R&S®EMC32/AMS32 EMC Measurement

image

Contents

1. AoGM Installation Manual 1144 5428 42 10 27 R amp S EMC32 AMS32 Using the iKey Merge Tool 3 The upgrade will be started by pressing the Upgrade to V9 button A new window opens where the license code from the license upgrade document U9 has to be entered Take care to verify the selected Base License Type Enter License Key Code al x Base License Type S SNAS C EMC32 EB EMC32 5 C AMS32 Please enter your License Code from the License Key List 1 2 3 4 5 6 7 8 ci OD 73DA B254 0658 8874 8388 sb OC faaoo Close 4 While reprogramming the iKey the actual status is shown in the information window When the programming is finished successfully the U9 option is displayed in the left window and the tool can be closed with the Exit button Rohde amp Schwarz EMC32 iKey Merge Tool 9 0 zt p Serial Number Mode Serial Number Serial S N 100333 Mode EMS Not available ra available m More More Production Date 2012 01 16 Not avalilable Mayr ME2A Demo for U9 Upgrade p Comment Comment iKey ready No iKey found Option Description EMC32 U95 Upgrade EMI EMS section to V3 A No iKey found KA a Choose iKey Choose iKey uriase iKey Number 0121061F000024FE B ure iKey Number LZ Save Changes ta Keys Exit 5 Please keep your upgrade license documen
2. n J t m Installation Manual 1144 5428 42 10 14 R amp S EMC32 AMS32 Installing R amp S EMC32 AMS32 ss n H nm If you add a new device to the R amp S EMC32 AMS32 device list which requires a o VXI driver you may optionally start the Driver Installer Tool in R amp S EMC32 AMS32 from the driver missing warning dialog If you run an update of R amp S EMC32 AMS32 it may be required to update the drivers as well Thus you see the new version of the driver delivered with this R amp S EMC32 AMS32 release in the appropriate column of the driver installer tool Some driver may need a Windows restart after installation is completed In this case you either should postpone the Windows restart action or you must resume the driver installation after this driver manually m J P SS nm Installation Manual 1144 5428 42 10 15 R amp S EMC32 AMS32 Installing R amp S EMC32 AMS32 co ueg 3 3 3 Network Installation Tips Typically the installation of the R amp S EMC32 AMS32 application software should be done in the Program Files folder of your local hard disk But it is possible to place the R amp S EMC32 AMS32 data folder on a network
3. 1 Click the Start button on your desktop 2 Select Programs gt Rohde amp Schwarz gt EMC32 gt EMC32 or Programs gt Rohde amp Schwarz gt AMS32 gt AMS32 Selection of the User Interface Language The user interface language of the R amp S EMC32 AMS32 can be changed in the R amp S EMC32 AMS32 via the dialog Extras gt Language The new language will be activated after a re start of EMC32 AMS32 Installation Manual 1144 5428 42 10 18 R amp S EMC32 AMS32 EMC32 Configuration 9 EMC32 Configuration Before running a measurement with EMC32 the software must be adapted to your system i e you must tell the application which measurement devices are available through which interfaces these devices may be addressed how the devices are connected with each other and how a test using this devices should be performed A Configuration Wizard is available in EMC32 which determines the measurement categories and the measurement instruments available in the system through user queries Using this information the configuration wizard creates a standard configuration for your system Correction tables and test templates will also be copied into the appropriate directories After this step EMC32 is ready to run the first demo measurement Before the first start of a real EUT measurement the appropriate calibration data for the antennas transducers and the signal paths have to be entered or calibrated for more information on this
4. EMC32 AMS32 Moving of important calibration or configuration files may also prevent other tests from being opened or started For detailed information on the file structure of R amp S EMC32 AMS32 refer to the appropriate section of the EMC32 AMS32 online help m X bui dg e Installation Manual 1144 5428 42 10 16 R amp S EMC32 AMS32 Installing R amp S EMC32 AMS32 ss GcOo n n n 3 4 iKey Software Protection R amp S EMC32 AMS32 is copy protected by a hardlock iKey that contains the license information Before running R amp S EMC32 AMS32 with devices the iKey driver must be installed and the iKey itself be connected to the PC The installation of the iKey software is easily started via the R amp S Driver Installer Tool refer to the previous chapters Follow the instructions in the setup program You may need to restart your computer or connect the iKey to a free USB port of your PC during the installation You can check the correct functionality of the iKey as follows After restarting the computer a utility program appears in the task list called iKey Token Utility with which you can check whether the iKey can be detected by the driver By double clicking on that icon the program is started and the following dialog appears on the screen If the serial number of the iKey is dis
