Home

USER MANUAL IP day/night PTZ camera in weather

image

Contents

1. C i 53 5 Technical specifications lt lt 54 User manual SNC 670ID W GEN i El HA VIDEO TECHNOLOGES Safety precautions Caution CAUTION DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL Description of symbols Danger This symbol is intended to alert the user to the presence of un insulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to a person Warning This symbol is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance CE compliance Attention Any changes or modifications to this appliance which have not been explicitly approved of by the respective regulatory authority may lead to a prohibition of usage of this appliance This appliance complies with the CE guidelines SAN EE User manual SNC 670ID W HENAVIDEO TECHNOLOGIES Safety instructions e Before operating the appliance please read this manual carefully and retain it for further reference e Before cleaning the appliance it has to be switched off and unplugged from the power outlet Wipe the appliance with a soft damp cloth Do not use harsh cleansers or aerosols for cleaning The type label may not be replaced
2. Activex Version 1 0 1 9 and click update Note Do not move another page and disconnect the power of the device during the update Update will take approximately 1 minute Warning System will restart immediately This page displays information on the installed firmware version and the ActiveX components e Search Select the firmware file from your PC e Update Start the update process e Restart Restart the camera 41 SAN i EE User manual SNC 670ID W EMA VIDEC TECHNOLOGIES 4 5 Network 4 5 1 IP address Enable DHCP IP Address Netmask Gateway 0 0 0 0 1 s DNS 0 0 0 0 2 s DNS 0 0 0 0 HTTP Port 80 Submit e IP address Enter the 4 Byte IP address value from 0 to 255 Every network camera has to have its own IP address which can be identified in the network e Netmask Enter the 4 Byte subnet mask value from 0 to 255 By this the netmask can be identified in which the network camera is located e Gateway Enter the 4 Byte gateway value from 0 to 255 e First DNS Enter the 4 Byte DNS server address value from 0 to 255 The DNS server transforms the domain name into an IP address e Second DNS Enter the 4 Byte DNS server address value from 0 to 255 The DNS server transforms the domain name into an IP address e HTTP port Displays the specific HT TP port number Default is 80 e Submit Click here to apply the new network settings to the network c
3. MPEG4 O MPEG4 JPEG Pre set mode This mode is used in the SanView software e Resolution The resolution of each video stream depends on the compression The following values apply Single MPEG4 Video Stream 1 MPEG4 D1 720x576 MPEG4 Half D1 Video Stream 1 MPEG4 D1 720x288 MPEG4 MPEG4 Video Stream 1 MPEG4 D1 720x576 Video Stream 2 MPEG4 CIF 352x288 MPEG4 JPEG Video Stream 1 MPEG4 D1 720x576 Video Stream 2 JPEG D1 720x576 e Bitrate Bit rate mode o CBR Constant bit rate o CVBR Variable bit rate e JPEG settings o Quality HIGH NORMAL LOW o Frame rate 20 15 7 5 3 1 fps User manual SNC 670ID W SAN i El m SSRVIDEOQ TECHNOLOGES e MPEG4_1 setting o Bitrate 200 4000 Kbit sec o Bild rate 25 13 6 3 fps e MPEG4 2 setting o Bitrate 200 4000 Kbit sec o Bildrate 25 13 6 3 fps e Submit Click here to save the new settings 4 6 2 Camera settings g2 DENTI 091914 SMC 3700 Brightness 96 gt 0 255 Contrast 120 gt 0 255 Saturation 128 gt 0 255 default e On this page you can change the following picture settings o brightness 0 255 o contrast 0 255 o saturation 0 255 e Reset The picture settings are reset to brightness 96 contrast 120 saturation 128 e Submit Click here to save the new picture settings 47 SRN L EE User manu
4. OFF EXIT lt TS PTZ10X gt lt TS PTZ3X gt CAMERA SET gt FLICKER This function reduces picture flickering The default setting is OFF Set the flicker mode to ON in case the power source doesn t comply with the frequency CAMERA SET gt MIRROR This function can be used to display a horizontally mirrored picture The default setting is OFF 21 SAN EE User manual SNC 670ID W HENAVIDEO TECHNOLOGIES CAMERA SET gt APERTURE This function enables to show details and to emphasise picture borders The granularity is increased The default setting is 10 the aperture can be set from 0 15 CAMERA SET gt D ZOOM Switches on the 10x digital zoom CAMERA SET gt WB MODE The white balance function has 4 setting modes depending on the outside light The default setting is AWB MODE automatic white balance Depending on the light conditions the following settings are possible e AWB MODE from 3200 K to 6000 K e INDOOR up to 3200 K e OUTDOOR up to 5800 K e ATW MODUS from 2000 K to 10000 K CAMERA SET gt PIC FLIP The picture can be vertically mirrored The default setting is OFF CAMERA SET gt BLC The default setting for backlight compensation is OFF OFF backlight compensation BLC is not active ON backlight compensation BLC is active CAMERA SET gt D N MODE The IR cut filter operates in the following modes e AUTO MODE Automatic switching between colour mode
5. e Do not use attachments unless recommended by the manufacturer as they may affect the functionality of the appliance and result in the risk of fire electric shock or injury e Never install the appliance in areas exposed to water or other liquids e The camera housing complies with class IP 66 e The appliance has to be installed in a safe and stable location which is able to carry the weight of the appliance Quick stops excessive force and uneven surfaces may cause the appliance to fall causing serious injury to persons and damage to objects e Openings in the appliance if any are provided for ventilation to ensure reliable operation of the appliance and to protect if from overheating These openings must not be covered or blocked Please make sure that the appliance does not overheat e The appliance should only be operated from the type of power source indicated on the marking label If you are not sure of the type of power supplied at the installation location please contact your local dealer e An appliance which is powered through a polarized plug a plug with one blade wider than the other will fit into the power outlet only one way This is a safety feature If you are unable to insert the plug into the outlet try reversing the plug Do not defeat the safety purpose of the polarized plug e lf the appliance is powered through a grounding type plug the plug will only fit into a grounding type power outlet This is a safety
