CBX100 LT Installation Manual
Contents
1. Figure 1 Overall Dimensions ELECTRICAL CONNECTIONS AND SETUP The following figure shows a typical layout PWR PS I O Main Interface Scanner Auxiliary Interface Scanner CBX100 LT Reading Device Configuration PC Figure 2 System Layout The dotted line in the figure refers to an optional temporary hardware configuration in which a portable PC can be quickly connected to the CBX100 LT and consequently to the reading device auxiliary interface through the internal 9 pin connector This allows monitoring of the data transmitted by the reading device or configuration through the utility program see the reading device Installation Manual for more details The reading device auxiliary interface signals are also available on the internal spring clamp connectors After making system cabling and switch settings connect the reading device to the 25 pin connector on the CBX100 LT housing Switch ON the CBX100 LT power switch see Figure 3 The Power LED turns on blue when the power connection has the correct polarity The Power LED turns on red in case of wrong polarity After system functioning has been verified close the CBX100 LT using the 2 cover screws POWER SUPPLY Power is supplied to the CBX100 LT through the Vdc and GND pins provided on the spring clamp connector The power switch see Figure 3 switches the power supply ON or OFF for both the CBX100 LT and the connected read
2. ID NET Network Network Cable Shield a ___RS232_ RS485FD RS485HD Interface Lo a Main Cs rs a SS The input power signals Vdc GND and Earth as well as the network signals REF ID ID and Shield are repeated to facilitate system cabling In this way the power and network busses can enter and exit the CBX100 LT from different spring clamps but be physically connected together POWER SOURCE JUMPER SETTINGS For most applications input power is provided through the dedicated spring clamp connectors inside the CBX100 LT However CBX100 LT may accept power from the connected reading device through the 25 pin connector This is useful for example to pass power to connected accessories such as Encoder and Presence Sensor from DX8200A VAC models or 6K 8K scanners powered directly through the network See the relative reading device Reference Manual for details To power CBX100 LT from the reading device the power source jumper must be placed in the power from device position as indicated in Figure 5 power from power from device clamps default Figure 5 Power Source Jumper Settings SHIELD TO PROTECTION EARTH JUMPER SETTINGS The network cable shield Shield can be connected to Earth Ground Earth either directly or through a filter circuit If the jumper is left open the network cable shield Shield is floating Earth floating Filtered Earth default Figure 6 Shield to Protection Earth J
3. Search through the links to arrive at your product page where you can download specific Manuals and Software amp Utilities e SERVICES amp SUPPORT Datalogic Services Warranty Extensions and Maintenance Agreements Authorised Repair Centres e CONTACT US E mail form and listing of Datalogic Subsidiaries CE COMPLIANCE Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures SDATALOGIC DECLARATION OF CONFORMITY CE Datalogic Automation S r l Via S Vitalino 13 40012 Lippo di Calderara Bologna Italy dichiara che declares that the d clare que le bescheinigt da das Ger t declare que el e tutti i suoi modelli and all its models et tous ses mod les und seine Modelle y todos sus modelos CBX100 LT connection box compact low temperature sono conformi alle Direttive del Consiglio Europeo sottoelencate are in conformity with the requirements of the European Council Directives listed below sont conformes aux sp cifications des Directives de l Union Europ enne ci dessous der nachstehend angef hrten Direktiven des Europ ischen Rats cumple con los requisitos de las Directivas del Consejo Europeo seg n la lista siguiente 89 336 EEC EMC Directive e 92 31 EEC 93 68 EEC emendamenti successivi and further amendments et ses successifs amendements und spateren Abanderungen y succe
4. DATALOGIC CBX100 LT Installation Manual The CBX100 LT is a connection box which can be used as an accessory to facilitate system connections for installation and device replacement of several Datalogic family reading devices specifically designed to be used in low temperature applications System cabling is made through spring clamp terminal blocks inside the CBX100 LT while the reading device is connected to the CBX100 LT through a 25 pin connector on the housing A 9 pin connector placed inside the CBX100 LT facilitates connection between an external PC and the auxiliary serial interface of the reading device for configuration or data monitoring GENERAL VIEW CBX100 LT Figure A D Indicator LEDs 2 Cover Screws 2 3 Compression Connectors 4 4 25 pin Device Connector Figure B 1 Power switch ON OFF Auxiliary Port Connector 3 Mounting Holes 2 4 ID NET Termination Resistance Switch Indicator LEDs 6 Spring Clamp Terminal Blocks T RS485 Termination Resistance Switch Power Source Selector Shield to Protection Earth Selector Chassis Grounding Selector SAFETY PRECAUTIONS ATTENTION READ THIS INFORMATION BEFORE INSTALLING THE PRODUCT POWER SUPPLY This product is intended to be installed by Qualified Personnel only This device is intended to be supplied by a UL Listed NEC Class 2 power source Total power consumption is given by adding the CBX100 LT power con
