Fiberlite F15-8x50c Rotor User Manual

image

Contents

1. u TREO 5 2 Checking the Aerosol Tightness 5 2 Chapter6 Maintenance and Care 2222 6 1 er M 6 2 asua 6 2 Disinfection u p T 6 2 Handling and Care of Rotors and Accessories made of Aluminum 6 3 Decontamination ANN 6 4 Thermo Scientific 75003663 F15 8x50c i Table of Contents 75003663 F15 8x50c OR TEREN 6 4 Service of Thermo Fisher Scientific 6 5 a a 1 Chemical Compatibility Chart B 1 Warranty and recommended Service Life C 1 E uve D 1 Thermo Scientific P Preface Before starting to use the rotor read through these Operating Instructions carefully and follow the instructions The information contained in these Operating Instructions is the property of Thermo Fisher Scientific it is forbidden to copy or pass on this information without explicit approval Failure to follow the instructions and safety information in this instruction manual will result in the expiration of the seller s warranty Scope of Supply Article Number Quantity Check 75003663 FIBERLite F15 8x50c 1 76003500 Rubber seal grease 1 700
2. IMPORTANT Please reference this page for the most up to date information on the following e Web site addresses e contact information copyright and trademark information subsequent pages in this manual may have incorrect web site addresses and contact information 2013 Thermo Fisher Scientific Inc All rights reserved HERAEUS is a registered trademark of Heraeus Holding GmbH licensed to Thermo Fisher Scientific Delrin TEFLON and Viton are registered trademarks of DuPont Noryl is a registered trademark of SABIC POLYCLEAR is a registered trademark of Hongye CO Ltd Hypaque is a registered trademark of Amersham Health As RULON A and Tygon are registered trademarks of Saint Gobain Performance Plastics Alconox is a registered trademark of Alconox Ficoll is a registered trademark of GE Healthcare Haemo Sol is a registered trademark of Haemo Sol Triton X 100 is a registered trademark of Sigma Aldrich Co LLC All other trademarks are the property of Thermo Fisher Scientific Inc and its subsidiaries Manufacturer Thermo Fisher Scientific Robert Bosch StraBe 1 D 63505 Langenselbold Germany Thermo Fisher Scientific Inc provides this document to its customers with a product purchase to use in the product operation This document is copyright protected and any reproduction of the whole or any part of this document is strictly prohibited except with the written authorization of Thermo Fisher Scientific Inc Th
3. Canada 1 866 984 3766 Austria 43 1 801 400 Belgium 132 2 482 30 30 Germany 08001 536 376 49 6184 90 6940 France 33 2 2803 2180 33 2 2803 2000 Italy 39 02 02 95059 341 Netherlands 31 76 571 4440 Nordic Baltic Countries 35 89 329 100 Russia 7 812 703 42 15 Thermo Scientific 75003663 F15 8x50c D 1 D Contact Information Spain Portugal Switzerland UK Ireland China 34 932 23 09 18 34 932 23 09 18 41 44 454 12 12 44 870 609 9203 86 21 6865 4588 India Japan Other Asian Countries Latin America Other Countries 86 10 8419 3588 91 22 6716 2200 81 45 453 9220 852 2885 4613 1 866 984 3766 49 6184 90 6940 D 2 75003663 F15 8x50c 33 2 2803 2180 Thermo Scientific Index A ACCESSORIES 2 1 Aerosol tight Applications 5 1 Aluminum 6 3 EN c 6 4 Basic Principles 5 2 Before Run 4 2 C 6 1 Checking the Aerosol Tightness 5 2 Cleaning Agents sesen 6 2 Contact Information 2 D 1 D Decontamination 6 4 Disinfection n 6 2 F Fill Devel 5 2 H Heraeus 1 2 Improper 4 3 Intervals enne 6 2 Maintenance 6 1 P PrecautiONHS uu
4. Decontaminate the affected parts immediately Take other precautions if need be 6 2 75003663 15 8 50 Thermo Scientific 6 Maintenance and Care Handling and Care of Rotors and Accessories made of Aluminum The rotor chamber and the rotor should be treated preferably with a neutral disinfectant A disinfectant spray would be most suitable for this purpose so that the rotor and accessory surfaces are covered evenly WARNUNG Observe the safety precautions and handling instructions for the cleaning agents used Contact the service department of Thermo Fisher Scientific for questions regarding the use of other disinfectants Disinfect the rotor and accessories as follows I QN N 10 Open the centrifuge Turn off the centrifuge Pull out the power supply plug Grasp the rotor with both hands and lift it vertically off the centrifuge spindle Remove the centrifuge tubes and adaptors and dispose of them or disinfect them Treat the rotor and rotor lid according to the instructions for the disinfectant spray or soak in solution Adhere strictly to the given application times Be sure the disinfectant can drain off the rotor Rinse the rotor and rotor lid thoroughly with water and then rub down Dispose of the disinfectant according to the applicable guidelines Treat aluminum rotors afterwards with an anti corrosion oil 7000 9824 Apply a thin layer of oil using a soft cloth Han
5. SS iii iii Thermo Scientific Proper Loading 4 2 0 Quick 5 2 Removing the Rotor 3 3 Rotor Installation nyjeve en n 3 2 Rotor Loading 4 Rotor Specifications oleo b cet end do ta 1 1 S Scope of Supply uu aaa E qasa iii r 6 5 Sorvall e 1 4 VV brace B C 1 75003663 F15 8x50c 1 1
