Home

Handbuch User Manual A15-XS - TCI Gesellschaft für technische

image

Contents

1. j O m e E OQO O co oo oO LO N oD N m ep EY E hut Rev 1 0 Ludwig Rinn StraBe 10 14 e D 35452 Heuchelheim GieBen Phone 49 6 41 9 62 84 0 Fax 49 6 41 9 62 84 28 e www tci de Ludwig Rinn StraBe 10 14 e D 35452 Heuchelheim Gie en e Phone 49 6 41 9 62 84 0 Fax 49 6 41 9 62 84 28 e www tci de Seite 25 von 28 Seite 24 von 28 lei lei Raum f r Ihre Notizen this page is intentionally left blank Ludwig Rinn Stra e 10 14 e D 35452 Heuchelheim GieBen e Phone 49 6 41 9 62 84 0 e Fax 49 6 41 9 62 84 28 www tci de Ludwig Rinn Stra e 10 14 e D 35452 Heuchelheim Gie en e Phone 49 6 41 9 62 84 0 e Fax 49 6 41 9 62 84 28 www tci de Seite 26 von 28 Seite 27 von 28 tci GmbH e Ludwig Rinn Stra e 10 14 e D 35452 Heuchelheim Gie en e Tel 49 6 41 9 62 84 0 Fax 49 6 41 9 62 84 28 vertrieb tci de
2. Handbuch User Manual A15 XS Version 1 2 Artikel Nr Part No 11498 lei Inhaltsverzeichnis 1 HAFTUNG COPYRIGHT 2 BEVOR SIE BEGINNEN 2 1 WILLKOMMEN 2 2 SICHERHEIT 3 PRODUKTBESCHREIBUNG 3 1 A15 XS 3 2 STROMVERSORGUNG UND ANSCHL SSE 3 3 MONTAGE A15 XS 3 4 INBETRIEBNAHME ALLGEMEIN 3 5 REINIGUNG UND PFLEGE 3 6 EG KONFORMIT TSERKL RUNG 4 LIEFERUMFANG 5 SUPPORT 5 1 SUPPORT 5 2 R CKSENDUNG 5 3 HERSTELLER GARANTIE 6 TECHNISCHE ZEICHNUNGEN Ludwig Rinn StraBe 10 14 e D 35452 Heuchelheim GieBen Phone 49 6 41 9 62 84 0 e Fax 49 6 41 9 62 84 28 e www tci de Seite 2 von 28 10 12 14 14 16 18 20 20 22 26 List of Content 1 LIABILITY COPYRIGHT 2 BEFORE YOU BEGIN 2 1 WELCOME 2 2 SAFETY 3 PRODUCT DESCRIPTION 3 1 A15 XS 3 2 POWER SUPPLY AND CONNECTIONS 3 3 MOUNTING A15 XS 3 4 COMMISSIONING GENERAL 3 5 CLEANING AND CARE 3 6 EC DECLARATION OF CONFORMITY 4 SCOPE OF DELIVERY 5 SUPPORT 5 1 SUPPORT 5 2 DISPATCH 5 3 MANUFACTURER S GUARANTEE 6 TECHNICAL DRAWINGS lei 11 13 19 15 17 19 21 21 23 26 Ludwig Rinn StraBe 10 14 e D 35452 Heuchelheim Gie en e Phone 49 6 41 9 62 84 0 Fax 49 6 41 9 62 84 28 e www tci de Seite 3 von 28 1 Haftung Copyright Redaktion Copyright Warenzeichen Hinweis Haftung Ludwig Rinn Stra e 10 14 e D 35452 Heuchelheim GieBen e Phone 49 6 41 9 62 84 0 e Fax 49 6 41 9 62 84 28 www tci de
3. Seite 18 von 28 Ludwig Rinn StraBe 10 14 e D 35452 Heuchelheim GieBen e Phone 49 6 41 9 62 84 0 e Fax 49 6 41 9 62 84 28 e www tci de Seite 19 von 28 lci 5 Support 5 1 Support Wir unternehmen im Vorfeld alles um die Funktionsf higkeit unserer Systeme zu ge w hrleisten Sorgf ltige Auswahl der Komponenten aufwendige Tests und Pr fverfahren stellen dies sicher Dennoch kann es zu Ausf llen kommen In einem solchen Fall steht Ihnen unsere Hotline zur Verf gung Wir helfen schnell und unkompliziert Rat und Hilfe bzw Support erhalten Sie unter der 0641 96284 55 support tci de Wir beantworten Ihre Fragen oder l sen Ihre Probleme so schnell wie m glich 5 2 R cksendung Die richtige Verpackung ist der erste Schritt zur problemlosen Versendung eines Ger tes Verwenden Sie ausschlie lich f r Ihre R cksendungen Original Verpackungen von tci darin enthalten sind 2 Inletts und ein Umkarton Sollten Sie keine Verpackung mehr haben wenden Sie sich bitte an unseren Support Unsachgem verpackte und dadurch besch digte Ger te k nnen von der Garantie ausgeschlossen werden wenn die Besch digungen auf die unsachgem e Verpackung zur ckzuf hren ist Wir empfehlen den Versand mit einer Spedition da erfahrungsgem hierbei weniger Sch den entstehen Einen Verpackungshinweis und einen Reparaturschein finden Sie unter www tci de support Ludwig Rinn Stra e 10 14 e D 35452 Heuchelheim Gie en e Phone 49 6 41
