Home
LitesF200 Owners 's & Service manual
Contents
1. 5 C or failure on NTC in such event LED will switch to off mode Should any of the above given messages occur for precaution measures the LED will always switch to off mode Halt the unit immediately and refrain from the use of it and promptly contact any authorized service centre Periodical maintenance To ensure the correct LitesF200 s operations we suggest the following periodical maintenance operations Remove dust or any kind of other dirty from the fans and loop holes to ensure the correct air flow Remove dust from lenses using a clean cloth This maintenace will ensure the maximum light efficiency Replace damaged protection screens and lenses when necessary Always handle LitesF200 gently and with care do not drop do not shake do not cause shocks to the unit as it could damage it irremediably Do not touch nor clean the LED as well as the yellow area around it with solvents Device disposal information At the end of its life LitesF200 must be disposed to an Kw appropriate electrical and electronic equipment waste collection centre Eco friendly disposal helps to avoid possible negative impact on the environment and human health and promotes the reuse and or recycling of the materials making up the product Illegal disposal involves administrative sanctions provided by laws enacted Manufacture declines any sort of personal corporate responsibility liability for damages caused by the inadequate use of the product a
2. LInE l Dimmer profile selection l GAMM LinE for linear dimming regulation qUAd qUAd for tungsten lamp emulation Off Boost selection booS off maximum led power at 90 on on maximum led power at 100 AA Display orientation selection PoS VV AA normal VV inverted Standby display activity Off l off display always switched on StbY on display switched off after few seconds of buttons on inactivity only the right side dot will be lighted to indicate DMX availability dEF sl ON Will restore the default factory values TIML h Shows LED life TiMU h Shows HPLed life SoFt Shows Software version DMX Operating Modes Mode Pagina 12 di 8 LitesF200 provides with different DMX operating modes ensuring the ideal use of the DMX universe Shutter strobo 8 16 bit dimmer fan speed and LED frequence are all adjustable Mode a 1ch Ch functon DMX Values 1 dimmer 0 255 Light output O Off 255 Maximum Power mode a 2ch Ch function DMX Values 1 shutter 0 9 off 10 255 Strobe effect from slow to fast 2 dimmer 0 255 Light output O Off 255 Maximum Power mode a 3ch Ch functon DMX Values 1 shutter 0 9 off 10 255 Strobe effect from slow to fast 2 dimmer 0 255 Light output O Off 255 Maximum Power 3 Fan speed 0 24 Fans off 24 255 Fan speed from slow to fast mode a 4ch Ch F
3. LitesF200 Owners s amp Service manual Read this manual totally and carefully follow all the instructions contained File this manual for future use It is essential to read all the information contained to ensure installation service and full operation of the LitesF200 All operations must be accomplished handled and carried out by qualified personnel only Not complying with given notice will void warranty and will free manufufacturer from any liability responsability http www ilites eu Pagina 2 di 8 Unpacking Unpack the carton and gently remove LitesF200 from the box Ensure LitesF200 received is integer from origin in all its components In the event the LitesF200 shows any damage do not use it and contact immediately your transporter as well as your seller Items in the carton consist of LitesF200 luminaire Colour frame Blue Neutrik PowerCon connector This owner s and service manual Safety information for the use of the LitesF200 as well as its periodical maintenance LitesF200 is for professional use only and NEVER for domestic use therefore refrain from this latter utilisation Users must scrupulously comply with information that follows any other use in contrast will void warranty and will free the manufacturer of any sort of responsibility and liability Never use LitesF200 on any flammable surfaces Minimum distance from any flammable source is of 0 25m Minimum throw distan