6. 4 Rotor Loading Before Run Before Run 1 Please read and observe the safety instructions contained in these operating instructions and in the instructions for use 2 Check the rotor and all accessory parts for damages such as cracks scratches or traces of corrosion 3 Check the rotor chamber the centrifuge spindle and the AutoLock 4 Check the rotors suitability using the chemical compatibility chart on page 1 5 Make sure the tubes or bottles do not touch the lid Proper Loading To ensure safe operation of the centrifuge the rotor must be evenly loaded at all times 4 2 75003663 15 8 50 Thermo Scientific Improper Loading f E Thermo Scientific 75003663 F15 8x50c 4 3 4 Rotor Loading Maximum Loading Maximum Loading The rotor can run at high speeds The rotor design has sufficient reserve stability even when spinning at top speed The safety system of the centrifuge requires that you symetrically balance the tubes in the rotor This refers to each cavity There are two options available for centrifuging samples whose weight including adaptor exceeds the maximum permissible load Reduce the fill level Reduce the speed Use this formular zn M permissible load m NS Effective load n admissible speed adm n maximum speed max 4 4 75003663 F15 8x50c Thermo Scientific Aerosol tight Applications Thermo Scie
7. RULONA TEFLON Glutaraldehyde oj o ci ci Glycerol Guanidine Hydrochloride Haemo Sol Hexane vj vl cj Z zc ALUMINUM vj vj nj Z mij mj mj mj mj co ci vj CO Z vj vj nA cj nj Z STAINLESS STEEL 070 Isobutyl Alcohol Isopropyl Alcohol lodoacetic Acid Potassium Bromide Potassium Carbonate co Potassium Chloride Potassium Hydroxide 596 mi mij mj mj mj co mij mij mj mj mj co mj mj ml mj mj mj mj minj mj ni cl aj a NYLON vj vj ml zj co cj nj nj mj c coc SIICONERUBBER Potassium Hydroxide conc Potassium Permanganate ci aj lt Calcium Chloride C ni co lt vj lt co NM CO A mij MA mj mj mj mij mi co Calcium Hypochlorite Kerosene zj vj vj vj mj mj sz C cj nj nj mj ml mj co ci ci ci c NEOPRENE nj nj ci mi mi mi ml A mj ml ml ml co Sodium Chloride 1096 Sodium Chloride sat d co 1 zj nn Carbon Tetrachloride Mm G nj nj nj co lt Mm mj nj zio o al zj vj vj z z o C Z c c Aqua Regia gt lt C c 1 1 1 1
8. 1 Rotor Specification Heraeus Centrifuge Heraeus Multifuge X3 Heraeus Multifuge X3F Heraeus Multifuge X1 Catalog 75004501 75004531 75004211 Weight empty kg of rotor 4 44 4 44 4 44 Maximum permissible load g 8x75 8x75 8x75 maximum speed Nmax rpm 14500 14500 14000 maximum RCF value at nmax 24446 24446 22789 max min radius cm 43 10 4 43 104 43 104 Pitch angle 25 25 25 Accel braking time s 95 65 95 65 100 80 sample heating at nmax C referred to ambient 21 21 21 temperature of 23 C running time 60 minutes aerosol tight no no no max temperature for autoclaving 121 121 121 Table 1 4 120V 60Hz refrigerated Centrifuge Heraeus Multifuge X3R Heraeus Multifuge X3FR Heraeus Multifuge XIR Catalog 75004516 75004537 75004251 Weight empty kg of rotor 4 44 4 44 4 44 Maximum permissible load 9 8x75 8x75 8x75 maximum speed nmax rpm 14500 14500 14000 maximum RCF value at nmax 24446 24446 22789 max min radius cm 43 10 4 43 10 4 43 104 Pitch angle 25 25 25 Accel braking time s 85 85 85 85 100 80 aerosol tight no no no max temperature for autoclaving 121 121 121 Thermo Scientific 75003663 15 8 50 1 3 1 Rotor Specification Sorvall Sorvall Table 1 5 230V 50Hz 60Hz ventilated Centrifuge Sorvall Legend XT Sorvall Legend XF Sorvall Legend X1 Catalog 75004
9. lt lt lt lt lt lt o ci ci c DERN c Z Z Z Trichloroethane c c c ni vj nj zj ni cj nj nj aj ccc c POLYVINYL CHLORIDE cj cj cj c cj vj c C Z cj cj cl vl ml ml ml ml C co BUNAN vj cj vl vl vl c c c c c c cl cl cl ml cuc co NYLON c c zj cl cj co cj cl vj cl cj el nj C POLYCARBONATE C cl c zi ZI Pj ni mj mi mj mi C SILICONE RUBBER Cl Cl 0 wn gt Trichloroethylene Trisodium Phosphate Tris Buffer neutral pH co Triton X 1009 Urea ci Hydrogen Peroxide 10 Hydrogen Peroxide 396 Xylene mi cj mj mj mi ml ml c cj nj nj c mi zi POLYALOMER oj zi vj vj nj nj ni cl cj ni zj cl oj zi vj nj nj cl zj nj nj a ni a C ti POLYRTHYLENE mj cj mj ml mi mi ml c cj nj cj cj nj cc mi ci POLYPROPYLENE ni ni ni Al Al Al Al aA Al wD wD alal tj tj RULONA TEFLON MN vj ml mj mj mj nj cj cl aj cj cl cl zj vj nj nj nj nj aj Co TITANIUM gt oj z lt o ni nln nA o o a wm c z an a
10. max min radius cm 43 10 4 43 104 43 104 Pitch angle 25 25 25 Accel braking time s 95 65 95 65 100 80 sample heating at nmax C referred to ambient 21 21 21 temperature of 23 C running time 60 minutes aerosol tight no no no max temperature for autoclaving 121 121 121 Table 1 8 120V 60Hz refrigerated Centrifuge Sorvall Legend XTR Sorvall Legend XFR Sorvall Legend X1R Catalog 75004521 75004539 75004261 Weight empty kg of rotor 4 44 4 44 4 44 Maximum permissible load g 8x75 8x75 8 75 maximum speed nmax rpm 14500 14500 14000 maximum RCF value at nmax 24446 24446 22789 max min radius cm 43 10 4 43 10 4 43 104 Pitch angle 25 25 25 Accel braking time s 85 65 85 65 100 80 aerosol tight no no no max temperature for autoclaving 121 121 121 Thermo Scientific 75003663 15 8 50 1 5 1 Rotor Specification Sorvall Table 1 9 100V 50Hz 60Hz ventilated Centrifuge Sorvall Legend XT Sorvall Legend XF Sorvall Legend X1 Catalog 75004507 75004534 75004223 Weight empty kg of rotor 4 44 4 44 4 44 Maximum permissible load g 8 75 8 75 8x75 maximum speed nmax rpm 14500 14500 13500 maximum RCF value at nmax 24446 24446 21181 max min radius 43 10 4 43 10 4 43 10 4 Pitch angle 25 25 25 Accel braking time s 110 65 110 65 110 75 sample heating at Nmax C referred to 21 21 ambient te
