Contents
1. 11 3 IP Address The PP82x needs an IP address to communicate over Ethernet There are two ways to get an IP address either programmed into the unit or using DHCP Most networks use a DHCP server If there is a PC on the network you may be able to find out whether a PC on the same network uses DCHP as follows Go to Control Panel Select Network Connections Right click on Local Area Connection Select Properties e From the list select Internet Protocol TCP IP press Properties If Obtain an IP address automatically is set then DHCP is probably used However there may be an alternative fixed IP address on the Alternative Configuration tab You can find out what IP address is being used by a PC at any time by Go to Control Panel Select Network Connections Right click on Local Area Connection Select Status Select the Support tab The IP address is displayed GARDASOFT 16 When using a fixed IP address you must ensure that you use an IP address that is not being used by any other device on the network It is usual to keep the first three numbers of the IP address the same as other devices and to change only the last number For example if you have a network consisting of a PC IP address 192 168 1 35 and two PP82xs you might assign the addresses 192 168 1 201 and 192 168 1 202 11 3 1 Programmed IP Address and DHCP For DHCP mode the PP82x acquires its IP address subnet mask and gateway ad
2. A Configuration Program is available from www gardasoft com which allows the PP8 to be configured using the commands below 13 3 Command Structure The PP820 can be programmed using string commands These commands can be sent by RS232 for the PP86x or by Ethernet for the PP82x Configuration programs are available at www gardasoft com for both options The commands comprise a code of two letters followed by the parameters several commands can be placed on a single command line by separating them with a semi colon A carriage return character should be sent to terminate the command line The PP820 will send any replies to the commands followed by a gt character to indicate that the command line has been completed GARDASOFT 20 Commands comprise a code of two letters followed by the parameters if any needed for the command Spaces in the commands are ignored 66 99 Numeric parameters are separated by a comma For a parameter which is a time period the default units are microseconds s ms or us can be added to the end of the number to indicate seconds milliseconds or microseconds For currents a ma can be added to indicate amps or milliamps The default is amps For example Note that parameters are in USA UK format so that a half is written 0 5 not 0 5 The command codes and their meaning are described below The upper case commands are shown fol
3. V gt lt voltage across lighting when pulsing V gt lt duty cycle gt lt pulse width in seconds gt lt trigger frequency in Hertz gt When overdriving the voltage across the lighting is more difficult to find out In most cases it is reasonable to use the voltage rating of the light 9 1 2 GARDASOFT Total Heat Output The heat output for the PP820 is given by adding the heat output for all channels as calculated above There are several ways to reduce the heat output from the PP820 Use pulse mode If the output is only on when you need it then you can dramatically reduce the heat output Feed the camera trigger into the PP820 and pulse the lights Turn the light off when not needed If you don t have precise timing of when the camera will trigger you can use Switched mode to switch the output off or on depending on the trigger input or use remote commands to turn the output on and off Reduce the output current if possible Reduce the supply voltage Most PSUs have some adjustment in their output voltage Connect lights in series instead of parallel If you have an array of lights or LEDs in parallel then changing the arrangement to serial will increase the voltage across them but reduce the overall current Use two PP820s and use less channels from each For high power applications this may be the easiest solution If the heat output is no greater than 16W then no heatsinking is required If the heat o
4. here Spannungen k nnen sich Gesundheitsgef hrdend auswirken Ein und Ausg nge haben keine komplette Leiterbahnisolierungen berschl ge die aus Induktion resultieren k nnen m ssen ausserhalb des PP820 abgehalten werden 4 1 4 Generell Die Controller der PP820 Serie sollten nicht in Applikationen eingesetzt werden in welchen ein Fehlverhalten des Ger tes gesundheitliche Sch den verursachen k nnte oder technische Ausr stung zerst ren k nnte GARDASOFT 5 Safety French 5 1 1 PP820 Consignes d utilisation Veuillez lire attentivement ces consignes avant utilisation de la gamme des produits du PP820 En cas de doute n h sitez pas contacter votre revendeur ou GardaSoft Vision 5 1 2 Chaleur Le PP820 peut atteindre une temp rature tr s lev e Il ne doit pas tre plac proximit d une source de chaleur ou de mat riel inflammable ou la port e du personnel risque de br lure Respecter les puissances requises dans le manuel d utilisation Noter que le contr leur peut atteindre 80 C En cas de court circuit la chaleur qui se dissipe l int rieur du bo tier va fortement augmenter ce qui entra nera une augmentation suppl mentaire de temp rature 5 1 3 Electrique L utilisateur doit s assurer que la difference de potentiel des combinaisons ne doit pas exc der la tension de l alimentation ATTENTION Une tension trop lev e pourrait entra ner de graves cons quence
