1. v MiIMOlite Multiple Input Multiple Output Products that speak Z Wave Wireless Interface Bridge Module User Manual iach Introduction The MIMOlite Module is an interface bridge module capable of converting a wired or wireless input to a wired or wireless output The MIMO is a Z Wave Wireless device compatible with other Z Wave certified products MIMOlite comes in a plastic enclosure for indoor use only Specifications Power 9 24 V DC 300mA Frequency Range 908 4MHz US 868 4MHz EU Distance Range Max 100ft line of sight in unobstructed environment Enclosure Size L x W x D 3 3 8 85mm x 2 1 2 64mm x 1 1 4 30mm Weight 4 oz 100 gram Operating Temperature 10 C 14F to 70 C 158F Input Signal 1 SIG1 Digital or Analog Input 0 to 24V DC 16 Hz Max for pulse counting min 32 ms high or low time The trigger levels and hysteresis can be set via the Configuration Command Class The input can be a dry contact closure see open shorted characteristics in Technical Appendix Input Signal Impedance Input impedance for SIG1 is Z2 66 ohm at 10KHz This impedance is 66 ohm 34 ohm j 540uH Output Relay 1 DPDT Max Switching power of 120W 10uA to 10A High Dielectric strength coil contacts 1 000 VAC Open contacts 750 VAC Conforms to FCC Part 68 requirements Ag Au clad bifurcated contacts fully sealed System Requirement Any Z Wave enabled network and controller Overview The MIMO
2. complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Contains Transmitter Module FCC ID XCT Z3US FCC Warning Part 15 21 Changes or modifications not expressly approved by the party responsible for compliance could void he user s authority to operate the equipment FCC Interference Statement Part 15 105 b This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Co 1080 Centre Rd Ste C Phone 248 481 7092 F R T R E Z 7 Auburn Hills MI 48326 sales fortrezz com www fortrezz com
3. 4 Die MIMOlite Multiple Input Multiple Output Products that speak Z Wave Wireless Interface Bridge Module User Manual iceman MIMOlite functionality is based on wireless RF transmissions Any wireless transmission can be subject to RF interference or loss of communication This interference or loss of communication may cause the unit to not operate as intended You the end user are responsible for ensuring that the MIMOlite functionality and installation meet your desired requirements Do not mount the MIMOlite inside a metal enclosure Do not place MIMOlite on or near metal objects This decreases range and or blocks wireless transmissions Information provided in this manual is for your convenience and may be superseded by updates The specifications and this manual are subject to change without notice It is your responsibility to ensure that the MIMOlite functionality meets your needs and specifications Using the MIMOlite in a Z Wave Network INCLUSION in adding to a network 1 Set up the inclusion mode at the controller for detailed directions please refer to your controller user manual 2 If the LED has a periodic single blink the unit will be automatically included Otherwise the button has been previously pressed and automatic inclusion mode is no longer active In this case briefly press the button once and the controller will indicate that the unit has been included in the network Also the Status L
4. ED will blink when the inclusion completes Inclusion and exclusion are always done at normal transmit power mode EXCLUSION from removing from a network 1 Set up the exclusion mode at the controller for detailed directions please refer to your controller user manual 2 Press the MIMOlite button and the controller will indicate the unit has been removed from the network The Status LED will blink when the exclusion completes ASSOCIATIONS Once in a network your controller can be used to associate the MIMOlite with other devices in the Z Wave network such as a light or remote audible alarm Refer to your controller s documentation on how to associate the MIMOlite with another device in your network The MIMOlite input supports five association groups with a maximum of two associated devices in each group Group 1 When the input is triggered untriggered a command is sent to turn on off the device s associated with the input Group 2 The MIMOlite will periodically send a report indicating the input s analog voltage level Group 3 If a power dropout occurs the MIMOlite will send a notification depending on available residual power Group 4 When the input is triggered or untriggered a Binary Sensor report is sent to this group s associated device s Group 5 Pulse meter counts will be sent to this group s associated device s STATUS INDICATIONS The MIMOlite provides a status light to indicate various situations As shown i
5. Made in USA 011814 AL MiIMOlite Multiple Input Multiple Output Products that speak Z Wave Wireless Interface Bridge Module User Manual iceman Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Industry Canada Statement per Section 4 0 of RSP 100 The term IC before the certification registration number only signifies that the Industry Canada technical specifications were met Section 7 1 5 of RSS GEN Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation From section 5 2 RSS Gen Issue 2 June 2007 Equipment Labels Contains IC 8156A Z3X From section 7 1 1 RSS Gen Issue 2 June 2007 a The host device as a stand alone unit without any separately certified modules complies with all applicable Radio Standards Specifications b The host device and all the separately certified modules it contains jointly meet the RF exposure compliance requirements of RSS 102AA if applicable c The host device complies with the certification labeling requirements of each of the modules it contains Europe The MIMOlite module has been certified for use in European countries Test standar