11. 09824 Anti corrosion oil 1 L 50120015 Instruction Manual 1 If any parts missing please contact the nearest Thermo Fisher Scientific representative Precautions In order to ensure safe operation of the FIBERLite 7 F15 8x50c the following general safety regulations must be followed Do not remove the magnet at the rotor bottom Do not use rotors which show any signs of corrosion and or cracks Useonly with rotors that have been loaded properly Never overload the rotor Thermo Scientific 75003663 F15 8x50c iii Preface Use only accessories which have been approved by Thermo Fisher Scientific Exceptions to this rule are commercially available glass or plastic centrifuge tubes provided they have been approved for the speed or the RCF value of the rotor Please observe the safety instructions Please pay particular attention to the following aspects Rotor installation Check that the rotor is locked properly into place before operating the centrifuge Always balance the samples Maximum sample density at maximum speed 124 m This symbol refers to general hazards ATTENTION means that material damage could occur WARNING means that injuries or material damage or contamination could occur This symbol refers to biological hazards Observe the information contained in the instruction manual to keep yourself and your environment safe iv 75003663 15 8 50 Thermo Scientific Rotor
12. 3 10 4 9155 22143 13900 4 3 10 4 9288 22465 14000 4 3 10 4 9423 22789 14100 4 3 10 4 9558 23116 4 75003663 15 8 50 Thermo Scientific Thermo Scientific Speed rpm Rin Rinax RCF Rmin RCF Rmax 14200 4 3 10 4 9694 23445 14300 4 3 10 4 9831 23776 14400 4 3 10 4 9969 24110 14500 4 3 10 4 10108 24446 A RCF Values 75003663 F15 8x50c A 5 RCF Values A 6 75003663 F15 8x50c Thermo Scientific Chemical Compatibility Chart lt POLYCLEAR CLEARCRIMP CCCLEARCRIMP 2 z2 REE y 5 u 8 m CHEMICAL PEST SEES EGER EEZSEEEEZ 155 2 mercaptoethanol 5 S U SMS 5 0 5 5 5 5 5 5 5 5 US 5 5 5 5 5 Acetaldehyde 5 U U MU U U M M MS U 5 U Acetone MS U U U M S UU 5 U 5 U UU 5 5 UU 5 MMS U U Acetonitrile SSU SMS 5 5 US U MU 5 MU 5 5 5 5 U U Alconox UU 5 5 5 5 SSSSSSMSSSSSSSSSSS Allyl Alcohol U 5 5 5 5 MS 5 5 MS 5 Aluminum Chloride UU 5 5 5 5 5 5 5 SMS 5 5 5 5 5 5 5 5 5 5 Formic Acid 10096 S MU U U SMUUSS U 5 U 5 U Ammonium Acetate S S U 5 5 5 5 5 5 5 5 9 5 5 5 5 5 5 5 5 5 5 5 Ammonium Carbonate MSU 5 5 5 5 5 5 5 65656565 5 5 5 5 5 SMS 5 5 Ammonium Hydroxide 1096 U US 5 5 5 5 5 5 5 SUMS 5 5 5 5 5 5 5 5 Ammonium Hydroxide 2896 UUSUSUMSSSSSUSUMSSSSSSSSSMS Ammonium Hydroxide conc UU U US 5 UMS S S US U U 5 5 5 5 5 5 5 U Ammonium Phos
13. 4 3 10 4 658 1592 3800 4 3 10 4 694 1679 3900 4 3 10 4 731 1768 4000 4 3 10 4 769 1860 4100 4 3 10 4 808 1955 4200 4 3 10 4 848 2051 4300 4 3 10 4 889 2150 4400 4 3 10 4 931 2251 4500 4 3 10 4 973 2355 4600 4 3 10 4 1017 2460 4700 4 3 10 4 1062 2568 4800 4 3 10 4 1108 2679 4900 4 3 10 4 1154 2792 5000 4 3 10 4 1202 2907 5100 4 3 10 4 1250 3024 5200 4 3 10 4 1300 3144 5300 4 3 10 4 1350 3266 5400 4 3 10 4 1402 3390 5500 4 3 10 4 1454 3517 5600 4 3 10 4 1508 3646 5700 4 3 10 4 1562 3778 5800 4 3 10 4 1617 3911 5900 4 3 10 4 1673 4047 6000 4 3 10 4 1731 4186 6100 4 3 10 4 1789 4326 6200 4 3 10 4 1848 4469 6300 4 3 10 4 1908 4615 6400 4 3 10 4 1969 4763 6500 4 3 10 4 2031 4912 6600 4 3 10 4 2094 5065 6700 4 3 10 4 2158 5219 75003663 15 8 50 Thermo Scientific RCF Values Speed rpm Bax RCF Rmin RCF Rmax 6800 4 3 10 4 2223 5376 6900 4 3 10 4 2289 5536 7000 4 3 10 4 2356 5697 7100 4 3 10 4 2423 5861 7200 4 3 10 4 2492 6028 7300 4 3 10 4 2562 6196 7400 4 3 10 4 2633 6367 7500 4 3 10 4 2704 6540 7600 4 3 10 4 2111 6716 7700 4 3 10 4 2850 6894 7800 4 3 10 4 2925 7074 7900 4 3 10 4 3000 7257 8000 4 3 10 4 3077 7441 8100 4 3 10 4 3154 7629 8200 4 3 10 4 3232 7818 8300 4 3 10 4 3312 8010 8400 4 3 10 4 3392 8204 8500 4 3 10 4 3473 8401 8600 4 3 10 4 3556 8599 8700 4 3 10 4 3639 8801 8800 4 3 10 4 3723 9004 8900 4 3 10 4 3808
14. 505 75004532 75004220 Weight empty kg of rotor 4 44 4 44 4 44 Maximum permissible load g 8 75 8x75 8x75 maximum speed rpm 14500 14500 14500 maximum value at nmax 24446 24446 24446 max min radius cm 43 10 4 43 10 4 43 10 4 Pitch angle 25 25 25 Accel braking time s 75 65 75 65 80 80 sample heating at C referred to 21 21 21 ambient temperature of 23 running time 60 minutes aerosol tight no no no max temperature for autoclaving 121 121 121 Table 1 6 230V 50Hz 60Hz refrigerated Centrifuge Sorvall Legend XTR Sorvall Legend XFR Sorvall Legend X1R Catalog 75004520 75004538 75004260 Weight empty kg of rotor 4 44 4 44 4 44 Maximum permissible load g 8x75 8x75 8x75 maximum speed nmax rpm 14500 14500 14500 maximum RCF value at nmax 24446 24446 24446 max min radius cm 43 104 43 10 4 43 10 4 Pitch angle 25 25 25 Accel braking time s 75 65 75 65 80 80 aerosol tight no no no max temperature for autoclaving 121 121 121 14 75003663 F15 8x50c Thermo Scientific 1 Rotor Specification Sorvall Table 1 7 120V 60Hz ventilated Centrifuge Sorvall Legend XT Sorvall Legend XF Sorvall Legend X1 Catalog 75004506 75004533 75004221 Weight empty kg of rotor 4 44 4 44 4 44 Maximum permissible load g 8x75 8x75 8x75 maximum speed Nmax rpm 14500 14500 14000 maximum RCF value at nmax 24446 24446 22789
