Home

User manual

image

Contents

1. Industrielle Automation D al ef 6 D en Pa G Ii DAC St gan E E gt User manual BLCDN 4M12S 4Al VI Edition 2011 3 15 Compact BLCDN 4M12S 4Al VI Industr A Edition 2011 3 15 All brand and product names are trademarks or registered trade marks of the owner concerned Hans Turck GmbH M lheim an der Ruhr All rights reserved including those of the translation No part of this manual may be reproduced in any form or processed duplicated or distributed by means of electronic systems without written permission of Hans Turck GmbH amp Co KG M lheim an der Ruhr Subject to alterations without notice 2 32011 Hans Turck GmbH amp Co KG e D 45472 M lheim an der Ruhr e Witzlebenstra e 7 e Tel 0208 4952 0 e Fax 0208 4952 264 e more turck com e www turck com Edition 2011 3 15 Compact BLCDN 4M12S 4Al VI ee A 1 General Sale ul EE 4 I Before the W 11 ah Oh idea wait kwa eu wi wet aa e ia tt kk e e a n iiaa Geng a ki ar a aia e e e ky ka n n tak n td w aaa 4 2 General EE 5 2 1 Description of symbols Used sssss essen 5 See 5 2 3 Notes Concerning Planning Installation of this Product ssss sss titit sese seene enen 5 3 ANNO OU CO 1 BN 6 3 1 BL compact High signal variety in a compact desidn cssssssss sss esse esse esse aaa ense 6 A VOCMMIC AN ATA sasanak baik aaa ti t dw oye e et a e k kn ta BANG a Pa a Ak ak k kap KA ab d a one ia ka ae 7 Fieldbus and IJO CONN G
2. 2 bytes IL MAP polled iro 0 bytes I MAP summariz 0 bytes I MAP schedule 0 bytes COS MAP COS 0 bytes Q MAP GW cont 2 bytes Q MAP polled o 0 bytes slot count 0 dat 1 BLC 8X5G PD FMPTY RASF LZ L Abbrechen Ubemehmen Hite A ILIIIG Gr Ok P Gr fie N Gr DA v Fi H A b M Graph Spreadsheet Master Slave Configuration A Diag gt Message Code Date Description A onet 0005 lt 07 07 2008 10 12 51 Hans Turck GmbH amp Co KG BLCDN 6 6 Vendor Specifc Classes VSCs BL compact modules for DeviceNet are based on the communications adapter profile according to ODVA specifications Rel V2 0 ODVA Open DeviceNet Vendor Associa tion NOTE Copy protection activation for RSNetWorx was not detected The software will run in DEMO Mode Offline Besides the standard DeviceNet classes this module supports the following Vendor Specific Classes VSC 100 64h Gateway Class 101 65h Terminal Slot Class 102 66h Process Data Class VSCs for the respective I O channels 10 32011 For more detailed information about the PLC configuration of TURCK DeviceNet products or the Vendor Specific Class es of the I O channels please read for example the respective BL67 manual D300528 pdf which can be downloaded from www turck com Hans Turck GmbH 8 Co KG e D 45472 M lheim an der Ruhr e Witzlebenstrake 7 e Tel 0208 4952 0 e Fax 0208 4952 264 e
3. 2 2 Prescribed Use Appropriate transport storage deployment and mounting as well as careful operating and thorough maintenance guarantee the trouble free and safe operation of these devices WARNING The devices described in this manual must be used only in applications prescribed in this manual or in the respective technical descriptions and only with certified components and devices from third party manufacturers 2 3 Notes Concerning Planning Installation of this Product WARNING All respective safety measures and accident protection guidelines must be considered carefully and without exception 5 32011 Hans Turck GmbH amp Co KG e D 45472 M lheim an der Ruhr e Witzlebenstrae 7 e Tel 0208 4952 0 e Fax 0208 4952 264 e more turck com e www turck com Edition 2011 3 15 Compact BLCDN 4M12S 4Al VI Industr A 3 Introduction 3 1 BL compact High signal variety in a compact design For the first time BL compact provides a product family of IP67 fieldbus devices that can meet any requirement in the I O level in terms of signal type and connectivity Until now compact fieldbus stations were applied to process only digital fieldbus signals BL compact now allows a wide range of I O tasks to be implemented outside of the control cabinet in a compact design with virtually any signal combination The basic concept With the modular concept of the BL67 system by TURCK a fieldbus node can be installed outside the
