Home

WINDY BOY 3000TL / 3600TL / 4000TL / 5000TL

image

Contents

1. Wind Power Inverter WINDY BOY 3000TL 3600TL 4000TL 5000TL User Manual WB3 5TL 21 BA en 10 TBEN WB3 5TL 21 Version 1 0 SMA Solar Technology Table of Contents Table of Contents GO A Information on this 5 LE EE sedo ines ed eei adds 7 23 Intended Users e edd etre RT 7 2 2 Safety Precautions e oe re 8 Product Description 9 Windy NSE RETRY RA 9 92 ew 11 339 Label Seed 14 3A Bluetooth NE ES 16 3 5 Slot for Communication Interface 16 3 6 Slot for Multi Function 17 LED Signal ai PTT 18 Cleaning the 19 Glossary sos exa etes cxtat ab ee RE hant dona rdg 20 Contad 21 WB3 5TL 2 1 BA en 10 3 Table of Contents SMA Solar Technology AG 4 WB3 5TL 2 1 BA en 10 User Manual 5 Solar Technology AG Information on this Document 1 Information on this Document Validity This document is valid for the following devices types as of firmware version 2 10 e WB 3000TL21 e WB 3600TL21 e WB 4000TL21 e WB 5000TL21 Target Group This document is intended for end users Symbols Symbol Explanation DANGER Indicates hazardous situa
2. NetID the set country data set and display language Telephone receiver Indicates that an error cannot be rectified on site Contact installer Spanner Indicates an error that can be rectified on site by your installer Contact installer Bluetooth Indicates that an active Bluetooth connection is established Bluetooth connection quality Indicates the quality of the Bluetooth connection to other Bluetooth devices Je Speedwire If a Speedwire data module is installed in the inverter this symbol shows that there is a connection to a network 12 WB3 5TL 2 1 BA en 10 User Manua SMA Solar Technology 3 Product Description Symbol c Description Webconnect function Explanation If a Webconnect data module is installed in the inverter this symbol shows that connection to Sunny Portal is possible Q Multi function relay Indicates that the multifunction relay is active Thermometer Indicates that the power of the inverter is limited due to excessive temperature Power limitation Indicates that the external active power limitation via the plant control is active Small wind turbine system with rectifier EJ gt Inverter ot Grid relay A closed grid relay indicates that the inverter is feeding into the electricity grid An open grid relay shows that the inverter is disconnected from the electricity grid Electricity g
3. line conductor the displayed values are assigned to F Event number relating Event number of errors relating to the electricity to the electricity grid grid G Output voltage Alternates between output voltage and output output current current of a line conductor H Event number relating Event number of errors relating to the inverter to the inverter User Manual WB3 5TL2 1 BA en 10 11 3 Product Description SMA Solar Technology AG Position Description Explanation Input voltage input Alternates between input voltage and input current current of one input K Event number relating Event number of errors relating to the small wind to the small wind turbine system turbine system L Text line Displays the event message or error message M Power and yield curve Changes in power over the last 16 feed in hours or the energy yields over the last 16 days e In order to switch between the displays tap once on the enclosure lid Symbols on the Display Symbol N E Description Tapping Explanation You can operate the display by tapping on the enclosure lid Tap once to activate the backlight to scroll to the next text line to switch between the power graphs of the last 16 feed in hours and the energy yields of the last 16 days Tap twice in succession the display successively shows the firmware version the serial number or designation of the inverter Bluetooth
4. Avoid contact during operation Observe the documentation Observe all documentation that is supplied with the product DC DC Direct current Without transformer The product does not have a X transformer AC AC Alternating current WEEE designation Do not dispose of the product together with household waste but in accordance pum with the locally applicable disposal regulations for electronic waste C CE marking The product complies with the requirements of the applicable EC directives Device class ID The product is equipped with a wireless component and complies with device class 2 Degree of protection The product is protected against dust intrusion and water jets from any angle Outdoor The product is suitable for outdoor installation Solar RAL quality mark for solar products The product complies with the requirements of the German Institute for Quality Assurance and Certification User Manual WB3 5TL 21 BA en 10 15 3 Product Description SMA Solar Technology AG Symbol Description Explanation Certified safety The product is VDE tested and complies DE with the requirements of the German Equipment and Product Safety Act Quen C Tick The product complies with the requirements of the applicable Australian EMC standards 3 4 Bluetooth The inverter is equipped with Bluetooth inte