4. 9 62 84 0 e Fax 49 6 41 9 62 84 28 www tci de Seite 20 von 28 lei 5 Support 5 1 Support It is our priority to guarantee the functionality of our systems This is ensured by a careful selection of components extensive inspection and test procedure However errors cannot be completely ruled out If you should have any problems with your unit please do not hesitate to contact our hotline We will assist you immediately and without any complications You can reach our Support team at 49 0 641 96284 55 support tci de We will answer your questions or solve any problems you might have with your unit 5 2 Dispatch The right packaging is the first step for a trouble free dispatch of a device Please only use the original tci protective packaging for your returns Devices that get damaged due to improper packaging can be excluded from guarantee We suggest to task a private forwarding agent with the shipment because by our experi ence the devices get less damaged during the transport Further packaging information and a repair form you will find under www tci de support Ludwig Rinn StraBe 10 14 e D 35452 Heuchelheim GieBen e Phone 49 6 41 9 62 84 0 e Fax 49 6 41 9 62 84 28 e www tci de Seite 21 von 28 l amp i 5 3 Herstellergarantie Die tci Gesellschaft f r technische Informatik mbH TCI gew hrt ihrem K ufer eine 12 monatige Produktgarantie auf von TCI hergestellte Produkte Tritt bei einem von TCI hergestell
5. Seite 4 von 28 Florian Schiller Edited by tci GmbH Ludwig Rinn Str 10 14 35452 Heuchelheim Deutschland Copyright Dieses Handbuch sowie die Hard und Software die es beschreibt ist urheberrechtlich gesch tzt und darf ohne ausdr ckliche schriftliche Genehmigung der tci GmbH in keiner Weise vervielf ltigt bersetzt oder in eine andere Darstellungs form gebracht werden Trademark Windows Windows XP embedded und Windows 7 embedded sind eingetragene Warenzeichen der Microsoft Corp Diejenigen Bezeichnungen in dieser Publikation von Erzeugnissen und Verfahren die zugleich Warenzeichen sind wurden nicht besonders kenntlich gemacht Solche Namen sind Warenzeichen der jeweiligen Warenzeicheninhaber Aus dem Fehlen der Markie rung kann nicht geschlossen werden dass diese Bezeichnun gen freie Warennamen sind Note Herausgeber bersetzer und Autoren dieser Publikation haben mit gr ter Sorgfalt die Texte Abbildungen und Programme erarbeitet Dennoch k nnen Fehler nicht v llig ausgeschlossen werden Die tci GmbH bernimmt daher weder eine Garantie noch eine juristische Verantwortung oder Haftung f r Folgen die auf fehlerhafte Angaben zur ckgehen Mitteilungen Uber eventuelle Fehler werden jederzeit gerne entgegengenommen Die Angaben in diesem Handbuch gelten nicht als Zusicherung nn bestimmter Produkteigenschaften nderungen die dem technischen Fortschritt dienen bleiben vorbehalten Die tci Gm
6. concerning errors are welcome at any time The information in this operating manual does not guarantee definite product properties Modifications concerning the support of technical progress will be reserved tci GmbH shall not be held liable for immediate damage occurring in connection with the supply or utilization of the documents In addition we shall not be held liable for any errors found in this publication We are not obliged in any way to update the information contained in this document to latest standards All rights reserved e Printed in Germany Printed on chlorine free bleached Paper Ludwig Rinn StraBe 10 14 e D 35452 Heuchelheim GieBen e Phone 49 6 41 9 62 84 0 e Fax 49 6 41 9 62 84 28 e www tci de Seite 5 von 28 Ci 2 Bevor Sie beginnen 2 1 Willkommen Vielen Dank dass Sie sich f r ein Markenprodukt der Firma tci entschieden haben Auf den folgenden Seiten erhalten Sie grundlegende Informationen Uber das von Ihnen gew hlte Produkt Lesen Sie diese Informationsbroschure bitte sorgfaltig Informationen Uber die eingebauten Komponenten erhalten Sie ber die mitgelieferten Handb cher der einzelnen Hersteller 2 2 Sicherheit Die erste Anforderung an einen Industrie Computer ist Sicherheit Dies steht bei unserem Handeln im Vordergrund Unsere Systeme bieten Ihnen gr tm gliche Sicherheit durch pr zise Fertigung Jedes Ger t wird einem 24h Dauertest unterzo gen und verl sst erst nach einer Abnahme