5. not use the digit grouping symbol use space character instead Virus scan programs with an active real time scanning process may decrease the performance of R amp S EMC32 AMS32 If possible deactivate this process or exclude R amp S EMC32 AMS32 files from this process During the installation R amp S EMC32 AMS32 requires full access to the Windows registry key HKEY LOCAL MACHINE SoftwarelRohde amp Schwarz Installation Manual 1144 5428 42 10 31 R amp S EMC32 AMS32 Index Index A Administration ee 8 AMS32 Configuration ss see eee eee eee eee 21 AUtostart Tu 10 C CD Installation eee 10 Configuration Standard Data eeeeeeeeeenenee 21 Wizard mejeeesseecavaasesesesnanseadaesesssesnanesansasesenne 19 CONVENTIONS e e ce ee eeeeceeeeeesseaneeeeeeeeenees 3 D Data BACKUP 16 SIM 8 Data Folder aie icr turres teenua 12 E EMC32 Configuration ssessssss 19 EMC32 Product Cross Reference Table 22 l EN EE 17 Merge TOO uventet Ene 27 Installation DIVETS urnegraver 14 gell 1 1 RERO 8 Fundamentals eese 8 Hardware e 17 Network cere eerte eene ttn nn 16 GE agoni oaoa T anaie ah oiaoi 9 L Rer eL ettet teret e estes keen 18 N Newsletter Service eee eee 6 O Online Help etr tenen 18 S Starting the program sss 18 SUP POM EE 5 System Requirement e
6. this issue the setup program allows to define another location for the R amp S EMC32 AMS32 data folder for example C ProgramData EMC32 or D EMC32 for installations on Windows 7 Vista the data folder is set to the common application data folder by default For all R amp S EMC32 AMS32 users the computer administrator must set full read and write access to this folder to all its subfolders and to all R amp S EMC32 AMS32 shortcuts 3 2 2 Data Security and User Administration For ensuring the data security of the EMC data files the file protection functions of the Windows operating system have to be used security section in the Windows file or folder properties dialog User administration features inside R amp S EMC32 AMS32 are not designed to ensure data security and can therefore only be used to prevent Standard Users from modifying essential settings inside the R amp S EMC32 AMS32 for example the device configuration Installation Manual 1144 5428 42 10 co R amp S EMC32 AMS32 Installing R amp S EMC32 AMS32 T H m ung In case R amp S EMC32 AMS32 is only operated by few users of comparable knowledge level it may not be required to use file security features of the operating system Here the user has to decide if a user log in and user list is required and if test data of different users shall be kept in different directories For further infor
7. will resume the installation process afterwards Please note that for each R amp S EMC32 AMS32 application or option an iKey must be available Otherwise the software can only be operated in demo mode which means that no devices can be addressed and measurements are only performed in a simulation mode For demonstration purposes you can use this feature of the software m M v nt Installation Manual 1144 5428 42 10 13 R amp S EMC32 AMS32 Installing R amp S EMC32 AMS32 HM un 3 3 2 Driver Installer Tool The R S Driver Installer Tool is a utility program which allows to install all required USB VXI plug amp play and other device drivers in a sequence The Driver Installer Tool may be started either immediately after the R amp S EMC32 AMS32 installation or via the entry in the Rohde amp Schwarz program group The driver installer tool runs the setup programs from the R amp S EMC32 AMS32 CD ROM root folder which may have to be adapted if the CD ROM image location was changed after the initial installation Before running the installation ticks the device drivers which are required for the devices in your system For further information on the supported devices by R amp S EMC32 AMS32 and the required drivers please refer to the list of supported devices in the R amp S EMC32 AMS32 CD RO
8. your hard drive Install Program Files to C Program Files Rohde Schwarz EMC32 Change InstallShield 8 Click on the Next gt button and change the path for the installation of the EMC32 AMS32 data refer to Installation Fundamentals for further information In case of an upgrade use the path where your R amp S EMC32 AMS32 data is located JE EMC32 InstallShield Wizard Database Folder Click Next to install to this folder or dick Change to install to a different fo Install EMC32 data folder to C ProgramData EMC32 If you are upgrading an existing EMC32 installation the data path must direct to the root folder containing the CONFIGURATION folder InstallShield BE Installation Manual 1144 5428 42 10 11 R amp S EMC32 AMS32 Installing R amp S EMC32 AMS32 e When installing on Microsoft Windows 7 the default data folder path will be set to the system common application data path for example C ProgramData EMC32 on Windows 7 By default this folder is not shown in the Windows 7 file explorer so changing o the path to C EMC32 may be useful Take also in mind that this path later contains all your configuration and test result data for backup purpose 9 Click on the Next button and start the installation process 10 On a successful installation you will receive a confirmation which you can close by clicking on the Finish button 11 Alternatively the installation process m
9. 32 Data Backup sese 16 3 4 iKey Software Protection ssninecisinnortausss ntosadiinraierneareueninnnbimateuainninraininloie 17 d Starting the program sc cesesssess esse eee eee cesses esec eee esse nnmnnn nnna 18 5 EMC32 Gonfigurallonh e eeeor etta eers eroi nennen enean en 19 6 AMS32 Configuration rrrnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 21 7 Upgrading EMC32 AMS32 eenn eenn 22 7 1 EMC32 Product Cross Reference Table esss 22 7 2 Migrate R amp S EMC32 AMS32 Data Folders 23 7 3 Upgrade Procedure uscire pcr vag cia Ka E C NER Rand IRI RO DER CFI resen 25 7 3 1 Base License iKey Upgrade eee esse 25 7 3 2 Software Upgrade Procedure sss sees 25 Installation Manual 1144 5428 42 10 1 R amp S EMC32 AMS32 Table of Contents 8 Uninstalling R amp S EMC32 AMS32 26 9 Using the iKey Merge Tool 27 9 1 Upgrade of the Base License to V9 esee 27 9 2 Merge Option iKey to a Base License iKey 29 Ucet gr repu 31 lis A 32 he J M V H BN Installation Manual 1144 5428 42 10 2 R amp S EMC32 AMS32 Conventio