4. rate detection The bit rate can be changed via the standard ODVA DeviceNet Class Class 0x03 In stance 0x01 Attribute 0xx02 Terminating resistor female 6 3 Field bus termination If the module is used as the first or the last sta tion in the bus communication the fieldbus line has to be terminated using a terminating resis tor The module offers no internal bus terminating resistor The termination has to be done exter nally 6 4 Service interface In order to connect the service interface on the module with a PC and the I O ASSISTANT soft ware project planning and diagnostics soft ware a cable with a pin assignment different from the PS2 standard pin assignment has to be used vllo vllo e W Yo dean dean N e 0000o Service Industr A module restart RKE57 TR2 Ident no 6602629 Terminating resistor male RSE57 TR2 Ident no 6602308 9 32011 Hans Turck GmbH amp Co KG e D 45472 M lheim an der Ruhr e WitzlebenstraRe 7 e Tel 0208 4952 0 e Fax 0208 4952 264 e more turck com e www turck com Edition 2011 3 15 Compact BLCDN 4M12S 4Al VI 6 Commissioning 6 5 PLC configuration a File Edit View Network Device Diagnostics Tools Help The modules can be integrated into the De viceNet structure by means of module specif ic BL compact EDS files Commissioning in a configuration tool Registrate the EDS files in the PLC configura tion tool eg in RSNetWorX
5. 0 0 1 2008 01 24 1 0 0 1 2007 10 10 1 0 0 1 2007 10 10 1 0 0 2007 10 10 1 0 0 2007 10 10 1 0 0 2008 11 06 1 0 0 2008 11 06 and maintenance The I O ASSISTANT and the DTMS are avail able free of charge on www turck com Software functions m Supporting software tool m Configuration parameterization and com missioning of BL Compact modules vi a DTM technology m Import of BL Compact DTM files m Offline planning and configuration of BL67 BL20 and BL compact I O modules m Reading and setting of process data m Commissioning help for testing the wiring and sensors without PLC m Automatic documentation of configured TURCK systems 11 32011 D lt FixModData FWDownbadFile binary FWDOownloadBinanyStartw 65536 FWWait DWL SODO Progld gw8lDtm Mainz gt Hans Turck GmbH 8 Co KG e D 45472 M lheim an der Ruhr e Witzlebenstrake 7 Tel 0208 4952 0 e Fax 0208 4952 264 e more turck com e www turck com Edition 2011 3 15 Compact BLCDN 4M12S 4Al VI Industr A 8 LED description 8 1 Stations LED Status Eo elur es eege O OC oO C EE emmer C C S S SCSCS RED JON Yow power orstation enor SS RED FLASHING THz JO module configuration error RED JELASHING 4 H2 No VO module bus communication Jemen Jo station ok Jemen SLASHING Fosmoeshe Ti ws O o ooo il Ti enne FLASHING 1 Hz One or more I O in Idle State One or more UO error FLASHING One or
6. HO NS ii oka a ot a kl p ke eee a n e a io a nn it ai an kn kem a 8 Dal Tar snd Wining Re ON ANN asia kk ajaa w kl a ak dg ap pate a A A m n ee fk a a kk e a a kk 8 6 COMNUSSIONID Le n nt ia ees ank e a se nes jana ei oe se e ki n k e es e e kf n n a l s n pinn e 9 51 Address S LING D 9 62 SEMIS NE fr AN E TER E 9 6 3 TENGU DUS TENN T E 9 6 4 Service Mer To eke ia a ia ra dia ad a ina a tk e et ot a et e e at ee n e a at e a a a kn e ti e a eee ee e e ere 9 69 PEG GONN UNION eee nee ve etan le ei ali mot ei il kry ajah a ji fi el ala a a a a e a a e a aaa ada a a aja a Bana ka a re aana ka a kn 10 OG VENGOr Specife Classes V SE Jussara el aa a a ea a baa aa t a aj alan ki a Bana aa ki a aa a En ee an a a anana ak