1. foam base The cells are inflated alternately one out of two except for the 3 head cells which remain static The whole is protected by an integral removable waterproof and breathing cushion incorporating a pillow D HOW IT WORKS e The alternating pressures prevent prolonged vascular compression which may lead to histohypoxia e The low pressure static mode enables you to handle patients who need to be immobilised fractures neurological trauma etc in order to reduce to a minimum local trauma helping the patient to rest or carrying out transfer preparations before setting up a static mattress e The care mode helps with the ergonomics of some care procedures e The inflation level can be adjusted automatically You use the pressure adjustment to adapt the mattress to the patient s morphology and position Pressure should be calculated when the patient is lying down and calm ASKL SANT AXTAIR E INDICATIONS In the opinion of the Committee for Evaluation of Goods and Services published in the Journal Officiel on 21 July 2005 and in the opinion of clinical experts Prevention and aid to treatment of eschars from stages to 4 according to medical opinion in patients confined to bed for more than 15 hours presenting with a risk of eschars assessed against a validated scale and clinical judgment Patients whose weight cannot be determined F PRECAUTIONS Non stabilised and or muscular trauma in contact with the supp
2. WINZICARE User manual ASKLESANTE ASKLO UNITY afa DAN Tre LE PA0010085x Qualit S curit Sant M dical Environnement AFNOR CERTIFICATION AFNOR CERTIFICATION MAJ 23 10 2014 UK ASKL SANT AXTAIR A SCONTENTS OF THE PACKAGING east 3 B MEANINGS OF THE COMPRESSOR PICTOGRAMS rm 3 Go DESCRIPTIONS e e uM DEM LL UI EA 3 Dr SOWIE WORKS cce A EU ML IE D 3 E CINBICABONSSS e tite LI te UL M E E 4 p PRECAUMONS car Li ML D RM ME M LEE desc 4 Gr SPECIFICATION e ee eL ee te 5 e o A n Lie ML D RM ME MM ELE ee UL M IE E 6 l NE A EE E UU LEE 8 M cr EE 9 kc MAINTENANCE DIN ON paseos sra ud use dui crede Laid 10 O a A DM i unes tt 10 A LU UU EE 12 N DISPOSAL OF THE MEDICAL DEVICES esse sense messe 12 SS A A A E 12 ASKL SANT AXTAIR A CONTENTS OF THE PACKAGING mattress rolled in a transport bag integrated compressor in rolled up mattress electric power cable which has 2 ways of being attached to the bed user manual MEANINGS OF THE COMPRESSOR PICTOGRAMS Caution read the user manual and or instructions for use E Class Il appliance double insulated Y Caution electrical and electronic equipment only to be disposed of in a special waste collection Type BF electrical appliance i Compliant with the essential criteria in European Directive 93 42 CEE applicable to medical devices ae RN C DESCRIPTION The mattress consists of 18 air cells 12 cm in height placed on a 5 cm
3. aterial upper section PROMUST PU HD Jersey Polyurethane Cushion material lower section Non slip PU PVC Cell material Polyurethane ether 300 um SPECIFICATION OF THE AUTOMORPHO COMPRESSOR Alternating mode cell out of 2 Alternates every 7 minutes Low pressure static mode Automatic pressure control dependent upon the patient s morphology Manual optimisation in semi seated position gt 50 Static mode for care closed plan Pump Flow Indicative value gt 7 litres min Mattress inflation time Less than 20 mins for an Automorpho Approx 30 minutes for an Automorpho XL Approx 2 minutes with a VKIT AXT high speed inflation pump Removable particle filter Audible output lt 35 dBA to NF EN ISO 3744 1995 Audio visual alarms Power supply 220 240 volts Length of power cable 4m Fusible 630 mAT Mean output 5 watts Class Il protection against electric shock Compliance certificate IEC 60601 1 amp 60601 1 2 Guarantee 2 years against any manufacturing defect Working life 5 years ASKL SANT AXTAIR H CONTROL PANEL ASKL SANT Start stop button This button starts or stops the compressor The button is pressed in the normal way to start the compressor and held down to stop it a Keyboard locking button This button locks the touchpad simply hold it down for approximately 4 seconds to avoid accidental selections The touchpad defaults to locked after it has not been used
4. atic makes the surface of the mattress firm in order to simplify handling of the patient during care or when lifting e g transfer from bed to armchair A WARNING For safety the care mode is enabled for 30 minutes after 25 minutes an audio signal 3 BEEPS warns that the mode is almost ended and the light flashes At the end of 30 minutes the compressor reverts automatically to the previous mode Settings This zone is used to set the parameters Press the corresponding button to adjust the settings The blue lights come on continuously to validate the selection Pressure button this runs a pressure calculation with an AUTOMORPHO compressor at any time A steady light means that the calculation is OK Pressure level indicator low medium or high It should be selected for a sitting position greater than 30 This button adjusts the pressure according to the position of the patient HINT n some cases if the slope of the bed chest elevator is greater than 30 you may have to increase the pressure inside the cells for the comfort and safety of the user Press the key and a blue light comes on We recommend that you limit the time in the semi seated position at 45 to a maximum of 2 hours to reduce the risk of eschar Alarms This zone is devoted to alarms 5 Audio visual alarm indicating abnormal pressure the indicator flashes and a bell sounds if the pressure is too low or too high and in this way warns of lea