7. mit Pr fprotokoll unsere Produktion Sicherheit mit System in unseren Produkten und durch die Arbeitsweise unserer Mitarbeiter Das Ger t erf llt die Anforderungen der geltenden EMV Richtlinien und harmonisierten europ ischen Normen sowie RoHS Richtlinie 2002 95 EG Alle von uns an Sie geliefer ten Produkte halten die Anforderungen der REACH Verordnung in der jeweils g ltigen Fassung ein EU Verordnung 1907 2006 EG REACH Unsere Produkte die dem ElektroG entsprechen sind vor dem Inverkehrbringen bei der EAR Elektro Altger te Register durch uns registriert und gekennzeichnet worden Unsere Registrierungsnummer WEEE Reg Nr DE 13433209 Die Betriebsspannung des Ger tes darf nur in den spezifizierten Bereichen liegen Der Kontakt mit Wasser oder anderen Fl ssigkeiten ist zu vermeiden Beachten Sie hierzu die Angaben im Kapitel Produktbeschreibung Beachten Sie bei der Montage eine lot rechte Ausrichtung des Systems zur Wand Das Ger t ist nicht f r den Einsatz im Nuklear und Ex Bereich geeignet Ein Verdecken der L ftungsschlitze kann zu tempera tur bedingten Defekten f hren Vor dem ffnen des Geh uses den Netzstecker ziehen Wir w nschen Ihnen viel Freude mit Ihrem neu erworbenen Ger t Ihr tci Team Ludwig Rinn StraBe 10 14 e D 35452 Heuchelheim Gie en Phone 49 6 41 9 62 84 0 Fax 49 6 41 9 62 84 28 e www tci de Seite 6 von 28 lci 2 Before you begin 2 1 Welcome Thank you for choosing a tci pr
8. von Austauschteilen die einem besonderen Verschlei unterliegen von Ver brauchsmaterial und von Datentr gern Instandsetzung von Zubeh r nderungen Anbauten oder sonstigen Einrichtungen die nicht von tci geliefert wurden Instandsetzungsarbeiten wenn die Umge bungs bedingungen It der Dokumentation nicht eingehalten wurden M ngel die durch mangelhafte Systemausle gung Systemkonfiguration und Montageart durch den Betrieb unter ungeeigneten Umge bungsbedingungen oder sonstigen ungeeig neten Betriebsmethoden durch ungeeignete Wartung oder ungeeig nete Tests oder durch Einfl sse wie Verunreinigungen bedingt sind Ludwig Rinn Stra e 10 14 e D 35452 Heuchelheim Gie en e Phone 49 6 41 9 62 84 0 e Fax 49 6 41 9 62 84 28 e www tci de Seite 22 von 28 3 The voucher of the purchase has to be submitted third party or any other external influence TCI 4 External factors e g fire vandalism unau can not be held responsible for thorized handling excessive temperatures 2 Costs of replacement parts subject to etc or normal wear are excluded from the extreme wear and of consumables and data guarantee carriers 5 The product must not have been modified ex 3 Maintenance or repair of accessories modi cept by authorized TCI employees or partners fied parts added parts or any other part that 6 The product has been used exclusively in a have not been delivered by TCI competent way according to the op
9. 0 14 e D 35452 Heuchelheim Gie en e Phone 49 6 41 9 62 84 0 e Fax 49 6 41 9 62 84 28 www tci de Seite 8 von 28 l amp i 3 Product Description 3 1 A15 XS Maintenance free embedded HMI touch with ultraflat design The embedded HMI touch is developed for universal employment in your industrial applications The system with the ARM Prozessor offers you a economical basis for your application The integrated touch display is 15 in size Maintenance free and energy saving The A15 XS turns out to be particularly rugged in daily use Without moving parts such as fans and hard disks the system is maintenance free and suitable for the 24h conti nuous operation With the anodized aluminium front that suits the protection class IP 65 you can even use the computer in rugged industrial environment permanently Display A15 Type 15 Touch Resolution 1024 x 768 Pixel Norm at least ISO 13406 2 class ll Surface Resistant against chemical agents and solvents Acetone Methylene Chloride Methyl Ethyl Ketone Isopropyl Alcohol Hexane Turpentine Mineral Oil Unleaded Gasoline Diesel Fuel Motor Oil Transmission Fluid Antifreeze Fluid Specifications Environmental Operating temperature 0 C to 50 C conditions Relative humidity 10 to 90 non condensing Storage conditions Storage temperature range 20 C to 70 C Humidity 5 to 95 non condensing Ludwig Rinn Stra e 10 14 e D 35452 Heuchelheim Gie en e Phone 4