5. output channel All the parameters for each output channel can be set up Press the Submit button to update the PP82x and save the changes to non volatile memory GARDASOFT 13 RS232 and Ethernet Commands 13 1 Communication The PP820 can be configured via the Ethernet connection using UDP or TCP IP Sample C communication source code is available from Gardasoft Vision Communication consists of commands sent by the host controlling PC All output generated by the command is returned in reply UDP or TCP IP packets The last character sent is gt greater than symbol Once this is received the host knows that the command has been completed It is recommended that the host waits for the gt symbol before sending the next command UDP communications are not guaranteed to arrive so the host software must be able to cope with lost messages Using the GT command a host can request that a message is sent to it whenever an error occurs For TCP commands from a host should be sent to destination port 30313 Replies will be to destination port 30312 For UDP commands from a host should be sent from source port 30312 to destination port 30313 Replies will be sent from source port 30313 to destination port 30312 A TCP IP connection will timeout and close if it is idle for more than 10 seconds The host must send regular heartbeat commands e g VR to keep the link open 13 2 Configuration Program
6. source port 30311 destination port 30310 It is formatted as Gardasoft PP82x 000000 111111111111 22222222 8 bit ASCII 44 characters where 000000 the serial number of the unit 111111111111 the MAC address in 6 HEX bytes 22222222 the IP address in 4 HEX bytes For example for PP822 serial number 12345 IP address 192 168 1 103 MAC address 00 0B 75 01 80 99 the packet comprises Gardasoft PP822 012345 000B75018099 C0A80167 GARDASOFT 12 Webpage Configuration PP82x only The PP82x has a small webserver inside so that it can be configured using a standard web browser such as Internet Explorer The IP address of the PP82x must be known it can be searched for or set using the Ethernet configuration program Open a web browser window and type the IP address for example 192 168 1 71 of the PP82x into the URL box at the top The main page of the PP82x webserver should be shown All web pages except the main page can be password protected If the password is unknown it can be reset from the Ethernet configuration program 12 1 Main Page The main page shows general information about the PP82x Links are provided to the configuration pages 12 2 General Setup Page The general setup page allows various parameters to be set up and the webpage password to be set There is also a text box where any command see section 13 can be entered 12 3 Channel Configuration Pages There is one Channel Configuration Page for each
7. 20F 20 Lighting controller 8 channels up to 20A fast pulsing Ethernet RT860F 20 Lighting controller 8 channels up to 20A fast pulsing RS232 PP704 DIN Rail mounting clip for RT range PP Range 2 4 or 8 output channels up to 20A each 2 4 or 8 trigger inputs SafeSense option Front panel RS232 or Ethernet configuration Fast pulsing option Machine Vision Timing Controller CC320 Controller PP703 8 digital inputs 8 digital outputs 1 or 2 wire Encoder input Very flexible operation Ethernet control Front panel configuration DIN Rail mounting clip for CC320
8. D lighting unit as described in Connections Read the section on Operation and set up the PP820 to supply a small continuous current to the LED unit Check that the LED unit illuminates Refer to the Communications section and read how to send RS232 or Ethernet commands Mount the PP820 as described in Mechanical Fixing using the mounting holes In particular read the notes on heatsinking Set up the PP820 for the desired operation and test Visit www gardasoft com for Application Notes on this product GARDASOFT 3 Safety English 3 1 1 PP820 Safety Please read this before using the PP820 family of products If in doubt contact your distributor or Gardasoft Vision 3 1 2 Heat The PP820 can get very hot It should be positioned where personnel cannot accidentally touch it and away from flammable materials Do not exceed the power ratings given in the manual Note that at the maximum ratings the case temperature can reach 80 C If the output load is short circuited then the heat dissipated within the unit will greatly increase resulting in a further rise in temperature 3 1 3 Electrical The user must ensure that the potential difference between any combination of applied signals does not exceed the supply voltage WARNING Higher voltages may cause a danger to personal health The PP820 does not have complete tracking isolation of inputs and outputs Transients caused by inductive loads must be suppr
