SMA SPEEDWIRE/WEBCONNECT Piggy-Back
Contents
1. Knowledge of how to deal with the dangers and risks associated with installing and using electrical devices and plants Knowledge of all applicable standards and directives Knowledge of how an inverter works and is operated Knowledge of and adherence to this document and all safety precautions 8 SPW WebconPB lA en 1 1 Installation Manual SMA Solar Technology AG 2 Safety 2 4 Safety Precautions Electric Shock Lethal voltages are present in the conductive parts of the inverter Prior to performing any work on the inverter disconnect the inverter from any voltage sources on the AC and DC sides see inverter installation manual Observe the waiting time to allow the capacitors to discharge Burn Hazards Some parts of the inverter enclosure can get hot during operation e During operation touch the inverter on the enclosure lid only Environmental Influences When closed and with the ESS plugged in the inverter has the degree of protection IP65 The inverter is thus protected against dust intrusion and water penetration Dust intrusion and water penetration can damage the inverter e If the ESS is not plugged in the inverter must be protected against dust and water e Firmly plug ESS in again after performing any work on the inverter 2 5 Operating Information Selecting a Suitable Internet Tariff for Small Plants When using the new Webconnect function a constant Internet connection is required Depending on
2. 2 Start Sunny Explorer and create a plant see Sunny Explorer help 6 4 Plant Registration in Sunny Portal 6 4 1 Registering a Small Plant in Sunny Portal Requirements DL The small plant must be commissioned see Section 6 2 The inverter with Piggy Back must be in feed in operation The plant must be connected to a router with permanent Internet connection see router manual PIC and RID must be available for the Piggy Back Your computer must have an Internet connection JavaScript must be activated in the Internet browser In Sunny Portal you can manage several plants A maximum of four inverters with integrated O O O O O i Maximum permissible number of devices for a small plant in Sunny Portal Piggy Back is permissible per small plant Small plant with Piggy Back cannot be combined with other plants IF you have already registered a plant in Sunny Portal with another communication device e g Sunny WebBox you will still need to create a separate small plant with Piggy Back It is not possible to combine the Piggy Back and other communication devices within one plant in Sunny Portal Sunny Portal treats the existing plant and the new small plant with Piggy Back as separate plants Create a new small plant with Piggy Back Starting the Plant Setup Assistant in Sunny Portal The Plant Setup Assistant is a step by step guide of the processes required for user registration and the registration of your plant in Sunn
3. Technology South Africa Pty Ltd Centurion Pretoria SMA Solar UK Ltd Milton Keynes SMA Hellas AE AOrnva Bwxre EMa a l spuna SMA Solar Thailand Co Ltd NINA SMA Technology Korea Co Ltd N International SMA Service Line Niestetal SMA Middle East LLC 10 Contact 91 22 61713888 39 02 8934 7299 Gratuito em 800 20 89 87 Portugal 351 2 12 37 78 60 Internacional 08600 SUNNY 08600 78669 International 44 1908 304899 27 12 643 1785 801 222 9 222 International 30 212 222 9 222 66 2 670 6999 82 2 508 8599 basal A gal Toll free worldwide 00800 SMA SERVICE 800 762 7378423 SPW WebconPB lA en 1 1 31 SMA Solar Technology
4. by SMA Service If your inverter is in need of a firmware update contact the SMA Service Line see Section 10 The software version of Sunny Explorer is older than version 1 05 Corrective measures Download Sunny Explorer from software version 1 05 from www SMA Solar com and install Firewall or IP filter settings are not correct Corrective measures e Adjust the firewall or IP filter settings see firewall or router manual The Piggy Back does not have a valid IP address Corrective measures e Make sure DHCP is enabled for the router Inverters with retrofitted Piggy Back shut down overnight It is therefore not possible to establish any connection to these inverters As soon as the inverters switch on in the morning they will be accessible again Piggy Back update does not The feed in power of the inverter is less than 50 W initialise Corrective measures e Carry out update once the feed in power of the inverter is at least 50 W Installation Manual SPW WebconPB IA en 1 1 27 8 Troubleshooting SMA Solar Technology AG 8 2 Performing a Piggy Back Update Piggy Back updates are performed via Sunny Explorer There is no need to replace the Piggy Back Existing inverter settings and data are retained after the update Only carry out an update providing that the feed in power of the inverter is sufficient at least 50 W After a successful update restart Sunny Explorer 28 SPW WebconPB IA en 1 1 Installa
