Home

Operator Plus EasyWin Plus 2.011 User Manual

image

Contents

1. Language C3 o More settings Application Hardware Printer In the top area the language of the EasyWin Plus software can be selected by pressing the button with the corresponding flag The icon 9 points out the actual selection if there are several options for choice 19 In the middle part of the dialog further setting can be made After pressing a button in that area a subsequent dialog will be shown The following sections will describe in detail the available settings in the different categories After having pressed the OK button the user will be prompted whether the changes really should be applied If the user acknowledges the settings will be kept permanently and the dialog will be closed The settings will be loaded automatically at program start The CANCEL button will close the dialog too The changes will be discarded Before there will be a security prompt too The OK and CANCEL buttons in the settings dialog will apply respectively discard all changes which were made in the subsequent dialogs too 2 8 1 General application settings With the help of the button application the following dialog for adjusting the basic behavior of the EasyWin Plus software will be opened r Application settings mm General application settings EOM The following settings can be adj
2. gwk erkzeuge amp Kalibrierung 1 y Operator Plus Easy Win Plus 2 011 User Manual GWK Norbert Gerlach GmbH amp Co KG In der Steinbach 2 55758 Schauren Phone 49 0 6786 2904860 Fax 49 0 6786 2904861 info gwkgerlach de CONTENTS 1 4 Operatine Ist ECL OBS eec oen etre ini dr teste 2 1 1 User Mere Coane aar e A dida 2 1 1 1 IP c v 2 1 1 2 Push Button Funchons General oos ea 2 122 Mens nase E 3 1 2 1 NTAINMM NUE M DEPT 3 12 2 SE UI NENU an ewig edie tind E RAN 3 1 3 Parameter prese LUSIS iia it acia 4 1 4 Other display tea dois as naar De 5 Easy Win PIS 201 did 6 2 1 Installation O 6 2 2 Main window or FasyWin PIUS uv seis dar t o o nn debat 6 2 3 Menu Database an een 7 2 4 Eundamental per tine hin a ae u u 7 2 3 Administer parameter ses 8 2 5 1 ToorpariMe ter Sel MIE na en nt EEE 9 2 252 Contisturati n litres 9 235 List of tightening patameerse aa eina Eiai 10 2 5 4 Creating and editing tightening parameter sets 10 2 5 5 Fundamental operating hints using parameter sets oooocccccconioccnnnnnnnonnnnnnnnnnns 12 2 6 Administer tiehtening Tesulis ans a en a 15 2 6 1 Fools tiehlenins TUE VIEN sn died 16 2 6 2 Ditectoby Usan asas dia tl redes 16 2 6 3 Listor Gehenna esil See ee 16 2 6 4 List of final values and statistics view 17 2 6 5 Fundamental operating hints using tightening results 17 2 Pincode and TOO AUD a ob ep 19
3. During data input the parameter set is always checked for plausibility and integrity Implausible input will be marked with red frames around the related control element If the put in data is valid there will be two buttons for taking over the input The visibility of the buttons is depending on whether the data has been changed and whether an equal parameter set already exists Description Creates a new parameter set out of the data input and appends the parameter set to the list of tightening parameters Applies the data input to the parameter set with the specified name resp to the selected parameter set Closes the parameter set editor and returns back to the parameter set administration 2 5 5 Fundamental operating hints using parameter sets In this chapter a few examples are given to demonstrate some fundamental operating methods for the tool parameterization and the handling of configurations in the parameter set administration 2 5 5 1 Configuring the tool e Create the desired parameter sets if not already existing e Select the parameter sets and insert them into the tool view This action can be executed in 3 different way with the same result o by pressing the button i o with drag amp drop o with the help of the clipboard e Repeat the above step as long as the desired composition of parameter sets is generated in the tool view The order of the parameter sets in the tool view can be adjusted
4. 2 8 visio cM SP ER 19 2 8 1 General application SCLUTIBS usa aaa 20 2 8 2 Hard Wake senine Sne nan ea eier 21 2 8 3 Pinter Se A A ae ee ernste 22 29 Into about Easy W m TUS Shen area ne ee eee 22 Datauutput Via Serial Nel ACC 522a et iii aan 23 3 1 TAC m M 23 3 2 ol AAA A ee 24 Lechnical Data zes Bu een Mu aula Mea den Rite 25 1 Operating Instructions 1 1 User Interface OPERATOR e Power Snug Torque o green tool is activated o yellow snug torque is reached aktiv meassurement e tightening status o displays 70 80 90 and 100 of achieved target value o at 100 STOP release the tool re e tightening result o green last tightening operation was OK o red last tightening operation was NOK 1 1 2 Push Button Functions general Left Right navigation and selection to leave the menu or function use the left button 2 up down setting and selection OK confirming and selecting of functions aborting a tightening process SCAN activation of the integrated barcode scanner When the LED lights up the bar code reading process was finished successfully 1 2 Menus 1 2 1 Main menu Menu items in the Maim menu SETUP Enter Setup Menu WERKZEUG INFO display wrench information a PARAMETERSATZ BETRIEB Start Parameter set usage 1 2 2 Set up menu To enter the set up menu a 5 digit pin code is needed This pin code can be selected with t