10. 10 14 35452 Heuchelheim Gie en Weitergehende Anspr che insbesondere Schadensersatzanspr che sind von der Garantie nicht umfasst Die gesetzliche M ngelhaftung bleibt von der Garantie unber hrt Es gilt das Recht der Bundesrepublik Deutschland unter Ausschluss des UN Kaufrechts Ist der Kunde Kaufmann ist Gerichtsstand f r Streitigkeiten aus dieser Garantie der Sitz von TCI Voraussetzungen f r Garantieleistungen Nicht von der Garantie umfasst 1 Es handelt sich um einen Mangel der nach 1 Ma nahmen zur Beseitigung von St rungen dem Kauf entstanden ist die auf Bedienungsfehlern sonstiger unsach 2 Das betreffende Produkt ist ber die Serien gem er Behandlung technischen Eingriffen nummer eindeutig identifizierbar seitens des K ufers oder Dritter oder auf lei 5 3 Manufacturers Guarantee tci Gesellschaft f r technische Informatik mbH TCI provides a 12 month product guarantee to the purchaser which covers products manufactured by TCI Should a defect be determined with a product manufactured by TCI within 12 months after delivery then TCI will remove this defect at their own option either by providing a new product or by replacing parts or by repairing the product subject to the conditions defined below Within the scope of the guarantee TCI will bear all costs related to the replacement of parts or the repair of products or product parts during the term of this guarantee insofar as the defect has oc curred duri
11. 9 6 41 9 62 84 0 e Fax 49 6 41 9 62 84 28 www tci de Seite 9 von 28 lci l amp i 3 2 Stromversorgung und Anschl sse 3 2 Power supply and connection Function key Function key 18V 48V DC 18V 48V DC LAN LAN Achten Sie beim Anschluss der Spannungsver Pay attention to the correct polarity when sorgung auf die richtige Polung connecting the power supply Ludwig Rinn Stra e 10 14 e D 35452 Heuchelheim Gie en e Phone 49 6 41 9 62 84 0 e Fax 49 6 41 9 62 84 28 e www tci de Ludwig Rinn Stra e 10 14 e D 35452 Heuchelheim Gie en e Phone 49 6 41 9 62 84 0 e Fax 49 6 41 9 62 84 28 www tci de Seite 10 von 28 Seite 11 von 28 Ci 3 3 Montage A15 XS So gehen Sie bei der Montage vor Achten Sie auf fachgerechte Montage durch autorisiertes Fachpersonal Das Ger t muss von der Stromversorgung getrennt und damit Spannungsfrei sein 1 Legen Sie nach dem Auspacken das Ger t mit der Front auf ein Innenteil der Verpackung Damit sch tzen Sie das Geh use vor Besch digung 2 Nehmen Sie den Ausschnitt und die Bohrungen gem Angaben im Abschnitt Technische Zeichnungen vor 3 Setzen Sie das Ger t fl chenb ndig in Ihren Ausschnitt ein Achten Sie auf korrekten Sitz der Dichtungen da sonst die angegeben Schutzklasse nicht erreicht werden kann Ziehen Sie nun mit geeigneten Muttern gleichm ig und ber Kreuz an A15 XS Max Drehmoment 3 6 Nm bei Aluminiumfront Sie erkennen den optimalen Sitz daran dass d