5. MA de User Manual WB3 5TL2 1 BA en 10 21 SMA Solar Technology AG Legal Restrictions Legal Restrictions The information contained in this document is the property of SMA Solar Technology AG Publishing its content either partially or in full requires the written permission of SMA Solar Technology AG Any internal company copying of the document for the purposes of evaluating the product or its correct implementation is allowed and does not require permission SMA Factory Warranty The current warranty conditions come enclosed with your device These are also available online at www SMA Solar com and can be downloaded and are available on paper from the usual sales channels if required Trademarks All trademarks are recognized even if these are not marked separately Missing designations do not mean that a product or brand is not a registered trademark The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG Inc and any use of such marks by 5 Solar Technology AG is under licence QR Code is a registered trademark of DENSO WAVE INCORPORATED SMA Solar Technology AG Sonnenallee 1 34266 Niestetal Germany Tel 49 561 9522 0 Fax 49 561 9522 100 www SMA de E Mail info SMA de 2004 to 2012 SMA Solar Technology All rights reserved User Manual WB3 5TL2 1 BA en 10 23 SMA Solar Technology SMA Solar Technology AG www SMA de SMA Australia Pty Ltd www SMA Australia com au
6. SMA Benelux bvba sprl www SMA Benelux com SMA Beijing Commercial Company Ltd www SMA China com cn SMA Central 8 Eastern Europe s r o www SMA Czech com SMA France S A S www SMA France com SMA Hellas AE www SMA Hellas com SMA Ib rica Tecnolog a Solar S L U www SMA Iberica com SMA Solar India Pvt Ltd www SMA India com SMA Italia S r l www SMA ltalia com SMA Japan www SMA Japan com SMA Technology Korea Co Ltd www SMA Korea com SMA Middle East LLC www SMA Me com SMA Portugal Niestetal Services Unipessoal Lda www SMA Portugal com SMA Solar Thailand Co Ltd www SMA Thailand com SMA Solar UK Ltd www SMA UK com
7. e rectified alternating current generated by the small wind turbine system or other energy converters based on permanent magnet generators into grid compatible alternating current and feeds this into the electricity grid or stand alone grid Load resistor Small Wind Turbine System Windy Boy Power distribution grid Figure 1 Structure of a small wind turbine system with Windy Boy The Windy Boy is suitable for indoor and outdoor use Alternative uses of the Windy Boy not expressly recommended by SMA Solar Technology AG are not permitted For safety reasons it is not permitted to modify the product or install components that are not explicitly recommended or distributed by SMA Solar Technology AG for this product The enclosed documentation is a part of this product Read and adhere to the documentation Keep the documentation in a convenient place for future reference User Manual WB3 5TL 2 1 BA en 10 7 2 Safety SMA Solar Technology AG 2 2 Safety Precautions Electric Shock High voltages are present in the live components of the inverter Touching these components can cause fatal electric shocks Do not open the inverter All work on the inverter e g repairs modifications must be carried out by skilled persons only Burn Hazards Some parts of the enclosure can become hot during operation During operation only touch the lower enclosure lid Do not place any objects on the enclosure as th