6. EYMDITA ITNVO TI VEYNVO dNLYS 4NOC LAS NVIS OLAV LIS Lasddd LIS VHUNVI LIS ANOd NANNAN NIVN SANTEG HA VIDEO TECHNOLOGIES 2 OSD menu 2 1 Overview User manual SNC 670ID W GRIN I El HA VIDEO TECHNOLOGES Main menu MAIN MENU DOME SETUP CAMERA SET AUTO SCAN TOUR PRAVACY PATTERN ALARM SECTOR EXIT Use the up down arrows to go the desired position Use the left right arrows to confirm your choice 2 2 Dome PTZ adjustments DOME SET CAMERA ID gt CAMIOOOOOOOOOOOO RECOVER OFF MANUAL SPEED 100 S AUTO FLIP OFF lt Y Default setting ZOOM SPEED FAST ALARM DISABLE LANGUAGE ENGLISH NEXT PAGE SAVE AND EXIT EXIT DOME SETUP gt CAMERA ID You can enter up to 16 characters using the left right arrows e Tomove from left to right to the next character press ZOOM e Tomove from right to left to the next character press ZOOM Blanks are marked with 17 e EE User manual SNC 670ID W BMAVIDEC TECHNOLOGIES DOME SETUP gt RECOVER The camera is able to return to those previous settings which were used before you operated the camera manually auto scan group tour preset pattern or sectors After the set time the camera goes into operation again in case it has been switched off The recovery time can vary between 15 99 seconds The default setting is OFF DOME SETUP gt MANUAL SPEED The manual pan tilt speed can be set from 10 se
7. N 1 8 Camera mounting Mount the camera onto a solid surface which is capable to carry the weight of the camera In case the screws included in the delivery are not adequate please make sure to use other suitable screws to ensure a safe camera installation 1 Fix the bracket to the desired location 2 If you use a tube cable channel please using 4 SCrews make sure to use the right size PT 3 4 Tr L 4 N vA i p 771 JZ 3 Assemble the camera 42 User manual SNC 670ID W SAN i El E HA VIDEO TECHNOLOGIES 1 9 Dimensions 167 mm 167 mm 1 10 PTZ control via Pelco D protocol Command Description Function Execute preset 1 165 Preset status display Open OSD main menu Navigation in OSD menu Command Button Tilt up arrow up down arrow down Pan right arrow right pan left arrow left Entry key Focus near focus 13 SAN i EE User manual SNC 670ID W HENAVIDEO TECHNOLOGIES 1 11 Diagnosis When the camera is switched on the DIAGNOSIS menu appears The following notification is displayed CAMERA ID 001 BAUD RATE 2400 BPS PAN ORIGIN TILT ORIGIN TX CONNECTION TEST OK CAMERA COMM TEST OK WAITING Pan origin test After the panning test the pan function is set to zero Tilt origin test After the tilting test the tilt function iss et to zero TX connection test 60 seconds countdown for TX connection test The camera has to receive a signal from
8. OSD button 15 User manual SNC 670ID W HOWA SOIAHYA OOTNAS s INTCON VINTI 90787090 LVG GUTVEDAN LIXA LIXA GNV YAVS 00 lt AHA HAVMNATA Sdd0077 HLVY COVE d d OOTHd TOOOLOYd SAKENS WARES SS LIXA HAYS LOV WAV Iv HOVd SNOIAHYA JA0 NO HALYNICHOOI NO 440 GI YOLIHS NO AAO 0I LASHYA NO 440 GI VYENYO AV Ta4aSIGQ ASO HOVA SNOIATYUA NOTIVZITVILINI SALYIS WHLSAS ATASIA ASO HOVa IXAN SOOT TILA LAaNT NUV IV ITONFHHLLVA A ILIL ON NUV IV LS LoS ON LYS NdaLLlvd LIX LIXH HAYS HAYS VLVO NOLIOV LLVd AVIASIO LLVd ONT A UNI AA LES AOWA Tad LIXA NO 440 H00N SSG OLNV COW N G LIXA LIXA ANY HAVS S wlooz dads OT AWIL TIYMG TO ON LASYYd TO daLS YNOL ITOXNOL JILIL YNOL TO ON YNOL LAS YNOL LIXH ANY HAVS HOVaA LXAN HSITDNHY JOVNDNVI LIX4 YOLOAHS NUV IV 16 O YNLL TIMO NO 44O oTa d IdvSIQ NUV IV NYYLLVA MOIQ AI44S LIXA NO 440 dtd DId LSVA au4as NOOZ AOVAVEd NO H4O SS4ATANY JAVS ON GMV ON M TATO dIiTH OLNV anOL MO NOILOHYIG X XX X XXX LIIL X XX X XXX NVd NO H4O NOOZ d NYOS OLNV S 3 001 AYEAS TVANVN TOLYSUUd QI LUSHYA NO AHO HOYYIN HO X XX X XXX JIONV ANY GOOG FTHAODHY LIS VEYNVO X XX X XXX d IONV LUVLS TOO ON L4SuYd NO AAO
9. PRESET button Re enter the number in the confirmation field The monitor displays CONFIRMED The menu page is then started automatically ENTER PASSWORD ENTER PASSWORD BY ENTERING PRESET CODE BY ENTERING PRESET CODE PASSWORD PASSWORD CONFIRM CONFIRMED CONFIRM CANCELLED lt CONFIRMED gt lt CANCELLED gt If a user enters a wrong PRESET number for PASSWORD or CONFIRM the monitor displays CANCELLED If a user enters a wrong PRESET number three times the previous monitor page is displayed NOTE Once a password has been created it has to be used to access the OSD main menu This also applies to changes The user has to know the password to make changes The device is delivered without a saved password DOME SETUP gt OSD DISPLAY The OSD ID is displayed if set to ON and can be switched of with OFF Use the left right arrows to make the settings OSD DISPLAY CAMERA LD OFF PRESET ID OFF Default setting SECTOR ID OFF COORDINATE ON PREVIOUS PAGE 19 SAN i EE User manual SNC 670ID W EMA VIDEC TECHNOLOGIES DOME SETUP gt OSD DISPLAY Camera information is displayed SYSTEM STATUS PROTOCOL PELCO D P BAUD RATE 2 9000 BEL FIRMWARE VER 2 01 UPGRADED DATE 24 01 08 lt MDefault setting CAMERA MODULE SDM100 PREVIOUS PAGE e Protocol and Baud rate are displayed according to the settings oft he DIP switch e Firmware version and data upgrade are ap