12. bH haftet nicht f r unmittelbare Sch den die im Zusammenhang mit der Lieferung oder dem Gebrauch der Dokumentation stehen Wir haften zudem auch nicht f r etwaige Fehler in dieser Publikation Wir verpflichten uns in keiner Weise die in dieser Dokumentation enthaltenen Informationen auf den aktuellsten Stand zu bringen oder auf dem neuesten Stand zu halten Alle Rechte vorbehalten e Printed in Germany Gedruckt auf chlorfrei gebleichtem Papier lei 1 Liability Copyright Florian Schiller tci GmbH Ludwig Rinn Str 10 14 D 35452 Heuchelheim Germany This manual as well as the hard and software which it describes is protected by copyright and may not be duplicated translated or presented in any form without the written consent of tci GmbH Windows Windows XP embedded and Windows 7 embedded are registered trademarks of Microsoft Corp Those designation of products and procedures in this publication which are also trademarks have not been expressly stated as such These names are trademarks of the respective trademark owners However the absence of the symbol implies in no way that the designations are exempt from such rights Publisher translators and authors of this publication have carefully developed the texts illustrations and programs However errors can not be completely ruled out tci GmbH shall neither warrant nor be held legally responsible for consequences which occur due to incorrect data Information
13. bed in this manual A15 XS hereby the agreement with regulations of the following EC guidelines is confirmed EMC directive 2004 108 EG RoHs directive 2011 65 EU Low voltage directive 2006 65 EG To evaluate the electromagnetic compatibility of these products the following standards were taken into consideration EN 55022 2010 class A EN 55024 2010 EN 61000 6 2 2005 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2013 To evaluate the electrical safety the following standards were taken into consideration EN 60950 1 2006 A11 2009 A1 2010 A12 2011 A2 2013 To evaluate the RoHs requirements the following standards were taken into consideration EN 50581 2012 only with devices with 230 VAC internal This declaration is made under the sole responsibility of the producer tci Gesellschaft f r technische Informatik mbH Ludwig Rinn Stra e 10 14 35452 Heuchelheim The Management Heuchelheim 19th August 2014 Ludwig Rinn StraBe 10 14 e D 35452 Heuchelheim Gie en e Phone 49 6 41 9 62 84 0 Fax 49 6 41 9 62 84 28 e www tci de Seite 17 von 28 lei lei 4 Lieferumfang 4 Scope of delivery e A15 XS e A15 XS e Netzanschlussstecker e Power supply plug e Handbuch e Operating manual e Handbuch XS Technologie e Operating manual XS Technology Ludwig Rinn StraBe 10 14 e D 35452 Heuchelheim GieBen e Phone 49 6 41 9 62 84 0 e Fax 49 6 41 9 62 84 28 e www tci de
14. erating 4 Repair work that has become necessary manual and documentation because the limits of the environmental spe 7 Installation operation repair and maintenance cifications in the documentation have been have been performed according to the instructions exceeded and the operating documentation the purchaser 5 Defects that have resulted from an inadequate has obtained from TCI This means in particular a Installation setup and mounting have been performed according to the installation and operating instructions in the documentation and by a competent professional b Necessary repair work during the term of guarantee has been performed exclusively by a TCI employee or authorized partner or with spare parts provided by TCI c The product concerned has been used exclusively in connection with compatible products system layout system configuration and type of mounting or from operation under inappro priate environmental conditions or from other inappropriate operating methods or from incompetent maintenance or inappropriate tests or from influences like contamination Ludwig Rinn StraBe 10 14 e D 35452 Heuchelheim GieBen e Phone 49 6 41 9 62 84 0 e Fax 49 6 41 9 62 84 28 e www tci de Seite 23 von 28 l amp i 6 Technische Zeichnung Technical Drawing Frontansicht Seitenansicht Einbauma R ckansicht Side view Mounting hole Rear view Front view A30 mm 70 mm 63 mm 280 mm 63 mm lt lt lt ee