15. 90 6000 358 9 329 10200 Countries not listed 49 6184 90 6000 Part of Thermo Fisher Scientific Thermo Fisher Scientific FIBERLite F15 8x50c Instruction Manual 50120015 1 June 2009 Jm Table of Contents Prelat mmt RENE iii SCONE ol Supply ione cioe leid tuba ode td an edenda cda eaea a needed ili i ili Glhapter t Rotor Specification u U u 1 1 Heraeus EE 1 2 230V 50FHz 60Fzventilated uuu i na 1 2 230V 50Hz 60Hz refrigerated Las er hrs ries ss 1 2 eadera rii T ndie 1 3 120V 60Hz refrigerated oou nad t 1 3 Sorvall TOT 1 4 230V 50Hz 60Hz ventilated s 1 4 230V 50Hz 60Hz refrigerated asniher 1 4 120V 60Hz ventilated 1 5 120 V 6011zrefriserated ser rap di iii 1 5 100V 50Hz 60HFIz uiri Me 1 6 e irete i iait 1 6 Chapter 2 Accessories 2 1 Chapter3 Autokock vune cc soocere aa reres eee erret rere 3 1 Rotor Installati n H 3 2 Removing thi Rot r aus ot n R 3 3 Chapter4 Rotor ea 4 1 Before Med PE T 4 2 4 2 Improper Loading genit indin 4 3 Meni Lon N RT PT 4 4 Chapter 5 Aerosol tight Applications 22 22 5 1 Basie Principles nera r d i ang e 5 2
16. 9210 9000 4 3 10 4 3894 9418 9100 4 3 10 4 3981 9628 9200 4 3 10 4 4069 9841 9300 4 3 10 4 4158 10056 9400 4 3 10 4 4248 10274 9500 4 3 10 4 4339 10494 9600 4 3 10 4 4430 10716 9700 4 3 10 4 4523 10940 9800 4 3 10 4 4617 11167 9900 4 3 10 4 4712 11396 10000 4 3 10 4 4807 11627 10100 4 3 10 4 4904 11861 10200 4 3 10 4 5002 12097 10300 4 3 10 4 5100 12335 10400 4 3 10 4 5200 12576 Thermo Scientific 75003663 F15 8x50c A 3 RCF Values Speed rpm Rin Re RCF RCF 10500 4 3 0 4 5300 12819 10600 4 3 0 4 5402 13064 10700 4 3 10 4 5504 13312 10800 4 3 10 4 5607 13562 10900 4 3 10 4 5712 13814 11000 4 3 10 4 5817 14069 11100 4 3 10 4 5923 14326 11200 4 3 10 4 6030 14585 11300 4 3 10 4 6139 14847 11400 4 3 10 4 6248 15111 11500 4 3 10 4 6358 15377 11600 4 3 10 4 6469 15646 11700 4 3 10 4 6581 15916 11800 4 3 10 4 6694 16190 11900 4 3 10 4 6808 16465 12000 4 3 10 4 6923 16743 12100 4 3 10 4 7039 17023 12200 4 3 10 4 7155 17306 12300 4 3 10 4 7273 17591 12400 4 3 10 4 7392 17878 12500 4 3 10 4 7512 18168 12600 4 3 10 4 7632 18459 12700 4 3 10 4 7754 18754 12800 4 3 10 4 7876 19050 12900 4 3 10 4 8000 19349 13000 4 3 10 4 8125 19650 13100 4 3 10 4 8250 19953 13200 4 3 10 4 8376 20259 13300 4 3 10 4 8504 20567 13400 4 3 10 4 8632 20878 13500 4 3 10 4 8761 21191 13600 4 3 10 4 8892 21506 13700 4 3 10 4 9023 21823 13800 4
17. Solution 555 2096 Magnesium Chloride Mercaptoacetic Acid Thermo Scientific z ci vj vj cj zj vj nm ml cj zj ni lt zj nj nj zj c cl ci mi BUNAN 1 1 1 1 1 1 1 1 1 1 1 1 C co vj vj cj zj vj zj vj nA nj lt co nj mj mj c mj zj mi Z mij ti POLYALOMER ci vj nm cj cj vj cj nj cj nj nj cj cj nj c cl zi mi POLYCARBONATE ci vj nm cj zj vj coz zj c mj mj CO c mi CO mi a ml ci cO POLYPROPYLENE 75003663 F15 8x50c mj ni ci zj nm vj c zj nj nj zj nj nm CO aj TITANIUM Chemical Compatibility Chart 2 E E 8 2 d t v gt Methyl Alcohol 5 5 5 US 5 5 5 5 5 5 US UMS 5 5 5 5 5 5 MS MU Methylene Chloride U U UU 5 5 US UU 5 UU U UU MU UU 5 5 MUS U Methyl Ethyl Ketone S 5 VU 5 5 MS 5 UU 5 US U 00550 0555550 0 Metrizamide MSS 555 5 5 5 5 5 5 SS 5 5 5 5 MS 5 5 Lactic Acid 100 5 MS U 5 5 5 MS 5 MS MS 5 5 Lactic Acid 2096 5 5 MS 5 5 5 5 5 9 5 MS 5 5 5 N Butyl Alcohol S 5 S 5 US MS 5 5 5 MMS M 5 5 N Butyl Phthalate 55 5 5 5 SUUSUUUM UUSUSMMSUS N N Dimethylformamide 5 5 5 5 MS 5 5 US US UU 5 SUUS MS 5 5 U So
18. Specification Contents Heraeus on page 1 2 e Sorvall on page 1 4 Thermo Scientific 75003663 F15 8x50c 1 1 1 Rotor Specification Heraeus Heraeus Table 1 1 230V 50Hz 60Hz ventilated Centrifuge Heraeus Multifuge X3 Heraeus Multifuge X3F Heraeus Multifuge X1 Catalog 75004500 75004530 75004210 Weight empty kg of rotor 4 44 4 44 4 44 Maximum permissible load g 8 75 8x75 8x75 maximum speed rpm 14500 14500 14500 maximum value at nmax 24446 24446 24446 max min radius cm 43 10 4 43 10 4 43 10 4 Pitch angle 25 25 25 Accel braking time s 75 65 75 65 80 80 sample heating at C referred to 21 21 21 ambient temperature of 23 running time 60 minutes aerosol tight no no no max temperature for autoclaving 121 121 121 Table 1 2 230V 50Hz 60Hz refrigerated Centrifuge Heraeus Multifuge X3R Heraeus Multifuge X3FR Heraeus Multifuge XIR Catalog 75004515 75004536 75004250 Weight empty kg of rotor 4 44 4 44 4 44 Maximum permissible load 9 8x75 8x75 8x75 maximum speed nmax rpm 14500 14500 14500 maximum RCF value at nmax 24446 24446 24446 max min radius cm 4 3 10 4 43 10 4 43 10 4 Pitch angle 25 25 25 Accel braking time s 75 65 75 65 80 80 aerosol tight no no no max temperature for autoclaving 121 121 121 12 75003663 F15 8x50c Thermo Scientific Table 1 3 120V 60Hz ventilated
19. al ions also trace amounts Anhydrous chlorinated solvents Salt water Clean the aluminum parts thoroughly whenever they come into contact with these substances Decontamination For general radioactive decontamination use a solution of equal parts of 7096 ethanol 1096 SDS and water Rinse the rotor first with ethanol and then with de ionized water Dry off the rotor with a soft cloth Dispose of all rinsing solutions in a container suitable for radioactive waste Autoclaving Autoclaving is permitted Rotors and adapters can be autoclaved at 121 The permissible autoclave cycle is 20 min Clean the rotor before autoclaving and rinse it with distilled water Remove all accessories tubes adaptors from the rotor No chemical additives are permitted in the steam CAUTION Never exceed the permitted temperature and duration when autoclaving If the rotor shows signs of corrosion or wear it must be replaced 6 4 75003663 F15 8x50c Thermo Scientific 6 Maintenance and Care Service of Thermo Fisher Scientific Service of Thermo Fisher Scientific Thermo Fisher Scientific recommends having the centrifuge and accessories serviced once a year by an authorized service technician The service technicians check the following the electrical equipment the suitability of the set up site the lid lock and the safety system the rotor the mated parts of the rotor and the drive shaft Defective material is rep
