1. Ethernet Service FT Manager LE Configuration of escape route technology using a web browser on TSB Controller web interface TSB Controller 970 TSBC 20 Server FI Server OPC PC Interface to WINMAG WINMAG lt Monitoring and controlling E E OPC server option Hazard Management Monitoring and controlling as OPC client WebFT Visual display using For visualisazion and Server PC monitor controlling via Microsoft Client PC with MSIE Internet Explorer Repeater 901 35 exl FT Manager Connection to service PC The network connection between the TSB controller and a service PC is estab lished using a cross over cable The escape route technology is configured using FT Manager and a web browser System settings System settings on the controller such as TCP IP address assignment are made on the FT Manager web interface You will require an internet browser Internet Explorer version 7 and above Mozilla Firefox version 3 and above to use the web interface 21 Windows XP 22 Configuring the network connection You need to check the LAN settings on the network card and adjust if necessary to ensure that the TSB Controller can communicate with your PC The bus controller s DHCP server is active ex works Note The following description is valid for Windows XP in classic view The p
2. system Bus controller installation Power supply The bus controller installation location must meet the following requirements e It must be on the inside of the building e Itmust not be exposed to any unusual environmental conditions such as agressive vapours or high humidity e 970 TSBC should be easily accessible a protected area and not be exposed to direct sunlight to ensure that the buttons can be easily operated and the indicators can be seen e When mounting the 970 TSBC on the wall take care not to damage any wiring or pipes inside the wall itself The module rack for the 970 TSBC and fastening screws must not come into contact with conductive elements in the building s structure The 970 TSBC must be powered by an external power supply The power supply must deliver an output voltage between 12 V DC 10 and 30 V DC 10 and fea ture a minimum power output of 10 W The maximum permissible ripple is 50 17 View of circuit boards 18 Hinweis Die Batterie sollte bei eingeschaltetem Strom gewechselt werden da sonst die Bon Werkseinstellung supply gt Betriebsspannung 3 Datenbank gel scht wird MAC adress 12 30 V DC FT Manager htips 1 1 1 1 Ethernet Ethernet Network adress LLLI User Password ES Administrator Admin CFWUser Language 3 Er JP 1 pa E1 E2 E4 E5 Rel2 R
3. 1 1 1 and press enter Y Asecurity notice will appear Zertifikatfehler Navigation wurde geblockt Windows Internet Explorer x Es besteht ein Problem mit dem Sicherheitszertifikat der Website Das Sicherheitszertifikat dieser Website wurde nicht von einer vertrauensw rdigen Zertifizierungsstelle ausgestellt Das Sicherheitszertifikat dieser Website wurde f r eine andere Adresse der Website ausgestellt Die Sicherheitszertifikatprobleme deuten eventuell auf den Versuch hin Sie auszutricksen bzw Daten die Sie den Server gesendet haben abzufangen Es wird empfohlen dass Sie die Webseite schlie en und nicht zu dieser Website wechseln 9 Klicken Sie hier um diese Webseite zu schlie en e Laden dieser Website fortsetzen nicht empfohlen Weitere Informationen Note The security certification encrypts communication between the computer and the970 TSBC This security certification is trustworthy but the web browser won t recognise it e You will therefore need to select Continue to load this website 27 In a network 28 Erweiterte Ansicht ASSA ABLOY Y FT Manager will now open in the browser window Connection to server PC If the TSB Controller is to be used in a network you will need to coordinate with the network administrator Configuration for use in a network You can permanently assign IP addresses in a network or obtain them automatically The TSB Controller requires a perm
4. TSB Controller 970 TSBC 20 970 TSBC 20 User manual ASSA ABLOY ASSA ABLOY the global leader in door opening solutions Publisher Document number Firmware version FT Manager ver sion Issue date Copyright ASSA ABLOY Sicherheitstechnik GmbH Bildstockstrasse 20 72458 Albstadt Germany Telephone 49 0 7431 123 0 Fax 49 0 7431 123 240 Internet www assaabloy de Email albstadt assaabloy de D0057102 4 0 1220 4 0 1220 01 2011 2011 ASSA ABLOY This document and all its parts are copyrighted Any use or changes outside the strict limits of the copyright are prohibited and liable to prosecution if no prior consent is obtained from ASSA ABLOY This particularly applies to any copying translations microforms or storing and processing in electronic systems Contents Publisher 0 0eceeeeeeeee 2 Document number 2 Firmware 2 FT Manager 2 Issue 2 Copytrightbs order ee 2 General 4 Introduction lssssessssssse 4 Instructions for fitters 4 Symbols and icons used in these iriStructions u a 4 Packaging and storage 4 Intended use 5 Working on the system 5 Warranty conditions 5 Maintenance and care 5 Included i