10. SNC 670ID W SAN El m HA VIDEO TECHNOLOGES c SanView software Every SANTEC IP camera comes with the SanView Lite software In order to change the network settings open the device adjustment page via the context menu also see brief instructions on SanView software Einstellungen SNC 380DN Ger t Netzwerkparameter Komprimierung Bild 1 P IP Adresse 212 12 37 132 nderung der Netzwerkparameter Subnetzmaske kann zum Verlust der 255 255 255 224 Verbindung f hren Verwendete Gateway Domainnamen m ssen 212 12 37 137 korrekt aufgel st werden Port Nummer DI bernehmen You will find the respective control elements on the network parameter tab To copy the parameters click on Apply Further details on how to add a camera to the SanView software can be found in the brief instructions on the SanView software Below are the default settings to login to the SanView software User ID admin Password santec 31 SAN EE User manual SNC 670ID W HENAVIDEO TECHNOLOGIES 4 Web interface 4 1 Calling up the camera web interface Open the Microsoft Internet Explorer and start the connection of the network camera as follows e Click on the URL field e Type in the URL address of the network camera and press the ENTER key You will then access the web interface of the camera The default IP address of the camera is 192 168 1 168 You need the user ID and the password in ord
11. external power supply unit Plug in the power cable it is recommended to use 12 V DC 2 A to the Power interface The camera has an analogue video output BNC If a monitor is directly connected to the analogue video output of the camera the monitor impedance has to be set to 75 Ohm Check the switch in case the video picture is not clear Plug in the video cable to the video output marked Video RS485 C D GND 1 TEST TEST 2 l analogue alarm inputs DC 12V IN POWER mi 10 User manual SNC 670ID W SAN i El m HA VIDEO TECHNOLOGES 1 5 DIP switch settings By default the DIP switch settings are as follows Termination TT Baud Rate Protocol ID By default the following settings apply e ID 01 e Baud rate 9600 e Protocol Pelco D These settings of the analogue camera module must not be changed because they are aligned with the RS 485 settings of the IP camera module 1 6 Reset the camera to default settings To reset the camera to default settings press and hold the reset button for 5 seconds 11 SRN L EE User manual SNC 670ID W EMA VIDEC TECHNOLOGIES 1 7 External RS 485 connection PTZ camera control can also be done by the RS 485 interface Please note the following The DIP switch SM10 is used for 100 Ohm DIP switch SW10 must only be used for the last camera at the bus even if only one camera is used Bus connection Camera 1 Camera 2 Camera 3 Camera
12. 010 06 02 Time 09 12 46 The Desired Time O Set Manually Date 2010 06 02 YYYY MM DD Time 09 09 v 06 v HH MM SS Synchronize with Computer Time Date 2010 06 02 Time 09 08 56 Synchronize with SNTP Server SNTP Server 0 pool ntp org Automatically Adjust for Daylight Saving Time Changes Time Zone GMT 01 Amsterdam Berlin Rome v 35 SAN EE User manual SNC 670ID W EMA VIDEC TECHNOLOGIES 4 4 System settings 4 4 1 Time date The Local Time Date 200 Time The Desired Time Set Manualy Date 2010 05 10 YYYY MM DD Time 09 13 28 HH MM SS Synchronize with Computer Time Date 2010 05 10 Time Synchronize with SNTP Server SNTP Server 0 pool ntp org V Automatically Adjust for Daylight Saving Time Changes Time Zone GMT 01 Amsterdam Berlin Rome Submit e Local time The local time is the one as set in the camera e Desired time You can change the time which is set in the camera as follows o Set manually Select the desired time and date from the drop down list o Synchronize with computer time If you select this option the computer time date is transferred to the camera o Synchronize with SNTP server If you select this option the SNTP server time date is transferred to the camera e Automatically adjust for daylight saving time changes This option activates the automatic adjustment
13. Bl HA VIDEO TECHNOLOGES 2 6 Tour There are 8 programmable tours available Each tour can contain up to 60 preset positions TOUR FS ET TOUR NO DI TOUR TITLE gt TOURO 10000000000 TOUR STEP 01 lt 4q Default setting PRESET NO 001 DWELL TIME 03 SPEED 200 70 SAVE EXIT TOUR gt TOUR NO There are 8 tour numbers available Use the left right arrows to select a tour number TOUR gt TOUR TITLE You can assign a name to a tour consisting of up to 16 characters Use the left right arrow to select the characters To move from left to right press ZOOM To move from right to left press ZOOM Blanks are indicated with TOUR gt TOUR STEP Each tour can consist of up to 60 steps preset positions All presets can be run with different speeds and dwell times Use the left right arrows to select a tour step TOUR gt PRESET NO Assigns a preset number to the current step Use the left right arrows to select a preset number TOUR gt DWELL TIME A dwell time is assigned to the current step The dwell time can be from 1 99 sec The default setting is TOUR gt SPEED Defines the speed of the current step The speed can be from 10 sec to 200 sec The default setting is 200 sec Use the left right arrows to select a value TOUR gt SAVE Saves the settings of the current tour step TOUR gt EXIT Exit the menu 25 SAN EE User manual SNC 670ID W BMAVIDE
14. C TECHNOLOGIES 2 7 Privacy zones The camera contains 4 privacy zones which can be used to hide certain areas PRIVACY Sil PRIVACY NO 01 DISPLAY OFF Default setting ACTION MOVE SAVE EXIT PRIVACY gt PRIVACY NO There are 4 privacy zones available Use the left right arrows to select a zone number PRIVACY gt DISPLAY Use the left right arrows to show the current privacy zone ON This area is displayed as a grey square The default setting is OFF PRIVACY gt ACTION In order to set the position of a privacy zone do the following e Use the left right arrows to select MOVE e Press FOCUS e Use the arrows to go to the desired position e Press FOCUS to save the position In order to set the size of a privacy zone do the following e Use the left right arrows to select ADJUST e Press FOCUS e Use the arrows to go to the desired position e Press FOCUS to save the size PRIVACY gt SAVE Saves the settings of the current privacy zone PRIVACY gt EXIT Exit the menu 26 User manual SNC 670ID W GRIN I El HA VIDEO TECHNOLOGES 2 8 Patterns There are 8 programmable patterns available PATTERN SET PATT NO 01 Default setting PATT TITLE PATTERNO10000000 DATA FILL 100 SAVE EXIT PATTERN gt PATT NO There are 8 patterns available Use the left right arrows to select a pattern number PATTERN gt PATT TITLE You can assign a name to a pa