5. ation of the connected reading device TECHNICAL FEATURES ELECTRICAL FEATURES Supply Voltage 10 to 30 Vdc Consumption 0 5 0 3A Limited Current Consumption 2 5 A Max CBX reading device consumption see related manual USER INTERFACE LED Indicators Power On Polarity Error blue red Trigger yellow IN2 green OUT1 yellow OUT2 green PHYSICAL FEATURES Mechanical Dimensions 138 x 128 x 62 mm 5 4 x 5 x 2 4 in ENVIRONMENTAL FEATURES about 380 g 13 40 oz Operating Temperature 35 to 50 C 31 to 122 F 14 mm 2 to 10 Hz 1 5 mm 13 to 55 Hz 2 g 70 to 200 Hz Shock Resistance 30 g 11 ms EN 60068 2 27 3 shocks on each axis Protection Class IP65 EN 60529 when compression connectors and reading device are correctly connected Storage Temperature Humidity max Vibration Resistance EN 60068 2 6 2 hours on each axis The features given are typical at a 25 C ambient temperature if not otherwise indicated for further details about minimum maximum supply voltage refer to the manual of the connected reading device since the minimum supply voltage required may be gt 10 installation must be made at a temperature not lower than 20 C SERVICES AND SUPPORT Datalogic provides several services as well as technical support through its website Log on to www automation datalogic com and click on the links indicated for further information including e PRODUCTS
6. er and input output signals e Prepare the individual wires of the system cables by stripping the insulation back approximately 1 cm e Using a device such as a screwdriver push down on the lever directly next to the clamp see Figure 4 e Insert the wire into the clamp and release the lever The wire will now be held in the spring clamp 5 Tighten the compression connector nuts so that the internal glands seal around the cables Figure 4 System Cable Connections Flexible stranded wire should be used and must meet the following specifications All positions 24 16 AWG 0 2 1 5 mm The CBX100 LT spring clamp connector pinouts are indicated in the Pinout table Refer to the reading device Installation Manual for signal details pit Power Supply Input Voltage Sct Power Supply Input Voltage Protection Earth Ground Power Source External Trigger External MA External Trigger A polarity insensitive mO AB Input Mo Power Reference External Trigger I V_ Power Source Inputs Generic IZA Input 2 A polarity insensitive Input 12B Input 2 B polarity insensitive Power Reference Inputs V Power Source Outputs Power Reference Outputs O1 Output 1 eu e i Output 1 Output 2 Output 2 Auxiliar Auxiliary Interface TX Ti A RX Auxiliary Interface RX SGND D V 1A 1B V V Auxiliary Interface Reference Network Reference ID NET Network ID
7. ing device The power switch does not control power to the Vdc GND V V spring clamps therefore any devices connected to these signals i e external trigger encoder etc are live and are not protected from polarity inversion Disconnect the power supply when AUTION eres working inside the CBX100 LT CBX100 POWER SUPPLY V 10 30 Vdc GND Earth Ground Figure 3 Power Switch ON OFF Positions and Connections Vdc is electrically connected to V just as GND is electrically connected to V This is useful for supplying external trigger inputs and outputs from the CBX100 LT power source however V and V signals should not be used as power supply inputs to the CBX100 LT The power supply must be between 10 and 30 Vdc only To avoid electromagnetic interference Connect CBX100 LT Protection Earth Earth to a good earth ground Connect the reading device chassis to earth ground through the jumper default setting see Figure 7 Connect the Network Cable Shield Shield to Filtered Earth through the jumper default setting see Figure 6 SYSTEM WIRING The connection and wiring procedure for CBX100 LT is described as follows 1 Open the CBX100 LT by unscrewing the 2 cover screws 2 Verify that the CBX100 LT power switch is off see Figure 3 3 Unscrew the compression connectors and pass all the system cables through them into the CBX100 LT housing 4 To connect the pow