8. ht of each other Energy Energy is the power that a system can supply or consume within a certain time unit Energy is measured in Wh watt hours If for instance your inverter feeds in for half an hour at 3 000 W and half an hour at 2 000 W it will have fed a total of 2 500 Wh into the electricity grid Power Power is the product of voltage and electrical current strength Power is measured in watts The power shown in the display is an instantaneous value It indicates the power that your inverter is currently feeding into the electricity grid 20 WB3 5TL2 1 BA en 10 User Manual SMA Solar Technology 7 Contact 7 Contact If you have technical problems first contact your installer The following information is required in order to provide you with the necessary assistance Inverter device type Inverter serial number Firmware version of the inverter Special country specific settings of the inverter if applicable Type and number of small wind turbine systems connected Installation location and installation altitude of the inverter Three digit or four digit event number and display message of the inverter Optional equipment e g communication products Use of the multifunction relay if available SMA Solar Technology AG Sonnenallee 1 34266 Niestetal Germany www SMA de SMA Service Line Inverters 49 561 9522 1499 Communication 49 561 9522 2499 Fax 49 561 9522 4699 E Mail Serviceline8S
9. is can lead to yield losses Inverter Damage Overvoltages can destroy the inverter f the display message DC overvoltage Disconnect generator is shown inform your installer IMMEDIATELY The inverter can be damaged by removing the ESS under load e Always leave the ESS plugged in during operation 8 WB3 5TL 2 1 BA en 10 User Manual SMA Solar Technology 3 Product Description 3 Product Description 3 1 Windy Boy The Windy Boy is a transformerless wind energy inverter which converts the rectified alternating current generated by the small wind turbine system into grid compatible alternating current and feeds this into the electricity grid or stand alone grid A Figure 2 Design of the Windy Boy Position Description A Cooling fins B Type label LEDs D Display E Electronic Solar Switch 55 F Lower enclosure lid G Upper enclosure lid Always leave the ESS plugged in during operation The ESS must only be removed by a skilled person in order to ensure that no voltage is present in the inverter User Manual WB3 5TL 2 1 BA en 10 9 3 Product Description Symbols on the Inverter SMA Solar Technology AG Symbol Description Inverter Explanation This symbol defines the function of the green LED The green LED indicates the operating state of the inverter Observe the documentation This symbol defines the function of the
10. or messages for example SMA Power Control Module The SMA Power Control Module enables the inverter to implement grid management and is also equipped with a multi function relay Fan Retrofit Kit The fan retrofit kit provides additional cooling of the inverter in the event of high ambient temperatures and is likewise equipped with a multifunction relay The fan retrofit kit and the SMA Power Control Module cannot be operated in parallel User Manual WB3 5TL 2 1 BA en 10 17 4 LED Signals SMA Solar Technology AG 4 LED Signals The LEDs indicate the operating state of the inverter Description Status Explanation Green LED Glowing Operation Flashing Requirements for connection to the electricity grid have not been met Red LED Glowing Failure Contact installer Blue LED Glowing Bluetooth communication is activated 18 WB3 5TL 2 1 BA en 10 User Manual SMA Solar Technology AG 5 Cleaning the Inverter 5 Cleaning the Inverter NOTICE Damage to the display by use of cleaning agents If the inverter is dirty clean the enclosure lid the display and the LEDs using only clean water and a cloth User Manual WB3 5TL2 1 BA en 10 19 6 Glossary SMA Solar Technology AG 6 Glossary Bluetooth Bluetooth is a radio technology that allows the inverter and other communication products to communicate with each other For Bluetooth communication the Bluetooth devices do not need to be within sig
11. red LED The red LED indicates an error Contact installer Bluetooth This symbol defines the function of the blue LED The blue LED indicates that communication via Bluetooth is activated o unnydots com GR Code By scanning this code the solar power professional installing the inverter can register the inverter and take part in the SMA bonus programme Danger If a second protective conductor is required the enclosure must be additionally earthed 10 WB3 5TL 2 1 BA en 10 User Manual SMA Solar Technology 3 Product Description 3 2 Display The display shows the current operating data of the inverter e g current power daily energy total energy as well as events or errors The power and energy are displayed as bars in the diagram The display values may deviate from the actual values and must not be used for billing purposes The values measured by the inverter are required for the operational control and to control the current to be fed into the electricity grid LICL Figure 3 Design of the display example Position Description Explanation A Power Current power B Day Daily energy Total Total amount of energy fed in until now D Active functions The different symbols indicate which functions for communication grid management or temperature derating are enabled or active E Line conductor Indicates which