15. E Mail address to which the e mails are to be sent e Send count 1 8 Number of files attached to an e mail e Submit Click here to apply the new network settings to the network camera 44 User manual SNC 670ID W SEN i EN E SSRVIDEOQ TECHNOLOGIES 4 5 5 DDNS dynamic domain name system Enable DDNS Function DDNS Host Name test dyndns org DDNS Account test DDNS Password ewes e DDNS host name IP address of DDNS server Can be entered as 4 Byte IP address or as domain name e DDNS account Account on DDNS server e DDNS password Password of account on e mail server e Submit Click here to apply the new network settings to the network camera 4 5 6 Event protocol Date and Time 1 2000 01 01 01 10 06 login on ffff 192 166 1 169 On this page the events are displayed You can browse in the events by clicking on the buttons first page previous 20 and next 20 45 SANTEC EEEAVIDEO TECHNOLOGIES 4 6 Video settings 4 6 1 Encoding Video Codec Resolution Rate Control JPEG Setting Quality Frame Rate MPEG4 1 Setting Bit rate Frame Rate MPEG4 2 Setting Bit rate Frame Rate Submit User manual SNC 670ID W MPEG4 JPEG M4 D1 JPEG D1 k CBR high 20fps 2000 25fps 2000 N A e Compression Setting of the video streaming mode o Single MPEG4 o MPEG4 Half D1 o MPEG4
16. EOQ TECHNOLOGES NOTES 55 Your local distributor SANTEC HA VIDEO TECHNOLOGIES www santec video com
17. M gt EXIT Exit the menu 28 User manual SNC 670ID W GRIN I El HA VIDEO TECHNOLOGES 2 10 Sector SECTOR SET Start Position SECTOR NO 01 SECTOR ID gt SECTORI SECTOR START XXX X XX X SECTOR END i XXX X XX X SAVE End Position EXIT Default setting SECTOR gt SECTOR NO There are 8 sectors available Use the left right arrows to select a sector number SECTOR gt SECTOR ID You can assign a name to a sector consisting of up to 16 characters Use the left right arrow to select the characters To move from left to right press ZOOM To move from right to left press ZOOM Blanks are indicated with SECTOR gt SECTOR START Press FOCUS to select a start position Move to the desired position by using the arrows Confirm your choice with FOCUS SECTOR gt SECTOR END Press FOCUS to select an end position Move to the desired position by using the arrows Confirm your choice with FOCUS SECTOR gt SAVE Saves the settings of the current sector SECTOR gt EXIT Exit the menu 29 User manual SNC 670ID W SANTEC HENAVIDEO TECHNOLOGIES 3 IP settings The SANTEC IP cameras come with the following default settings IP address 192 168 1 168 Subnet mask 255 255 255 0 Gateway 0 0 0 0 DNS server 0 0 0 0 User ID admin Password 9999 To retain the default settings press the reset button There are the following 3 options to change the IP address o
18. M IM MM PRESET 33 SAN EE User manual SNC 670ID W EEA VIDEO TECHNOLOGIES Start autoscan Digital output relay on Digital output relay off G enemas Audio on web interface gt camera Audio off web interface gt camera Storage location for snapshots and video sequences Save snapshot Start recording the video sequence is saved as AVI file Stop recording Note e In order to activate the 2 way audio function press the of and BE buttons e In order to save a snapshot or a video sequence select the storage location by using the Q button 34 User manual SNC 670ID W 4 3 Setting overview SANTET Main Menu Basic Setting System Date and Time Timestamp i User Setting Language Setting RS485 Setting PTZ Setting Device Name i Update Firmware gaa Network WAN Setting SNTP Setting FTP Setting SMTP Setting DDNS Setting i Event Log Gl Video Video Setting i Camera Setting S Audio i Audio Setting S Advanced Setting Motion Detection Motion Detection Alarm Alarm Setting SD Card SD Card Setting i SD Card FileList Record Record Setting Schedule Record D SANTEC HENAVIDEO TECHNOLOGES ADMINISTRATOR S PAGE LIVE VIEW Data and Time Setting Data and Time Setting The Local Time Daylight Saving Time Is Acitve Date 2
19. SANTEC REA VIDEO TECHNOLOGIES IP day Inigh t PTZ camera in weather proof housing Model SNC 670ID W Version 1 1 0910 engl A6 Dear customer Thank you for purchasing a high quality SANTEC device We recommend that you read this manual thoroughly before operating your new system for the first time Please follow all instructions and observe the warnings contained in this manual Please contact your local dealer or use the SANTEC Service Hotline if you have any questions or if you wish to claim for a service or warranty You will find further information on our website www santec video com SANTEC Service Hotline 49 900 1 72 68 32 49 900 1 SANTEC if available from your country support santec video com All rights reserved This publication may not be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the written prior permission of SANYO VIDEO Vertrieb AG No reproduction of any part or excerpts thereof are permitted Errors excepted Specifications are subject to change without notice for quality improvement SANTEC is a registered trademark of SANYO VIDEO Vertrieb AG All other companies or products mentioned in this publication are trademarks registered trademarks or brands of the respective company They are not connected in any way with SANYO VIDEO Vertrieb AG copyright by SANYO VIDEO Vert
20. a controller or a video for a duration of 60 seconds Once the correct signal is received the TX connection test says OK If the notification Not Tested is displayed on the monitor e the camera didn t receive any signal e the camera hasn t received a readable signal e protocol Baud rate and RS 485 connector should be checked Camera communication test The camera communication test is initialised automatically Before the installation these 4 tests should be completed with OK Once all tests are okay the following notifications appear on the monitor NOW EEPROM CHECKING and ALL DATA INITIALIZING The camera is now ready to be used 14 User manual SNC 670ID W SEAN i El Bl HA VIDEO TECHNOLOGES 1 12 Adjustment of analogue camera module The camera adjustments of the analogue camera module are done by an OSD on screen display menu Follow the instructions in chapter OSD menu for more detailed information The OSD menu can be displayed by using the web interface of the camera on the page live view In order to navigate through the OSD menu please use the arrow buttons To confirm your selection press the button The SanView software also enables access to the camera OSD menu via the network To call up the OSD menu press the OSD button on the PTZ tab PTZIOSD R 4 7 05 In order to navigate through the OSD menu please use the arrow buttons To confirm your selection press the