5. anent address The required settings should be configured in FT Manager Specific values for device Dimensions and design Technical data Input voltage range 12 30 VDC 10 Max ripple of 50 Power input Max 9 7 W Protection class lIl extra low safety voltage Protection rating according to DIN 40050 IP20 Operating temperature range 0 40 Storage temperature range 25 60 Battery CR2032 Lithium coin battery 3V 210mAh Ethernet interface RJ45 Transmission rate 100 MBit s IEEE standard 802 3 100BASE TX Composite housing WxHxD 175 x 240 x 90 mm Front panel 3U HP 42 for 19 rack 29 Notes 31 and convenience 2IKON burglary pi provect people and property 25 engineering l M which provide security and conven one and ET over billion ei euros Fax 497431 123 240 www assaabloy de We reserve the right to make technical changes 00057101
6. e buttons for about 60 sec the indicator will change after about 45 sec see next line After about 45 sec hold down the On Flashes Flashes Flashes Flashes buttons for about 15 sec longer After about 15 sec On On On On On release the normal start controller buttons Ifthe buttons are released between On Flashes Flashes Flashes Flashes 45 and 60 sec quickly quickly quickly quickly Reset to factory settings interrupted As Controller start before 45 sec is up No reset to factory settings Only when network cable is connected The green LED for the Ethernet lights up or flashes during the controller start phase as well as to display the activated functions during a Reset to factory set tings operation even if the network cable is not connected 11 Indicators and functions 12 Operation indicator The Operation indicator signals that the controller is functioning e Power connected operation indicator is lit Error indicator System errors are signalled by the Error indicator Noerror error indicator off e System error error indicator lights up TSB operation The TSB operation LED signals the TS Bus functions e TSB not connected LED off e TSB operating without errors LED is lit e TSB is not configured reference operation required LED flashes e TSB malfunctioning the operation indicator and error indicator LEDs flash in parallel Ethernet operation The Ethernet o
7. e Interface for OPC and visual display of building layout e FT Manager web interface Configuration and parameterisation for systems and devices Events logging Maintenance module As a central interface the FT Manager web interface offers the system integrator the option of integrating configuration and administration functions by linking them into its user interface No special software must be installed and maintained on the computer except a standard web browser Internet Explorer 7 and above Mozilla Firefox 3 and above A service PC is directly connected using a crossover cable included in the supply package The system can also be integrated into the building network A patch cable must be used to connect to a building network not included in the supply package System security is assured thanks to password protection a backup function and encrypted transmission to the PC Note If the PC should crash the TS Bus will continue to function The doors can be controlled using an optional control panel instead If the TS Bus fails the safety functions in escape door control units or escape door control terminals and connected components such as escape door strikes and emergency open switches remain operative for safety reasons Controls and indicators General informa tion on controls Reference Operation Upload Data Save Data Fault Ethernet Operation Ext USB TSB Operation Storage Device USB Op
8. el3 Terminal connections and jumpers E1 Input functions are configured using FT Manager E2 E3 4 5 Rel 1 Output functions are configured using FT Manager Rel 2 Rel 3 JP 1 Disconnect battery Only remove when stored for a very long time to protect the battery otherwise connected at all times JP2 Tampering contact simulation bridge must be connected at all times JP3 Activates Master pull up resistance Must be permanently connected since the TSB Controller is always master 4 No function at present Wiring diagram for TSB Controller 970 TSBC 20 O O a Es Ga aa Operating voltage 2 a nn 12 30VDC Ethernet _ RJ 45 Rel 1 Rel2 Rel3 a a z o o o NN mm es eo O 0 0 0 0O O Ak Ak AA 11 qb acp ab Not used noc nc noc nc nc Hi ET png Contact in idle position 1 currentless L L Note Input and output functions are configured using FT Manager 19 Check list Turning on the system 20 Set up operation Check installation lt the power supply to the peripherals secured e Are all peripherals escape door strikes and contacts connected lt bus line connected to the peripherals lt the power supply connected to the controller e 15 the bus line connected to the controller Check the settings on the 970 TSB Controller and peripherals e Have the system setting
