Contents

1. Lower shell Vaccum cushion in Upper shell Vakuumkissen anpassen und fixieren Coque inf rieure fabric liner Coque Adjusting and fastening the vacuum cushion Supporto Garniture sup rieure Adapter et fixer le coussin sous vide rigido inferiore Rivestimento Supporto Regolazione e fissaggio del cuscino sottovuoto rigido EI Pumpe aufsetzen und mehr superiore mals dr cken Ventil schlie en RS Attach gray end of pump to circular end of valve Pump repeatedly until pump no longer inflates Close the valve cap Mettre en place la pompe et appuyer plusieurs fois fermer la soupape ES Applicare la pompa e premere ripetutamente chiudere la valvola www vacoped com Ventilfunktionen Valve functions Fonctionnement de la soupape Funzioni della valvola Vakuumkissen wird weich To make the vacuum cushion soft Le coussin sous vide devient mou Il cuscino sottovuoto diventa morbido DJ Ventilring nach oben ziehen und seitlich bewegen damit Luft einstr men kann ES Pull the valve ring outwards and bend it left or right to allow air to enter Tirer l anneau de soupape vers le haut et la d placer lat ralement afin que l air puisse entrer ES Tirare l anello della valvola verso l alto e muoverlo lateralmente per permettere l afflusso dell aria Vakuumkissen wird fest To make the vacuum cushion rigid Le coussin sous vide devient dur Il cuscino diventa rigido IJ Ventilring nach unten dr cken und mit der Pum
2. E Top screw sets plantar flexion limit downward mobility of forefoot vis sup rieure but e pour la flexion plantaire tirement de la pointe du pied ER Vite superiore battuta per flessione plantare postura del piede equino DJ untere Schraube Anschlag f r Dorsalextension Heben der FuRspitze E Bottom screw sets dorsal extension limit upward mobility of forefoot vis inf rieure but e pour l extension dorsale redressement de la pointe du pied Untere Schraube Bottom screw ER Vite inferiore battuta per estensione Bee dorsale sollevamento della punta del piede vis inf rieure Vite inferiore www vacoped com Winkeleinstellung andern Adjusting the angles Modifier le r glage de l angle Modifica dell impostazione dell angolo El Schl ssel aus der Halterung nehmen und in die Schraube stecken RS Take the key out of its mounting and insert it in the screw Retirer la cl de la fixation et l ins rer dans la vis ES Estrarre la chiave dal supporto e inserirla nella vite Schl ssel Key Cl Chiave IG Hinweis bei einer Winkeleinstellung von 10 bis 30 bitte Keilsohle verwenden BEI Note Please use the wedge sole for settings from 10 to 30 Remarque pour un r glage d angle de 10 a 30 utiliser une semelle compens e ES Avvertenza con un impostazione dell angolo di 10 sino 30 utilizzare una suola compensata Winkeleinstellung andern Adj
3. 4 42 Greenacre Rd Wollongong NSW 2500 Australia Phone 61 0 2 4226 5880 Fax 61 0 2 4226 5881 contact oped australia com au www oped com au OPED USA 203 Crescent Street Suite 205 Waltham MA 02453 USA Phone 1 877 673 3426 Fax 1 781 891 6735 hello opedusa com www opedusa com www vacoped com Anlegevorgang D Application procedure VACOped anlegen Applying VACOped Proc dure de mise en place Mettre en place VACOped Applicazione di VACOped Procedura di appl icazione E Ventilring nach oben ziehen siehe Ventilfunktion FUR in Stoffbezug einsetzen Stoffbezug schlieRen Obere Abdeckung aufsetzen Gurte schlie en RS Pull the valve ring outwards see valve function Place your foot into the fabric inner boot Close the fabric cover With the inner boot Ventil on step into the lower shell Place the upper shell over the front of the fabric cover fasten the straps Valve Tirer l anneau de soupape vers le haut voir fonctionnement de la Valvola soupape Ins rer le pied l int rieur de la garniture en tissu fermer la Soupape garniture en tissu Reihenfolge Poser la coque sup rieure Sequence fermer les sangles Ordre ES Tirare l anello della valvola verso l alto vedere funzioni della valvola Inserire il piede nel rivestimento in tessuto chiudere il rivestimento in tessuto Applicare la copertura superiore fissare le cinghie Sequenza Unterschale Bezug Oberschale