9. OFT Gardasoft Traffic Strobe Lights The products available at the time of writing include the following Other products are also available See www gardasoft com for details of the current range VTR1 Range Up to 300W per steradian output power Infra red 740nm 850nm 940nm and white options Ethernet RS232 and RS422 options Trigger input and trigger output options 12 degree and 30 degree beam angle options VTR2 Range Up to 3000W per steradian output power Infra red 740nm 850nm 940nm and white options Ethernet RS232 and RS422 options Trigger input and trigger output options 12 degree and 30 degree beam angle options GARDASOFT Gardasoft LED Lighting Controllers RT Range 2 4 or 8 output channels up to 20A each 2 4 or 8 trigger inputs SafePower and SafeSense Front panel RS232 or Ethernet configuration Fast pulsing option RT200 20 Lighting controller 2 channels up to 20A pulsing front panel RT220 20 Lighting controller 2 channels up to 20A pulsing Ethernet RT260 20 Lighting controller 2 channels up to 20A pulsing RS232 RT200F 20 Lighting controller 2 channels up to 20A fast pulsing front panel RT220F 20 Lighting controller 2 channels up to 20A fast pulsing Ethernet RT260F 20 Lighting controller 2 channels up to 20A fast pulsing RS232 RT420 20 Lighting controller 4 channels up to 20A pulsing Ethernet RT420F 20 Lighting controller 4 channels up to 20A fast pulsing Ethernet RT8
10. SZ VISION USER MANUAL 1 PP820 PP821 PP822 PP820C PP821C PP822C PP860 PP861 PP862 PP860C PP861C PP862C LED Lighting Controllers Revision 12 Gardasoft Vision Ltd Trinity Court Swavesey Cambridge CB24 4UQ UK Tel 44 1954 234970 Fax 44 1954 231567 Web www gardasoft com GARDASOFT 1 Disclaimer Except as prohibited by law All hardware software and documentation is provided on an as is basis It is essential that the user ensures that the operation of the product is suitable for their application The user must ensure that incorrect functioning of this equipment cannot cause any dangerous situation or significant financial loss to occur Gardasoft Vision Ltd and Gardasoft Products Ltd will not accept any liability for consequential loss of any kind All trademarks acknowledged Hardware software and documentation are Copyright 2002 2011 Gardasoft Products Ltd Hardware manufactured by Gardasoft Vision Ltd under licence 2 Getting Started Throughout this manual references to the PP820 refer to all products unless otherwise stated PP82x refers to the PP820 PP821 PP822 PP820C PP821C and PP822C PP86x refers to the PP860 PP861 PP862 PP860C PP861C and PP862C Read the sections on Safety and Specifications and check the PP820 fulfils your requirements Gardasoft Vision produces other controllers which are listed on our website Connect the PP820 up to a supply and an LE
11. be saved in non volatile memory so that the PP820 will resume operation after a power cycle GARDASOFT 7 Specifications The supply voltage must be at least 1V above the forward Supply voltage 10V min voltage of the lighting being Vs 48V max driven Ideally set this voltage as low as possible to reduce the total unit power dissipation Quiescent supply current IS SOmA typ Total allowed unit power Pp 16 Watts dissipation in free max air Total unit power dissipation with heatsink Total average 8 12A max output current Operatin p 8 5 c to 40 c temperature range Pp 24 Watts max GARDASOFT 8 Mechanical Fixing The PP820 can be mounted onto a flat surface using the threaded holes in the base see diagram The enclosure of the PP820 is used to dissipate power in the form of heat For this reason the material to which the unit is attached must be suitable preferably metallic with ability to dissipate the produced heat This is particularly important if the power dissipation of the PP820 as defined by Pp the section on Specifications exceeds 10 Watts 2146 x 5 36 s6 b b COTON The PP820 enclosure is a fire enclosure as long as the following conditions are met The unit must be mounted either with the mounting face horizontal or downwards or with the large face of the base horizontal and downwards All downwards facing holes must ha