5. A Figure 6 Overview of the connection area ltem Description A Slot for Piggy Back B Opening in the inverter enclosure with filler plug C Cable route to communication terminal D Communication terminal E Jumper slot for communication 14 SPW WebconPB IA en 1 1 Installation Manual SMA Solar Technology AG 5 Connection SB 3300 11 SB 3800 11 A A n i qee meme gli o Li a BEBE TTT Figure 7 Overview of the connection area ltem Description A Slot for Piggy Back B Opening in the inverter enclosure with filler plug C Cable route to communication terminal D Communication terminal E Jumper slot for communication Installation Manual SPW WebconPB lA en 11 5 Connection SMA Solar Technology AG SMC 6000A 11 SMC 7000HV 11 aw AAA AE E NO Y Figure 8 Overview of the connection area Item Description A Slot for Piggy Back B Opening in the inverter enclosure with filler plug C Cable route to communication terminal D Communication terminal E Jumper slot for communication 16 SPW WebconPB IA en 1 1 Installation Manual SMA Solar Technology AG 5 Connection 5 2 Cable Requirements and Information on Routing The cable length and quality have an effect on the signal quality in the Speedwire network Observe the following information and cable requirements i Disturbance of dat
6. Installation Manual SMA SPEEDWIRE WEBCONNECT Piggy Back SPW WebconPB lA en 11 Version 1 1 ENGLISH Legal Provisions SMA Solar Technology AG Legal Provisions The information contained in this document is the property of SMA Solar Technology AG Publishing its content either partially or in full requires the written permission of SMA Solar Technology AG Any internal company copying of the document for the purposes of evaluating the product or its correct implementation is allowed and does not require permission SMA Warranty You can download the current warranty conditions from the Internet at www SMA Solar com Trademarks All trademarks are recognized even if not explicitly identified as such A lack of identification does not mean that a product or symbol is not trademarked The BLUETOOTH word mark and logos are registered trademarks owned by Bluetooth SIG Inc and any use of these marks by SMA Solar Technology AG is under license Modbus is a registered trademark of Schneider Electric and is licensed by the Modbus Organization Inc QR Code is a registered trademark of DENSO WAVE INCORPORATED Phillips and Pozidriv are registered trademarks of Phillips Screw Company Torx is a registered trademark of Acument Global Technologies Inc SMA Solar Technology AG Sonnenallee 1 34266 Niestetal Germany Tel 49 561 9522 0 Fax 49 561 9522 100 www SMA de E mail infoGSMA de 2004 to 2014 SMA Solar Techn
7. Section 2 2 For safety reasons it is not permitted to modify the product or install components that are not explicitly recommended or distributed by SMA Solar Technology AG for this product The enclosed documentation is an integral part of this product Read and observe the documentation Keep the documentation in a convenient place for future reference Only use the Speedwire Webconnect Piggy Back in accordance with the information provided in the enclosed documentation Any other use may result in personal injury or property damage 2 2 Supported Products SMA inverter The Speedwire Webconnect Piggy Back must only be used in the following inverters with at least the given firmware version Sunny Boy Sunny Mini Central From firmware version SB 1300TL 10 SB 1600TL 10 SB 2100TL 4 30 SB 3300 11 SB 3800 11 4 02 SMC 60004 11 4 33 SMC 7000HV 11 2 21 Firmware updates on the inverters can only be carried out by SMA Service If your inverter is in need of a firmware update contact the SMA Service Line see Section 10 Additional SMA products e Sunny Explorer from software version 1 05 Sunny Explorer is available free of charge at www SMA Solar com e Cluster Controller 2 3 Qualifications of Skilled Persons The work described in this document must be performed by skilled persons only Skilled persons must have the following qualifications Training in the installation and commissioning of electrical devices and plants