10. 8 42 10 26 R amp S EMC32 AMS32 Using the iKey Merge Tool 9 Using the iKey Merge Tool 9 1 Upgrade of the Base License to V9 For upgrading your base license to version 9 you need the base license iKey e g EMC32 EB the upgrade license document with the license code e g EMC32 U9E and the EMC32 AMS32 software V9 installed on your PC Do not remove an iKey or shutdown your PC when the iKey Merge Tool is running e since the contents of the iKeys may be lost Shut down any running programs 1 Start the iKey Merge Tool from the EMC32 program group connect only your base license iKey and press the Load iKeys button to read data of your connected iKey p Serial Number Mod Serial Number le Mode Not available na available Not available E available More More Not avalilable Not avallable 2 If the currently connected iKey supports an upgrade to V9 the Upgrade to V9 button will be shown p Serial Number Mode p Serial Number Mode Serial S N 100333 Mode EMS Not available Not avaiable More p More Production Date 2012 01 18 Not avalllable Mayr ME2A Demo for U9 Upgrade r Comment r Comment iKey ready No iKey found Description No iKey found Choose iKey Unge iKey Number 0121061F000024FE x Upgrade to V9 Load Keys J
11. C32 EB EMC32 S or AMS32 with the appropriate upgrade options EMC32 U9E EMC32 U9S or AMS32 U9 Please contact your sales representative for further information on the upgrade license T 1 EMC32 Product Cross Reference Table The following cross reference table shows what EMC32 AMS32 V9 application s and option s you must install to cover the functionality of a previous product version EMC32 AMS32 Vx Product EMC32 AMS32 V9 Product Options EMS32 S EMESeS EMC32 U9S EMC32 EB EMIS EE EMC32 U9E EMC32 EB EMC32 K10 EMC32 U9E EMC32 E Plus EMC32 E EMC32 EB EMC32 K10 EMC32 S EMC32 K1 EMC32 U9E EMC32 U9S EMC32 K7 optional EMC32 A EMC32 A EMC32 EB EMC32 K10 EMC32 C EMC32 S EMC32 C EMC32 U9E EMC32 U9S EMC32 K7 optional AMS32 ANUS AMS32 U9 m M SS Installation Manual 1144 5428 42 10 22 R amp S EMC32 AMS32 Upgrading EMC32 AMS32 7 2 Migrate R amp S EMC32 AMS32 Data Folders Since EMC32 AMS32 allows to fully separating the executable and data folder you may want to migrate the data folders to the new EMC32 AMS32 data root folder which has been defined during the setup refer to the chapter refer to the chapter EMC32 AMS32 V9 0 requires an upgrade license for each main application EMI EMS AMS Thus do not install V9 0 on your te
12. M Auto Start program on the R amp S EMC32 AMS32 CD ROM Z R amp S Driver Installer Tool EJ Initial EMC32 5M532 Installation on PC C Update EMC32 4MS32 Drivers Driver Setup Programs Source Folder Folder C Users GRATZL_R Desktop DISK1 Driver Selection Table Dives Description Version Installed Do Install 1 EE TET 2 National Instruments GPIB Driver with NI VISA 2 73 vi 3 R amp S NRP NRP2 Power Meter VXIplug amp play Driver 2 3 0 vi 4 R amp S NRP Z x RF Probe USB Driver Toolkit 2 1 14 n a vi 5 R amp S NAP Zxx RF Probe VXIplug amp play Driver 2 1 7 vi B R amp S SMA10D RF Generator VXIplug amp play Driver 2 10 0 vi 7 R amp S SMB1004 SMC1004 Generator VXIplug amp play Driver 2 10 0 vi 8 R amp S SMBV10DA SMU2004 SMJ1004 VxIplug amp play Driver 20 1 vi R amp S SMF1004 RF Generator VXIplug amp play Driver 2 15 0 vi R amp S AM 300 Arbitrary Waveform Generator USB Driver 1 8 1 vi R amp S UPP200 400 800 Audio Analyzer VXIplug amp play Driver 3 1 0 vi R amp S IMS Generator R amp S SM300 USB 1 8 4 L R amp S IMS Control bmcm meM2oos USB Driver 44 455 n a R amp S IMS Control bmem mem XXX Lib amp Dx Activex Component 4 4 454 n a J R amp S IMS Spectrum Analyzer USB Driver 24 O Start Installation Exit Program If you update EMC32 the R amp S Driver Installer Tool will check for installed drivers and thus selects only drivers with older versions installed for updating
13. R amp S EMC32 AMS32 EMC Measurement Software OTA Measurement Software Installation Manual Re ba m tu e gt ra i eel Fer ro Pate ie Lane Me ered y 1144 5428 42 10 Installation Manual Test amp Measuremen The Installation Manual describes the following R amp S EMC32 AMS32 models and options e R amp S EMC32 e R amp S AMS32 COPYRIGHT Copyright 2013 by Rohde amp Schwarz GmbH amp Co KG All rights reserved Information in this document is subject to change without notice The software described in this document is furnished under a license agreement or nondisclosure agreement The software may be used or copied only in accordance with the terms of those agreements No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or any means electronic or mechanical including photocopying and recording for any purpose other than the purchaser s personal use without the written permission of Rohde amp Schwarz Portions of the software described in this document copyright of Microsoft Corporation All rights reserved Windows 7 Windows 8 Windows 2000 Windows XP Internet Explorer and Windows Installer are trademarks or registered trademarks of Microsoft Corporation in the U S A and other countries iKey amp is a registered trademark of Safenet Inc Pentium is a registered trademark of INTEL Corporation Other brands and their pro