20. cj ci cj ci C ci zm zi zj zi ni AUMINUM CELLULOSE ACETATE BUTYRATE Physiologic Media Serum Urine Picric Acid co POLYTHERMIDE POLYESTER GLASS THERMOSET Pyridine 5096 Rubidium Bromide Rubidium Chloride Sucrose naj co ml zi co POLYSULFONE Sucrose Alkaline co mi mj mj mj a ci Co PET POLYCLEAR CLEARCRIMPOCCCLEARCRIMPO Sulfosalicylic Acid Nitric Acid 1096 mij ml cj mj mi mj ni ANODIC COATING for ALUMINUM mj mj mil mij mj mil mi ci GLASS nj nj nj nj ni C mi nj MA mj mij mj mij mi co Nitric Acid 5096 Nitric Acid 9596 Hydrochloric Acid 1096 Hydrochloric Acid 5096 Sulfuric Acid 1096 cj mj mj mj mi mil mil Z NEOPRENE eco CA ci tal toj co oj t mj n mj al mi nj nj oc nj C Z c C ci VTN Sulfuric Acid 50 lt c C vj c ccc C Sulfuric Acid Stearic Acid cl Tetrahydrofuran Toluene cl vj ml Z cl cl cl C C vj vj vj c z Z Z 5 55 STEEL oj cj cj zi nja cj mj mj a a a a ci mj mj zeje t Trichloroacetic Acid aj zj lt
21. d Accessories Required Tube Vol Max Dims xL Cat No Vol Fill Description Qty Speed mm eus Qty Qty of at No 2896 Places 334959 50 50 Nunc Conical 25 14 500 30x115 Included 25 Sealing 366036 15 15 Nunc Conical 50 17x120 Included 50 PP Sealing 75100378 2 1 2 2 75003663 15 8 50 Thermo Scientific AutoLock Contents Rotor Installation on page 3 2 Removing the Rotor on page 3 3 Thermo Scientific 75003663 F15 8x50c 3 1 3 AutoLock Rotor Installation Rotor Installation CAUTION Unapproved or incorrectly combined accessories can cause serious damage to the centrifuge This rotor is equipped with an AutoLock system This system is used to automatically lock the rotor to the centrifuge spindle The rotor does not have to be bolted onto the centrifuge spindle Proceed as follows 1 Open the lid of the centrifuge and if necessary remove any dust foreign objects or residue from the chamber and o ring must be clean and undamaged AutoLock O ring Figure 1 AutoLock 2 Hold the rotor over the centrifuge spindle and let it slide slowly down the centrifuge spindle The rotor clicks automatically into place CAUTION Do not force the rotor onto the centrifuge spindle If the rotor is very light then it may be necessary to press it onto the centrifuge spindle with a s
22. dium Borate MS 5 5 5 5 5 5 5 5 5 0 5 5 5 5 5 5 5 5 5 5 5 5 5 Sodium Bromide USS SSS 5 5 5 5 5 5 5 5 5 95 5 5 5 53 5 5 5 Sodium Carbonate 2 MUS 5 5 5 5 5 5 5 5 5 5 SUS 5 5 5 5 5 5 5 5 SSS Sodium Dodecyl Sulfate 5 5 S 35 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 9 5 Sodium Hypochlorite 596 U U MS 5 MUS SMS 5 SMS 5 5 5 5 5 5 MUS MS Sodium lodide MS 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 MS 5 5 Sodium Nitrate SSS 5 5 5 5 5 5 5 5 5 9 5 5 5 5595 5 5 5 5 Sodium Sulfate USS 5 5 5 5 5 5 35 5 5 5 5 5 853585 5 5 5 5 5 5 5 Sodium Sulfide S 55 5 5 5 5 UU 5 5 5 S Sodium Sulfite 5 5 5 5 5 5 5 MS 5 5 5 5 SM 5 5 5 5 5 5 5 5 5 5 Nickel Salts US 5 5 5 5 5 5 5 5 5 5 S 5 5 5 5 5 5 MS 5 5 Oils Petroleum S 5 5 SUSSSSUUMSMUUSSSUSSSS Oils Other 5 SMS 5 5 5 US 5 5 5 US 5 5 5 5 5 MS Oleic Acid S USSSUUSUSSMSSSSSSSSSMUSMM Oxalic Acid 5 5 5 5 5 5 5 5 5 4 5 5 5 5 5 5 5 5 5 5 Perchloric Acid 10 U U SU U SMM MU MS MS U S S Perchloric Acid 7099 U U U U U 5 U MU U MU U U MMU U U S 5 Phenol 5 USU SMM SUMUUSUMSMSUUSUMMMS S Phenol 50 USU SUM SUMUUUUUSUMUUSUUUMS Phosphoric Acid 10 U U MS 5 5 5 5 5 5 SSSSSSSSSUMUSS Phosphoric Acid conc U U MM U MS UU MMS 5 5 MS MS U MU S B 4 75003663 F15 8x50c Thermo Scientific B Chemical Compatibility Chart CHEMICAL POLYURETHANE ROTOR PAINT COMPOSITE Carbon Fiber Epoxy ETHYLENE PROPYLENE MATERIAL cj vj vl ni Z Z
23. dling and Care of Rotors and Accessories made of Aluminum Thermo Scientific The aluminum parts are anodised and protected against corrosion to a large extent Avoid damaging the surface of aluminum parts in order to lengthen their lifetime Clean aluminum parts as follows Use warm water with a neutral solvent Never use caustic cleaning agents such as soap suds phosphoric acid bleaching solutions or scrubbing powder Rinse the cavities out thoroughly Use a soft brush without metal bristles to remove stubborn residue Afterwards rinse with distilled water and dry the parts off with a soft cloth Place the rotors on a plastic grate with their cavities pointing down If drying boxes are used the temperature must never exceed 50 C since higher temperatures could damage the material and shorten the lifetime of the parts 75003663 15 8 50 6 3 6 Maintenance and Care Decontamination The following substances will attack the aluminum parts Use only disinfectants with a pH of 6 8 After cleaning treat the entire surface of aluminum parts with corrosion protection oil 7000 9824 Also treat the cavities with oil Store the aluminum parts at room temperature or in a cold storage room with the cavities pointing down Bases in concentrated and diluted form Alkaline amines Alkaline soap solutions Strong acids Tannic acid oxalic acid trichloraceticacid Solutions with mercury copper and other heavy met