5. at any time using the buttons and Fj e Connect the tool and switch it on e Send the actual tool configuration shown in the tool view to the tool with the help of the button LA e Optionally the composition of parameter sets can be added to the configuration list by a pressing the button zs 12 2 5 5 2 Creating configurations Configurations can be created in three different ways 2 5 5 2 1 Creating configurations in the tool view The first way to create a configuration is using the tool view The method is the same as described in the above section configuring the tool The configuration can be created without having a tool within reach The steps connecting and switching on the tool and sending the configuration to the tool can be left out then 2 5 5 2 2 Creating configurations in the configuration list A further method for creating configurations is supported by the configuration list The list always contains an item new at the end You can drag amp drop here tightening parameters out of the parameter list at the right side The parameter sets will be added at the end of the configuration Finally the configuration should be renamed by a left mouse click Optionally a remark can be added in the second column 2 5 5 2 3 Creating configurations by read out from the tool Additionally a configuration can be created when a configured tool is read out with the Lu button J The tool s parameter sets will be added au
6. bringen Die durchgestrichene M lltonne bedeutet Batterien und Akkus d rfen nicht in den Hausm ll Pb Cd und Hg bezeichnet Inhaltsstoffe die oberhalb der gesetzlichen Werte liegen English Consumers are legally required to dispose of batteries at suitable collection points vending points or dispatch bays The crossed out wheeled bin means that batteries must not be disposed of in the household waste Pb Cd and Hg designate substances that exceed the legal limits French La l gislation exige des consommateurs le d p t des piles usag es dans un lieu de collecte appropri un point de vente ou un entrep t d exp dition La poubelle barr e signifie qu il est interdit de jeter les piles et les batteries avec les ordures m nag res Pb Cd et Hg d signent les substances dont les valeurs d passent les limites l gales 26 Italian Per legge i consumatori sono obbligati a depositare le batterie esaurite presso i punti di raccolta i punti di vendita o i magazzini di spedizioni Il simbolo del contenitore dei rifiuti sbarrato indica che vietato smaltire le batterie con i rifiuti domestici Pb Cd e Hg indicano le sostanze presenti con valori superiori alla norma Spanish Los usuarios est n obligados por ley a depositar las pilas viejas en un punto de recogida adecuado punto de venta centro de env o El contenedor de basura tachado significa la pilas no deben desecharse en la basura dom stica Pb Cd y Hg des
7. to import that data into other applications The data is formatted as tabulator separated text 2 6 5 Fundamental operating hints using tightening results In this chapter a few examples are given to demonstrate some fundamental operating methods for the read out of tightening results from the tool and the handling of tightening data in tightening results administration 2 6 5 1 Reading out tightening data out of the tool e Connect the tool and switch it on e Read out the content of the tool s tightening data memory with the help of the button xi After that the tool view shows all files with tightening result stored in the tool e Select the files with tightening results of interest e Read out the selected files from the tool by pressing the button This action can alternatively be carried out with a double click onto the selected entries in the tool view or via drag and drop of the selected tool view entries into the list of tightening results Before reading out the user will be asked whether the results should be deleted from the tool s memory after read out 2 6 5 2 Creating directories In order to create a new directory the directory list always contains the entry new at the end of the list The items of the list of tightening results can be put here via drag and drop The sorting sequence of the data sets in the directory will be the same as in the list of all results This means that the data sets which have
