1. 12 13 ABSICHERUNG una ar 13 14 Blitzlampenanschluss 14 Anzahl Blitzlampen 15 Leistungsverteilung 15 Mechanischer Anschluss der Lampenstecker 15 Pl ugmatiKG u au aa naam a huuu s 15 Zuschaltung der Blitzausg nge 15 Z Beer urma baa tn Sua a 16 Ein und Ausschaltlen 16 Synchronisation 16 17 Blitzleistungsverteilung der Ausgangsbuchsen 17 18 Leistungsregelung 18 Blitzbereitschaft 19 APB Sysiem unse ee 19 Einstelllieht anne 19 20 PUIGIO 722 225 22 asa usyapapapur teneisich 20 Ger teadresse 20 Testelt ass ea an 21 Langsamladung 20 21 Remote Buchse 21 22 Fehlermeldungen 22 8 Wan ng ena m a Sus s Suku 23 Sicherungen austauschen 23 Turnusm ige Uberpr fung 23 R cksendung an Kundendienst 24 9 ENISOTQUNG zelnen Glee acs 24 V0 ZUP6N0katskskav npl ssus a E E 24 11 Kundendienst 25
2. Nicht aus kurzer Distanz unter 5 m in die Augen blitzen da dies zu Augensch den f hren kann Nicht direkt in den Blitzreflektor blicken der Blitz k nnte ver sehentlich ausgel st werden Geschlossene R ume regelm ig l ften um unzul s sige Ozonkonzentrationen die durch die Verwendung starker Blitzger te entstehen k nnen zu vermeiden Bei Arbeiten im Studio die eine hohe Staubentwick lung verursachen sind nicht im Betrieb befindliche Ger te durch einen geeigneten Staubschutz abzu decken HENSEL VISIT International GmbH Bedienungsanleitung Tria S Generatoren 4 Technische Daten Ger teserie Ger tetyp Tria Generator 1500 Speed 1500 S 3000 S 6000 S Nennenergie 1500 J 1500 J 3000 J 6000 J Leitblende 100 ASA t 1 60 2m Abstand Intensity Refl 1 MH 64 4 10 64 5 10 90 5 10 128 5 10 3000 1 MH 6000 Abbrennzeit t 0 5 in Sek 1 EH PRO 3000 6000 1 1500 1 800 1 500 1 400 3 MH 3000 Speed 1 5300 1 2500 1 1700 Ladezeit in Sek 100 1 0 1 7 2 0 4 4 1 32 0 3 0 4 0 5 0 7 Leistungseinstellung 6 f einstellbar in 1 10 f I I feste Leistungsverteilung symmetrisch symmetrisch symmetrisch Asymmetrie Anzahl Blitzausg nge 3 3 3 3 Einstelllampe max 230 V 650 W 650 W 650 W 650 W 115 V 300 W 300 W 300 W 300 W Sicherung Einstelllampe 10 AF 10 AF 10 AF 10 AF Netzanschluss Soe OO i Multivoltage Version 230 V 115 V
3. of and recycled Worn out and broken appliances must be disposed of by electronics recycling 44 HENSEL VISIT International GmbH User manual Tria S Power Packs 10 Accessories There is a wide range of useful accessory available We recommend you e Pile up ring Set 4 pcs Code No 9590521 e Flash Heads series EH PRO and MH e Cable Remote Control RC X Code No 3310 e Radio Flash Trigger System Strobe Wizard Plus Code No 3952 e Spollights e Linear flashlight units F e Reflectors softboxes autolights e Umbrellas Before connecting flash heads their maximum load must be observed 11 Customer service Works customer service with 24 hours express service HENSEL VISIT International GmbH GERMANY service department Robert Bunsen Str 3 D 97076 Wurzburg Phone 49 0 931 27881 0 Fax 49 0 931 27881 50 International service addresses are available at www hensel de HENSEL VISIT International GmbH 45 Declaration of Conformity TRIA S_01 doc Declaration of Conformity for Electromagnetic Compatibility and Safety Manufacturer HENSEL Studiotechnik GmbH amp Co KG Robert Bunsen Str 3 97076 W rzburg Germany Owner of Certification HENSEL Studiotechnik GmbH amp Co KG Robert Bunsen Str 3 97076 W rzburg Germany Test Report of Mai 11 2010 Product TRIA 1500 S TRIA 1500 Speed TRIA 3000 S TRIA 6000 S Description Emission and Interference Resistance Standards EN 61000 6 2 200
4. This enables unplugging and re plugging the flash plugs without danger Only after the plug has been fully inserted the triggering voltage is enabled by micro switch Still plugs should only be unplugged or plugged in when the generator is turned off Lamp switches ON OFF After connecting lamp plugs the corresponding lamp control switches 15 must be turned on for operation This is indicated by the red light of the control LED 7 Operation Switching ON and OFF By pressing switch 3 the generator will be turned on and off respectively HENSEL VISIT International GmbH 37 User manual Tria S Power Packs 4 YNC o LAVE Strobe Wizard Plus 38 Synchronization Flash triggering Synchronization by cable e Via the synchronization socket 4 the generator is connected to the camera using a synchronization cable with 6 3 mm phone jack e You can connect several generators to another by means of the second synchronization socket 4 The synchronization circuit is made up of state of the art semi conductor technology and enables secure triggering of the flash even with older cameras with mechanical contacts Due to the many different electronic circuits in cameras for controlling synchronization we cannot take any liability for possible damage to cameras triggering flashes Please contact the camera manufacturer before using an unusual camera Synchronization by slave The built in slave 18 can
5. sollte je Ger tetyp eine Originalverpack ung aufbewahrt werden 9 Entsorgung ay Das Verpackungsmaterial des Generators ist zu trennen und der Wiederverwertung zuzuf hren Ausgediente und defekte Ger te m ssen dem Elektronikrecycling zuge f hrt werden uw 10 Zubeh r Aus unserem reichhaltigen Zubeh rprogramm empfehlen wir f r den Tria Generator e Stapelring Set 4 St ck Art Nr 9590521 e Flash Heads Serie EH PRO und MH e Kabelfernbedienung RC X Art Nr 3310 e Funkfernausl sung Strobe Wizard Plus Art Nr 3952 e Spotlights e Stabblitze Ea e Reflektoren Softboxen Autolights e Schirme Vor dem Anschluss von Flash Heads ist deren Maximal belastung zu beachten 24 HENSEL VISIT International GmbH Bedienungsanleitung Tria S Generatoren 11 Kundendienst Werkskundendienst mit 24 Stunden Express Service HENSEL VISIT International GmbH GERMANY Serviceabteilung Robert Bunsen Str 3 D 97076 W rzburg Tel 0931 27 88 1 0 Fax 0931 27 88 1 50 E Mail info hensel de Internet www hensel de Autorisierte Kundendienste im Inland Andreas Jakob Blitzservice Chapeaurougeweg 13 Tel D 20535 Hamburg Fax J rgen Skaletz Elektronik Service Im langen M hlentfeld 7 Tel D 31303 Burgdorf Fax Arne Pohl Elektronik Service Sandbergstra e 29 Tel D 51147 K ln Wahn Fax Kersten Heilmann Reparaturservice Friedhofstr 66 Tel D 85716 Unterschlei heim Fax
6. EG Konformit tserkl rung 26 HENSEL VISIT International GmbH Bestimmungsge maBer Gebrauch Nicht bestimmungs gemaBer Gebrauch Bedienungsanleitung Tria S Generatoren 3 Allgemeine Sicherheitsbestimmungen Generatoren speichern Energie in Kondensatoren durch Anlegen hoher Spannungen Dadurch sind Gefahren quellen gegeben die sorgf ltig auszuschlie en sind Neben den allgemeinen Regeln im Umgang mit elektri schen Ger ten sind deshalb Vorsichtsma nahmen zu treffen die nachfolgend beschrieben sind Lesen und befolgen Sie deshalb die Sicherheitshinweise siehe auch Kapitel Inbetriebnahme und die Bedienungsanleitung vor Inbetriebnahme des Ger tes Der vorliegende Generator ist f r den Studioeinsatz des professionellen Fotografen bestimmt Die Aufgabe ist das Bereitstellen der elektrischen Energie f r festgelegte Typen von Blitzleuchten Das Ger t darf zu keinem anderen Zweck benutzt wer den als oben beschrieben insbesondere nicht f r andere elektrische Anwendungen Der Kontakt mit der Kondensatorspannung ist le bensgef hrlich deshalb d rfen das Offnen des Ge neratorgeh uses und Reparaturen nur von einem autorisierten Kundendienst vorgenommen werden e Blitzr hren d rfen nur von autorisiertem geschultem Personal gewechselt werden Das Wechseln der Blitzr hre und der Einstelllampe darf nur bei ausge schaltetem vom Stromnetz getrenntem und entlade nem Ger t vorgen