8. Section 5 1 Observe the permitted cable route see Section 5 1 and the pin assignment as follows Inverter Network cable communication terminal Pin Signal EIA TIA 568A 8 wire Profinet 4 wire Wire colour Wire colour 2 TD white green yellow 3 TD green orange 7 RD white orange white 5 RD orange blue 16 Make sure that there are no jumpers in the communication jumper slot position of jumper slot for communication see Section 5 1 20 SPW WebconPB IA en 1 1 Installation Manual SMA Solar Technology AG 5 Connection 17 Attach an RJA5 connector to the other end of the cable see manufacturer s manual Observe the pin assignment of the network cable as follows Network cable Signal Pin RJ45 plug EIA TIA 568A 8 wire Profinet 4 wire Wire colour Wire colour TD 1 white green yellow TD 2 green orange RD 3 white orange white RD 6 orange blue 18 Subject to the required network topology connect the other end of the cable to a router network switch or Cluster Controller see manual of the respective device To do this a router with Internet connection must be connected to the plant 5 4 Installing the Piggy Back 1 A DANGER Danger to life due to electric shock when opening the inverter Lethal voltages are present in the conductive parts of the inverter e If the inverter is closed proceed as follows e Disconnect the inverter from any voltage sources on the AC and DC sides see the inverter install
9. W WebconPB IA en 1 1 1800 SMA AUS 1800 762 287 61 2 9491 4200 Toll free for Australia International 32 15 286 730 420 235 010 417 Medium Power Solutions Wechselrichter 49 561 9522 1499 Kommunikation 49 561 9522 2499 SMA Online Service Center www SMA de Service Hybrid Energy Solutions Sunny Island 49 561 9522 399 PV Diesel 49 561 9522 3199 Hybridsysteme Power Plant Solutions 49 561 9522 299 900 14 22 22 Sunny Central Llamada gratuita en Espa a 34 902 14 24 24 Medium Power Solutions 33 472 09 04 40 33 472 09 04 41 Hybrid Energy Solutions 33 472 09 04 42 Internacional Onduleurs Communication Sunny Island Power Plant Solutions Sunny Central 33 472 09 04 43 Installation Manual SMA Solar Technology AG India Italia Kuttpoc Kibris Luxemburg Luxembourg Magyarorsz g Nederland Osterreich Per Polska Portugal Rom nia Schweiz Slovensko South Africa United Kingdom EAAd a Bbnrapua Ch Sto 971 2 234 6177 Other countries Installation Manual SMA Solar India Pvt Ltd Mumbai SMA Italia S r l Milano Bherre EMada Bkz EAAdd a Yunanistan Siehe Belgien Voir Belgique l sd Cesko Csehorsz g zie Belgien Belgi amp Siehe Deutschland Ver Espa a Patrz Cesko Czechy SMA Solar Technology Portugal Unipessoal Lda Lisboa Vezi esko Cehia Siehe Deutschland pozri esko esk republika SMA Solar
10. a transmission due to AC Cables When AC cables are in operation they generate an electromagnetic field which may induce interference in network cables during data transmission e Lay the network cables using suitable fastening material and with a minimum clearance of 50 mm to the AC cables Cable requirements DL Cable length between two nodes max 100 m O Crosssection at least 2x2x0 22 mm or at least 2x2 AWG 24 DL Cable type 100BaseTx CATS with shielding S UTP F UTP or higher O UV resistant for outdoor use O Type of plug RJ45 SMA Solar Technology AG recommends the following cable types e For outdoor use SMA COMCAB OUTxxx e For indoor use SMA COMCAB INxxx The cables are available in the lengths xxx 100 m 200 m 500 m 1 000 m 5 3 Connecting the Cable to the Communication Terminal i Figures in this section The work steps in this section are supported by figures of the inverter types SB 3300 11 and SB 3800 11 The procedure for other inverter types is analogous see Section 5 1 Requirement O For Italy There must be an available network operator gateway with network connection for telecontrol protocol IEC 61850 Additionally required material not included in the scope of delivery O 1 network cable see Section 5 2 O 4 bootlace ferrules O 1 RJA5 connector Installation Manual SPW WebconPB lA en 1 1 17 5 Connection SMA Solar Technology AG Procedure 1 A DANGER Danger to life due to electric shock when openi