8. 6 Administer tightening results With the use of the button in the main window the following dialog for the administration of tightening results will be opened Tame esa Tea O TA EF Ee Remark No Name Results Mode LAL T ft lbs Every data set Screw 1 98 E 23 63 17 60 11 20 25 15 Insert data sets 19 22 16 49 20 91 16 66 m RERERERLAALALP ugs 1 No Name Results Mode LAL T ft Ibs 2 Screw 2 94 YPC Nominal value 20 90 3 Screw 3 110 AN Lower limit 4 16 00 6 Scew6 92 info Upper limit 25 80 Screw 8 1 AN Minimum 5 16 23 Screw 10 DTA Maximum 26 24 Screw 11 DTA Average val 5 21 723 Screw 13 DTA x 3 363 Screw 16 AN 30 0 49 G Werkzeuge amp Kalibrierung Y The window is divided into five big functional regions The related buttons are placed at the bottom margin of those regions In the bottom left area the tool view is placed After a tool has been read out the tool view displays the content of the tool s memory for tightening results and some information about the tool After the read out of the tool all sets of tightening results in the tool view are selected for further processing The top left area of the window contains the directory list The tightening results can be placed into a directory to get better clarity for the user The selection in the directory list determines the content of the list of tightening results in the top middle part of the window The list of t
9. LES Wersion 2 011 en Copyright C 2012 GWK Norbert Gerlach r GmbH amp Co KG p Werkzeuge amp Kalibrierung 22 3 Data output via serial interface 3 1 Header After starting the wrench with preset parameters a header is sent which shows the active tool number and parameter set Example Wzg Nr Dateinummer Schraubmodus Wirkrichtung Dateiname Speichermodus Anzahl Messwerte Haerte Fuegemoment Nominalmoment Momentgrenzen Nominalwinkel Winkelgrenzen Zahler 03 12345ABCDEFG TESTW_ABLAUF1 n speichernd 0005 0 Nm 0000 0 Nm 0000 0 0000 0 Nm 0045 00 0000 0 0000 0 0 If a cycle counter is activated in the parameter set it will be shown in the header Communication protocol 18 OA OD 57 7A 67 2E 2D 4E 72 2E 20 20 20 20 20 3A 20 47 OA OD 44 61 3A 20 6D 6F 64 75 73 ec 20 20 20 20 68 74 75 6E 67 44 61 74 65 69 3A 20 54 45 53 20 20 20 20 20 63 68 65 72 6D 20 73 70 65 69 61 68 6C 20 4D OA OD 20 20 20 20 20 75 65 67 65 6D 32 33 34 35 65 69 6E 75 45 46 20 62 Wzg Nr 12345ABCDEF G Dateinummer 02 Schraub modus Winke 1 Wirkric htung CW Dateiname TESTW_ABLAUF1 Spei chermodus on speichernd Anz ahl Messwerte uegemoment 0005 0 Nm Nominalmoment 0000 0 Nm Momentgrenzen 0000 0 O 000 0 Nm No minalwinkel 0045 00 Winkel grenzen 000 0 0 0000 0 0 Z hler 03 23 3 2 Final tightening data After a finished tightenin
10. been read out last will be placed at the end of the directory After having dropped the data sets the directory should be renamed This action can be carried out either by clicking with the left mouse button into the name field or by pressing the button Zi Optionally a remark can be put in 2 6 5 3 Searching for tightening results Locating certain tightening results in the list of tightening data sets can be made easier by switching the sorting criteria with a click into the related column header To locate certain tightening results from directories in the total list or vice versa the selection of those tightening data sets can help as described in the following sections 17 2 6 5 3 1 Locating data sets from a directory in the total list If one or more tightening data sets from a directory should be located in the total list of tightening results you can proceed as following e Select the relevant directory in the directory list After that the list of tightening results displays the tightening data sets of the selected directory e Now select the desired tightening data sets in the list of tightening results e Select the item all in the directory list Now the list of tightening results shows all available tightening data sets and the relevant data sets are selected to locate them easily 2 6 5 3 2 Locating data sets from the total list in a directory If one or more tightening data sets from the total list of tightening res
11. fo display Back to parameter set selection menu Display of detailed parameter set information OO a ush button functions in detailed parameter set information display screen Back to parameter set selection menu Back to the display screen of detailed parameter set information Qu 1 4 Other display readouts Tara setting e Tara setting of torque measurement tool must be free of any load Stop Nominal value or Stop value is reached stop tightening and unload the tool e amp a e Please unload the wrench completely Overload e The wrench is overloaded and must be unloaded immediately The tightening procedure is stopped Overspeed in rotation e Tightening to fast unload the tool Tightening process is aborted 2 EasyWin Plus 2 011 2 1 Installation e Generally you need to have administrator privileges for setting up the software e Before starting the installation be sure to close all currently running applications After inserting the installation data medium the setup program of EasyWin Plus will start automatically 2 2 Main window of EasyWin Plus r A EasyWin Plus Database gui EayWmPus Brator O HEET Lor Llar Fe x U 16 01 13 Status Name Description Database Opens saves creates a new or imports a database Parameter sets Administers the parameter sets and parame