14. ay be started directly via the command D SETUP EXE substitute the correct letter of your CD ROM drive for D 12 After the completion of the R amp S EMC32 AMS32 main installation the appropriate device drivers have to be installed e g NI GPIB VXI Plug amp Play or USB driver For this purpose the EMC32 Driver Installer Tool may be started immediately by ticking the Run Installer for required drivers VXI USB option Refer to the next chapter for further information on this tool J EMC32 InstallShield Wizard InstallShield Wizard Completed The InstallShield Wizard has successfully installed EMC32 V9 00 0093 Click Finish to exit the wizard Next steps after installation update Run Installer for required drivers VXLUSB For information on the next steps please refer to the Installation Guide n J H m Installation Manual 1144 5428 42 10 12 R amp S EMC32 AMS32 Installing R amp S EMC32 AMS32 E 0 R amp S EMC32 AMS32 uses the installation service Windows Installer 3 1 from Microsoft It is already available on Windows XP with the service pack 3 installed and in the base installations of Windows 7 Vista If the Windows Installer is not already installed it will be installed automatically before R amp S EMC32 AMS32 installation is started In this case the setup program will perform a re start of the computer and
15. cards from other manufactures are not supported e Administrator Access Privileges during installation required e The integrated Software Update Manager requires internet access for querying the R amp S webpage on updates and important messages for further information on how to configure the update polling period refer to the EMC32 AMS32 online help If your computer does not meet these requirements the performance of the software may be not ensured Installation Manual 1144 5428 42 10 7 R amp S EMC32 AMS32 Installing R amp S EMC32 AMS32 H nH m HP 3 2 Installation Fundamentals 3 2 1 Installation Folder The following considerations shall give the administrator of the R amp S EMC32 AMS32 computer some hints for the selection of the installation location The folder structure of R amp S EMC32 AMS32 can be split into two sections e Executables and device drivers require only read access during R amp S EMC32 AMS32 runtime e Data files like configuration and calibration files test templates and test results require full file access during EMC32 AMS32 runtime Due to security reasons the standard EMC32 AMS32 operator will be logged in the Windows computer as Standard or Power User This account will not provide write access to the standard Windows program files folder where the R amp S EMC32 AMS32 executables and device drivers will be installed by default For solving
16. de schwarz com Installation Manual 1144 5428 42 10 5 2 Newsletter Service Before you start using R amp S EMC32 AMS32 system software you should register for the R amp S EMC32 AMS32 newsletter service at Rohde amp Schwarz website You will benefit from the registration by receiving information about news and updates of R amp S EMC32 AMS32 Use the following link with a web browser http www rohde schwarz com html update information system html or start the registration dialog via the help menu item gt EMC32 on the Web gt Newsletter Service To register in this manner your computer must be connected to the Internet R amp S EMC32 AMS32 Installing R amp S EMC32 AMS32 L d S n 3 Installing R amp S EMC32 AMS32 3 1 System Requirements Before installing R amp S EMC32 AMS32 you should check that your computer fulfills the following minimum system requirements e Operating System Windows 8 64 bit Windows 7 32 bit and 64 bit Windows XP with SP3 32 bit only e CPU Intel Core models or comparable with core speed gt 2 4 GHz e RAM 4 GB Windows 7 8 1 GB Windows XP or e Hard Disk Space at least 1 GB free e Screen Resolution at least 1280 x 1024 Pixels 65536 colors higher resolution recommended Screen size at least 17 inches e IEEE bus interface from National Instruments with newest IEEE488 2 driver Compatible
17. ducts are trademarks or registered trademarks of their respective holders and should be noted as such Rohde amp Schwarz would like to thank the open source community for their valuable contribution to embedded computing 2013 Rohde amp Schwarz GmbH amp Co KG 81671 Munich Germany Printed in Germany Subject to change Data without tolerance limits is not binding R amp S is a registered trademark of Rohde amp Schwarz GmbH amp Co KG Trade names are trademarks of the owners The following abbreviations are used throughout this manual R amp S EMC32 AMS32 is abbreviated as R amp S EMC32 AMS32 R amp S EMC32 AMS32 Table of Contents Table of Contents Conventions Used in the Documentation 3 M is beje pmum nenna 5 2 Newsletter Service sss esec eee cesse esse eenn enen ennenen 6 3 Installing R amp S EMC32 AMS32 nannnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnnnnn 7 3 1 System HedgUlFemiebi s usua tin aua E RiwUE CE Rid MiSR Uu cesses d EU Edd EE MEE 7 3 2 Installation Fundamentals siiis cuctbn aids dphicS ccs ad aia a oae UY CI EDI esen 8 3 2 1 Installation Folder eee eee 8 3 2 2 Data Security and User Administration sese 8 3 3 Software Installation s i siisii nananana INIM E SUM EEPE Ir ELI SUE S EE 9 3 3 1 New installations eere eee eee eee 10 3 3 2 Driver Installer Tog esse eee 14 3 3 3 Network Installation TOS sese 16 3 3 4 R amp S EMC32 AMS
18. e eee eee 7 T Troubleshooting sss esse ee sese esse sees essere neee 31 U Uninstalling eessseeseeeeeeeses 26 Be as Sra oiae aZe TZ Renk 22 Update Manager sss s sese es sese e sese essere neee 7 Upgrade tette tette ttti 22 Nele ro UI e EE 25 W WIZE s 19 Installation Manual 1144 5428 42 10 32