4. dans la nouvelle garniture ins rer la soupape dans l orifice pr vu cet effet ES Aprire completamente la cerniera posteriore estrarre il cuscino sottovuoto morbido e distribuire l imbottitura uni formemente con la mano Inserire nuovamente il cuscino sottovuoto rigido vedere funzioni della valvola nel nuovo rivestimento facendo passare la valvola attraverso l occhiello www vacoped com Sohle montieren und wechseln Attaching and removing the sole Mettre en place et changer la semelle Montaggio e sostituzione della suola Sohle abnehmen Removing the sole Retirer la semelle Rimozione della suola BD Beide Entriegelungskn pfe gleichzeitig dr cken BE Press both release buttons simultaneously Appuyer simultan ment sur les deux boutons de d verrouillage ES Premere contemporaneamente i due pulsanti di sblocco Sohle anlegen Attaching the sole Mettre en place la semelle Applicazione della suola DJ VACOped gerade und mittig auf die Sohle setzen VACOped gegen die Sohle dr cken zwei Klicks ert nen EX Place the bottom of VACOped directly into the center of the sole Press the VACOped against the sole until two clicks are heard Placer VACOped dans la position debout sur la semelle et appuyer deux clics doivent retentir ES Posizionare VACOped diritto e al centro della suola premendolo contro di essa fino a sentire due clic Sohlenlange anpassen Adjusting the length of
5. Caratteristiche del prodotto e Ambidestro e Misure Small Medium Large EUR 35 39 39 44 44 50 UK 2 5 45 10 9 16 US M 2 5 5 10 10 16 USW 4 8 7 13 12 15 Indicazioni Modalita d impiego Fratture al piede o all articolazione tibio tarsica Frattura del calcagno Rottura del tendine di Achille Tecnica protesica Artrodesi Gravi lesioni ai legamenti Problemi e soluzioni Punti di pressione e Ripetere la procedura di regolazione e Distribuire uniformemente l imbottitura del cuscino nel punto di pressione Se dopo ripetute modifiche della regolazione permangono dolori insensibilit delle dita o colorazione bluastra dei piedi rivolgersi tempestivamente a un medico necessario l intervento di personale sanitario Per ulteriori consigli visitare il sito www vacoped com Avvertenze di sicurezza Controindicazioni e Accertarsi che la suola sia fissata saldamente pericolo di scivolamento e Non sono note controindicazioni VACOped non stato progettato per resistere a carichi dinamici come quelli che si sviluppano quando si salta o si cammina a passo svelto Inoltre urti di qualunque genere possono comprometterne la sicu rezza Verificare immediatamente se VACOped ha subito danni ogni volta che lo si ritiene necessario VACOped deve essere utilizzato esclusivamente per il trattamento di lesioni al piede e alla caviglia Dati tecnici Parametri Materiali utilizzati Supporti rigidi PP rivestimenti
6. the sole Adapter la longueur de semelle Regolare la lunghezza della suola EJ Sohle abnehmen siehe Sohle montieren Entriegelungsknopf dr cken Zehenst ck auf die gew nschte L nge ziehen EI Remove the sole see removing the sole Press the release button Pull the toe piece to the required length Retirer la semelle voir mettre en place et changer la semelle Appuyer sur le bouton de d verrouillage R gler la partie orteils la longueur souhait e EN Rimozione della suola vedere montaggio della suola Premere i pulsanti di sblocco Estrarre il supporto per le dita fino alla lunghezza desiderata Wadenumfang anpassen Adjusting the calf circumference Adapter le volume du mollet Regolazione della circonferenza del polpaccio GX Schnalle aus der Wadenschale dr cken EX Press the clasp to release it from the calf shell Retirer la boucle de la coque du mollet en appuyant dessus ES Premere la fibbia per staccarla dal supporto rigido del polpaccio BD Schnalle an die gew nschte Position schieben BEI Push the clasp into the desired position Pousser la boucle dans la position souhait e RS Spingere la fibbia nella posizione desiderata Gi grofter Wadenumfang Large calf circumference kleiner Wadenumfang Small calf circumference grand volume de mollet petit volume de mollet Circonferenza del polpaccio maggiore Circonferenza del polpaccio minore DI Schn