12. g procedure the final torque angle results and the OK NOK evaluation will be sent Example M 0009 4 Nm W 0060 00 Z hler 03 VON 05 IO If a cycle counter is activated in the parameter set the line Z hler 4X X VON XX will be shown Communication protocol 18 4D 3D 20 30 30 30 39 2E 34 20 4E 6D 20 20 20 M 0009 4 Nm 20 OA OD 57 3D 20 30 30 36 30 2E 30 D2 OA OD 5A W 0060 00 Z EA 68 6C 65 72 20 23 30 33 20 56 4F 4E 20 23 30 ahler 03 VON 0 35 OA OD 49 4F 20 20 20 20 20 OA OD 5 10 24 4 Technical Data Power supply torque e rechargeable Lithium Ion battery 7 2 V e accuracy 1 scale calibration range 2600 mAh Type 18650 protected according to DIN ISO 6789 from 2046 to GWK Part No ABA 0030 100 e ca 13 h endurance per charging cycle e adjustable bolt centre distance e ca 7h recharging time e continuous use possible in combination with a charging tray or cable interconnection angle Temperature range e resolution 0 1 accuracy 1 absolute e 00 40 C at nominal angle of 100 Dimensions amp Weight Model length width hight weight 60 Nm 430 mm 59 mm 32 mm ca 1 kg 200 Nm 522 mm 59 mm 32 mm ca 1 4 kg 350 Nm 800 mm 59 mm 32 mm ca 2 5 kg 600 Nm 1050 mm 59 mm 38 mm ca 4 kg 800 Nm 1360 mm 59 mm 38 mm ca 5 kg all data without ratchet head German Verbraucher sind gesetzlich verpflichtet Altbatterien zu einer geeigneten Sammelstelle Verkaufsstelle Versandlager zu
13. ghtening parameter shows all available parameter sets and the relevant parameter sets are selected to locate them easily 2 5 5 4 2 Locating parameter sets from the total list in a configuration If one or more parameter sets from the total list of tightening parameter sets should be located in a configuration you can proceed as following e Select the item all in the configuration list Now the list of tightening parameter shows all available parameter sets e Now select the desired parameter sets in the list of tightening parameter sets Select the related configuration in the configuration list Now the list of tightening parameter shows the parameter sets of the selected configuration and the relevant parameter sets are selected to locate them easily 2 5 5 5 Creating macros sequencer If the feature sequencer is supported by the tool a complete configuration can be executed as a so called macro To do so a parameter set with tightening mode macro has to be placed to the first position of the tool view The name of that parameter set is taken for identifying the macro In macro mode the tool processes all subsequent parameter sets as a block which means that if the cycle counter of the actual set is completed the tool automatically switches to the next parameter set A parameter set with tightening mode macro is only allowed at the first position of the tool view otherwise the configuration is invalid 14 2
14. ghtening parameter Testemp NN M ic n Tightening parameter Configuration GWK Demo 60er Rep Mode LAL ANom UAL TSnug LIL TNom U 1 AN 33 0 2 00 1 AN 66 0 2 00 100 GRAD SEAE 1 TQ 2 00 60 NM 60 00 ANom UAL 85 0 27 0 Sorrow 19 4 ga LEERE The window is divided in three big functional regions The corresponding buttons are placed at the bottom part below the regions In the bottom half of the window there is the tool view After a tool has been read out the tool view shows the actual tool configuration tool parameter sets and some information about the tool In addition to that display function the tool view is the place where the parameter sets for a new tool configuration will be arranged At the top left side of the window the configuration list is placed A configuration is a group of parameter sets The selection in the configuration list determines the content of the parameter set list in the top right part of the screen The list of parameter sets displays either all available tightening parameter sets or only the parameter sets of the selected configuration depending on the selected item in the configuration list 2 5 1 Tool parameter set view m Reads out the actual tool configuration and information about the tool and shows that data in the tool view Parameterizes the tool with the actual content of the tool view Creates a report out
15. h the help of this item a new directory can be created simply by renaming that entry The items in the list of tightening results can be related via drag and drop exactly to one directory With this feature the sets of tightening results can be combined to a group The intension is to get more clarity for the user Deleting a directory can be executed alternatively by pressing the key DEL if the directory list is focused 2 6 3 List of tightening results Reads out the sets of tightening result which are selected in the tool view out of the tool s memory and appends them as new entries to the list of tightening results Before reading out the user will be asked whether the results should be deleted from the tool s memory after read out Deletes the selected sets of tightening results irrevocably out of the list of tightening results 3 Creates a report out of the selected set of tightening results J The read out of the selected tightening data from the tool can alternatively be carried out with a double click onto the selected entries in the tool view or via drag and drop of the selected tool view entries into the list of tightening results Deleting a set of tightening results can be executed alternatively by pressing the key lt DEL gt 1f the list of tightening results is focused 16 2 6 4 List of final values and statistics view Copies the actual list of final values and the statistics view into the clipboard