7. Gewicht ko 8 3 8 0 9 3 17 1 L 34 5 cm 34 5 cm 34 5 cm 34 5 cm MaBe mit Griff B 19 5 cm 19 5 cm 19 5 cm 19 5 cm H 28 5 cm 28 5 cm 28 5 cm 43 8 cm Art Nr 230 V Version 3500 3515 3530 3560 Multivoltage 3600 3615 3630 3660 Technische Anderungen vorbehalten Messungen bei 230 V HENSEL VISIT International GmbH 9 Bedienungsanleitung Tria S Generatoren 10 5 14 14a 14b 14c 15 16 18 19 20 21 22 bersicht ber die Bedienelemente 10 AF Schmelzsicherung 10 AF f r Einstelllampe 230 V 50 60 Hz Netzanschlussbuchse ON OFF Hauptschalter EIN AUS SYNC Synchronbuchsen 2 St ck BIAS 1f und 2f FC Flash Check LAMP Einstelllicht EIN AUS AUDIO Akustische Blitzbereitschaft EIN AUS FREE PROP Einstelllicht FREE oder PROP Betrieb SLAVE Fotozelle EIN AUS Ready Indikator Blitzbereitschaftsanzeige SLOW Langsamladung TEST Blitzhandausl sung Blitzlampenbuchsen 1 2 und 3 Buchse 1 50 Buchse nur bei Tria 6000 S Buchse 2 50 Buchse nur bei Tria 6000 S Buchse 3 100 Buchse nur bei Tria 6000 S Lampenkontrollschalter REMOTE 1 2 Anschluss Kabelfernbedienung RC X ID Identifikationsnummer f r Generator Fotozelle LED Anzeige Einstelllicht LED Anzeige Blitzenergie Regler Einstelllicht Regler Blitzenergie HENSEL VISIT International GmbH Bedienungsanleitung Tria S Generatoren 6 Inbetriebnahme Sicherheitshinweise beim Umgang mit angesc
8. Power Packs FREE PROP When switch 9 is set to FREE position the modeling lamp output can be adjusted using modeling lamp control switch 21 independently from the chosen flash power output To have proportionality between modeling lamp and flash switch 9 has to be set to PROP In that case the setting of modeling lamp control 21 is not longer valid The mode of operation is indicated by the control LED By turning switch 21 the modeling lamp output can be set in 1 10 f stop increments over a range of 6 f stops The modeling lamp output will be shown digitally on the two digits 7 segment display 19 BIAS In case of operation with several flash light units it can be useful to adjust the output of the pilot light To reduce the modeling light output by one and two f stops respectively set the BIAS switch 5 to 1f respectively 2f The control indicator lights up Flash Check If this mode is switched on using switch 6 LED indicator lights up then the modeling lamp is turned off after a flash and is turned on after recharging to the adjusted power level This shows correct charge as well as readiness to flash The flash check mode guarantees that the flash heads have triggered when more than one flash unit is used Audio Readiness to flash after charging is signalled with a tone This tone can be turned on control LED lights up or off using the switch 8 AUDIO The pitch is related to the ID number Therefore
9. agency Assembly When mounting to a ceiling system or a pantograph suspended flash heads have to be doubly secured from falling down This is done by tightening the safety screw on the HENSEL U bracket or the wrench screw on the HENSEL tilting head Due to the existing safety regulations it is however necessary to use a safety rope Code No 769 for further security The safety rope has to be led through the handle of the flash head and then secured by looping through the bracket on the pantograph or the eyelet on the carriage HENSEL VISIT International GmbH 33 User manual Tria S Power Packs 2 34 Development of heat Due to the modeling and flash light each generator and flash head emits heat This can heat the parts of the unit up to a dangerous level Therefore make sure that ge nerators and lamp heads are located far enough from inflammable props to avoid inflaming them Take care of sufficient air supply and make sure that the ventilation slots of generators and flash heads are kept free Do not operate generators and flash heads unattended Due to the danger of overheating the modeling light should never be operated at full power for more than 20 minutes Then adequate cooling should be provided for The modeling light should never be used for lighting up the studio but only as assistance when focusing or determining the light guiding and shadow details of the flash Acclimatizing When moving generator
10. 1 400 3 MH 3000 Speed 1 5300 1 2500 1 1700 Recycle in to 100 1 0 1 7 2 0 4 4 sec to 1 32 output 0 3 0 4 0 5 0 7 Power adjustment 6 f adjustable in 1 10 f Power distribution symmetrical symmetrical symmetrical ued asymmetry No of flash sockets 3 3 3 3 Modeling lamp max 230 V 650 W 650 W 650 W 650 W 115 V 300 W 300 W 300 W 300 W Fuse modeling lamp 10 AF 10 AF 10 AF 10 AF Mains voltage 230 V 50 60 Hz Multivoltage version 230 V 115 V Weight kg 8 3 8 0 9 3 17 1 Measurements with L 34 5 cm 34 5 cm 34 5 cm 34 5 cm handle B 19 5 cm 19 5 cm 19 5 cm 19 5 cm H 28 5 cm 28 5 cm 28 5 cm 43 8 cm Code 230 V Version 3500 3515 3530 3560 Multivoltage 3600 3615 3630 3660 Technical changes reserved Values attained at 230 V 50 Hz voltage HENSEL VISIT International GmbH 31 User manual Tria S Power Packs 32 5 Overview of controls 1 2 14 14a 14b 14c 15 16 18 19 20 21 22 10 AF Fuse 10 AF for modeling lamp 230 V 50 60 Hz Mains connector ON Main switch ON OFF SYNC Synchronization socket BIAS FC Flash Check LAMP Modeling lamp ON OFF AUDIO Acoustical signal for flash readiness ON OFF FREE PROP Modeling lamp options FREE or PROP SLAVE Slave ON OFF Ready indicator indicator for flash readiness SLOW Slow charge TEST Manual flash release Flash sockets 1 2 and 3 Socket 1 50 Socket
11. 5 EN 61000 6 3 2007 This declaration of conformity is made by the above mentioned manufacturer according to article 10 paragraph 1 of the governing EU directives 2004 108 EC referring to electromagnetic compatibility and safety for bringing the statutory instruments of the Member States into lines with each other This declaration does not make any statement according to requirements of other provisions concerning the electromagnetic compatibility and safety Description Low Voltage Directive Standards EN 60065 2002 A1 2006 Cor 2007 A11 2008 EN 60598 1 2008 A11 2009 EN 60598 2 9 1989 A1 1994 This declaration of conformity is made by the above mentioned manufacturer according to article 10 paragraph 1 of the Governing EU directives 2006 95 EC referring to electrical items for usage within specified voltage limits This declaration of conformity is the result of testing samples of the products submitted in accordance with the provisions of the relevant specific standards Date Mai 11 2010 Mantfactyr r E Stumpf Ma aging Director HENSEL Studiotechnik HENSEL WWW HENSEL DE