19. form the following steps 1 From the Start menu select Settings Control Panel Double click on Add Remove Programs Software Click the Install Uninstall tab From the list of programs that you can remove select Rohde amp Schwarz EMC32 Click Add Remove O a A C N In the opened Windows Installer Dialog select Remove and confirm that you want to remove the R amp S EMC32 AMS32 application follow the instructions when it asks you to insert the R amp S EMC32 AMS32 installation CD ROM or press the Cancel button The uninstall program removes all program files folders and registry entries which have been installed during the setup process 7 When the files have been removed the uninstall program indicates that the process is complete Click on the OK button 8 Delete the Rohde Schwarz folder in the Windows Program Files folder using the Windows File Explorer To uninstall iKey software perform the following steps 9 Exit first the program iKey Token Utility if this is active in the task bar i 10 From the Start menu select Settings Control Panel 11 Double click on Add Remove Programs Software 12 Click the Install Uninstall tab 13 Remove the iKey from the USB port 14 From the list of programs that you can remove select Safenet iKey Components Click Add Remove 15 From the list of programs that you can remove select Safenet iKey Driver Click Add Remove BE Installation Manual 1144 542
20. ing an additionally connected mouse The alternative procedure using the keys on the device or the on screen keyboard is only described if it deviates from the standard operating procedures as described in the Quick Start Guide under Basic Operations The terms select and press may refer to any of the described methods i e using a finger on the touchscreen a mouse pointer in the display or a key on the device or on a keyboard m A HH J m ns Installation Manual 1144 5428 42 10 3 R amp S EMC32 AMS32 Introduction 1 INTRODUCTION This document will guide you through the installation process of R amp S EMC32 EMC measurement software and AMS32 OTA measurement software You will find the necessary instructions for installation upgrade the configuration of the software the start of the program and tips on installation troubleshooting If you need further assistance for solving problems during the installation please contact your nearest Rohde amp Schwarz Support Center ROHDE amp SCHWARZ Customer Support Europe Phone 49 4129 12345 E Mail customersupport rohde schwarz com ROHDE amp SCHWARZ Customer Support America Phone 1 888 TEST RSA 1 888 837 8772 selection 2 E Mail customer support rsa rohde schwarz com ROHDE amp SCHWARZ Customer Support Asia Phone 65 65130 488 E Mail customersupport asia roh
21. ling R amp S EMC32 AMS32 n n 7 Select EMC32 AMS32 Software and click on the Next gt button In this step you must select the EMC32 AMS32 main applications and the options you want to install Click on the disk drive or X symbol 4 to either select an option for installation or remove an option If you select a main application you can change the installation path for the executables by clicking on the Change button refer to Installation Fundamentals for further information If you are upgrading from a version V9 x please refer to the Product Cross Reference Table in the chapter Upgrading EMC32 AMS32 for further information about which EMC32 AMS32 options correspond to your product r J EMC32 InstallShield Wizard x p Custom Setup 7 Select the program features you want installed N 7 ms Click on an icon in the list below to change how a feature is installed Feature Descripti S EMC32 EB Emission Measurement ae rn du Basic ponen T amp EMC32 K10 Extension drivers necessary for per E amp EMC32 K22 Extension EMI measurements amp EMC32 K23 Extension nm amp v EMC32 K24 Extension X EMC32 K51 Extension This feature requires 9KB on 6 E EMC32 S Susceptibility Measurement your hard drive It has 4 of 5 i s i subfeatures selected The Hy AMS32 Over The Air Measurements subfeatures require 6649KB on E Er Common EMC32 Options
22. llation Folders x ao O Fred E Cc Execute Configuration El C3 System Correction Tables Attenuation C3 Hardware Setups co OTA Measurements 3 Test Templates L OTA AutoTest ar 4 b Please copy all files of the subdirectories Configuration Attenuation OTA Measurements and OTA Auto Test to the corresponding directories of your actual installation When copying the standard data the AMS32 application should be closed When starting the AMS32 all the standard data are available After this step AMS32 is ready to run the first demo measurement Before the first start of a real EUT measurement the appropriate calibration data for the antennas transducers and the signal paths have to be entered or calibrated for more information on this subject refer to the chapter system calibration in the online help The AMS32 software is now ready for the first start of a demo measurement Before the first EUT measurement can be performed a calibration of the signal paths and the input of the antenna and transducer calibration data may be required n o Installation Manual 1144 5428 42 10 21 R amp S EMC32 AMS32 Upgrading EMC32 AMS32 7 Upgrading EMC32 AMS32 For running EMC32 AMS32 V9 0 you need to upgrade first your base license iKey EM
23. mation on this issue refer to the Online Help chapter Data Security and User Administration 3 3 Software Installation Both the multiple installation of R amp S EMC32 AMS32 and the installation of different R amp S EMC32 AMS32 versions on one computer is not possible If you want to separate EMI and EMS measurements completely you must follow the instructions in the Online Help chapter User Administration Different User Profiles If any previous version of R amp S EMC32 AMS32 is already installed then first you have to uninstall that one Please also refer to the chapters Updating R amp S EMC32 AMS32 and Uninstalling EMC32 AMS32 EMI EMS AMS Thus do not install V9 0 on your test system PC when this license is not available Regarding the upgrade procedure of the iKey please refer to chapter 9 1 o EMC32 AMS32 V9 0 requires an upgrade license for each main application co Installation Manual 1144 5428 42 10 R amp S EMC32 AMS32 Installing R amp S EMC32 AMS32 3 3 1 New Installation All necessary information for the installation and the installation process of R amp S EMC32 AMS32 are provided by the Autostart program on the R amp S EMC32 AMS32 CD ROM Just follow the few easy steps described below and you will have the software installed on your computer ready to use Start of Installation 1 2 AA O Close all running programs Insert the R amp S EMC32 AMS32 CD into your CD ROM drive If Autoru