11. ation manual Observe the waiting time to allow the capacitors to discharge e Open the inverter see inverter installation manual 2 Plug the Piggy Back into the female connectors at the slot in the inverter for position of slot see Section 5 1 3 Stick one of the labels with the data for registration in Sunny Portal PIC and RID on the outside of the inverter in the vicinity of the type label 4 Close the inverter see inverter installation manual Installation Manual SPW WebconPB lA en 1 1 21 6 Commissioning SMA Solar Technology AG 6 Commissioning 6 1 Commissioning a Large Scale PV Plant with Cluster Controller Requirements O The cable must be connected to the communication terminal see Section 5 3 The Piggy Back must be installed in the inverter see Section 5 4 DL Subject to the required network topology the Cluster Controller must be connected to the Speedwire network see Cluster Controller installation manual Procedure 1 Commission all inverters with installed Piggy Back see inverter installation manual 2 i Deactivating the Webconnect function of the inverters In a large scale PV plant with Cluster Controller communication with Sunny Portal takes place via the Cluster Controller itself For optimal operation of large scale PV plants with Cluster Controller deactivate the factory activated Webconnect function of the inverter with installed Piggy Back see Cluster Controller us
12. ble remove 40 mm from the cable sheath and cable shield Make sure that no pieces of cable are dropped into the inverter 11 Atthe end of the cable strip the insulation of the four required wires by 6 mm Take the type of cable into account as listed below Network cable Signal EIA TIA 568A 8 wire Profinet 4 wire Wire colour Wire colour TD white green yellow TD green orange RD white orange white RD orange blue 12 Shorten all other wires flush with the cable sheath 13 Attach the bootlace ferrules to the wire ends Installation Manual SPW WebconPB lA en 1 1 19 5 Connection SMA Solar Technology AG 14 INNI Danger to life due to electric shock in case of incorrect cable insulation If a cable is not correctly insulated high voltages may occur on the cable outside the inverter e lead the cable into the inverter through the silicone tube The silicone tube must completely cover the cable and the wires inside the inverter enclosure e Cut the silicone tube to the required length as necessary e Fix the silicone tube in position with cable ties at the beginning and end of the cable as necessary Trim the ends of the cable ties This will prevent the ends of the cable ties causing damage to hot components in the inverter 15 Connect the wire ends to the communication terminal in the inverter at screw terminals 2 3 5 and 7 torque 0 23 Nm for position of the communication terminal see
13. e is needed The type label must be permanently affixed to the Speedwire Webconnect Piggy Back 12 SPW WebconPB IA en 1 1 Installation Manual SMA Solar Technology AG 4 Product Description Supplementary Label with Data for Registration in Sunny Portal The supplementary label is located on the front panel of the Speedwire Webconnect Piggy Back The data for registration in Sunny Portal is to be found on the supplementary labels supplied A pic D XXXXXXXXXXXXXXX B rip XXXXXX C MAC Address XXXXXXXXXXXX C Figure 4 Layout of the supplementary label Item Explanation A Identification key of the Piggy Back for registration in Sunny Portal B Registration ID of the Piggy Back for registration in Sunny Portal C MAC address of the Piggy Back Symbol on the Supplementary label Symbol Description Explanation C CE marking The product complies with the requirements of the applicable EU directives 4 4 Cable Gland The cable gland provides a sturdy tightly sealed connection of the network cables with the inverter enclosure The cable gland also protects the inverter from dust intrusion and moisture penetration A B C Figure 5 Product description Cable gland Item Description A Swivel nut B Adaptor PG16 to M16 C Counter nut SPW WebconPB lA en 1 1 13 Installation Manual 5 Connection SMA Solar Technology AG 5 Connection 5 1 Inverter Connection Area SB 1300TL 10 SB 1600TL 10 SB 2100TL