12. EL VISIT bestellt werden Flash Heads mit Halogenlampen die nicht ber ein K hl gebl se verf gen d rfen nicht verwendet werden Bei schneller Blitzfolge w rden Defekte an der Blitzr hre und damit auch am Generator entstehen Fremdhersteller Obwohl hnliche Lampenbuchsen und stecker auch von anderen Fabrikaten benutzt werden d rfen Lampen und Blitzk pfe dieser Hersteller nicht an den Tria Generator angeschlossen werden Bitte kontaktieren Sie den HENSEL Kundendienst bez glich Adaptionsm glichkei ten HENSEL VISIT International GmbH Bedienungsanleitung Tria S Generatoren Anzahl Blitzlampen Es d rfen maximal 3 Blitzk pfe gleichzeitig angeschlos sen werden Die maximale Belastbarkeit des Blitzkopfes darf nicht berschritten werden Leistungsverteilung Die Leistungsabgabe erfolgt symmetrisch ber die 3 Blitzlampenbuchsen 14 Mechanischer Anschluss der Lampenstecker e Vor Anschluss der Lampenstecker Lampenkontroll schalter 15 und den Generator mit Hauptschalter 3 ausschalten e Nur einwandfreie Stecker und Buchsen verwenden Der Lampenstecker wird durch eine mechanische Ver riegelung arretiert Hierzu den Stecker leicht nach vorne geneigt in die Blitzbuchse 14 einstecken und an schlieBend hinten beim Kabelausgang fest in die Ver riegelung dr cken Zum L sen des Steckers die Verriegelungslasche zur ckdr cken und Stecker hinten am Kabelausgang nach oben abziehen Plugmatik Die Blitzbuchsen 14 s
13. FC AUDIO 7 LAMP 40 Flash power control The flash power can be set in 1 10 f stop increments using power control 22 This covers a range of 6 f stops 111 to 1 32 The cable remote control unit RC X accessory Code No 3310 only allows for flash power adjustment in 2 10 f stop increments The flash output will be shown on the two digits 7 segment display 20 see table below Table Flash power output LED Flash power output J Tria power pack display 1500S 3000S 6000S 1500 Speed 10 1500 3000 6000 1500 9 0 750 1500 3000 750 8 0 375 750 1500 375 7 0 187 375 750 187 6 0 93 187 375 93 5 0 46 93 187 46 Flash readiness Flash readiness of the generator is shown by e READY control lamp 11 turned on green light e Modeling lamp turned on when Flash Check mode is activated switch 6 e Acoustical signal when AUDIO 8 is switched on APD system In case of reducing the flash power the stored energy will be discharged by the APD system Automatic Power Drop No flash will be triggered After switching off generators will be discharged automatically Modeling lamp The modeling light will be turned on respectively off using switch 7 Turning on of the modeling lamp is only effective when the connected flash head and its modeling lamp are switched on HENSEL VISIT International GmbH 9 REE 9 ROP 21 5 IAS 710 8 UDIO ID 13 TEST User manual Tria S
14. Firma HENSEL hat sich alle M he gegeben unter Einbeziehung und Beachtung aller g ltigen Vorschriften ein sicheres und qualitativ hochwertiges Ger t zu fertigen Strenge Qualit tskontrollen stellen auch bei Gro serien unseren Qualit tsma stab sicher Bitte tun Sie das Ihre hinzu und behandeln Sie die Ger te mit der notwendigen Sorgfalt Sollten Sie zur Nutzung Fragen haben stehen wir Ihnen jederzeit gerne zur Verf gung Wir w nschen Ihnen viel Erfolg und gut Licht HENSEL VISIT International GmbH Bedienungsanleitung Stand 03 2011 Technische nderungen und Druckfehler vorbehalten Die angegebenen Werte sind Richtwerte und im recht lichen Sinne nicht als zugesicherte Eigenschaften zu verstehen Die Werte k nnen durch Bauelementetole ranzen schwanken HENSEL VISIT International GmbH 5 Bedienungsanleitung Tria S Generatoren 2 Inhaltsverzeichnis 1 SEBUIMIG THONG sabab a a 5 2 Inhaltsverzeichnis 6 3 Allgemeine Sicherheitsbestimmungen 7 8 4 Technische Daten 9 5 bersicht der Bedienelemente 10 6 Inbetriebnahme 11 Sicherheitshinweise 11 12 Akklimatisierung 12 Aufstellung ae 12 Netzanschluss
15. IT International GmbH 13 TEST 16 REMOTE 1 19 20 EE EE Bedienungsanleitung Tria S Generatoren Bei der Erstaufladung schaltet sich der Generator f r 10 Sek automatisch auf Langsamladung um Das hat den Vorteil dass sich nach l ngerer Nichtbenutzung die Blitz kondensatoren besser formieren und so eine etwas schwach ausgelegte Netzsicherung nicht sofort ausl st Testblitz Durch Bet tigung des Schalters 13 k nnen Probeblitze ausgel st werden Remote Buchse Remote 1 Buchse Der Tria Generator kann in seinen wesentlichen Funk tionen auch mit der Kabelfernbedienung RC X Art Nr 3310 gesteuert werden Die Kabelfernbedienung wird mit dem mitgelieferten Kabel an die REMOTE 1 Buchse 16 des Generators angeschlossen Folgende Funktionen sind verf gbar e STBY Mit dieser Taste wird der Generator in den Stand by Modus geschaltet Die LED Anzeigen am Generator f r Einstelllicht 19 und Blitzenergie 20 zeigen dann EE EE an e PILOT Mit diesem Schalter wird das Einstelllicht f r PROP Betrieb ein siehe S 16 oder ausgeschaltet Die Hellig keit des Einstelllichtes ist dann proportional zu der mit dem Blitzenergieregler eingestellten Blitzleistung Blitzenergieregler Uber diesen Regler wird in 2 10 f Stufen die gew nschte Blitzenergie gew hlt Zur Einstellung steht ein Bereich von 6 Blendenwerten zur Verf gung READY Durch Aufleuchten wird Blitzbereitschaft signalisiert e TES
16. Kundendienste im Ausland finden Sie auf www hensel de HENSEL VISIT International GmbH 040 21 98 47 13 040 21 98 47 14 0511 7997 22 0511 79 94 84 02203 96 27 54 02203 96 27 55 089 310 14 28 089 310 94 92 25 Konformitaetserklaerung TRIA S doc EG Konformitatserklarung ber die elektromagnetische Vertraglichkeit und elektrische Sicherheit Hersteller HENSEL Studiotechnik GmbH amp Co KG Robert Bunsen Str 3 97076 W rzburg Germany Inhaber der HENSEL Studiotechnik GmbH amp Co KG Bescheinigung Robert Bunsen Str 3 97076 W rzburg Germany Pr fbericht vom 11 5 2010 Objektbezeichnung TRIA 1500 S TRIA 1500 Speed TRIA 3000 S TRIA 6000 S Pr fbeschreibung Emission und St rfestigkeit Pr fstandards EN 61000 6 2 2005 EN 61000 6 3 2007 Diese Konformit tserkl rung wird gem Artikel 10 Abs 1 der Richtlinie des Rates zur Angleichung der Rechtsvorschriften der Mitgliedsstaaten ber die elektromagnetische Vertr glichkeit 2004 108 EC vom oben genannten Hersteller abgegeben Die Erkl rung macht keine Aussagen in Bezug auf die Schutzanforderungen zur elektromagnetischen Vertr glichkeit nach anderen Rechtsvorschriften die der Umsetzung anderer Richtlinien der Europ ischen Union als der EMV Richtlinie dienen Pr fbeschreibung Niederspannungsrichtlinie Pr fstandards EN 60065 2002 A1 2006 Cor 2007 A11 2008 EN 60598 1 2008 A11 2009 EN 60598 2 9 1989 A1 1994 Diese Konformit tserkl rung wird g
17. T Durch Bet tigung der Taste werden Blitze von Hand ausgel st HENSEL VISIT International GmbH 21 Bedienungsanleitung Tria S Generatoren 16 REMOTE 2 3 N OFF 22 e SYNC Au erdem ist eine Synchronbuchse vorhanden Remote 2 Buchse Die Remote 2 Buchse 16 dient dem Durchschleifen mehrerer Generatoren und zum Anschluss an einen Computer Diese Funktionen sind zur Zeit noch nicht verf gbar Fehlermeldungen Er 01 Er 07 Diese Fehlermeldungen erscheinen wenn ein oder mehrere Heads nicht geblitzt haben Durch Bet tigung des entsprechenden Lampenkontrollschalters 15 wird die Fehlermeldung wieder zur ckgesetzt Fehlermeldung Nicht geblitzt Er 01 Head 1 Er 02 Head 2 Er 03 Head 3 Er 04 Head 1 und 2 Er 05 Head 1 und 3 Er 06 Head 2 und 3 Er 07 Head 1 2 und 3 Er 21 Er 34 Fehlermeldungen aufgrund von Uberhitzung Nach Ab k hlung setzen sich diese Meldungen von selbst zur ck Er 40 Er 43 Fehlermeldungen bez glich Ladung bzw sonstiger Fehler Um das Ger t wieder zur ckzusetzen muss es am Hauptschalter 3 ausgeschaltet werden Bei mehrma ligem Auftreten dieser Fehlermeldungen sollte umgehend der Service zu Rate gezogen werden HENSEL VISIT International GmbH 1 10 AF Bedienungsanleitung Tria S Generatoren Wartung Der Tria Generator bedarf wenig VVartung durch den Benutzer Um die elektrische Sicherheit zu gew hr leisten muss das Gerat regelmaBig auBerlich v