4. ce from illuminated surface 0 5m Installation of the unit s must be secured with adequate clamps safety cords nuts and bolts to bear the weight of the whole unit s Always Power LitesF200 to safety circuit breakers LitesF200 must NOTand CAN NOT be operated via Phase Control Dimmer Install LitesF200 in ventilated ambient which temperature must not trespass 35 C Some outer parts of the LitesF200 can reach temperatures of up to 60C when in operation LitesF200 must be fitted with protection shields Lenses Onno account directly or indirectly LED must be touched Always disconnet power always double check that power is off before any Service Operation of the unit LitesF200 is rated Class I Earth connection is MANDATORY An essential and periodically throughout cleaning of the LitesF200 is recommended This practice avoids that layers of dust and other impurities jeopardise and reduce the correct operation of the unit Lenses must be cleaned to remove layers of dust that may impede and or reduce the passage of the light through the lenses The correct and periodically maintenance keeps also fans and vents clean to keep the LitesF200 in its best performance conditions Never touch the Yellow core of the LED Pagina 3 di 8 both directly or indirectly nor use solvents that can damage the LED irremediably Protection shields if battered must be replaced with new ones Lenses CE APPROVALS The LitesF200 meet
5. g yoke to adjust and set unit to position Beam angle 18 60 Working position 90 90 on vertical axe Protection rating IP 20 DMX 512 RDM Protocols wireless on request Neutrik powercon IN amp OUT connectors Neutrik XRL5 IN amp OUT signal connectors 4 digit display Manual operation via 4 digit display Idle fan mode for totally silent use of the unit Adjustable LED frequency Selection of two LED dimming curves Comply with C Dimensions see figure Pagina 5 di 8 Pagina 6 di 8 Lites200F installation Lirtes200F is delivered with a robust yoke which hosts 3 x 12 mm mounting holes The use of an adequate G clamp to sustain at least twice the weight of the Lites200F Lites200F weighs 7 9 kg and or M10 screw is mandatory The use of safety chain s to sustain twice the weight of the Lites200F is also mandatory the safety chain adds more protections to users and third parties Eye lid for the safety chain is provided on the LitesF200 see Fig The Lites200F yoke revolves on 360 on the projectors axis Lites200F can be installed 90 on the vertical axis see Fig Best Lites200F s perfomrances are achiieved if unit is installed as shown in the illust
6. n the axis of the luminaire When correct position is set to position secure it by tightneing the provided side knob Beam adjusment is achieved via rear Helicoidal screw Turn clockwise to narrow beam conversely beam widens ZOOM Connection to mains WARNING Installation s must be accomplished handled and carried out by qualified personnel only and must comply with all norms in force in the installation s country LitesF200 is supplied with a free Blue Neutrik PowerCon plug that must be wired using a 3x1 5mm lead additional specifications include Operating Voltage 300 500V Test Voltage 2KV Operating Temperature 10 C 100 C Connect blue wire to N terminal brown wire to L terminal and Yellow Green wire to sarth terminal see also illustration fig Ensure connections to safety circuit breaker at all times Daisy chain of up to maximum 8 units if connected to 230VAC Daisy chain of up to maximum 4 units when connected to 110VAC Maximum daisy chain length 25m WARNING LitesF200 CANNOT be powered by using an angle phase dimmer pack Pagina 10 di 8 ET ls N POWER OUT On L Ex Signal Control Connection LitesF200 can be operated via either DMX512A and or RDM ready For dasy chain connection use a 2 x 0 5 Mm size lead wire plus shield Connect Pin 1 to ground 2 data while Pin 3 data Pins 4 amp 5 are not connected Ensure that DMX wires and shield do not interfere no
7. r touch each other as well as they must not touch interfere with the body of the unit DMX connectors are not provided Important note when DMX is available a red dot will illuminate on the left hand of the display When red dot is off no DMX signal is available WARNING Before powering LitesF200 ensure that all installation s procedure s have s been properly set and accomplished XLR5 connection Le Descrip ads tion 1 GND 2 DMX 3 DMX 4 NC Projector mode settings 5 NC Pagina 11 di 8 When LitesF200 is powered setup display will show the software release version The UP DOWN ENTER and ESC buttons will allow the operations of the LitesF200 menu UP and DOWN buttons allow to scan menu options ENTER button allow to select The ESC button is to retun to the previous menu or to quit the previous setting Menu items Displayed Allowed or i displayed values Mode Addr 001 510 DMX address as of 1 to 510 1 ch 2 ch Mode 3 ch DMX Operating mode see next page 4 ch 5 ch Man 0 255 Manual light output adjustment This is possible even if no DMX is present Adjusted value will be stored on the internal permanent memory drUt GC Shows driver operating temperature LEdt LC Show led operating temperature PUM 0 100 Shows current led power 0 100 FAST SMOO MED DMX data Speed adjustment SLOW