12. current It is therefore advisable that any power supply is able to limit this inrush current to safe and reasonable values The use of a regulated power supply with 100 short circuit protection is recommended If however a non regulated power supply is used then the maximum ripple voltage of this power supply must not exceed 10 of the actual DC value 10 3 Connectors The RS232 and trigger connections are made using D type connectors The power input and output connectors are arranged as follows GARDASOFT EI ee ee DE Com Li H PF P T VS TRIGGER RS 232 cie cle cle cle E SN 270008 HIH H H H H HJH 7 ol 213 415 elr ADVICE N THE USER MANUAL An CRT N oxygen AR www gardasoft com VS 12 48VITI4A 10 3 1 Power Input The pinout of the power input connector is EE Supply positive The case of the PP820 is not connected to the GND supply connection 10 3 2 Power Outputs Ensure that the output connections do not get shorted together by any metallic object as this can discharge a lot of energy and generate heat in the PP820 Each power output connector has the connections for two output channels The pinout is First channel positive 2o o o e First channel negative 13 Second channel positive a Second channel negative GARDASOFT 14 10 3 3 Serial Connector PP86x only The RS232 connector is a standard 9
13. de The channel is set to continuous mode with the specified output current RSf a Where f output channel 0 to 7 a output current A GARDASOFT 22 For example Set a continuous current of 0 5A on output channel 3 RS3 0 5 13 3 5 Switched Output Mode The channel is set to switched mode with the specified output current RWf a Where f output channel 0 to 7 a output current A For example Set channel 4 to output 1A whenever input 4 is active RW4 1 0 13 3 6 Pulsed Output Mode Set the pulse parameters This command sets a channel to pulsed output Note that output channel 1 can only be triggered by INPUT and output channel 2 can only be triggered by INPUT2 etc The pulse delay can be from about 3us to 1 second The pulse width can be any value from lus to 1 second RTf p d a RTf p d a r Where f output channel 0 to 7 p pulse width microseconds d delay from trigger to pulse microseconds a output current A r retrigger delay microseconds optional For example to set channel 2 to pulsed output at 4A pulse a continuous current of 0 5A on output channel 3 for 1ms after a delay of 500us RT2 1000 500 4 13 3 7 Set Trigger Mode FPO All channels triggered individually FP1 All channels triggered by input 0 FP2 Channels 0 to 3 from trigger 0 4 to 7 from trigger 4 Note that when channels are all being triggered from input 0 that the other triggers should not be pulsed Delays are fro
14. dress from a DHCP server Otherwise the PP820 has a fixed IP address subnet mask and gateway address The PP82x is shipped with DHCP set by default To change the DHCP or fixed IP address setting use the PP82x configuration program downloadable from the PP820 page at www gardasoft com This has a Set Address option which can be used to change the address of a PP82x even if it is wrongly set To do this Connect the PP82x to the network Run the PP820 configuration program Click on Set Address Enter the serial number of the PP82x Select DHCP or Fixed IP Set the fixed IP addresses Press Send Only the PP82x with the specified serial number will be changed The IP address of all the Gardasoft controllers can be found by clicking the Search button in the configuration program 11 4 Communication All the features below are implemented in a demonstration program available from www gardasoft com 11 4 1 Automatic Sensing The PP82x sends out a message on three events e On power up When an IP address is received or renewed by DHCP GARDASOFT When an enquiry message is received On the first two events the message is broadcast On the third it is a reply to a single IP address An enquiry message is a UDP packet from source port 30310 destination port 30311 with the message body GardasoftSearch 8 bit ASCII 13 characters The message output by the PP82x is a UDP packet from
15. essed external to the PP820 When switched off there is still energy stored in the PP820 for about 15 seconds 10 seconds after the power LED goes off the energy has been discharged The PP820 outputs high energy pulses Care must be taken to connect the outputs correctly and protect the output wiring and load from inadvertent short circuits 3 1 4 General The PP820 must not be used in an application where its failure could cause a danger to personal health or damage to other equipment GARDASOFT 4 Safety German 4 11 Sicherheitshinweis PP820 Bitte lesen Sie sich diesen Sicherheitshinweis gr ndlich durch bevor Sie die Produkte der Serie PP820 benutzen Sollten dennoch Zweifel Ihrerseits bestehen z gern Sie nicht sich mit uns in Verbindung zu setzen 4 1 2 Warmeentwicklung Die Ger te k nnen w hrend des Betriebes sehr heiss werden Sie sollten daher dort untergebracht sein wo Personen keine Brandverletzungen erleiden k nnen und wo sich keine entflammbaren Materialen befinden berschreiten Sie nicht die im Manual angegeben H chstspannungen Beachten Sie dass die Temperaturen bei max Spannung bereits 80 C betragen k nnen Wird pro Kanal mit hohen Blitzspannungen und kurzen Blitzzeiten gearbeitet steigen die Temperaturen nochmals an 4 1 3 Elektrischer Betrieb Stellen Sie sicher dass die Spannungsdifferenz zwischen jeder Kombination angelegter Signale nicht die Versorgungsspannung bersteigt ACHTUNG H