18. TRIA 1500 Speed 1500 S 3000 S 6000 S Generator Power Pack BEDIENUNGSANLEITUNG USER MANUAL WWW HENSEL DE HENSEL performing light CC 02 l sSIo4uop Bupdus pag 81 Ll gl Sl opl UABE IMPO OIAR Jan apl WO HUN UDAN Dr Duun yore wm D Yl A DER I DIG El CL IL 0L 6 8 L 9 S r r 1 S0009 SOOOE S00S1 D dS 0091 IOIV I3N392 VIL Bedienungsanleitung Tria S Generatoren HENSEL performing light HENSEL VISIT International GmbH Robert Bunsen Str 3 D 97076 W rzburg Lengfeld GERMANY Tel phone 49 0 931 27881 0 Fax 49 0 931 27881 50 E Mail info hensel de Internet http www hensel de HENSEL VISIT International GmbH 3 Bedienungsanleitung Tria S Generatoren Bedienungsanleitung Tria S Generatoren Stand 03 2011 Seite 5 User manual Tria S Power Packs Date of revision 2011 03 page 28 4 HENSEL VISIT International GmbH Bedienungsanleitung Tria S Generatoren 1 Einleitung Liebe Fotografin lieber Fotograf mit dem Kauf einer HENSEL Blitzanlage haben Sie eine hochwertige und leistungsf hige Ausstattung erworben Damit Sie viele Jahre erfolgreich und produktiv mit die sem Ger t arbeiten k nnen m chten wir Ihnen nach folgend einige Hinweise zum Gebrauch geben Nur durch die notwendige Beachtung unserer Informationen sichern Sie sich Garantieleistungen vermeiden Sie Sch den und verl ngern die Nutzungsdauer des Ger tes Die
19. Tria 6000 S only Socket 2 50 Socket Tria 6000 S only Socket 3 100 Socket Tria 6000 5 only Lamp control switches REMOTE 1 2 Cable remote control RC X connection ID No of identification for the generator Slave LED display of modeling lamp LED display of flash output Modeling lamp control Flash output control HENSEL VISIT International GmbH User manual Tria S Power Packs 6 Starting up Safety hints for operation with connected flash heads To avoid damage to the flash tube mount reflectors and lightformers softboxes etc before use and turning the unit on Do not move generators and lamp heads around while they are operating Turn the appliance off for each change of reflectors or to move the unit to another location Caution reflectors speedrings and other accessories heat up during longer operation To avoid injuries handle with isolating cloth or wait until parts have cooled down A damaged flash tube is extremely dangerous be cause the electrically charged electrodes are ex posed and could be touched In case of a damaged flash tube the flash head has to be unpluqqed from the generator immediately and sent to an authorized HENSEL service department Do not only turn the flash head off because the capacitors inside the generator may still be charged and dangerous high voltage can still be present at the damaged tlash tube electrodes For replacement of flash tubes please consult your local HENSEL
20. al photographers Its task is to provide electrical energy for certain fixed types of HENSEL flash lamps The appliance must not be used for any other purpose than that described above especially not for other electrical appliances Contact with the capacitor voltage is perilous and therefore opening of the case of Tria generator and repairs must only be made by authorized customer service e Flash tubes must only be exchanged by authorized trained personnel Exchange of flash tube and modeling lamp must only be performed with the appliance turned off unplugged from the mains and discharged e Generators must only be used on supply lines mains with working protective conductor earth line e Only lamp connectors with immaculate contacts must be used burned or corroded contacts may cause burstings in the area of connectors and lamp sockets e Do not route cables across the studio floor if possible so that damage is excluded If routing across the studio floor cannot be omitted then it must be ensured that vehicles ladders etc do not damage cables Damaged cables and cases must be replaced immediately by customer service HENSEL VISIT International GmbH 29 User manual Tria S Power Packs 30 Ventilation slots of generators must be kept free during operation and sufficient air supply must be ensured Do not stick any objects into ventilation slots lamp sockets or synchronization sockets Do not de posit any objec
21. e durch Feuchtigkeitsnieders chlag vermieden Aufstellung Tria Generatoren k nnen stehend und liegend Stapel ring Set 4 St ck Art Nr 9590521 betrieben werden Netzanschluss 230 V Version Vor Anschluss des Generators an das Stromnetz muss sichergestellt sein dass die Netzspannung mit den Angaben auf dem Typenschild des Generators berein stimmt Das Typenschild befindet sich am Geh usebo den HENSEL VISIT International GmbH 1 10 AF Bedienungsanleitung Tria S Generatoren Multivoltage Version Der Generator passt sich automatisch der Netzspannung an Blitzgeneratoren d rfen nur an geerdete Stromnetze angeschlossen werden Das mitgelieferte Netzkabel wird mit der Netzanschluss buchse 2 des Generators verbunden und anschlieBend an das Stromnetz angeschlossen Absicherung Steckdosen geb udeseitig Ue 230 V Ue 115 V Langsamladung 10 A 16 A Schnellladung 16 A 20 A Lampensicherung Die Schmelzsicherung 1 ist eine bergeordnete Lampen sicherung Es ist unbedingt darauf zu achten dass ausschlieBlich 10 A Sicherungen mit Ansprechverhalten flink eingesetzt werden 10 AF Absicherung der Halogenlampe im angeschlossenen Blitzkopf Die Halogenlampe im angeschlossenen Blitzlampenkopf ist durch eine 5 x 20 mm Schmelzsicherung mit der Ausl secharakteristik flink f abgesichert Achtung Einstelllampe im Head f r die jeweilige Netz spannung einsetzen und zu
22. elle Buchsenbelegung Tria 6000 S Buchse 1 50 Buchse 2 50 i 3000J _ _ _ mm 3000 J 6000 J 1500 J 1500 J 3000 J 3000 J 3000J 3000 J Die feste asymmetrische Leistungsverteilung beim Tria 6000 S erm glicht auch den Anschluss von 3000er Blitz k pfen bei Verwendung der Buchsen 1 und 2 gem Tabelle Leistungsregelung Mit dem Blitzenergie Regler 22 l sst sich die gew nschte Blitzenergie in 1 10 Stufen einstellen Damit wird ein Leistungsbereich von 6 Blendenwerten abgedeckt Wird die Leistungseinstellung ber die Kabelfernbedie nung RC X Zubeh r Art Nr 3310 vorgenommen kann die Blitzenergie ber den genannten Blendenbereich nur in 2 10 Stufen eingestellt werden Am LED Display 20 2 stellige 7 Segmentanzeige wer den die eingestellten Leistungswerte in folgender Form angezeigt Leistungsabgabe J Tria Generator LED 1500 Anzeige 1500S 3000S 6000 S Speed 10 1500 3000 6000 1500 9 0 750 1500 3000 750 8 0 375 750 1500 375 7 0 187 375 750 187 6 0 93 187 375 93 5 0 46 93 187 46 HENSEL VISIT International GmbH READY FC AUDIO 7 LAMP 9 REE 9 ROP 21 Bedienungsanleitung Tria S Generatoren Blitzbereitschaft Die Blitzbereitschaft wird signalisiert durch 1 Aufleuchten der gr nen READY Kontrolllampe 11 2 Wiederaufleuchten des Einstelllichtes wenn F
