the room The stove requires a permanent and adequate air supply in order for it to operate safely and efficiently In accordance with current Building Regulations the installer may have fitted a permanent air supply vent into the room in which the stove is installed to provide combustion air This air vent should not under any circumstances be shut off or sealed 19 ENGLISH RA
11. ccount must be taken of the guidance on the separation of combustible material given in Building Regulations Approved Document J and also in these stove instructions ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 If it is found that there is excessive draught in the chimney then either an adjustable flue damper or alternatively a draught stabiliser should be fitted The adjustable flue damper should not close off the flue entirely but should in its closed position leave a minimum continuous opening free area of at least 20 96 of the total cross sectional area of the flue or fluepipe Adequate provision e g easily accessible soot door or doors must be provided for sweeping the chimney and connecting fluepipe You should also familiarise yourself with the draught conditions for chimneys with 2 flues The flue outlet spigot is 150 mm in diameter For strong draughts the chimney or flue should be fitted with a draught stabiliser In which case itis important to ensure that there is a free flow through area of minimum 20 cm when the regulating gate is shut Otherwise the fuel energy may not be used optimally If at any time you are unsure about the condition of the chimney you should contact a chimney Sweep Remember that access to the access door should be kept clear ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 Rondo Manufacturer s Plate Producent RAIS A S Industrivej 20 9900 Frederikshavn Danmark 07 EN 13
12. e possible to access the clean out door ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 For the Installer Finally before firing the stove for the first time a check should be made to ensure that the assembly and stove installation has been satisfactory and that there are no leaks in any seals in the appliance and appliance connections to the chimney Ensure that the appliance and chimney flue are functioning correctly before finally handing over to the user If necessary read the later parts of this manual for guidance on care required when first lighting Inform the user that the appliance has been commissioned and ready to use and give in struction on the safe operation of the stove These Instructions must be left with the user and the user should be instructed to keep them in a safe place ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 Operating instructions Please note that HETAS Ltd Appliance ARROA only covers the use of dry seasoned wood logs on this appliance HETAS Ltd Approval does not cover the use of other fuels either alone or mixed with the wood logs nor does it cover instructions for the use of other fuels Fuel The stove is designed and approved in accordance with EN 13240 and NS 3058 for stok ing split dried firewood The firewood must have a water content of 15 2296 and its max length should be the length of the combustion chamber minus 50 60 mm Stoking with wet fi
13. el top plate with hole 7 1 5061090 95 8 1 5052207 Upper baffle plate 9 505222001 Firebrick set 10 1 607010490 95 Ash plate 11 5055500 Seal set 28 ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 Spare parts diagram RAIS Rondo 120 Pos Number Item no description 1 1 505700170 Soapstone top plate without hole 2 1 505700270 Soapstone top plate with hole 3 1 505060190 Top plate without hole 4 1 505060290 Top plate with hole 5 1 505061180 Stainless steel top plate without hole 6 1 505061280 Stainless steel top plate with hole 7 1 8142390 Ball coupling 8 1 5051090 95 9 1 6071590 Turn table 10 1 6071790 Air box 11 1 5052207 Upper baffle plate 12 1 505222001 Firebrick set 13 5055500 Seal set 14 1 607010490 95 Ash plate 30 ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 RAIS ART OF FIRE RAIS A S Industrivej 20 DK 9900 Frederikshavn www rais dk THE ORIGINAL
14. essary If it is found necessary to line the chimney then a flue liner suitable for solid fuel must be used in accordance with Building Regulations Approved Document J Any existing chimney must be clear of obstruction and have been swept clean immediately before installation of the stove If the stove is fitted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the stove and the open fire If there is no existing chimney then either a prefabricated block chimney in accordance with Building Regulations Approved Document J or a twin walled insulated stainless steel flue to BS 4543 can be used These chimneys must be fitted in accordance with the manufacturer s instructions and Building Regulations A single wall metal fluepipe is suitable for connecting the stove to the chimney but is not suitable for using for the complete chimney The chimney and connecting fluepipe must have a minimum diameter of 150 mm and its dimension should be not less than the size of the outlet socket of the stove which is 150 mm in diameter Any bend in the chimney or con necting fluepipe should not exceed 45 90 bends should not be used Combustible material should not be located where the heat dissipating through the walls of fireplaces or flues could ignite it Therefore when installing the stove in the presence of combustible materials due a