9. eration Operation Interface Peripherals and escape doors are controlled and monitored from the PC prefer ably using the effeff escape route visual display programme WebFT System status messages and statistics are configured and displayed on the integrated web ap plication FT Manager This is why the bus controller contains only three operator buttons LEDs for operation and system status messages and a USB port for saving and re establishing configuration settings Function buttons Start refer The reference operation is designed to scan a TS Bus s com ence operation plete address range and save the detected end devices as a reference configuration oxo Entering and saving system data Indicator functions Operation Fault TS Bus Ethernet Ext USB Green LED RedLED GreenLED GreenLED Yellow LED Reference operation On Flashes On Flashes Press down reference operation alternately alter button for about 10 sec nately Start of reference operation On On On On Button can be released Reference operation complete On On On Off Button released before 10 secisup On Flashes On quickly for 10 sec The Reference operation button can be blocked in the software 10 Note A new reference operation is required whenever new devices are added to the system or whenever devices are removed TSB 2 devices can also be added without a reference operation although they can only be removed using the web interface or per
10. forming a new reference operation Saving data The controller configuration settings are saved on an exter nal data storage device USB flash drive via the USB port The system configuration settings log data and authorisations are saved in individual files on the data storage device by pressing this button The function can be blocked in the system settings Upload data Press the button to upload the saved configuration settings from an external data storage device USB flash drive via the sen USB port and transfer them back to the controller s internal memory This function enables a data back up or a new system configuration to be imported into the system Warning The data on the controller s internal memory will be overwritten It is possible to update individual sections separately by using several files A plau sibility check is performed before data is re written If the re upload is successful the data storage device function indicator will go out if there is an error it will flash quickly for 10 seconds Reset to factory This function resets a fully configured device to its initial state setting The external memory is unaffected by the reset Reset to factory settings Indicator functions Operation Fault TS Bus Ethernet Ext USB GreenLED RedLED GreenLED GreenLED Yellow LED Reset to factory settings switch On On On On On on the power and press down the Reference operation and Read data storage devic
11. he operating instructions or in the operating instructions for individual devices It is not permitted to make any changes or additions to approved mechanical and electrical functions in devices If any changes are made any approval for operation becomes invalid Any work on electrical connections may only be carried out on the TSB Control ler and control devices when they are in a denergised state to eliminate any risk of physical injury or damage to the equipment Observe VDE regulations in this respect The warranty is only valid if control devices and connected components are used in a correct manner as intended Neither the user or installer are permitted to make any changes or interfere with equipment ASSA ABLOY Sicherheitstechnik GmbH s Terms and Conditions of Sale and Delivery apply The TSB Controller is maintenance friendly e Control devices may only be cleaned using just a soft cloth No dissolvents or cleaning agents may be used Replacing the back up battery Data is backed up using a CR2032 Lithium battery The battery must be replaced when necessary Warning of data loss When them battery is replaced data buffering is unpowered for a short time This may lead to a loss of data in the worst of cases Before changing the battery Always back up the data first Then replace the battery with the operating voltage switched on e TSB Controller 970 TSBC 20 e Cross over cable e with instructions for drivers and
12. k carefully TS Bus installation e You must install a separate shielded line which is used exclusively to connect peripherals to the bus We recommend using telecommunications cable type J Y St Y with a cross section of 0 28 mm or 0 5 mm Donotuse free wires in the bus line for additional control tasks or power sup ply to external peripherals since this may interfere with data transmission The total length of the bus line should be no longer than 1 000 m and resist ance in the line to peripherals should be no greater than 65 ohm This ensures that no problems arise due to high interconnect capacitances and resistances We recommend using Bus Repeater 901 35 for projects where longer line lengths are required e Install only one wire for the data line and one wire for ground in the bus con nection for the whole system Never connect two or more wires in parallel to increase the cross section size as this can cause malfunctions Connecting peripherals to the TS Bus Each peripheral features two connecting terminals for the TS Bus the TS Bus data connecting terminal for the data line and the TS Bus GND con necting terminal for the system ground The bus line must be connected to these terminals Ensure that the bus line is poled If the bus line is connected incorrectly it will short circuit and block the whole bus system possibly damaging connected devices permanently You should therefore take care when connecting up the