23. em Artikel 10 Abs 1 der Richtlinie des Rates zur Angleichung der Rechtsvorschriften der Mitgliedsstaaten betreffend elektrischer Betriebsmittel zur Verwendung innerhalb bestimmter Spannungsgrenzen 2006 95 EG vom oben genannten Hersteller abgegeben Diese Erkl rungen beziehen sich auf das oben beschriebene Produkt Datum der Konformit tserkl rung 11 5 2010 Erngt Stumpf HENSEL Studiotechnik GmbH amp Co KG User manual Tria S Power Packs 1 Introduction Dear photographer in buying a HENSEL flash system you have purchased powerful equipment of high quality So that you are able to work successfully and productively with this system for many years we are giving you some advice on the use of this high tech product Only by observance of the information given you secure your warranty prevent damage and prolong the life of the equipment HENSEL has taken great care to manufacture a secure and high quality flash system under inclusion and obser vance of all current regulations Strict quality controls secure our quality requirements even in mass production Please take your part in this and treat the equipment with due care your reward will consist of excellent pictures If you should have any questions on the use then feel free to ask us at any time We wish you success and good light HENSEL VISIT International GmbH User manual date of revision 2011 03 Technical data are subject to change No guaran
24. from time to time Before cleaning separate the unit from the mains outlet Under no circumstances is any part of the equipment to be opened The equipment is not user serviceable and there is dangerous high voltage In the event of difficulty notify your dealer HENSEL VISIT International GmbH 43 User manual Tria S Power Packs Replacement of fuses In case of a broken fuse 1 for modeling lamp replace fuse only when the unit is switched off and separated from the mains outlet Attention Never repair or bridge fuses Only use the following types of fuses according to IEC 127 2 1 and EN 60127 2 1 sand filled respectively Fuse for Tria generator 10 AF quick Fuses for connected flash heads Ue 230 V Ue 115 V 300 W halogen lamp 2 A quick 4 A quick 600 W halogen lamp 4Aquick Spare fuses for the power pack Spare fuses are integrated in the grip rod of the bracket Regular check National safety regulations require regular inspection and maintenance of electrical systems and appliances Generators and accessories must be checked regularly for safe operation Yearly inspection of the appliances serves the safety of the user and protects your invest ment in the system Return to customer service To achieve a maximum protection of the unit sending it in for service the original packaging should be kept 9 Disposal Packaging of the generator must be separately disposed
25. geordneten Sicherungswert beachten Folgende Sicherungswerte sind zul ssig Ue 230 V Ue 115 V 300 W Halogenlampe 2 A flink 4 A flink 600 W Halogenlampe 4 A flink HENSEL VISIT International GmbH 13 Bedienungsanleitung Tria S Generatoren 14 Reservesicherungen f r den Generator sind im Griffrohr des Trageb gels integriert Blitzlampenanschluss Achtung Vor Anschluss eines Blitzkopfes an den Tria Generator berpr fen ob der Head f r die jeweilige Netz spannung 115V 230V Bi Voltage geeignet ist F r den Anschluss an den Tria Generator sind speziell die Heads der EH PRO Linie entwickelt worden Die Typenbezeichnungen von Blitzkopf und Generator sind aufeinander abgestimmt Es k nnen aber auch Blitzk pfe der MH Serie verwendet werden siehe Tabelle unten Generator Anzuschlie ende Blitzk pfe Tria EH PRO Linie MH Linie 1500 Speed 3000 6000 3000 6000 1500 S 3000 6000 3000 6000 3000 S 3000 6000 3000 6000 6000 S 3000 6000 3000 6000 Die zul ssige Belastbarkeit wird mit einer Blitzkopfer kennung im Stecker berwacht Wenn ein unzul ssiger Kopf angeschlossen wird wird dieser durch die Co dierung erkannt und entweder gegen Abblitzen gesperrt oder in seiner Leistung reduziert Es d rfen nur Verl ng erungskabel verwendet werden die die entsprechende Blitzkopfcodierung beinhalten Diese m ssen mit genauer Spezifikation bei der Fa HENS
26. h readiness nanai e an aia aiaeei iN 39 TAN ig BGs 2 29 4 eee ee u has e a er ne 39 Modeling lamp 40 41 Audio s Satanasta one Sanne aR Rene ea ee 41 Identification number 41 Te stiflashi een 41 Slow charge ans eee ena os eee 42 Remote socket 42 Trouble shooting 43 8 Maintenance u o u uuu u u ua las skansa pla 43 Replacement of fuses 44 Regular check 44 Return to customer service 44 9x Disposal Ara ee een 44 TO SACCOSSOMOS un ee nee 45 T1 Customer servied snm j lbvu s a um 45 Certificate of Conformity 46 HENSEL VISIT International GmbH Proper use Improper use User manual Tria S Power Packs 3 General safety regulations Power packs store electrical energy in capacitors by applying high voltages These form a source of danger which must be carefully excluded Besides general rules on handling electrical appliances the following safety measures must be observed There fore read_and comply the safety hints also see the paragraph Starting up within the user manual before turning the appliance on The present generator is meant for studio use of pro fession
27. hlossenen Blitzk pfen Wegen m glicher Besch digung der Blitzr hre beim Han tieren ist es unbedingt erforderlich vor Einschalten des Blitzkopfes den entsprechenden Lichtformervorsatz Re flektor Softbox o zu montieren und das Ger t an seinen endg ltigen Einsatzort aufzustellen Bei jedem Wechsel des Einsatzortes des Blitzkopfes oder des Lichtformers m ssen Generator und Blitzkopf ausge schaltet werden Achtung Nach l ngerem Betrieb sind Lichtformer spe ziell Reflektoren sehr hei Um Verbrennungen zu ver meiden ist mit einem W rmeschutz zu hantieren bzw die Abk hlphase abzuwarten Eine besch digte Blitzr hre bedeutet Lebensgefahr da die hochspannungsf hrenden Elektroden ber hrt werden k nnen Der Blitzkopf ist unverz glich vom Generator zu trennen und einem autorisierten HENSEL Kundendienst zu bergeben Wird der Blitz kopf nicht vom Generator getrennt sondern dieser lediglich ausgeschaltet k nnen die Kondensatoren noch geladen sein so dass ein Ber hren der Blitz r hrenelektroden des Blitzkopfes lebensgef hrlich ist Montage Bei Montage an Deckenschienen oder Scheren muss der Blitzkopf gegen Herunterfallen doppelt gesichert werden Dies geschieht entweder durch die Sicherungsschraube am HENSEL Neiger oder U B gel Es ist jedoch wegen geltender Sicherheitsvorschriften eine Zweitsicherung durch ein Stahlseil notwendig Dieses kann von der Firma HENSEL VISIT unter der Art Nr 769 bezogen werde
28. ind mit dem HENSEL Sicherheits system Plugmatik ausgestattet Dies erm glicht ein gefahrloses Umstecken des Blitzsteckers Erst nachdem der Stecker ganz eingerastet ist wird ber den Mikro schalter die ZUndspannung zugeschaltet Trotzdem sollte ein Umstecken des Blitzsteckers nur bei ausgeschaltetem Generator erfolgen Zuschaltung der Blitzausg nge Durch Bet tigung des jeweiligen Lampenkontrollschalters 15 werden die entsprechenden Blitzausg nge zugeschal tet Die zugeschalteten Blitzausg nge werden zus tzlich durch das Aufleuchten der Kontroll LED angezeigt HENSEL VISIT International GmbH 15 Bedienungsanleitung Tria S Generatoren 3 N OFF 4 SYNC 18 Fotozelle 10 SLAVE 16 7 Betrieb Ein und Ausschalten Durch Dr cken von Taster 3 wird der Generator ein bzw ausgeschaltet Synchronisation Blitzausl sung Synchronisation ber Kabel e Der Generator wird mit Hilfe eines Synchronkabels mit 6 3 mm Klinkenstecker ber die Synchronbuchse 4 an die Kamera angeschlossen e Die 2 Synchronbuchse 4 ermoglicht es mehrere Ge neratoren untereinander zur Synchronisation zu verbin den Die Synchronschaltung ist auf modernste Halbleiter technologie ausgelegt und erm glicht auch bei lteren Kameras mit mechanischen Kontakten eine sichere Blitzausl sung Aufgrund der Vielzahl unterschiedlicher elektronischer Schaltungen in den Kameras zur Steu erung der Synchronisation k nnen wir jedoch