21. al SNC 670ID W EMA VIDEC TECHNOLOGIES 4 7 Audio settings Audio OFF Audio Out Volume 2 From i min 4 max e Audio Set the audio mode to o OFF audio is turned off one way audio only from camera to PC o two way audio in both directions e Audio out volume 0 4 e Submit Click here to save the new audio settings 48 User manual SNC 670ID W SAN i EN m EEEAVIDEO TECHNOLOGES 4 8 Extended settings 4 8 1 Motion detection Motion Detection Enable Disable a Lowest 50 ser Setting Submit e Motion detection Activation deactivation of motion detection e Sensitivity Set the sensitivity level of the motion detection O O O O O Lowest Low Medium High Highest e CCD reference CCD reference 20 50 e Motion detection mask Click on the picture to set or to delete an element of the motion detection mask If a motion occurs in the marked field it will be detected e Submit Click here to save the new motion detection settings 49 SAN i EE User manual SNC 670ID W BMAVIDEC TECHNOLOGIES 4 8 2 Alarm settings Alarm In Sensor ON OFF Active Type Low Alarm Out Relay JON OFF Active Type Low Trigger an Alarm When Ethernet Is Lost Alarm Relay Duration 0 second Second s e Alarm in sensor Activate deactivate the alarm input o Active type low This means 0 V The camera will trigger an alarm if the ala
22. amera 42 User manual SNC 670ID W GEN i El HA VIDEO TECHNOLOGES 4 5 2 SNTP time server for time synchronisation SNTP Server D pool ntp org Submit e SNTP server IP address of the SNTP server Can be entered as 4 Byte IP address or as domain name e Submit Click here to apply the new network settings to the network camera 4 5 3 FTP FTP Server 192 168 1 2 Port 21 User Name Password File Upload Path default folder Submit e FTP server IP address of the FTP server Can be entered as 4 Byte IP address or as domain name e Port Port number of the FTP server e User name User name to login to the FTP server e Password Password to login to the FTP server e File upload path Folder path of FTP server in which the video data is to be stored e Submit Click here to apply the new network settings to the network camera 43 SAN EE User manual SNC 670ID W EMA VIDEC TECHNOLOGIES 4 5 4 SMTP E My Server Requires Authentication Account Name Password Sender SMTP Server 192 168 1 1 Email Address Storage Setting Send Count 4 Submit If necessary enable the option My server requires authentication e Account name Account on e mail server e Password Password of account on e mail server e Sender This information is displayed as e mail sender e SMTP server IP address of SMTP server Can be entered as 4 Byte IP address or as domain name e E mail address
23. and black white mode e NIGHT MODE The camera always remains in black white mode e DAY MODE The camera always remains in colour mode The default setting is AUTO MODE CAMERA SET gt DSS MODE Digital slow filter This function determines the shutter speed The shutter speed is increased to accumulate the light longer The values can be set to 2x 4x 128x The default setting is OFF CAMERA SET gt EXIT Exit the menu 20 User manual SNC 670ID W GRIN I El HA VIDEO TECHNOLOGES 2 4 Preset PRESET SETI PRESET NO 001 PRESET ID PRESETOOL PAN XXX XX TILT XXX XX SAVE EXIT lt Default setting PRESET gt PRESET NO There are 165 preset numbers available Use the left right arrows to select a preset number PRESET gt PRESET ID You can assign a name to a preset position consisting of up to 16 characters Use the left right arrow to select the characters To move from left to right press ZOOM To move from right to left press ZOOM Blanks are indicated with PRESET gt Pan XXX X Tilt XX X The coordinates of the preset position are displayed PRESET gt SAVE This function savest he preset position In order to set a preset position please follow these steps Exit the OSD menu of the camera module Use the arrows and zoom button to move to the desired position Once the position is selected call up the PRESET menu Enter the desired preset number in
24. c to 200 sec The default setting is 100 sec DOME SETUP gt AUTO FLIP Use the left right arrows to turn the auto flip function on off The default setting for auto flip is OFF DOME SETUP gt ZOOM SPEED Zoom speed can be set to FAST or SLOW Use the left right arrows to make the setting The default setting is FAST DOME SETUP gt ALARM The alarm function is activated by switching on the ENABLE mode Use the left right arrows to make the setting The default setting is DISABLE DOME SETUP gt LANGUAGE English Italian and Polish are available plus some other languages Use the left right arrows to make the setting The default setting is ENGLISH DOME SET SYSTEM LOCK PASS WORD lt 4 Default setting OSD DISPLAY INITIALIZATION SYSTEM STATUS PREVIOUS PAGE DOME SETUP gt SYSTEM LOCK Saved data is stored is protected by a password Changes are only possible using the correct password Set the System Lock to ON to get to the password page Use the left right arrows to make the settings The default setting is OFF 18 User manual SNC 670ID W GRIN I El Bl HA VIDEO TECHNOLOGES DOME SETUP gt PASSWORD Use the left right arrows to enter the password on this page The password has to contain numbers from 001 to 255 The default password is 99 ENTER PASSWORD BY ENTERING PRESET CODE PASSWORD mm CONFIRM 24 In the password field enter a number from 001 255 using the