24. n Options Description EMC32 U95 Upgrade EMI EMS section to V9 x EMC32 K1 Enhanced leveling functionality for Automoti Choose iKey Choose iKey ras iKey Number v 21061F00001B14 z Unie iKey Number for 21061F000024FE z Load iKeys Exit Figure 9 1 Rohde amp Schwarz iKey Merge Tool Program Dialog R Installation Manual 1144 5428 42 10 29 5 Select the option you want to transfer in the table of the source iKey and click on the arrow buttons to move the option to the table of the target iKey Click on the button to Save Changes to iKeys to start the transfer process Do not remove any iKey as long as the transfer process is running Close the program after the transfer is completed o ouo Store the source EMC32 option iKey as a confirmation of your option license R amp S EMC32 AMS32 Troubleshooting 10 Troubleshooting Occasionally users encounter problems during installation Here are some troubleshooting tips you can use that may resolve the problem If you have any further questions read the Readme file or contact the Rohde amp Schwarz Customer Support A Hibernating or Standby mode of Windows may not be supported by the drivers for the IEEE interface or for the iKey Therefore to avoid any possible device driver access errors such a mode should be deactivated in the Power Control dialog of the Windows control panel Before installation shut down any running programs including vi
25. n is enabled on your system the installation starts automatically and you can skip steps 3 and 4 From the Start menu select Run Type D ShowAutoStart bat substitute the correct letter of your CD ROM drive for D Click on the Install EMC32 AMS32 Software button and follow the instructions on the screen read the license agreement enter your name and company name The installation program prompts you to select the product which you want to install EMC32 EMC Measurement Software EMC32 EMC measurement software with EMI and or EMS section will be installed AMS32 OTA Measurement Software AMS32 OTA measurement software will be installed JE EMC32 InstallShield Wizard y uw gt Product Selection FI Choose the product which you like to install v 4 EMC32 EMC Measurement Software EMC32 Test Measurement Software EMI EMS section will be 13 installed Select Deselect the required EMC32 options in the next dialog V EMI Section Emission Measurement EMS Section Susceptibility Measurement 4 AMS32 OTA Measurement Software AMS32 OTA Measurement Software will be installed tallShielc Bak J Net panel If you are updating from a previous version V6 10 20 this dialog will not appear since the setup program has stored your settings in the registry These settings will appear in the next step as default selection Installation Manual 1144 5428 42 10 10 R amp S EMC32 AMS32 Instal
26. ns Used in the Documentation Conventions Used in the Documentation The following conventions are used throughout the R amp S EMC32 AMS32 Installation Manual Typographical conventions Convention Description Graphical user interface All names of graphical user interface elements both elements on the screen and on the front and rear panels such as dialog boxes softkeys menus options buttons etc are enclosed by quotation marks KEYS Key names are written in capital letters and enclosed by quotation marks Input Input to be entered by the user is displayed in italics File names commands Filenames commands coding samples and screen program code output are distinguished by their font Links Links that you can click are displayed in blue font References References to other parts of the documentation are enclosed by quotation marks Other conventions Remote commands Remote commands may include abbreviations to simplify input In the description of such commands all parts that have to be entered are written in capital letters Additional text in lower case characters is for information only Procedure descriptions When describing how to operate the device several alternative methods may be available to perform the same task In this case the procedure using the touchscreen is described where available Any elements that can be activated by touching can also be clicked us
27. played here the iKey has been detected correctly Token Settings Help General Information User Tools Token Details The General Information tab displays information about the 3 connected iKey Item Value Token Type iKey 1000 Token Token Name Serial Number 0121 087F 0000 0001 Driver Version 4 1 Build 267 Firmware Version 1 1 Used Memory Bytes Free Memory Bytes Total Memory Bytes Software Figure 3 1 iKey Token Utility Program Dialog Make sure that the USB interface is activated in the BIOS settings of your o computer The standard installation only supports up to 4 iKeys to be connected at once Use the EMC32 iKey Merge Tool refer to chapter below to add EMC32 Kxx options to a EMC32 E S main license key in order to reduce the number of iKeys required to run R amp S EMC32 AMS32 Disable Windows energy saving modes since the communication between a running EMC32 AMS32 will be lost after re starting the PC m M gen e Installation Manual 1144 5428 42 10 17 R amp S EMC32 AMS32 Starting the program 4 Starting the program Once the installation of R amp S EMC32 AMS32 is finished an R amp S EMC32 AMS32 icon is displayed on your desktop Simply double click it to run the program You may also start the program from the Start button on your Windows desktop To launch the program using the Start button