29. keine Haf tung f r etwaige Sch den an der blitzausl senden Kamera bernehmen Vor der Verwendung einer nicht markt blichen Kamera sollte deshalb der Kameraher steller kontaktiert werden Synchronisation ber Fotozelle Der Generator kann auch ber die eingebaute Fotozelle 18 ausgel st werden Das Ausl sen erfolgt dann durch das Auftreffen eines Blitzes welcher durch ein anderes Ger t abgegeben wurde Diese Betriebsart wird durch Bet tigung des Schalters 10 Kontroll LED leuchtet auf zugeschaltet Die Fotozelle ist als Impulsfotozelle ausge legt Sie kann deshalb nur funktionieren wenn der auftreffende Blitz st rker im Blendenwert ist als das Umgebungslicht Es ist deshalb darauf zu achten dass kein zu starkes Fremdlicht auf die Fotozelle fallen darf Wenn dies nicht zu vermeiden ist muss die Fotozelle mittels Schalter 10 abgeschaltet und der Blitz ber Kabel oder Funkfernbedienung ausgel st werden HENSEL VISIT International GmbH Strobe Wizard Plus 4 SYNC 13 TEST 14a 14b 14c Bedienungsanleitung Tria S Generatoren Synchronisation ber Funkfernausl sung Strobe Wizard Plus F r eine Blitzausl sung per Funksignal steht das neue System Strobe Wizard Plus bestehend aus Sender und Empfanger als Zubeh r zur Verf gung Die Funktechnik erm glicht ein Arbeiten unabh ngig von st renden Umwelteinfl ssen wie direktem Lichteinfall auf den Empf nger Blitze k nnen ausgel st werden auch
30. lash Check 6 aktiviert ist siehe unten 3 Akustisches Signal wenn AUDIO 8 eingeschaltet ist APD System Wird die Blitzenergie reduziert wird die gespeicherte Energie intern ber das APD System Automatic Power Drop abgebaut Dabei wird kein Blitz ausgel st Abge schaltete Generatoren werden automatisch entladen Einstelllicht Das Einstelllicht wird mit Taster 7 ein bzw ausgeschal tet Das Einschalten des Einstelllichtes ist nur wirksam wenn der angeschlossene Blitzkopf seinerseits einge schaltet und sein Einstelllicht auf ON geschaltet ist FREE PROP Wird Taster 9 auf FREE geschaltet kann die Helligkeit des Einstelllichtes ber den gesamten Blendenbereich unabh ngig von der gew hlten Blitzenergie eingestellt werden Wird Taster 9 auf PROP geschaltet ist die Helligkeit des Einstelllichtes proportional zur gew hlten Blitzener gie und zwar unabh ngig von der Stellung des Ein stelllichtreglers 21 Der jeweils aktive Modus wird durch das Aufleuchten der jeweiligen Kontroll LED angezeigt Das Einstelllicht kann mit Regler 21 in 1 10 Stufen ber einen Bereich von 6 Blendenwerten eingestellt werden Die Anzeige der jeweils gew hlten Helligkeit erfolgt digital an der 2 stelligen 7 Segmentanzeige 19 HENSEL VISIT International GmbH 19 Bedienungsanleitung Tria S Generatoren 5 IAS TI O 8 UDIO 12 SLOW 20 BIAS Sind beispielsweise mehrere Blitzger te im Einsatz ist es
31. m glich das Einstelllicht anzugleichen Soll die gew hlte Helligkeit um einen Blendenwert reduziert werden wird mittels Taster 5 1f eingestellt bei Reduzierung um 2 Blendenwerte 2f Die entsprechende Kontroll LED leuchtet auf Flash Check Flash Check Betrieb wird durch Bet tigung von Schalter 6 aktiviert Bei dieser Betriebsart verl scht die Einstell lampe sofort nach dem Abblitzen und leuchtet erst wieder auf wenn das Ger t wieder auf die eingestellte Leistung aufgeladen ist Sowohl korrekte Ladung als auch erneute Blitzbereitschaft werden dadurch angezeigt Die Abblitz kontrolle gibt die Sicherheit dass die Blitzlampen ge z ndet haben wenn mehrere Blitzger te Verwendung finden Audio Die Blitzbereitschaft nach dem Aufladen wird durch einen Signalton angezeigt Der Signalton wird durch Bet tigung von Schalter 8 zugeschaltet Kontroll LED leuchtet auf Die Tonh he wird ber die Ger teadresse zugeordnet Dadurch ist eine Melodie bei mehreren Generatoren m glich Ger teadresse Durch Bet tigung von Taster 17 kann jedem Generator eine Gerateadresse 0 9 zugewiesen werden Die ID Nummer wird im Display angezeigt Langsamladung Um den Betrieb leistungsstarker Generatoren auch an schw cher abgesicherten Stromnetzen zu erm glichen kann der Generator mit l ngerer Ladezeit geladen wer den Langsamladung wird durch Bet tigung von Schalter 12 aktiviert Kontroll LED leuchtet auf HENSEL VIS
32. n Das Stahlseil ist durch den Griff auf der R ckseite des Blitzkopfes zu f hren und durch eine geeignete Ose an der Abh ngung zu sichern HENSEL VISIT International GmbH 11 Bedienungsanleitung Tria S Generatoren 12 Warmeentwicklung Jeder Blitzkopf gibt durch das Einstelllicht und das Blitz licht W rme ab Diese W rme kann Ger teteile erheblich aufheizen so dass Verbrennungsgefahr beim Ber hren besteht Wegen der W rmeentwicklung d rfen Blitzkopf und Generator nicht in der N he von entflammbaren Gegenst nden betrieben werden Bei Dekorationen f r fotografische Zwecke ist auf ausreichenden Sicherheits abstand zu achten Dar ber hinaus ist es notwendig stets f r ausreichende Luftzufuhr zu sorgen und die L ftungsschlitze der Blitzk pfe und der Generatoren frei zu halten Blitzkopf oder Generator d rfen nicht unbeaufsichtigt be trieben werden Das Einstelllicht darf wegen berhitzungsgefahr nie l ng er als 20 Minuten auf voller Leistung betrieben werden Danach ist f r eine entsprechende Abk hlung zu sorgen Das Einstelllicht darf nicht als Ersatz f r Studiobe leuchtung verwendet werden sondern dient als Hilfe beim Scharfstellen des Objektives bzw zum Abschatzen des Licht Schattenverlaufes des Blitzlichtes Akklimatisierung Bei Standortwechsel des Generators mit Klimawechsel sollte der Generator vor Inbetriebnahme einige Zeit in dem Raum stehen in dem er benutzt wird Dadurch werden evt Kriechstr6m
33. nchro nization socket 4 of the generator The sliding switch of the receiver is used for channel selection There are 3 working channels available Depending on the working channel selected the flash can be triggered by pressing the TEST button or releasing the camera shutter In case of choosing the All option on the transmitter all flash units are triggered independently on the working channels selected In any case before starting up the instruction manual for Strobe Wizard Plus must be read carefully Test flash By pressing the TEST push button 13 test flashes can be released Flash power distribution of output sockets The flash power of the power packs Tria 1500 S 1500 Speed und 3000 S is distributed via the 3 output sockets 14 symmetrically Tria 6000 S provides fixed asymmetrical distribution as shown in the table below Socket 1 refers to 14a socket 2 to 14b and socket 3 to 14c power Table Sockets of Tria 6000 S socket 1 50 socket 2 50 socket 3 100 300J 3000 J 6000 J 1500 J 1500 J me 3000 J 3000 J 3000J 3000 J Thus due to the fixed asymmetrical power distribution of Tria 6000 S power pack it is possible to connect also flash heads with only 3000 J power output by using flash sockets 1 and 2 HENSEL VISIT International GmbH 39 User manual Tria S Power Packs READY