8. rations that follows never install LitesF200 upsidedown illustrations that folllows show installation positions that must be avoided Incorrect installation s can immediately or in short long terms jeopardise the correct operaton of the LitesF200 Incorrect installations may voide the warranty of the unit Pagina 7 di 8 AVOID INCORRECT INSTALLATIONS AS ILLUSTRATED Pagina 8 di 8 Installations of the accessories LitesF200 is delvered with a standard 195x185mm colour frame standard colour frame 185x185 can als be used The LED source used on LitesF200 allows the use of colour filters that cannot be used with high wattage tungstene lamps which would impair colour filters Optional and standard 185x185 mm 4 leaf barndoor can also be installed in the provided gates Ensure that accessories when installed on the LitesF200 are securely fitted in the gates and that are triggered and secured by the spring lock provided see figure Beam adustment Pagina 9 di 8 Lites200F can revolve 90 upwards and 90 donwwards o
9. s EMC 89 336 CEE 92 31 CEE BT72 23 CEE 98 68 CEE requirements The LitesF200 complies with EN50419 Rohs and 2002 96 EC WEEE norms WARRANTY A 12 month warranty is granted on the LitesF200 from its purchase s date Warranty covers fabrication defects only unit will not be replaced but will be 100 fixed Warranty is immediately voided if the LitesF200 has not been handled by qualified personnel Any improper and unauthorised use such modification s or misapplication of the unit will also void the warranty of the product s Silver colour label showing technical data and serial number if removed or if data are impaired to render details illegible will immediately void the warranty Pagina 4 di 8 Technical specifications Power Supply 100 240V 50 60Hz autosetting Maximum power consumption 200W Citizen CLL050 CLL052 cos 0 98 Maximum power consumption 140W Bridgelux BXRA Vero cos 0 98 Stand by power consumption 5W LED Colour temperatues and CRI ASK INFORMATION at info ilites eu Fresnel Lens 150mm Colour frame dimensions 195x185 mm the use of standard 185x185mm colour frame is totally acccettable Aluminium die caste body to maximize heat dissipation Operating temperature range 15 C 35 C Maxium temperature on the LitesF200 60 C Weight of the unit Kg 6 9 Worm gear beam adjustment on standard Lites200F Automatic zoom on LitesF200Zoom Rear handle for good grip of unit side lock on mountin
10. s well as if unqualified personnel have nandled the product Not complying with security norms periodical maintenance as Pagina 15 di 8 axpressed in the owner s service manual will also totally free personal corporate responsibility liability Text wordings drawings specifications modifications and other changes of this manual may apply anytime without notice The specifications are not binding Lites F 200 White 04 11 2013 rev 01 Pagina 16 di 8
11. unction DMX Values 1 shutter 0 9 off 10 255 Strobe effect from slow to fast 2 dimmer 0 255 Light output O Off 255 Maximum Power 3 Fans 0 24 Fans off 24 255 Fan adjustement from minium to max value 4 LED 0 24 PWM Frequency 5 1KHz Frequency 25 49 PWM Frequency 5 2KHz Modulation 50 74 PWM Frequency 5 3KHz 75 99 PWM Frequency 5 4KHz 100 124 PWM Frequency 5 5KHz 125 149 PWM Frequency 5 6KHz 150 174 PWM Frequency 5 7KHz 175 199 PWM Frequency 5 8KHz 200 224 PWM Frequency 6KHz 225 255 PWM Frequency 610Hz mode a 5ch Ch function DMX Values Pagina 13 di 8 shutter 0 9 off 10 255 Strobe effect from slow to fast 2 dimmer 0 255 Light output O Off 255 Maximum Power Fine 0 255 0 255 fine dimmer adjustment Dimmer Fans 0 24 Fans off 24 255 Fan adjustement from minium to max value LED 0 24 PWM Frequency 5 1KHz Frequency 25 49 PWM Frequency 5 2KHz Modulation 50 74 PWM Frequency 5 3KHz flickering 75 99 PWM Frequency 5 4KHz 100 124 PWM Frequency 5 5KHz 125 149 PWM Frequency 5 6KHz 150 174 PWM Frequency 5 7KHz 175 199 PWM Frequency 5 8KHz 200 224 PWM Frequency 6KHz 225 255 PWM Frequency 610Hz Pagina 14 di 8 Error messages In case of malfunction the following messages may be shown LED ERROR sympthon of a possible short circuit on LED driver TEMPERATURE ERRor sympthon that sensors have measured temperature below 1
Download Pdf Manuals
Related Search
Related Contents
FOIA Processing in the Presidential Electronic Records Pilot MÖJLIG Domino-Gaskochfeld, 2 Brenner Betriebsanleitung $0$=21( Bordrechner - Ersatzteile 13 - Buschkamp Télécharger l`ouvrage "Alterner pour Apprendre" Descargar Macom 209 Copyright © All rights reserved.
Failed to retrieve file