15. f time then it should be given a thorough clean to remove ash and unburned fuel residues To enable a good flow of air through the appliance to reduce condensation and subsequent damage leave the air controls fully open Prior to a new heating season it should be checked that the chimney and smoke gas con nector are not blocked 24 ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 Cleaning of the flue ways Remove the baffle plate by pivoting it Next remove the flue diverter by lifting it up up at one end and tilting it slightly at an and pulling it forward angle Carefully lift out the flue diverter Carefully pull out the plate Remove dust and dirt and assemble in reverse order 25 ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 Interruption of operation Smoke spillage around door Could be due to too low draught in the chimney 12Pa Check whether the flue or chimney is blocked check whether the extraction hood is switched on if it is switch it off and open a window door in the proximity of the stove for a short while Soot on glass Could be because the firewood is too wet make sure that the stove is heated properly when firing up prior to closing the door Could be because the damper regulation is too low A stove burning too strong could be caused by leak around the door seal chimney draught too large gt 22 Pa draught control regulator should be installed A stove burni
16. in the same room as the stove as this can cause the stove to emit fumes into the room e Ifthis appliance is installed into an existing chimney the chimney must first be swept and examined for soundness and suitability before the appliance is installed see also section headed Chimney ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 Chimney The chimney is the driving force which makes the stove function In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure the correct draught of 14 to 18 Pa so as to clear the products of combustion and prevent problems of smoke emanating into the room when firing NOTE A chimney height of not less than 4 5 metres measured vertically from the outlet of the stove to the top of the chimney should be satisfactory Alternatively the calculation procedure given in BS 5854 1980 may be used as the basis for deciding whether a particular chimney design will provide sufficient draught The outlet from the chimney should be above the roof of the building in accordance with the provisions of Building Regulations Approved Document J If installation is into an existing chimney then it must be sound and have no cracks or other faults which might allow fumes into the house Older properties especially may have chim ney faults or the cross section may be too large i e more than 230 mm x 230 mm Remedial action should be taken if required seeking expert advice if nec
17. ite at www hetas co uk It should be noted that the current Building Regulations requirements are given in Ap proved Document J These requirements may also be met by adopting the relevant recom mendations given in British Standards BS 8303 and BS EN 15287 1 WARNING Health and Safety Advice Notice The installation of this heating appliance is governed by the Health and Safety at Work Act 1974 It is the responsibility of the installer to ensure that all requirements of this Act are met during the installation works Attention is drawn in particular to the following Handling The appliance is a heavy item and adequate facilities must be available for loading unloading and site handling Fire Cement Some types of fire cement are caustic and should not be allowed to come into contact with the skin Protective gloves should be worn when handling fire cement In case of contact with the skin wash immediately with plenty of water Asbestos This stove contains no asbestos If there is a possibility of disturbing any asbestos in the course of installation then please seek specialist guidance and use appropriate protective equipment Metal Parts When installing or servicing this stove care should be taken to avoid the possibility of personal injury Important Warning Preparatory Work and Safety Checks This stove must not be installed into a chimney that serves any other heating appliance e There must not be an extractor fan fitted
18. ng too weakly could be caused by too little firewood too little air supply for room ventilation unclean smoke channels leaky chimney leakage between chimney and flue If your stove continues to malfunction we recommend that you contact your RAIS distribu tor or chimney sweep IMPORTANT To ensure safe burning there must be clear yellow flames or clear embers at all times The firewood should not be smoldering Therefore you should never completely cut off the air supply WARNING In case of chimney fire shut off all air supply on the wood burning stove contact the fire department never attempt to put out fire with water afterwards you should ask your chimney sweeper to check the stove and chimney 26 ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 Accessories and spare parts If spare parts other than those recommended by RAIS are used the warranty is voided replaceable parts can be bought as spare parts from your RAIS distributor See the following spare parts diagrams for the individual products 27 ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 Spare parts diagram RAIS Rondo 92 Pos Number Item no description 1 1 505700170 Soapstone top plate without hole 2 1 505700270 Soapstone top plate with hole 3 1 505060190 Top plate without hole 4 1 505060290 Top plate with hole 5 1 505061180 Stainless steel top plate without hole 6 1 505061280 Stainless ste
19. rewood causes both soot environmental pollution and bad fuel economy Freshly cut wood contains approx 50 7096 water and is thoroughly unsuitable for stoking Count min 1 year of storage time for newly cut wood before using Wood with a diameter of more than 100 mm should be split Regardless of wood size it should always have at least one surface area free of bark We do not recommend stoking with painted laminated or impregnated wood wood with a synthetic surface painted refuse wood chipboard plywood domestic waste paper bri quettes and pit coal as this will produce malodorous smoke which could be poisonous When firing with the above mentioned items and amounts larger than those recommend ed the stove is subjected to a larger amount of heat which results in a higher chimney temperature and lower efficiency This can result in the stove and chimney becoming dam aged and would void the warranty The calorific value of the firewood is closely connected to the moisture level of the firewood Moist firewood has a low heat value The more water the wood contains the more energy it takes for this water to vaporise resulting in this energy being lost ONLY USE RECOMMENDED FUELS The following table shows the calorific value of different types of wood which have been stored for 2 years and which have a residual moisture of 15 1796 Wood Kg dry wood pr m compared to beech oak Hornbeam 640 11096 Beech and oak 580 10096 Ash 5