5. bjects Risk of damage to the equipment N DISPOSAL OF THE MEDICAL DEVICE ENVIRONMENTAL PROTECTION This appliance contains a variety of recyclable materials Y This symbol indicates that this equipment is recyclable and that worn out appliances should not be mixed with other waste Devices will therefore be recycled under the best possible safety conditions in order to limit effects on the environment and human health if hazardous substances are present in accordance with European Directive 2002 96 CE concerning electrical and electronic equipment waste at the end of its working life You can contact the store reseller or distributor from whom the product was bought to find out the collection points for worn out devices closest to your home Before any disposal the appliance must be cleaned in accordance with the instructions in K SERVICING DISINFECTION to avoid any risk of contamination We are grateful for your co operation in protecting the environment O WARRANTY The compressor and the mattress are guaranteed for 2 years against any manufacturing defect starting from the date of purchase and subject to use under the conditions recommended in the user manual This guarantee does not replace the legal guarantees In order to claim under the warranty it is essential that you keep the bill for the purchase of the product If there is a manufacturing defect and if the product is still under warranty please contact your distributor and g
6. ed Do not iron Do not dry clean or use solvent based stain removers a co By Tumble drying permitted moderate temperatures Item treated with a biocidal substance that is safe for the user www winncare fr The MANUFACTURER will provide on request wiring diagrams lists of components descriptions calibration instructions or any other relevant information to SERVICING and MAINTENANCE STAFF in order to carry out permitted repairs in accordance with the contract between the applicant and ASKLE the manufacturer L MAINTENANCE SERVICING Periodic servicing of AUTOMORPHO AXTAIR compressors is advised in order to maintain an ideal operating specification O o The periodic servicing interval recommended is indicated by the servicing light on the control panel coming on This servicing can only be carried out by authorised persons contact your reseller 10 ASKL SANT AXTAIR Flow chart of recommended cleaning and disinfection R ception Dispositif Complet Pr Traitement de surface D contamination R partition de surface par ufibres Solution base alcoolique EPI masque Hygi ne gants tablier Housse Alt r e Elimination par la fili re d chets Housse de remplacement identique la protection d origine OUI Propret phvsiaue Entretien de surface M thode 1 Op ration Produit D tergent D sinfectant EPI gants tablier Entretien de surface Lava
7. for 5 minutes B Waiting indicator This orange indicator flashes when the compressor is in operation Example initial inflation Servicing indicator This orange indicator lights up continuously if servicing of the compressor is advisable The indicator flashing together with an alarm sound indicates a problem with the distributor In this case please contact your reseller See L MAINTENANCE SERVICING Mains indicator This orange indicator when on permanently indicates that the compressor is connected to the mains source of electrical energy even if the compressor is not working Audio alarm cut off button This button cuts off audio alarms Each modification or selection parameters or functions is signalled by an audible BEEP A selection error is signalled by 3 very rapid BEEPS ASKL SANT AXTAIR Operating modes This zone selects one of the three possible operating modes Pressing the button corresponding to the mode enables it The green light comes on continuously to validate the selection m Low pressure dynamic mode enables alternating of one cell out of two except for the 3 head cells The cycle change is made every 7 minutes ES pressure static mode inflates all the mattress cells to a constant pressure equal to the lowest internal pressure and allows the patient to sink into the support so as to increase the supporting area and thus reduce the average interface pressures Care mode st