16. he EasyWin Plus Software Menu items in the Set up menu SETUP CODE Activation of optional special functions and service functions of the tool 20 VOLUME SETTING adjust volume level of the acoustic signal CONTRAST SETTING adjust the display contrasts 1 3 Parameter preset usage 1 3 1 1 Parameter set up using Easy Win Plus software Werkzeug ist nicht parametriert Werkzeuginfo einlesen Werkzeug parametrieren 1 Parametersatz gestartet een functions during parameter preset usage 1 Back to main menu An active tightening process will be stopped and aborted without displaying any tightening results Enter parameter set selection An active tightening process will be stopped and aborted without displaying any tightening results Termination of an active tightening process Tightening results will be displayed Tara setting if tool is not in an active tightening procedure 1 3 1 2 Selecting an using a parameter set Ausgew hlter qd gestartet Parametersatz Auswahl Parametersatz Informationen Erweiterte Parametersatz Informationen qe Verschraubung ausgewahlter Parametersatz Ergebnis ausgew hlter Parametersatz Push button functions in parameter set selection menu Y Back to start of the last selected parameter set the actual selection will be aborted Display of parameter set information Selection of a parameter set Star the selected parameter set usn button functions in parameter set in
17. hich are described in the following sections will offer you different ways to execute the available actions At one hand there will be buttons They will only appear when the corresponding action is possible This means that visibility of a button is depending on the availability of the related action At the other hand the list views will offer context menus which can be opened by clicking the right mouse button within the list views The menus will show the available actions as separate menu items The icons in front of the menu items are the same as shown on the buttons related to the same action The menu in content will be adapted just as the visibility of the buttons to the ESPN oe x s 7 Remove from configuration availability of the corresponding actions At right an example for a JM 4 Copy context menu is pictured Additionally some of the list views support drag amp drop so there are certain actions which can be executed by dragging and dropping the list view items To improve clarity in list views with many items and to help locating certain list view items the most part of the list views support changing the sorting sequence by clicking on the column headers with the left mouse button Then the list view will be sorted alphabetically by the item of the clicked column 2 5 Administer parameter sets Pressing the button administration Jin the main window opens the tightening parameter set Ti
18. ightening results displays either the total pool of tightening results or only the sets of tightening results which are related to the selected directory depending on the selection in the directory list At the right part of the window the list of final values and the statistics can be found They show the details of the selected set of tightening results 15 2 6 1 Tool s tightening result view Reads out the content of the tool s memory for tightening results and displays the tool information in the tool view Deletes the tightening results which are selected in the tool view directly from the tool s memory The tool view shows immediately after tool read out the content of the tool s memory for tightening results This information provides the starting point for further read out of the tightening data The data sets of interest can be selected and then they can be read out and added to the list of tightening results with the use of the methods which are described later in this section 2 6 2 Directory list x Renames the selected directory so that a new name can be assigned Deletes the selected directory Only the composition is deleted the contained tightening results will still remain in the list of all tightening results The directory list always contains the item all as first item to display the total pool of tightening results At the end of the directory list the item new is always present Wit
19. ignan sustancias que se encuentran por encima de los valores establecidos por ley 27 wk Werkzeuge Kalibrierung GWK Norbert Gerlach GmbH amp Co KG In der Steinbach 2 55758 Schauren Phone 49 0 6786 2904860 Fax 49 0 6786 2904861 info gwkgerlach de