28. red for this action you need first to install EMC32 AMS32 V9 as described in the next chapter 7 3 2 Software Upgrade Procedure If you upgrade the software the R amp S EMC32 AMS32 system data and test results will not be deleted the upgrade only replaces the program Nevertheless for the safety of your data we recommend making a backup of all o test and calibration data stored in the EMC32 folder Use the EMC32 backup restore utility for this purpose refer to R amp S EMC32 AMS32 Data Backup for further information For updating R amp S EMC32 AMS32 perform the following steps provided that you have not received other instructions together with the upgrade 1 Run a backup within R amp S EMC32 AMS32 to save your existing data N Any uninstalling and reinstalling of the iKey software is not required eo Perform the steps 1 10 from the chapter 3 3 1 Use the same installation path as used by the currently installed R amp S EMC32 AMS32 For the selection of the main applications and options to install refer to chapter 7 1 gt A Do not run the configuration wizard after a successful upgrade e Restore any device driver configuration files if you have changed the original files delivered with the R amp S EMC32 AMS32 setup program Installation Manual 1144 5428 42 10 25 R amp S EMC32 AMS32 Uninstalling R amp S EMC32 AMS32 8 Uninstalling R amp S EMC32 AMS32 To uninstall R amp S EMC32 AMS32 per
29. rus checking programs Usually virus checking software has little or no impact on the installation process however if you are running such software and encounter difficulties with your R amp S EMC32 AMS32 installation turning off the virus checking programs and then re installing often solves the problem If you receive a message during the installation process that a DLL of Windows is used and therefore cannot be upgraded quit this message with OK and the installation process will be continued this typically indicates that the latest service pack is not installed Usually this has no further influence on a successful installation of R amp S EMC32 AMS32 Delete any files in your temporary folder This folder is determined by the TEMP environment variable Usually it is located in C TEMP or CAWINDOWS TEMP Run a disk scanning utility Hard drive errors can cause problems with the installation process Some Microsoft Windows systems contain a utility named ScanDisk you can use If you have questions about disk scanning utilities see your system administrator Copy the R amp S EMC32 AMS32 setup CD to your hard drive then run SETUP EXE from your hard drive Check to make sure there was enough free disk space on your hard drive The setup process should notify you if there is not enough free disk space prior to installation Always use in the Regional Options tab index for Numbers and Currency the Decimal symbol instead of Do
30. rz EMC32 System Frequency Lists Graphic C Program Files Rohde Schwarz EMC32 System Graphic HWSetups C Program Files Rohde Schwarz EMC32 System Hardware Setups TestTemp C Program Files Rohde Schwarz EMC32 System Test Templates CalibTemp C Program Files Rohde Schwarz EMC32 System Calibration Setups BE SSS Installation Manual 1144 5428 42 10 23 Icons C Program Files Rohde Schwarz EMC32 System Icons Tests C Program Files Rohde Schwarz EMC32 Tests EutInfos C Program Files Rohde Schwarz EMC32 System EUT Information ReportSetups C Program Files Rohde Schwarz EMC32 System Report Setups Reports C Program Files Rohde Schwarz EMC32 System Reports RefCalib C Program Files Rohde Schwarz EMC32 System Reference Calibrations DeviceList C Program Files Rohde Schwarz EMC32 Execute Configuration EMC32 DeviceList R amp S EMC32 AMS32 Upgrading EMC32 AMS32 7 3 Upgrade Procedure 7 3 1 Base License iKey Upgrade Before starting the upgrade to version 9 check that you have the appropriate upgrade licenses available for your base licenses iKeys as listed in the table below EMC32 AMS32 Base License EMC32 AMS32 Upgrade License EMC32 S EMC32 U9S EMC32 EB EMC32 U9E AMS32 AMS32 U9 Please contact your sales representative for further information on upgrade licenses For upgrading the base license iKey please follow the instructions in chapter 9 1 Since the iKey Merge Tool is requi
31. server Hereby it should be guaranteed that an appropriate network speed is available Otherwise performance problems in R amp S EMC32 AMS32 may appear Hence you should first install R amp S EMC32 AMS32 on your local hard disk as described above administrator rights will be required After this step you can move the paths of the R amp S EMC32 AMS32 folders onto the network server For more details about this item please refer to the chapter OPTIONS File Location in the EMC32 AMS32 Online Help It is required that you have read write access on the corresponding network drive If you are not sure about any of the options have your system administrator help you with installing R amp S EMC32 AMS32 3 3 4 R amp S EMC32 AMS32 Data Backup The data backup of the measurement data as well as the system configuration is recommended cyclically Hereby all selected R amp S EMC32 AMS32 files are written into a compressed file in the ZIP format R amp S EMC32 AMS32 therefore provides a utility function which allows to backup or a restore the complete system configuration and measurement results The backup restore dialog is opened via File Backup Restore For more details about this item please refer to the chapter Backup and Restore Data and Configuration in the EMC32 AMS32 Online Help You can archive or move either individual files or complete tests out of these directories These files and tests will no longer be accessible by R amp S