25. er to access the web interface Password The default user ID is admin and the default password is 9999 Note When you call up the camera web interface it may happen that you are prompted for an ActiveX installation Please note that the Internet Browser settings allow the installation of ActiveX components A ee s 2 4 x SY Google J p eS m o r Surveilance Wa Idi gt 5 v LT v Seite Sicherheity Extras v r e vertrauen und die Installation zulassen m chten Diese Website m chte das folgende Add On installieren NetCamViewer cab voi SNC 390DN W O MPEG4 1 720x576 ele ala 1 39 User manual SNC 670ID W SAN i El m SSRVIIDIEQ TECHNOLOGES 4 2 Live View ADMINISTRATOR S PAGE LIVE VIEW SNC 670ID W JPEG 720x576 ss je I ole pio PRESET 1 W ta Tror 41 W ae S R PATTERN 1 Sy S SS S S SS BS SL Auro EN RL 201 Do ACE OBO Seve os 1714 25 SNC670ID W DQ CW 2 stor ADMINISTRATOR S PAGE I Page for camera adjustments I LIVE VIEW Wasa Page for Live View G Live View with 50 resolution Q Live View with defined resolution PTZ control e pan e tilt e confirmation OSD menu p PTZ speed S slow F fast Oj gt oom in 97 l LlLD d ctloL LlClCl I l l lI Uy ZOO
26. f the camera a IP finder software Every SANTEC IP camera comes with the IP finder software IP Utility MAC Address Gateway Subnet Mask Bootproto wabPnrt 2 160 10 234 2 160 10 236 168 10 233 2 166 10 230 2 168 10 230 168 10 235 b 10 231 b 10 249 U0TE 44001 YEE 001E440013A49 001E440017E6 001544001 755 001544331380 001E440013 0C 001544001 797 OUTE 44001 766 OUTE 44001 767 198 166 IO 215 192 160 10 216 192 166 10 216 192 166 10 210 192 166 10 210 192 160 10 210 255 205 255 0 255 255 255 0 255 255 255 255 65 255 255 65 255 0 255 65 265 fon 255 255 0 255 255 255 0 255 255 255 0 JRR IRG PEA f static static static static static static static static static ctatir r te g g g g q q q g g q 4 2 2 160 10 232 1 AA 1 241 NAF ANN 79 NT Dynamic IP IP Address 192 168 10 234 Mac Address 001E440017EE bree Default Gateway 192 168 10 218 ID SubNet Mask 25 265 25 Password lt 1 dd lt IP Find List Clear IP Change Web Config Select the camera from the list by double clicking Change the IP settings to the new settings Enter the user name ID and the password Click on IP Change b Camera web interface You will find the description of the web interface in the following chapter 30 User manual
27. feature If your outlet does not have the grounding plug receptacle contact your local electrician e Route power cords and cables in a manner to protect them from damage by being walked on or pinched by items places upon or against them e For protection of the appliance during a lightning storm or when it is left unattended and unused for a longer period unplug the appliance from the wall outlet Disconnect any antennas or cable systems that may be connected to the appliance This will prevent damage to the appliance due to lightning or power line surges e Do not overload wall outlets and extension cords as this can result in a risk of fire or electric shock e Never insert items into the openings of the appliance They may touch parts under electric current which may cause an electric shock e Never pour any liquids over the appliance User manual SNC 670ID W GRIN I El Bl HA VIDEO TECHNOLOGES e In case of any operating interruption or a complete operating failure please switch off the appliance and disconnect it from the wall outlet Never attempt to service or repair the appliance yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel e When replacement parts are required be sure that the service technician uses replacements parts specified by the manufacturer or that have the same characteristics as the original part Unauthorized substitu
28. l appliance items are included in the delivery Should items be missing do not operate the appliance and contact your local dealer Never attempt to repair the appliance yourself This should only be done by qualified service personnel Improper handling of the appliance will invalidate the warranty Items included in the delivery 1x camera SNC 670ID W 1x SanView Lite software 1x cable adapter BNC socket 1x IP finder software 7x screws 1x user manual 2x connection plug SAN EE User manual SNC 670ID W BMAVIDEC TECHNOLOGIES 1 Installation also see the pictures on the following pages This camera is a PTZ camera in a vandal proof housing class IP 66 You will find the technical data at the end of the manual 1 1 Camera overview 1 Adapter for mounting plate 2 Screw PT 7 3 DIP switch 4 Distributor 5 Camera module 1 2 Connections l Ethernet connection ee Power supply 12 V DC User manual SNC 670ID W SAN i El m HA VIDEO TECHNOLOGES Audio input output Alarm input output SRN L EE User manual SNC 670ID W HENAVIDEO TECHNOLOGIES 1 3 How to open the housing Open the housing by carefully loosening the housing s screws Pull off the housing module from the camera module Make sure not to damage the rubber gasket Improper handling of the appliance will invalidate the warranty 1 4 Connections for power supply and video The camera can be powered by 12 V DC using an
29. nguage Language English e Language Select your language o English o German e Submit Click here to apply the new language settings to the network camera 38 User manual SNC 670ID W 4 4 5 RS 485 settings BaudRate Type ID SANTEC HA VIDEO TECHNOLOGES 9600 Y 8 N 1 The RS 485 settings define the communication via the RS 485 interface between the camera IP module and the camera PTZ module e Baud rate 2400 4800 9600 19200 38400 57600 115200 e Type Type of command strings 8 N 1 8 E 1 8 O 1 7 N 1 7 E 1 7 0 1 e ID ID of external device O O O O O O O O O O O O O e Submit Click here to apply the new RS 485 settings to the network camera Note To ensure a trouble free PTZ control of the camera the RS 485 settings have to match the DIP switch settings 39 SAN EE User manual SNC 670ID W EEEAVIDEO TECHNOLOGIES 4 4 6 PTZ settings preseT 1 eee via PTZ control e pan e tilt PTZ speed S slow F fast Zemin Z min Select preset number Save preset position Go to preset position 40 User manual SNC 670ID W SAN i El m HA VIDEO TECHNOLOGES 4 4 7 Camera name Device Name SNC 390DN W e Camera name Enter the name title of the camera e Submit Click here to apply the new camera name to the network camera 4 4 8 Update firmware Software Version SNC 390DN W 2 2 00 1E44001785
