Contents
1. 53mm 1 2Kg 150W e bike TSL 24 15 255 150 65mm 1 5Kg 450W Electric TSL 24 20 cit 200 156 75mm 2 2kg 600W orkli TSL 24 25 ones 265 155 80mm 2 8kg 750W ectric TSL 24 40 ck 335 225 110mm 5 5Kg 1200W stacker TSL 24 80 360 280 180mm 7 5kg 2500W TSL 36 2 e bike 160 90 55mm 0 5kg 90W Electric golf TSL 36 20 265 155 80mm 2 9kg 900W car electric TSL 36 25 265 155 80mm 3 kg 1125 W vehicle TSL 48 5 200 150 75mm 2 Kg 300W e motor TSL 48 10 200 150 75mm 2 2 Kg 600W Electric golf 265 155 80mm TSL 48 20 3 kg 1200W car electric 265 155 80mm TSL 48 25 3 2kg 1500W bus electric 335 225 110mm TSL 48 30 5 5kg 1800W car electric 360 280 180mm TSL 72 30 8 Kg 3600W vehicle 6 How to use 6 1 Turn on 6 1 1 First confirm the charger output voltage is suitable for the battery voltage then connect the battery to the charger confirm the pole is correct The positive pole of DC output terminal connected to the positive pole of the battery the negative pole of DC output terminal connected to the negative pole of the battery Do not anti connected please If the charger DC output is with a switch please turn on the DC output switch 6 1 2 Check the voltage of the AC input is suitable for the input voltage of the charger or not Confirm the AC input is correct turn on the power supply 6 1 3 The charger start ramp charging after auto testing in 1 minute 6 2 Indicating LED signification 6 2 1 Power indicating and battery test
2. LED It is green when connection is correct it is red when anti connection If it charges to red when charging it shows that the output line is cut loose contact Overheat protection or over current protection The charger has no output when the LED is red Please check the charger and the connection try charging again 6 2 2 Charging state LED It is red at the beginning of charging it is orange when 90 full and it is green when charging is full It is not indicate when anti connection no connection or the line cut 6 3 Turn off When the charging is full or you wait to turn off at the anytime you must turn off the charger power supply first then cut off the battery and the charger 7 operation environment 7 1 Above the sea level lt 2000m 7 2 Ambient temperature 10 C 50 C 7 3 Ambient humidity 5 70 RH 7 4 Storage temperature 10 C 60 C 7 5 Without conductive dust 7 6 Without explosive dust 7 7 Without corrosive gas and steam damaged to metal and isolator 7 8 keep away from rain and snow 7 9 Mounting slop 5 degree 8 Mounting The charger may be used as mobile charger or mounted on the equipment There is at least 100mm space between intake side and outside side Don t choke the air outlet and heat sink hole otherwise the charging function will be worse and the charger may be destroyed 9 Maintenance and service 9 1 The charger must be set at ventilated dry and dust less place to prevent the r
3. User Manual of Battery Charger Zhejiang GBS Energy Co Ltd 2009 Welcome to use our GBS series Intelligence Battery Charger Please read this manual before using the instrument Also please keep this manual with much care for future reference A ARNING Wiring precautions If failure or error of this instrument could result in a critical accident of the system install a external protection circuit to prevent such an accident In order to prevent instrument damage or failure protect the power line and the input output lines from high currents by using fuses with appropriate ratings Power supply In order to prevent instrument damage or failure supply power of the specified rating In order to prevent electric shock or instrument failure do not turn on the power supply until all of the wiring is completed Never use the instrument near inflammable gases In order to prevent fire explosion or instrument damage never use this instrument at a location where inflammable or explosive gases or vapour exist Never touch the inside of the instrument In order to prevent electric shock or burns never touch the inside of the instrument only authorized service engineers can touch the inside of the instrument to check the circuit or to replace parts High voltage and high temperature sections inside the instrument are extremely dangerous Never modify instrument In order to prevent accident or instrument failure never modify the i
4. choice from 1A to 100A by user 2 4 MCU control charging quickly based on all kinds of battery charging curve check correctly the whole process of the charge and the discharge ensuring battery full of charge 2 5 Over current over voltage overheat short circuit battery polarity anti connected protection 2 6 Adjusting voltage automatically according to weather with temperature compensation function 2 7 Design the special charging curve by user 3 technical parameter Input voltage 110VAC 220VAC 380VAC Power frequency 47 63Hz Used battery voltage 6V 12V 24V 36V 48V 72V etc Output current 1 8 3 5 8 10 15 20 25 30 40 50 80 100A Efficiency 70 85 Charge time 5hours discharge depth 50 Insulate voltage I P O P 1 5KVAC I P FG 1 5KVAC O P FG 1 5KVAC Insulate resistance Input Output lt 500MQ Battery Charger Used battery voltage v 6 12 24 36 48 72 etc Max output current A 1 8 2 3 5 10 15 20 30 100 etc Input voltage A 110VAC B 220VAC C 380VAC NO symbol for Pb Acid battery N for MH Ni battery L for Li ion battery 5 Main model and applications Model application size weight power Electric TSL 12 10 160 150 65mm 1 3Kg 180W forklift and TSL 12 15 ae 200 150 75mm 1 5Kg 280W ectric TSL 12 30 300 155 90mm 2 Kg 380W stacker e scooter TSL 24 5 190 95
5. eduction of the performance of the charger 9 2 Find the charger is not working check it please Anti connection short circuit the voltage is suitable for battery or not over heat over current Try turning on again please 9 3 If the customers find other troubles please contact us or our agent
6. nstrument Maintenance In order to prevent electric shock burns or instrument failure Only authorized service engineers may replace parts In order to use this instrument continuously and safely conduct periodic maintenance Some parts used in this instrument have a limited service life and may deteriorate over time oar N Index Introduction Main specificity Technical parameter Meaning of the model code Main model and applications How to use 6 1 turn on 6 2 indicating LED signification 6 3 turn off Operation environment 8 Mounting Maintenance and service 1 Introduction Ningbo Thunder Sky Green Power Sources Co Ltd is specialized in the study and production of the intelligence battery charger for long terms The company has passed ISO 9001 2000 quality system TSL series battery charger is based on MCU technology with pulse charging mode the charging voltage has temperature compensation automatically When charging the battery temperature rising is very small and advanced charge with heating for effectively prolonging the service life of the battery It could be used in the various electric cars the field of tourism railway mine post and telecommunication 2 Main specificity 2 1 Switching power technology with small size light weight high efficiency and full function 2 2 Suitable for 6V 12V 24V 36V 48V and 72V battery etc 2 3 Wide range of output current for