a al e lb a l 10 DT OS TAN H RE 11 al 2 51 1531 d 11 S LED Lol eie ME 12 DL Sons LED NS ii a kaginaaken ag tie E E a nga aana aa a a ae la aaa r k tr ep a kk a brik ad aa asa 12 D2 NO EED E 12 H Mapping and dIaQgnNOStICS h0 L9 til kte kaa sese sees sese eee 13 9 1 I O and Diagnostic Data mappingd ccsss sss ss sssss sese sees eenn neee 13 9 2 AAI VI Diagnostic messages ssanuruanenennannnnane kann kana eenn 13 10 eu 14 10 1 JDEVICENGT Param TE 14 102 7 5 VI al MO CE L a kri w dye etni as td a a da a akak Wah anara kt kn an a Ga P GA a a Bg karana anaa krana kd an a api pa ii ey 14 3 32011 Hans Turck GmbH amp Co KG e D 45472 M lheim an der Ruhr e WitzlebenstraRe 7 e T
7. V 2 0VM 10 V 3 OmA 20 mA 4 4 mA 20 mA Parameter for setting the type of values representation for the respective channel 0 default 1 16 bit integer 2 12 bit left justified diagnostics 0 channel 1 3 channel 4 Hans Turck GmbH 8 Co KG e D 45472 M lheim an der Ruhr e Witzlebenstra e 7 e Tel 0208 4952 0 e Fax 0208 4952 264 e more turck com e www turck com
8. control cabinet using any signal combina tion For this purpose passive base and active electronic modules are connected to fieldbus gateways which fulfill application specific I O tasks Such a fieldbus node can take one gateway with up to 32 extension modules max 512 I O points For applications with low signal density and limited mounting space BL compact is an efficient alternative because basically all BL67 I O signals are also available in BL compact The modular principle The BL compact devices provide three basic functions in a single housing Fieldbus connection I O signal and connector Depending on the housing style one or two I O modules can be housed The smaller versions e g M12S and M12MT can link any BL67 electronic module each to PROFIBUS DP or DeviceNet The bigger versions e g M12LT have space for two BL67 electronic modules making the possibilities of signal combination nearly infinite v k f wa bah ra m ra ta Ea NO NO Ei GA A E f gt NM NOTE The O system BL compact does not require mounting in an extra housing It was specially designed for the harsh industrial en vironment and for direct mounting on the machine and in the process The system is extremely robust and protected against dirt dust and the most liquids through its high degree of protection However it is not suited for the following applications high pres sure jet cleaning 100 humidity out door installation or permanent
9. from Rockwell Au tomation The BL compact modules can now be found under TURCK Inc gt Communication Adapter Add the modules to your fieldbus line The EDS files can be downloaded from www turck com DA FAS SCS SUC SA SRR FE AF AE AF AP AS AS SSS A CELLIER DeviceNet Z Category AC Drive Barcode Scanner Communication Adapter DPI to DeviceNet DSI to DeviceNet DeviceNet Safety Scanner DeviceNet to SCANport Dodge EZLINK General Purpose Discrete UO Generic Device Human Machine Interface Inductive Proximity Switch Limit Switch Motor Overload Motor Starter Photoelectric Sensor PointBus Motor Starter Rockwell Automation miscellaneous SCANport Adapter Safety Controllers Safety Discrete I O Device Smart MCC Speciaty LO Vendor Rockwell Automation Allen Bradley Rockwell Automation Dodge Rockwell Automation Electro Craft Motion Control Rockwell Automation Relance Electric Rockwell Automation Ertek Ird Intl Rockwell Automation Sprecher Schuh Turck Inc Communication Adapter d BL20 E GW ON acon Industr A BL20 E GW DN BLCDN 00 01 BLCDN Ax General Parameters 1 0 Data EDS Fie Select the parameter that pou want to configure and initiate an action using the toolbar T Groups e zg K a M P Parameter Current Value Z Z GWscheduledd disabled Z Z COS data mapping standard Baud Rate 125 kbps AutoBaud dsabled I MAP GW statu
