WS 9006 instruction manual User Manual 1. Features

image

Contents

1. display on the LCD hold SEARCH button B3 on the main unit for 3 seconds to receive transmission manually 7 2 Rain Sensor Alarm e Intime setting mode select the rain alert on off bee Symbol appear on the display if rain alert function is activated ioe e When raining the alarm signal will sound for around 2 minutes symbol will flash on the display Press any button to stop the alarm e The symbol stop flashing 30 minutes after the rain has finished 7 3 Rain Gauge Display Press RAIN B2 button to view different display The sequence is shown as follow TIME gt Day Month gt Total rainfall status TOTAL gt Last 1 hour rainfall status 1H ie ke J gt Last 24hours rainfall status 24H gt Current rainfallstatus e Total rainfall mode Show the rainfall from the unit started up until you clear to zero or reset When display RAINFALL TOTAL hold RAIN B2 button for 3 seconds to reset the record to zero e 1 hour rainfall 1H mode Show the total rainfall of last hour and will update the status for every 10 minutes e The last 24 hour rainfall Showed the total rainfall of last 24 hours and will update the status for every hour e Current rainfall Showed the current rainfall status and will update automatically If there s no rain in past 30 minutes the counter will reset to zero e SINCE mode Press SINCE B4 button to roll SINCE time day and
2. marks 5 Installation 5 1 Main Unit The main unit can be placed onto any flat surface C3 or wall mounted by the hanging hole C1 at the back of the unit 5 2 Rain sensor The rain sensor should be placed onto outdoor flat surface Note Transmissions between receiver and transmitter can reach up to 30m in open area Open Area there are no interfering obstacles such as buildings trees vehicles high voltage lines etc 6 Manual Time Setting e Hold SETTING B2 button for 3 seconds to enter time setting mode e Press A B1 or W B4 button to adjust the setting and press SETTING button B2 to confirm each setting By keeping the A B1 or W B4 button pressed could accelerate the process and reach the desired value more quickly e The setting sequence is shown as follow 12 24 Format Hour Minute Year Month Day Sequence Month Day MM Inch C F and Rain Alert On Off Note All Setting modes will automatically exit in 15 seconds without any adjustment 7 Rain Gauge 7 1 Reception of outdoor transmitter e The main unit automatically starts receiving transmission from outdoor rain sensor after time setting The symbol flashes when the signal is received successfully e After batteries inserted the rain sensor automatically transmits temperature signal to the main unit e If main unit failed to receive transmission from outdoor rain sensor after the batteries inserted
3. WS 9006 instruction manual User Manual 1 Features 1 1 Rain Gauge 1 2 Time 1 3 Temperature Current 1 Hr 24 Hrs and Total Rainfall Level checking Daily Weekly and Monthly Rainfall History Checking in Bar Chart Format Since Function for Checking the Exact Total Rainfall Rain Sensor with Alarm Time Display with Date Indoor amp Outdoor Temperature Maximum and Minimum temperature Temperature Alert Function 2 Main Unit Appearance Part A LCD A1 Temperature A2 Trend Indicator A3 Time Part B Button B1 4 HISTORY button B2 RAIN SETTING button B3 SEARCH IN OUT TEMP button B4 v SINCE button Part C Structure C1 Wall Mount Hole C2 Battery Cover A4 A5 B5 B6 B7 C3 Rain Alert Rain Gauge Bar Chart ALERT button MAX MIN button RESET button Stand 3 Rain Sensor NAAN D1 Battery Cover 4 Getting Started 4 1 Main Unit e Open battery Cover C1 e Insert 3 x AA size batteries observing polarity and marks e Replace battery compartment cover The product briefly shows all the display segment 4 2 Rain Sensor e Battery compartment of rain sensor is locating on the bottom of unit D1 unscrews the batteries cover to open e Insert 2 x AA batteries observing polarity and