8. mination resistor for ID NET network applications In ID NET network applications the termination resistor must be enabled ONLY on the first and last devices of the chain On all the other devices this CAUTION resistor MUST NOT be enabled OFF RS485 HD A Figure 9 RS485 HD Termination Resistance Switch The RS485 HD termination resistance switch enables or disables the insertion of the bus termination resistor for RS485 Half Duplex Multidrop applications In Multiplexer applications the termination resistor must be enabled ONLY on the last device of the chain the farthest away from the Multiplexer assuming the Multiplexer is the first device of the chain On all the other devices this resistor MUST NOT be enabled OFF CAUTION INDICATOR LEDS blue red yellow Figure 10 Indicator LEDs There are five Indicator LEDs which signal power and O activity and are visible from the CBX100 LT outside cover The Power LED is blue when power is correctly applied to the CBX100 LT and the power switch is turned on This LED is red if power polarity is incorrect In this case the connected reading device and optional Backup Module are protected If external I O devices are powered through CBX100 LT connected to V V they are not protected from polarity inversion CAUTION The remaining four LEDs signal activity on the relative I O lines Their meaning depends on the software configur
9. sivas enmiendas Basate sulle legislazioni degli Stati membri in relazione alla compatibilit elettromagnetica ed alla sicurezza dei prodotti On the approximation of the laws of Member States relating to electromagnetic compatibility and product safety Bas e sur la l gislation des Etats membres relative a la compatibilit lectromagn tique et a la s curit des produits Uber die Ann herung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Vertraglichkeit und Produktsicherheit entsprechen Basado en la aproximaci n de las leyes de los Pa ses Miembros respecto a la compatibilidad electromagn tica y las Medidas de seguridad relativas al producto Questa dichiarazione basata sulla conformit dei prodotti alle norme seguenti This declaration is based upon compliance of the products to the following standards Cette d claration repose sur la conformit des produits aux normes suivantes Diese Erkl rung basiert darauf daf das Produkt den folgenden Normen entspricht Esta declaraci n se basa en el cumplimiento de los productos con las siguientes normas EN 55022 Class A ITE September 1998 INFORMATION TECHNOLOGY EQUIPMENT RADIO DISTURBANCE CHARACTERISTICS LIMITS AND METHODS OF MEASUREMENTS EN 61000 6 2 September 2005 ELECTROMAGNETIC COMPATIBILITY EMC PART 6 2 GENERIC STANDARDS IMMUNITY FOR INDUSTRIAL ENVIRONMENTS Lippo di Calderara January 29th 2008 Lorenzo Girotti Product amp Process Qualit
10. sumption to that of all the devices powered through the CBX100 LT reading device P S I O Refer to the manual of the connected devices for details about minimum maximum supply voltage and power consumption CAUTION Each CBX100 LT supports only 1 single reading device system accessories OPENING THE CBX100 LT To install the CBX100 LT or during normal maintenance it is necessary to open it by unscrewing the two cover screws The CBX100 LT must be disconnected from the power supply during this operation CAUTION one ies must be made at a temperature not lower than MECHANICAL INSTALLATION CBX100 LT can be mounted to various wooden or plastic surfaces using the two self threading screws 3 9 x 45 mm and washers provided in the package Mounting to other surfaces such as concrete walls or metallic panels requires user supplied parts Screws screw anchors nuts etc A mounting template is included in the package to facilitate hole drilling alignment CBX100 LT can also be mounted to a DIN rail or a Bosch Frame using the following mounting accessories BA100 93ACC1821 BA200 93ACC1822 The diagram below gives the overall dimensions of the CBX100 LT and shows the two mounting through holes
11. umper Settings CHASSIS GROUNDING JUMPER SETTINGS The reading device chassis grounding method can be selected by positioning a jumper see Figure 7 In this way the reading device chassis can be connected to earth ground only if pin Earth is connected to a good earth ground For all reading devices except 6K 8K the chassis can alternatively be connected to the power supply ground signal GND or it can be left floating but in this case the jumper must be removed For 6K or 8K scanners the chassis is internally connected to GND All Reading Devices except 6K 8K to GND floating to Earth default 6K 8K Family Scanners The scanner chassis is ofo oO internally connected to GND Ke to Earth default Figure 7 Chassis Grounding 9 PIN READING DEVICE AUXILIARY SERIAL INTERFACE The reading device auxiliary serial interface available on the internal CBX100 LT 9 pin connector can be used either for configuration or for data monitoring Connections can be made to a PC or Laptop using a straight through cable or a USB RS232 converter The details of the connector pins are indicated in the following table CBX100 LT 9 pin D Sub Female Connector Pinout Auxiliary RS232 SGND Auxiliary Reference Ground 1 4 67 89 O SNC NETWORK BUS TERMINATION ID NET Figure 8 ID NET Termination Resistance Switch The ID NET termination resistance switch enables or disables the insertion of the bus ter
12. y Manager ae JAM 821001540
Download Pdf Manuals
Related Search
Related Contents
Tanaka ECS-3500 User's Manual Ford 2008 E-150 Automobile User Manual Western Digital 4779 705004 Switch User Manual User Manual Cisco Systems 1080P12X Webcam User Manual Operation & Installation Manual 01/11/2012 Le Guide du Partenariat Mode d`emploi : annexe juridique au RGT Copyright © All rights reserved.