14. er manual 6 2 Commissioning a Small Plant Requirements O The cable must be connected to the communication terminal see Section 5 3 The Piggy Back must be installed in the inverter see Section 5 4 The plant must be connected to a router with Internet connection DHCP must be enabled for the router L1 L1 g For Italy in order to adjust the Sunny Explorer settings for receiving control signals from the Piggy Back you must have a personal SMA Grid Guard code see Sunny Explorer help Procedure 1 Commission all inverters with installed Piggy Back see inverter installation manual 2 For plants in Italy in order to adjust the settings to receive control signals from the network operator in the Piggy Back follow the steps below Connect to Sunny Explorer see Section 6 3 2 Enter your personal SMA Grid Guard code in Sunny Explorer see Sunny Explorer help 22 SPW WebconPB IA en 1 1 Installation Manual SMA Solar Technology AG 6 Commissioning Setthe following parameters in Sunny Explorer for setting parameters in a device see Sunny Explorer help External Communication gt IEC 61850 configuration Parameter Value Range Resolution Default Application ID O to Ox4000 1 Ox4000 Goose Mac address 01 0C CD 01 00 00 1 01 0C CD 01 02 00 01 0C CD 01 02 00 e In the field Application ID enter the Application ID of the network operator gateway You will receive this value from your network operator You ca
15. llation manual Remove the Piggy Back from the communication interface Release the screw terminals at the communication terminal in the inverter and remove the wires Remove the silicone tube from the cable Unscrew the swivel nut of the cable gland Pull the cable out of the inverter Unscrew the counter nut of the cable gland and remove the cable gland Seal the enclosure opening of the inverter with the corresponding filler plug Close the inverter see inverter installation manual Disposing of the Piggy Back Dispose of the Piggy Back in accordance with the regulations for the disposal of electronic waste applicable at the installation site SPW WebconPB IA en 1 1 Installation Manual SMA Solar Technology AG 8 Troubleshooting 8 Troubleshooting 8 1 General Errors Problem Cause and corrective measures The inverter with Piggy Back There is no Speedwire connection cannot be accessed Corrective measures e Ensure that all network cable plugs are inserted and locked e Ensure that all inverters in the plant are in operation e Ensure that the plant router is switched on e Ensure that the Piggy Back is connected correctly see Section 5 3 e Ensure that the Cluster Controller is connected to the local plant network see Cluster Controller installation manual The firmware version of the inverter is not supported see Section 2 2 Corrective measures e An inverter firmware update can only be carried out
16. n Manual SPW WebconPB lA en 1 1 5 1 Information on this Document SMA Solar Technology AG Typography Typography Explanation Example bold e Display messages e The value can be read from the Elements of a user interface Energy field SConmechiols Select Settings amp Bismentet beselscted e Enter the value 10 in the Minutes field e Elements to be entered gt e Connects several elements e Select Settings gt Date that are to be selected Button Key e Button or key to be selectedor Select Next pressed Nomenclature Full designation Designation in this document PV plant Plant SMA Cluster Controller Cluster Controller SMA Speedwire Speedwire SMA Speedwire Webconnect Piggy Back Piggy Back SMA Webconnect function Webconnect function SMA inverter 6 SPW WebconPB lA en 1 1 Inverter Installation Manual SMA Solar Technology AG 2 Safety 2 Safety 2 1 Intended Use The Speedwire Webconnect Piggy Back is a Speedwire communication interface with Webconnect function for inverters Speedwire is a cable based type of communication based on the Ethernet standard and the communication protocol SMA Data2 This enables inverter optimised 10 100 Mbit data transmission between Speedwire devices in PV plants The Webconnect function enables data transmission between a small plant and the Internet portal Sunny Portal In Sunny Portal a maximum of four inverters can be combined in a Sunny Portal plant In Italy the Speed