7. Fu und Sprunggelenk Calcaneusfraktur Achillessehnenruptur Prothetik Arthrodesen Schwere Bandverletzungen Problem amp L sung Druckstellen e Anpassvorgang wiederholen e Kissenf llung an der Druckstelle gleichm ig verstreichen Sollten sich Schmerzen Taubheit der Zehen oder blau angelaufene F e nicht durch wiederholtes Anpassen beseitigen gehen Sie sofort zum Arzt Hier ist eine medizinische Nachsorge notwendig Zahlreiche Tipps und Tricks finden Sie unter www vacoped com Sicherheitshinweise Kontraindikationen e berpr fen Sie den festen Sitz der Sohle Rutschgefahr e Kontraindikationen sind keine bekannt VACOped ist nicht f r dynamische Belastungen wie beim Springen und schnellem Gehen ausgelegt St rze aller Art k nnen zudem die Sicherheit beeintr chtigen berpr fen Sie Ihren VACOped gegebenenfalls umgehend auf Besch digungen VACOped dient der ausschlie lichen Behandlung von Verletzungen des Fu es und Sprunggelenks Technische Daten Parameter Verwendete Materialien Hartschalen PP Bez ge Baumwolle PU Schaumstoff Kissen H lle PVC F llmaterial EPS Kugeln Vordere Abdeckung PP PU Gurte PP Gewebe Laufsohle EVA e Gewicht 2 800 g Abmessungen 58x37x18 cm Gew hrleistung Die Gew hrleistung entspricht den gesetzlichen Vorgaben CE Useful Details Cleaning and care e Shell and straps Shell dishwasher 60 C 140 F straps washing machine 40 C 104 F e
8. OPED bewegt Wir von der Firma OPED sind Experten der Medizintechnik Unsere orthop dischen Rehabilitationsprodukte sind eigene Erfindungen und werden in Deutschland gefertigt Unser Ziel Ein beweglicher Patient www oped de OPED gets you moving We at OPED are experts in medical technology We develop all our orthopedic rehabilitation products in house and manufacture them in Germany Our goal A mobile patient www oped de En plein mouvement grace a OPED Chez OPED nous sommes experts en technologie m dicale Nous concevons et fabriquons nous m mes nos produits de r ducation ortho p dique en Allemagne Notre objectif un patient parfaitement mobile www oped de OPED mobilita Noi della ditta OPED siamo esperti in apparecchiature medicali nostri prodotti di riabilitazione ortopedica sono frutto della nostra inventiva e sono fabbricati in Germania Il nostro obiettivo la mobilita del paziente www oped de OPED GmbH Medizinpark 1 83626 Valley Oberlaindern Germany Fon 49 0 8024 6081 8 210 Fax 49 0 8024 6081 8 299 mail oped de www oped de OPED AG Hinterbergstrasse 26 6330 Cham Switzerland Fon 41 0 41 748 53 35 Fax 41 0 41 748 53 40 contact oped ch www oped ch OPED UK Ltd Unit 2 Glenmore Business Centre Waller Road Hopton Industrial Estate Devizes SN10 2EQ United Kingdom Phone 44 0 1380 722177 Fax 44 0 1380 710095 enquiries oped biz www opeduk co uk OPED Australia Pty Ltd
9. Terry cloth covers washing machine 60 C 140 F close the zipper first e Vacuum cushion use disinfectant wipe or disinfectant spray e Storage store in a dry place Product features e Can be worn on the right or left foot e Sizes Small Medium Large EUR 35 39 39 44 44 50 UK 2 5 45 10 9 16 US M 2 5 5 10 10 16 US W 4 8 75 13 12 15 Indications types of use Fractures of the foot and ankle joint Calcaneus fractures Achilles tendon rupture Prosthetics Arthodesis Severe ligament injuries Troubleshooting Tender spots e Remove boot completely Put air back in vacuum cushion Shake cushion to redistribute beads Re apply boot e Place air back in vacuum cushion Locate area on vacuum cushion