20. sures that the heat is distributed more evenly throughout the entire room The cold air is sucked in at the base of the stove up through the convection channel which runs along the stove s combustion chamber The heated air pours out at the top of the stove which ensures a circulation of warm air throughout the room The stoves are equipped with a cold lever RAIS special feature which means you could almost do away with gloves Be aware however that all exterior surfaces become hot during use so take extreme care ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 Installation instructions The following pages give instructions for the safe and proper installation of this heating ap pliance in the UK These instructions cover the basic principles of installation although detail may need slight modification to suit particular local site conditions In all cases the installa tion must comply with current UK Building Regulations Local Authority Byelaws and other specifications or regulations as they affect the installation of the stove Please note that itis a legal requirement under England and Wales Building Regulations that the installation of the stove is either carried out under Local Authority Building Control approval or is installed by a Competent Person registered with a Government approved Competent Persons Scheme HETAS Ltd operate such a Scheme and a listing of their Registered Competent Persons can be found on their webs
21. tances to combustible material beneath surrounding or upon the hearth and walls adjacent to the hearth should comply with the guidance on the separation of com bustible material given in UK Building Regulations Approved Document J and also in these stove instructions ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 Normal set up right angled secure base RONDO 92 A Distance to furniture 1050 mm Distance to flammable materials B in front floor 300 mm C to the side floor 150 mm D rear wall 150 mm E to the side of the wall 350 mm RONDO 120 1050 mm 300 mm 150 mm 150 mm 350 mm Y Corner set up 45 RONDO 92 A Distance to furniture 1050 mm Distance to flammable materials B in front floor 300 mm C to the side floor 150 mm D rear wall 150 mm E to the side of the wall 350 mm RONDO 120 1050 mm 300 mm 150 mm 150 mm 350 mm ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 360 swivel base normally placed as a room divider RONDO 120 A Distance to furniture 1050 mm Distance to flammable materials B in front floor 300 mm Distance to firewall 800 mm PUN ES D 1 LG Y qq LO PES e Installation distance in case of non combustible wall We recommend a minimum distance to non combustible material of 50mm F for cleaning considerations It should always b
22. uch a manner that the air supply is not blocked Building Regulations Approved document J gives specific guidance on the required permanent ventilation into the room for combustion air of solid fuel appliances The floor structure must be able to carry the weight of the wood burning stove as well as the weight of a chimney if necessary When you choose where to set up your RAIS wood burning stove you should consider the heat distribution to the other rooms This will enable you to get the best use out of your stove The stove should be set up at a safe distance from inflammable materials See the manufacturer s plate on the wood burning stove Installation with turntable RAIS Rondo 120 If the stove has a turntable then please do the following Push pull the pedal in 15 intervals When the stove is in the desired position let go of the pedal and turn the stove lightly until it slips into place ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 Adjustment of chimney connection The stove is always delivered for top connection but can be changed to rear connection as follows Remove baffle plate and smoke diverter see clean ing and care Loosen the 3 M6 nuts with a wrench key Make sure that the flue diverter is fastened to the protective cover Lift up the reflector plate push out the knock out and put the reflector plate back into place ENGLISH RAIS Manual for RONDO 92 amp RONDO
23. x 5 min or when the flames are clear and stable close the damper gradually It is recommendable to have a layer of ash of ap prox 20 mm as it has an insulating effect Note During operation the door should always remain shut ENGLISH RAIS Manual for RONDO 92 amp RONDO 120 Cleaning and care The wood burning stove and the chimney must be serviced by a chimney sweep twice a year During cleaning and care the stove must be cold If the glass is sooty Moisten a piece of paper or newspaper dip it in the ash and rub the sooty glass with it Now rub with a piece of paper and the glass will become clean As an alternative you can use glass polish which you can buy from you RAIS distributor Clean the exterior with a dry sponge Cleaning soapstone Normal cleaning is done with a tightly wrung cloth If necessary the soapstone can be cleaned with a normal diluting agent from a paint store If there are stains which the dilut ing agent cannot handle it is possible to abrade the stone slightly Cleaning the combustion chamber Scrape shovel the ash out and store it in a non flammable container until it has cooled down You can dispose of ash with your normal household waste REMEMBER Never remove all the ashes from the combustion chamber the wood will burn at its best with a layer of ashes of approx 20 mm Prolonged periodes of non use If the stove is to be left unused for a prolonged period o

Download Pdf Manuals

image

Related Search

Related Contents

FR - Jaeger  56F805 - HW.cz  取扱説明書・据付工事説明書    MODEL CX06 6” WOODWORKING JOINTER  Les Côtes La Poya Beaurevoir Vieux Donjon Mollard Pichon    pour en savoir + télécharger le grand guide du tri - Tous éco  LEDライトアップ照明ラウンドライトアップ照明マニュアルはこちら  Conjunto de Sensor Modelo OI-6000  

Copyright © All rights reserved.