30. o FTP file format can be set to AVI JPEG e Submit Click here to save the new recording settings 52 User manual SNC 670ID W User manual SNC 670ID W SEN i El m EEEAVIDEO TECHNOLOGES 4 8 4 2 Recording schedules Monday From 00 00 To 09 00 Monday v From 15 gt 00 To 21 00 Tuesday gt From 00 00 To 23 59 F Monday From 00 00 To 00 00 El Monday From 00 00 To oo 00 E Monday From 00 00 O To 00 00 E Monday From 00 00 gt To 00 00 0123456789 1011 1213 1415 1617 1819 20 21 2223 00 00 09 00 TORETE 15 00 21 00 RE CONO 2 59 Submit Remove All Schedules e You can set up to 7 schedules in the camera e Submit Click here to save the new schedule settings e Remove all schedules All existing schedules are deleted 53 SAN EE User manual SNC 670ID W EEEAVIDEO TECHNOLOGIES 5 Technical specifications Tiltange 1908 _ j Number of tours 18 C j Number of atterns 18 _ D1 720x576 half D1 720x288 CIF 352x288 MJPEG MPEG4 Video streaming Single MPEG4 D1 max 25 fps Single MPEG4 half D1 max 25 fps Dual MPEG4 D1 max 20 fps MPEG4 CIF max 20 fps Dual MPEG4 D1 max 25 fps MJPEG D1 max 20 fps Schedule Alarm input output RS 485 O RS 485 Voltage Subject to technical changes without prior notice Errors excepted 54 User manual SNC 670ID W SAN i EN m SSRVID
31. ormat SANTEC HA VIDEO TECHNOLOGES ON OFF Submit ON OFF Submit only Alarm Record Support 3 75 GB 0 e SD card enable Activate deactivate the SD card e SD card rewrite Activate deactivate the rewriting of the SD card e Format The SD card is being formatted e Submit Click here to save the new SD card settings 4 8 3 2 SD card content Filelist of SD Card Filename PUPP ELEC EC CEE CE CCEE CT 20100416 jpg Date Time Size 2010 04 16 15 24 22 39K Delete 1 file and 3938176 KBytes free e This page displays the content of the SD card e Click on the respective file name to open it e Click on Delete to delete the file 51 SANTEC EMA VIDEO TECHNOLOGIES 4 8 4 Recording 4 8 4 1 Recording settings Schedule Record Upload Via FTP Schedule Record Save Into SD Card Alarm Record Upload Via FTP Z Alarm Record Save Into SD Card Alarm Record Upload Via SMTP jpeg only PreAlarm Buffer 0 Second s SD File Format AVI FTP File Format AVI Submit e On this page you can set the recording modes o Schedule record upload via FTP Schedule record save into SD card Alarm record upload via FTP Alarm record save into SD card Alarm record upload via SMTP e mail sending O O O O e Additional setting options o Buffer Pre alarm buffer can be set to 0 1 2 3 seconds o SD file format can be set to AVI JPEG
32. plied when running updates DOME SETUP gt INITIALIZATION Using this function all saved data of tour tc 66 T1 66 GG 11 preset sector privacy or pattern are deleted INITIALIZATION TOUR CLEAR PRESET CLEAR SECTOR CLEAR PRIVACY CLEAR PATTERN CLEAR LOAD OPTIMIZED DEFAULT Use the left right arrows to delete saved data TOUR CLEAR TOUR CLEAR ARE YOU SURE YES NO If you press FOCUS and the curser is set to YES saved data is deleted After that every element such as preset sector etc blinks and appear for approx 2 3 seconds on the screen Then the screen displays the previous page In order to delete the saved data and to reset to default settings select LOAD OPTIMIZED DEFAULT The following page appears 20 User manual SNC 670ID W GRIN I El Bl HA VIDEO TECHNOLOGES LOAD OPTIMIZED DEFAULT ALL DATA INITIALIZING ARE YOU SURE YES NO To delete the data select YES and press FOCUS The screen displays ALL DATA INITIALIZING for 5 7 seconds The previous menu page is displayed automatically DOME SETUP gt SAVE AND EXIT Data is saved and the page is exited DOME SETUP gt EXIT The page is exited without saving any data 2 3 Camera adjustments CAMERA SET CAMERA SET FLICKER i OFF MIRROR OFF APERTURE gt LO FLICKER D ZOOM DEF BLC WB MODE AWB EXIT PIC FLIP OFF BLC OFF D N MODE AUTO DSS MODE
33. rieb AG User manual SNC 670ID W Table of contents Safety precautions Safety instructions About this user manual 1 3 How to open the housing 1 4 Connections for power supply and video 1 5 DIP switch settings 1 6 Reset the camera to default settings 1 7 External RS 485 connection 1 8 Camera mounting 1 9 Dimensions 1 10 PTZ control vial Pelco D protocol 1 11 Diagnosis 1 12 Adjustment of analogue camera module 2 OSD menu 2 1 Overview 2 2 Dome PTZ adjustment 2 3 Camera adjustments 2 4 Preset 2 Privacy zones 2 8 Patterns 2 9 Alarm 3 IP settings 4 Web interface 4 1 Calling up the camera web interface 4 2 Live view 4 3 Setting overview 4 4 System settings 4 4 1 Time date 4 4 2 Time stamp 4 4 3 User 4 4 4 Language 4 4 5 RS 485 settings 4 4 6 PTZ settings 4 4 5 Camera name SANTEC HA VIDEO TECHNOLOGES SAN i EE User manual SNC 670ID W HENAVIDEO TECHNOLOGIES 4 5 Network 42 4 5 1 IP address 42 4 5 2 SNTP time server for time synchronisation lt lt lt 43 453 FTP fg 4 5 5 DDNS dynamic domain name system 45 4 5 6 Event protocol 45 4 6 Video settings ss 46 4 6 1 Encoding U 46 4 6 2 Camera settings 47 4 7 Audio settings 48 4 8 Extended settings 49 4 8 1 Motion detection 49 4 8 2 Alarm settings 50 4 8 3 SD card WW 50 48 3 1SD cardsettings ss eee 51 4 8 3 2 SD card content 51 4 8 4 Recording 52 4 8 4 1 Recording settings eee 52 4 8 4 2 Recording schedules
34. rm input has 0 V To achieve 0 V at the alarm input the contacts are closed o Active type high This means 3 3 V The camera will trigger an alarm if the alarm Input has 3 3 V To achieve 3 3 V at the alarm input the contacts are not closed e Alarm out relay Activate deactivate the alarm output o Active type low This means 0 V If the camera triggers an alarm the alarm output has 0 V o Active type High This means 3 3 V If the camera triggers an alarm the alarm output has 3 3 V O e Trigger an alarm when Ethernet is lost The camera can trigger an alarm if the network connection is interrupted e Alarm relay duration You can set how long the alarm output should be active since the alarm is not being triggered anymore o 0 second The alarm output is set to inactivity immediately after the alarm 10 seconds The alarm output is set to inactivity 10 seconds after the alarm 30 seconds The alarm output is set to inactivity 30 seconds after the alarm 1 minute The alarm output is set to inactivity 1 minute after the alarm Endless The alarm output remains active until the alarm output is manually set to e9 inactivity press button on the live view page of the web interface O O O O e Submit Click here to save the new alarm settings 50 User manual SNC 670ID W 4 8 3 SD card 4 8 3 1 SD card settings SD Card Enable SD Card Rewrite Total Size Current Usage SD F