16. lowed by lower case letters denoting the numeric argument A parameter value is invalid Command not recognised Numeric value is wrong format Wrong number of parameters Err 5 Warning only A timing parameter was out of range and has been adjusted Any changes made using these commands are not saved permanently until the AW command has been issued GARDASOFT 21 13 3 1 Save the settings to memory AW Once the settings are saved to memory they are then retained when the unit is switched off If this is not done changes to the settings are volatile and if the unit is switched off they revert to those in force when the last AW command was issued 13 32 Report the current settings for the outputs ST Output the status of all channels STf Output the status for one channel f output channel 0 to 7 The status is output in the following format fM1VaDdPpRr For Pulsed Output Mode fM2Va For Constant Mode fM3Va For Switched Mode Where f output channel m is one of 0 Not set up 1 Pulsed output 2 Continuous output Output current amps Pulse width microseconds Delay before pulse microseconds Retrigger delay r em ST8 This command reports the internal trigger mode period TT command and the trigger mode FP command settings Typical output is TT 1 TP 20 00ms FP 0 13 3 3 Report the firmware version VR This command returns the firmware version For example PP820 HWO05 V034 13 3 4 Continuous Output Mo
17. m 4us to 10us longer in FP1 and FP2 modes GARDASOFT 23 This setting can be saved to non volatile memory using the AW command 13 3 8 Internal Trigger Mode This command enables or disables the internal trigger When enabled all outputs are triggered simultaneously using an internal trigger signal This setting can be saved to non volatile memory using the AW command TTO Use external triggers TT1 Use internal trigger defaults to 25Hz TTLp Use internal trigger and set the period Where p period of the triggers in microseconds For example TT1 200MS Set the internal trigger to 200ms 5Hz TT1 100 Set the internal trigger to 100us 10KHZz 13 3 9 Clear Settings Clear all output channel settings All output channel and timer settings are cleared to default to 0 0A continuous This does not clear any Ethernet settings CL Simulate an Input Trigger TRe c which input channel 0 to 7 Simulates a trigger pulse Enable Ethernet Messages GTm m 0 to disable Ethernet messages to enable Ethernet messages When Ethernet messages are enabled any error reports are sent to the most recent UDP or TCP address from which a command has been received Read any error messages GR If Ethernet messages are disabled then the last error number can be read by this command The reply is of the form ErrN where N is the error code for example Err45 Error 45 was the last error If there are no outstanding errors then an emp
18. s sur la sant du personnel Toutes entr es et sorties du PP820 ne sont pas compl tement isol es 5 1 4 Generalite Le PP820 ne doit pas tre utilis dans les conditions mentionn es ci dessus sous peine de cons quences graves sur la sant du personnel ou d endommagement d autre quipement GARDASOFT 6 General Description The PP820 current controller provides repeatable intensity control of LED lighting for machine vision applications It includes the power supply intensity control timing and triggering functions required for machine vision systems LED lighting needs a constant current supply as small variations in voltage can cause large variations in light output Currents can be specified as follows current PP820 PP860 100mA Three modes of operation are provided separately for each channel Continuous In continuous mode the output is a continuous current Strobed In this mode output is pulsed once per trigger One input is used as a trigger The pulse width can range from lus to 300ms in O lus steps The delay can range from 4us to 300ms in O lus steps Switched In switched mode a trigger input can be used to switch the output current on and off The output is only enabled when the input has a voltage on it Triggers occur on the leading edge of the input that is on the transition from logic 0 to logic 1 Output 1 is triggered from INPUT 1 output 2 from INPUT 2 etc Configurations can