10. more lO in Faulted State 8 2 I O LED Status Ip on on on eege O O OC O No diagnostics active ON staton error module bus communication failure FLASHING 0 5Hz Any diagnostics active FLASHING 0 5 Hz Underflow in measuring range FLASHING 4 Hz Overflow in measuring range D LED also reports gateway diagnostics 12 32011 Hans Turck GmbH amp Co KG e D 45472 M lheim an der Ruhr e Witzlebenstrafe 7 e Tel 0208 4952 0 e Fax 0208 4952 264 e more turck com e www turck com Edition 2011 3 15 Compact BLCDN 4M12S 4Al VI Industr A 9 Mapping and diagnostics 9 1 I O and Diagnostic Data mapping INPUT BYTE Ier Bits DS Di Bits Di Di Bit emo p mos n os As na CUES O p ave mz ET SSS y E E n 8 om Module bouk pe diagnostic data e ente Diag Reserved station active Reserved Measuring Range Exceeded Ch 1 11 Reserved Measuring Range Exceeded Ch 2 12 Reserved Measuring Range Exceeded Ch 3 13 Reserved Measuring Range Exceeded 9 2 4AI VI Diagnostic messages Diagnostic message Meaning Range error CH x The measurement range has been exceeded The threshold is 1 of the positive measurement range end value In current mode an underflow diagnosis is only invalid for the value range 4 20 mA 13 32011 Hans Turck GmbH 8 Co KG e D 45472 M lheim an der Ruhr e WitzlebenstraG3e 7 e Tel 0208 4952 0 e Fax 0208 4952 264 e more turck com e www turck com Edition 2011 3
11. more turck com e www turck com Edition 2011 3 15 Compact BLCDN 4M12S 4Al VI 7 The I O ASSISTANT The configuration software I O ASSISTANT supports you in planning and implementation of an I O system No matter if you are online or offline the soft ware simplifies the configuration and parame terizsation of the modules The I O ASSISTANT is also extremely helpful in system set up and P PACTware O1 Intern 4Al V I Parameterization File Edt View Project Device Extras Window Help O94 8200 Bag Ba Gen 1 BLCDN 4M125 4A1 VI nee O1fIntern 4Al V l L BLCDN 4M125 8x5G PO testing 5 res Yendor BL Service BL67 fk Turck 7 1 FDT DTM BL Service BL67 Mk Turck BL Service BL Servi Turck BL Service E Servi Turck BL Service BL Servi Turck BL Service 6 Servi Turck BL Service BL Servi Turck BL Service BL Servi Turck BL Service P Servi Turck BL Service BL Servi Turck The system configuration parameterization and diagnostics are done via graphical interfaces based on FDT DTM technology The DTMs can be integrated in any FDT frame application for configuration commissioning ELCDON 4M125 4AI VI BLCDN 4M125 8X5G PD BL Service BLC Mo Turck BL Service BLC Mo Turck Ur GP L Se Value DTM specific DTM specfic ogue inputs Industr A Offline parameterization i x Device Version Aa 1 0 0 1 2007 10 10 1 0 0 2007 10 10 1 0 0 1 2007 10 10 1 0 0 2008 10 29 1 0 1 2007 10 10 1
12. 15 14 32011 Compact BLCDN 4M12S 4Al VI 10 Parameters 10 1 DeviceNet Parameters Industr A Gateway parameters fieldbus communication The module provides the following parameters to configure the DeviceNet communication The parameters are described in module specific EDS files which allow text based parameterization in EDS interpreting configuration tools like RSNetworx from Rockwell Automation for example For a parameterization via Class Instance Attribute C A please find the necessary information in brackets hexadecimal format Parameter MAC ID 03 01 01 Baud rate 03 01 02 AutoBaud 03 01 64 on UO cntcn timeout 64 02 73 Description 0 to 63 0 125 kbps 1 250 kbps 2 500 kbps 0 disable 1 enable Defines the output behavior in case of I O connection timeout 0 switch outputs faulted 1 switch outputs off 2 hold outputs 0 holf CAN chip in BUS OFF state BUS OFF irtp 03 01 03 default setting 10 2 4Al VI Parameters Parameter 4Al VI ch 1 operation mode 76 01 A5 to 4Al VI ch 4 operation mode 76 01 A8 4Al VI ch 1 data representation 76 01 B5 to 4Al VI ch 4 operation mode 76 01 B8 4Al VI disable diagnostics 76 01 C5 default setting 1 reset CAN chip Description Parameter for setting the operation mode for the respective channel 0 deactivate channel 10 V 10