12. rface as standard and can communicate with special SMA communication products or other inverters for information on supported products see www SMA Solar com If you wish to communicate via Bluetooth you can protect the inverter with a plant password for the user All inverters are delivered with a default plant password for the user 0000 as standard To protect the plant from unauthorised access you must change the default plant password for the user using Sunny Explorer for information on changing the plant password refer to the Sunny Explorer help 3 5 Slot for Communication Interface The inverter can optionally be fitted with an extra communication interface e g 85485 This communication interface enables the inverter to communicate with special 5 communication products for information on supported products see www SMA Solar com The communication interface can either be retrofitted or installed ex works according to a specific order 16 WB3 5TL2 1 BA en 10 User Manual SMA Solar Technology AG 3 Product Description 3 6 Slot for Multi Function Interface The inverter is equipped with a slot for multi function interfaces This slot is designed to connect a simple multi function relay an SMA Power Control Module or a fan retrofit kit The multi function interface can either be retrofitted or installed ex works according to a specific order Multi Function Relay The multifunction relay can activate and deactivate err
13. rid User Manual WB3 5TL 21 BA en 10 13 3 Product Description 3 3 Type Label The type label uniquely identifies the inverter The type label is located on the right hand side of the SMA Solar Technology AG enclosure A WINDY BOY E WB XXXXTL XX T del XXX XXX V W VA risks C IN A A Figure 4 Design of the type label Position Description Explanation A Model Inverter device type B Date of manufacture Inverter manufacture date year month day Additional information Field for additional information e g country specific standard information D Device specific characteristics Serial No Inverter serial number You will require the information on the type label to use the inverter safely and when seeking customer support from the SMA Service line The type label must be permanently attached to the inverter 14 WB3 5TL 2 1 BA en 10 User Manual SMA Solar Technology Symbols on the Type Label 3 Product Description Symbol Description Danger to life due to high voltages Explanation The product operates at high voltages All work on the inverter must be carried out by skilled persons only P Risk of burns from hot surfaces The product can become hot during operation
14. tion which if not avoided will result in death or serious injury WARNING Indicates hazardous situation which if not avoided can result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Indicates a situation which if not avoided could result in property damage Information that is important for a specific topic or goal but is not safety relevant Indicates an essential requirement for achieving a specific goal Desired result x RO p A problem that might occur Nomenclature Complete designation Designation in this document Small wind turbine system Small wind turbine system plant SMA Bluetooth Wireless Technology Bluetooth Windy Boy Inverter product User Manual WB3 5TL 2 1 BA en 10 5 1 Information on this Document SMA Solar Technology AG Abbreviations Abbreviation Designation Explanation AC Alternating Current DC Direct Current EC European Community LED Light Emitting Diode SWTS Small Wind Turbine System VDE Verband der Elektrotechnik Association for Electrical Electronic Elektronik Informationstechnik e V and Information Technologies WB3 5TL 2 1 BA en 10 User Manual 5 Solar Technology AG 2 Safety 2 Safety 2 1 Intended Use The Windy Boy is a transformerless wind energy inverter which converts th

Download Pdf Manuals

image

Related Search

Related Contents

CRT 48-31V-ES - Wacker Neuson  Home Decorators Collection 8885710810 Instructions / Assembly  Data Sheet - Test Equipment Depot  VIZIO P602ui-B3 User's Manual  Page 1 Page 2 ー 目的 この仕様書 (以下、 「本書」 という。 ) は、 第七  HSM Classic 90.2  IWP-2000-68 User`s Manual  Bio-Bac - Prescott SM, Distributeur de produits de papier et de  bactrim  CATALOGUE  