13. n delivery 5 6 General description 6 Usage and range of functions 7 Controls and indicators 8 General information on controls 8 Function buttons 9 Reset to factory setting 11 Indicators and functions 12 Installation Guide 15 Types of warning 5 15 Lines and 16 Bus controller installation 17 Power 17 View of circuit boards 18 Wiring diagram for TSB Controller 19 Set up operation 20 Checklist usa ars 20 Turning on the system 20 Network 5 21 FI Manager erret ees 21 System settings 21 Windows 22 Wind OWS E occ eene tete 24 Opening FT 27 es 28 Technical data 29 Specific values for device 29 Dimensions and design 29 onere repere yan 30 Introduction Instructions for fitters Symbols and icons used in these instructions AN Packaging and storage AN General ASSA ABLOY Sicherheitstechnik GmbH sextensive experience and state of the art production and testing procedures ensure this device is highly reliable The following ope
14. on On Flashes On Flashes Press down reference operation alternately alter button for about 10 sec nately Start of reference operation On On On On Button can be released Reference operation complete On On On Off Button released before 10 secisup On Flashes On quickly for 10 sec 14 Types of warning Installation Guide Warning The bus controller module and connected devices may only be installed and set up for operation by a qualified electrician Attention You must observe and comply with the German Electrical Engineering Association VDE and local electricity company regulations when installing equipment You must also comply with safety regulations regarding work on electrical systems Note Components at risk of electrostatic discharge Electronic components in equipment should not be touched to ensure that elec trostatic discharge does not cause injury or damage If you cannot avoid touching electronic components you should use a suitable anti static tool To ensure that the risk of electrostatic discharge is kept to a minimum the person who is working on the system should ensure that they are not carrying an electric charge They should take suitable measures such as wearing an anti static wrist strap 15 Lines and wiring 16 You must comply with a few installation requirements to ensure that the system functions correctly Please follow the instructions below and carry out installation and connection wor
15. peration LED signals an Ethernet connection operation e Connected to network LED is lit e Additional data traffic LED goes out briefly when there is a flow of data USB connection function indicator external data storage device Configuration and logging data can be stored on a USB flash drive which can be connected via the USB port provided It is also possible to upload data onto an ex ternal data storage device or re load configuration data into the system without using the web interface The LED signals when a data storage device can be removed e LEDislit data storage device cannot be removed e LED is not lit data storage device may be removed Controller start Indicator functions 7 Controller start On On On On On Changeover to system data entry after about 45 sec Begin of system data entry On On On On System data entry complete On On On Off Controller initial state On On On Device status Indicator functions Power on Network connected On On Network data traffic On Off briefly flicker TS Bus not connected On Flashesin Flashesin On or malfunctioning pair pair TS Bus OK On On On Access to data storage device On On On On Read data or upload data button activated 13 Entering and saving system data reference operation Indicator functions Operation Fault TS Bus Ethernet Ext USB Green LED RedLED GreenLED GreenLED Yellow LED Reference operati
16. rating and installation instructions contain important instruc tions information and recommendations for device installation set up and operation You must comply with these instructions to ensure that the system functions safely without any problems The symbols in these operating instructions are designed to help you use the devices and instructions quickly and safely Note This symbol indicates additional information which is useful when handling devices Warning about a general hazard This warning symbol indicates tasks where hazards may arise or device functions may be impaired due to different causes Step in procedure The specified sequence of steps will make it easier for you to use the device safely and correctly Result This indicates where the end result of a sequence of steps is described Our devices are carefully packaged to ensure adequate protection during shipment When you receive your device you must check the device and its packaging to ensure that the device is complete and undamaged Risk of injury The device must not be used if it is damaged Damaged cables and connector assemblies also represent a safety hazard and must not be used Intended use Working on the system Warranty condi tions Maintenance and care AN Included in de livery Escape door control components may only be used for their intended purpose This means that they may only be connected and operated as described in t