8. ge housse en machine a 90 C D tergent D sinfectant D tergent Expertise du produit Contr le Qualit Canfarma OUI Assembler Enregistrer Spray de surface D tergent D sinfectant EPI masque d hygi ne Lib ration du produit Conditionnement Alcohol based broad spectrum disinfectant cleaner standardised bactericide EN1040 EN13727 Fungicide ENI275 ENI3624 NF T72 190 Sporicide EN13697 EN14561 Polyvirus EN14476 HBV HCV Restrict spraying of cells Detergent Disinfectant for cleaning floors and surfaces Positive list of disinfectants Neutral detergent domestic cleaning product ASKL SANT AXTAIR M STORAGE A bag is provided for transport and storage of the mattress which must be rolled Total deflation of the mattress is easier if you use the inflation deflation pump connected to the CPR OPEN position The compressor can be placed inside the bag The following label identifies the cleaning state of the AXTAIR device QHTQIF Blue label when the mattress is clean Yellow label if there is a risk that the mattress is contaminated Temperature conditions minimum 10 C maximum 40 C Relative humidity conditions minimum 30 maximum 95 A WARNING O Keep the devices away from any source of damp direct sunlight or a source of continuous heat Risk of damage to the equipment O Prevent any risk of impact or damage by sharp or cutting o
9. ience the patient during the night Pressing a key resets maximum intensity for 30 minutes A WARNING for a precise pressure calculation the patient should be lying flat on the bed and should not make any sudden movements WARNING the power lead should be should be installed so as to avoid any interference with the articulated parts or the wheels of the bed and employees cannot trip over it There is a risk of physical injury and damage to the equipment Use the removable hooking systems supplied ASKL SANT AXTAIR J ALARMS If there is a pressure alarm the red indicator will flash and an intermittent audio signal will sound The audio signal can be cancelled by pressing the E button Check the feed pipe connection to the compressor and that the CPR valve is closed Check that the air lines are positioned and connected correctly and not split Check that there are no leaks in the cells structure connection Replace defective parts if necessary pipes cells etc If the problem persists contact your reseller When the pressure returns to normal the compressor will revert to normal operation and the indicator will go out Nn aun If there is an electrical fault alarm the red indicator will flash and a continuous audio signal will sound The audio signal can be cancelled by pressing the E button I Check that the compressor is still connected to the pump and to the power point and that the mains indicator is o
10. ive him the product in question He will take the necessary steps with our company either to repair it or to make a standard exchange A WARNING There is a warranty seal under the label on the side of the compressor The presence is your guarantee that the compressor passed all its inspection tests successfully and that it is tamper resistant If this label is removed by the user or an unauthorised third party the integrity of the compressor is no longer proven ASKLE may refuse to repair it under warranty and is entitled to terminate same i ASKL SANT DISTRIBU PAR Avec Ecofolio papiers tous les papiers se recyclent ASKL SANT Groupe Winncare 200 rue Charles Tellier Actiparc de Gr zan 30 034 Nimes Cedex 1 France T l 33 0 4 66 02 15 15 Fax 33 0 4 66 02 15 00 Email contact askle com www winncare fr
11. ks or pump failures ke Audio visual alarm indicating an electrical fault the indicator flashes and a bell sounds if the power supply is cut off or the power lead is disconnected or altered ASKL SANT AXTAIR l INSTALLATION USE Unroll the mattress Position it on the base of the bed ensuring the cushion head and foot symbols are placed correctly Hook the compressor to the bed frame the foot Guide the power lead for the compressor along the bed to the nearest power point and connect it B If you have a high speed inflation pump after stage 4 Connect the power lead for the inflation pump to the mains Blank off the connection to the mattress feed pipe with the attached plug Set the CPR valve to OPEN Connect the high speed inflation pump as shown in the diagram below Comment the pump inflates in one direction and deflates in the other Press the start button until the mattress appears to be fully inflated approximately 2 minutes Z wNMN Close the mattress CPR valve set the dial to CLOSE Connect the mattress feed pipes to the compressor connector Press the Start Stop button The lights come on for second and a BEEP sounds Wait until the Wait indicator stops flashing indicating the end of the auto inflation phase Without high speed inflation this step lasts about 20 minutes for a mattress 87 cm wide and 30 minutes for a mattress 7 cm wide 9 Lay the patient out flat o
12. n 2 Ifthe problem persists we advise you strongly to disconnect the air lines blank them off with the transport plug and move the patient regularly When the power supply returns you must restart the compressor by pressing the Start Stop button while repeating the INSTALLATION USE instructions I starting from step 8 after you have reconnected the mattress feed pipe to the compressor A COMMENTS On starting the compressor there is an initialisation step If there is a fault an alarm is indicated by rapid flashing of all the indicators or depending on the type of problem by the servicing indicator flashing f the compressor is disconnected even temporarily there is always an electrical fault alarm to warn against accidental handling A WARNING After accidental deflation of the mattress due to a prolonged power cut check at the time of reflation that the patient does not have a limb wedged between the mattress and the bed sidebars CPR Emergency Cardio Pulmonary Resuscitation In case of cardiac arrest l Turn the end of the CPR valve to set the dial to OPEN 2 The mattress will deflate and the back of the thorax will be in less than 15 seconds on the firm base of the bedframe to allow External Cardiac Massage ASKL SANT AXTAIR K MAINTENANCE DISINFECTION MA RISK OF ELECTRIC SHOCK e Before any maintenance disconnect the equipment from its power supply in order to avoid any risk of physical injury o