34. of fuse see table below Ue 230 V Ue 115 V 300 W halogen lamp 2 A quick 4 A quick 600 W halogen lamp 4Aquick Spare fuses for the power pack Spare fuses are integrated in the grip rod of the bracket Lamp connections Caution Before connecting lamp heads to the Tria power pack check the mains voltage and make sure that the head is allowed to be operated 115 V 230V Bi Voltage The EH PRO flash head line is specially developed for operation with the Tria generator The model type of each flash head is defined according to the type of the Tria generator It is also possible to use flash heads of series MH The table below gives you an overview of the appropriate flash head generator combi nation HENSEL VISIT International GmbH 35 User manual Tria S Power Packs 36 Generator Connection of flash heads Tria series EH PRO Series MH 1500 Speed 3000 6000 3000 6000 1500 S 3000 6000 3000 6000 3000 S 3000 6000 3000 6000 6000 S 3000 6000 3000 6000 The admissible load capacity of a flash head will be controlled by a flash head plug code In case of connecting an inadmissible flash head to the generator the code will block flash release or reduce the flash power of the flash head Only flash head extension cables with the plug code shall be used The cables can be ordered with precise specification from HENSEL VISIT Lamp heads flash head
35. ohne direkte Sichtverbindung und ber gro e Entfernungen hinweg gt 40 m bei freier Sicht Der Funksender wird mit der Kamera entweder ber das mitgelieferte Synchronkabel verbunden oder auf den Hot Shoe der Kamera aufgesteckt und sorgf ltig festge schraubt Seitlich wird mittels Schiebeschalter einer der drei Arbeitskan le oder die Schalterstellung All gew hlt Der Funkempfanger wird in die Synchronbuchse 4 des Generators eingesteckt und der gew nschte Kanal mittels Schiebeschalter gew hlt Es stehen 3 Arbeitska n le zur Verf gung Entsprechend der Wahl des Arbeitskanals kann der Blitz nun selektiv ber die Test Taste oder durch Bet tigung der Kamera ausgel st werden Wurde am Sender All eingestellt l sen alle Blitzger te aus unabh ngig von deren Kanaleinstellung Vor Inbetriebnahme ist in jedem Fall die Bedienungs anleitung zur Funkfernausl sung Strobe Wizard Plus zu lesen Blitzausl sung ber Taste Test Durch Bet tigung des Tasters 13 k nnen Probeblitze ausgel st werden Blitzleistungsverteilung der Ausgangsbuchsen Die Leistungsverteilung an den Blitzbuchsen der Gene ratoren Tria 1500 S 1500 Speed und 3000 S ist symmetrisch Beim Tria 6000 S verteilt sich die Blitz leistung entsprechend untenstehender Tabelle Buchse 1 entspricht 14a Buchse 2 entspricht 14b und Buchse 3 entspricht 14c HENSEL VISIT International GmbH 17 Bedienungsanleitung Tria S Generatoren 18 Tab
36. ommen werden e Generatoren d rfen nur an einem Stromnetz mit intaktem Schutzleiter angeschlossen werden e Nur Lampenstecker mit einwandfreien Kontakten ver wenden verbrannte und oder korrodierte Steckerkon takte k nnen Ursache von Br nden sein Defekte Stecker k nnen zu Sch den an den Steckerbuchsen f hren HENSEL VISIT International GmbH 7 Bedienungsanleitung Tria S Generatoren Kabel m glichst nicht am Studioboden verlegen um Besch digungen auszuschlieBen Ist eine Bodenver legung nicht zu vermeiden ist darauf zu achten dass die Kabel nicht durch Fahrzeuge Leitern etc be sch digt werden Besch digte Kabel und Geh use sofort vom Kundendienst ersetzen lassen Keine Gegenst nde in L ftungsschlitze Lampen oder Synchronbuchsen stecken L ftungsschlitze des Generators w hrend des Betriebes freihalten und f r ausreichende Luftzufuhr sorgen Keine Gegenst nde Werkzeuge Kaffeetassen etc auf dem Generator ablegen Blitzanlagen nicht in explosionsgefahrdeten Umge bungen verwenden Brennbare Materialien wie Deko rationsstoffe papiere u a nicht in unmittelbarer Umgebung der Generatoren und der Blitzlampen lagern um Brandgefahr zu vermeiden Generatoren sind vor Feuchtigkeit und Spritzwasser zu sch tzen Keine Zubeh rteile anderer Hersteller anschlie en auch wenn diese gleich oder hnlich aussehen Generatoren an Scheren oder Decken h ngend sind gegen Herabfallen doppelt zu sichern
37. on Staub und Schmutz befreit werden Achtung Vor der Reinigung ist das Ger t vom Stromnetz zu trennen Ger t nur trocken reinigen Instandhaltung und Reparaturen d rfen nur vom autorisierten Kunden dienst durchgef hrt werden Sicherung austauschen Sollte beim Durchbrennen der Schmelzsicherung 1 ein Austausch notwendig werden so darf dies nur bei vom Stromnetz getrenntem Ger t erfolgen Es d rfen nur 10 A Sicherungen Ansprechverhalten flink 10 AF ver wendet werden Reservesicherungen f r den Generator sind im Griffrohr des Trageb gels integriert Sicherungen f r Flash Heads Ue 230 V Ue 115 V 300 W Halogenlampe 2 A flink 4 A flink 600 W Halogenlampe 4 A flink Keinesfalls d rfen Sicherungen geflickt oder berbr ckt werden Nur Sicherungen mit hohem Schaltverm gen nach IEC 127 2 1 bzw EN 60127 2 1 verwenden Kera mikrohr Turnusm ige berpr fung Die nationalen Sicherheitsvorschriften verlangen eine intervallm ige Uberpr fung und Wartung elektrischer Anlagen und Ger te Generatoren und Zubeh r m ssen regelm ig auf ihre Betriebssicherheit berpr ft werden Eine j hrliche Durchsicht der Ger te dient der Sicherheit der Benutzer und erh lt den Wert der Anlage HENSEL VISIT International GmbH 23 Bedienungsanleitung Tria S Generatoren R cksendung an Kundendienst Um einen optimalen Schutz der Ger te beim Versand zu gew hrleisten
38. s from one climatic zone to the next the appliance should stand in the room in which it will be operated for some time before starting it up This prevents internal shortcuts caused by eventually con densing water Positioning Tria generators can be operated standing up or lying down pile up ring set 4 pcs Code No 9590521 Mains connection 230 V version Attention Before connecting the generator to the mains outlet make sure that the mains voltage matches the information given on the type label of the generator The type label can be found on the bottom of the appliance Multivoltage Version The generator adjusts itself for different main voltages Flash generators must only be connected to mains outlets with ground connection Insert the plug of the provided power cable into the mains connector 2 and then connect the cable to the mains outlet HENSEL VISIT International GmbH User manual Tria S Power Packs Fuses Outlets in the building Ue 230 V Ue 115 V Slow charging 10 A 16 A Normal charging 16 A 20 A Fuse for modeling lamp 1 The fuse 1 is a general lamp fuse Make sure that only 10 AF fuses with the required value 10 A quick are used Fuse for halogen lamp in flash head The halogen lamp in the head is protected by a 5 x 20 mm melting fuse Caution Make sure that depending on the mains voltage the right modeling lamp is in use and protected by the specified type