24. e contents of this document are subject to change without notice All technical information in this document is for reference purposes only System configurations and specifications in this document supersede all previous information received by the purchaser Thermo Fisher Scientific Inc makes no representations that this document is complete accurate or error free and assumes no responsibility and will not be liable for any errors omissions damage or loss that might result from any use of this document even if the information in the document is followed properly This document is not part of any sales contract between Thermo Fisher Scientific Inc and a purchaser This document shall in no way govern or modify any Terms and Conditions of Sale which Terms and Conditions of Sale shall govern all conflicting information between the two documents thermoscientific com Australia 61 39757 4300 India toll free 1800 22 8374 Russia 7 812 703 42 15 Austria 43 1 801 400 India 91 22 6716 2200 Spain Portugal 34 03 223 09 18 Belgium 32 53 73 42 41 Italy 32 02 95059 552 Switzerland 41 44 454 12 22 China 800 810 5118 or Japan 81 3 5826 1616 UK Ireland 44 870 609 9203 er m 400 650 5118 Netherlands 31 76 579 55 55 USA Canada 1 866 984 3766 France 33 2 2803 2180 New Zealand 64 9 980 6700 SCIENTIFIC Germany national toll free 0800 1 536 376 Nordic Baltic CIS countries Other Asian countries 852 2885 4613 Germany international 49 6184
25. hich they were not designed v causes external to the Goods such as but not limited to power failure or electrical power surges or vi use of the Goods in combination with equipment or software not supplied by Thermo Fisher Scientific If Thermo Fisher Scientific determines that Goods for which the Customer has requested warranty services are not covered by the warranty hereunder the Customer shall pay or reim burse Thermo Fisher Scientific for all costs of investigating and responding to such request at Thermo Fisher Scientific s then prevailing time and material rates If Thermo Fisher Scientific provides repair services or replacement parts that are not covered by the warranty provided in this Clause the Cus tomer shall pay Thermo Fisher Scientific therefor at Thermo Fisher Scientific s then prevailing time and materials rates Any installation maintenance repair service relocation or alteration to or of or other tampering with the Goods performed by any person or entity other than Thermo Fisher Scien tific without Thermo Fisher Scientific s prior written approval or any use of replacement parts not sup plied by Thermo Fisher Scientific shall immediately void and cancel all warranties with respect to the affected Goods Thermo Scientific 75003663 F15 8x50c C 1 C Warranty and recommended Service Life 2 75003663 F15 8x50c Thermo Scientific Contact Information United States 866 9 THERMO 1 866 984 3766
26. j nj mj c cl zj nj nj ni CO NYLON vj cj vj ni lt C z vj lt cj nj nj cj C co an zj cC ni mi mi mi ti ti c POLYALOMER co mj cj mj mi mi mi mj ml zj nj ni lt cj nj nj wm zj C cC c a mi ci c POLRTHYLNE mj cj mj ml mi zj ni co Z vj z nj nj nj c c a Z cC co al dl a ni ci C POLYPROPYLENE mij mil mij mi mi mil ml ml ml mj ml z zj C C ni mi ci ci co TITANIUM vi c cj c c zj nj C nj ni nl ni nj ni mj nj mj mi nin VITON oj WwW vj ci mj mja Mm DA nj nj nj nj N co Ethylene Glycol B 2 75003663 F15 8x50c Thermo Scientific CHEMICAL Ethylene Oxide Vapor MATERIAL ANODIC COATING for ALUMINUM CELLULOSE ACETATE BUTYRATE POLYURETHANE ROTOR PAINT DELRIN ETHYLENE PROPYLENE NORYL B Chemical Compatibility Chart POLYCLEAR CLEARCRIMP CCCLEARCRIMP POLYESTER GLASS THERMOSET POLYTHERMIDE Ficoll Hypaque co a COMPOSITE Carbon Fiber Epoxy cj GLASS a co TYGON a lt Hydrofluoric Acid 10 Hydrofluoric Acid 5096 cj N a POLYRTHYLENE a co POLYSULFONE Hydrochloric Acid Formaldehyde 4096 QI gt a ci POLYVINYL CHLORIDE cn a a a ci
27. l Clean rotor Daily or after every use Accessories Daily or after every use CAUTION Before using any other cleaning or decontamination process other than that recommended by Thermo Fisher Scientific is applied the user should check with Thermo Fisher Scientific that the planned process does not damage the device Use only approved cleansers If in doubt contact Thermo Fisher Scientific Cleaning 1 Open the centrifuge Turn off the centrifuge Pull out the power supply plug A oO N Grasp the rotor with both hands and lift it vertically off the centrifuge spindle Remove the centrifuge tubes and adaptors 6 Use a neutral cleaning agent with a pH value between 6 and 8 for cleaning 7 Dry all of the aluminum parts after cleaning with a cloth or in a warm air cabinet at a maximum temperature of 50 C CAUTION When cleaning do not allow liquids especially organic solvents to get on the drive shaft or the bearings inside the centrifuge Organic solvents break down the grease in the motor bearing The drive shaft could freeze up Disinfection Disinfect the rotor immediately whenever infectious material has spilled during centrifuging WARNUNG Infectious material can get into the centrifuge when a tube breaks or as a result of spills Keep in mind the risk of infection when touching articles and take all necessary precautions In case of contamination make sure that others are not put at risk