17. n enter a value between O and 16384 The value 16384 indicates deactivation In the field Goose Mac address enter the MAC address of the network operator gateway from which the Piggy Back is to receive control commands You will receive this value from your network operator If all MAC addresses are to be accepted in the adjustable domain enter 01 0C CD 01 02 00 6 3 Managing Small Plants with Sunny Explorer 6 3 1 Functions and Parameter Settings in Sunny Explorer The following functions for plant management in Sunny Explorer are available Overview of the plant status Graphic display of key plant data device data and energy values Parameterisation of individual devices or an entire device class Simple diagnostics thanks to the display of faults and events Data export of inverter energy values and events in CSV format Piggy Back update You can change the following parameters in Sunny Explorer Device name of the inverter Automatic IP configuration On Off DNS IP gateway IP IP address subnet mask Webconnect function On Off IEC 61850 configuration for plants in Italy up to 6 kW Installation Manual SPW WebconPB IA en 1 1 23 6 Commissioning SMA Solar Technology AG 6 3 2 Connecting to Sunny Explorer Requirements The plant must be commissioned see Section 6 2 O The inverter with Piggy Back must be in feed in operation Procedure 1 Connect the computer to the router network switch with a network cable
18. ng the inverter Lethal voltages are present in the conductive parts of the inverter e Disconnect the inverter from any voltage sources on the AC and DC sides see the inverter installation manual Observe the waiting time to allow the capacitors to discharge Open the inverter see inverter installation manual Push one filler plug from the inside out of the bottom of the inverter enclosure 4 Attach the cable gland to the enclosure opening using the counter nut Ensure that the grooved side of the counter nut is facing the inverter enclosure 5 Gauge the length from the communication terminal to the counter nut on the cable gland using the cable and mark the position on the cable Be sure to take the permitted cable route into account see Section 5 1 6 Below the marked position remove 20 mm from the cable sheath This will enable contact between the screening clamp and the cable shield in the cable gland 7 Unscrew the swivel nut of the cable gland but do not remove it 18 SPW WebconPB lA en 11 Installation Manual SMA Solar Technology AG 5 Connection 8 Gradually guide the end of the cable through the cable gland into the inverter until you can hear the screening clamp grip onto the cable shield 9 Tighten the swivel nut of the cable gland This will prevent the cable from slipping and the contact between screening clamp and cable shield being lost 10 Atthe end of the ca
19. nstallation Manual SPW WebconPB lA en 1 1 3 Table of Contents SMA Solar Technology AG 7 DECOMMISSIONING opu daria ida 26 7 1 Removing the Piggy Back o oooooooooooooooomoo 26 7 2 Disposing of the Piggy Back ori taa 26 8 Troubleshooting is 2i ki REN ORA E EA 27 Bul A marqueto dus d arare a de ru e eit 27 8 2 Performing a Piggy Back Update 28 9 Technical Dalia E EP EI ERES eS 29 TO Coniac sessar gsr oN ESEE d aped eben 30 SPW WebconPB lA en 1 1 Installation Manual SMA Solar Technology AG 1 Information on this Document 1 Informationon this Document Validity This document is valid for device type SWPB 10 BG1 from hardware version A and firmware version 1 00 00R Target Group This document is for skilled persons Only qualified personnel are allowed to perform the tasks described in this manual see Section 2 3 Qualifications of Skilled Persons page 8 Symbol Explanation A DANGER Indicates a hazardous situation which if not avoided will result in death or serious injury or serious injury A CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Indicates a situation which if not avoided could result in property damage Information that is important for a specific topic or goal but is not safety relevant Indicates an essential requirement for achieving a specific goal Desired result x RD I A problem that might occur Installatio
20. ology AG All rights reserved 2 SPW WebconPB lA en 1 1 Installation Manual SMA Solar Technology AG Table of Contents Table of Contents 1 Information on this Document o ooooooooooo 5 2 Sale ari rias 7 Dl ode 7 27 SUpponed Poitiers 8 2 3 Qualifications of Skilled Persons o o ooooooooo o 8 244 Safety PRECAUTIONS x see be ia re 9 2 5 Operating Information siate 9 3 Scope of Delivery Aids 10 Product Description iii 11 4 1 SMA Speedwire Webconnect Piggy Back 11 4 2 Possible Network Topologies o oooooooooomooo 12 AD Typelabel A IA 12 AA CIR 13 DS CONNGCHON xiii 5s saree aired dean sue ei 14 Sl inverter Connection JTed avo dud renasterii ds 14 5 2 Cable Requirements and Information on Routing 17 5 3 Connecting the Cable to the Communication Terminal 17 5 4 Installing the Piggy Backo iu sissi gdr 21 6 COMMISSIONING sessions 22 6 1 Commissioning a Large Scale PV Plant with Cluster Controller 22 6 2 Commissioning a Small Plant 20 22 6 3 Managing Small Plants with Sunny Explorer 23 6 3 1 Functions and Parameter Settings in Sunny Explorer 23 6 3 2 Connecting to Sunny Explorer 24 6 4 Plant Registration in Sunny Portal 24 6 4 1 Registering a Small Plant in Sunny Portal 24 6 4 2 Registering a Large Scale PV Plant with Cluster Controller in Sunny Portal esca ds 25 I