that is source of tenderness and use fingers to ensure beads are between tender spot and outer shell If repeated adjustment does not remedy the pain or numbness in the toes or feet and or skin turns bluish call your doctor immediately Medical aftercare is necessary in this case You will find numerous tips and tricks at www vacoped com Safety notices contraindications e Check that the sole is properly attached to bottom of boot If not remove and re apply e There are no known contraindications VACOped is not designed for dynamic loads such as jumping or fast walking Furthermore falls of any kind can compromise the safety Whenever appropriate check your VACOped for damage immedia tely VACOped s only in
10. adaptations consultez sans d lai votre m decin Dans ce cas un suivi m dical est indispensable Vous trouverez de nombreux conseils et astuces sur www vacoped com Consignes de s curit contre indications e V rifier que la semelle soit solidement fix e risque de glissade e Aucune contre indication n est connue ce jour VACOped n est pas concu pour supporter des charges dynamiques comme le saut ou la marche rapide Toute chute quelle qu elle soit risque en outre de compromettre la s curit S il y a lieu v rifiez imm diatement tout signe de dommage sur votre VACOped Le VACOped est exclusivement destin au traitement des blessures au pied et la cheville Caract ristiques techniques param tres Mat riaux utilis s Coques rigides PP garnitures coton mousse PU housse des coussins PVC mat riau de remplissage billes de PSE coque avant PP PU sangle tissu PP semelle EVA Toutes les pi ces et tous les composants sont exempts de latex e Poids 2 800g e Dimensions 58x37x18 cm Garantie Les garanties sur les produits correspondent aux prescriptions en vigueur CE Dettagli utili Pulizia e manutenzione e Supporto rigido e cinghie Supporto rigido in lavastoviglie 60 C cinghie in lavatrice 40 C e Rivestimenti in spugna in lavatrice 60 C chiudere la chiusura a cerniera e Cuscino sottovuoto strofirare con un disinfettante e Conservazione conservazione in luogo asciutto
11. alle in das gew nschte Loch dr cken Vorgang auf der anderen Seite wiederholen EI Press the clasp into the desired hole Repeat the procedure on the other side Ins rer la boucle par pression dans le trou souhait Fress R p ter la proc dure pour l autre c t ES Premere la fibbia nel foro desiderato Ripetere la procedura sull altro lato www vacoped com Winkeleinstellung Angle adjustment R glage de l angle Regolazione dell angolo Fixiertes Sprunggelenk FIX Einstellung Fixed ankle joint immobilized adjustment Articulation fixe de la cheville r glage FIX Articolazione tibio tarsica fissa regolazione FIX DJ Einstellung in 5 Schritten von 15 bis 30 m glich Skala der Grad einstellung 1 entspricht 10 RS Immobilization is possible in 5 increments from 15 up to 30 Level 1 is equivalent to 10 degrees R glage par pas de 5 possible de 15 a 30 Echelle pour le r glage en degr s 1 correspond a 10 BS La regolazione pu essere effettuata a intervalli di 5 da 15 a 30 Scala per la regolazione dei gradi 1 corrisponde a 10 Bewegliches Sprunggelenk ROM Einstellung Obere Schraube Flexible ankle joint ROM adjustment Top screw Articulation mobile de la cheville r glage ROM vis sup rieure Articolazione tibio tarsica mobile impostazione ROM Vite superiore E obere Schraube Anschlag f r Plantarflexion SpitzfuRstellung
12. cotone schiuma PU involucro del cuscino PVC materiale di riempimento sfere in EPS copertura anteriore PP PU cinghie tessuto in PP suola EVA Tutte le parti e i componenti sono privi di lattice e Peso 2 800 g e Dimensioni 58x37x18 cm Garanzia La garanzia del prodotto conforme ai requisiti di legge C