39. s the modeling lamp for on or off for PROP operation The modeling lamp output is proportional to the chosen flash power e Flash control By turning the flash control switch the flash output can be defined in 2 10 f steps over a range of 6 f stops e READY Lighting up signals flash readiness e TEST Pressing the TEST button enables manual flash release e SYNC Additionally one synchronization socket is available Remote 2 socket Using the second remote socket 16 you can connect several generators in order to control them from PC This function is not yet available HENSEL VISIT International GmbH User manual Tria S Power Packs Trouble shooting Er 01 Er 07 Those error messages appear when one or more heads have not triggered For reset press the corresponding 15 lamp control switch 15 19 20 Error Not triggered Er 01 Head 1 Er 02 Head 2 Er 03 Head 3 Er 04 Head 1 and 2 Er 05 Head 1 and 3 Er 06 Head 2 and 3 Er 07 Head 1 2 and 3 Er 21 Er 34 Error messages because of overheating Reset auto matically after a cooling down period Er 40 Er 43 Error messages concerning charging or other errors For reset switch the unit off by pressing the main switch 3 Please contact the HENSEL customer service immedia tely in case of multiple appearance of these error messages 3 8 Maintenance The Tria generator is in need of little maintenance by the user The unit should be dry cleaned from dust
40. s with halogen lamps which are not equipped with a cooling fan may not be used During quick flash sequences the flash tubes and therefore also the generator would be damaged Third party manufacturers Even though similar lamp sockets and plugs are used by other manufacturers as well lamps and flash heads from these manufacturers may not be connected to the Tria generator This requires in every case an adapter cord Ask your HENSEL agent about suitable adapter cords for your brand Number of flash heads connected Max 3 flash heads are allowed to be simultaneously con nected to the generator The maximum load capacity of the flash head may not be exceeded Power distribution Distribution of flash power is achieved symmetrically over the 3 flash sockets 14 HENSEL VISIT International GmbH 3 N OFF User manual Tria S Power Packs Mechanical connection of lamp plugs e Before connecting lamp plugs turn off the lamp control switches 15 and switch off the generator using main switch 3 e Only use flawless plugs and sockets The lamp plug is locked using a mechanical catch To do this insert the plug into the flash socket 14 slightly tilted forward and then press it tightly into the catch at the rear near the cable duct To disconnect the plug press the catch back and pull the plug upwards at the back at the cable duct Plugmatic The flash sockets 14 are fitted with the HENSEL safety system Plugmatic
41. tee for misprints The listed values are guide values and should not be understood as binding in a legal sense The values can differ due to tolerances in used components HENSEL VISIT International GmbH 27 User manual Tria S Power Packs 28 2 Table of contents 1 lmtroduellon Ca dee 27 2 Table of contents 28 3 General safety regulations 29 30 A Technlealdalare ssestnan a 31 5 Overview of controls 32 6 Stating Up y u asua ee ee 33 Safety hints 33 34 Acellmalzing 2er aa taka Au 34 POSIMOMING arena 34 Mains connection 34 FUSES onen sn nen tentenendon nian egog een 35 Lamp connections 35 36 Number of flash heads connected 36 Power distribution 36 Mechanical connection of lamp plugs 37 PIQgIYWAtUi6 2 awa au 2 Su etree st ce sia 37 Lamp switches ON OFF 37 7 ODTF L2IOR a uD S repeat a a 37 Switching ON and OFF 37 Synchronization 38 39 Flash power distribution of flash sockets 39 Flash power control 39 Flas
42. trigger the generator Triggering is then effected by an incoming flash which was emitted by another flashlight This mode of operation is switched on using switch 10 and displayed by control LED The slave is an impulse photocell It can only operate when the triggering flash has a higher f stop than the ambient light Please be aware that the ambient light that strikes the slave may never be too strong If this cannot be avoided please switch the slave off and release the flash by cable or radio signal synchronization via Strobe Wizard Plus For radio flash triggering the new HENSEL Strobe Wizard Plus consisting of transmitter and receiver is available as accessory The radio technology allows you to operate independently on environmental factors like ambient light that might interfere with the receiver You can even trigger flashes if your flash units are out of sight and over long distances gt 40 m free visibility The radio transmitter is to be connected to the camera using the provided synchronization cable or by attaching the transmitter to the hot shoe respectively Make sure that the unit is tightened carefully by the locking screw HENSEL VISIT International GmbH 4 YNC 13 TEST 14a 14b 14c User manual Tria S Power Packs The working channel can be selected using the sliding switch There are 3 working channels available and the option All The radio receiver is to be attached to the sy
43. ts tools coffee cups etc on the generator Flash systems must not be used in environments with explosion hazard Flammable materials like furnishing fabrics paper etc must not be stored in the im mediate vicinity of generators and flash lamps to prevent fire hazards Generators must be protected against humidity and spray water Do not connect accessories from other manufacturers even if they use the same or similar connectors Generators hanging from pantographs or ceiling must be doubly secured against falling down Do not flash into eyes at short distances smaller than 5 m because this can lead to eye damage Do not look directly into the flash reflector the flash lamp could be triggered inadvertently Regularly air closed rooms to prevent build up of inadmissible ozone concentrations which can occur due to the use of high powered flash systems During work in the studio generating much dust the appliance must be covered with suitable dust pro tection not during operation HENSEL VISIT International GmbH 4 Technical Data User manual Tria S Power Packs Model series Tria power pack 1500 Model type Speed 1500S 3000S 6000 S Rated energy 1500 J 1500 J 3000 J 6000 J Aperture 100 ASA t 1 60 2m distance Intensity Refl 1 MH 3000 1 MH 64 4 10 64 5 10 90 5 10 128 5 10 6000 Flash duration t 0 5 in s 1 EH PRO 3000 6000 1 1500 1 800 1 500
44. you can get a melody by setting different ID numbers Identification number By pressing push button 17 an identification number 0 9 can be related to each generator The ID number will be displayed Test flash By pressing button 13 test flashes can be released HENSEL VISIT International GmbH 41 User manual Tria S Power Packs 12 SLOW 16 REMOTE 1 19 20 EE EE 16 REMOTE 2 42 Slow charge To enable operation of high powered generators in mains networks with low load the generator can be charged with a longer charging time This is turned on using switch 12 control LED lights up When charged for the first time the generator switches automatically to slow charge for 10 sec The advantage of this is that when the unit has not been in use for some time the capacitors can be loaded and formatted better during the initial charging and prevent the blowing of a weak main fuse Remote socket Remote 1 socket Tria generator can be operated using the generator front panel or in the most important functions using the Cable Remote Control RC X which is available as accessory Code No 3310 The remote control unit will be connected via the supplied cable to the remote socket 16 of the generator Provided functions of the Remote Control RC X e STBY Pressing the STBY key switches the power pack to the stand by mode The displays 19 and 20 show EE EE e PILOT Pressing the PILOT key switche