21. pted The Speedwire Webconnect Piggy Back is available as a retrofit kit Installation Manual SPW WebconPB IA en 1 1 11 4 Product Description SMA Solar Technology AG Figure 2 Layout of the SMA Speedwire Webconnect Piggy Back Item Description A Female connector Label with PIC and RID for Registration of a Small Plant in Sunny Portal To activate the Piggy Back in Sunny Portal you will need the PIC and RID numbers printed on the supplied label After installation of the Piggy Back a label should be affixed on the exterior of the inverter in the vicinity of the type label Keep the other label in a safe place for future reference 4 2 Possible Network Topologies The possible network topologies depend on the devices used and on the number of network ports The Speedwire Webconnect Piggy Back is equipped with one network port For further information on network topologies refer to the Technical Information SMA Speedwire Fieldbus at www SMA Solar com 4 3 Type Label Type Label The type label clearly identifies the Speedwire Webconnect Piggy Back The type label is located on the front panel of the Speedwire Webconnect Piggy Back A swpp 1 0 BG1 Figure 3 Layout of the type label Item Explanation A Device type B Serial number C Hardware version The information on the type label is required for safe use of the Speedwire Webconnect Piggy Back and for reference if customer support from the SMA Service Lin
22. the quality of the Internet connection the transmission volume for an inverter is between 150 MB and 550 MB per month When using the plant overview in Sunny Portal with live data display there is an additional data volume of 600 kB per hour e SMA recommends using an Internet tariff with a flat rate e Since Sunny Portal is permanently connected to the Internet time based billing systems should be avoided High costs could be incurred Installation Manual SPW WebconPB lA en 1 1 9 3 Scope of Delivery SMA Solar Technology AG 3 Scope of Delivery Check the scope of delivery for completeness and any externally visible damage Contact your specialist dealer if the delivery is incomplete or damaged TTT Figure 1 Components included in the scope of delivery Item Quantity Description A 1 SMA Speedwire Webconnect Piggy Back SWPB 10 BG 1 B Installation manual C 1 Cable gland D Silicone tube E 2 Label with PIC and RID for registration in Sunny Portal 10 SPW WebconPB IA en 1 1 Installation Manual SMA Solar Technology AG 4 Product Description 4 Product Description 4 1 SMA Speedwire Webconnect Piggy Back The Speedwire Webconnect Piggy Back is a Speedwire communication interface with Webconnect function for inverters Speedwire is a cable based type of communication based on the Ethernet standard and the communication protocol SMA Data2 This enables inverter optimised 10 100 Mbit data transmission between Speedwire de
23. tion Manual SMA Solar Technology AG 9 Technical Data General Data Mounting location Voltage supply Mechanical Data Width x height x depth Communication Communication interface Maximum cable length Ambient Conditions for Storage Transport Ambient temperature Relative humidity non condensing Maximum height above sea level MSL Installation Manual 9 Technical Data in the inverter via the inverter 50 mm x 81 mmx 12 mm Speedwire Webconnect 100 m 40 C to 70 C 576 to 9576 3 000 m SPW WebconPB IA en 1 1 29 10 Contact 10 Contact If you have technical problems concerning our products contact the SMA Service Line We require the following information in order to provide you with the necessary assistance SMA Solar Technology AG e Type serial number and firmware version of the inverter e Type serial number and firmware version of the Piggy Back e For large scale PV plants serial number and firmware version of the Cluster Controller e For small plants PIC and RID of the Piggy Back Australia Belgien Belgique Belgi Brasil Cesko Chile Danmark Deutschland SMA Australia Pty Ltd Sydney SMA Benelux BVBA SPRL Mechelen Vide Espa a Espanha SMA Central amp Eastern Europe s r O Praha Ver Espa a Se Deutschland Tyskland SMA Solar Technology AG Niestetal Espa a SMA Ib rica Tecnolog a Solar S L U Barcelona France SMA France S A S Lyon 30 SP