13. bit Sigma Delta 16 bit signed integer 12 bit full range left justified 40 70 C 40 85 C firm mounting on base plate or machine IPGIK Glass filled nylon nickel plated brass connec tors Hans Turck GmbH 8 Co KG e D 45472 M lheim an der Ruhr e Witzlebenstrafe 7 e Tel 0208 4952 0 e Fax 0208 4952 264 e more turck com e www turck com Edition 2011 3 15 Compact BLCDN 4M12S 4Al VI Industr A 5 Fieldbus and UO connections 5 1 Pinning and wiring diagram 8 32011 Fieldbus accessories Fieldbus DeviceNet fieldbus connection cable for ex ample RSC RKC572 2M Ident no 6603629 OWN HOON QO lt lt L T oe analog inputs Pin configuration 1 VSENS 2 Al 3 GND 4 Al 5 PE 2 wire technology Hans Turck GmbH 8 Co KG e D 45472 M lheim an der Ruhr e Witzlebenstrafe 7 e Tel 0208 4952 0 e Fax 0208 4952 264 e more turck com e www turck com G E CORD WON ll WON OO lt lt Z T Edition 2011 3 15 Compact BLCDN 4M12S 4Al VI 6 Commissioning All new settings become valid only after a 6 1 Address setting The DeviceNet address setting at the mod ule is done via the two decimal rotary cod ing switches under the protective cover De viceNet allows a maximum of 64 00 to 63 addresses MAC IDs to be assigned Each ad dress may be allocated only once in the entire bus structure 6 2 Setting the transmission rate The module provides automatic transmission
14. el 0208 4952 0 e Fax 0208 4952 264 e more turck com e www turck com Edition 2011 3 15 Compact BLCDN 4M12S 4Al VI 1 Industr A General safety notes 1 1 Before the installation 4 32011 Disconnect the power supply of the device Ensure that devices cannot be accidentally restarted Verify isolation from the supply Earth and short circuit Cover or enclose neighboring units that are live Follow the engineering instructions of the device concerned Only suitably qualified personnel in accordance with EN 50 110 1 2 VDE 0 105 Part 100 may work on this device system Before installation and before touching the device ensure that you are free of electrostatic charge The functional earth FE must be connected to the protective earth PE or to the potential equalisation The system installer is responsible for implementing this connection Connecting cables and signal lines should be installed so that inductive or capacitive interference do not impair the automation functions Install automation devices and related operating elements in such a way that they are well protected against unintentional operation Suitable safety hardware and software measures should be implemented for the I O interface so that a line or wire breakage on the signal side does not result in undefined states in the automation devices Ensure a reliable electrical isolation of the Ensure a reliable electrical isolation of the low low volta
15. ge for the 24 volt supply Only use power supply units complying with IEC 60 364 4 41 VDE O 100 Part 410 or HD 384 4 41 S2 Deviations of the mains voltage from the rated value must not exceed the tolerance limits given in the specifications otherwise this may cause malfunction and dangerous operation Emergency stop devices complying with IEC EN 60 204 1 must be effective in all operating modes of the automation devices Unlatching the emergency stop devices must not cause restart Devices that are designed for mounting in housings or control cabinets must only be operated and controlled after they have been installed with the housing closed Desktop or portable units must only be operated and controlled in enclosed housings Measures should be taken to ensure the proper restart of programs