35. the PRESET NO field Select SAVE to store the settings The curser is positioned at PRESET NO and the next preset number is displayed PRESET gt EXIT Exit the preset menu DA SAN EE User manual SNC 670ID W BMAVIDEC TECHNOLOGIES 2 5 Auto scan AUTO SCAN SET START ANGLE XXX X XX X END ANGLE XXX X XX X DIRECTION CW ENDLES OFF SPEED 20 8 DWELL TIME 03 SAVE AND EXIT EXIT m Default setting AUTO SCAN gt START ANGLE Press FOCUS to select a start position Move to the desired position by using the arrows Confirm your choice with FOCUS AUTO SCAN gt END ANGLE Press FOCUS to select an end position Move to the desired position by using the arrows Confirm your choice with FOCUS AUTO SCAN gt DIRECTION You can choose from 2 directions e CW clockwise default setting e CCW counter clockwise AUTO SCAN SET gt ENDLESS The AUTO SCAN function can be used endlessly Use the left right arrows to make the settings The default setting is OFF AUTO SCAN gt SPEED Speed settings ara available from 1 sec to 35 sec The default setting is 20 sec AUTO SCAN gt DWELL TIME Use the left right arrows to set the dwell time It can vary from 1 30 seconds The default setting is 1 sec AUTO SCAN gt SAVE AND EXIT This function savest he settings and exits the auto scan menu AUTO SCAN gt EXIT Exit the menu DA User manual SNC 670ID W GRIN I El
36. tions may result in fire electric shock or other hazards e Upon completion of any service or repairs to the appliance ask the service technician to perform safety checks to verify that the appliance is in proper operating condition e The appliance should only be installed by qualified service personnel and has to comply with local specifications and regulations e Never point the camera at an object with a high degree of luminance Bright vertical or horizontal lines can result in a distortion outshine of the entire image on the monitor This artifact is not an error but a particularity of semiconductor CCDs when they are directly exposed to a powerful light source e Atthe installation site the camera has to be adjusted to the given light conditions see OSD e Please respect the local legal regulations on waste if you need to dispose of discarded appliances This symbol means that electrical appliances need to be disposed of properly and not x simply with unsorted household refuse Please respect local regulations on waste disposal About this user manual This manual aims at assisting the user on how to operate camera SNC 670ID W This manual is subject to rigid quality control However no guarantee can be given that mistakes are not present We reserve the right to make changes to the manual without prior notice Before operating the appliance please read this manual carefully and retain it for further reference Verify that al
37. to summer winter time e Time zone This is the time zone in which the camera Is located This option Is important for daylight saving time changes e Submit Click here to apply the new date time settings to the network camera 36 User manual SNC 670ID W GRIN El HA VIDEO TECHNOLOGES 4 4 2 Time stamp Enable Timestamp Timestamp Location Timestamp Format DD MM YYYY TITLE BOTTOM RIGHT e Enable time stamp The time stamp is displayed e Time stamp position o UPPER LEFT o UPPER RIGHT o BOTTOM LEFT o BOTTOM RIGHT e Time stamp format o YYIMM DD MM DD YY DD MM YY YY MM DD TITLE YY year DD day MM month O O O e Submit Click here to apply the new time stamp settings to the network camera 4 4 3 User admin Admin root Operator quest Viewer Add Modify User User Name Password Confirm Authority Admin Operator Viewer Tera SAN EE User manual SNC 670ID W HENAVIDEO TECHNOLOGIES e User list This list displays the user s and their respective authorisations e Delete user Select a user from the list to be deleted and click this button e User name Enter the user name here which is to be added or modified e Password Password of the above user name e Confirm Re enter and thus confirm the password here e Authority Authorisation level admin operator or viewer e Submit Click here to apply the new user settings to the network camera 4 4 4 La
38. ttern consisting of up to 16 characters Use the left right arrow to select the characters To move from left to right press ZOOM To move from right to left press ZOOM Blanks are indicated with PATTERN gt DATA FILL Indicates whether the storage location which is reserved for the current pattern is already fully used In order to set a pattern do the following e Press FOCUS e Use the arrows and the zoom button to go to the desired route e Press FOCUS to save the route PATTERN gt SAVE Saves the settings of the current pattern PATTERN gt EXIT Exit the menu 07 SAN i EE User manual SNC 670ID W EMA VIDEC TECHNOLOGIES 2 9 Alarm The camera has 4 analogue alarm inputs which can be connected with presets tours and patterns ALARM SET ALARM NO O1 lt i ALARM INPUT OFF Default setting ALARM ACT KD SAVE EXIT ALARM gt ALARM NO There are 4 alarm inputs available Use the left right arrows to select an alarm number ALARM gt ALARM INPUT The alarm inputs can be set to NC Normal Closed or NO Normal Open The default setting is OFF Use the left right buttons to select a value ALARM gt ALARM ACT If an alarm is triggered one of 165 preset positions 001 165 one of 8 tours T01 T08 or one of 8 patterns P01 P08 can be started Use the left right arrows to seelct a value ALARM gt SAVE Saves the adjustments oft he current alarm input ALAR