20. l pressed the left button down After that the EasyWin Plus software will minimize to make the selection of another application easier If necessary another application can be brought into the foreground by moving the mouse over the task bar entry of that application To import the data simply release the mouse button after having reached the desired insert position 18 2 7 Pin code and tool number By pressing the button in the main window you will get into the following dialog for setting up a tool security code and a tool number s Pin code and tool number Tool settings Pin code 00000 Tool number 123456789012 The edit field pin code allows to specify a five character long security code Only numerical characters are allowed This code is used by the tool to protect some of its special functions The field tool number is to receive a tool specific number This number can be up to 12 characters long Non numerical characters are allowed The tool number is appended to all of the tightening results of that specific tool After having opened the dialog first the number should be read out to prevent the number from an accidentally change field The pin code is not read out 2 8 Settings With the help of the button in the main window different settings of the EasyWin Plus software can be adjusted The following dialog will be opened Settings
21. of the actual tool view This action is only available if the content of the tool view is equal to the actual tool configuration That means that there shouldn t have been any changes after the read out or the parameterization of the tool 7 Deletes all the selected parameter sets from the tool view kd Deletes all parameter sets from the tool view the entire content i t Moves the selected parameter sets one position upwards in the tool view The fi il account when having selected a different sorting sequence other than by number 1 Moves the selected parameter sets one position downwards in the tool view vi CE Pastes the parameter sets which have been copied into the clipboard in the tool ii view The inserting position will be in front of the actually selected parameter set position of the parameter set is related to its number This should be taken into The tool view is able to receive via drag amp drop on the one hand certain selected parameter sets from the list of tightening parameters and on the other hand a complete configuration out of the configuration list To do so simply drag the objects of interest into the tool view and drop them at the desired position Deleting a parameter set from the tool view can alternatively be executed by pressing the key lt DEL gt if the tool view has the focus 2 5 2 Configuration list Creates a new configuration out of the actual tool view with a copy of its c
22. ontent The name of the configuration will be selected automatically for renaming immediately after creating the configuration so that a new name can be specified Copies the selected configuration into the tool view This action is the first step to configure the tool with an already existing configuration Deletes the selected configuration Only the composition of parameter sets is deleted but the contained parameter sets will still be found in the list off all available parameter sets The configuration list has always the entry all as the first item This entry is for displaying the pool of all parameter sets The entry new can always be found as the last item of the configuration list With the help of this item a new configuration can be created simply by renaming it The individual configurations are able to receive parameter sets out of the list of tightening parameters via drag amp drop With this feature you can compose parameter sets to a configuration without using the tool view as intermediate step Deleting a configuration can alternatively be executed by pressing the key DEL if the configuration list has the focus 2 5 3 List of tightening parameter sets Deletes the selected TA sets respectively remove the selected parameter sets from the configuration depending on the selection in the configuration list y E Opens the parameter set editor for changing the parameters of the selected tightening
23. parameter set Copies the selected parameter sets into the clipboard After that the sets can be ki pasted in the tool view This procedure is an alternative way to drag amp drop gt Hides those parameter sets which are not suitable for the read out tool This action 7 is only available after having read out valid tool information and if there are all parameter sets selected in the configuration list A Switches the display in a way that all parameter sets are shown even those which i are not suitable for the red out tool Those sets are marked with a gray background color A parameter set can only be deleted completely if all parameter sets are displayed no configuration selected in the configuration list If a configuration is selected the parameter set will only be removed out of the configuration but it will still remain in the list of all parameter sets If a parameter set should be deleted completely and if that parameter set is used in at least one configuration there will be a prompt that the set is used in configurations If the deleting is confirmed the parameter set will be deleted itself as well as it will be removed out of all configurations in which it is contained Deleting a parameter set respectively removing a parameter set from a configuration can alternatively be executed by pressing the key DEL if the list of tightening parameters has the focus Editing a paramete