15. ie r ckseitig in die Front eingelegte Dichtung seitlich nicht mehr sichtbar ist Dann nicht mehr weiter anziehen da die Gefahr besteht dass das zul ssige max Drehmoment berschritten wird und der Bolzen bzw die Front besch digt werden Ludwig Rinn StraBe 10 14 e D 35452 Heuchelheim Gie en Phone 49 6 41 9 62 84 0 e Fax 49 6 41 9 62 84 28 e www tci de Seite 12 von 28 lci 3 3 Mounting A15 X For mounting the A15 XS please follow the instructions below The device should only be mounted by authorized staff Furthermore it must be disconnected from mains so that it is de energized 1 After unpacking first put the unit with its surface on one of the inner parts of the packaging So you may protect the chassis from damage 2 Now cut out the wall and drill the holes in accordance with the information given in chapter technical drawing 3 Insert the device into the mounting hole so that the surface fits flush with the adjacent areas Pay attention to the correct seat of the seals as otherwise the indicated pro tection class cannot be achieved Now tighten the screws evenly and crosswise with suitable nuts A15 XS Max Torque 3 6 Nm with aluminium front You can recognize the optimal seat by the fact that the back mounted seal of the front cannot be seen anymore Stop tightening the screws now Exceeding the permissible torque may damage the pin respectively the front Ludwig Rinn StraBe 10 14 e D 35452 Heuchelhe
16. im Gie en e Phone 49 6 41 9 62 84 0 Fax 49 6 41 9 62 84 28 e www tci de Seite 13 von 28 l amp i 3 4 Inbetriebnahme allgemein Software XS XS Technologie beschreibt Systeme die ohne Betriebssystem auskommen und mit Microbrowser von ininet ausgestattet sind weitere Schritte finden Sie im Handbuch 9694 XS Technologie 3 5 Reinigung und Pflege Sofern das System ohne L fter und Filtermatten ausgeliefert wurde ist es wartungsfrei Zur Reinigung des Touches bitte folgendes beachten Auf dem Desktop bzw auf dem mitgelieferten Datentr ger befindet sich eine Software mit dem Namen Touchblocker Durch diese Software wird der Touch f r 60 Sekunden blockiert In dieser Zeit haben Sie die M glichkeit den Touch mit einem weichen Tuch ohne Reinigungsmittel zu s ubern Ludwig Rinn StraBe 10 14 e D 35452 Heuchelheim Gie en Phone 49 6 41 9 62 84 0 Fax 49 6 41 9 62 84 28 e www tci de Seite 14 von 28 lci 3 4 Commissioning general Software XS XS technology describes systems without an operating system and equipped with a microbrowser from iniNet For further information please see the manual 9694 XS technology 3 5 Cleaning and care If the system is delivered without a fan or a filter pad it is maintenance free For cleaning the touch please note that On the desktop or the provided data storage you will find a software named touchblocker With this software the touch display will be blocked for 60 sec Withi
17. n this period you can clean the display with a soft cloth without cleaning agents Ludwig Rinn StraBe 10 14 e D 35452 Heuchelheim Gie en e Phone 49 6 41 9 62 84 0 Fax 49 6 41 9 62 84 28 www tci de Seite 15 von 28 l amp i 3 6 EG Konformit tserkl rung F r das folgend bezeichnete Erzeugnis A15 XS wird die bereinstimmung mit Bestimmungen der nachstehenden EG Richtlinien best tigt EMV Richtlinie 2004 108 EG RoHs Richlinie 201 1 65 EU Niederspannungsrichtlinie 2006 65 EG Zur Beurteilung der elektromagnetischen Vertr glichkeit des Erzeugnisses wurden folgende Normen herangezogen EN 55022 2010 Klasse A EN 55024 2010 EN 61000 6 2 2005 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2013 Zur Beurteilung der elektrischen Sicherheit wurden folgende Normen herangezogen EN 60950 1 2006 A11 2009 A1 2010 A12 2011 A2 2013 Zur Beurteilung der RoHs Anforderungen wurden folgende Normen herangezogen EN 50581 2012 nur bei Ger ten mit 230 VAC intern Diese Erkl rung wird verantwortlich f r den Hersteller tci Gesellschaft f r technische Informatik mbH Ludwig Rinn Stra e 10 14 35452 Heuchelheim abgegeben durch die Gesch ftsleitung Heuchelheim 19 08 2014 Ludwig Rinn StraBe 10 14 e D 35452 Heuchelheim Gie en Phone 49 6 41 9 62 84 0 e Fax 49 6 41 9 62 84 28 e www tci de Seite 16 von 28 3 6 EC Declaration of Conformity The product descri