4. e Main Unit Dimensions Rain Sensor Dimensions Battery Requirements SS Base Station indoor 3 x AA batteries Sensors outdoor 2 x AA batteries LIABILITY DISCLAIMER The electrical and electronic wastes contain hazardous substances Disposal of electronic waste in wild country and or in unauthorized grounds strongly damages the environment Please contact your local or and regional authorities to retrieve the addresses of legal dumping grounds with selective collection All electronic instruments must from now on be recycled User shall take an active part in the reuse recycling and recovery of the electrical and electronic waste The unrestricted disposal of electronic waste may do harm on public health and the quality of environment As stated on the gift box and labeled on the product reading the User manual is highly recommended for the benefit of the user This product must however not be thrown in general rubbish collection points The manufacturer and supplier cannot accept any responsibility for any incorrect readings and any consequences that occur should an inaccurate reading take place This product is designed for use in the home only as indication of the temperature This product is not to be used for medical purposes or for public information The specifications of this product may change without prior notice This product is not a toy Keep out of the reach of children No part of this manual may be repr
5. its flash Press A B1 or Y B4 button to select Indoor or Outdoor temperature alert Press ALERT button B5 to confirm the setting Press A B1 or Y B4 button to set the upper 4 and lower limit of the temperature Press ALERT button B5 to confirm the setting ay Press ALERT button B5 to set the Temperature Alert function ON or OFF appears on the LCD if this function is activate Low batteries indication The low battery icon amp will appear when outdoor rain sensor is in low battery status The batteries should be replaced 10 Precautions Use a pin to press the reset button B7 if the Unit does not work properly All Setting Modes will automatically exit in 15 seconds without any adjustment The clock loses its time information when the battery is removed Avoid placing the clock near interference sources metal frames such as computer or TV sets Do not expose it to direct sunlight heavy heat cold high humidity or wet areas Never clean the device using abrasive or corrosive materials or products Abrasive cleaning agents may scratch plastic parts and corrode electronic circuits 11 Specifications Temperature range 10 C to 50 C 14 to 122 F Temperature Units C or F switchable Outdoor Data Transmission distance open 30m 433MHz Temperature range 50 to 70 C 58 to 158 F Rainfall Quantity ee eee e
6. oduced without written authorization of the manufacturer
7. year for checking the since time of each rainfall mode 7 4 Bar Graph Indication and History Daily Weekly and Monthly Rainfall e Press HISTORY B1 button to select daily weekly and monthly rainfall trend e Hold HISTORY B1 button for 3 seconds to view current data today this week or this month then press HISTORY B1 button again to view the history data past 1 6 days weeks or months stored in memory e Hold HISTORY B1 button and SINCE B4 button at the same time for 3 seconds to reset the memory 8 Temperature 8 1 Indoor Outdoor Temperature Press IN OUT TEMP B3 button to select to view Indoor OR Outdoor temperature display 8 2 Maximum Minimum Temperature e Press MAX MIN button B6 to show the maximum recorded Indoor Outdoor Temperature MAX is shown on the LCD e Press MAX MIN button B6 again to show the minimum recorded Indoor Outdoor Temperature MIN is shown on the LCD e Hold MAX MIN button B6 for 3 seconds to clear the recorded maximum and minimum reading 8 3 Outdoor Temperature Trend e The trend pointer A2 displayed on the LCD indicates the trend of the outdoor temperature Indicating the outdoor Indicating the outdoor Indicating the outdoor temp is rising temp is steady temp is falling 8 4 Temperature Alert Function Hold ALERT button B5 for 3 seconds to enter Temperature Alert setting Temperature s dig

Download Pdf Manuals

image

Related Search

Related Contents

Sika®-2  取扱説明書    H2100 Manual REV1-1.eps - Power Washers from Power Washer.US  OS-460 MANUAL DE INSTRUCCIONES  Installationsanleitung für die autorisierte Fachkraft turbotec  VARIABLE SHADE AUTO-DARKENING WELDING HELMET User  White Rodgers 11A79-2 Installation Instructions  REDMOND RMS-4301 hair stylers  NAD Electronics 2700 User's Manual  