24. port number then contains the detected value The detection of the tool interface is only carried out for the port number range from 1 up to 99 Please make sure that the serial interface for the tool communication of your system is placed inside that range device manager Always use the same USB connector of your system please Changing the USB connector could lead to a different interface assignment After having changed the interface assignment a new setting for the port number respectively a redetection of the port number is necessary 2 2 8 3 Printer settings With the help of the button lt printer gt the following dialog for setting up the printer selection can be opened a Printer settings ES Printer selection E If the option lt select before printing is enabled every time before a print out will be done a dialog for selecting a printer will be shown If this option is disabled the button default can be used to configure the printer selection in a way that the Windows default printer is used for the print out If the default printer isn t selected the combo box under it allows to select a certain printer that will be used for print out without any prompt before 2 9 Info about EasyWin Plus The button in the main window opens the following dialog to show some information about the application Info about EasyWin Plus Operator 3 EasyWin Plus Plus Q
25. r set can alternatively be started with a double click on the corresponding item in the list of tightening parameters 2 5 4 Creating and editing tightening parameter sets With the help of the button a new parameter set can be created The parameters of an existing set can be changed by pressing the button Both actions will open the parameter set editor 10 r X Edit the tightening parameter Test ewp 4 o c m E00 XR Re Tightening parameter Every parameter set No Name Rep Mode ANom UAL TSnug LIL TNom UTL Unit Dir Mem PTD Jon AN 3 116 60ML1 1 5 00 6 00 Nm CCW On 117 60ML2 1 T 5 00 6 00 N m m Data of the tightening parameter set Torque N m UTL 300 Tightening mode Pull to mark M Memory mode Direction Store data cw Torque Nm Pre tightening detection Unit Off y N m y TSnug Tolerance limits Centre dist mm Repeat On y 1 TLoos Barcode Angle Code 8 In the top part of the window the list of all parameter sets can be found Here you can get an overview of all parameter sets in stock The edit fields and the drop down lists in the bottom half give the possibility to work on the data of a certain parameter set If the editor has been opened to edit an existing parameter set this set is selected in the list of tightening parameters and the data of the set is written to the related control elemen
26. terizes the tool Tightening results Reads out and administers the tightening results Pin code Sets up the tool number and the pin code Settings Configures EasyWin Plus Info Displays information about EasyWin Plus 2 3 Menu Database Before starting to work with the EasyWin Plus software you should select an existing database or create a new database for storing the tightening parameter sets and the results The last database which has been in use will be opened automatically at the startup of EasyWin Plus The menu database offers the following options Item Description New Creates a new empty database on the storage medium The existing tightening parameter sets and results will not be copied to the new database Opens an existing database which has been saved on the storage medium before The existing tightening parameter sets and results are copied to a new database which will be saved on the storage medium then Import Imports an EasyWin Plus V1 011 database mdb from a storage medium After having imported the data EasyWin Plus will prompt you to save the database with the new format Data changes parameter sets or results will be saved automatically in the actual database when closing the particular editor window So in normal use there is no need to execute the data storage manually 2 4 Fundamental operating hints The administration windows for the tightening parameter sets and results w
27. tomatically at the end of the tightening parameter set list if they are not already contained in the list Pressing the button will create a new configuration out of the tool view 2 5 5 3 Transferring configurations to the tool e Select the desired configuration in the configuration list e Copy the selected configuration into the tool view with the help of the button This step can alternatively be executed via drag amp drop e Connect the tool and switch it on e Transfer the configuration with the button into the tool 2 5 5 4 Searching for parameter sets Locating certain parameter sets in the tightening parameter list can be made easier by switching the sorting criteria with a click into the related column header To locate certain parameter sets from configurations in the total list or vice versa the selection of those parameter sets can help as described in the following sections 13 2 5 5 4 1 Locating parameter sets from a configuration in the total list If one or more parameter sets from a configuration should be located in the total list of tightening parameter sets you can proceed as following e Select the relevant configuration in the configuration list After that the list of tightening parameter sets displays the parameter sets of the selected configuration e Now select the desired parameter sets in the list of tightening parameter sets e Select the item all in the configuration list Now the list of ti