18. ng proper use of the product Any costs incurred for the determining of the defect as well as costs of mounting and demounting at the customer s premises are to be borne by the purchaser Delivery and dispatch of products or product parts will be effected at the purchaser s risk and expen se The term of guarantee shall begin from the date of delivery of the product Any services provided within the scope of the guarantee do not extend the term of guarantee All products or product parts delivered as or for a replacement are new or equivalent to new and in perfect operative condition replaced products or product parts will become property of TCI as soon as they are sent off to or collected by TCI the purchaser guarantees that there are not any legal im pediments to such transfer of product and ownership which might result from third party rights Any claims under this guarantee are to be made to TCI in writing within one month after cognizance of the defect Current address tci Gesellschaft f r technische Informatik mbH Ludwig Rinn Strasse 10 14 35452 Heuchelheim Giessen Germany Any further claims claims for damages in particular are excluded from this guarantee Statutory liability for defects remains unaffected of this guarantee The German law shall apply to all matters related to this guarantee In case the purchaser is a mer chant place of jurisdiction for any litigation resulting from this guarantee shall be the location of the regis
19. oduct On the following pages you will find fundamental information about the product you have chosen Please read the information brochure carefully The operating manuals provided by the individual manufacturers contain Information on the built in components 2 2 Safety The first demand on an industrial computer is safety This is our first priority Apart from safety achieved by precise production we offer our systems with a 24h endurance test and acceptance with inspection reports A systematic approach to safety in our products and in the way our employees work The unit fulfils the valid requirements of EMC directives and harmonized European standards also RoHS Directive 2002 95 EC All products according the requirements of the current REACH Regulation EU REACH Regulation 1907 2006 EC Before marketing our products according to the ElektroG are registrated and labeled by the EAR Elektro Altger te Register Our registration number WEEE Reg No DE 13433209 The operating voltage of the unit is to be confined within the specified ranges Do not let the unit encounter water or other liquids In addition to that issue please note the chapter Product description Please attend that the chassis must be mounted perpendicular to the wall The product is not usable for nuclear areas and Ex areas Covering the ventilation slots can lead to defects caused by overheating Pull the power plug before opening the housing We hope you
20. ten Produkt innerhalb von 12 Monaten nach Lieferung ein Mangel auf wird TCI diesen unter nachgenannten Voraussetzungen nach eigener Wahl entweder durch Liefe rung eines Neuger tes Austausch von Teilen oder durch Reparatur beseitigen TCI tr gt im Rahmen seiner Garantieleistungen w hrend der Garantiezeit die mit dem Austausch oder der Reparatur von Produkten oder Produktteilen verbundenen Kosten soweit der Mangel im Rahmen einer ordnungsgem en Nutzung der Produkte aufgetreten ist Die Kosten zur Feststellung des Man gels beim K ufer sowie des Ein oder Ausbaus sind vom K ufer zu tragen Transport und Versand von Produkten oder Produktteilen erfolgen auf Gefahr und Kosten des K ufers Garantiezeiten beginnen jeweils mit dem