28. laced Thermo Fisher Scientific offers inspection and service contracts for this work This presupposes however that all prior service to the centrifuge has exclusively been done by a Thermo Fisher Scientific authorized service technician Thermo Scientific 75003663 F15 8x50c 6 5 B Maintenance and Care Service of Thermo Fisher Scientific 6 6 75003663 15 8 50 Thermo Scientific RCF Values Speed rpm Rin RCF Rmin RCF 300 4 3 10 4 4 10 400 4 3 10 4 8 19 500 4 3 10 4 12 29 600 4 3 10 4 17 42 700 4 3 10 4 24 57 800 4 3 10 4 31 74 900 4 3 10 4 39 94 1000 4 3 10 4 48 116 1100 4 3 10 4 58 141 1200 4 3 10 4 69 167 1300 4 3 10 4 81 196 1400 4 3 10 4 94 228 1500 4 3 10 4 108 262 1600 4 3 10 4 123 298 1700 4 3 10 4 139 336 1800 4 3 10 4 156 377 1900 4 3 10 4 174 420 2000 4 3 10 4 192 465 2100 4 3 10 4 212 513 2200 4 3 10 4 233 563 2300 4 3 10 4 254 615 2400 4 3 10 4 211 670 2500 4 3 10 4 300 721 2600 4 3 10 4 325 786 2700 4 3 10 4 350 848 2800 4 3 10 4 377 912 2900 4 3 10 4 404 978 3000 4 3 10 4 433 1046 Thermo Scientific 75003663 F15 8x50c 1 RCF Values A 2 Speed rpm Rin RCF 3100 4 3 0 4 462 1117 3200 4 3 0 4 492 1191 3300 4 3 10 4 524 1266 3400 4 3 10 4 556 1344 3500 4 3 10 4 589 1424 3600 4 3 10 4 623 1507 3700
29. le i i mi mj ni mn cj nj cj nj rn cj nl nl ec aml o nl ajl wm o nl o c o Z nm Zinc Chloride Thermo Scientific 75003663 F15 8x50c B 5 B Chemical Compatibility Chart Zinc Sulfate USS 5 5 5 5 5 5 5 5 5 5 5 3 5 5 8 5 5 5 5 5 3 5 5 Citric Acid 109 MS 5 5 SMS 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Polyethylencterephthalate l C S Satisfactory M attack may be satisfactory for use in centrifuge depending on length of exposure speed involved etc suggest testing under actual conditions of use U Unsatisfactory not recommended Performance unknown suggest testing using sample to avoid loss of valuable material Chemical resistance data is included only as a guide to product use Because no organized chemical resistance data exists for materials under the stress of centrifugation when in doubt we recommend pretesting sample lots B 6 75003663 F15 8x50c Thermo Scientific Warranty and recommended Service Life Recommended Rotoutype Warranty Years Retirement After Years FIBERLite F15 8x50c 15 Recommended Retirement Rotor Type Warranty After Years O ringe tubes bottles 30 Days 1 Thermo Fisher Scientific warrants that the Products will operate substantially in conformity with Thermo Fisher Scientific s
30. mall amount of pressure 3 Check if the rotor is properly installed by lifting slightly on the handle If the rotor can be pulled up then it must be reclamped to the centrifuge spindle WARNUNG If the rotor cannot be properly locked in place after several attempts then the is defective and you not permitted to operate the rotor Check for any damage to the rotor damaged rotors must not be used Keep the hub area clear of objects 3 2 75003663 F15 8x50c Thermo Scientific 3 AutoLockiM Removing the Rotor CAUTION Check that the rotor is properly locked on the centrifuge spindle before each use by pulling it a its handle Be sure to check all seals before starting any aerosol tight applications 4 Close the centrifuge door Removing the Rotor To remove the rotor proceed as follows 1 Open the centrifuge door 2 Grab the rotor handle with both hands and press against the green AutoLock button At the same time pull the rotor directly upwards with both hands and remove it from the centrifuge spindle Make sure not to jam the rotor while doing this Thermo Scientific 75003663 F15 8x50c 3 3 AutoLock Removing the Rotor 3 4 75003663 15 8 50 Thermo Scientific 4 Rotor Loading Rotor Loading Contents Before Run on page 4 2 Proper Loading on page 4 2 Improper Loading on page 4 3 Maximum Loading on page 4 4 Thermo Scientific 75003663 15 8 50 4 1
31. mperature of 23 running time 60 minutes aerosol tight no no no max temperature for autoclaving 121 121 121 Table 1 10 100V 50Hz 60Hz refrigerated Centrifuge Sorvall Legend XTR Sorvall Legend XFR Sorvall Legend X1R Catalog 75004522 75004540 75004263 Weight empty kg of rotor 4 44 4 44 4 44 Maximum permissible load g 8x75 8x75 8x75 maximum speed nmax rpm 14500 14500 14500 maximum RCF value at nmax 24446 24446 24446 max min radius cm 43 104 43 10 4 43 10 4 Pitch angle 25 25 25 Accel braking time s 85 65 85 65 100 80 aerosol tight no no no max temperature for autoclaving 121 121 121 1 6 75003663 F15 8x50c Thermo Scientific Accessories Contents data on page 2 2 e Accessories on page 2 2 Thermo Scientific 75003663 F15 8x50c 2 1 2 Accessories Thermo Scientific General Purpose Rotors F15 8x50c Carbon Fiber Rotor 15 8 50 Fixed Angle Carbon Fiber Rotor Rotor Specifications Capacity ml 8 x 50 conical Tube Dimensions mm 30 x 121 Angle 25 Maximum Speed rpm 14 500 K Factor 1 062 Net Weight kg 44 RCF Radius RCF x g Radius cm Maximum 24 446 10 4 Minimum 10 098 4 3 F15 8x50c Carbon Fiber Rotor Cat No Description 75003663 F15 8x50c Carbon Fiber Rotor Cat No Description 099 085077 Replacement Lid Assembly 021 085077 O ring Refresher Kit Tube Ordering Information Sealing Assembly Required Adapters Require
32. ntific 75003663 F15 8x50c 5 1 5 Aerosol tight Applications Basic Principles Basic Principles CAUTION When centrifuging hazardous samples do not open aerosol tight rotors or buckets unless placed in a safety cabinet Always bear in mind the maximum permitted fill levels Be sure to check all seals before starting any aeorsol tight applications Check that the sample containers are well suited for the desired centrifugation process Fill Level The tubes are only to be filled to a level which ensures that the sample is unable to reach the top of the tube during centrifugation Therefore fill the tube only 2 3 of the rated level Checking the Aerosol Tightness The aerosol tightness testing of the rotors and buckets depend on the microbiological test process in accordance with the EN 61010 2 020 Appendix AA Whether or not a rotor is aerosol tight depends primarily on proper handling Check as needed to make sure your rotor is aerosol tight The careful inspection of the seals and seal surfaces for signs of wear and damage such as cracks scratches and embrittlement is extremely important Aerosol tight applications are not possible if the lids are open Aerosol tightness requires the correct operation when filling the sample vessels and closing the rotor lid Quick Test As a quick test it is possible to test the aerosol tightness of fixed angle rotors using the following process 1 Lubricate all seals lightly Al