13. pe Vakuum ziehen Anpassung fixieren GI Press the valve ring down attach the bulb pump to the end of the valve and pump until pump no longer inflates Pousser l anneau de soupape vers le bas et faire le vide avec la pompe Fixer l adaptation ES Premere l anello della valvola verso il basso creando il vuoto con la pompa Fissare la regolazione Ventilkappe schlieRen Close the valve cap Fermer le bouchon de la soupape Chiudere il cappuccio della valvola BJ Sichern des Vakuumzustandes ES Ensures that valve stays closed Assure l tanch it ES Assicurare lo stato di vuoto Kissenbezug wechseln Changing the cushion cover Changer la garniture du coussin Cambiare il rivestimento del cuscino DJ Hinteren Reissverschluss ganz ffnen Vakuumkissen heraus nehmen Vakuumkissen weich mit der Hand gleichm ig verstreichen Vakuumkissen fest siehe Ventilfunktionen wieder in den neuen Bezug einlegen Ventil durch das Knopf loch stecken ES Open the back zip completely Remove the vacuum cushion Make cushion soft by opening valve Smooth out the vacuum cushion with your hand Pump out air to make vacuum cushion hard Put the vacuum cushion back into the new cover and insert the valve through the buttonhole Ouvrir totalement la fermeture clair arri re retirer le coussin sous vide uniformiser le contenu du coussin mou manu ellement ins rer nouveau le coussin dur voir fonctionnement de la soupape
14. tended use is the treatment of injuries to the foot and ankle Technical Data Packing Dimensions Materials used Hard shells PP covers cotton PU foam cushion cover PVC padding material EPS balls top cover PP PU straps PP material outer sole EVA All parts and components are latex free Packaging e Weight including product 2 800g 6 Ibs 2 oz e Dimensions 58x37x18 cm 23 x14 6 x7 Warranty The product warranties comply with all legal regulations C www vacoped com Notice Nettoyage et entretien Coque et sangle Coque Lave vaisselle 60 C sangle machine laver 40 C e Garniture ponge Machine laver 60 C fermer au pr alable la fermeture clair e Coussin sous vide chiffon d sinfectant e Stockage stocker sec Caract ristiques du produit e Utilisable pour la jambe gauche comme pour la jambe droite e Dimensions Small Medium Large EUR 35 39 39 44 44 50 UK 2 5 45 10 9 16 US M 2 5 5 10 10 16 US W 45 8 75 13 1257 15 Indications utilisation Fracture du pied et de la cheville Fracture du calcan us Rupture du tendon d Achille Proth tique Arthrod se L sion s v re du ligament Probl mes et solutions Empreintes e R p ter la proc dure d adaptation Uniformiser le remplissage du coussin au niveau de l empreinte En cas de douleur d engourdissement des orteils ou de coloration bleue du pied qui ne seraient pas solutionn s apr s plusieurs
15. usting the angles Modifier le r glage de l angle Modifica dell impostazione dell angolo DJ Schl ssel waagerecht drehen E Turn the key until it s in a horizontal position Tourner la cl horizontalement ES Ruotare la chiave in posizione orizzontale DJ Schraube anheben und an die gew nschte Position schieben EA Lift the screw and move it until it sits in the desired position Soulever la vis et la placer dans la position souhait e EN Sollevare la vite spingendola nella posizione desiderata DJ Schl ssel senkrecht drehen Die obigen Schritte mit der anderen Schraube wiederholen BEI When screw has been appropriately adjusted lock it into position by turning it into a vertical position Repeat procedure to adjust lower screw Tourner la cl verticalement R p ter l tape ci dessus avec l autre vis RS Ruotare la chiave in posizione verticale Ripetere la sequenza appena descritta con l altra vite www vacoped com Kleingedrucktes Reinigung und Pflege e Schale und Gurte Schale Sp lmaschine 60 C Gurte Waschmaschine 40 C e Frotteebez ge Waschmaschine 60 C Reissverschluss vorher schlieRen e Vakuumkissen Wischdesinfektion e Lagerung trocken lagern Produkteigenschaften e Rechts und links tragbar e Gr en Small Medium Large EUR 35 39 39 44 44 50 UK 2 5 4 10 9 16 US M 27 575 5 10 10 16 US W 4 8 75 13 12 15 Indikationen Einsatzorte Frakturen am