13. n the mattress ol ade 10 Start a pressure calculation by pressing the button while the LED is flashing If you do nothing the calculation will start automatically after a 5 minute pause During the calculation the pressure button indicator stays on and the pressure indicators come on alternately For a precise calculation the patient should not move excessively The calculation lasts a maximum of 6 minutes When the calculation is finished the pressure button indicator goes out and the pressure indicators are lit continuously to indicate that the pressure is now matched to the patient s morphology The compressor then starts DYNAMIC mode automatically Il Selecting the position corresponding to that of the patient see CONTROL PANEL A COMMENTS 9 Unlock the keypad before making selections by holding the button down for a little while Example to change mode e To recalculate the inflation pressure press again on the pressure button and the pressure indicators will come on alternately e If installation was completed without the patient present you must rerun the calculation once the patient is lying on the mattress 9 t is possible exceptionally to modify the setting obtained by automatic calculation by holding the pressure button down e The principal information for using the compressor is printed on its side O After 30 minutes has passed without selection the intensity of the indicators reduces in order not to inconven
14. ort Days immediately following surgical intervention on eschar skin graft or pedicled graft gt prefer static mode Patient monitored at home without the possibility of intervention by medical auxiliaries The device must not be used in a hyperbaric chamber A WARNING According to appendix to European Directive 93 42 CEE relating to the essential criteria applicable to medical devices only compatibility between systems assembled by the manufacturer ASKLESANTE guarantees a safe combination when using the AXTAIR motorised air mattress The specification and performance of the motorised air support will only be maintained by using the AXTAIR pump ref VAXT4 POMPE AUTO associated with the AXTAIR mattress ref VAXT4 MA AUTO or VAXT4 MA XL and optionally the inflation deflation kit ref VKIT AXT The national authority responsible for health and safety and health products can at any time institute audits of the conditions under which said products are marketed and take the measures necessary if there is danger or a breach of the rules In the event of failure to comply with the abovementioned conditions of use the user s liability may be committed if there is an accident PLEASE NOTE The compressor and the mattress are still compatible with the products with equivalent references from previous ranges ASKLESANTE AXTAIR G SPECIFICATION MATTRESS SPECIFICATION Rapid deflation CPR valve less than 15 seconds Cushion m
15. r damage to equipment e Never expose the equipment to sprayed water RISK OF DAMAGE TO THE EQUIPMENT You must not use corrosive cleaning products such as industrial degreasing agents solvents of the acetone type and ether You must not use abrasive materials such as steel wool or ScotchBrite Compressor Use a cloth lightly soaked with a detergent or surface detergent disinfectant solution marked CE at the concentrations for use recommended by the manufacturer Observe the remanence time Please note In order to prevent any damage to the compressor through liquid getting inside the casing please do not spray the product The filter should be changed time per year or more frequently depending on environmental conditions dust smoke Mattress Disinfection by hand use a cloth impregnated with a solution of detergent or surface detergent disinfectant marked CE at the concentrations for use recommended by the manufacturer Observe the remanence time The removable foam base can be replaced in case of alteration Ref VAXT3 MS support x4 Base gt 5cm CE marking compulsory under directive 93 42 CEE for products claiming that they are suitable for the surfaces of Medical Devices Cover Observe the following washing conditions Wash in water maximum temperature 90 C reduced mechanical action rinsing in decreasing temperature spin drying Pe E S 1 3 Bleaching possible chlorination at 000 ppm permitt

Download Pdf Manuals

image

Related Search

Related Contents

Descargar  Field Service Manual Rev-01  Benq MS510  Bedienungsanleitung User Manual Mode D'emploi  user`s manual pdb-1800  co-911-8 manual de usuario  Evolving Technologies Black X Duet  instrucciones de instalación y mantenimiento detector de humo por  CT-3500 S2  Bissell CleanView 3593 User's Manual  