33. phate U 5 5 5 5 5 5 5 5 SSM 5 5 5 5 5 5 MS 5 5 Ammonium Sulfate UMS 5 5 0 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 US SU Alcohol 5 MU 5 5 5 MS 5 5 U S M Aniline S 5 UU 5 US MS U U U U 0 0 0 5 MU 0 5 5 5 5 US Sodium Hydroxide lt 1 U MS 5 S SMS 5 SMMS 5 5 5 5 5 MS 5 U Sodium Hydroxide 10 U MU U MMS 5 US 5 5 5 5 5 SMS 5 U Barium Salts MU 5 5 5 5 5 5 5 5 5 5 5 5 5 5 MS 5 5 Benzene S88UuusuMusuusuuuMuMUuuusuusus Thermo Scientific 75003663 F15 8x50c B 1 Chemical Compatibility Chart CHEMICAL ANODIC COATING for ALUMINUM COMPOSITE Carbon Fiber Epoxy POLYURETHANE ROTOR PAINT MATERIAL GLASS NORYL POLYSULFONE STAINLESS STEEL TYGON Benzyl Alcohol cc CELLULOSE ACETATE BUTYRATE Boric Acid lt PET POLYCLEAR CLEARCRIMP CCCLEARCRIMP co C POLYESTER GLASS THERMOSET ETHYLENE PROPYLENE c POLYTHERMIDE Cesium Acetate Cesium Bromide Cesium Chloride Cesium Formate Cesium lodide Cesium Sulfate Chloroform C CO nj CO co C vj vj mj mi cO SIICONERUBBER mi mij mj mj mj mj mj lt co Chromic Acid 10 AM cj aj mM ci mi cO NEOPRENE mi mij mj mj mj mj mj mi co vi lt co CO 0 C C vj co nj mj mj mj mj ci co mij mj mj mj Chromic Acid 50 Cresol Mixture Cyclohexane Deoxycholate Distilled Water Dex
34. published specifications when subjected to normal proper and intended usage by properly trained personnel for a period of 5 YEARS after shipment to the Customer the Warranty Period Thermo Fisher Scientific agrees during the Warranty Period provided it is promptly notified in writing upon the discovery of any material defect and further provided that all costs of returning the defective Goods to Thermo Fisher Scientific are pre paid by the Customer to repair or replace at Thermo Fisher Scientific s option defective Goods so as to cause the same to oper ate in substantial conformance with the said specifications Replacement parts may be new or refur bished at the election of Thermo Fisher Scientific All replaced parts shall become the property of Thermo Fisher Scientific Thermo Fisher Scientific s sole liability with respect to equipment materials parts or software furnished to Thermo Fisher Scientific by its third party suppliers shall be limited to the assignment by Thermo Fisher Scientific to the Customer of any such third party supplier s war ranty to the extent the same is assignable In no event shall Thermo Fisher Scientific have any obliga tion to make repairs replacements or corrections required in whole or in part as the result of i normal wear and tear ii accident disaster or event of force majeure iii misuse fault or negligence of or by or on behalf of the Customer iv use of the Goods in a manner for w
35. tran C1 QI ml WM WM Cl WM WM CI QI QI WN WN z c c c z zi z 2 v Ci nA WD nj nj co mi mij mj mj mij co mi mj mj mj co mi mj mj mij co ci vi nj nj ci Diethyl Ether ci n Diethyl Ketone ci n gt ci n Diethylpyrocarbonate Dimethylsulfoxide ci cj c c ci nj nj cj cj zj zj cj nj nj nj nj mal c POLYCARBONATE c cj C ci vj wn zc nj nj C cc c cl POLYVINYL CHLORIDE mj ml nl nl nl CA nl nm ni ni RULONA TEFLON cl cj oj cj Dioxane co Ferric Chloride Acetic Acid Glacial e lt Acetic Acid 5 co Acetic Acid 6096 Ethyl Acetate nlc o nlc Ethyl Alcohol 5096 zj nj cj wm c gj lt lt mj mj nj nj CO mj mj nj nj nja Mm mj mj nj nj c Ethyl Alcohol 95 C C C C C Z c Ethylene Dichloride oj vl co c zj nj vj nj c zj nj vj ni nj coo nj nj c c c z zi ALUMINUM vj nj c c Z c c c c co nj c cl c ajaj aj a a c BUNAN co C ZI C nj nj cl cil an DELRIN ceo mj ml mj C nj cj mj nj mj n
36. ways use the special grease 7600 3500 when lubricating the seals 2 Fill the cavities with approx 10 ml of carbonated mineral water 3 Close the rotor as explained in the handling instructions 4 Shake the rotor vigorously using your hands This releases the carbonic acid gas which is bound in the water resulting in excess pressure Do not apply pressure to the lid when doing so Leaks can be detected by escaping water or the sound of escaping gas 5 2 75003663 F15 8x50c Thermo Scientific 5 Aerosol tight Applications Checking the Aerosol Tightness Replace the seals if you detect any leaks Then repeat the test 5 Dry the rotor rotor lid and the cover seal CAUTION Prior to each use the seals in the rotor are to be inspected in order to assure that they are correctly seated and are not worn or damaged Damaged seals are to be replaced immediately When loading the rotor ensure that the rotor lid closes securely Damaged or clouded rotor covers are to be replaced immediately Thermo Scientific 75003663 F15 8x50c 5 3 5 Aerosol tight Applications Checking the Aerosol Tightness 5 4 75003663 15 8 50 Thermo Scientific Maintenance and Care Thermo Scientific 75003663 F15 8x50c 6 1 B Maintenance and Care Intervals Intervals For the sake of personal environmental and material protection it is your duty to clean and if necessary disinfect the rotor on a regular basis Maintenance Recommended interva