Tag an dem die Lieferung des Produktes erfolgt Die Erbrin gung von Garantieleistungen verl ngern die Garantiezeiten nicht Die im oder zum Austausch gelieferten Produkte oder Produktteile sind neu oder neuwertig und in einwandfreiem funktionst chtigem Zustand ausgetauschte Produkte oder Produktteile werden mit Absendung durch TCI oder Abholung der entsprechenden Austauschteile bei TCI deren Eigentum der K ufer garantiert dass Rechte Dritter diesem Austausch und Eigentums bergang nicht im Wege stehen Anspr che aus dieser Garantie sind innerhalb von einem Monat ab Kenntnis des Mangels schrift lich bei TCI anzumelden Derzeitige Anschrift ist tci Gesellschaft f r technische Informatik mbH Ludwig Rinn Stra e
21. tered office of TCI Terms of guarantee Excluded from this guarantee are 1 Only defects that have occurred after the 1 All measures for the removal of defects that purchase are covered by this guarantee have been caused by operating mistakes 2 The product in question must be clearly iden other incompetent handling technical inter tifiable by its serial number vention on the part of the purchaser or any 3 Vorlage des Kaufbelegs AuBere Faktoren wie z B Brand Vanda lismus nicht autorisierte Eingriffe zu hohe Temperaturen etc oder normaler Verschlei sind als Ursache ausgeschlossen Das Produkt wurde nicht ver ndert ausge nommen von autorisierten TCI Mitarbeitern Partnern Das Produkt wurde ausschlie lich sachgem entsprechend der Bedienung sanleitung und Dokumentation angewendet Die Installation Bedienung Reparatur und Wartung erfolgt gem den von TCI zur Ver f gung gestellten Vorgaben Dies bedeutet im Einzelnen a Installation Aufbau und Montage erfolgen gem der Bedienungs und Montageanlei tung und durch eine entsprechende Fachkraft b Eine im Garantiefall notwendige Reparatur wird ausschlie lich von einem TCI Mitarbeiter Partner oder mit von tci zur Verf gung gestell ten Ersatzteile durchgef hrt c Das betreffende Produkt wird ausschlie lich in Verbindung mit kompatiblen Produkten angewendet u eren nicht von TCI zu vertretenden Ein fl ssen beruhen Kosten
22. will enjoy your new unit your tci team Ludwig Rinn StraBe 10 14 e D 35452 Heuchelheim Gie en Phone 49 6 41 9 62 84 0 Fax 49 6 41 9 62 84 28 www tci de Seite 7 von 28 l amp i 3 Produktbeschreibung 3 1 A15 XS Wartungsfreier Embedded HMI Touch Der embedded HMI Touch wurde f r den universellen Einsatz in Ihren industriellen Anwen dungen entwickelt Das System bietet Ihnen mit dem ARM Prozessor eine kosteng nstige Basis f r Ihre Applikationen Die Gr e des integrierten Touch Displays betr gt 15 Wartungsfrei und energiesparend Das A15 XS System zeigt sich im t glichen Einsatz besonders robust Ohne drehende Teile wie L fter und Festplatte ist das System wartungsfrei und f r den 24h Dauerbetrieb geeignet Mit der eloxierten Aluminium Front in Schutzart IP 65 k nnen Sie den Rechner auch in rauer Industrie Umgebung dauerhaft einsetzen Display A15 Typ 15 Touch Aufl sung 1024 x 768 Pixel Norm mindestens ISO 13406 2 Klasse II Oberfl che Resistent gegen chemische Stoffe und L sungsmittel Azeton Methyl chlorid Ethanol Isopropanol Hexan Terpentin Mineral l Bleifreies Benzin Motoren l Diesel Getriebe l und Frostschutzmittel Spezifikationen Umgebungs Betriebstemperatur 0 C bis 50 C bedingungen Relative Luftfeuchtigkeit 10 bis 90 nicht kondensierend Lagerbedingungen Lagertemperatur 20 C bis 70 C Luftfeuchtigkeit 5 bis 95 nicht kondensierend Ludwig Rinn Stra e 1

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書ダウンロード(PDF)  Sony CDX-4180FP Operating Instructions  User Manual  LPガスバルク供給ヒヤリ・ハット事例集(平成15年度  Sun StorEdge S1 Array Installation and Maintenance Manual    取扱説明書 - Xtrons  Magnavox VRX344AT Owner's Manual  Toro 340 User's Manual  Allegato E - IREN Energia  

Copyright © All rights reserved.
Failed to retrieve file