6. d ETSI EN 300 328 V1 7 1 2006 10 The Waste Electrical and Electronic Equipment WEEE directive 2002AA 96 EC was approved by the European Parliament and the Council of the European Union in 2003 This symbol indicates that this product contains electrical and electronic equipment that may include batteries printed circuit boards liquid crystal displays or other components that may be subject to local disposal regulations at your location Please understand these regulations and dispose of this product in a responsible manner Limited Warranty THE PRODUCT IS PROVIDED WITH ONE YEAR LIMITED MANUFACTURER WARRANTY FORTREZZ LLC warrants its products to be free from defects in material and workmanship under normal use for one year and is not responsible for consequential damages or installation costs of any nature FORTREZZ LLC expressly disclaims all implied warranties including but not limited to the implied warranties of merchantability and fitness for a particular purpose FORTREZZ LLC does not warrant guarantee or make any representations regarding the use or the results of the use of the products or any accompanying materials in terms of their correctness accuracy reliability or otherwise In no event shall FORTREZZ LLC be liable to Purchaser hereu nder or in respect of any products ordered or delivered to Purchaser whether in contract tort including negligence or otherwise for a loss of profits or loss of use or for any incidenta
7. esistor The trigger ranges for SIG1 are very flexible and can be changed to meet many application requirements Refer to the Technical Appendix for details 1080 Centre Rd Ste C Phone 248 481 7092 7 F O R T R E z Auburn Hills MI 48326 sales fortrezz com www fortrezz com Made in USA 011814 AN MIMOlite Multiple Input Multiple Output Products that speak Z Wave Wireless Interface Bridge Module User Manual ei Output Configuration The MIMOlite can be configured to automatically turn the relay on when the input is triggered or a Z Wave command can also turn the relay on The Configuration Command Class Parameter 3 is used to set the input to relay mapping See Technical Appendix When input to relay mapping is enabled Z Wave commands to set the relay are overridden The default for the relay is no input to relay mapping Momentary vs Latched relay operation is selected by jumper P5 on the circuit board The Momentary Latched jumper is read only at power on when the MIMOlite is not in a ZWave network When the jumper is off momentary default 500ms operation is selected If desired once in network a Zwave configuration command Parameter 11 can be used to override the jumper setting The momentary configuration can be set from 100ms to 25 5ms approximate in increments of 100ms via the ZWave command refer to the Technical Appendix Power Dropout A periodic Power Dropout indication see above table is shown i
8. f the supplied power drops below approx 10 5 Volts Also the MIMOlite implements the Alarm Command Class which provides an alarm report Alarm Type 0x08 Alarm Level OxFF when the supplied power drops The MIMOlite sends the alarm report to the node s in Association Group 3 After a power dropout alarm event the MIMOlite sends an alarm report Alarm Type 0x08 Alarm Level 0x00 when the supplied power rises above approx 11 Volts Installation Depending on your intended application place Apply DC power to PO Do not exceed 24VDC Connect monitored signal to SIG1 P1 labeled jumper on P5 2 pin connector beside P3 for Program MIMOlite into your Z Wave and and relay contacts NO NC COM on P4 Latched relay function leave jumper ON for controller with the button located next to PO Follow polarity and do not exceed max input Momentary relay function remove jumper voltage of 24V DC or 16Hz if counting triggers Troubleshooting The MIMOlite has been tested with controllers from various vendors However it is not possible to test with every controller on the market For specific troubleshooting procedures please refer to your controller instruction manual and or contact your controller manufacturer Also check the FortrezZ LLC website www fortrezz com for helpful FAQs a Technical Appendix with more details and updates to this User Manual Regulatory Information FCC Compliance Statement Statements This device