17. rocedure may differ depending on your operating system Open up the network and data communications connections using the sys tem controls or start menu for example Neues Office Dokument Office Dokument ffnen Programmzugriff und standards Programme Dokumente Einstellungen Suchen gt Drucker und Faxger te Hilfe und Support 182 Taskleiste und Startmen Ausf hren rodens abmelden Windows XP Professional Herunterfahren Start You now need to open up Internet protocol properties TCP IP Netzwerk und DF Verbindungen igenschaftei tprotokoll TCP IP Proceed as follows 1 In the Network and data communications connections dialogue box select LAN connection In the LAN connection status dialogue box click on Properties In the LAN connection properties dialogue box click on Internet protocol TCP IP Click on Properties In the Internet protocol properties TCP IP dialogue box select Obtain an IP Address automatically and Obtain a DNS server address automatically 23 Windows 7 24 Configuring the network connection You will need to adjust the LAN settings on the network card to ensure that the TSB Controller can communicate with your PC Note The following description is valid for Windows 7 in standard view The proce dure may differ depending on your operating system e Open
18. s been configured e Are all peripherals set to Bus operation e Has each peripheral been assigned a peripheral address Initial operation of peripheral devices 1 Switch on the power supply to each individual peripheral 2 Check each individual peripheral at its installation location to verify that it is fully functional 3 There must be no alarm active on peripherals once they are checked If an alarm is active it must first be switched off and the cause of the alarm elimi nated before continuing Initial operation of the 970 TSB Controller 1 Turn on the power supply Y green operating voltage indicator must light up after the controller is switched on 2 Switch on your PC and make the required settings in FT Manager Note We recommend using FT Manager when putting the system into operation due to the limited diagnosis options on TSB controller Network connection You need to establish a network connection between the TSB Controller and your PC so that you can access the web interface in FT Manager This can be done in several ways e Direct network connection using a cross over cable included in supply package Initial set up operation using service PC e Apatch cable to connect to a building network not included in the supply package Coordination with the network administrator required Configuration for use in the network Network structure Escape route technology network structure
19. service programmes e User manual General descrip tion Operation Bus technology is primarily used in modern control technology in equipment where a larger number of individual devices are monitored and controlled Conventional solutions for such projects involve time consuming installation work and are consequently expensive This is where bus technology is ideally suited as it doesn t have the disadvantages of a conventional installation effeff has developed a bus system using its TS Bus door control bus to meet the requirement for cost effective installation The TS Bus uses two wire technology to ensure that installation between the individual devices and a central control point is restricted to a two wire bus line The bus controller module forms a link between a PC and the TS Bus All data communication between the PC and the TS Bus passes through the Ethernet port on the PC Data communication between the bus controller module and the indi vidual escape door control units or escape door control terminals hereinafter referred to as peripherals is performed over the TS Bus Up to 110 peripherals can be controlled and monitored on the PC via the two wired bus line Usage and range of functions Use in systems with up to 110 peripherals e Minimum installation work when using effeff TS Bus e Buttons to import and save system settings e LED indicators for bus master system status messages for TSB 1 and TSB 2 devices
20. up the network and data communications connections using the sys tem controls or start menu for example G iH i Hardware Jugendschutz Leistungsinformat ES Netzwerk You now need to open up Internet protocol properties TCP IP LAN oder Hochgeschwindigkeitsinternet 2 Drahtlosnetzwerkverbindung LAN Verbindun gc Deaktiviert Nigam lt ntifiziertes Netzwerk Atheros ARSOO7EG Wireless 888057 Proceed as follows 1 Click on Manage network connections 2 Inthe Network connections dialogue box click on LAN connection 25 26 X Marvell Yukon 88E8057 PCI E Gigabit Ethemet Controller Diese Verbindung verwendet folgende Elemente Pre Antwort f r Verbindungsschicht Topologieerkennung In the LAN connection status dialogue box click on Properties In the LAN connection properties dialogue box click on Internet protocol version 4 TCP IPv4 Click on Properties As in the example using Windows XP select Obtain an IP Address automati cally and Obtain a DNS server address automatically Press I OK Accept Opening FT Man ager Once configuration is complete you can then open up FT Manager in a web browser Proceed as follows 1 Startyour web browser 2 Enter the following URL in the address bar https 1