interrupted after a voltage dip or failure This should not cause danger ous operating states even for a short time If necessary emergency stop devices should be implemented Wherever faults in the automation system may cause damage to persons or property external measures must be implemented to ensure a safe operating state in the event of a fault or malfunction for example by means of separate limit switches mechanical interlocks etc The electrical installation must be carried out in accordance with the relevant regulations e g with regard to cable cross sections fuses PE All work relating to transport installation commissioning and main
16. operation in liquids 6 32011 Hans Turck GmbH amp Co KG e D 45472 M lheim an der Ruhr e WitzlebenstraRe 7 e Tel 0208 4952 0 e Fax 0208 4952 264 e more turck com e www turck com Edition 2011 3 15 Compact BLCDN 4M12S 4Al VI 4 Technical data Type Ident No BLCDN 4M12S 4Al VI 6811003 24 VDC Industr A Supply voltage Admissible range System power supply Nominal voltage V Nominal voltage Vo Max sensor supply lsens Max load current lo 11 30 VDC via DeviceNet cable 24 VDC 24 VDC 4A 4A Fieldbus transmission rate Adjustment transmission rate Fieldbus addressing range Fieldbus addressing Service interface Fieldbus connection technology Fieldbus termination 125 500 kbps auto detection 0 63 64 80 Programmable MACID 81 Vendor Specific 2 decimally coded rotary switches RS232 interface 2 x M12 5 pin external 99 Analog inputs Input type Type of input diagnostics Sensor supply Input resistance Maximum limiting frequency analog Basic fault limit at 23 C Repeatability Temperature coefficient Resolution Measuring principle Measured value display Operating temperature Storage temperature Extended vibartion resistance up to 20 g at 10 to 150 Hz Protection class housing material 7 32011 0 4 20 mA or 10 0 10 VDC channel diagnostics 24 VDC 0 125 or 98 5 KQ lt 20 Hz 0 3 Yo 0 05 Yo lt 300 ppm C of full scale 16
17. tenance must only be carried out by qualified personnel IEC 60 364 and HD 384 and national work safety regulations All shrouds and doors must be kept closed during operation Hans Turck GmbH amp Co KG e D 45472 M lheim an der Ruhr e WitzlebenstraRe 7 e Tel 0208 4952 0 e Fax 0208 4952 264 e more turck com e www turck com Edition 2011 3 15 Compact BLCDN 4M12S 4Al VI Industr A 2 General information This manual includes all information necessary for the prescribed product It has been specially conceived for personnel with the necessary qualifications A ATTENTION Please read this section carefully Safety aspects cannot be left to chance when dealing with electrical equipment 2 1 Description of symbols Used T WARNING This sign can be found next to all notes that indicate a source of hazards This can refer to danger to personnel or damage to the system hardware and software and to the facility This sign means for the operator work with extreme caution T ATTENTION This sign can be found next to all notes that indicate a potential hazard This can refer to possible danger to personnel and dam ages to the system hardware and software and to the facility NOTE This sign can be found next to all general notes that supply important information about one or more operating steps These spe cific notes are intended to make operation easier and avoid unnecessary work due to incorrect operation

Download Pdf Manuals

image

Related Search

Related Contents

karel dt04 dect base unit technical reference & user's  Check function  manual de operador 450aj  Sharp TMAN-A047WJZZ User's Manual  取扱説明書 TFIR-31 シリーズ 定置型 1 次元/2 次元イメージリーダ  i-Plant Evolution  2005年 (PDF 2.2MB)  Samsung AE050009 projector accessory    藝Zine - Honda Cars 東京西  

Copyright © All rights reserved.
Failed to retrieve file