32. st system PC when this license is not available Regarding the upgrade procedure of the iKey please refer to chapter 9 1 New Installation In that case apply the following steps Before you uninstall the previous version do a backup of all data folders using the Backup utility refer to the chapter R amp S EMC32 AMS32 Data Backup for further information m Now upgrade EMC32 AMS32 refer to the chapter Upgrade Procedure for further information Upgrade Procedure d Run EMC32 AMS32 once to complete the setup and close the application gt A In the data root folder open the file data root folder gt Configuration EMC32 ini with Notepad or any other text editor Search for the section SystemPaths where EMC32 AMS32 stores the path information for all data folder SYSTEM and TESTS Change the folder path for all lines in this section and save the INI file 6 Run EMC32 AMS32 and restore all data using the EMC32 AMS32 restore function e If you use the R amp S EMC32 AMS32 user login or a split R amp S EMC32 AMS32 o configuration with several INI files it will be necessary to do the adaptation of steps 4 5 for each INI file Example SystemPaths Tables C Program Files Rohde Schwarz EMC32 System Tables Correction C Program Files Rohde Schwarz EMC32 System Correction Tables LimitLines C Program Files Rohde Schwarz EMC32 System Limit Lines FreqLists C Program Files Rohde Schwa
33. subject refers to the chapter system calibration in the online help To run the Configuration Wizard perform the following steps 1 Run EMC32 as described in the previous chapter 2 If the start dialog is activated you will find a symbol there to start the configuration wizard Welcome to AMS32 Load Most Recent Test Load Test or Create New Test Open Test Template i x Start Configuration Wizard gt Close this Dialog Starts the Configuration Wizard Use this wizard to configure EMC32 right after installation or e g for demo purposes Do not show this dialog again when starting Figure 5 1 Start Dialog of EMC32 3 You may also start the wizard via the menu entry Extras gt Wizards Configuration Wizard m J MM E E cant Installation Manual 1144 5428 42 10 19 R amp S EMC32 AMS32 EMC32 Configuration E 4 The following dialog will appear which contains a tab for EMI and or EMS depending on the installed main applications 5 Inthe first step select the measurement category radiated and or conducted 6 In the next step you select the device type which is available in your system for each device class and set the appropriate interface or interface address 7 After you have completed all your inputs you may start the configuration process by clicking the button Finish Config
34. t as reference Installation Manual 1144 5428 42 10 28 R amp S EMC32 AMS32 Using the LEN Merge Tool 9 2 Merge Option iKey to a Base License iKey To reduce the number of required iKeys for running EMC32 the iKey Merge Tool has been installed with EMC32 This tool allows transferring the contents of an EMC32 option iKey EMC32 Kxx to a main license iKey EMC32 EB or EMC32 S or vice versa Combining an EMC32 EB EMC32 S or AMS32 iKey is not supported by the o iKey Merge Tool For merging an EMC32 Kxx option iKey to an EMC32 EB or S main license iKey perform the following steps Do not remove an iKey or shutdown your PC when the iKey Merge Tool is o running since the contents of the iKeys may be lost Shut down any running programs Connect both iKeys to your PC the source and the target iKey m Click the Start button on your desktop o Select Programs gt Rohde amp Schwarz gt EMC32 Tools gt iKey Merge Tool A dialog will appear In the iKey Merge Tool click on the Load iKeys button to read the information stored on both iKeys Rohde amp Schwarz EMC32 iKey Merge Tool 9 0 x Mode m Serial Number Mode Serial S N 100333 Mode EMS Serial S N 100435 Mode OPT r More r More Production Date 2012 03 06 Production Date 2012 03 06 1sp3 gr 1sp3 gr m Comment r Comment iKey ready iKey ready Option Descriptio
35. uration Wizard EMS EMI 1st Measurement Category Select one or both measurement categories d V EMI radiated p 2 Devices Select the devices which are available in your system Receiver ESU 40 w IEEE Address 420 Tower Maturo Antenna Tower _v IEEE Address EX 15 Tumtable Maturo Turntable v IEEE Address fis Eo SMB100A v EEEAddes a Here a device must be selected Figure 5 2 Dialog of the Configuration Wizard EMI and EMS tab index The EMC32 software is now ready for the first start of a demo measurement Before the first EUT measurement can be performed a calibration of the signal paths and the input of the antenna and transducer calibration data may be required m eng OmR se n Installation Manual 1144 5428 42 10 20 R amp S EMC32 AMS32 AMS32 Configuration 6 AMS32 Configuration Before running a measurement with AMS32 the software must be adapted to your system i e you must define the available measurement devices through which interfaces these devices may be addressed how the devices are connected with each other and how a test using this devices should be performed After the first installation of the AMS32 the data base is empty For a quick Demo installation the CD contains a Standard Data Configuration which have to be copied to the corresponding directory of the actual AMS32 insta