28. ts If the editor has been opened for creating a new parameter set the control element will contain default values By double click on a parameter set in the list the data of this set will be shown in the control elements The symbolic graph on the right side of the window illustrates the different parameters The number of parameters will change depending on the selected tightening mode field and the selection of tolerance limits In the edit field repeat a tightening counter can be specified With the default setting 1 the cycle counter is deactivated If the counter is set to a value greater than 1 up to 99 the counter is enabled Then the tool will display the actual counter value After each OK sub cycle the counter will be incremented until the repetition counter 1s equal to the value of this parameter Then the repetition counter is automatically reset back to 1 to start a new cycle The tightening cycle can be aborted or reset at any time by pressing the Start OK button for at least 3 seconds 11 With the help of the field Centre dist the use of special ratchet equipment or screw attachment can be taken into account when creating parameter sets max 250mm If the field is empty the tool s standard value will be used That value is stored fixed in the tools memory and it represents the centre distance of the standard ratchet 18 mm up to Operator 100 25 mm for Operator 200 and above
29. ults should be located in a directory you can proceed as following e Select the item all in the directory list Now the list of tightening results shows all available tightening data sets e Now select the desired tightening data sets in the list of tightening results e Select the related directory in the directory list Now the list of tightening results shows the tightening data sets of the selected directory and the relevant tightening data sets are selected to locate them easily 2 6 5 4 Exporting tightening data The actual list of final values and the statistics view selection in the list of tightening results can be exported to other applications via two different ways Both methods will offer the content of the final value list and the statistics view in text format separated through tabulators 2 6 5 4 1 Exporting via the Windows clipboard With the help of the button the actual content of the finals value list and the statistics view is copied into the Windows clipboard The application which should receive the data then offers the option paste to insert the data out of the clipboard 2 6 5 4 2 Exporting via drag amp drop Alternatively it is possible to export the actual content of the final value list and the statistics view to another application via drag amp drop To do so simply press and hold the left mouse button over any entry of the final value list or the statistics view Then move the mouse having stil
30. usted pd text will be displayed as a small window message box Remind not stored If the tool view is containing a configuration that is not yet stored and configurations if that configuration would be discarded e g through a newly read out of the tool or through closing the parameter administration there will be security prompt before 20 2 8 2 Hardware settings The button hardware opens the following dialog to specify the communication port settings 3 Hardware settings Port number Search now y E This dialog is for adjusting the port number of the RS 232 interface for the tool communication The right setting for the tool interface is essential for the successful parameterization of the tool and the read out of tightening data from the tool as well as the setting up of the tool number and the tool s pin code If the option always detect is enabled there will be a search for the actual tool interface before any tool communication In order to save the time for the detection the tool interface can be adjusted to a fix value Then please take the recommendation at the end of this section into account The button search now can support you when setting the tool interface to a fix value If the tool is connected and switched on with the help of that button the tool can be detected once If the detection is successful the edit field for the

Download Pdf Manuals

image

Related Search

Related Contents

EnGenius EOC1650  クリーンドライ(温風タイプ)  MANUAL DEL USUARIO  Fujitsu FS-1004MU User's Manual  LBT-HF100C2 シリーズ 取扱説明書  Samsung Galaxy S II NFC  取扱説明書 パイプファン  全頁(PDF 3.81MB)  Manual_Motosierra 45ccy50cc  

Copyright © All rights reserved.
Failed to retrieve file