9. l consequential special or indirect damages howsoever caused whether or not FORTREZZ LLC has been advised of the possibility of such loss or damage FORTREZZ LLC s maximum liability to Purchaser under these conditions shall in no event exceed the amount paid by Purchaser for the products that are the subject of the claim and in respect of all claims for products ordered from FORTREZZ LLC to which these conditions apply to the amount paid by Purchaser for the products which are the subject of the claims If you are not comfortable with your limited warranty or not completely satisfied with the MIMOlite or the MIMOlite does not perform as expected we encourage you to return the MIMOlite to your DISTRIBUTOR for an exchange or for a full refund within 30 days of purchase Or you can return the MIMOlite to FORTREZZ with an RGA number All products to be returned to FORTREZZ LLC must have a valid Returned Goods Authorization RGA Send the returned unit to FortrezZ LLC Warranty Replacement 1080 Centre Rd Ste C Auburn Hills MI 48326 postage prepaid with a payment of USS 9 95 to cover the cost of return shipping postage and handling You must use the original packaging and include a proof of urchase photocopy of receipt along with the RGA and the returned product 1080 Centre Rd Ste C Phone 248 481 7092 orrrezZ F O R T R E z Auburn Hills MI 48326 sales fortrezz com www fortrezz com Made in USA 011814
10. lite module provides one analog or digital input and one relay output isolated dry contacts NO COM NC and can be controlled by Z Wave The system includes a program switch for Z Wave inclusion exclusion and a status light LED for various indications Input SIG1 is an analog input internally pulled up to the MIMOlite supply voltage The system allows trigger conditions to be set based on the input voltage being inside or outside a user defined range configured via Z Wave This provides great flexibility for capturing events in a wide variety of applications The trigger status of the input can be read via Z Wave and or can be automatically sent to a configured node typically the Controller In addition a count of the trigger events that have occurred for the input channel is internally recorded and stored in the pulse count and is available to be requested or automatically sent via Z Wave The current triggered un triggered status can also be read via Z Wave The SIG1 input can be associated with up to two other Z Wave devices such that an associated device will automatically turn on or off based on the occurrence of a trigger event Finally the analog input channel can be configured so that the analog input level not just binary trigger status is periodically sent to up to two other associated nodes The output relay is typically commanded via Z Wave commands In addition the user can configure the input SIG1 trigger co
11. n the table below the light blinks a variable number of times fast or slow periodically or only once Network Wide Inclusion Mode NWI mode is automatically entered at power up when MIMOlite is not in network m MIMOlite in network indication after inclusion power up MIMOlite is not in network after button is pressed during NWI mode or if inclusion fails or after exclusion a Power input has dropped out voltage has dropped to below approx 10 5V Input Analog to Digital Characteristics The input signal voltage conversion to Multilevel Sensor value ADC reading or count is non linear A typical conversion curve Voltage to ADC reading is shown in the Technical Appendix on the FortrezZ website These are the values returned via the Multilevel Sensor report in response to a Multilevel Sensor Get request or if association Group 2 is set up The conversion is a 12 bit conversion which allows values from 0 to 4095 Input Configuration The voltage conversion described above also applies to the triggering configuration Refer to the Technical Appendix for details on changing the triggering configuration The default trigger configuration for the analog input SIG1 is a threshold around 1V That is the input will trigger when the level goes above approximately 1V and will untrigger when the level goes below approximately 1V If the input is left open the input will remain triggered because of the internal pull up r
12. ndition to be mapped to the output relay For example Relay 1 can be automatically turned on based on Input SIG1 being triggered The relay activation can be set via a jumper or via Z Wave for either momentary or latched operation see Installation section Warnings and Precautions The dry contact relays are not capable of supporting higher than specified loads Exceeding the specified switching power will cause damage to the unit and may cause damage to property and or personal injury including loss of life WARNING Do not attempt to use the relays to switch residential or industrial Alternating Current AC lines The relays are to be used for low power load control only Refer to above electrical specifications for relays Do not store highly flammable items such as oily rags or other combustibles near your MIMOlite Do not apply electrical power to the unit unless the unit is fully assembled Install unit in accordance with electrical codes and regulations In case you are unsure about any parts of these instructions consult an electrician or Z Wave home automation specialist Disconnect power source before working on or servicing the unit Failure to do so could result in personal injury WARNING The MIMOlite must not be used in life support and or safety applications 1080 Centre Rd Ste C Phone 248 481 7092 r i F O R T R E z L Auburn Hills MI 48326 sales fortrezz com www fortrezz com Made in USA 01181