19. ty reply is sent followed by the gt character that normally terminates a reply message GARDASOFT 24 Set Clear the Webpage Password EY EY ascl asc2 asc3 asc4 asc5 asc6 This command sets the password required to access the webpages If EY is entered on its own then the password is cleared There are six optional parameters which are ASCII values for a password from one to six letters A value of 65 is A 66 is B etc to 90 is Z 13 3 10 Command Summary es CET EEE CC ET ET RT2 3 4 1 9 Set channel 2 to 3ms pulses delayed by 4ms with an output pulse current of 1 9A GARDASOFT 25 A Error Codes Error codes may be sent by the PP820 by Ethernet or RS232 These are shown as Errnn where nn gives the number of the error The error codes are El One of the parameters to a command has an illegal value E2 Command not recognised E3 Failed to save parameters to non volatile memory E4 The command has the wrong number of parameters ES Warning only A timing parameter was out of range and has been adjusted E18 On power up the stored configuration was invalid E40 When the unit has powered up the non volatile memory was corrupt and has been cleared Set up the unit again All other errors A hardware error has occurred Try power cycling the unit and trying again to see if the fault clears If not make a note of the number and contact your distributor GARDAS
20. utput is between 16W and 24W then the PP820 needs to be bolted to a solid piece of metal to dissipate the heat Above 24W it is necessary to have a large heatsink with fan cooling GARDASOFT 10 Connections 10 1 External Cables To prevent overload of output wiring all power and output cabling must be rated for a continuous load current of 6 3A minimum This does not however apply to the RS232 and Trigger input connections 10 2 Power Supply To avoid a fire hazard from the PP820 or the power supply consider the implications of overheating in the unlikely event of a fault in the PP820 The power dissipation in the PP820 in a fault condition can be up to lt Power supply voltage gt lt max current delivered by Power supply gt Either limit the power supply output current so that not more than 30W can be dissipated in the PP820 or mount the unit in a fire enclosure To limit the power set the power supply output voltages to the minimum value required by the LED light and the PP820 together Choose a PSU that limits its output current by design by setting the current limit on the supply if this feature exists or use fuses Remember to derate the fuse if mounted in an enclosure as the temperature will be higher than ambient The external power supply will need to be able to supply at least the average output current for all channels The PP820 has 30 8mF of reservoir capacitance so on power up there will be a large inrush
21. ve a screw in them If a fire enclosure is used the enclosure should be metal or plastic with a flammability rating of UL94 V1 or better with no holes below or to the sides of the PP820 when mounted Cable entries below the PP820 should be via glands that have a flammability rating as before The PP820 should be at least 10mm from any other part or side of the enclosure The PP820 does not have an IP rating and should be mounted so that moisture and dirt cannot enter the unit GARDASOFT 9 Heat Dissipation The PP820 has a linear circuit to produce the constant current output This means that it generates heat which needs to be dissipated For more information on this and a spreadsheet to calculate the heat output see application note APP941 at www gardasoft com 9 1 1 Heat Output Per Channel For a continuous output current the heat output is given by lt heat output W gt lt output current A gt lt supply voltage V gt lt voltage across lighting V gt where Output current Set by the user Supply voltage Voltage across PSU and PSU Voltage across lighting Voltage across LD and LD This is usually easy to calculate as the voltage across the lighting is usually the voltage rating of the light given in its specification or can be measured using a voltmeter For a pulsed output the heat output is given by lt heat output W gt lt output current A gt lt duty cycle gt lt supply voltage
22. way female D type connected as follows A standard straight through cable can be used to connect the PP86x to a PC serial port The communications port should be set to 115Kbaud no parity 8 data bits and 1 stop bit 2o TX output from PP86x 3 RX input to PP86x s je 10 3 4 Trigger Inputs The trigger input connector is a 9 way D type male The trigger connector pinout is given below i rm Opto Coupled Trigger Input Em Input 4 positiv e Details ee e Input 3 positi Input 2 positive Input 1 positive Input 0 positive Operating Conditions ND connected to PSU GND SV lt Vrric lt 24V Logic 1 Input 7 positive Vrric lt 1V Logic 0 Input 6 positive VE 1 5V typ Input 5 positive 10 3 5 Ethernet Connection PP82x only The RJ45 Ethernet connector requires a straight through cable to connect into a network switch hub or router It runs at 10Mbits per second GARDASOFT 11 Ethernet Setup PP82x only You may need to ask your network administrator for advice about setting up the Ethernet connection Ethernet set up is not affected by cold booting the PP82x 11 1 Connection The Ethernet link uses a 10BaseT connection on a RJ45 connector The PP82x is usually connected to a network switch or hub or router but it is possible to connect the controller directly into the network port on a PC by using a swapover cable 11 2 MAC Address The PP820x MAC address is 0x00 0x0B 0x75 0x01 0xNN OxNN