24. vices in PV plants The Webconnect function enables data transmission between a small plant and the Internet portal Sunny Portal In Sunny Portal a maximum of four inverters can be combined in a Sunny Portal plant In Italy the Speedwire Webconnect Piggy Back can be used for plants up to 6 kW that are connected to the low voltage grid The Speedwire Webconnect Piggy Back implements grid management for one inverter The Speedwire Webconnect Piggy Back also receives specifications from the network operator via Ethernet in accordance with standard CEI 0 21 The network operator sends the control signals to the Speedwire Webconnect Piggy Back via a network operator gateway The Speedwire Webconnect Piggy Back fulfils the following tasks Setup of a Speedwire network in small and large scale PV plants Data exchange in a large scale PV plant with Cluster Controller via a router network switch Data exchange with Sunny Portal in small plants via a router with Internet connection in large scale PV plants via the Cluster Controller Data exchange with Sunny Explorer Additionally for Italy Implementation of grid management for one inverter Active power limitation of the connected active power Remote shutdown within 50 ms Narrowing of the frequency limits to between 49 5 Hz and 50 5 Hz Automatic narrowing of the inverter frequency limits to between 49 5 Hz and 50 5 Hz when the connection to the network operator gateway is interru
25. wire Webconnect Piggy Back can be used for plants up to 6 kW that are connected to the low voltage grid The Speedwire Webconnect Piggy Back implements grid management for one inverter The Speedwire Webconnect Piggy Back also receives specifications from the network operator via Ethernet in accordance with standard CEI 0 21 The network operator sends the control signals to the Speedwire Webconnect Piggy Back via a network operator gateway The Speedwire Webconnect Piggy Back fulfils the following tasks e Setup of a Speedwire network in small and large scale PV plants Data exchange with Sunny Portal in small plants via a router with Internet connection in large scale PV plants via the Cluster Controller Data exchange with Sunny Explorer Additionally for Italy Implementation of grid management for one inverter Active power limitation of the connected active power Remote shutdown within 50 ms Narrowing of the frequency limits to between 49 5 Hz and 50 5 Hz Automatic narrowing of the inverter frequency limits to between 49 5 Hz and 50 5 Hz when the connection to the network operator gateway is interrupted The Speedwire Webconnect Piggy Back is available as a retrofit kit The inverter still complies with the standard after the product has been installed Installation Manual SPW WebconPB lA en 1 1 7 2 Safety SMA Solar Technology AG The Speedwire Webconnect Piggy Back must only be operated with supported products see
26. y Portal 1 Open www SunnyPortal com 2 Select Plant Setup Assistant M The Plant Setup Assistant opens 3 Follow the instructions of the Plant Setup Assistant 24 SPW WebconPB IA en 1 1 Installation Manual SMA Solar Technology AG 6 Commissioning 6 4 2 Registering a Large Scale PV Plant with Cluster Controller in Sunny Portal Requirements The large scale PV plant with Cluster Controller must be commissioned see Section 6 1 O The inverter with Piggy Back must be in feed in operation The Cluster Controller must be connected to a router with Internet connection see Cluster Controller installation manual Ll Your computer must have an Internet connection Ll JavaScript must be activated in the Internet browser Procedure e For large scale PV plants with Cluster Controller register in Sunny Portal using the Cluster Controller user interface see Cluster Controller user manual Installation Manual SPW WebconPB IA en 1 1 25 7 Decommissioning SMA Solar Technology AG 7 7 1 P O 50 0 Vo oS 7 2 26 Decommissioning Removing the Piggy Back 4 DANGER Danger to life due to electric shock when opening the inverter Lethal voltages are present in the conductive parts of the inverter e Disconnect the inverter from any voltage sources on the AC and DC sides see the inverter installation manual Observe the waiting time to allow the capacitors to discharge Open the inverter see inverter insta